Data sheet ACT20P ACT20P-BRIDGE-S Weidmuller Interface GmbH & Co. KG Klingenbergstrae 26 D-32758 Detmold Germany Fon: +49 5231 14-0 Fax: +49 5231 14-292083 www.weidmueller.com Product image ACT20P: The flexible solution * Precise and highly functional signal converters * Release levers simplify handling General ordering data Type Order No. Version GTIN (EAN) Qty. ACT20P-BRIDGE-S 1067250000 Measuring bridge converter, Resistance measuring bridge, 0(4)-20 mA 4032248820856 1 pc(s). Creation date November 7, 2020 10:59:04 PM CET Catalogue status 23.10.2020 / We reserve the right to make technical changes. 1 Data sheet ACT20P ACT20P-BRIDGE-S Weidmuller Interface GmbH & Co. KG Klingenbergstrae 26 D-32758 Detmold Germany Fon: +49 5231 14-0 Fax: +49 5231 14-292083 www.weidmueller.com Technical data Dimensions and weights Width Height Depth Net weight 22.5 mm 119.2 mm 113.6 mm 176 g Width (inches) Height (inches) Depth (inches) 10...90 %, no condensation -40 C -40 C -40 C...85 C Operating temperature, max. Storage temperature, max. Operating temperature 543 Years Lead 7439-92-1 Listing no.: E256486 Sensor Input measurement range Bridge sensitivity 0.886 inch 4.693 inch 4.472 inch Temperatures Humidity Operating temperature, min. Storage temperature, min. Storage temperature 70 C 85 C -40 C...70 C Probability of failure MTTF Environmental Product Compliance REACH SVHC Rated data UL UL certificate Input Number of inputs Sensor supply Bridge supply voltage 1 120 mA @ 10 V (= 4 x 350 bridge resistors) 5 V or 10 V Resistance measuring bridge, Total resistance of all parallel resistance measuring bridges: min. 87 10 mV / 20 mV / 30 mV / 50 mV (adjustable) 1.0 mV / V to 5.0 mV / V Output Type Output current Load impedance current Voltage and current output (configurable) 0...22 mA (adjustable) 600 Output voltage, note load impedance voltage 0...11 V (adjustable) 600 General data Configuration Long-term drift Rail Step response time Voltage supply DIP switch and button 0.1 % / 10.000 h TS 35 < 400 ms (10...90 %) 10...60 V DC Linearity Power consumption Repeat accuracy Temperature coefficient Typically 0.05 % of signal range 3 W @ 24 V DC 0.05 % of final value typ. 0.005 % / C Creation date November 7, 2020 10:59:04 PM CET Catalogue status 23.10.2020 / We reserve the right to make technical changes. 2 Data sheet ACT20P ACT20P-BRIDGE-S Weidmuller Interface GmbH & Co. KG Klingenbergstrae 26 D-32758 Detmold Germany Fon: +49 5231 14-0 Fax: +49 5231 14-292083 www.weidmueller.com Technical data Insulation coordination EMC standards Pollution severity Surge voltage category EN 61326 2 III Insulation voltage Rated voltage 5.7 kV (input / output, input / supply) 300 Veff Output (analogue) Type (analogue output) Voltage and current output (configurable) Connection data Type of connection Tightening torque, max. Clamping range, min. Wire connection cross section AWG, min. Screw connection 0.6 Nm 0.5 mm AWG 26 Tightening torque, min. Clamping range, rated connection Clamping range, max. Wire connection cross section AWG, max. 0.4 Nm 2.5 mm 2.5 mm ETIM 7.0 eClass 9.1 EC002653 27-21-01-90 AWG 12 Classifications ETIM 6.0 eClass 9.0 eClass 10.0 EC002653 27-21-01-20 27-21-01-20 Product information Product information The ACT20P-BRIDGE-S bridge measuring transducer converts measuring bridge voltages into standard signals. Buttons are used for adjustment to the measuring bridge connected. The bridge measuring transducer can supply up to 4 parallel-connected measuring bridges each with 350. The device supports simple compensation of the tare weight with a separate input for an external button or an external PLC signal. The power supply is electrogalvanised and isolated from the input and output (3-way isolation). Properties * 4-wire and 6-wire measurement * Supply of up to 4 parallel-connected measuring bridges each with 350 * Input and output ranges can be adjusted via DIP switches * Tara compensation via external button or PLC signal * Operating status display on a front panel LED * Galvanic 3-way isolation between input, output and supply. Approvals Approvals Approvals ROHS CULUS; Conform Creation date November 7, 2020 10:59:04 PM CET Catalogue status 23.10.2020 / We reserve the right to make technical changes. 3 Data sheet ACT20P ACT20P-BRIDGE-S Weidmuller Interface GmbH & Co. KG Klingenbergstrae 26 D-32758 Detmold Germany Fon: +49 5231 14-0 Fax: +49 5231 14-292083 www.weidmueller.com Technical data Downloads Approval/Certificate/Document of Conformity Brochure/Catalogue Engineering Data Engineering Data Software User Documentation Declaration of Conformity CAT 4.1 ELECTR 16/17 EN EPLAN, WSCAD STEP DIP switch configuration tool Quickstart_german.pdf Instruction sheet Creation date November 7, 2020 10:59:04 PM CET Catalogue status 23.10.2020 / We reserve the right to make technical changes. 4 Data sheet ACT20P ACT20P-BRIDGE-S Drawings Weidmuller Interface GmbH & Co. KG Klingenbergstrae 26 D-32758 Detmold Germany Fon: +49 5231 14-0 Fax: +49 5231 14-292083 www.weidmueller.com Electric symbol Dimensioned drawing example for DIP switch setting (with ACT20 tool) Creation date November 7, 2020 10:59:04 PM CET Catalogue status 23.10.2020 / We reserve the right to make technical changes. 5