www.clare.com
2R08
LCC120
Absolute Maximum Ratings are stress ratings. Stresses in
excess of these ratings can cause permanent damage to
the device. Functional operation of the device at conditions
beyond those indicated in the operational sections of this
data sheet is not implied.
Absolute Maximum Ratings @ 25ºC
Parameter Min Max Unit
Blocking Voltage - 250 VP
Reverse Input Voltage - 5 V
Input control Current - 50 mA
Peak (10ms) - 1 A
Input Power Dissipation 1- 150 mW
Total Power Dissipation 2- 800 mW
Isolation Voltage, Input to Output 3750 - Vrms
Operating Temperature -40 +85 ºC
Storage Temperature -40 +125 ºC
1 Derate linearly 1.33mW/ºC.
2 Derate linearly 6.67mW/ºC.
Parameter Conditions Symbol Min Typ Max Units
Output Characteristics
Load Current
Continuous, AC/DC Confi guration - IL- - 170 mA
Peak t=10ms ILPK - - 400
On-Resistance, AC/DC Confi guration IL=170mA RON -1620
Ω
Off-State Leakage Current VL=250VPILEAK --1µA
Switching Speeds
Turn-On IF=10mA, VL=10V ton --5
ms
Turn-Off toff --5
Output Capacitance VL=50V, f=1MHz COUT -50-pF
Input Characteristics
Input Control Current IL=170mA IF- - 10 mA
Input Dropout Current - IF0.4 0.7 - mA
Input Voltage Drop IF=10mA VF0.9 1.2 1.4 V
Reverse Input Current VR=5V IR--10μA
Common Characteristics
Capacitance, Input to Output - CI/O -3-pF
Electrical Characteristics @ 25ºC