VER24 Series AC-DC Power Supplies
Output
Characteristic Minimum Typical Maximum Units Notes & Conditions
Output Voltage 12 24 V See Models and Ratings table
Minimum Load 0ANo minimum load required
Start Up Delay 4s
Start Up Rise Time 30 ms
Hold Up Time 10 ms Full load and 100 VAC
Total Regulation 5%See Models and Ratings table
Transient Response 4 % deviation Recovery within <1% within 500 µs for a 60% step load
change at 0.15 A/µs
Ripple & Noise 150 mV pk-pk Measured with 20 MHz bandwidth and 47 µF electrolytic in
parallel with 0.1 µF ceramic capacitor
Short Circuit Protection Continuous, trip and restart (hiccup mode) with auto recovery
Temperature Coefficient 0.05 %/ ˚C
xxx Series
www.xppower.com
1
Models & Ratings
Notes
1. Other output voltages available, contact sales for details. 2. Total regulation includes initial set accuracy, line and load regulation.
Dimensions:
VER (body only):
3.54 x 1.69 x 1.68” (90.5 x 42.0 x 42.7 mm)
24 Watt
Output Power Output Voltage Output Current Total Regulation(2) Output Connector Model Number
24 W
12.0 V 2000 mA 5% 5.5 x 2.1 x 12 mm DC Jack VER24US120-JA
15.0 V 1500 mA 5% 5.5 x 2.1 x 12 mm DC Jack VER24US150-JA
18.0 V 1320 mA 5% 5.5 x 2.1 x 12 mm DC Jack VER24US180-JA
24.0 V 1000 mA 5% 5.5 x 2.1 x 12 mm DC Jack VER24US240-JA
• Energy Efficiency Level VI
• European CoC Tier 2
• Interchangeable Mains Connectors Included
• Universal Input
• Output Voltages from 12 V to 24 V
• Class II Construction
• Low Cost
Input
Characteristic Minimum Typical Maximum Units Notes & Conditions
Input Voltage 90 264 VAC
Input Frequency 47 63 Hz
Input Current 0.6 A 100 VAC
Inrush Current 60 A 240 VAC, cold start at 25 °C
Power Factor EN61000-3-2, class A
No Load Input Power 75 mW
Input Protection Internal T1.0A/250 VAC fuse
The VER24 series of wall plug adaptors comply with the very latest energy efficiency VI standards
with high active mode efficiency and extremely low no load power consumption. Available with a
standard jack plug connector these adaptors suit a wide variety of cost sensitive applications while
maintaining industry leading performance.