CSM_M7F_DS_E_10_1
1
Digital Display
M7F
A Series of Three- to Five-digit Digital
Display Units with a Character Height of
14 mm. Models available with either red or
green displays.
Red or green displays with a character height of 14 mm are
available for a variety of applications and locations.
Miniature design with a 50-mm depth.
Incorporating a connector, thus saving wiring effort.
Connecting to OMRON's PLCs via dedicated PLC cables (sold
separately).
Units and minus symbols are displayed (three- and four-digit
model only).
Incorporating a zero suppression function.
The power supply can freely change between 12 and 24 VDC.
CE Marking. UL certification approval.
Model Number Structure
Model Number Legend
Construction and Nomenclature
Nomenclatures
12345
M7F-@@@@@
1. No. of Numeral Display Digits
(No. of 7-segment LED Indicators)
2. Input Method
3. LED
4. Display Color
5. Display Contents
Note: 1. The input type for the five-digit model is dynamic only.
2. Dynamic input is available with the four-digit model as well as the five-
digit model.
3. The minus symbol and units are available with three and four-digit
models only.
4. Three-digit models with numerals only are not available.
Code No. of digits
33 digits
44 digits
55 digits
Code Input Method
PStatic positive logic
NStatic negative logic
DDynamic
Code Character Height
114 mm
Code Color
RRed
GGreen
Code Display Contents
FNumerals and minus symbol
TNumerals and units
None Numerals only
DIP Switch
I/O Connector (OMRON's XG4A-2031)
Connect 12 to 24 VDC.
Seven-segment LED
Character height: 14 mm
Color: Red or green
Character: Numerals only
Numerals and minus symbol (for three- and four-digit models only)
Numerals and units (for three- and four-digit models only)
Power Supply Terminal
Use with OMRON's XG4M-2030-T, XG5M-2032-N, XG5M-2035-N or
equivalent socket.
Connected to OMRON's PLCs with ease by using OMRON's
G79-@C, G79-Y@C, or G79-O@C-@ Cable. Refer to page 3 for details.
Used for decimal point and negative value settings.
Refer to page 6 for details.
M7F
2
Ordering Information
Connectable PLCs
: Connectable (See note 1.)
×: Not connectable
Note: 1. External resistance not required
2. Refer to External Connections on page 9 for details.
Compatibility with OMRON PLCs (Examples)
List of Models
No. of
digits
Appearance Display
color
Input
method
Logic Display contents Model
3 Red Static Positive Numerals and minus symbol M7F-3P1RF
Numerals and units M7F-3P1RT*
Negative Numerals and minus symbol M7F-3N1RF
Numerals and units M7F-3N1RT*
Green Static Positive Numerals and minus symbol M7F-3P1GF
Numerals and units M7F-3P1GT*
Negative Numerals and minus symbol M7F-3N1GF
Numerals and units M7F-3N1GT*
4 Red Static Positive Numerals only M7F-4P1R
Numerals and minus symbol M7F-4P1RF
Numerals and units M7F-4P1RT*
Negative Numerals only M7F-4N1R
Numerals and minus symbol M7F-4N1RF
Numerals and units M7F-4N1RT*
Dynamic Positive Numerals only M7F-4D1R
Numerals and minus symbol M7F-4D1RF
Numerals and units M7F-4D1RT*
Green Static Positive Numerals only M7F-4P1G
Numerals and minus symbol M7F-4P1GF
Numerals and units M7F-4P1GT*
Negative Numerals only M7F-4N1G
Numerals and minus symbol M7F-4N1GF
Numerals and units M7F-4N1GT*
Dynamic Positive Numerals only M7F-4D1G
Numerals and minus symbol M7F-4D1GF
Numerals and units M7F-4D1GT*
5 Red Dynamic Positive Numerals only M7F-5D1R
Green Dynamic Positive Numerals only M7F-5D1G
Accessories
(Order Separately)
Unit Plate
Choose the required unit plate from the
following tables in order to attach it to the
Unit Display Unit.
Unit Plates are replaceable.
Ten Unit Plates are sold as a set. (The
number per set is the same for all models.)
The characters are white.
Display
contents
Single item (sheet only):
1 Set of 10 sheets
M7F-1
M7F-RPM-1
M7F-PER-1
M7F-KG-1
M7F-MM-1
M7F-M-1
M7F-DOC-1
M7F-PCS-1
Blank
display
rpm
%
kg
mm
m
°C
pcs
M7F model PLC's output method
Static output Dynamic
output
Input Logic input PNP output NPN output
Static Positive ××
Negative ××
Dynamic ××
PLC Output Unit M7F model
CS1W-OD211
C200H-OD215/218/219
C500-OD213
CQM1-OD213
M7F-@N@@
CS1W-OD212
C500-OD212
M7F-@P@@
C200H-OD215 M7F-@D@@
M7F
3
Cables
Use the following cables and connectors to connect the M7F to the PLC or other devices.
Model name Application Appearance Ordering Information
G79-@C
Cable with
Connectors
(1 to 1)
Connects the M7F
and a single device.
Applicable PLC
Output Units:
C500-OD415CN,
C200H-OD215, and
C200H-MD215
(Output Units
incorporating a 24-pin
connector each)
G79-O@C-@
Cable with
Connectors
(1 to 2)
Connects the M7F
and two devices.
Suitable Output Units:
C500-OD213,
C200H-OD218,
C200H-OD219,
CQM1-OD213,
CS1W-MD261,
CJ1W-OD231, and
CJ1W-OD261
(Output Units
incorporating a 40-pin
connector each)
G79-Y@C
Cable with
Crimp-style
Te r m i n a l s
Ideal for the
connection of the M7F
to devices
incorporating screw
terminals.
Suitable Output Units:
CS1W-OD211,
CS1W-OD212,
C200H-OD212, and
C500-OD412
L
PLC
OMRON's
XG4M-2030-T
M7F
OMRON's C500-CE243
(Fujitsu's FCN-36@@040
Series)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
1
2
3
4
5
6
7
8
9
10
11
12
1
2
3
4
5
6
7
8
9
10
11
12
O
n the PL
C
Connector pin No.
M7F Connector
pin No.
(Line A Line B)
Triangular mark
G79 cable
with connector (1 to 1)
Polarit
y
guide
Connection
Note: The connector pin numbers are
shown from the crimped sides of
the connectors.
L Dimensions Model
1,000 mm G79-100C
1,500 mm G79-150C
2,000 mm G79-200C
3,000 mm G79-300C
5,000 mm G79-500C
Straight length (with no bend)
a
PLC
OMRON's
XG4M-2030-T
M7F
OMRON's C500-CE403
(Fujitsu's FCN-36@@040
Series)
b
L Dimensions For output
AB Model
1,000 mm 750 mm G79-O100C-75
1,500 mm 1,250 mm G79-O150C-125
2,000 mm 1,750 mm G79-O200C-175
3,000 mm 2,750 mm G79-O300C-275
5,000 mm 4,750 mm G79-O500C-475
L
300
Device
side
OMRON's
XG4M-2030-T
M7F
L Dimensions Model
1,000 mm G79-Y100C
1,500 mm G79-Y150C
2,000 mm G79-Y200C
3,000 mm G79-Y300C
5,000 mm G79-Y500C
M7F
4
Specifications
Applicable EN Standards
Ratings
Note: Use an NPN open collector for the output of the connection
device. The data signal, however, is positive logic and the
strobe signal is negative logic.
Characteristics
Note: Impulse conditions:
Rise time: 1 ns +10% max.
Pulse width: 100 ns, 1 µs
Frequency: 100 Hz
Polarity: Positive or negative
Cable: OMRON's G79-100C
Standards
EN61326
EN60529
UL61010-1
Rated power supply 12 to 24 VDC
Allowable voltage fluctuation range 90% to 110% of rated voltage
Current consumption 200 mA max. (at 12 VDC)
100 mA max. (at 24 VDC)
Input level Static
input
Positive High: 9.6 V to power supply voltage
Low: 0 to 3 V
Negative High: 4 V to power supply voltage
Low: 0 to 1.5 V
Dynamic
input
Positive
(See note.)
High: 4 V to power supply voltage
Low: 0 to 1.5 V
Ambient temperature Operating: 10 to 55°C (with no icing
or condensation)
Storage: 25 to 65°C (with no icing or
condensation)
Ambient humidity Operating: 35% to 85% (with no icing
or condensation)
Insulation
resistance
100 M min. (at 500 VDC) between each terminal and
mounting panel
Dielectric
strength
1,000 VAC, 50/60 Hz for 1 min between each terminal
and mounting panel
Noise
immunity
(See note.)
Power terminal: ±500 V (normal mode)
±1,500 V (common mode)
I/O cable: ±800 V (when the specified cable is
used)
Vibration
resistance
Destruction: 10 to 55 Hz, 1.5-mm double amplitude
10 sweeps of 5 min each in X, Y, and Z directions
Shock
resistance
Malfunction: 300 m/s2
3 times each in 6 directions on X, Y, and Z axes
Degree of
protection
IEC IP40 (front panel only)
M7F
5
Operation
Input Codes
Numeric Display
Positive Logic Static Input (M7F-@P@@@)
Negative Logic Static Input (M7F-@N@@@)
Input signal Display condition
103 digit 102 digit 101 digit 100 digit
Terminal no. RQPONMLKHGFEDCBA
Terminal
symbol
D4 C4 B4 A4 D3 C3 B3 A3 D2 C2 B2 A2 D1 C1 B1 A1 103
digit
102
digit
101
digit
100
digit
Input signals LLLLLLLLLLLLLLLL0000
LLLHLLLHLLLHLLLH1111
LLHLLLHLLLHLLLHL2222
L LHHL LHH L LHHL LHH3333
LHLLLHLLLHLLLHLL4444
LHLHLHLHLHLHLHLH5555
LHHLLHHLLHHLLHHL6666
LHHHLHHH LHHHLHHH7777
HLLLHLLLHLLLHLLL8888
HLLHHLLHHLLHHLLH9999
HLHLHLHLHLHLHLHLaaaa
HLHHHLHHHLHHHLHHbbbb
HHL LHHL L HHL LHHL L cccc
HHLHHHLHHHLHHHLHdddd
HHHLHHHL HHHLHHHL eeee
HHHHHHHHHHHHHHHHffff
Input signal Display condition
103 digit 102 digit 101 digit 100 digit
Terminal no. RQPONMLKHGFEDCBA
Terminal
symbol
D4 C4 B4 A4 D3 C3 B3 A3 D2 C2 B2 A2 D1 C1 B1 A1 103
digit
102
digit
101
digit
100
digit
Input signals HHHHHHHHHHHHHHHH0000
HHHLHHHL HHHLHHHL 1111
HHLHHHLHHHLHHHLH2222
HHL LHHL L HHL LHHL L 3333
HLHHHLHHHLHHHLHH4444
HLHLHLHLHLHLHLHL5555
HLLHHLLHHLLHHLLH6666
HLLLHLLLHLLLHLLL7777
LHHHLHHH LHHHLHHH8888
LHHLLHHLLHHLLHHL9999
LHLHLHLHLHLHLHLHaaaa
LHLLLHLLLHLLLHLLbbbb
L LHHL LHH L LHHL LHHcccc
LLHLLLHLLLHLLLHLdddd
LLLHLLLHLLLHLLLHeeee
LLLLLLLLLLLLLLLLffff
M7F
6
Dynamic Input (M7F-@D@@@)
Unit Display
The displays are lit when voltage is supplied to the power supply
terminals (positive and negative terminals).
Minus Symbol and Decimal Point
The DIP switch is used for minus symbol and decimal point settings
as shown in the following table.
Note: 1. The minus symbol and decimal point are always lit when the
corresponding pins of the DIP switch are set to ON.
2. “NC” means “not connected”.
Zero Suppression Function
The Unit has a function for blanking (i.e., turning OFF the display) to
not display 0 when the leftmost digits are zero. When DP (decimal
point) has been displayed using the DIP switch, the digits to the left
of the decimal point display digit will be blank as shown in the
following figure.
Note: The zero suppression function is normally operating.
Input signal Display condition
Terminal no. DCBAKLMNO
Terminal
symbol
D C B A S0S1S2S3S410
4
digit
103
digit
102
digit
101
digit
100
digit
Input signals LLLLLHHHH * * * * 0
* The data of S0 to S4 when S0 to S4
are high before S0 to S4 become
low will be held and displayed. Refer
to Operation Timing (Input Signal
Timing) on page 12 and Operation
Chart on page 12 for details.
LLLHHLHHH* * *1*
LLHLHHLHH* *2**
L LHHHHHLH * 3***
LHL LHHHHL 4****
LHLH LHHHH * * * * 5
LHHLHLHHH* * * 6*
LHHHHHLHH* * 7**
HLLLHHHLH*8***
HL LHHHHHL 9****
HLHL LHHHH * * * * a
HLHHHLHHH* * * b*
HHL LHHLHH * * c**
HHLHHHHLH * d***
HHHLHHHHL e****
HHHHLHHHH * * * * f
Display
contents
Model DIP switch function
Three digits
Numerals
and minus
symbol
M7F-3@@@F
Three digits
Numerals
and unit
M7F-3@@@T
Four digits
Numerals
only
M7F-4@@@
Four digits
Numerals
and minus
symbol
M7F-4@@@F
Four digits
Numerals
and unit
M7F-4@@@T
Five digits
Numerals
only
M7F-5@@@
No decimal point is designated.
The second, third, and fourth digits
are blank.
There is a decimal point between
the first and second digits.
The third and fourth digits are
blank.
There is a decimal point between
the third and second digits.
The fourth digit is blank.
There is a decimal point between
the fourth and third digits.
All digits are displayed.
Fourth
digit
DP
DP
DP
Third
digit
Second
digit
First
digit
M7F
7
Terminal Arrangement/Functions
Terminal Arrangement
Terminal Functions
DIP Switch Function
The DIP switch is used for symbol and decimal point settings. Refer to Terminal Arrangement, above, for details.
Signal inputPower supply
Signal input
Power supply
Power supply 0 V
Power supply (+)
Case
mark
Power supply 0 V
Power supply (+)
Data 20 × 102
Data 21 × 102
Data 22 × 102
Data 23 × 102
Data 20 × 103
Data 21 × 103
Data 22 × 103
Data 23 × 103
Data 20 × 100
Data 21 × 100
Data 22 × 100
Data 23 × 100
Data 20 × 101
Data 21 × 101
Data 22 × 101
Data 23 × 101
Signal inputPower supply
Power supply 0 V
Power supply (+)
Power supply 0 V
Power supply (+)
Power supply
Polarity guide
Terminal name
Terminal guide
Strobe 100
Strobe 101
Strobe 102
Strobe 103
Strobe 104
Data 20
Data 21
Data 22
Data 23
Signal input
Triangular
mark on
socket *
Triangular
mark on
socket *
Case
mark
XG4A Connector
Static Input Model Dynamic Input Model
Note: 1. Circled numbers are for the user's convenience. When preparing a socket, pay attention
when wiring the terminals to the direction of the polarity guide.
2.
The triangular mark ( ) on the M7F case indicates the start of the M7F terminal numbers. It
does not line up with the triangular mark ( ) on the connector. Incorrect wiring may cause a
short-circuit in the sequence output section, which could damage it.
*This is the location of the triangular mark on the XG4M-2030 Socket that is attached to the
Cable.
DIP Switch
Power supply ()
Power supply (+)
XG4A Connector
Input method Terminal
symbol
Name Function
Static input A1
B1
C1
D1
First digit (100)
data input
A1 (20)
B1 (21)
C1 (22)
D1 (23)
The numeral or symbol corresponding to the binary code signal will be
displayed as the first digit (100).
A2
B2
C2
D2
Second digit (101)
data input
A2 (20)
B2 (21)
C2 (22)
D2 (23)
The numeral or symbol corresponding to the binary code signal will be
displayed as the second digit (101).
A3
B3
C3
D3
Third digit (102)
data input
A3 (20)
B3 (21)
C3 (22)
D3 (23)
The numeral or symbol corresponding to the binary code signal will be
displayed as the third digit (102).
A4
B4
C4
D4
Fourth digit (103)
data input
A4 (20)
B4 (21)
C4 (22)
D4 (23)
The numeral or symbol corresponding to the binary code signal will be
displayed as the fourth digit (103).
+VPower supply Power supply and output terminal
0 VPower supply Power supply 0-V output terminal (GND)
Dynamic input A
B
C
D
Data input A (20)
B (21)
C (22)
D (23)
Displays the numeral or symbol corresponding to the binary code signal.
S0
S1
S2
S3
S4
Control input S0 (100)
S1 (101)
S2 (102)
S3 (103)
S4 (104)
Designates the digit to be displayed. Each digit will maintain the previous
value when this signal is input.
+VPower supply Power supply and output terminal
0 VPower supply Power supply 0-V output terminal (GND)
M7F
8
Block Diagram
Note: Circled numbers are the connector pin numbers.
Static Input Method Dynamic Input Method
Signal
Input
Circuit
Positive Logic Input Method Signal
Input
Circuit
Data signal input
Negative Logic Input Method Strobe signal input
External
power
supply input
Power supply
output into
the PLC
Signal
input
A1 to D1 to
A2 to D2 to
A3 to D3 to
A4 to D4 to
Switching
regulator
Input circuit
Driver circuit/
decoder circuit
LED display elements
Signal input
ON voltage : 9.6 V to power
supply voltage
OFF voltage : 3 VDC max.
Input impedance : Approx. 70 kǡ
Signal input
Short-circuit (ON) impedance
: 1 kǡ max.
Short-circuit (ON) residual voltage
: 3 VDC max.
Current flow for 0-ǡ short-circuit
: Approx. 0.2 mA
Open (OFF) impedance
: 100 kǡ min.
Signal input
Short-circuit (ON) impedance
: 1 kǡ max.
Short-circuit (ON) residual voltage
: 3 VDC max.
Current flow for 0-ǡ short-circuit
: Approx. 0.2 mA
Open (OFF) impedance
: 100 kǡ min.
Signal input
Short-circuit (ON) impedance
: 1 kǡ max.
Short-circuit (ON) residual voltage
: 3 VDC max.
Current flow for 0-ǡ short-circuit
: Approx. 0.2 mA
Open (OFF) impedance
: 100 kǡ min.
M7F
9
External Connections
Refer to Block Diagram on page 8 and Terminal Arrangement on
page 7 for external connections for the M7F according to the signal
input method.
PLC Connections
Refer to your PLC operation manual before connecting the PLC.
The M7F connects to the PLC without using any external resistor.
It is necessary to select the correct input method of the M7F
according to the output method of the PLC Output Unit. Refer to
Connectable PLCs on page 2 for details on the selection of the
correct input method.
A PLC Dynamic Output Unit can be used to save wiring. Use a
dynamic input model (M7F-@D@@@).
PLC
Terminal
name
Te r m i -
nal No.
PLC Output
Unit
DC power
supply (+)
12 to 24 VDC
(0 V)
Power
supply
input
Power
supply
input
PLC
A to D
0 V 0 V
With PLC Static Output Unit
1. M7F-@P@@@ Static Positive Logic Input Model
Connected to C500-OD212 Output Unit
Note: 1. Use the M7F positive logic input model if the PLC Output Unit has PNP output.
2. The PLC connects to the M7F with ease via the enclosed G79-Y@C Cable (with
connectors, sold separately).
Circuit Configuration
M7F
10
PLC
Terminal
name
Te r m i -
nal No.
PLC Output
Unit DC power
supply (+)
12 to 24 VDC
(0 V)
Power
supply
input
Power
supply
input
PLC
A to D
PLC
Terminal
name
Te r m i -
nal No.
PLC Output
Unit
DC power
supply (+)
12 to 24 VDC
(0 V)
Power
supply
input
Power
supply
input
PLC
A to D
Fuse
2. M7F-@N@@@ Static Negative Logic Input Model
1. Connected to C500-OD213 Output Unit
Circuit Configuration
Note: The PLC connects to the M7F with ease via the G79-O@C-@ Cable (with connectors, sold separately).
(The above example indicates 1 to 1 connection.)
2. Connected to C200H-OD215 Output Unit
Circuit Configuration
Note: 1. If the C200H-OD215 is used as a Static Output Unit, the switches on the rear panel of the PLC must be set as described in
the following table.
2. A G79-@C Connecting Cable (with connectors, sold separately) can be used to easily connect the PLC to the M7F.
SW1 (static output mode) OFF
SW2 OFF
SW3 OFF
SW4 OFF
SW5 (negative logic output) OFF
SW6 OFF Refer to your PLC operation manual for details.
M7F
11
PLC
Terminal
name
Te r m i -
nal No.
PLC Output
Unit
DC power
supply (+)
12 to 24 VDC
(0 V)
Power
supply
input
Power
supply
input
1. Status before PLC Program Runs (Data Storage Status)
Note: Word numbers and data are examples.
2. Example of PLC Program Operation
(Refer to your PLC operation manual for details.)
3. Status after PLC Program Has Run (Data Storage Status)
Note: Word numbers and data are examples.
Relay no. 15 14 13 12 11 10 09 08 07 06 05 04 03 02 01 00
Data no. 7654321076543210
Word
no.
005 4321
006 5
007
008
Relay no. 15 14 13 12 11 10 09 08 07 06 05 04 03 02 01 00
Data no. 7654321076543210
Word
no.
100 21
101 43
102 5
103
Note: 1. If the C200H-OD215 is used as a Dynamic Output Unit, the switches on the rear panel of the PLC must be set as described
in the following table.
2. A G79-@C Connecting Cable (with connectors, sold separately) can be used to easily connect the PLC to the M7F.
3. An eight-bit data signal is allocated to each strobe signal of the C200H-OD215 Dynamic Output Unit. On the other hand, each
strobe signal is input only to the rightmost four bits of the M7F. Thus the following program must run.
SW1 (dynamic output mode) ON
SW2 OFF
SW3 OFF
SW4 OFF
SW5 (positive logic output) ON
SW6 OFF
PLC
A to D
S0 to S4
Fuse
Circuit Configuration
With PLC Dynamic Output Unit
M7F-@D@@@ Dynamic Input Model
Connected to C200H-OD215 Output Unit
M7F 's display
Transfers the first digit's data of word 005 to the
first digit of word 100.
Transfers the second digit's data of word 005 to
the third digit of word 100.
Transfers the third digit's data of word 005 to
the first digit of word 101.
Transfers the fourth digit's data of word 005 to
the third digit of word 101.
Transfers the first digit data of word 006 to the
first digit of word 102.
M7F 's display
Refer to your PLC operation manual for details.
M7F
12
Operation
Operation Timing (Input Signal Timing)
Dynamic Input Method (M7F-@D@@@)
Operation Chart
Dynamic Input Method (M7F-@D@@@)
The following example shows the relationship between each input terminal and the display condition. (Example: 5-digit)
ts
tw
th
Data latch
Data input
signals A to D
Strobe input
(S0 to S4) Data latchData read
H
L
Pulse duration (tw) 1.5 ms
Hold time (th) 0.75 ms
Setup time (ts) 2.25 ms
Display
condition
H
L
H
L
H
L
H
L
H
L
Data contents 5 3 1 8 9
A numeric value is
displayed one digit at a
time via data signals A
to D.
Data input
signals
(A to D)
Strobe input signals
1st digit
(S0)
2
nd
digit
(S1)
3rd digit
(S2)
4th digit
(S3)
5th digit
(S4)
1st-digit display change 2nd-digit display change 3rd-digit display change 4th-digit display change 5th-digit display change
Data read
Data latch Data latch
Data read
Data latch Data latch
Data read
Data latch Data latch
Data read
Data latch Data latch
Data read
Data latch
Data input signals
Strobe input signals
M7F
13
Dimensions
Note: All units are in millimeters unless otherwise indicated.
14.2
10°
7.8
67.5
50
30.4
(13.5)4
31
67 +0.6
0.4
72
68
66
66.5
36 29 14.22
31
7 min.
+0.6
0.4
(72n5)+0.6
0.4
M7F-@@1@@
The M7F-4@1@ is
illustrated.
LED
M7F-4@1@F
M7F-4@1@T
M7F-5D1@
Panel Cutout
(Single Mounting)
(Side-by-side Mounting)
M7F-3@1@F
M7F-3@1@T
M7F-4@1@Panel thickness: 1 to 6 mm
n: Number of Units mounted
M7F
14
Safety Precautions
!CAUTION
Precautions for Safe Use
Do not use or store the product in the following locations.
Locations subject to direct radiant heat from heating equipment
Locations where the product may come into contact with water,
oil, or salt water
Locations subject to direct sunlight
Locations where dust or corrosive gases (in particular, sulfuric
or ammonia gas) are present
Locations subject to extreme temperature changes
Locations where icing or condensation may occur
Locations subject to excessive shocks or vibration
Locations subject to temperatures or humidity outside the
specified range
Locations outdoors or exposed to wind or rain
Locations subject to static electricity or noise
Do not use the product in locations subject to temperatures outside
the specified ranges or in locations subject to condensation. If the
product is installed in a panel, be sure that the temperature around
the product (not the temperature around the panel) does not go
outside the specified range. The life of components is dependent
on the temperature. The life of components shortens when the
temperature rises, and it lengthens when the temperature falls. The
life of components can be lengthened by lowering the temperature
inside the product.
Do not install the product near devices generating strong high
frequency waves or surges. When using a noise filter, check the
voltage and current and install it as close to the product as
possible.
Do not touch terminals or perform wiring while power is supplied to
the product. Doing so may result in injury or malfunction.
Do not touch the terminals while power is being supplied. Doing so
may result in product failure or malfunction.
When tightening the terminals or connecting connectors, support
the product with one hand to prevent it from being pushed out of the
front of the panel.
Wire to the correct terminal number. Incorrect wiring may result in
damage to or burning of components.
Be sure power supplies and power lines for control power supply
and inputs have appropriate specifications. Not using power
supplies and power lines with appropriate specifications may result
in malfunction, burning, or electric shock.
Do not attempt to disassemble, repair, or modify the product. Doing
so may occasionally result in minor or moderate injury.
Do not allow pieces of metal, wire clippings, or fine metallic
shavings or filings to enter the product. Doing so may occasionally
result in fire or product failure.
For DC input, use an SELV power supply with overcurrent
protection. Specifically, use an SELV power supply with double or
reinforced insulation between input and output, and an output
voltage of 30 Vrms with 42.2 V peak or 60 VDC maximum.
Recommended power supply: S8VS-06024@ (OMRON product)
Precaution for Correct Use
Wiring
Do not tighten the power supply terminals with excessive force
when wiring. Doing so may damage the terminals. Tighten each of
them to a torque of 0.29 to 0.49 N·m.
Do not impose excessive force on the rear panel when tightening
the terminals of the M7F or connecting a connector to the M7F.
When tightening the terminals of the M7F or connecting a
connector to the M7F, hold the displays by hand, otherwise the
displays may protrude from the case.
Environment
When using the M7F in places with dust, metal powder, or sprayed
oil, be sure to take appropriate measures so that no dust, metal
powder, or sprayed oil will penetrate the interior of the Display Units.
Mounting
When panel-mounting, make sure that the side of the case marked
“TOP” is upward.
When panel-mounting, do not press the central part of the displays,
otherwise the displays may be damaged. Press the flange part.
Connections
If power will be supplied to the M7F from the PLC's I/O service
power supply, make sure that the current consumption of the M7F
does not exceed the rated capacity of the service power supply.
It is recommended to supply power to the M7F from a dedicated
DC power supply in order to protect the PLC from being damaged.
When using a controller other than the PLC or another company's
PLC, be sure to check the terminal arrangement of the connector of
the controller or the PLC. The terminal arrangement of OMRON's
cables incorporating connectors corresponds to that of the PLC.
Removing Color Plate
There is a gap (with a width of approximately 1 mm) between the
case and color plate on the left and right sides. To remove the color
plate, insert a flat-blade screwdriver into either one of the gaps and
move the color plate upwards.
Replacing Unit Plate
Remove the unit plate with a pair of tweezers.
Before pasting a unit plate to the plate holder, remove the ground
paper from the unit plate. Paste the unit plate to the plate holder so
that the symbol mark or character(s) of the face plate will be on the
bottom side (i.e., the decimal-point side) of the M7F.
Tighten the screws on the terminal block securely using
the recommended tightening torque of 0.29 to 0.49 N·m.
Loose screws may occasionally cause fire, resulting in
minor or moderate injury, or damage to the equipment.
Case
Color plate
TOP display panelUnit plate
Plate holder
M7F
15
Attaching Color Plate
Insert the projecting parts of the color plate into the square holes of
the case to attach the color plate to the case.
DIP Switch Settings
The DIP switch can be set with the tip of a ball-point pen or small
screwdriver. Do not use anything that has a sharp edge (e.g.,
tweezers) to set the DIP switch.
Color plate projecting part (There are
four color plate projecting parts.)
Square hole (There are four square
holes.)
In the interest of product improvement, specifications are subject to change without notice.
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.
Terms and Conditions Agreement
Read and understand this catalog.
Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you
have any questions or comments.
Warranties.
(a) Exclusive Warranty. Omron’s exclusive warranty is that the Products will be free from defects in materials and workmanship
for a period of twelve months from the date of sale by Omron (or such other period expressed in writing by Omron). Omron
disclaims all other warranties, express or implied.
(b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUT
NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS. BUYER
ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE
PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE.
Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the
Products or otherwise of any intellectual property right. (c) Buyer Remedy. Omron’s sole obligation hereunder shall be, at
Omron’s election, to (i) replace (in the form originally shipped with Buyer responsible for labor charges for removal or
replacement thereof) the non-complying Product, (ii) repair the non-complying Product, or (iii) repay or credit Buyer an amount
equal to the purchase price of the non-complying Product; provided that in no event shall Omron be responsible for warranty,
repair, indemnity or any other claims or expenses regarding the Products unless Omrons analysis confirms that the Products
were properly handled, stored, installed and maintained and not subject to contamination, abuse, misuse or inappropriate
modification. Return of any Products by Buyer must be approved in writing by Omron before shipment. Omron Companies shall
not be liable for the suitability or unsuitability or the results from the use of Products in combination with any electrical or
electronic components, circuits, system assemblies or any other materials or substances or environments. Any advice,
recommendations or information given orally or in writing, are not to be construed as an amendment or addition to the above
warranty.
See http://www.omron.com/global/ or contact your Omron representative for published information.
Limitation on Liability; Etc.
OMRON COMPANIES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES,
LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS,
WHETHER SUCH CLAIM IS BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY.
Further, in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted.
Suitability of Use.
Omron Companies shall not be responsible for conformity with any standards, codes or regulations which apply to the
combination of the Product in the Buyer’s application or use of the Product. At Buyer’s request, Omron will provide applicable
third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself
is not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine,
system, or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product
with respect to Buyer’s application, product or system. Buyer shall take application responsibility in all cases.
NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE
QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS,
AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE
OVERALL EQUIPMENT OR SYSTEM.
Programmable Products.
Omron Companies shall not be responsible for the user’s programming of a programmable Product, or any consequence
thereof.
Performance Data.
Data presented in Omron Company websites, catalogs and other materials is provided as a guide for the user in determining
suitability and does not constitute a warranty. It may represent the result of Omron’s test conditions, and the user must correlate
it to actual application requirements. Actual performance is subject to the Omron’s Warranty and Limitations of Liability.
Change in Specifications.
Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our
practice to change part numbers when published ratings or features are changed, or when significant construction changes are
made. However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers
may be assigned to fix or establish key specifications for your application. Please consult with your Omron’s representative at
any time to confirm actual specifications of purchased Product.
Errors and Omissions.
Information presented by Omron Companies has been checked and is believed to be accurate; however, no responsibility is
assumed for clerical, typographical or proofreading errors or omissions.
2013.7
In the interest of product improvement, specifications are subject to change without notice.
OMRON Corporation
Industrial Automation Company
http://www.ia.omron.com/
(c)Copyright OMRON Corporation 2013 All Right Reserved.
Mouser Electronics
Authorized Distributor
Click to View Pricing, Inventory, Delivery & Lifecycle Information:
Omron:
M7F-4N1G M7F-4N1R M7F-4P1R M7F-5D1R M7F-4D1G M7F-4P1G M7F-3N1GT M7F-3N1RT M7F-4D1R
M7F-3P1RT M7F-4D1RT