Model 4020 & 4030 Accelerometer
Model 4020 & 4030 Rev B www.meas-spec.com 08/25/2014
32 Journey Ste. 150 Aliso Viejo, CA 92656 949-716-5377 t&m@meas-spec.com
DC Response, Silicon MEMS
Dual & Triaxial Output Options
Low Cost, Great Value
±2g & ±6g Measurement Range
Rugged Construction
dimensions
FEATURES
5-30Vdc Excitation Voltage
Environmentally Sealed
Low Pass Filtered Output
Capacitive Silicon MEMS Element
Integral #24 AWG Cable
Self-Test Enabled
The Model 4020 & 4030 are low noise,
signal conditioned DC accelerometers
packaged in a durable molded housing.
The accelerometers are offered in ±2g &
±6g ranges with a nominal 0-200Hz
bandwidth. The model 4020 is a dual axis
configuration (X&Y axes) while model 4030
is a triaxial configuration.
The capacitive silicon MEMS sensing
element offers high resolution and long
term stability for critical measurement
applications.
APPLICATIONS
Low Frequency Vibration Monitoring
Tilt & Inclination Measurement
Motion Measurements
Structural Monitoring
Model 4020 & 4030 Accelerometer
Model 4020 & 4030 Rev B www.meas-spec.com 08/25/2014
32 Journey Ste. 150 Aliso Viejo, CA 92656 949-716-5377 t&m@meas-spec.com
performance specifications
ordering info
PART NUMBERING Model Number+Range+Cable Length
40XX-GGG-CCC
l l l____Cable Length (120 is 120 inches)
l l________Range (002 is ±2g)
l___________Dual or Triaxial Configuration (4020; Dual Axis, 4030; Triaxial)
Example: 4030-002-120
Model 4030 (triaxial), ±2g range, 120 inch cable length
The information in this sheet has been carefully reviewed and is believed to be accurate; however, no responsibility is assumed for inaccuracies. Furthermore, this information
does not convey to the purchaser of such devices any license under the patent rights to the manufacturer. Measurement Specialties, Inc. reserves the right to make changes
without further notice to any product herein. Measurement Specialties, Inc. makes no warranty, representation or guarantee regarding the suitability of its product for any
particular purpose, nor does Measurement Specialties, Inc. assume any liability arising out of the application or use of any product or circuit and specifically disclaims any and all
liability, including without limitation consequential or incidental damages. Typical parameters can and do vary in different applications. All operating parameters must be validated
for each customer application by customer’s technical experts. Measurement Specialties, Inc. does not convey any license under its patent rights nor the rights of others.
Parameters
DYNAMIC
Notes
Range (g)
±2
±6
Sensitivity (mV/g)
1000
333
±10%
Frequency Response (Hz)
0-200
0-200
±5%
Non-Linearity (%FSO)
±1
±1
Transverse Sensitivity (%)
<3
<3
Shock Limit (g)
2000
2000
Residual Noise (µV RMS)
600
240
Passband
Residual Noise (µg/√Hz RMS)
50
42
Self Test Output Change (mV)
X = +210 ±90
X = +70 ±30
Ground ST Lead
Y = -210 ±90
Y = -70 ±30
Z = -340 ±190
Z = -110 ±65
ELECTRICAL
Zero Acceleration Output (V)
2.5 ±0.1
Excitation Voltage (Vdc)
5 to 30
Excitation Current (mA)
4
Full Scale Output Voltage (Vdc)
±2
Ground Isolation
Isolated from Mounting Surface
ENVIRONMENTAL
Thermal Zero Shift (%FSO)
±4
-40° to +85°C
Thermal Sensitivity Shift (%)
±5
-40° to +85°C
Operating Temperature (°C)
-40 to 85
Humidity
Epoxy Sealed, IP65
PHYSICAL
Housing Material
Nylon 6-6, 30% GF, Brass Inserts at Mounting Holes
Weight (grams)
50
Mounting
2x ¼ or M6 Screws
Mounting Torque
18 lb-in (2.0 N-m)
Optional accessories: 121 3-Channel Precision Low Noise DC Amplifier