Embedded Power for Business-Critical Continuity Rev. 06.30.09_69 NFS110 Series of 5 NFS110 Series Single & quad output Total Power: 80 - 110 W Input Voltage: 85 - 264 Vac 120 - 370 Vdc # of Outputs: Single, quad Special Features * 7.0 x 4.25 x 1.8 inch package * Overvoltage and short circuit protection * 110 W with 20 CFM * Adjustable outputs * EN55022, EN55011 conducted emissions level B * UL, VDE and CSA safety approvals * CE mark * Available RoHS compliant * 2 year warranty Safety * VDE0805/EN60950/ * IEC950/IEC1010 File No. 10401-3336-0213 * Licence No. 4001467 7 * UL1950 File No. E132002 * CSA C22.2 No. 950 File No. LR41062C Electrical Specifications Output Voltage adjustability: +5.1 V o/p on multi's 5.1 V single output 12 V single output 15 V single output 24 V single output 3.0% 3.0% 12 - 14 V 15 - 18 V 24 - 30 V Line regulation: 0.1% max. Overshoot/undershoot: LL to HL, FL All outputs on all units At turn-on Temperature coefficient: All outputs 0.02%/C Overvoltage protection: Multi o/p 5.1 V only 5.1 V single output 12 V single output 15 V single output 24 V single output 6.25 V 0.75 V 6.25 V 0.75 V 15.75 V 1.0 V 22 V 1.5 V 33 V 2.5 V Output power limit: Primary power limited Minimum output current: (See Note 13) Pin max. 160 W Pout min. 110 W 0A Short circuit protection: Burst mode operation 0% Input Input voltage range: 85 - 264 Vac 120 - 370 Vdc Input frequency range: 47 - 440 Hz Input surge current: 230 Vac 35 A Safety ground leakage current: 110 Vac, 50 Hz 230 Vac, 50 Hz 0.2 mA, max. 0.4 mA, max. All specifications are typical at nominal input, full load at 25 C unless otherwise stated Embedded Power for Business-Critical Continuity Rev. 06.30.09_69 NFS110 Series of 5 EMC Characteristics Conducted emissions: Radiated emissions: ESD air: EN55022, FCC part 15 EN55022, FCC part 15 EN61000-4-2, level 3 Level B Level A Perf. criteria 1 ESD contact: EN61000-4-2, level 4 Perf. criteria 1 Surge: EN61000-4-3, level 3 Perf. criteria 1 Fast transients: EN61000-4-4, level 3 Perf. criteria 1 Radiated immunity: EN61000-4-5, level 3 Perf. criteria 2 Conducted immunity: EN61000-4-6, level 3 Perf. criteria 1 Hold-up time: 110 Vac @ 80 W 110 Vac @ 110 W 230 Vac @ 80 W 230 Vac @ 100 W 35 ms 17 ms 140 ms 100 ms Efficiency: Multiple outputs +5.1 V single 12 V and 15 V singles 24 V single 70% typical 70% typical 72% typical 75% typical Isolation voltage: Input/output Input/chassis 3000 Vac 1500 Vac Approvals and standards: (see note 12) VDE0805, EN60950, IEC950, IEC1010, UL1950, CSA C22.2 No. 950 Weight: Singles Multiple outputs 550 g (19.4 oz) 600 g (21.2 oz) MTBF (@25 C): MIL-HDBK-217E 125,000 hours min. General Specifications Environmental Specifications Thermal performance: Operating ambient 0 C to +70 C (See notes 9, 10) Non-operating -40 C to +85 C 0 C to 50 C convection cooled 80 W +50 C to +70 C, convection cooled Derate 2 W/C 0 C to +50 C, 20 CFM forced air 110 W +50 C to +70 C, 20CFM forced air Derate 2.75 W/C Peak, 0 C to +50 C, max. 60 seconds 110W Relative humidity: Non-condensing 5 to 95% RH Altitude: Operating 10,000 feet max. Non-operating 40,000 feet max. 5 - 500 Hz 2.4 G rms peak Vibration: (See Note 11) Embedded Power for Business-Critical Continuity Rev. 06.30.09_69 NFS110 Series of 5 Ordering Information Max (1) Peak (2) Fan (3) +5.1 V 8A 20 A 10 A 50 mV 2.0% 5 6 7 8 9 10 11 12 13 14 15 Total Regulation (5) +12 V 4.5 A 9A 5A 120 mV 3.0% 0.5 A 1.5 A 1A 120 mV 3.0% -5 V 0.5 A 1.5 A 1A 50 mV 3.0% +5.1 V (IA) 8A 20 A 10 A 50 mV 2.0% 3.5 A 4.5 A 4.5 A 240 mV +10/-5.0% +12 V 4.5 A 9A 5A 120 mV 3.0% (6) M odel Numbers (13, 14, F) NFS110-7601PJ NFS110-7602PJ (6) -12 V 0.5 A 1.5 A 1A 120 mV 3.0% +5.1 V 8A 20 A 10 A 50 mV 2.0% 15 V 4A 7.5 A 5A 150 mV 4.0% -15 V 0.5 A 1.5 A 1A 150 mV 3.0% -5 V 0.5 A 1.5 A 1A 50 mV 3.0% 12 V 7A 9A 9A 120 mV 2.0% NFS110-7612J (7,8) 15 V 5A 7.3 A 7.3 A 150 mV 2.0% NFS110-7615J (7,8) 24 V 3.5 A 4.5 A 4.5 A 240 mV 2.0% NFS110-7624J (7,8) Notes 3 4 Ripple (4) -12 V +24 V (IB) 1 2 Output Currents Output Voltage Convection cooled, 80 W maximum. Peak outputs lasting less than 60 seconds with duty cycle less than 10%. Total peak power must not exceed 110 W. Forced air, 20 CFM at 1 atmosphere, 110 W maximum. Figure is peak-to-peak. Output ripple is measured across a 50 MHz bandwidth using a 12 inch twisted pair terminated with a 47 F capacitor. Total regulation is defined as the static output regulation at 25 C, including initial tolerance, line voltage within stated limits and output voltages adjusted to their factory settings. To achieve stated regulation on the 24 V output on the NFS110-7602PJ, the following load condition must be true: IA / IB 5, where: IA = +5.1 V output current, and IB = +24 V output current The +24 V output will maintain 5.0% regulation under the following additional condition: IA 5 A. Single output models have floating outputs which may be referenced as either positive or negative. Higher voltage supplies may be adjusted over a wide output voltage range, as long as the total output power does not exceed 80 Watts (natural convection) or 110 Watts (forced air). Power fail detect not available on single output models. Derating curve is application specific for ambient temperatures >50 C, for optimum reliability no part of the heatsink should exceed 90 C and no semiconductor case temperature should exceed 100 C. Caution: Allow a minimum of 1 second after disconnecting the power when making thermal measurements. Three orthogonal axes, random vibration, 10 minute test for each axis. This product is only for inclusion by professional installers within other equipment and must not be operated as a stand alone product. Artesyn Technologies recommends a minimum load of 11 W to achieve the design MTBF. See the derating curve on page 3. The `J' suffix indicates that these parts are Pb-free (RoHS 6/6) compliant. NOTICE: Some models do not support all options. Please contact your local Emerson Network Power representative or use the on-line model number search tool at http://www.PowerConversion.com to find a suitable alternative. NFS110-7604PJ Transient Response NFS110-7601PJ +5.1 V (7.5 A to 10 A) +12 V (2.5 A to 5 A) -12 V (0.5 A to 1 A) -5 V (0.5 A to 1 A) 150 mV peak, 1 ms recovery 100 mV peak, 0.5 ms recovery 100 mV peak, 0.5 ms recovery 100 mV peak, 0.5 ms recovery NFS110-7602PJ +5.1 V (7.5 A to 10 A) +24 V (1.5 A to 3 A) +12 V (2.5 A to 5 A) -12 V (0.5 A to 1 A) 150 mV peak, 1 ms recovery 300 mV peak, 1 ms recovery 100 mV peak, 0.5 ms recovery 100 mV peak, 0.5 ms recovery NFS110-7604PJ +5.1 V (7.5 A to 10 A) +15 V (2.5 A to 5 A) -15 V (0.5 A to 1 A) -5 V (0.5 A to 1 A) 150 mV peak, 1 ms recovery 100 mV peak, 0.5 ms recovery 100 mV peak, 0.5 ms recovery 100 mV peak, 0.5 ms recovery NFS110-7605J +5.1 V (10 A to 20 A) 250 mV peak, 1 ms recovery NFS110-7612J: +12 V (4.5 A to 9 A) 360 mV peak, 1 ms recovery NFS110-7615J +15 V (3.65 A to 7.3 A) 450 mV peak, 1 ms recovery NFS110-7624J +24 V (2.25 A to 4.5 A) 720 mV peak, 1 ms recovery Embedded Power for Business-Critical Continuity Rev. 06.30.09_69 NFS110 Series of 5 OPTIONAL POWER FAIL DETECT TIMING DIAGRAM AC (J1) mating connector Molex 09-50-3051 or Molex 09-91-0500 mating connector with 2478 or equivalent crimp terminals. Power fail detect signal (Note 8) AC INPUT 4.75V HIGH DC (J2) mating connector Molex 09-50-3131 or Molex 09-91-1300 mating connector with 2478 or equivalent crimp terminals. PFD SIGNAL 50ms T1 200ms T2 will vary with line and load T3 3ms Pout: 110W PFD output is an open collector which will sink 40mA in the low state. 4.75V 5V OUTPUT 3.5V MIN LOW 0-0.4 MAX T3 T1 T2 0.475 0.010 (12.07) DERATING CURVE (See Notes 9, 10) 1.80 (45.72) MAX 1.00 0.005 (25.4) Output Power (Watts) 110W 0.050 0.020 (1.27) 80W PIN 1 Voltage Adjust Optional Power Fail Detect Circuit (Key = Pin 2) 4.250 0.020 (107.95) 20 CFM FORCED AIR COOLING 6-32 UNC (4PL) 1.55 0.005 (39.37) 3.35 0.015 (85.09) NATURAL CONVECTION COOLING J2 Pin 1 PIN 1 L1 11W J1 C6 F1 11W MINIMUM LOAD REQUIRED AT 230VAC 0W 0.156 DIA. HOLE (4PL) 0C 10C 7.00 0.020 (177.8) ALL DIMENSIONS IN INCHES (mm) Mechanical Notes: A Metallic or non-metallic stand-offs (maximum diameter 5.4mm) can be used in all four mounting holes without effecting safety approval. B The ground pad of the mounting hole near J1, allows system grounding through a metal stand-off to the system chassis. C The heat sink is grounded, and allows system grounding by mechanical connection to the system chassis. D The supply must be mechanically supported using the PCB mounting holes and may be additionally supported by the heatsink mounting holes. E It is always advisable to attach the power supply heat sink to another thermal dissipator (such as a chassis or finned heatsink etc). The resulting decrease in heat sink mounted component temperatures will improve power supply lifetime. F A standard L-bracket and cover is available for mounting which contains all screws, connectors and necessary mounting hardware. The kit is available, order part number "NFS110CJ". 20C 30C 40C 50C 60C 70C Pin Connections 5A, 250 VAC 6.50 0.005 (165.1) 0.250 0.010 (6.35) 40W T1 T1 3.750 0.005 (95.25) 0.250 0.010 (6.35) 55W J1 -7601PJ -7602 P -7604PJ Singles Pin 1 AC Ground AC Ground AC Ground AC Ground Pin 2 AC Neutral AC Neutral AC Neutral AC Neutral Pin 3 AC Line AC Line AC Line AC Line Pin 1 +5.1 V +5.1 V +5.1 V Vout Pin 2 +5.1 V +5.1 V +5.1 V Vout J2 Pin 3 +5.1 V +5.1 V +5.1 V Pin 4 Return Return Return Vout Return Pin 5 Return Return Return Return Pin 6 Return Return Return Return Pin 7 Return Return Return Return Pin 8 +12 V +12 V +15 V Vout Pin 9 +12 V +12 V +15 V Vout Pin 10 PFD PFD PFD N/C Pin 11 -12 V -12 V -15 V N/C -5 V +24 V Pin 12 Pin 13 Removed for Key N/C = no connection -5 V N/C Embedded Power for Business-Critical Continuity Americas Rev. 06.30.09_69 NFS110 Series of 5 5810 Van Allen Way Carlsbad, CA 92008 USA Telephone: +1 760 930 4600 Facsimile: +1 760 930 0698 Europe (UK) Waterfront Business Park Merry Hill, Dudley West Midlands, DY5 1LX United Kingdom Telephone: +44 (0) 1384 842 211 Facsimile: +44 (0) 1384 843 355 Asia (HK) 14/F, Lu Plaza 2 Wing Yip Street Kwun Tong, Kowloon Hong Kong Telephone: +852 2176 3333 Facsimile: +852 2176 3888 For global contact, visit: www.PowerConversion.com techsupport.embeddedpower @emerson.com While every precaution has been taken to ensure accuracy and completeness in this literature, Emerson Network Power assumes no responsibility, and disclaims all liability for damages resulting from use of this information or for any errors or omissions. Emerson Network Power. The global leader in enabling business-critical continuity. AC Power Connectivity DC Power Embedded Computing Embedded Power Monitoring Outside Plant Power Switching & Controls Precision Cooling Racks & Integrated Cabinets Services Surge Protection EmersonNetworkPower.com Emerson Network Power and the Emerson Network Power logo are trademarks and service marks of Emerson Electric Co. (c)2009 Emerson Electric Co.