Specifications
JRATINGS/CHARACTERISTICS
Part number F3M-S625 F3M-S626 F3M-S825 F3M-S826 F3M-S1213 F3M-S1225
Sensing object 6-inch (5-inch) semiconductor
silicon wafers and transparent
wafers (with transparency of
92% max.) (See Note.)
8-inch semiconductor silicon
wafers and transparent wafers
(with transparency of 92% max.)
(See Note.)
12-inch semiconductor silicon
wafers and 12-inch SIC wafers
(with transparency of 30% max.)
Number of channels 25 26 25 26 13 25
Optical axis pitch 4.76 mm 6.35 mm 10 mm
Optical axis width 1.5 mm
Light source Infrared LED (940 nm)
Power supply voltage 12 to 24 VDC ±10%, ripple (p-p): 10% max.
Current consumption 120 mA max.
Output Control
output Load power supply voltage:30 VDC
Load current: 20 mA max. (residual voltage: 1 V max.)
Inflow current: 20 mA
Parallel output fromall channels, NPN open collector
Dark-ON operation
Answer-back
output When remote teaching is ON,pin 28 will be used forthis function.
Self-
diagnostic
output
Load power
supply voltage:
30 VDC max.
Load current:
20 mA max.
(Residual
voltage: 1 V
max.)
Inflow current:
20 mA
NPN open
collector
--- Load power
supply voltage:
30 VDC max.
Load current:
20 mA max.
(Residual
voltage: 1 V
max.)
Inflow current:
20 mA
NPN open
collector
--- Load power supply voltage:
30 VDC max.
Load current: 20 mA max.
(Residual voltage: 1 V max.)
Inflow current: 20 mA
NPN open collector
Indicators Power Green indicator is ON when power is being supplied.
Warning Red indicator is ON under the following conditions:
Teaching, no sensing object, insufficient light, or error.
Response time 10 ms max.
Control output interrupt input All outputs interrupted: GND and control output interrupt input terminals are short-circuited and 0-V
short-circuit current is 1 mA max.
Output interrupt reset: GND and control output interrupt input terminals are opened or the voltage is
between 9 V and the working power supply voltage.
Remote ON GND and remote input terminals are short-circuited and 0-V short-circuitcurrentis 1 mA max.
teaching
input OFF GND and remote inputterminals are opened orthe voltage is between 9 V and the working power
supply voltage.
Teaching check function Orange LED indicator
Ambient
temperature Operating 0°Cto40°C(32°F to 104°F)with no icing or condensation 0°Cto55°C(32°F to 131°F)
with no icing or condensation
Storage -- 2 5 °Cto60°C(--13°F to 140°F) -- 2 5 °Cto60°C(--13°F to 140°F)
Relative humidity 35% to 85%with no condensation
Ambient illumination Fluorescent lamp: 1,500 ℓxmax.
Noise resistance Power supply line: ±480 V in normal mode with noise simulator
Static electrical noise: No malfunction or destruction at ±8kV
Vibration resistance 10 to 55 Hz, 0.5-mm double amplitude for 2 hrs each in X, Y, and Z axes
Shock resistance 300 m/s2(30G) for 3 times each in X, Y, and Z axes
Degree ofprotection IEC60529 IP40
Connection Preleaded cable (standard cable length: 100 mm) Connector
(This table continues on the nextpage.)