114 Page 2 SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE ©2006 TELEDYNE RELAYS
www.teledynerelays.com 114/0706/Q1
PERFORMANCE CURVES
(NOTE 2)
SERIES 114
GENERAL ELECTRICAL SPECIFICATIONS (–65°C to +125°C unless otherwise noted) (Notes 2 & 3)
DETAILED ELECTRICAL SPECIFICATIONS (–65°C to +125°C unless otherwise noted) (Note 3)
Contact Arrangement 2 Form C (DPDT)
Rated Duty Continuous
Contact Resistance 0.1 ohm max. before life; 0.2 ohm max. after life at 1A/28Vdc (measured 1/8" from header)
Contact Load Ratings (DC)
(See Fig. 2 for other DC
resistive voltage/current ratings)
Resistive: 1 Amp/28Vdc
Inductive: 200 mA/28Vdc (320 mH)
Lamp: 100 mA/28Vdc
Low Level: 10 to 50 μA/10 to 50mV
Contact Load Ratings (AC) Resistive: 250 mA/115Vac, 60 and 400 Hz (Case not grounded)
100 mA/115Vac, 60 and 400 Hz (Case grounded)
Contact Life Ratings
10,000,000 cycles (typical) at low level
1,000,000 cycles (typical) at 0.5A/28Vdc resistive
100,000 cycles min. at all other loads specified above
Contact Overload Rating 2A/28Vdc Resistive (100 cycles min.)
Contact Carry Rating Contact factory
Operate Time 2.0 msec max. at nominal rated coil voltage
Release Time 114 Series: 1.5 msec max. 114D, 114DD Series: 4.0 msec max.
Contact Bounce 1.5 msec max.
Intercontact Capacitance 0.4 pf typical
Insulation Resistance 10,000 megohms min. between mutually isolated terminals
Dielectric Strength Atmospheric pressure: 500 Vrms/60Hz 70,000 ft.: 125 Vrms/60Hz
Negative Coil Transient (Vdc) 114D, 114DD 1.0 max
Diode P.I.V. (Vdc) 114D, 114DD 100 min.
BASE PART
NUMBERS
(See Note 8 for full P/N example)
114-5
114D-5
114DD-5
114-6
114D-6
114DD-6
114-9
114D-9
114DD-9
114-12
114D-12
114DD-12
114-18
114D-18
114DD-18
114-26
114D-26
114DD-26
Coil Voltage (Vdc) Nom. 5.0 6.0 9.0 12.0 18.0 26.5
Max. 5.8 8.0 12.0 16.0 24.0 32.0
Coil Resistance
(Ohms ±10% @25°C)
114, 114D 50 98 220 390 880 1560
114DD (Note 4) 39 78 220 390 880 1560
Coil Current (mAdc @25°C)
(114DD Series)
Min. 93.2 58.3 33.0 25.6 17.5 14.8
Max. 128.2 78.3 42.9 32.8 22.1 18.5
Pick-up Voltage (Vdc, Max.) 114, 114D 3.5 4.5 6.8 9.0 13.5 18.0
114DD 4.0 5.0 7.8 10.0 14.5 19.0
Drop-out Voltage (Vdc)
114, 114D Min. 0.14 0.18 0.35 0.41 0.59 0.89
Max. 2.3 3.2 4.9 6.5 10.0 13.0
114DD Min. 0.6 0.7 0.8 0.9 1.1 1.4
Max. 2.8 3.4 5.3 6.5 10.0 13.0
0
.1
.2
.3
.4
10
20
30
40
50
60
70
.01 0.5 .1 .5 1.0
FREQUENCY (GHz)
FIGURE 1
TYPICAL RF PERFORMANCE
INSERTION LOSS
RETURN LOSS (VSWR)
ISOLATION ACROSS CONTACTS
ISOLATION ACROSS POLES
1.92
1.22
1.07
1.02
1.01
1.00
1.00
VSWR
300
250
200
150
100
50
0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0
LOAD CURRENT (AMPS DC)
FIGURE 2
TYPICAL DC CONTACT RATING (RESISTIVE)
LOAD VOLTAGE (VDC)
dB