Technical Data 2041
Effective June 2017
Supersedes October 2011
Product features
IcULus: AGX 0-10A (Guide JDYX, File E 19180 and Guide
JDYX7, File E19180)
UL Recognized Card: AGX 15-30A (Guide JDYX2, File E19180)
CSA Component Acceptance Card : AGX 15-30A (Class No.
1422-01, File 53787)
AGX
1/4” x 1” Fast-acting glass tube fuses
Fast-acting glass tube fuse
1/4" x 1" (6.3 x 25.4mm) physical size
Glass tube, nickel-plated brass endcap construction
For instruments, electronic and small appliance circuits
UL Listed product meets standard 248-14
Agency information
Insert packaging code prefix before part number, e.g.,
BK/AGX-1
Ordering information
Electrical Characteristics
Rated Current % of Amp Rating Opening Time
1/10 - 30A 110% 4 hours. min.
135% 60 minutes max.
1/10 - 2A 200% 5 seconds max.
2.5 - 30A 200% 2 minutes max.
Specications
Part Number Voltage
Interrupting rating (amps)
Agency Approvals
(Amps) Rating Vac 250Vac 125Vac 32Vac Lower Upper cULus cURus
AGX-
1
/
10
250 35 10,000 - N/A N/A X -
AGX-
1
/
8
250 35 10,000 - 7.610 10.293 X -
AGX-
3
/
16
250 35 10,000 - 3.086 4.176 X -
AGX-
2
/
10
250 35 10,000 - 2.918 3.948 X -
AGX-
1
/
4
250 35 10,000 - 1.010 1.366 X -
AGX-
3
/
10
250 35 10,000 - 0.789 1.067 X -
AGX-
3
/
8
250 35 10,000 - 0.547 0.740 X -
AGX-
4
/
10
250 35 10,000 - 0.514 0.568 X -
AGX-
1
/
2
250 35 10,000 - 0.318 0.431 X -
AGX-
3
/
4
250 35 10,000 - 0.158 0.215 X -
AGX-1 250 35 10,000 - 0.111 0.150 X -
AGX-1-
1
/
4
250 100 10,000 - 0.080 0.109 X -
AGX-1-
1
/
2
250 100 10,000 - 0.064 0.086 X -
AGX-2 250 100 10,000 - 0.041 0.055 X -
AGX-2-
1
/
2
250 100 10,000 - 0.031 0.043 X -
AGX-3 250 100 10,000 - 0.027 0.036 X -
AGX-4 250 200 10,000 - 0.021 0.028 X -
AGX-5 250 200 10,000 - 0.014 0.019 X -
AGX-6 250 200 10,000 - 0.011 0.015 X -
AGX-7 250 200 10,000 - 0.009 0.015 X -
AGX-8 250 200 10,000 1000 0.008 0.011 X -
AGX-10 250 200 10,000 1000 0.006 0.008 X -
AGX-15** 250 200 200 1000 0.004 0.005 - X
AGX-20** 250 200 200 1000 0.003 0.003 - X
AGX-25*** 125 - 100 1000 0.002 0.003 - X
AGX-30*** 125 - 100 1000 0.002 0.002 - X
* Typical DC Cold Resistance (Measured at <10% of rated current).
** Component Recognized rating 125V & 250V.
*** Component Recognized rating 125V.
Typical DC Cold Resistance (Ω)*
Eaton
Electronics Division
1000 Eaton Boulevard
Cleveland, OH 44122
United States
www.eaton.com/electronics
© 2017 Eaton
All Rights Reserved
Printed in USA
Publication No. 2041 BU-SB11901
June 2017
Eaton is a registered trademark.
All other trademarks are property
of their respective owners.
Life Support Policy: Eaton does not authorize the use of any of its products for use in life support devices or systems without the express written
approval of an officer of the Company. Life support systems are devices which support or sustain life, and whose failure to perform, when properly
used in accordance with instructions for use provided in the labeling, can be reasonably expected to result in significant injury to the user.
Eaton reserves the right, without notice, to change design or construction of any products and to discontinue or limit distribution of any products. Eaton also
reserves the right to change or update, without notice, any technical information contained in this bulletin.
AGX
1/4” x 1” Fast-acting glass tube fuses
Technical Data 2041
Effective June 2017
25.4±0.8
1.000±0.31
6.35±0.1
0.250±0.004
Dimensions - mm (in)
TIME IN SECONDS
TIME IN SECONDS
1/4
1
2
5
Time-Current Curves
CURRENT IN AMPS
CURRENT IN AMPS
Packaging
Packaging Code Prefix Description
BK 100 fuses packed into a cardboard carton