1.27 mm pitch connector
For panel
IDC
EMI-filtered
Configuration of product Part No.
Mating connectors: PCR series cable-side IDC type or soldering type female connector
Accessories: Dust-proof cap, PCS-E( )C
Tool: (Refer to page Tool-12)
Cable-side IDC type male connector
for mounting on a panel
PCR-E( )PM( )
➀➁¢
PCR-E ( ) PM ( )
Components
Contacts
Insulator
Shell
Spacer
Cable housings
Series name
No. of contacts: 20, 28, 36, 50, 68 or 96
£ Type of connector: Panel mount type, male
¢ Cable sizes for reference purposes (In case the cable sheath is made of PVC resin)
PM : AWG#28(7 / 0.127) or AWG#30(1 / 0.254). Outside diameter of wire is 0.8-1 mm. For loose wire.
PMA: AWG#28(7 / 0.127) or AWG#30(1 / 0.254). Outside diameter of wire is 0.5-0.65 mm.
For loose wire.
PMB: AWG#30(7 / 0.1). Outside diameter of wire is 0.5-0.65 mm. For loose wire. (See Note #1)
PMC: AWG#28(7 / 0.127) or AWG#30(1 / 0.254). IDC for fusible cable. (See Note #1)
PMD: AWG#30(7 / 0.1). IDC for fusible cable. (See Note #2)
PCR-E20PM( )
PCR-E28PM( )
PCR-E36PM( )
PCR-E50PM( )
PCR-E68PM( )
PCR-E96PM( )
11.43
16.51
21.59
30.48
41.91
59.69
C
33.40
38.48
43.56
52.45
63.88
81.66
27.40
32.48
37.56
46.45
57.88
75.66
AB EF
23.80
28.90
34.00
42.90
54.60
72.10
G
16.45
21.53
26.61
35.50
46.93
64.71
H
13.20
18.28
23.36
32.25
43.68
61.46
21.60
26.68
31.76
40.65
52.08
69.86
21.65
26.70
31.80
40.70
52.10
69.90
D
15˚
G
B
¡
£
¡
¢
2-M2.5
R1.4
A
H
D
C
B
E
1.27
10.5
C
F
12.7
7.1
5.7
5.44.1
16
3.9
2.8
0.85 0.85
1.32
Panel mounting-hole dimensions
for reference purposes
Cable housing for loose wires
Cable housing for flat cable
7.5 MIN.
Recommended panel cut-out dimensions
Part No.
Dimensions
Note 1: PMB is not available for 28-contact connector.
PMC is not available for 96-contact connector.
Note 2: PMD is available only for 50 or 68-contact connectors.
Others
Wire
wrapping
CrimpingSolderingIDCPress-inSMT
Through
hole