New Product Slim I/O Relay Global standard size, low profile slim I/O relay with width 6.2 mm, slim I/O solid state relay For the recent information on models that have been certified for safety standards, refer to your OMRON website. Refer to Safety Precautions on page 20. Slim I/O Relay Types G2RV-SR series mounted relay: electromagnetic relay ...... from page 2 G3RV-SR series mounted relay: solid state relay ................ from page 10 Common matter Common Precautions * According to OMRON actual measurement data from November 2015. G3RV-SR * Realized about 25% lower profile than conventional products, contributing to further miniaturization of the control panel. * Push-In Plus technology are used to save wiring work in comparison with conventional screw terminals. (Wiring time is reduced by 60%* in comparison with traditional screw terminals.) * No screw loosening means maintenance-free application, realizing high reliability * `Hand-free' structure that holds an inserted flat-blade screwdriver to achieve easier wiring work for stranded wires. * Screw terminal is also stocked to meet the screw type needs. * Mounted relay or solid-state relay has a plug-in terminal that is difficult to bend at the time of exchange. G2RV-SR G2RV-SR/G3RV-SR Common precautions ................................................................ from page 20 Common accessories (order separately)................................. from page 25 Common Accessories 1 Slim I/O Relay G2RV-SR G2RV-SR Global standard size, low profile slim I/O relay with width 6.2 mm G3RV-SR * Realized about 25% lower profile than conventional products, contributing to further miniaturization of the control panel. * Realized opening and closing ability with one pole 6 A slim shape. * Micro load products for one pole 50 mA using Au-plated contacts for small load switching also available. * Since G2RV is a transparent case, confirming the state of the contact with the naked eye is possible, and easy to confirm abnormality on-site (installed location). For the recent information on models that have been certified * Screw terminal is also stocked to meet the screw type for safety standards, refer to your OMRON website. needs. * Mounted relay uses plug-in terminals that are difficult to bend when exchanging. * G3RV-SR featuring a solid state relay similar in shape to G2RV-SR also available. Refer to Safety Precautions on page 20. Common Precautions Features Terminal x 5 * Push-in * Screw Release lever Mechanical indicator * Operation verification which is linked to the contact Operation display LED (Socket section) Push-In Plus technology Protective cover (Released state) Protective cover (Locked condition) Latching lever (Test switch) Latching lever (Test switch) * Circuit check operation Confirmation, reducing the inspection effort PAT Common Accessories "Foreign matter intrusion prevention structure" "Malfunction prevention stopper" Transparent case Relay contact Easy confirmation of the situation Release lever Relay easily fixed/removed 90 mm 80 mm 2 With latching lever (Test switch) Standard model/Micro load Plug-in terminal Peace of mind as the terminal does not bend when replacing Short bar insertion holes Release hole Terminal (insertion) hole G2RV-SR Model Number Structure Model Number Legend (1) (2) (3) (4) (5) (6) (1) Basic model name G2RV: Slim I/O Relay (2) Sub type SR: Slim relay + integrated low profile socket (3) Terminal (wire connection) 50: Push-In Plus Terminal 70: Screw terminal (5) Contact structure Blank: Standard AP: Microloads (4) Latching lever (test switch) 0: Without latching lever 1: With latching lever (6) Rated input voltage 12, 24 VDC 24, 48 VAC/VC 100, 110, 200, 230 VAC G2RV-SR G2RV-SR @@ @ - @ @ Ordering Information Terminal (Wire connection) Latching lever (Test switch) Classification Rated input voltage (V) G2RV-SR500 DC24 24 G2RV-SR500 AC/DC24 48 G2RV-SR500 AC/DC48 100 G2RV-SR500 AC100 110 G2RV-SR500 AC110 200 G2RV-SR500 AC200 230 G2RV-SR500 AC230 DC 24 G2RV-SR501 DC24 AC/DC 24 G2RV-SR501 AC/DC24 12 G2RV-SR500-AP DC12 24 G2RV-SR500-AP DC24 24 G2RV-SR500-AP AC/DC24 AC/DC No Standard AC Yes DC AC/DC Microloads G2RV-SR500-AP AC/DC48 100 G2RV-SR500-AP AC100 110 G2RV-SR500-AP AC110 200 G2RV-SR500-AP AC200 230 G2RV-SR500-AP AC230 12 G2RV-SR700 DC12 24 G2RV-SR700 DC24 24 G2RV-SR700 AC/DC24 48 G2RV-SR700 AC/DC48 100 G2RV-SR700 AC100 110 G2RV-SR700 AC110 200 G2RV-SR700 AC200 230 G2RV-SR700 AC230 DC 24 G2RV-SR701 DC24 AC/DC 24 G2RV-SR701 AC/DC24 12 G2RV-SR700-AP DC12 24 G2RV-SR700-AP DC24 24 G2RV-SR700-AP AC/DC24 No AC DC AC/DC No Standard AC Yes Screw terminal DC AC/DC Microloads No AC Note: Sockets are not sold individually. 48 G2RV-SR700-AP AC/DC48 100 G2RV-SR700-AP AC100 110 G2RV-SR700-AP AC110 200 G2RV-SR700-AP AC200 230 G2RV-SR700-AP AC230 Common Accessories 48 Common Precautions G2RV-SR500 DC12 24 G3RV-SR 12 DC Push-In Plus Terminal Model 3 G2RV-SR Relay for Maintenance G2RV-SR Model Number Legend G2RV-1 - S @ - @ - G @ (1) (2) (3) (4) (5) (1) No. of poles 1: 1 pole G2RV-1-SI-G G2RV-1-S(-AP)-G (6) (4) Contact material Blank: Ag alloy AP: Ag alloy + Au plating (2) Terminal S: plug-in (3) Latching lever (Test switch) Blank: Without latching lever I: With latching lever (5) Types of relay for exchange G: G2RV-SR series equipped Relay (6) Rated coil voltage Number: 11, 21, 48 VDC List of Models G3RV-SR Type Latching Lever (Test switch) No Rated coil voltage (V) Model 11 G2RV-1-S-G DC11 21 G2RV-1-S-G DC21 G2RV-SR700/500 DC12V G2RV-SR700/500 DC24V G2RV-SR700/500 AC/DC24V G2RV-SR700/500 AC/DC48V DC Standard Applicable model G2RV-SR700/500 AC100V 48 G2RV-1-S-G DC48 G2RV-SR700/500 AC110V G2RV-SR700/500 AC200V G2RV-SR700/500 AC230V Common Precautions Yes Microload No DC 21 G2RV-1-SI-G DC21 11 G2RV-1-S-AP-G DC11 21 G2RV-1-S-AP-G DC21 G2RV-SR701/501 AC/DC24V G2RV-SR700/500-AP DC12V G2RV-SR700/500-AP DC24V G2RV-SR700/500-AP AC/DC24V G2RV-SR700/500-AP AC/DC48V DC G2RV-SR700/500-AP AC100V 48 G2RV-1-S-AP-G DC48 G2RV-SR700/500-AP AC110V G2RV-SR700/500-AP AC200V G2RV-SR700/500-AP AC230V Note: Voltage is reduced within the socket for the slim I/O relay, so the rated input voltage and rated coil voltage of replacement relays are different. Accessories (order separately) Refer to page 25 for G2RV-SR/G3VR-SR Common Accessories. Common Accessories 4 G2RV-SR701/501 DC24V G2RV-SR Specifications Ratings Must operate voltage Rated current Rated input voltage AC 50 Hz DC 60 Hz Must release voltage Percentage of the rated voltage Power consumption Maximum allowable voltage AC (VA) Percentage of the rated voltage DC (mW) 12 VDC - - 27.9 mA - Approx. 300 mW 24 VDC - - 13.5 mA - Approx. 300 mW 24 VAC/VDC 12.5 mA 12.6 mA 12.6 mA Approx. 0.5 VA Approx. 300 mW 48 VAC/VDC 5.9 mA 6.1 mA 5.2 mA 100 VAC 5.9 mA 6.0 mA - 110 VAC 5.9 mA 5.9 mA - Approx. 0.8 VA - 200 VAC 6.6 mA 7.6 mA - Approx. 1.7 VA - 230 VAC 7.3 mA 8.4 mA - Approx. 1.7 VA - 80% max.* Approx. 0.4 VA Approx. 250 mW 10% min. Approx. 0.8 VA - 110% Contact ratings Standard (G2RV-SR700, 500, 701, 501) For microloads (G2RV-SR700-AP, 500-AP) *2 SPDT Load Resistive load (cos=1) Inductive load (cos=0.4, L/R=7ms) Resistive load (cos=1) Rated load 6 A at 250 VAC 6 A at 30 VDC 2.5 A at 250 VAC 2 A at 30 VDC 50 mA at 30 VAC 50 mA at 36 VDC Rated carry current 6A 50 mA Maximum switching voltage 440 VAC, 125 VDC 30 VAC, 36 VDC Maximum switching current 6A Maximum switching power 1,500 VA 180 W Failure rate P value (reference value) *1 10 mA at 5 VDC 50 mA 500 VA 60 W - 1 mA at 100 mVDC *1. P level: 60=0.1x10 /times This value is the value in switching frequency 120 operations/min. *2. If the Au plating layer is destroyed, the number will be the same as the standard type. -6 Characteristics Item Standard (G2RV-SR700, 500, 701, 501) For microloads (G2RV-SR700-AP, 500-AP) 100 m max. Operate (Set) time * 20 ms max. Release time * AC, AC/DC: 40 ms max. DC: 20 ms max. Maximum operating frequency Mechanical: 18,000 operations/h Electrical: 1,800 operations/h (rated load) Insulation resistance 1,000 M min. (at 500 VDC) Dielectric strength Between coil and contacts: 4,000VAC 50/60 Hz 1 min Contact between the same polarity: 1,000 VAC 50/60 Hz 1 min Vibration resistance Destruction: 10 to 55 to 10 Hz, single amplitude 0.50 mm (double amplitude 1.0 mm) Malfunction: 10 to 55 to 10 Hz, single amplitude 0.50 mm (double amplitude 1.0 mm) Shock resistance Destruction: 1,000 m/s2 Malfunction: Energized 200m/s2, Non-energized 100m/s2 Endurance * Mechanical 5,000,000 operations min. Electrical NO contact: 70,000 operations min. NC contact: 50,000 operations min. 5,000,000 operations min. Ambient operating temperature Operating: -40 to +55C (with no icing or condensation) Ambient operating humidity Operating: 5 to 85% RH Weight Approx. 30 g Contact material Ag alloy Common Accessories Contact resistance * Common Precautions Contact configuration G3RV-SR Note: The operating characteristics are measured at ambient temperature of 23C. * Operating voltage will be, for mounting in the upside down direction, 85% max. (Upside down: Direction in which the mechanical indicator faces down) Item G2RV-SR Coil ratings Ag alloy + Au plating Note: Above values are initial values. * Value is at ambient temperature of 23C. 5 G2RV-SR Approved standards G2RV-SR UL508 (file No.E41643) Model Contact form G2RV-SR series Operation coil ratings 12 to 48 VDC 24 to 230 VAC SPDT Contact ratings Operations 6 A at 250 VAC (Resistive load) 6 A at 30 VDC (Resistive load) 2 A at 400 VAC (Resistive load)* * If the load voltage exceeds 250 VAC, please attach with a spacing of 12 mm min., or use a separate plate (XW5Z-EP12). 6,000 12 mm 12 mm 12 mm TUV (EN 61810-1) \ Model Contact form SPDT Operations 50,000 50,000 6,000 12 mm 12 mm 12 mm Model Contact form Operation coil ratings Contact ratings 6 A at 250 VAC (Resistive load) G2RV-SR500 G2RV-SR700 12, 24 VDC 24, 48 VAC/VDC 100, 110, 200, 230 VAC SPDT 2.5 A at 250 VAC (PF0.4) 6 A at 30 VAC (Ress) 2 A at 30 VDC (L/R=7ms) 6 A at 250 VAC (Resistive load) G2RV-SR501 G2RV-SR701 SPDT 12, 24 VDC 24 VAC/VDC SPDT 12, 24 VDC 24, 48 VAC/VDC 100, 110, 200, 230 VAC 2.5 A at 250 VAC (PF0.4) 6 A at 30 VAC (Ress) 2 A at 30 VDC (L/R=7ms) G2RV-SR500-AP G2RV-SR700-AP 0.05 A at 30 VAC (Resistive load) 0.05 A at 36 VDC (Resistive load) Common Accessories Engineering Data Endurance curve (N.O. side) Switching capacity of DC resistive load 1000 30 VDC resistive load 250 VAC resistive load DC breaking current (A) Common Precautions Lloyd's (File No.07/10020) 10.0 1.0 100 30 VDC inductive load 250 VAC inductive load 10 0 0.1 2 4 6 Opening and closing current (A) 6 Contact ratings 6 A at 250 VAC (Resistive load) 6 A at 30 VDC (Resistive load) 2 A at 400 VAC (Resistive load)* * If the load voltage exceeds 250 VAC, please attach with a spacing of 12 mm min., or use a separate plate (XW5Z-EP12). Number of operations (x 103 operations) G3RV-SR G2RV-SR series Operation coil ratings 12, 24 VDC 24, 48 VAC/VDC 100, 110, 200, 230 VAC 20 60 100 140 180 220 DC switching voltage (V) G2RV-SR Dimensions (unit: mm) Slim I/O Relay + socket Push-In Plus Terminal Block Terminal Arrangement/Internal Connection Diagram (TOP VIEW) 12 VDC (+) Input circuit A1 G2RV-SR Models without latching lever (without test switch) G2RV-SR500 78 max. G2RV-SR500-AP A2 G2RV 3.4 (-) 74.5 74.1 Other voltage 35.25 18.78 (5.05) Input circuit A1 G2RV 12 A2 14 11 78.77 G3RV-SR 90 max. 35.3 24 VDC (+) Input circuit 12 A1 14 A2 G2RV 11 (-) : Diode bridge (5.05) : Light emitting diode 18.78 6.2 max. 35.25 51.72 59.71 12 14 Models with latching lever (with test switch) G2RV-SR501 Terminal Arrangement/Internal Connection Diagram (TOP VIEW) 12 VDC 81 max. (+) Input circuit A1 A2 G2RV 3.4 (5.05) (-) 77.5 74.1 Other voltage 35.25 18.78 Input circuit A1 G2RV 12 A2 11 78.77 24 VDC 90 max. (+) A1 A2 G2RV (-) Input circuit 12 14 11 : Diode bridge (5.05) : Light emitting diode 18.78 6.2 max. 35.25 51.72 59.71 12 Common Accessories 14 35.3 Common Precautions 11 14 11 7 G2RV-SR Screw terminal G2RV-SR Models without latching lever (without test switch) G2RV-SR700 G2RV-SR700-AP Terminal Arrangement/Internal Connection Diagram (TOP VIEW) 12 VDC (+) 78 max. G2RV 3.4 Input circuit A1 74.5 A2 (-) Other voltage 74.1 35.18 Input circuit 18.71 (5.05) A1 G2RV 12 A2 14 11 78.77 35.3 90 max. G3RV-SR 24 VDC (+) Input circuit 12 A1 14 A2 G2RV 11 (-) : Diode bridge (5.05) 18.71 : Light emitting diode 35.18 6.2 max. 51.65 56.2 12 14 Common Precautions 11 Models with latching lever (with test switch) G2RV-SR701 Terminal Arrangement/Internal Connection Diagram (TOP VIEW) 12 VDC (+) 81 max. Input circuit A1 G2RV 3.4 A2 (-) 77.5 Other voltage 74.1 35.18 (5.05) Input circuit 18.71 A1 G2RV 12 A2 14 Common Accessories 11 78.77 35.3 24 VDC 90 max. (+) A1 A2 G2RV (-) 12 14 11 : Diode bridge (5.05) 18.71 : Light emitting diode 35.18 6.2 max. 51.65 56.2 12 14 11 8 Input circuit G2RV-SR Relay for maintenance 5.2 max. G2RV-SR Models without latching lever G2RV-1-S-G G2RV-1-S-AP-G 30.5 max. Terminal Arrangement/ Internal Connection Diagram (TOP VIEW) 33 max. 16.2 0.5 14 11 12 A1 A2 G3RV-SR 1.8 (Input circuit) 2.4 3.5 5.04 5.04 22 3 Models with latching lever (test switch) G2RV-1-SI-G 30.5 max. Terminal Arrangement/ Internal Connection Diagram (TOP VIEW) (Input circuit) 36 max. 14 11 12 16.2 1.8 A1 A2 Common Precautions 5.2 max. 0.5 2.4 5.04 5.04 22 3 Common Accessories 3.5 9 Slim I/O Solid State Relay G2RV-SR G3RV-SR Global standard size, low profile type slim I/O solid state relay with width 6.2 mm. G3RV-SR * Realized about 25% lower profile than conventional products, contributing to further miniaturization of the control panel. * Optimal slim, high frequency, high-speed opening and closing SSR (solid state relay). * Realized a slim shape with a switching capacity up to 3 A (DC), and 2 A (AC). * Because MOSFET is used for the outlet element for the DC load, opening and closing load of 100 A to 3 A is possible. * Check operating status at a glance at the operating display LED. For the recent information on models that have been certified * Mounted I/O SSR (solid-state relay) uses plug-in terminals that for safety standards, refer to your OMRON website. are difficult to bend when exchanging. * G2RV-SR featuring a general-purpose relay similar in shape to G3RV-SR also available. Refer to Safety Precautions on page 20. Common Precautions Features Common Accessories 10 Push-In Plus technology Terminal x 5 * Push-in * Screw Short bar insertion holes Release lever Operation display LED (Socket section) Release hole Operation display LED (SSR section) Terminal (insertion) hole Release lever Relay easily fixed/removed 90 mm 80 mm Plug-in terminal Peace of mind as the terminal does not bend when replacing G3RV-SR Model Number Structure Model Number Legend (1) (2) (3) (4) (5) (1) Basic model name G3RV: Slim I/O Solid State Relay (2) Sub type SR: Slim solid relay + integrated low profile socket (3) Terminal (wire connection) 500: Push-In Plus Terminal 700: Screw terminal (4) Output voltage specification A : AC output (triac) zero cross function available AL : AC output (triac) zero cross function not available D : DC output (MOS FET) G2RV-SR G3RV-SR @ @ @ - @ @ (5) Rated voltage input 12, 24 VDC 24, 48 VAC/VDC 100, 110, 200, 230 VAC G3RV-SR Common Precautions Common Accessories 11 G3RV-SR Ordering Information Terminal (wire connection) Applicable output load Zero cross function Rated input voltage (V) G2RV-SR DC AC/DC DC load -- AC DC AC/DC Push-In Plus Terminal Yes G3RV-SR AC AC load DC AC/DC No AC Common Precautions DC AC/DC DC load -- AC DC AC/DC Screw terminal Yes Common Accessories AC AC load DC AC/DC No AC Note: Sockets are not sold individually. 12 Model 12 G3RV-SR500-D DC12 24 G3RV-SR500-D DC24 24 G3RV-SR500-D AC/DC24 48 G3RV-SR500-D AC/DC48 100 G3RV-SR500-D AC100 110 G3RV-SR500-D AC110 200 G3RV-SR500-D AC200 230 G3RV-SR500-D AC230 12 G3RV-SR500-A DC12 24 G3RV-SR500-A DC24 24 G3RV-SR500-A AC/DC24 48 G3RV-SR500-A AC/DC48 100 G3RV-SR500-A AC100 110 G3RV-SR500-A AC110 200 G3RV-SR500-A AC200 230 G3RV-SR500-A AC230 12 G3RV-SR500-AL DC12 24 G3RV-SR500-AL DC24 24 G3RV-SR500-AL AC/DC24 48 G3RV-SR500-AL AC/DC48 100 G3RV-SR500-AL AC100 110 G3RV-SR500-AL AC110 200 G3RV-SR500-AL AC200 230 G3RV-SR500-AL AC230 12 G3RV-SR700-D DC12 24 G3RV-SR700-D DC24 24 G3RV-SR700-D AC/DC24 48 G3RV-SR700-D AC/DC48 100 G3RV-SR700-D AC100 110 G3RV-SR700-D AC110 200 G3RV-SR700-D AC200 230 G3RV-SR700-D AC230 12 G3RV-SR700-A DC12 24 G3RV-SR700-A DC24 24 G3RV-SR700-A AC/DC24 48 G3RV-SR700-A AC/DC48 100 G3RV-SR700-A AC100 110 G3RV-SR700-A AC110 200 G3RV-SR700-A AC200 230 G3RV-SR700-A AC230 12 G3RV-SR700-AL DC12 24 G3RV-SR700-AL DC24 24 G3RV-SR700-AL AC/DC24 48 G3RV-SR700-AL AC/DC48 100 G3RV-SR700-AL AC100 110 G3RV-SR700-AL AC110 200 G3RV-SR700-AL AC200 230 G3RV-SR700-AL AC230 G3RV-SR Solid state relay for maintenance G2RV-SR Model Number Legend G3RV-@ @ S @ @ (1) (2) (3) (4) (1) Output voltage specification D: DC output 2: AC output (5) (3) Terminal S: Plug-in type (4) Zero cross functions Blank: Zero cross function available L: Zero cross function not available (2) Rated current 02: AC output 2 A 03: DC output 3 A (5) Rated input voltage Number: 12, 24, 48 VDC List of Models Rated output Load * Rated input voltage (socket) 12 VDC 24 VDC 24 VAC/VDC Model G3RV-202S DC12 G3RV-202S DC24 48 VAC/VDC Yes Phototriac AC Yes (green) G3RV-SR700/500-A AC200V G3RV-SR700/500-A AC230V G3RV-202SL DC12 G3RV-202SL DC24 48 VAC/VDC No 24 VAC/VDC Photovoltage coupler DC - 3A (at 5 to 24 VDC) G3RV-SR700/500-AL AC230V G3RV-D03SL DC12 G3RV-D03SL DC24 48 VAC/VDC G3RV-SR700/500-D DC12V G3RV-SR700/500-D DC24V G3RV-SR700/500-D AC/DC24V G3RV-SR700/500-D AC/DC48V 100 VAC 110 VAC G3RV-SR700/500-AL AC110V G3RV-SR700/500-AL AC200V 230 VAC 24 VDC G3RV-SR700/500-AL DC24V G3RV-SR700/500-AL AC/DC24V G3RV-SR700/500-AL AC100V G3RV-202SL DC48 200 VAC 12 VDC G3RV-SR700/500-AL DC12V G3RV-SR700/500-AL AC/DC48V 100 VAC 110 VAC G3RV-SR700/500-A AC110V G3RV-SR700/500-D AC100V G3RV-D03SL DC48 G3RV-SR700/500-D AC110V G3RV-SR700/500-D AC200V 230 VAC G3RV-SR700/500-D AC230V * Different depending on the ambient temperature. For more details, refer to Load current vs. ambient rated temperature on page 16. Refer to page 25 for G2RV-SR/G3VR-SR Common Accessories. Common Accessories 200 VAC Accessories (order separately) Common Precautions 24 VAC/VDC G3RV-SR700/500-A DC24V G3RV-SR700/500-A AC/DC24V G3RV-SR700/500-A AC100V G3RV-202S DC48 200 VAC 2A (at 100 to 230 VAC 240 12 VDC VAC) 24 VDC G3RV-SR700/500-A DC12V G3RV-SR700/500-A AC/DC48V 100 VAC 110 VAC Applicable model G3RV-SR Insulation Operation Output Zero cross method Display (SSR) Function 13 G3RV-SR Specifications Rating (ambient temperature 25C) G2RV-SR Input G3RV-SR700/500-A series Rated current Rated input voltage AC 50 Hz DC 60 Hz Must operate voltage 12 VDC - - 15.0 mA 10.8 V max. 24 VDC - - 12.0 mA 21.6 V max. 24 VAC/VDC 11.3 mA 11.4 mA 11.0 mA 21.6 V max. 48 VAC/VDC 6.8 mA 6.9 mA 6.0 mA 43.2 V max. 100 VAC 6.2 mA 6.2 mA - 90 V max. 110 VAC 6.2 mA 6.2 mA - 99 V max. 200 VAC 6.7 mA 7.9 mA - 180 V max. 230 VAC 7.5 mA 8.8 mA - 207 V max. Must release voltage 1 V min. Input voltage Percentage of the rated voltage 10% G3RV-SR G3RV-SR700/500-AL series Rated current Rated input voltage 12 VDC AC 50 Hz - DC 60 Hz - Must operate voltage 15.0 mA 10.8 V max. 24 VDC - - 12.0 mA 21.6 V max. 24 VAC/VDC 11.4 mA 11.5 mA 11.0 mA 21.6 V max. Common Precautions 48 VAC/VDC 7.7 mA 7.7 mA 6.9 mA 43.2 V max. 100 VAC 7.3 mA 7.3 mA - 90 V max. 110 VAC 7.3 mA 7.3 mA - 99 V max. 200 VAC 7.0 mA 8.1 mA - 180 V max. 230 VAC 7.7 mA 8.9 mA - 207 V max. Must release voltage 1 V min. Input voltage Percentage of the rated voltage 10% G3RV-SR700/500-D series Rated current Rated input voltage AC 50 Hz DC 60 Hz Must operate voltage Common Accessories 12 VDC - - 8.0 mA 10.8 V max. 24 VDC - - 4.6 mA 21.6 V max. 24 VAC/VDC 5.0 mA 5.1 mA 4.3 mA 21.6 V max. 48 VAC/VDC 6.8 mA 6.9 mA 6.0 mA 43.2 V max. 100 VAC 6.2 mA 6.2 mA - 90 V max. 110 VAC 6.2 mA 6.2 mA - 99 V max. 200 VAC 6.7 mA 7.9 mA - 180 V max. 230 VAC 7.5 mA 8.8 mA - 207 V max. Must release voltage 1 V min. Input voltage Percentage of the rated voltage 10% Output 14 Item G3RV-SR700/500-A(L) G3RV-SR700/500-D Rated load voltage 100 to 240 VAC (50/60 Hz) 5 to 24 VDC Load voltage range 75 to 264 VAC (50/60 Hz) 3 to 26.4 VDC Load current 0.1 to 2 A (Ambient temperature=25C) 100 A to 3 A (Ambient temperature=25C) Inrush current resistance 30 A (60 Hz, 1 cycle) 30 A (60 Hz, 1 cycle) Permissible l2t; Joule integral value (reference value) 15A2s 9 A2 s Applied load capacity 400 W (Output voltage: 200 VAC) 72 W (Output voltage: 24 VDC) G3RV-SR Characteristics G3RV-SR700/500-A G3RV-SR700/500-AL G3RV-SR700/500-D Operate time 1/2 cycle of load power supply +1 ms max. 3 ms max. 6 ms max. Release time 60 ms max. 60 ms max. 60 ms max. Output ON voltage drop 1.6 V (RMS) max. Output ON resistance - 0.3 max. (at 24 VDC) - 5 mA max. (at 200 VAC, 50/60 Hz) 10 A max. (at 24 VDC) Insulation resistance 100 M min. (at 500 VDC) Dielectric strength Between input and output 2,500 VAC 50/60 Hz 1 min Vibration resistance Malfunction: 10 to 55 to 10 Hz double amplitude 0.70 mm Shock resistance 300m/s2 Ambient operating temperature Storage: -30 to +100C (with no icing or no condensation) Operating: -30 to +55C (with no icing or no condensation) Ambient operating humidity 45 to 85% RH Weight Approx. 38 g Pollution degree 2 The degree of protection by IEC60529 IP20 Rated impulse dielectric strength 4.0 kV/III Load category LC-A Overload current profile 1.5Ie 1.1Ue 5s ON, 10s OFF, 10 cycles Rated insulation voltage 240 V G3RV-SR Leaked current DC-12 UL 508 (file No.E64562) Input ratings Contact ratings G3RV-SR700/500-D series 12, 24 VDC 24, 48 VAC/VDC 100, 110, 200, 230 VAC 24 VDC 3 A (resistive load) at 25C G3RV-SR700/500-A(L) series 12, 24 VDC 24, 48 VAC/DC 100, 110, 200, 230 VAC 240 VAC 2 A (resistive load) at 25C TUV(EN 62314) Model Input ratings Contact ratings 12, 24 VDC 24, 48 VAC/VDC 100, 110, 200, 230 VAC 24 VDC 3 A (resistive load) G3RV-SR700/500-A(L) series 12, 24 VDC 24, 48 VAC/VDC 100, 110, 200, 230 VAC 240 VAC 2 A (resistive load) Common Accessories G3RV-SR700/500-D series Common Precautions Approved standards Model G2RV-SR Item 15 G3RV-SR Engineering Data Load current vs. ambient rated temperature Product mounting spacing 10 mm (Separate Mounting) Close mounting (up to 5 units *) 5 Load current (A) Load current (A) G2RV-SR G3RV-SR700/500-A(L) series 4 5 4 3 3 2 2 1 1 0 -30 -20 0 20 25 40 55 60 80 0.2 0 -30 -20 100 0 20 25 Ambient temperature (C) 40 55 60 80 100 Ambient temperature (C) Close mounting (up to 5 units *) Load current (A) Load current (A) Product mounting spacing 10 mm (Separate Mounting) 5 4 5 4 3 3 2 2 1 0.5 0 -30 -20 0 20 25 40 55 60 80 0 -30 -20 100 0 20 25 Ambient temperature (C) 40 55 60 80 100 Ambient temperature (C) * When five or more are installed, install with 10 mm space between each. For details, please refer to Mounting on page 23. Inrush Current Resistance: Non-repetitive Keep the inrush current to below the inrush current resistance value (i.e., below the broken line) if it occurs repetitively. Common Accessories 16 G3RV-SR700/500-A(L) series G3RV-SR700/500-D series 40 Inrush current (A.Peak) Common Precautions 1 Inrush current (A.Peak) G3RV-SR G3RV-SR700/500-D series 35 30 25 40 35 30 25 20 20 15 15 10 10 5 5 0 10 30 50 100 300 500 1,000 3,000 5,000 Energized time (ms) 0 10 30 50 100 300 500 1,000 3,000 5,000 Energized time (ms) G3RV-SR Dimensions (unit: mm) Solid state relay + socket Terminal Arrangement/ Internal Connection Diagram (TOP VIEW) 12 VDC G2RV-SR Push-In Plus Terminal Block G3RV-SR500 (+) Input circuit 78 max. A1 G3RV A2 A2- 3.4 (5.05) (-) INPUT 74.5 74.1 A1+ 13 (+) 35.25 18.78 OUTPUT 14 (-) 12 14 13 78.77 24 VDC 90 max. 35.3 (+) Input circuit G3RV-SR The information in parentheses in for a DC output. A1 G3RV A2 (-) A2- INPUT (5.05) A1+ 18.78 6.2 max. 35.25 OUTPUT 14 (-) 59.71 The information in parentheses in for a DC output. 12 14 13 Other voltage Input circuit A1 G3RV A2 A2- Common Precautions 51.72 13 (+) INPUT A1+ 13 (+) 14 (-) The information in parentheses in for a DC output. 12 14 13 : Diode bridge : Light emitting diode Common Accessories OUTPUT 17 G3RV-SR Screw terminal G3RV-SR700 G2RV-SR Terminal Arrangement/ Internal Connection Diagram (TOP VIEW) 12 VDC 78 max. (+) Input circuit A1 3.4 74.5 G3RV 74.1 35.18 (5.05) A2 A2- 18.71 (-) INPUT A1+ 13 (+) OUTPUT 14 (-) G3RV-SR 78.77 35.3 90 max. The information in parentheses in for a DC output. 12 14 13 24 VDC (+) Input circuit A1 (5.05) 18.71 G3RV 35.18 A2 6.2 max. (-) 51.65 56.2 A2- INPUT A1+ 13 (+) Common Precautions OUTPUT 14 (-) The information in parentheses in for a DC output. 12 14 13 Other voltage Input circuit A1 G3RV A2 A2- INPUT A1+ 13 (+) Common Accessories 18 OUTPUT 14 (-) The information in parentheses in for a DC output. 12 14 13 : Diode bridge : Light emitting diode G3RV-SR Solid state relay for maintenance Terminal Arrangement/ Internal Connection Diagram (TOP VIEW) G3RV-D03SL (input circuit) Input 30.5 max. Load G2RV-SR G3RV-D03SL G3RV-202S(L) 33 max. 15.8 14 1.8 3.5 13 A1 A2 G3RV-202S(L) (input circuit) 2.4 22 5.04 3 Input 5.2 max. Load 13 A1 A2 G3RV-SR 14 Common Precautions Common Accessories 19 G2RV-SR/G3RV-SR Safety Precautions Be sure to read the Safety Precautions for All Relays in the website at the following URL: http://www.ia.omron.com/. G2RV-SR Format of Warning Indications WARNING Indicates a potentially hazardous situation which, if not avoided, will result in minor or moderate injury, or may result in serious injury or death. Additionally, there may be significant property damage. CAUTION Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury or in property damage. Precautions for Safe Use Indicates supplementary comments on what to do or avoid doing, to use the product safety. Precautions for Correct Use Includes operating precautions to ensure that the product will operate properly and that performance and functions will not be adversely affected. G3RV-SR Meaning of Graphic Symbols for Ensuring Product Safety Indicates the possibility of electric shock under specific conditions. Used for general CAUTION, WARNING, or DANGER precautions for which there is no specified symbol. (This symbol is also used as the alerting symbol, but shall not be used in this meaning on the product.) Indicates the possibility of explosion or rupture under specific conditions. Common Precautions Common Accessories 20 Indicates the possibility of injuries by high temperature under specific conditions. WARNING Ensure that the socket is not charged during wiring and maintenance. Not doing so may result in electric shock. Do not touch the terminal section of the G2RV-SR or the surrounding area while the power is being supplied. Doing so may result in electric shock. CAUTION Minor electrical shock may occasionally occur. Do not touch the G3RV terminal section (i.e., current carrying parts) while the power is being supplied. The G3RV may rupture if short-circuit current flows. As protection against accidents due to short-circuiting, be sure to install protective devices, such as fuses and no-fuse breakers, on the power supply side. Minor electrical shock may occasionally occur. Do not touch the main circuit terminals on the G3RV immediately after the power supply has been turned OFF. Shock may result due to the electrical charge stored in the built-in snubber circuit. Note: G3RV-202S(L), G3RV-SR500/700-A(L) series models only Minor burns may occasionally occur. Do not touch the G3RV or the heat sink while the power is being supplied or immediately after the power supply has been turned OFF. The G3RV becomes extremely hot. Provide a space of at least 3 mm between the G2RVSR and ground. Not doing so may result in a ground fault. G2RV-SR/G3RV-SR Precautions for Safe Use G2RV-SR Transport * Do not use the product if it has been dropped on the ground. Dropping the product may adversely affect performance. * Do not drop the product or subject it to abnormal vibration or shock during transportation or mounting. Doing so may result in deterioration of performance, malfunction, or failure. * Do not transport the product without it being packaged. Doing so may result in damage, malfunction, or failure. * Do not transport the G3RV under the following conditions. Doing so may result in damage, malfunction, or deterioration of performance characteristics. * High temperature, high humidity conditions * Conditions such as temperature change that causes rapid condensation * Condition where it is not packaged * Do not use or store the product in the following locations. Doing so may result in damage, malfunction, or deterioration of performance characteristics. * Do not store in locations subject to ambient storage temperatures outside the range -40 to 70C (for G2RV) and outside the range -30 to 100C (for G3RV). * Locations subject to relative humidity outside the range 5% to 85% (for G2RV) and outside the range 45% to 85% (for G3RV). * Locations subject to high temperature or high humidity. * Conditions such as temperature change that causes rapid * Locations where corrosive gases or flammable gases are present * Location where rainwater or water droplets gets splashed * Location with splashes of water, oil, and chemicals, etc. * Locations with much dust, salt, and iron powder * Location with blockers * Where static electricity or noise occurs in damage, malfunction, or failure. * Please use the power of the rated frequency. It may cause malfunction, failure, or risk of burnout. * Install G3RV according to instructions Mounting on page 23. If you install in the wrong direction, abnormal heat is generated, and may lead to short-circuiting or burning the output element. * G3RV is an SSR that generates heat. Please observe the ambient temperature setting range of G3RV. If installing in an enclosed space, set a fan, and ventilate. * When mounting G3RV to DIN rail, firmly fits into the groove. If it is not properly installed, there is a risk of it falling. Wiring * For the current to be applied, make sure a wire size with margin is used. Otherwise, excessive heat generated by the wires may cause burning. * Do not attempt to use the wire if the coat is torn. Not doing so may result in electric shock. * Always turn OFF the power supply before performing wiring. Not doing so may cause electrical shock. * The wires of the socket for G3RV socket should not be passed through the same duct as that being connected to the high-voltage power supply. Otherwise, inductive noise may damage the G3RV or cause it to malfunction. Push-In Plus Terminal Block * Where strong electromagnetic field is generated * Do not wire anything to the release holes. * Where there is a risk of exposure to radioactivity * Do not tilt or twist a flat-blade screwdriver while it is inserted into a release * Do not use or store Sockets in environments that contain silicone gas, sulfidizing gas (e.g., SO2 or H2S), or organic gas, or near materials that contain silicone. Doing so may cause the contacts to be unstable or to fail. Handling * Keep the G3RV well ventilated. overheating. Mounting * Before you start wiring, please make sure that the socket is securely attached to the mounting rail. If the socket is unstable, it may come loose and risk of injury towards the workers. * Please insert the flat-blade screwdriver to the bottom of the hole. If you do not insert the flat-blade screwdriver correctly, the cable will not be connected correctly. * When lubricant such as oil is attached to the tip of the driver, the driver will fall off, with a risk of injury towards the workers. * Do not tilt the G2RV-SR/G3RV-SR after mounting to the support The terminal block may be damaged if you insert the screwdriver straight in. * Do not allow the flat-blade screwdriver to fall out while it is inserted into a release hole. * Do not bend the wire past its natural bending radius or pull on it with excessive force. Doing so may cause the wire disconnection. * Do not insert more than one wire into each terminal (insertion) hole. * To prevent wiring materials from smoking or ignition, confirm wire ratings and use the wiring materials given in the following table. Recommended Wire Stripping length (Ferrules not used) 0.5 to 1.5 mm2/AWG20 to AWG16 8 mm Disposal * When disposing of the product, do not put into the fire. Common Accessories There is a risk of short-circuiting or burning due to G3RV hole on the terminal block. The terminal block may be damaged. * Insert a flat-blade screwdriver into the release holes at an angle. Common Precautions condensation * Please select the load within the rated range. Doing so may result G3RV-SR Operating and Storage Environments Usage rail. Doing so may apply excessive force to the mounting portion, possibly damaging the product. Attach end plates (PFP-M) to sandwich the product and hold it in place. 21 G2RV-SR/G3RV-SR Precautions for Correct Use G2RV-SR * Do not use or store the product in the following locations. Doing so * When replacing relays, there is a possibility the relay will pop out may result in damage, malfunction, or deterioration of performance and fall. Take care to prevent the relay from falling during characteristics. replacement. * Where vibration or shock is directly transmitted to the body * Where the socket could come into contact with a solvent or alkaline agent * Insert the short bar into the insertion hole in the correct orientation, Push-In Plus Terminal Block 1. Connecting Wires to the Push-In Plus Terminal Block Part Names of the Terminal Block and insert until all terminals are all the way in. * If using a short bar, install the short bar before performing wiring Release hole work. Terminal (Insertion) hole * A push-in Plus terminal block type and a screw terminal type have different insertion positions, so a mixed installation using the same short bar is not possible. G3RV-SR Connecting Wires with Ferrules and Solid Wires Insert the solid wire or ferrule straight into the terminal block until the end strikes the terminal block. Orient correctly and push all the way in. Release hole Terminal (Insertion) hole Completely inserted All terminals are inserted all the way in. Ferrules or solid wire * If a wire is difficult to connect because it is too thin, use a flat-blade screwdriver in the same way as when connecting stranded wire. Common Precautions Connecting Stranded Wires Use the following procedure to connect the wires to the terminal block. (1) Hold a flat-blade screwdriver at an angle and insert it into the release hole. The angle should be between 10and15. If the flat-blade screwdriver is inserted correctly, you will feel the spring in the release hole. (2) With the flat-blade screwdriver still inserted into the release hole, insert the wire into the terminal hole until it strikes the terminal block. (3) Remove the flat-blade screwdriver from the release hole. Incorrect installation Some terminals not inserted completely. Incomplete insertion All terminals are not inserted all the way in. (1) (3) Flat-blade screwdriver 10 to 15 (3) (1) (2) Incomplete insertion Stranded Wires (2) Checking Connections * After the insertion, pull gently on the wire to make sure that it will not come off and the wire is securely fastened to the terminal block. Common Accessories * If you use a ferrule with a conductor length of 10 mm, part of the conductor may be visible after the ferrule is inserted into the terminal block, but the product insulation distance will still be satisfied. * Do not insert short bar in the hole for wire or screw driver, it may cause the result of failure of pull out. If insert short bar in the hole for wire or screw driver and try to pull out, it may cause damage for short bar or socket and failure in electric conductivity. * Please insert P2RVC terminal into the short bar insertion hole of G2RV-SR/G3RV-SR. If insert P2RVC into the release hole or terminal (insertion) hole wrongly, P2RVC may stuck and can not remove and it may cause result of damage on P2RVC and G2RVSR/G3RV-SR. 2. Removing Wires from the Push-In Plus Terminal Block Use the following procedure to remove wires from the terminal block. The same method is used to remove stranded wires, solid wires, and ferrules. (1) Hold a flat-blade screwdriver at an angle and insert it into the release hole. (2) With the flat-blade screwdriver still inserted into the release hole, remove the wire from the terminal insertion hole. (3) Remove the flat-blade screwdriver from the release hole. (1) (3) Flat-blade screwdriver Please turn off the power of input and output side and remove PLC 10 to 15 (3) (1) interface unit when replacing mounting relays and SSRs for maintenance. 22 (2) Wire (2) G2RV-SR/G3RV-SR Screw Terminal 3. Recommended ferrules and Crimp Tools Recommended ferrules * Screw terminal Stripping Ferrules Recommended ferrules length Conduct (mm) length Wago (Ferrules Phoenix Contact Weidmuller (mm2) (AWG) (mm) product product product used) 0.25 24 0.34 22 0.5 20 0.75 18 1/1.25 18/17 10 AI 0,25-8 H0.25/12 12 AI 0,25-10 --- 216-301 8 10 AI 0,34-8 H0.34/12 10 12 AI 0,34-10 --- 8 10 AI 0,5-8 H0.5/14 216-201 10 12 AI 0,5-10 H0.5/16 216-241 216-202 --216-302 --- 8 10 AI 0,75-8 H0.75/14 10 12 AI 0,75-10 H0.75/16 216-242 8 10 AI 1-8 H1.0/14 216-203 10 12 AI 1-10 H1.0/16 216-243 8 10 AI 1,5-8 H1.5/14 216-204 10 12 AI 1,5-10 H1.5/16 216-244 CRIMPFOX6 CRIMPFOX6T-F CRIMPFOX10S PZ6 roto Variocrimp4 Recommended crimp tool Note: 1. Make sure that the outer diameter of the wire is smaller than the inner diameter of the insulating sleeve of the recommended ferrule. 2. Make sure that the ferrule processing dimensions conform to the following figure. Stranded wires, without ferrule Stranded wires, with ferrule and plastic collar Stranded wires with ferrule, without plastic collar Single wire Stripping length 0.5 to 1.5 mm2 8 mm 0.5 to 1.5 mm2 8 mm 0.5 to 1.5 mm2 8 mm 2 8 mm 0.5 to 1.5 mm * Tightening Torque 0.4 N * m * Electric wiring Use the electric wire of specified size as shown above. The length of the that is not covered is 8 mm. Screw terminal G3RV-SR 1.25/1.5 17/16 8 10 Applicable wire size Wired type G2RV-SR Applicable wire 8 mm Stripping length Operating latching lever (test switch) When operating the latching lever for G2RV-SR701/501 series, use a 2.5 mm width flat-blade screwdriver. 8 to 10 mm * Applicable flat-blade screwdriver 2.6 mm max. 3. If you use AWG24 to AWG22 (0.25 to 0.34 mm2) wires, UL certification will not apply. Flat-blade screwdriver with parallel cutting edge: shaft diameter 2.5 mm (3.0 mm max.) Parallel cutting edge flat-blade screwdriver Recommended Flat-blade Screwdriver Use a flat-blade screwdriver to connect and remove wires. Use the following flat-blade screwdriver. The following table shows manufacturers and models as of 2015/Dec. Side Front Shaft diameter 2.5 mm (3.0 mm max.) Wide flat-blade screwdriver Driver with a thick shaft cannot be used. * Always turn OFF the power supply before operating latching lever. 2.5 mm dia. * Return to its original state after using the latching lever. * Do not use the latching lever as a switch. 0.4 mm * Operation durability of the latching lever is 100 times or more. 2.5 mm Common Precautions 1.9 mm max. * Do not keep the latching lever ON for a long period of time (24 Model Manufacturer Wera SZS 0,4x2,5 SZF 0-0,4x2,5 * Phoenix Contact 0.4x2.5x75 302 Wiha AEF.2,5x75 Facom 210-719 Wago SDI 0.4x2.5x75 Weidmuller * OMRON's exclusive purchase model XW4Z-00B is available to order as SZF 0-0,4x2,5 (manufactured by Phoenix Contact). hours or more) in order to maintain the operation check function. Common Accessories ESD 0,40x2,5 23 G2RV-SR/G3RV-SR Method of operation of the latching lever (test switch) G2RV-SR Incorrect Example Countermeasure 1 Countermeasure 2 Recommended height of the duct is 1/2 or less of the height of the SSR Duct or other object blocking airflow Duct or other object blocking airflow Open protective cover Vertical Direction Duct or other object blocking airflow G3RV-SR Keep the protective cover open when using the latching lever. Move until the latching lever clicks to the ON position (ON state). After use latching lever, in order to prevent malfunction, return the switch to contact normal position (OFF state), and make sure the protective cover is firmly closed. Airflow Metal base SSR SSR SSR Do not enclose the SSR in a duct of the same height. It will interfere with the heat dissipation of SSR. Duct or other object blocking airflow Mounting surface Close protective cover Height of SSR Mounting surface Contact operating position (on-state) Mounting surface Contact normal position Duct or other object blocking airflow Use ducts that have a shallow depth, to provide a sufficient ventilation area. Duct or other object blocking airflow If the ducts cannot be made lower, place the SSR on a metal base so that it is not surrounded by the ducts. Be aware of airflow Duct or other object blocking airflow Exhaust (Axial fan) Using the latching lever Example: check the operation of the relay and the sequence circuit SSR Input ratings Smoothing capacitors are used in the internal circuits of AC/DCtype G2RV-SR devices. AC/DC-type G2RV-SR devices driven by the sensor may not operate normally due to the characteristics of the smoothing capacitor. When driving such devices by the sensor, use the DC specification settings. SSR SSR Inlet Common Precautions * If the air inlet or air outlet has a filter, clean the filter regularly to prevent it from clogging to ensure an efficient flow of air. * Since the G3RV uses electronic components, do not allow it to fall, vibrate, or apply shock that exceeds the criteria. Doing so may result in failure, malfunction, or deterioration of performance. * Tighten screw terminal for G3RV at torque 0.4 N * m. It may cause short-circuit failure or burning. * Please use the voltage and current suitable for the input and output terminal portion of G3RV. It may cause short-circuit failure or burning. * Do not place objects that may obstruct the proper ventilation for outside or inside the inlet or exhaust port, and in the outside vicinity. * A heat exchanger, if used, should be located in front of the G3RV to ensure the efficiency of the heat exchanger. * Please observe the ambient temperature of G3RV. The rated current of the G3RV is measured at an ambient temperature of 25C. * The G3RV uses a semiconductor in the output element. Mounting This causes the temperature inside the control panel to increase due to heating resulting from the flow of electrical current through Duct or other object blocking airflow the load. The G3RV reliability can be increased by adding a ventilation fan to the control panel to dispel this heat, thus lowering Common Accessories the ambient temperature of the G3RV. SSR 10 mm min. 60 mm min. (It suggests that life expectancy is doubled by each 10C reduction in ambient temperature.) EMI Vertical Direction 30 mm min. 80 mm min. * When five or more are installed, install with 10 mm space between each. 24 The G3RV is a Class A product (for industrial environments). When used in a residential environment, it may cause radio interference. In such case, the user may be required to take appropriate measures. G2RV-SR/G3RV-SR For G2RV-SR/G3VR-SR Common Accessories (order separately) Short Bars Appearance No. of poles Pitch Colors 2 Maximum energizing current PYDN-6.2-020@ 3 6.2 mm Minimum order (Quantity) Model * Red (R), Blue (S), Yellow (Y) 4 10 20 G2RV-SR Ordering Information PYDN-6.2-030@ PYDN-6.2-040@ 10 32 A PYDN-6.2-100@ PYDN-6.2-200@ Note: Use for wiring to the adjacent socket. * Replace the box (@) in the model number with the code for the covering color. @ color selection: R = red, S = blue, Y = yellow Label Appearance Minimum order (Sheet) (Pieces per sheet) Model G3RV-SR XW5Z-P2.5LB1 * 5 (1 sheet/72 pieces) XW5Z-P2.5LB2 * Available following June 2017 production. Separate Plate Appearance Model XW5Z-EP12 Appearance I/O classification Connection method Common process Applicable Models * PNP Push-In Model P2RVC-8-I-5-1 G2RV-SR500-AP For input NPN Screw G2RV-SR700-AP P2RVC-8-I-7-1 PNP G2RV-SR500 G2RV-SR501 G3RV-SR500 P2RVC-8-O-5-1 Push-In NPN For output Screw P2RVC-8-I-5 PNP PNP G2RV-SR700 G2RV-SR701 G3RV-SR700 P2RVC-8-O-5 Common Precautions PLC interface unit P2RVC-8-O-7-1 * Please make sure applicable models, P2RVC can not be used other combination than the above table. Appearance Type Model 1m PFP-100N 0.5 m PFP-50N 1 DIN Tracks End Plate * Minimum order (Quantity) PFP-M 10 Spacer PFP-S Common Accessories Parts for DIN Track Mounting * When mounting DIN Track, please use End Plate (PFP-M). Refer to your OMRON website for details on PFP-@. 25 G2RV-SR/G3RV-SR Applicable Cables G2RV-SR Name Appearance Cables with Loose Wires P2RV-A@C 8 I/O points Cables with Connectors (1:4) P2RV-4-@C G3RV-SR Common Precautions 1,000 P2RV-A100C 2,000 P2RV-A200C 3,000 P2RV-A300C 5,000 P2RV-A500C 1,000 P2RV-4-100C 2,000 P2RV-4-200C 3,000 P2RV-4-300C 5,000 P2RV-4-500C 1,000 P2RV-4-100IMC 2,000 P2RV-4-200IMC 3,000 P2RV-4-300IMC 5,000 P2RV-4-500IMC 1,000 P2RV-4-100IFC 2,000 P2RV-4-200IFC 3,000 P2RV-4-300IFC 5,000 P2RV-4-500IFC 32 output points L Cables with Connectors (1:4) P2RV-4-@IMC 300 32 input points L Common Accessories 26 End B L 70 Cables with Connectors (1:4) P2RV-4-@IFC 300 32 input points L 8 output Cables with Connectors points (1:1) P2RV-A@C-OMR GRT1 8 input points Cables with Connectors (1:1) P2RV-A@C-OMR NX 8 output points 8 input points 300 L Removable terminal block L Connecting Cables PLC interface unit end End A Device end Cable length L (mm) 500 P2RV-A050C-OMR GRT1 1,000 P2RV-A100C-OMR GRT1 500 P2RV-A050IC-OMR GRT1 1,000 P2RV-A100IC-OMR GRT1 500 P2RV-A050C-OMR NX 1,000 P2RV-A100C-OMR NX 500 P2RV-A050IC-OMR NX 1,000 P2RV-A100IC-OMR NX Applicable Connectors Various devices PLC I/O Units with MIL connectors (1:4) CJ1W-OD232/OD262, etc. PLC I/O Units with MIL connectors (1:4) CJ1W-ID232/ID262, etc. PLC I/O Units with Fujitsu connectors (1:4) CJ1W-ID231/ID261, etc. Slice I/O Units (1:1) For inputs: GRT1-ID8-1 For outputs: GRT1-OD8-1 PLC I/O Units with screw-less clamp terminal block (1:1) For inputs: NX-ID4442 For outputs: NX-OD4256 G2RV-SR/G3RV-SR Name Appearance 32 input points End B Device end PLC interface unit end 32 output points Schneider Electric PLC Connecting Cables P2RV-@C-SCH-@ L 300 16 output points L 300 32 input points Siemens PLC Connecting Cables P2RV-@C-SIM-@ L 300 16 input points 300 32 input points 32 output points L 300 P2RV-100C-SCH-A 2,000 P2RV-200C-SCH-A 3,000 P2RV-300C-SCH-A 5,000 P2RV-500C-SCH-A 500 P2RV-050C-SCH-B 1,000 P2RV-100C-SCH-B 2,000 P2RV-200C-SCH-B 3,000 P2RV-300C-SCH-B 5,000 P2RV-500C-SCH-B 500 P2RV-050C-SCH-C 1,000 P2RV-100C-SCH-C 2,000 P2RV-200C-SCH-C 3,000 P2RV-300C-SCH-C 5,000 P2RV-500C-SCH-C 500 P2RV-050C-SCH-D 1,000 P2RV-100C-SCH-D 2,000 P2RV-200C-SCH-D 3,000 P2RV-300C-SCH-D 5,000 P2RV-500C-SCH-D 500 P2RV-050C-SIM-A 1,000 P2RV-100C-SIM-A 2,000 P2RV-200C-SIM-A 3,000 P2RV-300C-SIM-A 5,000 P2RV-500C-SIM-A 500 P2RV-050C-SIM-B 1,000 P2RV-100C-SIM-B 2,000 P2RV-200C-SIM-B 3,000 P2RV-300C-SIM-B 5,000 P2RV-500C-SIM-B 500 P2RV-050C-SIM-C 1,000 P2RV-100C-SIM-C 2,000 P2RV-200C-SIM-C 3,000 P2RV-300C-SIM-C 5,000 P2RV-500C-SIM-C 500 P2RV-050C-SIM-D 1,000 P2RV-100C-SIM-D 2,000 P2RV-200C-SIM-D 3,000 P2RV-300C-SIM-D 5,000 P2RV-500C-SIM-D 500 P2RV-050C-SIM-E 1,000 P2RV-100C-SIM-E 2,000 P2RV-200C-SIM-E 3,000 P2RV-300C-SIM-E 5,000 P2RV-500C-SIM-E Schneider Electric PLCs with 32-point connectors (1:4) For inputs: 140 DDI 353 00 For outputs: 140 DDO 353 00 Schneider Electric PLCs with 16-point connectors (1:2) For inputs: BMX DDI 1602 For outputs: BMX DDO 1602 Siemens PLCs with 32-point connectors (1:4) For inputs: 6ES7 321-1BL00-0AA0 For outputs: 6ES7 322-1BL00-0AA0 Siemens PLCs with 16-point connectors (1:2) For inputs: 6ES7 321-1BH02-0AA0 Siemens PLCs with 32-point connectors (1:4) For inputs: 6ES7 421-1BL-0AA0 For outputs: 6ES7 422-1BL-0AA0 Common Accessories L P2RV-050C-SCH-A Common Precautions 32 output points 500 1,000 Applicable Connectors G3RV-SR 16 input points Connecting Cables G2RV-SR End A Cable length L (mm) 27 G2RV-SR/G3RV-SR PLC interface unit Ratings / characteristices G2RV-SR Rated voltage 30 VAC/DC Rated current 0.5 A/poles, 2 A/unit Ambient operating temperature -40 to 55C Vibration resistance Shock resistance Destruction 10 to 55 to 10 Hz, single amplitude 0.75 mm (double amplitude 1.5 mm) Malfunction 10 to 55 to 10 Hz, single amplitude 0.75 mm (double amplitude 1.5 mm) Destruction 300 m/s2 Malfunction 100 m/s2 Electrical schematic Input P2RVC-8-I-@-1 (PNP) 1....................8 14 P2RVC-8-I-5 (NPN) 1....................8 14 G3RV-SR 11 11 1 3 5 7 9 2 4 6 8 10 Common Precautions Output P2RVC-8-O-@-1 (PNP) Common Accessories 28 1....................8 1 3 5 7 9 2 4 6 8 10 P2RVC-8-O-5 (NPN) 1....................8 A2 A2 A1 1 3 5 7 9 2 4 6 8 10 A1 1 3 5 7 9 2 4 6 8 10 G2RV-SR/G3RV-SR Dimensions (unit: mm) PLC interface unit G2RV-SR Push-IN P2RVC-8-I-5(-1) P2RVC-8-O-5(-1) 49.60 67.16 7x6.20 29 Screw P2RVC-8-I-7-1 P2RVC-8-O-7-1 67.16 12.68 7x6.20 29 Common Precautions 49.60 G3RV-SR 12.68 Common Accessories 29 G2RV-SR/G3RV-SR (Except for PLC interface unit) Common Accessories (order separately) G2RV-SR Dimensions (unit: mm) Short Bars PYDN-6.2-@@ (6.2 mm) 2 L Pitch No. of poles 1.20 6.2 mm 9 14 6.20 L (Length) 2 12.4 3 18.6 4 24.8 10 62 20 124 Colors Model * Maximum carry current PYDN-6.2-020@ Red (R) Blue (S) Yellow (Y) PYDN-6.2-030@ PYDN-6.2-040@ 32 A PYDN-6.2-100@ PYDN-6.2-200@ Note: Use the Short Bars for crossover wiring within one Socket or between Sockets. * Replace the box (@) in the model number with the code for the covering color. Separate Plate XW5Z-EP12 G3RV-SR 12 56 63 Common Precautions Parts for DIN Track Mounting Refer to your OMRON website for details on the PFP-@. Safety Precautions Precautions for Correct Use When mounting a short bar Mounting a separate plate * Intermediate pins can be bent by a tool or by hand and cut off for use. * Use a flat-blade screwdriver to tighten the center top screw and secure the plate. Loosen the screw to remove the plate from the DIN rail. M4 Screw Common Accessories Bend Cut off * The short bar can be cut to as many poles as needed. Insert the tool from the plastic part side, and cut along the groove in the plastic part between the terminals. When cutting, take care not to break or deform the terminals. However, because the metal on the cut surface will be exposed, insulation countermeasures between adjacent products must be ensured. Such countermeasures include widening the intervals between products or using XW5Z-EP12 separate plates (order separately). Cut 30 Terms and Conditions Agreement Read and understand this catalog. Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Warranties. (a) Exclusive Warranty. Omron's exclusive warranty is that the Products will be free from defects in materials and workmanship for a period of twelve months from the date of sale by Omron (or such other period expressed in writing by Omron). Omron disclaims all other warranties, express or implied. (b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUT NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS. BUYER ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the Products or otherwise of any intellectual property right. (c) Buyer Remedy. Omron's sole obligation hereunder shall be, at Omron's election, to (i) replace (in the form originally shipped with Buyer responsible for labor charges for removal or replacement thereof) the non-complying Product, (ii) repair the non-complying Product, or (iii) repay or credit Buyer an amount equal to the purchase price of the non-complying Product; provided that in no event shall Omron be responsible for warranty, repair, indemnity or any other claims or expenses regarding the Products unless Omron's analysis confirms that the Products were properly handled, stored, installed and maintained and not subject to contamination, abuse, misuse or inappropriate modification. Return of any Products by Buyer must be approved in writing by Omron before shipment. Omron Companies shall not be liable for the suitability or unsuitability or the results from the use of Products in combination with any electrical or electronic components, circuits, system assemblies or any other materials or substances or environments. Any advice, recommendations or information given orally or in writing, are not to be construed as an amendment or addition to the above warranty. See http://www.omron.com/global/ or contact your Omron representative for published information. Limitation on Liability; Etc. OMRON COMPANIES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY. Further, in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted. Suitability of Use. Omron Companies shall not be responsible for conformity with any standards, codes or regulations which apply to the combination of the Product in the Buyer's application or use of the Product. At Buyer's request, Omron will provide applicable third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself is not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine, system, or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product with respect to Buyer's application, product or system. Buyer shall take application responsibility in all cases. NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. Programmable Products. Omron Companies shall not be responsible for the user's programming of a programmable Product, or any consequence thereof. Performance Data. Data presented in Omron Company websites, catalogs and other materials is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of Omron's test conditions, and the user must correlate it to actual application requirements. Actual performance is subject to the Omron's Warranty and Limitations of Liability. Change in Specifications. Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change part numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers may be assigned to fix or establish key specifications for your application. Please consult with your Omron's representative at any time to confirm actual specifications of purchased Product. Errors and Omissions. Information presented by Omron Companies has been checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical or proofreading errors or omissions. OMRON Corporation Industrial Automation Company Authorized Distributor: Kyoto, JAPAN Contact: www.ia.omron.com Regional Headquarters OMRON EUROPE B.V. Wegalaan 67-69, 2132 JD Hoofddorp The Netherlands Tel: (31)2356-81-300/Fax: (31)2356-81-388 OMRON ELECTRONICS LLC 2895 Greenspoint Parkway, Suite 200 Hoffman Estates, IL 60169 U.S.A. Tel: (1) 847-843-7900/Fax: (1) 847-843-7787 OMRON ASIA PACIFIC PTE. LTD. No. 438A Alexandra Road # 05-05/08 (Lobby 2), Alexandra Technopark, Singapore 119967 Tel: (65) 6835-3011/Fax: (65) 6835-2711 OMRON (CHINA) CO., LTD. Room 2211, Bank of China Tower, 200 Yin Cheng Zhong Road, PuDong New Area, Shanghai, 200120, China Tel: (86) 21-5037-2222/Fax: (86) 21-5037-2200 (c) OMRON Corporation 2016-2017 All Rights Reserved. In the interest of product improvement, specifications are subject to change without notice. CSM_6_5_0618 Cat. No. J214-E1-02 0617(0316)