USE ULTRA37000TM FOR ALL NEW DESIGNS CY7C344B 32-Macrocell MAX(R) EPLD Features densest EPLD of this size. Eight dedicated inputs and 16 bidirectional I/O pins communicate to one logic array block. In the CY7C344 LAB there are 32 macrocells and 64 expander product terms. When an I/O macrocell is used as an input, two expanders are used to create an input path. Even if all of the I/O pins are driven by macrocell registers, there are still 16 "buried" registers available. All inputs, macrocells, and I/O pins are interconnected within the LAB. * High-performance, high-density replacement for TTL, 74HC, and custom logic * 32 macrocells, 64 expander product terms in one LAB * 8 dedicated inputs, 16 I/O pins * 0.8-micron double-metal CMOS EPROM technology The speed and density of the CY7C344 makes it a natural for all types of applications. With just this one device, the designer can implement complex state machines, registered logic, and combinatorial "glue" logic, without using multiple chips. This architectural flexibility allows the CY7C344 to replace multichip TTL solutions, whether they are synchronous, asynchronous, combinatorial, or all three. * 28-pin, 300-mil DIP, cerDIP or 28-pin HLCC, PLCC package Functional Description Available in a 28-pin, 300-mil DIP or windowed J-leaded ceramic chip carrier (HLCC), the CY7C344 represents the Logic Block Diagram [1] Pin Configurations HLCC Top View INPUT 15(23) INPUT INPUT/CLK 2(9) 27(6) INPUT INPUT 13(20) 28(7) INPUT INPUT 14(21) MACROCELL 1 MACROCELL 8 MACROCELL 10 MACROCELL 12 MACROCELL 14 MACROCELL 20 MACROCELL 22 I/O I/O I/O VCC GND I/O I/O 3(10) I/O 4(11) I/O 5(12) L O I MACROCELL 7 O I/O 6(13) B A MACROCELL 11 MACROCELL 3 G L MACROCELL 16 MACROCELL 18 I/O MACROCELL 5 MACROCELL 4 MACROCELL 6 4 3 2 1 28 27 26 I/O 9(16) C O I/O 10(17) I/O 11(18) N T I/O 12(19) I/O 17(24) R I/O 18(25) O L I/O 19(26) I/O 20(27) MACROCELL 9 MACROCELL 13 MACROCELL 15 B MACROCELL 17 U S MACROCELL 19 MACROCELL 21 MACROCELL 24 MACROCELL 23 MACROCELL 26 MACROCELL 25 I/O 23(2) MACROCELL 28 MACROCELL 27 I/O 24(3) MACROCELL 30 MACROCELL 29 I/O 25(4) MACROCELL 32 MACROCELL 31 I/O 26(5) 64 EXPANDER PRODUCT TERM ARRAY Cypress Semiconductor Corporation Document #: 38-03006 Rev. *A * 32 3901 North First Street * I/O INPUT INPUT INPUT INPUT/CLK I/O I/O 5 6 7 8 9 10 11 12 13 14 1516 1718 I/O I/O MACROCELL 2 1(8) 25 24 23 22 21 20 19 I/O I/O INPUT INPUT INPUT INPUT I/O I/O INPUT VCC GND I/O I/O 15(22) CerDIP Top View INPUT INPUT/CLK I/O I/O I/O I/O VCC GND I/O I/O I/O I/O INPUT INPUT San Jose, CA 95134 1 2 3 4 5 6 7 8 9 10 11 12 13 14 28 27 26 25 24 23 22 21 20 19 18 17 16 15 INPUT INPUT I/O I/O I/O I/O VCC GND I/O I/O I/O I/O INPUT INPUT * 408-943-2600 Revised April 19, 2004 USE ULTRA37000TM FOR ALL NEW DESIGNS CY7C344B Selection Guide Maximum Access Time Maximum Operating Current Commercial 7C344-15 7C344-20 7C344-25 Unit 15 20 25 ns 200 200 200 mA 220 220 Military Maximum Standby Current Industrial 220 220 220 Commercial 150 150 150 170 170 170 170 Military Industrial 170 mA Note: 1. Numbers in () refer to J-leaded packages. Document #: 38-03006 Rev. *A Page 2 of 16 USE ULTRA37000TM FOR ALL NEW DESIGNS CY7C344B Maximum Ratings Static Discharge Voltage (per MIL-STD-883, Method 3015) ............................. >2001V (Above which the useful life may be impaired. For user guidelines, not tested.) DC Output Current, per Pin ......................-25 mA to +25 mA Storage Temperature .................................-65C to +150C Ambient Temperature with Power Applied...................................................0C to +70C Maximum Junction Temperature (Under Bias)............. 150C DC Input Voltage[2] .........................................-3.0V to +7.0V DC Program Voltage................................................... +13.0V Operating Range Supply Voltage to Ground Potential ............... -2.0V to +7.0V Ambient Temperature Range Maximum Power Dissipation...................................1500 mW Commercial DC VCC or GND Current ............................................500 mA Industrial Military VCC 0C to +70C 5V 5% -40C to +85C 5V 10% -55C to +125C (Case) 5V 10% [3] Electrical Characteristics Over the Operating Range Parameter Description Test Conditions Min. Max. Unit VOH Output HIGH Voltage VCC = Min., IOH = -4.0 mA 2.4 VOL Output LOW Voltage VCC = Min., IOL = 8 mA 0.45 V VIH Input HIGH Level 2.2 VCC+0.3 V VIL Input LOW Level -0.3 0.8 V IIX Input Current GND VIN VCC -10 +10 A IOZ Output Leakage Current VO = VCC or GND -40 +40 A -30 -90 mA 0.5V[4, 5] V IOS Output Short Circuit Current VCC = Max., VOUT = ICC1 Power Supply Current (Standby) VI = VCC or GND (No Load) Commercial 150 mA Military/Industrial 170 mA ICC2 Power Supply Current VI = VCC or GND (No Load) f = 1.0 MHz[4,6] Commercial 200 mA Military/Industrial 220 mA tR Recommended Input Rise Time 100 ns tF Recommended Input Fall Time 100 ns Capacitance Max. Unit CIN Parameter Input Capacitance Description VIN = 2V, f = 1.0 MHz Test Conditions 10 pF COUT Output Capacitance VOUT = 2.0V, f = 1.0 MHz 10 pF AC Test Loads and Waveforms[7] R1 464 5V R1 464 5V OUTPUT ALL INPUT PULSES OUTPUT R2 250 50 pF INCLUDING JIG AND SCOPE Equivalent to: 3.0V R2 250 5 pF GND 10% 6 ns tR (a) 90% 10% 90% tf 6 ns tF (b) THEVENIN EQUIVALENT (commercial/military) 163 OUTPUT 1.75V Notes: 2. Minimum DC input is -0.3V. During transitions, the inputs may undershoot to -2.0V for periods less than 20 ns. 3. Typical values are for TA = 25C and VCC = 5V. 4. Guaranteed by design but not 100% tested. 5. Not more than one output should be tested at a time. Duration of the short circuit should not be more than one second. VOUT = 0.5V has been chosen to avoid test problems caused by tester ground degradation. 6. Measured with device programmed as a 16-bit counter. 7. Part (a) in AC Test Load and Waveforms is used for all parameters except tER and tXZ, which is used for part (b) in AC Test Load and Waveforms. All external timing parameters are measured referenced to external pins of the device. Document #: 38-03006 Rev. *A Page 3 of 16 USE ULTRA37000TM FOR ALL NEW DESIGNS Timing Delays Timing delays within the CY7C344 may be easily determined using Warp(R), Warp ProfessionalTM, or Warp EnterpriseTM software. The CY7C344 has fixed internal delays, allowing the user to determine the worst case timing delays for any design. Design Recommendations Operation of the devices described herein with conditions above those listed under "Maximum Ratings" may cause permanent damage to the device. This is a stress rating only and functional operation of the device at these or any other conditions above those indicated in the operational sections of this data sheet is not implied. Exposure to absolute maximum ratings conditions for extended periods of time may affect device reliability. The CY7C344 contains circuitry to protect device pins from high-static voltages or electric fields; however, normal precautions should be taken to avoid applying any voltage higher than maximum rated voltages. For proper operation, input and output pins must be constrained to the range GND (VIN or VOUT) VCC. Unused inputs must always be tied to an appropriate logic level (either VCC or GND). Each set of VCC and GND pins must be connected together directly at the device. Power supply decoupling capacitors of at least 0.2 F must be connected between VCC and GND. For the most effective decoupling, each VCC pin should be separately decoupled. Timing Considerations Unless otherwise stated, propagation delays do not include expanders. When using expanders, add the maximum expander delay tEXP to the overall delay. When calculating synchronous frequencies, use tS1 if all inputs are on the input pins. tS2 should be used if data is applied at an I/O pin. If tS2 is greater than tCO1, 1/tS2 becomes the limiting frequency in the data-path mode unless 1/(tWH + tWL) is less than 1/tS2. When expander logic is used in the data path, add the appropriate maximum expander delay, tEXP to tS1. Determine which of 1/(tWH + tWL), 1/tCO1, or 1/(tEXP + tS1) is the lowest frequency. The lowest of these frequencies is the maximum data-path frequency for the synchronous configuration. When calculating external asynchronous frequencies, use tAS1 if all inputs are on dedicated input pins. If any data is applied to an I/O pin, tAS2 must be used as the required set-up time. If (tAS2 + tAH) is greater than tACO1, 1/(tAS2 + tAH) becomes the limiting frequency in the data-path mode unless 1/(tAWH + tAWL) is less than 1/(tAS2 + tAH). When expander logic is used in the data path, add the appropriate maximum expander delay, tEXP to tAS1. Determine which of 1/(tAWH + tAWL), 1/tACO1, or 1/(tEXP + tAS1) is the lowest frequency. The lowest of these frequencies is the maximum data-path frequency for the asynchronous configuration. The parameter tOH indicates the system compatibility of this device when driving other synchronous logic with positive input hold times, which is controlled by the same synchronous clock. If tOH is greater than the minimum required input hold time of the subsequent synchronous logic, then the devices are guaranteed to function properly with a common synchronous clock under worst-case environmental and supply voltage conditions. The parameter tAOH indicates the system compatibility of this device when driving subsequent registered logic with a positive hold time and using the same clock as the CY7C344. In general, if tAOH is greater than the minimum required input hold time of the subsequent logic (synchronous or asynchronous), then the devices are guaranteed to function properly under worst-case environmental and supply voltage conditions, provided the clock signal source is the same. This also applies if expander logic is used in the clock signal path of the driving device, but not for the driven device. This is due to the expander logic in the second device's clock signal path adding an additional delay (tEXP), causing the output data from the preceding device to change prior to the arrival of the clock signal at the following device's register. EXPANDER DELAY t EXP REGISTER LOGIC ARRAY CONTROLDELAY tCLR tLAC tPRE INPUT INPUT DELAY tIN CY7C344B LOGIC ARRAY tRSU DELAY tRH tLAD OUTPUT DELAY OUTPUT tOD tXZ tZX tRD tCOMB tLATCH SYSTEM CLOCK DELAYtICS I/O I/O I/O DELAY tIO CLOCK DELAY tIC FEEDBACK DELAY tFD C344-7 Figure 1. CY7C344 Timing Model Document #: 38-03006 Rev. *A Page 4 of 16 USE ULTRA37000TM FOR ALL NEW DESIGNS CY7C344B External Synchronous Switching Characteristics Over Operating Range [7] 7C344-15 Parameter tPD1 tPD2 Description Min. [9] I/O Input to Combinatorial Output Delay Min. Max. 7C344-25 Max. Unit 15 20 25 ns Mil 15 20 25 Com'l/Ind 15 20 25 Mil 15 20 25 Dedicated Input to Combinatorial Output Delay[8] Com'l/Ind Max. 7C344-20 Min. tPD3 Dedicated Input to Combinatorial Output Delay with Expander Delay[10] Com'l/Ind 30 30 40 Mil 30 30 40 tPD4 I/O Input to Combinatorial Output Delay with Expander Delay[4, 11] Com'l/Ind 30 30 40 Mil 30 30 40 tEA Input to Output Enable Delay[4] Com'l/Ind 20 20 25 Mil 20 20 25 tER [4] Com'l/Ind 20 20 25 Mil 20 20 25 Com'l/Ind 10 12 15 Input to Output Disable Delay tCO1 Synchronous Clock Input to Output Delay Mil 10 12 15 tCO2 Synchronous Clock to Local Feedback to Combinatorial Output[4, 12] Com'l/Ind 20 22 29 tS Dedicated Input or Feedback Set-Up Time to Synchronous Clock Input Com'l/Ind 10 12 15 Mil 10 12 15 tH Input Hold Time from Synchronous Clock Input[7] Com'l/Ind 0 0 0 Mil 0 0 0 Com'l/Ind 6 7 8 Mil 6 7 8 Com'l/Ind 6 7 8 tWH Synchronous Clock Input HIGH Time[4] tWL Synchronous Clock Input LOW Time[4] tRW Asynchronous Clear Width[4] tRR Asynchronous Clear Recovery Time[4] Mil 20 22 6 7 8 Com'l/Ind 20 20 25 Mil 20 20 25 Com'l/Ind 20 20 25 Mil 20 20 25 tRO Asynchronous Clear to Registered Output Delay[4] Com'l/Ind tPW Asynchronous Preset Width[4] Com'l /Ind 20 20 25 Mil 20 20 25 tPR Asynchronous Preset Recovery Time[4] Com'l /Ind 20 20 25 Mil 20 20 25 Mil 20 15 ns ns ns ns ns ns 29 Mil 15 ns ns ns ns ns ns ns 25 20 ns 25 ns ns Notes: 8. This parameter is the delay from an input signal applied to a dedicated input pin to a combinatorial output on any output pin. This delay assumes no expander terms are used to form the logic function. 9. This parameter is the delay associated with an input signal applied to an I/O macrocell pin to any output. This delay assumes no expander terms are used to form the logic function. 10. This parameter is the delay associated with an input signal applied to a dedicated input pin to combinatorial output on any output pin. This delay assumes expander terms are used to form the logic function and includes the worst-case expander logic delay for one pass through the expander logic. This parameter is tested periodically by sampling production material. 11. This parameter is the delay associated with an input signal applied to an I/O macrocell pin to any output pin. This delay assumes expander terms are used to form the logic function and includes the worst-case expander logic delay for one pass through the expander logic. This parameter is tested periodically by sampling production material. 12. This specification is a measure of the delay from synchronous register clock input to internal feedback of the register output signal to a combinatorial output for which the registered output signal is used as an input. This parameter assumes no expanders are used in the logic of the combinatorial output and the register is synchronously clocked. This parameter is tested periodically by sampling production material. Document #: 38-03006 Rev. *A Page 5 of 16 USE ULTRA37000TM FOR ALL NEW DESIGNS CY7C344B External Synchronous Switching Characteristics Over Operating Range (continued)[7] 7C344-15 Parameter Description Min. tPO Asynchronous Preset to Registered Output Delay[4] tCF Synchronous Clock to Local Feedback Input[4, 13] Com'l /Ind tP External Synchronous Clock Period (1/fMAX3)[4] fMAX1 External Maximum Frequency(1/(tCO1 + tS)) 7C344-20 Min. Max. 7C344-25 Min. Unit ns 15 20 25 Mil 15 20 25 4 4 7 4 4 ns 7 Com'l/Ind 13 14 16 Mil 13 14 16 Com'l/Ind 50.0 41.6 33.3 Mil 50.0 41.6 33.3 fMAX2 Maximum Frequency with Internal Only Feedback (1/(tCF + tS))[4, 15] Com'l/Ind 71.4 62.5 45.4 Mil 71.4 62.5 45.4 fMAX3 Data Path Maximum Frequency, least of 1/(tWL + tWH), 1/(tS + tH), or (1/tCO1)[4, 16] Com'l/Ind 83.3 71.4 62.5 Mil 83.3 71.4 62.5 fMAX4 Maximum Register Toggle Frequency 1/(tWL + tWH)[4, 17] Com'l/Ind 83.3 71.4 62.5 Mil 83.3 71.4 62.5 Output Data Stable Time from Synchronous Clock Input[4, 18] Com'l/Ind 3 3 3 Mil 3 3 3 tOH Max. Com'l /Ind Mil [4, 14] Max. ns MHz MHz MHz MHz ns Notes: 13. This specification is a measure of the delay associated with the internal register feedback path. This delay plus the register set-up time, tS, is the minimum internal period for an internal state machine configuration. This parameter is tested periodically by sampling production material. 14. This specification indicates the guaranteed maximum frequency at which a state machine configuration with external only feedback can operate. 15. This specification indicates the guaranteed maximum frequency at which a state machine with internal-only feedback can operate. If register output states must also control external points, this frequency can still be observed as long as it is less than 1/tCO1. This specification assumes no expander logic is used. This parameter is tested periodically by sampling production material. 16. This frequency indicates the maximum frequency at which the device may operate in data-path mode (dedicated input pin to output pin). This assumes that no expander logic is used. 17. This specification indicates the guaranteed maximum frequency in synchronous mode, at which an individual output or buried register can be cycled by a clock signal applied to either a dedicated input pin or an I/O pin. 18. This parameter indicates the minimum time after a synchronous register clock input that the previous register output data is maintained on the output pin. Document #: 38-03006 Rev. *A Page 6 of 16 USE ULTRA37000TM FOR ALL NEW DESIGNS CY7C344B External Asynchronous Switching Characteristics Over Operating Range[7] 7C344-15 Parameter tACO1 Description Asynchronous Clock Input to Output Delay 7C344-20 7C344-25 Min. Max. Min. Max. Min. Max. Com'l/Ind 15 20 25 Mil 15 20 25 30 30 37 tACO2 Asynchronous Clock Input to Local Feedback to Combinatorial Output[19] Com'l/Ind tAS Dedicated Input or Feedback Set-Up Time to Asynchronous Clock Input Com'l/Ind 7 9 12 Mil 7 9 12 tAH Input Hold Time from Asynchronous Clock Input Com'l/Ind 7 9 12 Mil 7 9 12 tAWH Asynchronous Clock Input HIGH Time[4, 20] Com'l/Ind 6 7 9 Mil 6 7 9 Com'l/Ind 7 9 11 Mil 7 Time[4] tAWL Asynchronous Clock Input LOW tACF Asynchronous Clock to Local Feedback Input[4, 21] (1/fMAX4)[4] Mil 30 30 9 ns ns ns 11 18 21 Mil 18 18 21 Com'l/Ind fMAXA1 External Maximum Frequency in Asynchronous Mode 1/(tACO1 + tAS)[4, 22] 16 20 Com'l/Ind 13 16 20 45.4 34.4 27 Mil 45.4 34.4 27 fMAXA2 Maximum Internal Asynchronous Frequency 1/(tACF + tAS) or 1/(tAWH + tAWL)[4, 23] Com'l/Ind 40 37 30.3 fMAXA3 Data Path Maximum Frequency in Asynchronous Mode[4, 24] Com'l/Ind 40 37 30.3 66.6 50 40 Mil 66.6 50 40 fMAXA4 Maximum Asynchronous Register Toggle Frequency 1/(tAWH + tAWL)[4, 25] Com'l/Ind 76.9 62.5 50 tAOH Output Data Stable Time from Asynchronous Clock Com'l/Ind Input[4, 26] Mil Mil 76.9 62.5 50 15 15 15 15 15 15 Mil Mil 13 ns ns 18 External Asynchronous Clock Period ns 37 Com'l/Ind tAP Unit ns ns MHz MHz MHz MHz ns Notes: 19. This specification is a measure of the delay from an asynchronous register clock input to internal feedback of the registered output signal to a combinatorial output for which the registered output signal is used as an input. Assumes no expanders are used in logic of combinatorial output or the asynchronous clock input. This parameter is tested periodically by sampling production material. 20. This parameter is measured with a positive-edge-triggered clock at the register. For negative edge triggering, the tAWH and tAWL parameters must be swapped. If a given input is used to clock multiple registers with both positive and negative polarity, tAWH should be used for both tAWH and tAWL. 21. This specification is a measure of the delay associated with the internal register feedback path for an asynchronously clocked register. This delay plus the asynchronous register set-up time, tAS, is the minimum internal period for an asynchronously clocked state machine configuration. This delay assumes no expander logic in the asynchronous clock path. This parameter is tested periodically by sampling production material. 22. This parameter indicates the guaranteed maximum frequency at which an asynchronously clocked state machine configuration with external feedback can operate. It is assumed that no expander logic is employed in the clock signal path or data path. 23. This specification indicates the guaranteed maximum frequency at which an asynchronously clocked state machine with internal-only feedback can operate. If register output states must also control external points, this frequency can still be observed as long as this frequency is less than 1/tACO1. This specification assumes no expander logic is utilized. This parameter is tested periodically by sampling production material. 24. This specification indicates the guaranteed maximum frequency at which an individual output or buried register can be cycled in asynchronously clocked mode. This frequency is least of 1/(tAWH + tAWL), 1/(tAS + tAH), or 1/tACO1. It also indicates the maximum frequency at which the device may operate in the asynchronously clocked data-path mode. Assumes no expander logic is used. 25. This specification indicates the guaranteed maximum frequency at which an individual output or buried register can be cycled in asynchronously clocked mode by a clock signal applied to an external dedicated input or an I/O pin. 26. This parameter indicates the minimum time that the previous register output data is maintained on the output pin after an asynchronous register clock input to an external dedicated input or I/O pin. Document #: 38-03006 Rev. *A Page 7 of 16 USE ULTRA37000TM FOR ALL NEW DESIGNS CY7C344B Typical Internal Switching Characteristics Over Operating Range[7] 7C344-15 Parameter tIN Description Dedicated Input Pad and Buffer Delay tIO I/O Input Pad and Buffer Delay tEXP Expander Array Delay tLAD Logic Array Data Delay tLAC Logic Array Control Delay tOD tZX tXZ Output Buffer and Pad Delay Output Buffer Enable Delay[27] Output Buffer Disable Delay Min. Max. 7C344-20 Min. Max. 7C344-25 Min. Max. Unit ns Com'l/Ind 4 5 7 Mil 4 5 7 Com'l/Ind 4 5 7 Mil 4 5 7 Com'l/Ind 8 10 15 Mil 8 10 15 Com'l/Ind 7 9 10 Mil 7 9 10 Com'l/Ind 5 7 7 Mil 5 7 7 Com'l/Ind 4 5 5 Mil 4 5 5 Com'l/Ind 7 8 11 Mil 7 8 11 Com'l/Ind 7 8 11 Mil 7 8 11 tRSU Register Set-Up Time Relative to Clock Signal at Register Com'l/Ind 5 5 Mil 5 5 8 tRH Register Hold Time Relative to Clock Signal at Register Com'l/Ind 7 9 12 Mil 7 tLATCH Flow-Through Latch Delay Com'l/Ind 1 1 3 Mil 1 1 3 tRD Register Delay Com'l/Ind 1 1 1 Mil 1 1 1 Com'l/Ind 1 1 3 Mil 1 1 3 tCOMB tCH Transparent Mode Delay[28] Clock HIGH Time tCL Clock LOW Time tIC Asynchronous Clock Logic Delay tICS Synchronous Clock Delay tFD Feedback Delay tPRE Asynchronous Register Preset Time 8 9 ns ns ns ns ns ns ns ns ns 12 Com'l/Ind 6 7 8 Mil 6 7 8 Com'l/Ind 6 7 8 Mil 6 7 ns ns ns ns ns 8 Com'l/Ind 7 8 10 Mil 7 8 10 Com'l/Ind 1 2 3 Mil 1 2 3 Com'l/Ind 1 1 1 Mil 1 1 1 Com'l/Ind 5 6 9 Mil 5 6 9 ns ns ns ns Notes: 27. Sample tested only for an output change of 500 mV. 28. This specification guarantees the maximum combinatorial delay associated with the macrocell register bypass when the macrocell is configured for combinatorial operation. Document #: 38-03006 Rev. *A Page 8 of 16 USE ULTRA37000TM FOR ALL NEW DESIGNS CY7C344B Typical Internal Switching Characteristics Over Operating Range[7] (continued) 7C344-15 Parameter Description Min. tCLR Asynchronous Register Clear Time Com'l/Ind tPCW Asynchronous Preset and Clear Pulse Width Max. Min. 5 Mil tPCR 7C344-20 Max. 7C344-25 Min. 6 5 6 5 5 7 Mil 5 5 7 5 5 7 5 5 7 Mil Unit 9 ns 9 Com'l/Ind Asynchronous Preset and Clear Recovery Time Com'l/Ind Max. ns ns Switching Waveforms External Combinatorial DEDICATED INPUT/ I/O INPUT tPD1/tPD2 COMBINATORIAL OUTPUT tER COMBINATORIAL OR REGISTERED OUTPUT HIGH-IMPEDANCE THREE-STATE tEA HIGH-IMPEDANCE THREE-STATE VALID OUTPUT External Synchronous DEDICATED INPUTS OR REGISTERED FEEDBACK tS tH tWH tWL SYNCHRONOUS CLOCK tCO1 ASYNCHRONOUS CLEAR/PRESET tRW/tPW tRR/tPR tOH tRO/tPO REGISTERED OUTPUTS tCO2 COMBINATORIAL OUTPUT FROM REGISTERED FEEDBACK [12] Document #: 38-03006 Rev. *A Page 9 of 16 USE ULTRA37000TM FOR ALL NEW DESIGNS CY7C344B Switching Waveforms (continued) External Asynchronous DEDICATED INPUTS OR REGISTERED FEEDBACK tAH tAS ASYNCHRONOUS CLOCK INPUT ASYNCHRONOUS CLEAR/PRESET tACO1 tAWH tRW/tPW tAWL tRR/tPR tAOH tRO/tPO ASYNCHRONOUS REGISTERED OUTPUTS tACO2 COMBINATORIAL OUTPUT FROM ASYNCH. REGISTERED FEEDBACK [19] Internal Combinatorial tIN INPUT PIN tIO tPIA I/O PIN tEXP EXPANDER ARRAY DELAY tLAC, tLAD LOGIC ARRAY INPUT LOGIC ARRAY OUTPUT Document #: 38-03006 Rev. *A Page 10 of 16 USE ULTRA37000TM FOR ALL NEW DESIGNS CY7C344B Switching Waveforms (continued) Internal Asynchronous tAWH tIOtR tAWL tF CLOCK PIN tIN CLOCK INTO LOGIC ARRAY tIC CLOCK FROM LOGIC ARRAY tRSU tRH DATA FROM LOGIC ARRAY tRD,tLATCH tFD tCLR,tPRE tFD REGISTER OUTPUT TO LOCAL LAB LOGIC ARRAY tPIA REGISTER OUTPUT TO ANOTHER LAB Internal Synchronous (Input Path) tCH tCL SYSTEM CLOCK PIN tIN tICS tRSU tRH SYSTEM CLOCK AT REGISTER DATA FROM LOGIC ARRAY Internal Synchronous (Output Path) CLOCK FROM LOGIC ARRAY tRD tOD DATA FROM LOGIC ARRAY tXZ OUTPUT PIN Document #: 38-03006 Rev. *A tZX HIGH Z Page 11 of 16 USE ULTRA37000TM FOR ALL NEW DESIGNS CY7C344B Ordering Information Speed (ns) 15 20 25 Ordering Code CY7C344-15HC/HI Package Name H64 28-Lead Windowed Leaded Chip Carrier CY7C344-15JC/JI J64 28-Lead Plastic Leaded Chip Carrier CY7C344-15PC/PI P21 28-Lead (300-Mil) Molded DIP CY7C344-15WC/WI W22 28-Lead Windowed CerDIP CY7C344-20HC/HI H64 28-Lead Windowed Leaded Chip Carrier CY7C344-20JC/JI J64 28-Lead Plastic Leaded Chip Carrier CY7C344-20PC/PI P21 28-Lead (300-Mil) Molded DIP CY7C344-20WC/WI W22 28-Lead Windowed CerDIP CY7C344-20HMB H64 28-Lead Windowed Leaded Chip Carrier CY7C344-20WMB W22 28-Lead Windowed CerDIP CY7C344-25HC/HI H64 28-Lead Windowed Leaded Chip Carrier CY7C344-25JC/JI J64 28-Lead Plastic Leaded Chip Carrier CY7C344-25PC/PI P21 28-Lead (300-Mil) Molded DIP CY7C344-25WC/WI W22 28-Lead Windowed CerDIP CY7C344-25HMB H64 28-Lead Windowed Leaded Chip Carrier CY7C344-25WMB W22 28-Lead Windowed CerDIP MILITARY SPECIFICATIONS Group A Subgroup Testing Commercial/Industrial Commercial/Industrial Military Commercial/Industrial Military Switching Characteristics Parameter DC Characteristics Parameter Operating Range Package Type tPD1 7, 8, 9, 10, 11 tPD2 7, 8, 9, 10, 11 tPD3 7, 8, 9, 10, 11 VOH 1, 2, 3 tCO1 7, 8, 9, 10, 11 VOL 1, 2, 3 tS 7, 8, 9, 10, 11 VIH 1, 2, 3 tH 7, 8, 9, 10, 11 VIL 1, 2, 3 tACO1 7, 8, 9, 10, 11 IIX 1, 2, 3 tACO1 7, 8, 9, 10, 11 IOZ 1, 2, 3 tAS 7, 8, 9, 10, 11 ICC1 1, 2, 3 tAH 7, 8, 9, 10, 11 Document #: 38-03006 Rev. *A Subgroups Subgroups Page 12 of 16 USE ULTRA37000TM FOR ALL NEW DESIGNS CY7C344B Package Diagrams 28-Pin Windowed Leaded Chip Carrier H64 51-80077-** Document #: 38-03006 Rev. *A Page 13 of 16 USE ULTRA37000TM FOR ALL NEW DESIGNS CY7C344B Package Diagrams (continued) 28-Lead Plastic Leaded Chip Carrier J64 51-85001-*A 28-Lead (300-Mil) PDIP P21 14 1 DIMENSIONS IN INCHES[MM] REFERENCE JEDEC MO-095 0.260[6.60] 0.280[7.11] 15 MIN. MAX. PART # 28 P28.3 STANDARD PKG. PZ28.3 LEAD FREE PKG. 0.030[0.76] 0.080[2.03] SEATING PLANE 1.370[34.79] 1.425[36.19] 0.290[7.36] 0.325[8.25] 0.120[3.05] 0.140[3.55] 0.140[3.55] 0.190[4.82] 0.115[2.92] 0.160[4.06] 0.015[0.38] 0.060[1.52] 0.090[2.28] 0.110[2.79] Document #: 38-03006 Rev. *A 0.055[1.39] 0.065[1.65] 0.015[0.38] 0.020[0.50] 0.009[0.23] 0.012[0.30] 3 MIN. 0.310[7.87] 0.385[9.78] 51-85014-*C Page 14 of 16 USE ULTRA37000TM FOR ALL NEW DESIGNS CY7C344B Package Diagrams (continued) 28-Lead (300-Mil) Windowed CerDIP W22 MIL-STD-1835 D-15 Config. A 51-80087-** MAX and Warp are registered trademarks and Ultra37000, Warp Professional and Warp Enterprise are trademarks of Cypress Semiconductor Corporation. All products and company names mentioned in this document may be the trademarks of their respective holders. Document #: 38-03006 Rev. *A Page 15 of 16 (c) Cypress Semiconductor Corporation, 2004. The information contained herein is subject to change without notice. Cypress Semiconductor Corporation assumes no responsibility for the use of any circuitry other than circuitry embodied in a Cypress Semiconductor product. Nor does it convey or imply any license under patent or other rights. Cypress Semiconductor does not authorize its products for use as critical components in life-support systems where a malfunction or failure may reasonably be expected to result in significant injury to the user. The inclusion of Cypress Semiconductor products in life-support systems application implies that the manufacturer assumes all risk of such use and in doing so indemnifies Cypress Semiconductor against all charges. USE ULTRA37000TM FOR ALL NEW DESIGNS CY7C344B Document History Page Document Title: CY7C344 32-Macrocell MAX(R) EPLD Document Number: 38-03006 Issue Date Orig. of Change REV. ECN NO. ** 106271 04/19/01 SZV Change from Spec number: 38-00127 to 38-03006 *A 213375 See ECN FSG Added note to title page: "Use Ultra37000 For All New Designs" Document #: 38-03006 Rev. *A Description of Change Page 16 of 16