3
G6S Surface-mounting Relay
G
6
S
■Characteristics
Note: The above values are initial values.
*1. The contact resistance was measured with 10 mA at 1 VDC with a voltage drop method.
*2. The insulation resistance was measured with a 500 VDC megohmmeter applied to the same parts as those used for checking the dielectric strength (except
between the set and reset coil).
*3. This value was measured at a switching frequency of 120 operations/min. This value may vary, depending on switching frequency, operating conditions, expected
reliability level of the relay, etc. It is always recommended to double-check relay suitability under actual load conditions.
■Engineering Data
Item Relay Function
Single-side Stable
G6S-2, G6S-2F,
G6S-2G
Single-winding Latching
G6SU-2, G6SU-2F,
G6SU-2G
Double-winding Latching
G6SK-2, G6SK-2F,
G6SK-2G
EN60950 certified
G6S-2F-Y, G6S-2G-Y,
G6S-2-Y
Contact resistance *1 75 mΩ max.
Operate (set) time 4 ms max.
Release (reset) time 4 ms max.
Min. set/reset pulse width −10 ms −
Insulation resistance *2 1,000 MΩ min. (at 500 VDC)
Dielectric
strength
Between coil and contacts 2,000 VAC, 50/60 Hz for 1 min 1,000 VAC, 50/60 Hz for 1
min
2,000 VAC, 50/60 Hz for 1
min
Between contacts of different polarity 1,500 VAC, 50/60 Hz for 1 min
Between contacts of the same polarity 1,500 VAC, 50/60 Hz for 1 min
Between set and reset coil −500 VAC, 50/60 Hz for 1
min −
Impulse
withstand
voltage
Between coil and contacts 2,500 V (2 × 10 μs); 1,500 V (10 × 160 μs) 1,500 V (10 × 160 μs) 2,500 V (2 × 10 μs);
1,500 V (10 × 160 μs)
Between contacts of different polarity 2,500 V (2 × 10 μs); 1,500 V (10 × 160 μs)
Between contacts of the same polarity 1,500 V (10 × 160 μs)
Vibration
resistance
Destruction 10 to 55 to 10 Hz, 2.5 mm single amplitude (5 mm double amplitude)
Malfunction 10 to 55 to 10 Hz, 1.65 mm single amplitude (3.3 mm double amplitude)
Shock
resistance
Destruction 1,000 m/s2
Malfunction 750 m/s2
Durability
Mechanical 100,000,000 operations min. (at 36,000 operations/hr)
Electrical 100,000 operations min. for AC (at 1,800 operations/h with rated load)
100,000 operations min. for DC (at 1,200 operations/h with rated load)
Failure rate (P level) (reference value) *3 10 μA at 10 m VDC
Ambient operating temperature -40°C to 85°C (with no icing or condensation), and -40°C to 70°C (with no icing or condensation) only for
double-winding latching 24 VDC type and EN60950 standard approved 24 VDC type
Ambient operating humidity 5% to 85%
Weight Approx. 2 g
●Maximum Switching
Capacity
●Durability
G6S-2F(G)
●Ambient Temperature
vs. Maximum Voltage
(Single-side Stable)
●Ambient Temperature
vs. Maximum Voltage
(Latching)
Note: “Maximum voltage” is the maximum voltage that can be applied to the Relay coil.
●Ambient Temperature
vs. Switching Current
(Single-side Stable)
●Ambient Temperature
vs. Switching Current
(Latching)
●Ambient Temperature
vs. Must Operate or Must
Release Voltage
G6S-2F(G)
●Shock Malfunction
G6S-2F(G)
Conditions: Shock is applied in ±X, ±Y, and
±Z directions three times each
with and without energizing the
Relays to check the number of
contact malfunctions.