Input Voltage: 90-264 VAC, 47-63 Hz
Input Current: <2A RMS @ 115 VAC @ full load
<1A RMS @ 230 VAC @ full load
Inrush Current: <35A, pk @ 132 VAC @ cold start
<75A, pk @ 264 VAC @ cold start
Power Factor: >0.98 @ full load @ 115/230VAC input
Harmonic Distortion: Meets EN61000-3-2
EMI Filtering: Meets CISPR 11 and 22 and FCC Part 15
Class B (conducted)
Input Protection: Internal AC line fuse; 250 VAC, 4.0A
Surge Withstand: Meets EN61000-4
Output Power: 130W with 15CFM air; 80W Convection
cooled (consult factory for current ratings)
Line Regulation: ± 0.3%
Load Regulation: ± 1% for V1 and V2
± 5% for V3 and V4
PARD: Greater of 1% or 50mV
20MHz bandwidth
Hold-up Time: >20 ms @ full load
Turn-on Delay: <2 seconds
Output Polarity: See Voltage Chart
Minimum Load: >0.5A for V1 and V2
>0.1A for V3 and V4
Transient Response: Greater of 150mV or 3% for 25%
load change @ 1A/μs (V1 and V2)
Output Rise Time: <100 ms (10% to 90%)
Remote Sense: Standard on V1 and V2
Up to 400mV of cable drop
AC Power Fail: TTLLOW logic “0” at least 5 ms before DC
output drops 5% (without signal jitter).
<10mA sink current for Power Fail "0".
<1mA source current for Power Fail "1".
Overshoot/Undershoot: <5% overshoot with remote sense at output
terminals
Current Share (option): Load currents of V1 and V2 for similar units
can be shared @ <±5% of total load
Overvoltage Protect: Factory set, 125% ±5% on V1 and V2
cycle AC to reset
Short Circuit Protection: All outputs are auto recovery
Reverse Voltage: Reverse current up to rated outputs
Case Power Protection: Standard operation interrupt (hiccup mode)
Efficiency: Up to 88%
MTBF: MIL-STD-HDBK 217E
>200,000 hours @ 25°C
Highly Accelerated Life Testing
Electrical Specifications
Voltage V1 V1 V2 V2 V3 V3 V4
**
V4
Codes Voltages Currents Voltages Currents Voltages Currents Voltages Currents
(Volts) (Amps) (Volts) (Amps) (Volts) (Amps) (Volts) (Amps)
-1
+1.8 14 +1.8 16 +1.8 1.5 -1.8 1.5
-2 +3.3 14 +3.3 16 +3.3 1.5 -3.3 1.5
-3 +5 14 +5 14 +5 1.5 -5 1.5
-4 +12 5 +12 1.5 -12 1.5
-5 +15 1.5 -15 1.5
-6 +24 1.5 -24 1.5
* Consult factory for other voltages and OEM quantities.
** Standard Polarity for V4 is negative (-). V4 is available with positive polarity as a Tailored or Custom model.
Note: Standard models are 3244, 3255, 3264, 3404 and 3464
Available Voltage Outputs*
AAD130
Model
130 Watts output power
Power Factor Correction
Parallel/Redundant Operation
Miniature Switch Mode Power Supply
H.A.L.T.
TESTED
Highly
Accelerated
Life
Testing
Up to 88% Efficiency
PART # STRUCTURE:
MODEL - VOLTAGE CODE - OPTION CODES (See back)
- V1 V2 V3 V4 -
AAD130 - X X X X - ABC....
Example: Part Number AAD130-3244-AM = 130W Power Factor Corrected, (V1) +5V @ 14A, (V2) +3.3V @ 16A, (V3) +12V @ 1.5A and
(V4) -12V @ 1.5A with Current Sharing and Metric Mounting.
CLICK HERE TO SEE THE AAD130 CODE TABLE AND AVAILABLE OPTIONS.
Physical Specifications
Dimensions: (HxWxL) 1.25" x 3.14" x 5"
Operating Temp: 0 to 50°C; rated power to 50°C
with 15CFM air
Relative Humidity: 5% to 90%, non-condensing
Storage: -50 to 85°C/20-90% RH
Altitude: 10,000' operating;
40,000' storage
Options (code)
#6-32 PEM Nut (Standard) Current Sharing (A)
PF Invert (B) Thru-Hole Mounting (C)
Metric Mounting (M) PF Open Collector (O)
Input and Options with Gold Pins (G)
Molex Output Connector with Gold Pins (J)
Molex Connectors with Standard Pins (K)
Model
Certifications
UL60950-1 CSA C22.2 No. 60950-1
IEC60950-1 EN60950-1
Compliance
EN61000-4-5 Level 3 EN61000-4-2 Level 2
EN61000-3-2 EN61000-4-2 Level 3 (Air Only)
EN61000-4-4 Level 3 EN61000-4-11
CISPR 11 and 22 FCC Part 15 Class B (conducted)
FM 32227
© Copyright 2011 TAMURA CORPORATION OF AMERICA. Specifications subject to change without notice.
TAMURA CORPORATION OF AMERICA
1040 South Andreasen Drive, STE. 100, Escondido, CA 92029-1951
(951) 699-1270 / Fax: (951) 676-9482
(800) 472-6624
www.tamuracorp.com
AAD130