Input Voltage: 90-264 VAC, 47-63 Hz
Input Current: <2A RMS @ 115 VAC @ full load
<1A RMS @ 230 VAC @ full load
Inrush Current: <35A, pk @ 132 VAC @ cold start
<75A, pk @ 264 VAC @ cold start
Power Factor: >0.98 @ full load @ 115/230VAC input
Harmonic Distortion: Meets EN61000-3-2
EMI Filtering: Meets CISPR 11 and 22 and FCC Part 15
Class B (conducted)
Input Protection: Internal AC line fuse; 250 VAC, 4.0A
Surge Withstand: Meets EN61000-4
Output Power: 130W with 15CFM air; 80W Convection
cooled (consult factory for current ratings)
Line Regulation: ± 0.3%
Load Regulation: ± 1% for V1 and V2
± 5% for V3 and V4
PARD: Greater of 1% or 50mV
20MHz bandwidth
Hold-up Time: >20 ms @ full load
Turn-on Delay: <2 seconds
Output Polarity: See Voltage Chart
Minimum Load: >0.5A for V1 and V2
>0.1A for V3 and V4
Transient Response: Greater of 150mV or 3% for 25%
load change @ 1A/μs (V1 and V2)
Output Rise Time: <100 ms (10% to 90%)
Remote Sense: Standard on V1 and V2
Up to 400mV of cable drop
AC Power Fail: TTLLOW logic “0” at least 5 ms before DC
output drops 5% (without signal jitter).
<10mA sink current for Power Fail "0".
<1mA source current for Power Fail "1".
Overshoot/Undershoot: <5% overshoot with remote sense at output
terminals
Current Share (option): Load currents of V1 and V2 for similar units
can be shared @ <±5% of total load
Overvoltage Protect: Factory set, 125% ±5% on V1 and V2
cycle AC to reset
Short Circuit Protection: All outputs are auto recovery
Reverse Voltage: Reverse current up to rated outputs
Case Power Protection: Standard operation interrupt (hiccup mode)
Efficiency: Up to 88%
MTBF: MIL-STD-HDBK 217E
>200,000 hours @ 25°C
Highly Accelerated Life Testing
Electrical Specifications
Voltage V1 V1 V2 V2 V3 V3 V4
**
V4
Codes Voltages Currents Voltages Currents Voltages Currents Voltages Currents
(Volts) (Amps) (Volts) (Amps) (Volts) (Amps) (Volts) (Amps)
-1
+1.8 14 +1.8 16 +1.8 1.5 -1.8 1.5
-2 +3.3 14 +3.3 16 +3.3 1.5 -3.3 1.5
-3 +5 14 +5 14 +5 1.5 -5 1.5
-4 +12 5 +12 1.5 -12 1.5
-5 +15 1.5 -15 1.5
-6 +24 1.5 -24 1.5
* Consult factory for other voltages and OEM quantities.
** Standard Polarity for V4 is negative (-). V4 is available with positive polarity as a Tailored or Custom model.
Note: Standard models are 3244, 3255, 3264, 3404 and 3464
Available Voltage Outputs*
AAD130
Model
130 Watts output power
Power Factor Correction
Parallel/Redundant Operation
Miniature Switch Mode Power Supply
H.A.L.T.
TESTED
Highly
Accelerated
Life
Testing
Up to 88% Efficiency
PART # STRUCTURE:
MODEL - VOLTAGE CODE - OPTION CODES (See back)
- V1 V2 V3 V4 -
AAD130 - X X X X - ABC....
Example: Part Number AAD130-3244-AM = 130W Power Factor Corrected, (V1) +5V @ 14A, (V2) +3.3V @ 16A, (V3) +12V @ 1.5A and
(V4) -12V @ 1.5A with Current Sharing and Metric Mounting.