Miniature Switch Mode Power Supply Model AAD130 H.A.L.T. TESTED 130 Watts output power Highly Accelerated Life Testing Power Factor Correction Parallel/Redundant Operation Up to 88% Efficiency Electrical Specifications Input Voltage: 90-264 VAC, 47-63 Hz Input Current: <2A RMS @ 115 VAC @ full load <1A RMS @ 230 VAC @ full load Inrush Current: <35A, pk @ 132 VAC @ cold start <75A, pk @ 264 VAC @ cold start Power Factor: >0.98 @ full load @ 115/230VAC input Harmonic Distortion: Meets EN61000-3-2 EMI Filtering: Meets CISPR 11 and 22 and FCC Part 15 Class B (conducted) Input Protection: Internal AC line fuse; 250 VAC, 4.0A Surge Withstand: Meets EN61000-4 Output Power: 130W with 15CFM air; 80W Convection cooled (consult factory for current ratings) Line Regulation: 0.3% Load Regulation: Remote Sense: Standard on V1 and V2 Up to 400mV of cable drop AC Power Fail: 1% for V1 and V2 5% for V3 and V4 TTLLOW logic "0" at least 5 ms before DC output drops 5% (without signal jitter). <10mA sink current for Power Fail "0". <1mA source current for Power Fail "1". Overshoot/Undershoot: PARD: Greater of 1% or 50mV 20MHz bandwidth <5% overshoot with remote sense at output terminals Current Share (option): Load currents of V1 and V2 for similar units can be shared @ <5% of total load Overvoltage Protect: Factory set, 125% 5% on V1 and V2 cycle AC to reset Short Circuit Protection: All outputs are auto recovery Hold-up Time: >20 ms @ full load Turn-on Delay: <2 seconds Output Polarity: See Voltage Chart Minimum Load: >0.5A for V1 and V2 >0.1A for V3 and V4 Transient Response: Greater of 150mV or 3% for 25% load change @ 1A/s (V1 and V2) Output Rise Time: <100 ms (10% to 90%) Reverse Voltage: Reverse current up to rated outputs Case Power Protection: Standard operation interrupt (hiccup mode) Efficiency: Up to 88% MTBF: MIL-STD-HDBK 217E >200,000 hours @ 25C Highly Accelerated Life Testing Available Voltage Outputs* Voltage Codes ** V1 Voltages (Volts) V1 Currents (Amps) V2 Voltages (Volts) V2 Currents (Amps) V3 Voltages (Volts) V3 Currents (Amps) V4 Voltages (Volts) -1 +1.8 14 +1.8 16 +1.8 1.5 -1.8 -2 +3.3 14 +3.3 16 +3.3 1.5 -3.3 1.5 -3 +5 14 +5 14 +5 1.5 -5 1.5 +12 5 -4 V4 Currents (Amps) 1.5 +12 1.5 -12 1.5 -5 +15 1.5 -15 1.5 -6 +24 1.5 -24 1.5 * Consult factory for other voltages and OEM quantities. ** Standard Polarity for V4 is negative (-). V4 is available with positive polarity as a Tailored or Custom model. Note: Standard models are 3244, 3255, 3264, 3404 and 3464 PART # STRUCTURE: MODEL VOLTAGE CODE OPTION CODES (See back) V1 V2 V3 V4 AAD130 X X X X ABC.... Example: Part Number AAD130-3244-AM = 130W Power Factor Corrected, (V1) +5V @ 14A, (V2) +3.3V @ 16A, (V3) +12V @ 1.5A and (V4) -12V @ 1.5A with Current Sharing and Metric Mounting. CLICK HERE TO SEE THE AAD130 CODE TABLE AND AVAILABLE OPTIONS. Model AAD130 Options (code) Certifications #6-32 PEM Nut (Standard) Current Sharing (A) PF Invert (B) Thru-Hole Mounting (C) Metric Mounting (M) PF Open Collector (O) Input and Options with Gold Pins (G) Molex Output Connector with Gold Pins (J) Molex Connectors with Standard Pins (K) UL60950-1 IEC60950-1 CSA C22.2 No. 60950-1 EN60950-1 Physical Specifications Dimensions: (HxWxL) 1.25" x 3.14" x 5" Compliance Operating Temp: EN61000-4-5 Level 3 EN61000-4-2 Level 2 EN61000-3-2 EN61000-4-2 Level 3 (Air Only) EN61000-4-4 Level 3 EN61000-4-11 CISPR 11 and 22 FCC Part 15 Class B (conducted) 0 to 50C; rated power to 50C with 15CFM air Relative Humidity: 5% to 90%, non-condensing Storage: -50 to 85C/20-90% RH Altitude: 10,000' operating; 40,000' storage (c) Copyright 2011 TAMURA CORPORATION OF AMERICA. Specifications subject to change without notice. TAMURA CORPORATION OF AMERICA 1040 South Andreasen Drive, STE. 100, Escondido, CA 92029-1951 (951) 699-1270 / Fax: (951) 676-9482 (800) 472-6624 www.tamuracorp.com FM 32227