LTC Batteries SL-350 Size: 1/2AA Standard use and stand-by Performance Data (Typical values for batteries stored at +25 C for one year) 4.0 System Nominal voltage Nominal capacity Nominal current Max. continuous discharge current Anode surface area Lithium content Weight Volume Temperature range 3.5 Lithium Thionyl Chloride 3.6 V 1.2 Ah 0.6 mA 6 mA 6 cm2 0.35 g 9.6 g 4 cm3 -55 C ... +85 C Typical Discharge Curves at +25 C Voltage / V 3.0 1 2.5 2.0 1.0 0.5 1.2 3 4 5 1: 560 ~6 mA 2: 1.8 k ~2 mA 3: 5.6 k ~0.6 mA 4: 18 k ~0.2 mA 5: 56 k ~0.06 mA 6: 180 k ~0.02 mA 7: 560 k ~0.006 mA 1.5 0.0 2 0.1 1 10 102 Time / h 103 6 7 0.90 Ah 1.10 Ah 1.20 Ah 1.15 Ah 1.05 Ah 0.95 Ah 0.85 Ah 104 105 Available Capacity SL-350/S +0.2 -0.3 25.2-1.2 0.70.3 O 4.2 SL-350/T Capacity to 2 Volts / Ah 4 1.0 3 2 0.8 5 1 0.6 1: 2: 3: 4: 5: 0.4 0.2 +72 C +55 C +25 C 0 C -30 C 0.0 0.01 70.5 0.1 1 10 Current / mA 3.17 100 1000 0.15 thick SL-350/P 3.8 5 4 3.4 Voltage / V O 0.8 45 Operating Voltage 3.6 O 0.8 O 14.7-1.2 45 3 3.2 2 3.0 2.8 1 6 mA 1: 2 mA 2: 3: 0.6 mA 4: 0.2 mA 5: 0.02 mA 2.6 SL-350/PR SL-350/PT 2.4 10 25 40 55 Temperature / C 70 85 100 3.5 4+0.5 1-0.1 1-0.1 0.2 thick 0.2 thick Available Terminations Catalogue No. SL-350/S SL-350/T SL-350/P SL-350/PR SL-350/PT 11 1 03501 00 11 1 03502 00 11 1 03503 00 11 1 03506 00 11 1 03508 00 Standard Tags Pins Pins radial Polarized tags 10.16 WARNING: Fire, explosion, and severe burn hazard. Do not recharge, disassemble, heat above 100 C, incinerate, or expose contents to water. Any values given here are for informational purposes only. They also depend on actual conditions of use and are not warranties of future performance. Subject to change. PDC13Eng 3.5 4+0.5 -50 -35 -20 -5 6 Tadiran Batteries GmbH * Industriestr. 22 * 63654 BUDINGEN GERMANY * Tel.: +49 (0)6042 954-0 * www.tadiranbatteries.de