Panel feed-through terminal block-UWV 16-POT-3073542
Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's
documentation. Our General Terms of Use for Downloads are valid
(http://phoenixcontact.com/download)
Panel feed-through terminal block, connection method: Screw connection with tension sleeve, Cable lug
connection, number of positions: 1, load current: 76 A, cross section: 6 mm²-25 mm², connection direction of the
conductor to plug-in direction: -90 °, width: 12.1 mm, color: gray
The figure shows a 7-position
version
Your advantages
Easy grouping with engagement pin versions
Both terminal halves can be easily assembled by simply snapping them together
Touch-proof insulating housing in a new design
Molded versions ensure maximum tightness of seal
Universal screw connection with screw locking
Spacer plates increase clearances and creepage distances
Automatic compensation of the panel thickness via the snap principle integrated in the insulation housing
Well-known connection principle allows worldwide use
Low temperature rise, thanks to maximum contact force
Tool-free snap-in principle enables easy mounting on the device panel
Automatic panel thickness compensation enables universal use
Reliable seal even with low-viscosity molding compounds
Key Commercial Data
Packing unit 1 pc
Minimum order quantity 50 pc
GTIN
GTIN 4046356344784
Weight per Piece (excluding packing) 30.000 g
Custom tariff number 85369010
Country of origin China
https://www.phoenixcontact.com/us/products/3073542
05/29/2020Page2/9
Panel feed-through terminal block-UWV 16-POT-3073542
Technical data
Item properties
Brief article description Panel feed-through terminal block
Range of articles UWV 16-POT
Pitch 12.1 mm
Number of positions 1
Connection method Screw connection with tension sleeve
Number of connections 2
Number of potentials 1
Electrical parameters
Nominal current 76 A
Nom. voltage 500 V
Rated voltage 500 V
Rated surge voltage (III/3) 6 kV
Connection capacity, external
Connection method Screw connection with tension sleeve
Connection direction of the conductor to plug-in direction -90 °
Conductor cross section solid 6 mm² ... 25 mm²
Conductor cross section flexible 6 mm² ... 16 mm²
Conductor cross section flexible, with ferrule without plastic sleeve 6 mm² ... 16 mm²
Conductor cross section, flexible, with ferrule, with plastic sleeve 6 mm² ... 16 mm²
2 conductors with same cross section, solid 2.5 mm² ... 10 mm²
2 conductors with same cross section, flexible 2.5 mm² ... 6 mm²
2 conductors with same cross section, flexible, with ferrule without plastic
sleeve 4 mm² ... 6 mm²
2 conductors with the same cross section, flexible, with TWIN ferrule with
plastic sleeve 4 mm² ... 6 mm²
Internal cylindrical gage B7
Stripping length 16 mm
Torque 2.5 Nm ... 3 Nm
Connection capacity, internal
Connection method Cable lug connection
Connection direction of the conductor to plug-in direction 0 °
Material data - contact
Note WEEE/RoHS-compliant, free of whiskers according to IEC 60068-2-82/
JEDEC JESD 201
Contact material Cu alloy
Surface characteristics tin-plated
https://www.phoenixcontact.com/us/products/3073542
05/29/2020Page3/9
Panel feed-through terminal block-UWV 16-POT-3073542
Technical data
Material data - housing
Insulating material PA
Insulating material group I
CTI according to IEC 60112 600
Flammability rating according to UL 94 V0
Glow wire flammability index GWFI according to EN60695-2-12 850
Glow wire ignition temperature GWIT according to EN60695-2-13 775
Temperature for the ball pressure test according to EN60695-10-2 125 °C
Dimensions for the product
Width [ w ] 12.1 mm
Pitch 12.1 mm
Packaging information
Pieces per package 50
Denomination packing units Pcs.
General product information
Type of note Notes on safety
Note on application
Note
The cable entry funnel is not touch-proof. Never connect or disconnect
the terminal when it is energized. Take appropriate steps to ensure touch
proofness.
To maintain the nominal voltage, align the cable lugs straight and centered,
and cast the terminals on the inside.
Termination and connection method
Test for conductor damage and slackening IEC60947-7-1:2009-04
Test passed
Pull-out test
Pull-out test IEC60947-7-1:2009-04
Test passed
Mechanical tests according to standard
Test specification IEC 60947-7-1 (following)
Electrical tests
Rated current 76 A
Conductor cross section 16 mm²
Air clearances and creepage distances
Clearances and creepage distances without spacer plate IEC60947-7-1:2009-04
Application without spacer plate
https://www.phoenixcontact.com/us/products/3073542
05/29/2020Page4/9
Panel feed-through terminal block-UWV 16-POT-3073542
Technical data
Air clearances and creepage distances
Specification IEC60947-7-1:2009-04
Minimum clearance - inhomogeneous field (III/3) 5.5 mm
Minimum creepage distance value (III/3) 6.3 mm
Temperature-rise test
Result Test passed
Specification IEC60947-7-1:2009-04
Current carrying capacity / derating curves
Specification IEC 60947-7-1 (following)
Standards and Regulations
Connection in acc. with standard UL
IEC60947-7-1
Flammability rating according to UL 94 V0
Safety note
• WARNING: Only electrically qualified personnel may install and operate
the product. They must observe the following safety notes. The qualified
personnel must be familiar with the basics of electrical engineering. They
must be able to recognize and prevent danger. The relevant symbol on the
packaging indicates that only personnel familiar with electrical engineering
are allowed to install and operate the product.
• The installation notes/Design In documents online on the download page
at phoenixcontact.com/products must be observed for this product.
• The cable entry funnel is not safe to touch. Never connect or disconnect
the terminal when it is energized. Take appropriate steps to ensure touch
protection.
• To maintain the nominal voltage, align the cable lugs straight and
centered, and cast the terminals on the inside.
Environmental Product Compliance
China RoHS Environmentally friendly use period: unlimited = EFUP-e
No hazardous substances above threshold values
Drawings
https://www.phoenixcontact.com/us/products/3073542
05/29/2020Page5/9
Panel feed-through terminal block-UWV 16-POT-3073542
Dimensional drawing
* Only when using the UW...‑F flange plate
** Dimensions when using the DP-UW... spacer plate
Dimensional drawing
https://www.phoenixcontact.com/us/products/3073542
05/29/2020Page6/9
Panel feed-through terminal block-UWV 16-POT-3073542
Classifications
eCl@ss
eCl@ss 10.0.1 27141134
eCl@ss 4.0 27141100
eCl@ss 4.1 27141100
eCl@ss 5.0 27141100
eCl@ss 5.1 27141100
eCl@ss 6.0 27141100
eCl@ss 7.0 27141134
eCl@ss 8.0 27141134
eCl@ss 9.0 27141134
ETIM
ETIM 2.0 EC001283
ETIM 3.0 EC001283
ETIM 4.0 EC001283
ETIM 5.0 EC001283
ETIM 6.0 EC001283
ETIM 7.0 EC001283
UNSPSC
UNSPSC 6.01 30211811
UNSPSC 7.0901 39121410
UNSPSC 11 39121410
UNSPSC 12.01 39121410
UNSPSC 13.2 39121410
UNSPSC 18.0 39121410
UNSPSC 19.0 39121410
UNSPSC 20.0 39121410
UNSPSC 21.0 39121410
Approvals
Approvals
Approvals
CSA / EAC / cULus Recognized
Ex Approvals
https://www.phoenixcontact.com/us/products/3073542
05/29/2020Page7/9
Panel feed-through terminal block-UWV 16-POT-3073542
Approvals
Approval details
CSA http://www.csagroup.org/services-industries/product-listing/ 2618381-158887
B C
Nominal voltage UN 600 V 600 V
Nominal current IN 80 A 80 A
mm²/AWG/kcmil 10-4 10-4
EAC B.01687
cULus Recognized http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm E60425-20100423
B C
Nominal voltage UN 600 V 600 V
Nominal current IN 85 A 85 A
mm²/AWG/kcmil 10-4 10-4
Accessories
Accessories
Screwdriver tools
Screwdriver-SZS 1,0X4,0 VDE-1205066
Screwdriver, slot-headed, VDE insulated, size: 1.0 x 4.0 x 100 mm, 2-component grip, with non-slip grip
Terminal marking
https://www.phoenixcontact.com/us/products/3073542
05/29/2020Page8/9
Panel feed-through terminal block-UWV 16-POT-3073542
Accessories
Marker for terminal blocks-UC-TM 12-0819194
Marker for terminal blocks, Sheet, white, unlabeled, can be labeled with: BLUEMARKIDCOLOR, BLUEMARKID,
BLUEMARK CLED, PLOTMARK, CMS-P1-PLOTTER, mounting type: snap into tall marker groove, for terminal block
width: 12 mm, lettering field size: 11.45 x 10.5 mm, Number of individual labels: 40
Marker for terminal blocks-UC-TMF 12-0819233
Marker for terminal blocks, Sheet, white, unlabeled, can be labeled with: BLUEMARKIDCOLOR, BLUEMARKID,
BLUEMARK CLED, PLOTMARK, CMS-P1-PLOTTER, mounting type: snap into flat marker groove, for terminal block
width: 12 mm, lettering field size: 11.45 x 5.1 mm, Number of individual labels: 40
Zack marker strip-ZB 12:UNPRINTED-0812120
Zack marker strip, Strip, white, unlabeled, can be labeled with: PLOTMARK, CMS-P1-PLOTTER, mounting type: snap
into tall marker groove, for terminal block width: 12.2 mm, lettering field size: 12 x 10.5 mm, Number of individual labels:
5
Zack Marker strip, flat-ZBF 12:UNBEDRUCKT-0809735
Zack Marker strip, flat, Strip, white, unlabeled, can be labeled with: PLOTMARK, CMS-P1-PLOTTER, mounting type:
snap into flat marker groove, for terminal block width: 12 mm, lettering field size: 5.15 x 12.15 mm, Number of individual
labels: 5
Marker for terminal blocks-TMT 100 R-0816605
Marker for terminal blocks, Roll, white, unlabeled, can be labeled with: THERMOMARK ROLL 2.0, THERMOMARK
ROLL, THERMOMARK ROLL X1, THERMOMARK ROLLMASTER 300/600, THERMOMARK X1.2, THERMOMARK
S1.1, unperforated, mounting type: snap into universal marker groove, snap into flat marker groove, for terminal block
width: 100 mm, lettering field size: 6.35 x 101.5 mm, Number of individual labels: 1000
https://www.phoenixcontact.com/us/products/3073542
05/29/2020Page9/9
Panel feed-through terminal block-UWV 16-POT-3073542
Accessories
Marker for terminal blocks-TMT (EX9,5)R-0828295
Marker for terminal blocks, Roll, white, unlabeled, can be labeled with: THERMOMARK ROLL 2.0, THERMOMARK
ROLL, THERMOMARK ROLL X1, THERMOMARK ROLLMASTER 300/600, THERMOMARK X1.2, mounting type: snap
into universal marker groove, snap into tall marker groove, for terminal block width: 50000 mm, lettering field size: 9.5 x
50000 mm, Number of individual labels: 1