• North America Tel: 800.366.2266 • Europe Tel: +353.21.244.6400
• India Tel: +91.80.4155721 • China Tel: +86.21.2407.1588
Visit www.macomtech.com for additional data sheets and prod uct information.
M/A-COM Technology Solutions Inc. and its affiliates reserve the right to make
changes to the product(s) or information contained herein without notice.
2
Termination Insensitive Mixer,
1 MHz - 3.5 GHz
Rev. V5
MD- / MDC- / MDS-169
ADVANCED: Data Sheets contain information regarding a product M/A-COM Technology Solutions
is considering for development. Performance is based on target specifications, simulated results,
and/or prototype measurements. Commitment to develop is not guaranteed.
PRELIMINARY: Data Sheets contain information regarding a product M/A-COM Technology
Solutions has under development. Performance is based on engineering tests. Specifications are
typical. Mechanical outline has been fixed. Engineering samples and/or test data may be available.
Commitment to produce in volume is not guaranteed.
Electrical Specifications1: TA = -55°C to +85°C
Parameter Test Conditions Frequency Units Min Typ Max
Frequency Range RF, LO Ports
IF Port 0.001 - 3.5
5 - 1500 GHz
MHz —
— —
— —
—
Conversion Loss 5 - 1000 MHz2
5 - 3000 MHz3
1 - 3500 MHz
dB
dB
dB
—
—
—
—
—
—
7
8
10
Isolation LO to RF 5 - 1000 MHz
1 - 3500 MHz dB
dB 30
20 —
— —
—
LO to IF 5 - 1000 MHz
1 - 3500 MHz dB
dB 30
20 —
— —
—
RF to IF 10 - 500 MHz
1 - 3000 MHz
1 - 3500 MHz
dB
dB
dB
30
20
18
—
—
—
—
—
—
RF Input 1 dB Compression
1 dB Desensitization —
— dBm
dBm —
— +7
+5 —
—
SSB Noise Figure Within 1 dB of Conversion Loss
Max — — — — —
Typical Two-Tone IM
Ratio Pin = –10 dBm per tone
IF = 60 MHz 10 MHz
500 MHz
3000 MHz
dB
dB
dB
—
—
—
55
58
56
—
—
—
3rd Order
Intermodulation Ratio
Degradation
@ IF VSWR 3:1 — dB — 3 —
1. All specifications apply when operated at +10 dBm available LO power with 50 Ohm source and load impedance.
2. For IF Frequencies of 5 - 300 MHz and RF of –10 dBm or less.
3. For MDC-169, add 1.0 dB to conv ersion loss.
Parameter Test Conditions Frequency Units Min Typ Max
Conversion Loss LO @ +10 dBm
IF @ 60 MHz 5 - 1000 MHz
1000 - 3000 MHz
1 - 3500 MHz
dB
dB
dB
—
—
—
6.5
7.5
8.0
7.0
9.0
10.0
Isolation LO to RF 5 - 1000 MHz
1 - 3500 MHz dB
dB 30
20 35
25 —
—
LO to IF 5 - 1000 MHz
1 - 3500 MHz dB
dB 30
20 35
25 —
—
RF to IF 10 - 500 MHz
1 - 3000 MHz
1 - 3500 MHz
dB
dB
dB
30
20
18
35
25
23
—
—
—
Electrical Specifications (MDS-169): TA = -55°C to +85°C
Frequency: RF, LO Ports = 1 - 3500 MHz, IF Port = 5-1500 MHz