Honeywell Pressure Switches
High Pressure: HP Series, HE Series
Factory set 150 psi to 4500 psi [10,34 bar to 310,26 bar]
Low Pressure: LP Series, LE Series
Factory set or eld adjustable 3.5 psi to 150 psi [0,24 bar to 10,34 bar]
Datasheet
2sensing.honeywell.com
Honeywell Pressure Switches
HP Series, HE Series, LP Series, LE Series
Honeywell Pressure Switches are durable, reliable electromechanical gauge pressure on/off switches that are available
with either single pole single throw (SPST) normally open or normally closed circuitry, or single pole double throw
(SPDT) circuitry. Their IP67 environmental sealing and high proof pressure and burst pressure ratings allow for use in
many rugged applications that require the making or breaking of an electrical connection in response to a pressure
change of the system media.
The media (gas or liquid) pressure is applied via the port of the switch to a diaphragm or sealed piston. A pre-
compressed spring on the other side of the sealed piston or diaphragm controls the set-point pressure. If the force
resulting from the pressure is greater than the load on the spring, the electrical contacts within the switch will change
state. If the contacts are normally open when no pressure is applied, they close on increasing pressure when the
set point is reached. On decreasing pressure, the contacts will open again at a pressure somewhat less than the set
switching point. The difference between the activation point on increasing pressure and the deactivation point on
decreasing pressure is called hysteresis. The set point pressure for the switch can be configured such that the switch
will actuate on increasing or decreasing system pressure.
LONG LIFE • HIGH PRODUCTIVITY • RELIABLE SWITCHING
Potential Applications
TRANSPORTATION
Agricultural machinery
Heavy duty construction machinery
Heavy duty trucks
Lawn & garden
Marine vessels
Material handling machinery
• Railway
INDUSTRIAL
CNC machines
Compressors, boilers
Fracking equipment
Food & beverage equipment
• Generators
HVAC/R equipment
Mud pumps
Pneumatic equipment
Presses and punches
Pressure washers
Trash compactors
Water jet cutting machines
Water pumps
Features
Life cycle rating: up to 2 million
IP67 sealing rating
Operating temperature range: -40 °C to 120 °C
[-40 °F to 248 °F]
Proof pressure: 10000 psi [689 bar] (High Pressure),
500 psi [34,47 bar] (Low Pressure)
Burst pressure: 20000 psi [1379 bar] (High Pressure),
750 psi for 3.5 psi to 22 psi, 1250 psi > 22 psi (Low Pressure)
Hysteresis option (HP, HE, and LP Series only)
Variety of pressure ports and electrical terminations
Pressure switching set point range: Factory set 150 psi to
4500 psi [10,34 bar to 310,26 bar] (High Pressure) or factory
set or eld adjustable 3.5 psi to 150 psi [0,24 bar to 10,34 bar]
(Low Pressure)
Switching point accuracy: up to ±2 %
3
sensing.honeywell.com
Honeywell Pressure Switches
Table 2. Specifications
Characteristic HP Series HE Series LP Series LE Series
Product length
(connector version AMP
Super Seal)
see page 5 see page 5 see page 6 see page 6
Product length (blade) see page 5 see page 5 see page 6 see page 6
Product length
(wire
out)
see page 5 see page 5 see page 6 see page 6
Hex size 27 mm 27 mm 27 mm 27 mm
Ease of installation box spanner box spanner box spanner box spanner
Snap-action switch yes yes yes no
Set point1 range 150 psi to 4500 psi 150 psi to 4500 psi 3.5 psi to 150 psi 3.5 psi to 150 psi
Set point ranges 6 6 4 4
Set point
accuracy @ 25 °C
(before test)
150 psi to 500 psi (±5 %)
500 psi to 4000 psi (±3.5 %)
>4000 psi (±2 % [up to 2 %])
150 psi to 1000 psi (±14%)
1000 psi to 2000 psi (±12 %)
2000 psi to 4000 psi (±11 %)
>4000 psi (±10 % [up to 10 %])
for 3.5 psi to 10 psi (±1 psi),
for >10 psi to 50 psi (±3 psi),
for >50 psi to 100 psi (±7 psi),
for >100 psi to 150 psi (±10 psi)
for 3.5 psi to 10 psi (±1 psi),
for >10 psi to 50 psi (±3 psi),
for >50 psi to 100 psi (±7 psi),
for >100 psi to 150 psi (±10 psi)
Average deadband n/a n/a n/a
for 3.5 psi to 10 psi (±2.8 psi),
for >10 psi to 50 psi (±14 psi),
for >50 psi to 100 psi (±38 psi),
for >100 psi to 150 psi (±40 psi)
Operating pressure25,000 psi max. 5,000 psi max. 250 psi max. 250 psi max.
Proof pressure3 10,000 psi 10,000 psi 500 psi 500 psi
Hysteresis 5 % to 55 %
(based on set point range)
3 % to 65 %
(based on set point range)
3 % to 50 %
(based on set point range) n/a
Burst pressure420,000 psi 20,000 psi
750 psi for set points
3.5 psi to 22 psi,
1250 psi for set points
> 22 psi
750 psi for set points
3.5 psi to 22 psi,
1250 psi for set points
> 22 psi
Current rating (resistive) 5 A at 250 Vac
5 A at 24 Vdc
5 A at 250 Vac
3 A at 24 Vdc
7.5 mA to 5 A,
24 Vdc and 250 Vac
7.5 mA to 3 A,
24 Vdc and 250 Vac
Current rating
(inductive)
5 A at 115 Vac (SX rating)
3 A at 28 Vdc n/a 1 A at 28 Vdc n/a
Temperature rating -40 °C to 120 °C
[-40 °F to 248 °F]
-40 °C to 85 °C
[-40 °F to 185 °F]
-40 °C to 120 °C
[-40 °F to 248 °F]
-40 °C to 120 °C
[-40 °F to 248 °F]
Media connection multiple ports available multiple ports available multiple ports available multiple ports available
Pressure ports M14 × 1.5, M18 × 1.5, 1/2-20 UNF, 9/16-18 UNF,
3/4-16 UNF, 7/8-14 UNF
1/4-18 NPT,1/8-27 NPT,
1/2-20 UNF,1/8-27 PTF,
M12 × 1.5, M14 × 1.5,
9/16-18 UNF, 3/4-16 UNF,
G1/8 BSPP, 7/16-20 UNF,
R1/8 BSPT, M10 × 1.0,
R1/2 BSPT, G1/4 BSPP,
R1/4 BSPT
1/4-18 NPT,1/8-27 NPT,
1/2-20 UNF, 1/8-27 PTF,
M12 × 1.5, M14 × 1.5,
9/16-18 UNF, 3/4-16 UNF,
G1/8 BSPP, 7/16-20 UNF,
R1/8 BSPT, M10 × 1.0,
R1/2 BSPT, G1/4 BSPP,
R1/4 BSPT
4sensing.honeywell.com
HP Series, HE Series, LP Series, LE Series
Characteristic HP Series HE Series LP Series LE Series
Termination
AA = Spade Terminals
BA = Screw Terminals
CA = Deutsch DT04-3P-E005 (3-Pin Connector)
DA = Amp Super Seal 1.5 - 282105-1 (3-Pin Connector)
EA = 10-inch Cable, 18 AWG (Wire Out, No Connector)
FA = 10-inch Cable w/Deutsch DT04-3P-E005 (3-Pin Connector) (16 AWG)*
GA = 10-inch Cable w/Amp Super Seal 1.5 - 282105-1 (3-Pin Connector) (18 AWG)*
HA = 10-inch Cable w/Metripack 280 Delphi 15300002 (2-Pin Connector) (18 AWG)*
JA = 10-inch Cable w/Din43650-C (3-Pin Connector) (18 AWG)*
KA = 10-inch Cable w/M12x1 (Brad Harrison Micro) - 21032121306 Harting P/N (3-Pin Connector) (18 AWG)*
LA = 10-inch Cable w/Packard Weatherpack Male Terminal - 12020827 (3-Pin Connector) (18 AWG)
MA = 10-inch Cable w/Deutsch DT04-2P-E005 (2-Pin Connector) (18 AWG)
NA = 3-inch Cable w/Packard 2P Tower Connector - 12015792 (2-Pin Connector) (18 AWG)
PA = 2.75-inch Cable w/Packard 2P Shroud Connector - 12010973 (2-Pin Connector) (18 AWG)
RA = 4-inch Cable w/Packard 2P Shroud Connector - 12010973 (2-Pin Connector) (16 AWG)
SA = 5.5-inch Cable w/ITT Cannon 2P Sure-Seal Circular Connector - SS2R-120-1804-000 (2-Pin Connector) (18 AWG)
TA = 8.5-inch Cable w/ITT Cannon 3P Sure-Seal Circular Connector - SS3R-120-8551-001 (3-Pin Connector) (16 AWG)*
UA = 10-inch Cable - Vacuum Impregnated w/Deutsch DT06-3S-EP06 (3-Socket Connector) (16 AWG)*
VA = 10-inch Cable - Vacuum Impregnated w/Deutsch DT04-3P-E005 (3-Pin Connector) (16 AWG)*
WA = 4.5-inch Cable w/Blade Terminals 6,3 mm x 0,8 mm (16 AWG)*
YA = 6-inch Cable w/Amp Super Seal 1.5 - 282104-1 (2-Pin Connector) (18 AWG)*
ZA = 10-inch Cable w/Deutsch DT06-2S-CE06 (2-Socket Connector) (18 AWG)
AB = Deutsch DT04-2P-E005 (2-Pin Connector)**
BB = 10-inch Cable w/Metripack 150 Delphi 12129615 (3-Pin Connector) (18 AWG)*
DB = 10-inch Cable w/AMP 2,5 mm System Series Connector 1-967402-1 (18 AWG)*
EB = 4.5-inch Cable w/Packard Shroud Connector 12015792 (2-Pin Connector) (18 AWG)
FB = 10-inch Cable w/Metripack 150 Delphi 12052641 (2-Pin Connector) (18 AWG)
GB = 10-inch Cable w/Deutsch Plug HD 16-3 96S (3-Pin Connector) (16 AWG)*
Circuit forms5SPDT, SPST - NO/NC SPDT, SPST - NO/NC SPDT, SPST - NO/NC SPDT, SPST - NO/NC
Life 2 million 1 million 2 million 1 million
Agency approvals
(special use switches) UL pending UL pending UL pending UL pending
Agency approvals
(other) CE CE CE pending CE pending
Field adjustability6no no yes yes
Spike dampening yes yes no no
Ingress protection7IP67 IP67 IP67 IP67
Vibration resistance 10 Hz to 2000 Hz at 15 g
20 min/sweep
10 Hz to 2000 Hz at 15 g
20 min/sweep
10 Hz to 2000 Hz at 15 g
20 min/sweep
10 Hz to 2000 Hz at 15 g
20 min/sweep
Shock resistance 500 m/sec2, 11 mSEC,
100 shocks / axis
500 m/sec2, 11 mSEC,
100 shocks / axis 500 m/sec2, 11 mSEC 500 m/sec2, 11 mSEC
Wetted part
(diaphragm) n/a n/a Kapton® (Teon® coated),
Tefzel®
Kapton® (Teon® coated),
Tefzel®
Wetted part (piston) nitrile or EPDM O-ring,
steel piston
nitrile or EPDM O-ring,
steel piston n/a n/a
Weight 0,133 g [4.7 oz] 0,133 g [4.7 oz] 0,058 kg [2.0 oz] 0,053 kg [1.9 oz]
Contacts silver / gold inlay silver gold plated gold plated
Product nish zinc plating zinc plating zinc plating zinc plating
1Set point: Point at which switch actuates or de-actuates
2Operating pressure: Maximum normal system operating pressure (above set point)
3Proof pressure: Maximum pressure that the switch can handle while it maintains set point accuracy. Intermittent spikes to this level are acceptable.
4Burst pressure: Point of complete switch failure
5SPST: Single pole, single throw. SPDT: Single pole, double throw. NO: Normally open. NC: Normally closed.
6Field adjustability only available with AA, BA, CA, and DA (SPST only) terminations.
7IP00 for AA and BA terminations.
*These connectors are designed for dual circuit (SPDT) by default. They can be used for single-circuit applications (SPNC/SPNO) by making suitable connec-
tions. Refer to wiring diagram.
**Option AB is available only for LP and LE Series.
Table 2. Specifications (continued)
5
sensing.honeywell.com
Honeywell Pressure Switches
DIMENSIONS - HIGH PRESSURE: HP SERIES, HE SERIES
Figure 1. AMP Superseal 1.5
(top view)
(bottom view)
61,64 mm
[2.427 in]
27 mm hex A/F
20,02 mm max.
[0.788 in] max.
81,66 mm
[3.215 in]
Female Connector Part Number (included): C-282105
Male Mating Connector (customer provided): C-282087
IP Rating: IP67
Figure 2. Deutsch
(top view)
61,64 mm
[2.427 in]
27 mm hex A/F
21,16 mm max.
[0.833 in] max.
(bottom view)
82,8 mm
[3.26 in]
Female Connector Part Number (included): DT04-3P
Male Mating Connector (customer provided): DT06-3S
IP Rating: IP67
Figure 3. Spade Terminal
Figure 4. Screw Terminal
(top view)
61,64 mm
[2.427 in]
27 mm hex A/F 14,43 mm
[0.568 in]
max.
76,08 mm
[2.995 in] (bottom vie
w)
(top view)
61,64 mm
[2.427 in]
27 mm hex A/F
12,65 mm
[0.498 in]
max.
74,3 mm
[2.925 in]
(bottom vie
w)
Figure 5. Cable
(top view)
61,64 mm
[2.427 in]
27 mm hex A/F
19,51 mm max.
[0.768 in] max.
81,15 mm
[3.195 in] (bottom view)
IP Rating: IP67
Figure 6. High Pressure Port Dimensions
1/2-20 UNF
+0.002
-0.003
.081
.4
33
.5
57
1/2 - 20UNF 2A
Ø 0.432
9/16-18 UNF
.088
.472
.518
9/16 - 18UNF
2A
+0.002
-0.003
Ø 0.482
3/14-16 UNF
.100
.551
.439
3/4-16UNF
2A
+0.002
-0.003
Ø 0.660
7/8-14 UNF
.112
00
90
7/8-14 UNF
+0.002
Ø 0.776
M14 × 1.5
.098`.004
.118
.4
33
Ø.740
.5
57
M14 X 1.
5
+0.002
-0.003
Ø 0.461
M18 × 1.5
.0
98`.004
.118
.551
Ø.937
.439
M18 X 1.5
+0.002
-0.003
Ø 0.618
6sensing.honeywell.com
HP Series, HE Series, LP Series, LE Series
DIMENSIONS - LOW PRESSURE: LP SERIES, LE SERIES
Port Diameter “ØD” Height “H”
R 1/2 BSPT 21,34 mm [0.840 in] 17,09 mm [0.673 in]
R 1/4 BSPT 13,46 mm [0.530 in] 13,74 mm [0.541 in]
R 1/8 BSPT 9,96 mm [0.392 in] 10,24 mm [0.403 in]
1/8-27 PTF 10,34 mm [0.407 in] 9,24 mm [0.364 in]
1/4-18 NPT 13,72 mm [0.540 in] 17,63 mm [0.694 in]
1/8-27 NPT 10,29 mm [0.405 in] 12,497 mm [0.492 in]
G 1/4 BSPP 11,1 mm [0.437 in] 11,20 mm [0.441 in]
G 1/8 BSPP 8,28 mm [0.326 in] 7,59 mm [0.299 in]
7/16-20 UNF
9,25 mm
[0.364 in] 9,09 mm [0.358 in]
9/16-18 UNF
12,24 mm
[0.482 in] 10,00 mm[0.394 in]
1/2-20 UNF
10,85 mm
[0.427 in] 9,09 mm [0.358 in]
M14 × 1.5 11,71 mm [0.461 in] 10,998 mm [0.433 in]
M12 × 1.5 9,70 mm [0.382 in] 10,998 mm [0.433 in]
M10 × 1.0 8,41 mm [0.331 in] 8,51 mm [0.335 in]
Figure 7. AMP Superseal 1.5
(bot
tom view) 58,93 mm max.
[2.32 in] max.
F
emale connector part number (included): C-282105
Male mating connector (customer provided):
C-282087
IP rating:
IP67
Figure 8. Deutsch 3-pin
(bot
tom view) 57,66 mm max.
[2.27 in] max.
F
emale connector part number (included): DT04-3P
Male mating connector (customer provided):
DT06-3S
IP rating:
IP67
Figure 9. Deutsch 2-pin
Figure 10. Wire out
(bot
tom view) 58,93 mm max.
[2.32 in] max.
F
emale connector part number (included): DT04-2P
Male mating connector (customer provided):
DT06-2S
IP rating:
IP67
(bot
tom view) 42,16 mm max.
[1.66 in] max.
IP rating:
IP67
Figure 11. Spade terminal
Figure 12. Screw terminal
(bot
tom view) 33,02 mm max.
[1.30 in] max.
(bot
tom view) 33,02 mm max.
[1.30 in] max.
Figure 13. Low Pressure Port Dimensions
HH
H
ØD
ØD
ØD
Table 3. Low Pressure Port Diameters and Heights
7
sensing.honeywell.com
Honeywell Pressure Switches
NOMENCLATURE: HIGH PRESSURE
HP
Series
R
F
Rising
factory set,
non-adjustable
Falling
factory set,
non-adjustable
Set Point
R
P
B
psig,
sealed gage
bar,
sealed gage
Pressure
Unit
P
HP Series,
HE Series
High
Pressure
Switch
C1/2-20 UNF*
* not applicable for
10.3 bar to 65,5 bar
[150 psi to 950 psi]
** not applicable for
10.3 bar to 24,1 bar
[150 psi to 350 psi]
F
G9/16-18 UNF**
M14 x 1.5**
H
F
Port Type
10,34 bar to 310,26 bar
[150 psi to 4500 psi]
Pressure
Set Point
05500
3/4-16 UNF
D
C
NSPST-NO,
silver contacts
SPST-NC,
silver contacts
SPDT-NO/NC,
silver contacts
N
Output
S
Cold-rolled
steel
Base
S
P
NPetroleum-based
hydraulic fluid
(Nitrile)
Glycol-based
fluid (EPDM)
P
Actuation/
Application
A
B
Standard
switch
With 3 shrink
sleeve
Options
A
MA
10-inch Cable w/Deutsch
DT04-2P-E005
(2-Pin Connector) (18 AWG)
CA
DA
BA
AA 1/4 in Spade
Terminals
Screw
Terminals
Deutsch DT04-3P-E005
(3-Pin Connector)
Amp Super Seal 1.5 -
282105-1
(3-Pin Connector)
FA
GA
EA 10-inch Cable, 18 AWG
(Wire Out, No Connector)
10-inch Cable w/Amp
Super Seal 1.5 - 282105-1
(3-Pin Connector) (18 AWG)*
10-inch Cable w/Deutsch
DT04-3P-E005
(3-Pin Connector) (16 AWG)*
HA
JA
AA
Connector
Type
KA
10-inch Cable w/M12x1
(Brad Harrison Micro) -
21032121306 Harting P/N
(3-Pin Connector) (18 AWG)*
10-inch Cable w/Metripack
280 Delphi 15300002
(2-Pin Connector) (18 AWG)*
10-inch Cable w/
Din43650-C
(3-Pin Connector) (18 AWG)*
LA
10-inch Cable w/Packard
Weatherpack Male Terminal -
12020827 (3-Pin Connector)
(18 AWG)
NOTE:
Pressure set point
is always five digits.
For bar, the set point
value will be multiplied
by 100 and entered
in the listing. For example,
15,45 Bar is noted as 01545.
This allows for 2 decimal
places.
For psi, the set point
value will be multiplied
by 10 and entered
in the listing. For example,
245.5 psi is noted as 02455.
This allows for 1 decimal place.
KM18 × 1.5
N7/8-14 UNF K
J
HNO, gold
inlay contacts
NC, gold
inlay contacts
SPDT(NO/NC),
gold inlay
contacts
NA
PA
RA
4-inch Cable w/Packard
2P Shroud Connector -
12010973 (2-Pin Connector)
(16 AWG)
3-inch Cable w/Packard 2P
Tower Connector -
12015792 (2-Pin Connector)
(18 AWG)
2.75-inch Cable w/Packard
2P Shroud Connector -
12010973 (2-Pin Connector)
(18 AWG)
EB
4.5-inch Cable w/Packard
Shroud Connector 12015792
(2-Pin Connector) (18 AWG)
UA
VA
TA
SA
5.5-inch Cable w/ITT
Cannon 2P Sure-Seal
Circular Connector -
SS2R-120-1804-000 (2-Pin
Connector) (18 AWG)
8.5-inch Cable w/ITT
Cannon 3P Sure-Seal
Circular Connector -
SS3R-120-8551-001 (3-Pin
Connector) (16 AWG)*
10-inch Cable - Vacuum
Impregnated w/Deutsch
DT06-3S-EP06 (3-Socket
Connector) (16 AWG)*
10-inch Cable - Vacuum
Impregnated w/Deutsch
DT04-3P-E005 (3-Pin
Connector) (16 AWG)*
YA
WA 4.5-inch Cable w/ 1/4 in
Spade Terminals 6,3 mm x
0,8 mm (16 AWG)*
6-inch Cable w/Amp
Super Seal 1.5 - 282104-1
(2-Pin Connector) (18 AWG)*
ZA
AB
BB
10-inch Cable w/Metripack
150 Delphi 12129615
(3-Pin Connector) (18 AWG)*
10-inch Cable w/Deutsch
DT06-2S-CE06 (2-Socket
Connector) (18 AWG)
Deutsch DT04-2P-E005
(2-Pin Connector)**
DB
10-inch Cable w/AMP 2,5 mm
System Series Connector
1-967402-1 (18 AWG)*
FB
GB
10-inch Cable w/Metripack
150 Delphi 12052641
(2-Pin Connector) (18 AWG)
10-inch Cable w/Deutsch
Plug HD 16-3 96S
(3-Pin Connector) (16 AWG)*
C
D
With shrink
sleeve
(plastic coating)
With shrink
sleeve
(acrylic coating)
E
F
With 1/8 watt
resistor
between terms.
304,8 mm [12 in]
total wire length
G
With conduit
sleeve
Packaging
Options
01
01 Individually
boxed units
15
20 50 individual
boxes packed in
bulk packaging
25 individual
boxes packed in
bulk packaging
25 25 units in
bulk packaging
50 50 individual
parts in
bulk packaging
V
Stainless
steel
*These connectors are designed for dual circuit (SPDT) by default.
They can be used for single-circuit applications (SPNC/SPNO) by
making suitable connections. Refer to wiring diagram.
**Option AB is available only for LP and LE Series.
For example, HPR05500PFNSPAAA01 denes a high pressure switch, rising factory set, non-adjustable set point, 550 psi set point,
psig, sealed gage pressure unit, M14 x 1.5 port type, SPST-NO silver contacts output, cold-rolled steel base, glycol-based uid (EPDM)
actuation/application, spade terminal connectors, standard switch, individually boxed units.
8sensing.honeywell.com
HP Series, HE Series, LP Series, LE Series
NOMENCLATURE: LOW PRESSURE
LP
Series
R
F
Rising
factory set,
non-adjustable
Falling
factory set,
non-adjustable
Set Point
R
P
B
psig,
sealed gage
bar,
sealed gage
Pressure
Unit
P
LP Series,
LE Series
Low
Pressure
Switch C1/2-20 UNF
E
FM14 x 1.5
M12 x 1.5
G
F
Port Type
0,24 bar to 10,34 bar
[3.5 psi to 150 psi]
Pressure
Set Point
00550
9/16-18 UNF
Y
M
PSPST-NO,
gold-plated contacts
SPST-NC,
gold-plated contacts
SPDT-NO/NC,
gold-plated contacts
P
Output
B
Brass
Base
VK
Actuation/
Application
A
B
Standard
switch
With 3 shrink
sleeve
Options
A
NOTE:
Pressure set point
is always five digits.
For bar, the set point
value will be multiplied
by 100 and entered
in the listing. For example,
15,45 Bar is noted as
01545. This allows for
2 decimal places.
For psi, the set point
value will be multiplied
by 10 and entered
in the listing. For example,
245.5 psi is noted as 02455.
This allows for 1 decimal place.
JG1/8 BSPP
M7/16-20 UNF
C
D
With shrink
sleeve
(plastic coating)
With shrink
sleeve
(acrylic coating)
E
F
With 1/8 watt
resistor
between terms.
304,8 mm [12 in]
total wire length
G
With conduit
sleeve
Packaging
Options
01
01 Individually
boxed units
15
20 150 units in
bulk packaging
25 individual
boxes packed in
bulk packaging
T
C
Rising,
field
adjustable*
Falling,
field
adjustable*
* Field adjustable option is only
available for:
1. Blade and screw terminations
2. Deutsch DT04-3P
(SPDT, SPNO, SPNC)
3. Amp Superseal 1.5 (3-pin)
(SPNO & SPNC)
Mbar,
true gage
Tpsig,
true gage
A1/4-18 NPT
B1/8-27 NPT
D1/8-27 PTF
VR1/2 BSPT
ZR1/4 BSPT
RR1/8 BSPT
TM10 × 1.0
YG1/4 BSPP
N
Cold-rolled
steel H
K
Kapton diaphragm
(Teflon coated),
Nitrile O-ring1
Kapton diaphragm
(Teflon coated),
EPDM O-ring2
U
TTefzel diaphragm,
Nitrile O-ring3
Tefzel diaphragm,
EPDM O-ring4
1 Air, Petroleum-based
hydraulic fluid, engine oil
2 Glycol-based fluid
3 For high temperature
fluid media
4 For high temperature
fluid media, glycol-based
fluid
R
With port neck
o-ring
H3/4-16 UNF
V
Stainless
steel
AA
Connector
Type
MA
10-inch Cable w/Deutsch
DT04-2P-E005
(2-Pin Connector) (18 AWG)
CA
DA
BA
AA 1/4 in Spade
Terminals
Screw
Terminals
Deutsch DT04-3P-E005
(3-Pin Connector)
Amp Super Seal 1.5 -
282105-1
(3-Pin Connector)
FA
GA
EA 10-inch Cable, 18 AWG
(Wire Out, No Connector)
10-inch Cable w/Amp
Super Seal 1.5 - 282105-1
(3-Pin Connector) (18 AWG)*
10-inch Cable w/Deutsch
DT04-3P-E005
(3-Pin Connector) (16 AWG)*
HA
JA
KA
10-inch Cable w/M12x1
(Brad Harrison Micro) -
21032121306 Harting P/N
(3-Pin Connector) (18 AWG)*
10-inch Cable w/Metripack
280 Delphi 15300002
(2-Pin Connector) (18 AWG)*
10-inch Cable w/
Din43650-C
(3-Pin Connector) (18 AWG)*
LA
10-inch Cable w/Packard
Weatherpack Male Terminal -
12020827 (3-Pin Connector)
(18 AWG)
NA
PA
RA
4-inch Cable w/Packard
2P Shroud Connector -
12010973 (2-Pin Connector)
(16 AWG)
3-inch Cable w/Packard 2P
Tower Connector -
12015792 (2-Pin Connector)
(18 AWG)
2.75-inch Cable w/Packard
2P Shroud Connector -
12010973 (2-Pin Connector)
(18 AWG)
EB
4.5-inch Cable w/Packard
Shroud Connector 12015792
(2-Pin Connector) (18 AWG)
UA
VA
TA
SA
5.5-inch Cable w/ITT
Cannon 2P Sure-Seal
Circular Connector -
SS2R-120-1804-000 (2-Pin
Connector) (18 AWG)
8.5-inch Cable w/ITT
Cannon 3P Sure-Seal
Circular Connector -
SS3R-120-8551-001 (3-Pin
Connector) (16 AWG)*
10-inch Cable - Vacuum
Impregnated w/Deutsch
DT06-3S-EP06 (3-Socket
Connector) (16 AWG)*
10-inch Cable - Vacuum
Impregnated w/Deutsch
DT04-3P-E005 (3-Pin
Connector) (16 AWG)*
YA
WA 4.5-inch Cable w/ 1/4 in
Spade Terminals 6,3 mm x
0,8 mm (16 AWG)*
6-inch Cable w/Amp
Super Seal 1.5 - 282104-1
(2-Pin Connector) (18 AWG)*
ZA
AB
BB
10-inch Cable w/Metripack
150 Delphi 12129615
(3-Pin Connector) (18 AWG)*
10-inch Cable w/Deutsch
DT06-2S-CE06 (2-Socket
Connector) (18 AWG)
Deutsch DT04-2P-E005
(2-Pin Connector)**
DB
10-inch Cable w/AMP 2,5 mm
System Series Connector
1-967402-1 (18 AWG)*
FB
GB
10-inch Cable w/Metripack
150 Delphi 12052641
(2-Pin Connector) (18 AWG)
10-inch Cable w/Deutsch
Plug HD 16-3 96S
(3-Pin Connector) (16 AWG)*
*These connectors are designed for dual circuit (SPDT) by default.
They can be used for single-circuit applications (SPNC/SPNO) by
making suitable connections. Refer to wiring diagram.
**Option AB is available only for LP and LE Series.
Blade and screw electrical
terminations are available
with only the the true gage
option.
True gage option is available
only up to 20 psig set
point for integral connectors
and wire out electrical
terminations.
For example, LPR00550PFPVKAAA01 denes a low pressure switch, rising factory set, non-adjustable set point, 55 psi set point, psig,
sealed gage pressure unit, M14 x 1.5 port type, SPST-NO gold-plated contacts output, stainless steel base, Kapton® diaphragm (Teon®
coated), Nitrile O-ring actuation/application, spade terminal connectors, standard switch, individually boxed units.
9
sensing.honeywell.com
Honeywell Pressure Switches
ADDITIONAL INFORMATION
The following associated literature is available on the Sensing and
Control web site at sensing.honeywell.com:
Product installation instructions
Product range guide
Product application-specific information
WARNING
PERSONAL INJURY
DO NOT USE these products as safety or emergency stop
devices or in any other application where failure of the
product could result in personal injury.
Failure to comply with these instructions could result in
death or serious injury.
WARNING
MISUSE OF DOCUMENTATION
The information presented in this product sheet is for
reference only. Do not use this document as a product
installation guide.
Complete installation, operation, and maintenance
information is provided in the instructions supplied with
each product.
Failure to comply with these instructions could result in
death or serious injury.
WARRANTY/REMEDY
Honeywell warrants goods of its manufacture as being free of
defective materials and faulty workmanship. Honeywell’s standard
product warranty applies unless agreed to otherwise by Honeywell
in writing; please refer to your order acknowledgement or consult
your local sales office for specific warranty details. If warranted
goods are returned to Honeywell during the period of coverage,
Honeywell will repair or replace, at its option, without charge those
items it finds defective. The foregoing is buyer’s sole remedy
and is in lieu of all other warranties, expressed or implied,
including those of merchantability and fitness for a particu-
lar purpose. In no event shall Honeywell be liable for conse-
quential, special, or indirect damages.
While we provide application assistance personally, through our
literature and the Honeywell website, it is up to the customer to
determine the suitability of the product in the application.
Specifications may change without notice. The information we
supply is believed to be accurate and reliable as of this printing.
However, we assume no responsibility for its use.
50094081-3-EN IL50 GLO
May 2014
Copyright © 2014 Honeywell International Inc. All rights reserved.
® DuPont™, Teflon®, Tefzel®, and Kapton® are trademarks or registered trademarks of E.I. du Pont de Nemours and Company.
Sensing and Control
Honeywell
1985 Douglas Drive North
Golden Valley, MN 55422
honeywell.com
Find out more
Honeywell serves its customers
through a worldwide network
of sales offices, representatives
and distributors. For application
assistance, current specifications,
pricing or name of the nearest
Authorized Distributor, contact
your local sales office.
To learn more about Honeywell’s
sensing and control products,
call +1-815-235-6847 or
1-800-537-6945,
visit sensing.honeywell.com,
or e-mail inquiries to
info.sc@honeywell.com