Specification Control Drawing
Tyco Electronics Corporation
300 Constitutional Drive
Menlo Park, CA 94025 USA
Title:
AlteraMicroFit
Heat - Shrinkable Tubing
Tyco Electronics reserves the right to amend this drawing at any
time. Users should evaluate the suitability of the product for their
application
Document No :
Altera MicroFit
Cage Code:
06090
Scale:
None Size:
A Rev. Date:
17-Sept-01
Rev.:
B
Sheet:
1 of 2
If this document is printed it becomes uncontrolled. Check for the latest revision.
AlteraMicroFit
Heat - Shrinkable Tubing
This specification covers the requirements for two types of single wall, electrical insulating, extruded
tubing whose diameters will reduce to a predetermined size upon application of heat in excess of 175° C
(347° F) for MT1000 and 140° C (284° F) for MT2000.
The tubing shall be homogenous and essentially free from flaws, defects, pinholes, seams, cracks or
inclusions.
The tubing is fabricated from materials, which meet the requirements of U.S. Pharmacopeia Class VI
Plastics. Color shall be translucent or black unless otherwise specified.
Table 1: Dimensions inches (mm)
As Supplied Recovered
Size Expanded I.D.
Minimum (D)
Recovered I.D.
Maximum (d)
Recovered Wall
Maximum (W)
MFT-*- No.1-** .014 (.356) .007 (.178) .005 (.127)
MFT-*- No.2-** .024 (.610) .012 (.305) .006 (.152)
MFT-*- No.33-** .045 (1.143) .017 (.432) .007 (.118)
MFT-*- No.65-** .025 (.635) .010 (.254) .013 (.330)
* = material MT1000 or MT2000
** = color
MT1000 is semi-rigid polyvinylidene material.
MT2000 is medical grade polyolefin material.
Rev. Date:
17-Sept-01
Rev.:
B
Document No.
Altera MicroFit
Sheet:
2 of 2
If this document is printed it becomes uncontrolled. Check for the latest revision.
MT1000
Property Unit Requirement Test Method
Physical
* Dimensions Inches (mm) In accordance with Table 1 ASTM D 2671
Tensile Strength PSI (MPa) 5000 minimum (34.5) ASTM D 2671,
Ultimate Elongation Percent 150 minimum 2"/ minute
Secant Modulus (as supplied) PSI (MPa) 1x105 minimum (690) ASTM D 2671
Electrical
Dielectric Strength
Volts/mil
Volts/mm
800 minimum (31,500)
ASTM D 2671
Dielectric Withstand
3000V, 60 Hz
sec
60 minimum
ASTM D 2671
Heavy Metals Analysis
Cadmium
Mercury
Lead
Bismuth
Antimony
ppm 1 maximum
(total of all metals)
USP XXII
Physicochemical
Tests-Plastics
(Note 1)
MT2000
Property Unit Requirement Test Method
Physical
* Dimensions Inches (mm) In accordance with Table 1 ASTM D 2671
* Tensile Strength PSI (MPa) 3000 minimum (20.7) ASTM D 2671,
* Ultimate Elongation Percent 200 minimum 2"/ minute
Secant Modulus (as supplied) PSI (MPa) 5x104 minimum (344) ASTM D 2671
Electrical
Dielectric Strength
Volts/mil
Volts/mm
1000 minimum (39,360)
ASTM D 2671
Dielectric Withstand
3000V, 60 Hz
sec
60 minimum
ASTM D 2671
Heavy Metals Analysis
Cadmium
Mercury
Lead
Bismuth
Antimony
ppm 1 maximum
(total of all metals)
USP XXII
Physicochemical
Tests-Plastics
(Note 1)
* Denotes lot acceptance test
Note 1: Sample preparation and extraction is per USP XXII. Metals analysis may be colorimetric as