Inches
mm
.125
3.18
.250
6.35
1.25
31.75
1.312
33.32
1.500
38.10
MIL-DTL-83413/8E
10 June
2015
SUPERSEDING
MIL-DTL-83413/8D
w/Amendment 1
30 July
2014
DETAIL SPECIFICATION
SHEET
CONNECTORS AND ASSEMBLIES, ELECTRICAL,
AIRCRAFT
GROUNDING: TYPE IV JUMPER CABLE ASSEMBLY, LEAD,
ELECTRICAL
This specification is approved for use
by
all Departments and Agencies of the Department of
Defense.
The requirements for acquiring the product described herein shall consist of this specification sheet and
MIL-DTL-83413.
NOTES:
1. Dimensions are in inches.
2. Metric equivalents are given for information only.
3. Resistance readings to be taken at the junction of terminal barrels and tongues.
4. For assembly types I, J, K, and L where chafe guard/ identification label is used instead of the ID
band, chafe guard must cover exposed cable length with a maximum gap of 0.120 inch between
chafe guard end and start of terminal barrel insulation.
FIGURE 1. Jumper cable
assembly.
AMSC N/A FSC 6150
INCH-POUND
Source: http://assist.dla.mil -- Downloaded: 2021-02-08T11:20ZCheck the source to verify that this is the current version before use.
MIL-DTL-83413/8E
2
TABLE I. Jumper assembly types and characteristics.
Jumper
assembly
type
Construc-
tion type
terminal
material
Wire
size
(see
table
II)
Available lug
sizes (see
tables III, IV,
V, VI, VII,
VIII, VII II, )
Available
cable
length,
see “L” or
“P”
dimensions
on
figure 1
Lightning
tested
Fuel
Compat-
Ible 1/
Method of
attaching
terminals
Color
of ID
band
or ID
Cha
fe
Guard
Supersedes
and referenc
e
only for types
I, J, K and L
A
Bonding
12
A thru J
002-999
No
No
Crimp
No
band
MS25083-2
B
Current
return
8
K,L,M,N,T,U
002-999
No
No
Crimp
No
band
MS25083-4
C 2/ Bonding Aluminum 10 O,P,Q,R,S
(aluminum
only)
003-999
No Yes Brazed 4/ Clear MS25083-1
and -7
D 3/ Quick
disconnect Copper 12 A,B,C,D,E,
F,G
003-999
No
No Crimp No
band MS25083-3
E 3/
Short end
of quick
disconnect
12
A,B,C,D,E,
F,G
Fixed
length
No
No
Crimp
No
band
MS25083-3S
F 3/ Long end
of
quick
disconnect
Copper 12 A,B,C,D,E,
F,G 002-999
No
No Crimp No
band MS25083-3P
G Bonding Copper 12 A thru J 003-999
Yes
No Crimp Yellow MS25083-5
H Current
return
Copper 8 K,L,M,N,T,U 003-999
Yes
No Crimp Yellow MS25083-6
I 6/
Static
Charge
Bonding
14
A,B,C,D,E,
F,G
003-999
No
No
Crimp
ID
Black
Chafe
Guard
SS7039-7
J 5/ Static
Charge
Bonding
Steel 1/16 A,B,C,D,E,
F,G 003-999 No No Crimp ID
Black
Chafe
Guard
SS7039-2
K 5/ Bonding Steel 3/32 A,B,C,D,E,
F,G 003-999 No No Crimp ID
Black
Chafe
Guard
SS7039-3
L 5/ Bonding Steel 1/8 A,B,C,D 003-999 No No Crimp ID
Black
Chafe
Guard
SS7039-4
1/ Only fuel compatible jumper assemblies may be used within fuel tank and cells.
2/ Do not use outside fuel tanks and cells.
3/ Inactive for Air Force Airborne use after 9 December 1963.
Source: http://assist.dla.mil -- Downloaded: 2021-02-08T11:20ZCheck the source to verify that this is the current version before use.
MIL-DTL-83413/8E
3
TABLE I. Jumper assembly types and characteristics. Continued.
4/ Dip braze terminals in accordance with AWS-C3.7 Specification for Aluminum Brazing. A coating
is
not required on interior strands of the cable, chemical conversion coating in accordance with MIL-DTL-
5541, class 3 shall be applied after brazing. Inert gas welding using aluminum based solder or other
means of termination may be used only if approved by the qualifying activity. Aluminum
terminals may be crimped to the cable to facilitate dip brazing. Over crimping shall be avoided.
5/ Bonding jumper types J, K, and L are intended for use on aircraft structures where they are
subjected to continuous and/ or excessive vibrations.
6/ Static charge bonding types I and J are used for static charge bonding applications. Static charge
bonding types I and J shall not be used for lightning protection bonding, which requires conductor
sizes of 12 AWG or larger.
TABLE II. Wire characteristics by jumper assembly type.
Jumper
assembly
type
Material
Stranding
no. x
AWG
Wire
size
Assembly 1/
resistance
(max-ohms)
Tensile
strength
(min-lb)
Crimp tool requirem ents
Crimping tools 2/ Crimping dies
A, G
Copper
(7 x 37) x
36
12
.00016xL
+ .00034
110
M22520/5-01 3/ or
M22520/24-01
M22520/5-100
B, H
Copper
(7 x 95) x
36
8
.0006xL
+ .00016
225
SAE-AS5259/1
SAE-AS5259/1
3/
C Aluminum
37 x
0.0167
inch
10
.00042xL
+ .00110
75 Not applicable Not applicable
D Copper (7 x 37) x
36 12
.00016xL
+ .00034
5 to
28
4/
M22520/5-01
M22520/24-01 M22520/5-100
E Copper (7 x 37) x
36 12 .00057
110 M22520/5-01
M22520/24-01 M22520/5-100
F
Copper
(7 x 37) x
36
12
.00016xL
+ .00034
110
M22520/5-01
M22520/24-01
M22520/5-100
I 5/
Copper
(7 x 24) x
36
14
.00021xL
+.00043 Ω
70
/6 /6
J 5/ Steel (7 x 19) 1/16
.08333xL
+.00043 Ω
70
/6 /6
K 5/
Steel
(7 x 19)
3/32
. 08333xL
+.00043 Ω
110
/6 /6
L 5/
Steel
(7 x 19)
1/8
.08333xL
+.00043 Ω
225
/6 /6
1/ Where L = length of the cable assembly in inches. Example: For a 24 inch type A assembly, assembly
resistance = .00016 ohm/inch x 24 inches + .00034 = .00418 ohms (max).
2/ Alternate crimping tools which use the specified dies of this table or qualified class II copper terminal
lugs in accordance with SAE-AS7928/1 (crimped with the tools and dies used t o obtain the class II
terminal lug approval), may be used to facilitate high volume production of copper jumpers. However,
either of these options must be pre-approved by the qualifying activity before qualification tests are
initiated on samples produced using these termination options.
Source: http://assist.dla.mil -- Downloaded: 2021-02-08T11:20ZCheck the source to verify that this is the current version before use.
MIL-DTL-83413/8E
4
TABLE II. W ire characteristics by jumper assembly type. – Continued.
3/ Application: M22520/5-01 and /5-100 for use on insulated terminals. M22520/24-01 and SAE-AS5259/1
for use on uninsulated terminals.
4/ Tensile strength for D jumper assemblies is 5 to 28 lbs, however for the separate assembly ends: E
=
110 lbs and F=110 lbs.
5/ Notes 2/, 3/, & 4/ are not applicable to Jumper assembly types I, J, K, and L.
6/ See crimp tool manuf acturer requirements.
TABLE III. Available lug
sizes.
A,D,E,F & G type jumper assembly. 1/ 2/ 3/ 4/
8/
Code letter lug size
designation
For stud
size
12 AWG Copper
terminals
(All types except type C, I, J, K, &
L)
SAE-AS25036
Insulated
SAE-AS20659
Un-insulated
A
.138
(3.51)
-111
F
.138
(3.51)
-165
I
.164
(4.17)
-156
B
.190
(4.83)
-112
G
.190
(4.83)
-105
C
.250
(6.35)
-157
D
.312
(7.92)
-113
H
6/
.312
(7.92)
-106
E
.375
(9.53)
-114 5/
J
7/
.375
(9.53)
-128
1/ Dimensions are in inches. Metric equivalents are given for information only.
2/ Unless otherwise specified, tolerance is +.005.
3/ Resistance readings to be taken at the junction of terminal barrels and tongues.
4/ Lightning current tests applicable to type G and H assemblies only.
5/ Size #10, #12, & #14 AWG wire only.
6/ Lug size designators D & H correspond to lug size D in Rev B, but were broken out
separately for clarification.
7/ Lug size designators E & J correspond to lug size E in Rev B, but were broken out
separately for clarification.
8/ For supersession information see table X.
Source: http://assist.dla.mil -- Downloaded: 2021-02-08T11:20ZCheck the source to verify that this is the current version before use.
MIL-DTL-83413/8E
5
TABLE IV. Available lug
sizes.
B & H type jumper assembly. 1/ 2/ 3/ 4/
8/
Code letter lug size
designation
For stud
size
8 AWG Copper terminals (All
types
except type C, I, J, K, &
L)
SAE-AS25036
Insulated
SAE-AS20659
Uninsulated
T
.250
(6.35)
-116
U
.250
(6.35)
-141
K
6/
.312
(7.92)
-117 5/
L
6/
.312
(7.92)
-108
5/
M
7/
.375
(9.53)
-118
N
7/
.375
(9.53)
-129 5/
W
.164
(4.17)
-140
V
.190
(4.83)
-107
Z
.190
(4.83)
-115
1/ Dimensions are in inches. Metric equivalents are given for information only.
2/ Unless otherwise specified, tolerance is +.005.
3/ Resistance readings to be taken at the junction of terminal barrels and tongues.
4/ Lightning current tests applicable to type G and H assemblies only.
5/ Size #8 AWG wire only.
6/ Lug size designators K & L correspond to lug size D in Rev B, but were broken out
separately for clarification.
7/ Lug size designators M & N correspond to lug size E in Rev B, but were broken out
separately for clarification.
8/ For supersession information see table XI.
Source: http://assist.dla.mil -- Downloaded: 2021-02-08T11:20ZCheck the source to verify that this is the current version before use.
MIL-DTL-83413/8E
6
TABLE V. Available lug
sizes.
C type jumper assembly. 1/ 2/ 3/
6/
Code
letter
lug
size
designation
For
stud
size
Stud
Hole
ID
M
min
Aluminum terminal
W Y Z
max
O .138 (3.51) .152 (3.86) .218 (5.54) .406 (10.31)
.083
1.172 (29.77)
.142 (3.61)
P .190 (4.83) .203 (5.16) .250 (6.35)
.193 (4.90)
.313 (7.95) (2.11)
.037
(0.94)
Q .250 (6.35) .285 (7.24) .281 (7.14) .540 (13.72) 1.300 (33.02)
.260 (6.60) .450 (11.43)
R 4/ .312 (7.92) .343 (8.71) .329 (8.36) .741 (18.82)
.090
1.390 (35.31)
.320 (8.13)
S 5/ .375 (9.53) .385 (9.78) .343 (8.71)
.410 (10.41)
.531 (13.49) (2.29)
.038
(0.97)
1.626 (41.30)
1/ Dimensions are in inches. Metric equivalents are given for information only.
2/ Unless otherwise specified, tolerance is +.005.
3/ Resistance readings to be taken at the junction of terminal barrels and tongues.
4/ Lug size designators R correspond to lug size D in Rev B, but were broken out
separately for clarification.
5/ Lug size designators S correspond to lug size E in Rev B, but were broken out
separately for clarification.
6/ For supersession information see table XII.
Source: http://assist.dla.mil -- Downloaded: 2021-02-08T11:20ZCheck the source to verify that this is the current version before use.
MIL-DTL-83413/8E
7
TABLE VI. Available lug
sizes.
I type jumper assembly. 1/ 2/ 3/ 4/ 5/
6/
Code letter lug size
designation
For stud size
12 AWG 6/ Copper
terminals
(type I jumper
assembly)
SAE-AS7928/1
Insulated
A
.138
(3.51)
-56
B
.164
(4.17)
-57
C
.190
(4.83)
-58
D
.250
(6.35)
-59
E
.312
(7.92)
-60
F
.375
(9.53)
-61
G
.500
(12.70)
-62
1/ Dimensions are in inches. Metric equivalents are given for information only.
2/ Unless otherwise specified, tolerance is ±.005.
3/ Resistance readings to be taken at the junction of terminal barrels and tongues.
4/ Lightning current tests applicable to type G and H assemblies only.
5/ Size 14 AWG wire only.
6/ Wire diameter slightly larger than concentric lay AWG due to rope lay construction. Terminal
lug size have been selected accordingly.
Source: http://assist.dla.mil -- Downloaded: 2021-02-08T11:20ZCheck the source to verify that this is the current version before use.
8
MIL-DTL-83413/8E
TABLE VII. Available lug
sizes.
J type jumper assembly. 1/ 2/ 3/ 4/
5/
Code letter lug size designation
For stud size
14 AWG Copper terminals
(type J jumper assembly)
SAE-AS7928/1
Insulated
A
.138
(3.51)
-49
B
.164
(4.17)
-50
C
.190
(4.83)
-51
D
.250
(6.35)
-52
E
.312
(7.92)
-53
F
.375
(9.53)
-54
G
.500
(12.70)
-55
1/ Dimensions are in inches. Metric equivalents are given for information only.
2/ Unless otherwise specified, tolerance is ±.005.
3/ Resistance readings to be taken at the junction of terminal barrels and tongues.
4/ Lightning current tests applicable to type G and H assemblies only.
5/ Size 1/16 steel wire only.
Source: http://assist.dla.mil -- Downloaded: 2021-02-08T11:20ZCheck the source to verify that this is the current version before use.
9
MIL-DTL-83413/8E
TABLE VIII. Available lug
sizes.
K type jumper assembly. 1/ 2/ 3/ 4/ 5/
6/
Code letter lug size
designation
For stud
size
10 AWG 6/ Copper terminals
(type K jumper assembly)
SAE-AS7928/1
Insulated
A
.138
(3.51)
-63
B
.164
(4.17)
-64
C
.190
(4.83)
-65
D
.250
(6.35)
-66
E
.312
(7.92)
-67
F
.375
(9.53)
-68
G
.500
(12.70)
-69
1/ Dimensions are in inches. Metric equivalents are given for information only.
2/ Unless otherwise specified, tolerance is ±.005.
3/ Resistance readings to be taken at the junction of terminal barrels and tongues.
4/ Lightning current tests applicable to type G and H assemblies only.
5/ Size 3/32 steel wire only.
6/ Wire diameter slightly larger than concentric lay AWG due to rope lay construction. Terminal lug size
have been selected accordingly.
Source: http://assist.dla.mil -- Downloaded: 2021-02-08T11:20ZCheck the source to verify that this is the current version before use.
10
MIL-DTL-83413/8E
TABLE VIIII. Available lug
sizes.
L type jumper assembly. 1/ 2/ 3/ 4/ 5/
6/
Code letter lug size
designation
For stud size
8 AWG 6/ Copper
terminals
(type L jumper
assembly)
SAE-AS25036
Insulated
A
.190
(4.83)
-115
B
.250
(6.35)
-116
C
.312
(7.92)
-117
D
.375
(9.53)
-118
1/ Dimensions are in inches. Metric equivalents are given for information only.
2/ Unless otherwise specified, tolerance is ±.005.
3/ Resistance readings to be taken at the junction of terminal barrels and tongues.
4/ Lightning current tests applicable to type G and H assemblies only.
5/ Size 1/8 steel wire only.
6/ Wire diameter slightly larger than concentric lay AWG due to rope lay construction. Terminal lug size
have been selected accordingly.
Source: http://assist.dla.mil -- Downloaded: 2021-02-08T11:20ZCheck the source to verify that this is the current version before use.
11
MIL-DTL-83413/8E
REQUIREMENTS:
Material:
For jumper types A, D, E, F, and G: Soft or drawn and annealed tin coated copper wire per
ASTM- B172. Rope-lay-bunched member stranding consisting of 7 bunches of 37 individual
strands of 36 AWG equivalent solid copper wire (259 individual wire strands with total approximate
circular mill area 6475 with 12 AWG total equivalent).
For jumper type I: Soft or drawn and annealed tin coated copper wire per ASTM- B172. Rope-lay-
bunched member stranding consisting of 7 bunches of 24 individual strands of 36 AWG
equivalent solid copper wire (168 individual wire strands with total approximate circular mill area
4200 with 14 AWG total equivalent).
Aluminum wire (type C assembly): Size 10, 37 strands of 0.0167 inch, electrical grade,
aluminum alloy, 1350 strands in accordance with ASTM-B230/B230M, concentric stranded,
length of lay (pitch) .75 to 1.25 inch.
Jumper types B and H: Soft or drawn and annealed. Tin coated copper wire per ASTM-B172.
Rope-lay-bunched member stranding consisting of 7 bunches of 95 individual strands of 36 AWG
equivalent solid copper wire (665 individual wire strands with total approximate circular mill area
16625 with 8 AWG total equivalent).
For jumper types I, J, and K: Flexible, corrosion resistant steel wire rope, type I, composition B,
per MIL-DTL-83420/2, construction type 7 x 19 rope-lay-bunched member stranding consisting of
7 bunches of 19 individual strands. (133 individual wire strands total).
Coupler (assembly types D”, “E”, and “Fonly): In accordance with MIL-DTL-6852.
Identification band (types C, G, and H only): Polyolefin, heat shrinkable in accordance with SAE-AMS-
DTL-23053/5. Color specified in table I.
Chafe guard/ Identification label (types I and J only): Heat shrinkable electrical i nsulation tubin g per
SAE-AMS-DTL-23053/5, “Insulation S l eeving, Electrical, Heat Shrinkable, P ol yolefin, Flexible, CLASS I,
color black, .125" I.D. size.
Chafe guard/ Identification label (type K only): Heat shrinkable electrical insulation tubing Per
SAE-AMS- DTL-23053/5, Insulation Sleeving, Electrical, Heat Shrinkable, Polyolefin, Flexible, CLASS I,
color black,.187" I.D. size.
Chafe guard/ Identification label (type L only): Heat shrinkable electrical insulation tubing Per
SAE-AMS-DTL-23053/5, Insulation Sleeving, Electrical, Heat Shrinkable, Polyolefin, Flexible, CLASS I,
color black,.250" I.D. size.
Assembly resistance: See table II.
Tensile strength: See table II. Perform after the flexibility test in accordance with MIL-DTL-83413 group
II qualification sequence. Omit assembly resistance as a tensile strength post test.
Crimping tools and crimping dies: See table II.
Source: http://assist.dla.mil -- Downloaded: 2021-02-08T11:20ZCheck the source to verify that this is the current version before use.
12
MIL-DTL-83413/8E
Marking (types C, G, and H only): Part or Identifying Number (PIN) shall be marked on the identification
band. If the identification band is too short to accommodate the entire PIN on a single line, the PIN may
be put on two lines or both sides of the identification band. Assembly type C” parts shall be marked with
an ink or fluid which is compatible with fuel. Assembly type I, J, K, and L” parts shall be marked
with
white
lettering in ink or fluid which is compatible with fuel.
Salt spray: 48 hours in accordance with test procedure EIA/ECA-364-26.
Salt spray: Not applicable to types J, K, and L.
Altitude-low temperature: Not applicable.
Dust: Not applicable.
Ozone exposure: Not applicable.
Lightning current: Not applicable to types A, B, C, D, E, F, I, J, K, and L.
Humidity: Not applicable to types J, K, and L.
Temperature cycling: Not applicable to types J, K, and L.
Dimensions and configuration: See figure 2.
Flexibility: For type “C” aluminum assemblies, change the MIL-DTL-83413 test to the following: Twist
and flex: prior to the tensile strength test of MIL-DTL-83413.
Test No. 1 – Twist test 2 half twists (360º) in a direction to tighten the wire weave. This is
for clarification and to accommodate the short 3 inch C type jumper.
Test No. 2 – Flex 20 times.
NOTE: For copper assemblies the flexibility test in accordance with MIL-DTL-83413 shall be
performed at a rate of 30 -65 cycles/minute.
FIGURE 2. Twist and flex
test.
Qualification required: The activity responsible for the qualified products list for this specification sheet is
the DLA Land and Maritime, Columbus, DLA Land and Maritim e-VQ, P.O. Box 3990, Columbus, Ohio
43218-3990.
Source: http://assist.dla.mil -- Downloaded: 2021-02-08T11:20ZCheck the source to verify that this is the current version before use.
13
MIL-DTL-83413/8E
TABLE X. Supersession table for the A, D, E, F & G type jumper assemblies.
Superseded LUG Code (Rev B)
Preferred LUG Code
A
A
F
F
I
I
B
B
G
G
C
C
D
D
D
H
E
E
E
J
TABLE XI. Supersession
table.
B & H type jumper
assembly.
Superseded LUG Code (Rev B)
Preferred LUG Code
D
K
D
L
E
M
E
N
----
T
(NEW)
----
U
(NEW)
TABLE XII. Supersession
table.
C type jumper
assembly.
Superseded LUG Code (Rev B)
Preferred LUG Code
A
O
B
P
C
Q
D
R
E
S
F
No replacement 1/
G
No replacement 1/
1/ AS20659 is copper, uninsulated. This jumper is aluminum.
Source: http://assist.dla.mil -- Downloaded: 2021-02-08T11:20ZCheck the source to verify that this is the current version before use.
14
MIL-DTL-83413/8E
Example of PIN: M83413/8-E00AE
M 83413/ 8 - E 00 AE
Letters designating lug size for specific end (left
or right). In cases where there is a single
termination (jumper types E and F), the second
letter shall be “X”. See tables III through V for
available lug sizes.
Three digits designating cable length in inches.
Length for type E shall be 00. See table I for
available cable lengths.
Jumper assembly type as specified in Table I.
Specification sheet number
General specification number
M
prefix
Changes from previous issue. The margins of this specification are marked with vertical lines to indicate
where changes from the previous issue were made. This was done as a convenience only and the
Government assumes no liability whatsoever for any inaccuracies in these notations. Bidders and
contractors are cautioned to evaluate the requirements of this document based on the entire content
irrespective of the marginal notations and relationship to the previous issue.
Referenced documents. In addition to MIL-DTL-83413, this document references the following:
AWS-C3.7
MIL-DTL-5541
SAE-AS5259/1
SAE-AS7928/1
SAE-AS25036
SAE-AS20659
ASTM-B172
ASTM-B230/B230M
MIL-DTL-83420/2
MIL-DTL-6852
SAE-AMS-DTL-23053/5
EIA/ECA-364-26
Source: http://assist.dla.mil -- Downloaded: 2021-02-08T11:20ZCheck the source to verify that this is the current version before use.
15
MIL-DTL-83413/8E
CONCLUDING
MATERIAL
Custodians: Preparing activity:
Army - AV DLA - CC
Navy - AS
Air Force - 85 (Project 6150-2015-001)
DLA - CC
Review activities:
Army - AR, CR, CR4, MI
Navy - MC
Air Force - 71, 99
DLA -GS
NOTE: The activities listed above were interested in this document as of this document. Since
organizations and responsibilities can change, you should verify the currency of the information above
using the ASSIST Online database at https://assist.dla.mil.
Source: http://assist.dla.mil -- Downloaded: 2021-02-08T11:20ZCheck the source to verify that this is the current version before use.