REQUIREMENTS:
Material:
For jumper types A, D, E, F, and G: Soft or drawn and annealed tin coated copper wire per
ASTM- B172. Rope-lay-bunched member stranding consisting of 7 bunches of 37 individual
strands of 36 AWG equivalent solid copper wire (259 individual wire strands with total approximate
circular mill area 6475 with 12 AWG total equivalent).
For jumper type I: Soft or drawn and annealed tin coated copper wire per ASTM- B172. Rope-lay-
bunched member stranding consisting of 7 bunches of 24 individual strands of 36 AWG
equivalent solid copper wire (168 individual wire strands with total approximate circular mill area
4200 with 14 AWG total equivalent).
Aluminum wire (type C assembly): Size 10, 37 strands of 0.0167 inch, electrical grade,
aluminum alloy, 1350 strands in accordance with ASTM-B230/B230M, concentric stranded,
length of lay (pitch) .75 to 1.25 inch.
Jumper types B and H: Soft or drawn and annealed. Tin coated copper wire per ASTM-B172.
Rope-lay-bunched member stranding consisting of 7 bunches of 95 individual strands of 36 AWG
equivalent solid copper wire (665 individual wire strands with total approximate circular mill area
16625 with 8 AWG total equivalent).
For jumper types I, J, and K: Flexible, corrosion resistant steel wire rope, type I, composition B,
per MIL-DTL-83420/2, construction type 7 x 19 rope-lay-bunched member stranding consisting of
7 bunches of 19 individual strands. (133 individual wire strands total).
Coupler (assembly types “D”, “E”, and “F” only): In accordance with MIL-DTL-6852.
Identification band (types C, G, and H only): Polyolefin, heat shrinkable in accordance with SAE-AMS-
DTL-23053/5. Color specified in table I.
Chafe guard/ Identification label (types I and J only): Heat shrinkable electrical i nsulation tubin g per
SAE-AMS-DTL-23053/5, “Insulation S l eeving, Electrical, Heat Shrinkable, P ol yolefin, Flexible, CLASS I,
color black, .125" I.D. size.
Chafe guard/ Identification label (type K only): Heat shrinkable electrical insulation tubing Per
SAE-AMS- DTL-23053/5, “Insulation Sleeving, Electrical, Heat Shrinkable, Polyolefin, Flexible, CLASS I,
color black,.187" I.D. size.
Chafe guard/ Identification label (type L only): Heat shrinkable electrical insulation tubing Per
SAE-AMS-DTL-23053/5, “Insulation Sleeving, Electrical, Heat Shrinkable, Polyolefin, Flexible, CLASS I,
color black,.250" I.D. size.
Assembly resistance: See table II.
Tensile strength: See table II. Perform after the flexibility test in accordance with MIL-DTL-83413 group
II qualification sequence. Omit assembly resistance as a tensile strength post test.
Crimping tools and crimping dies: See table II.
Source: http://assist.dla.mil -- Downloaded: 2021-02-08T11:20ZCheck the source to verify that this is the current version before use.