Introducing the Type 4
Compact Light Curtain
panasonic.net/id/pidsx/global
2013.12
SERIES
SF4B-C
Light Curtain
Compact Type4 PLe SIL3
Conforming to Machine
& EMC Directive
Conforming to
OSHA/ANSI
Certified Certified by NRTL
Certified
Compact, light weight design,
and advanced functionality in one package:
A new concept “Compact Light Curtain”
Compact profile design,
maximize the machinery opening area
The SF4B-C series is designed to fit onto an aluminum frame, maximizing the machinery opening area.
It can even allow zero dead zone.
* When using standard mounting brackets (optional)
Rear mounting
Side mounting
Issues when installing on the
inside of the machinery opening area
Buried mounting (side)
* When using standard mounting brackets
(optional)
* When using standard mounting brackets
(optional)
SF4B-C SERIES
High
functionality
SF4B-CSERIES
Light
weight
Compact
design
Compact design
Width
Just
20 mm
Depth
27
.4 mm
1.079 in
Dead zone
Dead zone
Bracket
Light curtain
mounting bracket
Bracket
Light curtain
mounting bracket
Fit onto aluminum
frame perfectly
Fit onto aluminum
frame perfectly
Compact Light Curtain
The SF4B-C series comes in the size of 20 (W) × 27.4 (D) mm 0.787 (W) × 1.079 (D) in,
which is designed to be compact, light weight and easy to install.
We offer the extensive selection of safety features including muting and blanking.
The presence of light curtain does not narrow the
opening area.
The light curtain is thin, so its bulge from frame can
be minimized.
Brackets in the
corners of the
aluminum frame
result in dead zone.
Additional protective
guard is required for
the dead zone.
The light curtain fits onto frame
perfectly, even in embedded
installations.
The light curtain protrudes
neither into the machinery
opening nor outside the frame.
The light curtain will not be
damaged due to collision with
workpiece.
The light curtain fits onto a
20 × 20 mm 0.787 × 0.787 in
aluminum frame perfectly.
The light curtain does not
protrude from the frame.
0.787 in
2
Compact, light weight design,
and advanced functionality in one package:
A new concept “Compact Light Curtain”
Compact profile design,
maximize the machinery opening area
The SF4B-C series is designed to fit onto an aluminum frame, maximizing the machinery opening area.
It can even allow zero dead zone.
* When using standard mounting brackets (optional)
Rear mounting
Side mounting
Issues when installing on the
inside of the machinery opening area
Buried mounting (side)
* When using standard mounting brackets
(optional)
* When using standard mounting brackets
(optional)
SF4B-C SERIES
High
functionality
SF4B-CSERIES
Light
weight
Compact
design
Compact design
Width
Just
20 mm
Depth
27
.4 mm
1.079 in
Dead zone
Dead zone
Bracket
Light curtain
mounting bracket
Bracket
Light curtain
mounting bracket
Fit onto aluminum
frame perfectly
Fit onto aluminum
frame perfectly
Compact Light Curtain
The SF4B-C series comes in the size of 20 (W) × 27.4 (D) mm 0.787 (W) × 1.079 (D) in,
which is designed to be compact, light weight and easy to install.
We offer the extensive selection of safety features including muting and blanking.
■ The presence of light curtain does not narrow the
opening area.
■ The light curtain is thin, so its bulge from frame can
be minimized.
Brackets in the
corners of the
aluminum frame
result in dead zone.
Additional protective
guard is required for
the dead zone.
The light curtain fits onto frame
perfectly, even in embedded
installations.
The light curtain protrudes
neither into the machinery
opening nor outside the frame.
The light curtain will not be
damaged due to collision with
workpiece.
The light curtain fits onto a
20 × 20 mm 0.787 × 0.787 in
aluminum frame perfectly.
The light curtain does not
protrude from the frame.
0.787 in
Compact, light weight design,
and advanced functionality in one package:
A new concept “Compact Light Curtain”
Compact profile design,
maximize the machinery opening area
The SF4B-C series is designed to fit onto an aluminum frame, maximizing the machinery opening area.
It can even allow zero dead zone.
* When using standard mounting brackets (optional)
Rear mounting
Side mounting
Issues when installing on the
inside of the machinery opening area
Buried mounting (side)
* When using standard mounting brackets
(optional)
* When using standard mounting brackets
(optional)
SF4B-C SERIES
High
functionality
SF4B-CSERIES
Light
weight
Compact
design
Compact design
Width
Just
20 mm
Depth
27
.4 mm
1.079 in
Dead zone
Dead zone
Bracket
Light curtain
mounting bracket
Bracket
Light curtain
mounting bracket
Fit onto aluminum
frame perfectly
Fit onto aluminum
frame perfectly
Compact Light Curtain
The SF4B-C series comes in the size of 20 (W) × 27.4 (D) mm 0.787 (W) × 1.079 (D) in,
which is designed to be compact, light weight and easy to install.
We offer the extensive selection of safety features including muting and blanking.
The presence of light curtain does not narrow the
opening area.
The light curtain is thin, so its bulge from frame can
be minimized.
Brackets in the
corners of the
aluminum frame
result in dead zone.
Additional protective
guard is required for
the dead zone.
The light curtain fits onto frame
perfectly, even in embedded
installations.
The light curtain protrudes
neither into the machinery
opening nor outside the frame.
The light curtain will not be
damaged due to collision with
workpiece.
The light curtain fits onto a
20 × 20 mm 0.787 × 0.787 in
aluminum frame perfectly.
The light curtain does not
protrude from the frame.
0.787 in
3
(SF4B-CA-J05 only)
SF4B-C SERIES
Plastic × metal
The SF4B-C series features a proprietary double structure of a “plastic body” with a “metal inner frame”
which lightens the weight while maintaining the durability.
Light weight
Large multi-purpose indicator
The SF4B-C series incorporates a large multi-purpose indicator (orange) positioned around workers’
eye level. The indicator shows the presence of the light curtain, helping to prevent unintentional
beam interruption. The indicator can be used in a variety of applications such as a muting indicator
and work indicator.
High functionality
Exceptional visibility
with wide angle
The large multi-purpose indicator
shines brightly through the plastic body
to ensure exceptional visibility.
Thanks to its plastic body, the SF4B-C
series is 45% lighter* than previous
models with aluminum enclosures. This
helps to reduce the overall weight of the
equipment during transport and when
shipping it overseas.
* Comparing SF4B-H80 <V2> with
SF4B-H80CA-J05
Maximum protection
height of 1,943.4 mm
76.512 in
Despite its compact, plastic body, the
SF4B-C series features a metal inner
frame that increases toughness and
also keeps its enclosure not to curve.
Protective heights range from 263.4 mm
to 1,943.4 mm 10.370 in to 76.512 in.
Metal inner frame
Plastic
seamless
enclosure
* This is an only image
for seamless enclosure
partially cut.
Light
Durable
Max.
1,943.4 mm
76.512 in
Min.
263.4 mm
10.370 in
45% lighter* for easy
installation in high
places and when
mounting long models
Handy-controller
SFB-HC (optional) offers
easy access to settings
for a range of functionality
Extensive array of
other functions
High functionality
High functionality
PNP / NPN polarity support
Since a single model number can be switched between PNP and
NPN input, fewer model numbers need to be registered.
External device monitor function
External devices (such as safety relays, etc.) can be directly
connected to the handy-controller without any dedicated unit,
simplifying installation, reducing costs, and helping to avoid
various problems.
Extraneous light check & avoid (ELCA) function
The ELCA function reduces interference without an interference
prevention line.
Beam-axis alignment indicator
Beam-axis alignment indicators are indicated in 4 blocks, allowing
to see at a glance where light is being received.
Muting control function for
individual beams: Limit the
muting area
The SFB-HC handy-controller (optional) allows
to perform muting control for certain beams
only. Since beam channels can be specified,
so there is no need to install a separate guard
to prevent intrusions. For example, according
to the height of a sensing object, when muting
control from the lowermost beam channel to
the 10th beam channel is activated, the light
curtain will detect any beam interruption at the
11th or higher beam channel as a human entry
and stop the machinery.
Fixed blanking function:
Choose active beam channels
The SFB-HC handy-controller provides a
fixed blanking function that prevents
control output (OSSD) from turning off
even if certain beam channels are
interrupted. This function is convenient
for applications where an obstacle
always interrupts certain beam channels.
Additionally, it is safe since control output
(OSSD) is forcibly turned off in the event
the obstruction moves outside the
detection area.
Use output and indicators to achieve
preventive maintenance when the incident
light intensity gets unstable
By setting the auxiliary output switching function to off or on
when light reception becomes unstable, the light curtain
provides notification in the event of a reduction in the incident
light intensity due to beam misalignment or dirt via auxiliary
output (non-safety output) in addition to the incident light
intensity indicator.
Notes: 1) An incident light intensity value of 100 % refers to the threshold value
at which control outputs (OSSD1, OSSD2) change from off to on.
2) Interruption of the light refers to the presence of an object interrupts
beam in the detection area.
3) This setting is not available when using muting control for
individual beams, fixed blanking, or floating blanking.
Floating blanking function:
Disable unspecified beams
The floating blanking function allows to
disable up to three unspecified beam
channels. Control output (OSSD) will not
turn off as long as the number of
interrupted beam channels is less than
the set number of beam channels. This
function is convenient when an obstruction
moves inside the detection area during
setup changes or when loading materials
within the detection area of light curtain.
*The min. sensing object will change when the
floating blanking function is used.
During muting
(line operating) Line stopped
(SF4B-CA-J05 only)
Incident light intensity indicator
Auxiliary output
Set to off for
unstable incident
light (Note 3)
Under stable light received
condition: Green
Incident light intensity:
130 % or greater
130 %
100 %
Under unstable light received
condition: Orange
Incident light intensity:
100 % to less than 130 %
When light is interrupted
(Note 2): Off
Set to on for
unstable incident
light (Note 3)
ON OFF
OFF ON
Incident light
intensity (Note 1)
To control
circuits
4
(SF4B-CA-J05 only)
SF4B-C SERIES
Plastic × metal
The SF4B-C series features a proprietary double structure of a “plastic body” with a “metal inner frame”
which lightens the weight while maintaining the durability.
Light weight
Large multi-purpose indicator
The SF4B-C series incorporates a large multi-purpose indicator (orange) positioned around workers’
eye level. The indicator shows the presence of the light curtain, helping to prevent unintentional
beam interruption. The indicator can be used in a variety of applications such as a muting indicator
and work indicator.
High functionality
Exceptional visibility
with wide angle
The large multi-purpose indicator
shines brightly through the plastic body
to ensure exceptional visibility.
Thanks to its plastic body, the SF4B-C
series is 45% lighter* than previous
models with aluminum enclosures. This
helps to reduce the overall weight of the
equipment during transport and when
shipping it overseas.
* Comparing SF4B-H80 <V2> with
SF4B-H80CA-J05
Maximum protection
height of 1,943.4 mm
76.512 in
Despite its compact, plastic body, the
SF4B-C series features a metal inner
frame that increases toughness and
also keeps its enclosure not to curve.
Protective heights range from 263.4 mm
to 1,943.4 mm 10.370 in to 76.512 in.
Metal inner frame
Plastic
seamless
enclosure
* This is an only image
for seamless enclosure
partially cut.
Light
Durable
Max.
1,943.4 mm
76.512 in
Min.
263.4 mm
10.370 in
45% lighter* for easy
installation in high
places and when
mounting long models
Handy-controller
SFB-HC (optional) offers
easy access to settings
for a range of functionality
Extensive array of
other functions
High functionality
High functionality
PNP / NPN polarity support
Since a single model number can be switched between PNP and
NPN input, fewer model numbers need to be registered.
External device monitor function
External devices (such as safety relays, etc.) can be directly
connected to the handy-controller without any dedicated unit,
simplifying installation, reducing costs, and helping to avoid
various problems.
Extraneous light check & avoid (ELCA) function
The ELCA function reduces interference without an interference
prevention line.
Beam-axis alignment indicator
Beam-axis alignment indicators are indicated in 4 blocks, allowing
to see at a glance where light is being received.
Muting control function for
individual beams: Limit the
muting area
The SFB-HC handy-controller (optional) allows
to perform muting control for certain beams
only. Since beam channels can be specified,
so there is no need to install a separate guard
to prevent intrusions. For example, according
to the height of a sensing object, when muting
control from the lowermost beam channel to
the 10th beam channel is activated, the light
curtain will detect any beam interruption at the
11th or higher beam channel as a human entry
and stop the machinery.
Fixed blanking function:
Choose active beam channels
The SFB-HC handy-controller provides a
fixed blanking function that prevents
control output (OSSD) from turning off
even if certain beam channels are
interrupted. This function is convenient
for applications where an obstacle
always interrupts certain beam channels.
Additionally, it is safe since control output
(OSSD) is forcibly turned off in the event
the obstruction moves outside the
detection area.
Use output and indicators to achieve
preventive maintenance when the incident
light intensity gets unstable
By setting the auxiliary output switching function to off or on
when light reception becomes unstable, the light curtain
provides notification in the event of a reduction in the incident
light intensity due to beam misalignment or dirt via auxiliary
output (non-safety output) in addition to the incident light
intensity indicator.
Notes: 1) An incident light intensity value of 100 % refers to the threshold value
at which control outputs (OSSD1, OSSD2) change from off to on.
2) Interruption of the light refers to the presence of an object interrupts
beam in the detection area.
3) This setting is not available when using muting control for
individual beams, fixed blanking, or floating blanking.
Floating blanking function:
Disable unspecified beams
The floating blanking function allows to
disable up to three unspecified beam
channels. Control output (OSSD) will not
turn off as long as the number of
interrupted beam channels is less than
the set number of beam channels. This
function is convenient when an obstruction
moves inside the detection area during
setup changes or when loading materials
within the detection area of light curtain.
*The min. sensing object will change when the
floating blanking function is used.
During muting
(line operating) Line stopped
(SF4B-CA-J05 only)
Incident light intensity indicator
Auxiliary output
Set to off for
unstable incident
light (Note 3)
Under stable light received
condition: Green
Incident light intensity:
130 % or greater
130 %
100 %
Under unstable light received
condition: Orange
Incident light intensity:
100 % to less than 130 %
When light is interrupted
(Note 2): Off
Set to on for
unstable incident
light (Note 3)
ON OFF
OFF ON
Incident light
intensity (Note 1)
To control
circuits
54
SF4B-C
6
PRODUCT CONFIGURATION
ORDER GUIDE
Pigtailed type (with muting function)
(with 0.5 m 1.640 ft connector attached cable)
Cable type
(with 5 m 16.404 ft cable)
2
Cable 5 m 16.404 ft (discrete wire)
1
5 4 3
3
Connector attached cable 0.5 m 1.640 ft
1 2 Light curtains
Type Appearance Operating range
(Note 1)
Model No. (Note 2) Number
of beam
channels
Protective height
1 Pigtailed type
(with muting function)
2 Cable type
Hand protection type
Min. sensing object ø25 mm ø0.984 in
(20 mm 0.787 in beam pitch)
Beam pitch
Protective height
22.2 mm 0.874 in
Beam
channel No.
22.2 mm
0.874 in
20 mm
0.787 in
0.3 to 7 m
0.984 to 22.966 ft
SF4B-H12CA-J05 SF4B-H12C 12 263.4 mm 10.370 in
SF4B-H16CA-J05 SF4B-H16C 16 343.4 mm 13.520 in
SF4B-H20CA-J05 SF4B-H20C 20 423.4 mm 16.669 in
SF4B-H24CA-J05 SF4B-H24C 24 503.4 mm 19.819 in
SF4B-H28CA-J05 SF4B-H28C 28 583.4 mm 22.969 in
SF4B-H32CA-J05 SF4B-H32C 32 663.4 mm 26.118 in
SF4B-H36CA-J05 SF4B-H36C 36 743.4 mm 29.268 in
SF4B-H40CA-J05 SF4B-H40C 40 823.4 mm 32.417 in
SF4B-H48CA-J05 SF4B-H48C 48 983.4 mm 38.717 in
SF4B-H56CA-J05 SF4B-H56C 56 1,143.4 mm 45.016 in
SF4B-H64CA-J05 SF4B-H64C 64 1,303.4 mm 51.315 in
SF4B-H72CA-J05 SF4B-H72C 72 1,463.4 mm 57.614 in
SF4B-H80CA-J05 SF4B-H80C 80 1,623.4 mm 63.913 in
SF4B-H88CA-J05 SF4B-H88C 88 1,783.4 mm 70.212 in
SF4B-H96CA-J05 SF4B-H96C 96 1,943.4 mm 76.512 in
Arm / Foot protection type
Min. sensing object ø45 mm ø1.772 in
(40 mm 1.575 in beam pitch)
Beam pitch
Protective
height
40 mm
1.575 in
Beam
channel No.
42.2 mm
1.661 in
42.2 mm 1.661 in
0.3 to 7 m
0.984 to 22.966 ft
SF4B-A8CA-J05 SF4B-A8C 8 343.4 mm 13.520 in
SF4B-A12CA-J05 SF4B-A12C 12 503.4 mm 19.819 in
SF4B-A16CA-J05 SF4B-A16C 16 663.4 mm 26.118 in
SF4B-A20CA-J05 SF4B-A20C 20 823.4 mm 32.417 in
SF4B-A24CA-J05 SF4B-A24C 24 983.4 mm 38.717 in
SF4B-A28CA-J05 SF4B-A28C 28 1,143.4 mm 45.016 in
SF4B-A32CA-J05 SF4B-A32C 32 1,303.4 mm 51.315 in
SF4B-A36CA-J05 SF4B-A36C 36 1,463.4 mm 57.614 in
SF4B-A40CA-J05 SF4B-A40C 40 1,623.4 mm 63.913 in
SF4B-A44CA-J05 SF4B-A44C 44 1,783.4 mm 70.212 in
SF4B-A48CA-J05 SF4B-A48C 48 1,943.4 mm 76.512 in
Notes: 1) The operating range is the distance possible to set between the emitter and the receiver.
0.3 m 0.984 ft
7 m 22.966 ft
Receiver cannot be
placed in this range
Emitter
Setting range of
the receiver
Actual operating range
of the light curtain
Receiver Receiver
2) The model No. with “E” shown on the label afxed to the product is the emitter, “D” shown on the label is the receiver.
SF4B-C
7
ORDER GUIDE
Designation Appearance Model No. Description
Standard mounting
bracket MS-SF4BC-1
Allows the light curtain to be mounted on the rear or side of the
target equipment. Designed for use with one M5 hexagon-socket
head bolt.
(4 pcs. per set for the emitter and receiver)
Rear utility mounting
bracket MS-SF4BC-2
Allows the light curtain to be mounted on the rear of the target
equipment. Allows beam adjustment. Designed for use with one
M5 hexagon-socket head bolt. For space-saving mounting, use
one M5 hexagon head bolt.
(4 pcs. per set for the emitter and receiver)
Side utility mounting
bracket MS-SF4BC-3
Allows the light curtain to be mounted on the side of the target
equipment. Allows beam adjustment. Designed for use with one
M5 hexagon-socket head bolt. For space-saving mounting, use
one M5 hexagon head bolt.
(4 pcs. per set for the emitter and receiver)
Intermediate supporting
bracket for utility
mounting bracket
(Note 1)
MS-SF4BC-4
Supports the middle of the light curtain when installing it with
utility mounting brackets. Allows the light curtain to be mounted
on the rear or side of the target equipment. Allows beam
adjustment. Designed for use with one M5 hexagon head bolt.
(2 pcs. each per set for rear mounting and side mounting)
Intermediate supporting
bracket for standard
mounting bracket
(Note 1)
MS-SF4BC-5
Supports the middle of the light curtain when installing it with
standard mounting brackets. Allows the light curtain to be
mounted on the rear or side of the target equipment. Designed
for use with two M3 countersunk screws.
(2 pcs. each per set for rear mounting and side mounting)
Side mounting bracket MS-SF4BC-6
Allows beam axis alignment and the light curtain to be mounted
on the device in conned spaces. Designed for use with one M5
hexagon-socket head bolt. (4 pcs. per set for the emitter and
receiver)
Intermediate supporting
bracket for use with side
mounting bracket
(Note 1)
MS-SF4BC-7
Supports the middle of the light curtain when installing it with side
mounting brackets. Allows beam axis alignment and the light
curtain to be mounted on the device in conned spaces.
Designed for use with one M5 hexagon-socket head bolt.
(2 pces. per set)
Note 1: The numbers of sets required by SF4B-H□C (A-J05) (40 or more beam axes) and SF4B-A□C (A-J05) (20 or more beam axes) are as follows:
SF4B-H40C (A-J05), SF4B-H48C (A-J05), SF4B-H56C (A-J05), SF4B-A20C (A-J05), SF4B-A24C (A-J05), SF4B-A28C (A-J05): 1 set
SF4B-H64C (A-J05), SF4B-H72C (A-J05), SF4B-H80C (A-J05), SF4B-H88C (A-J05), SF4B-H96C (A-J05), SF4B-A32C (A-J05), SF4B-A36C (A-J05),
SF4B-A40C (A-J05), SF4B-A44C (A-J05), SF4B-A48C (A-J05): 2 sets
3 Mounting brackets Mounting bracket is not supplied with the light curtain. Be sure to order it separately.
Note 2: For space-saving mounting, use an M5 hexagon head bolt
Side utility mounting bracket and
intermediate supporting bracket
for utility mounting bracket
Intermediate
supporting
bracket for
utility mounting
bracket
MS-SF4BC-4
Side utility
mounting bracket
MS-SF4BC-3
Side utility
mounting bracket
MS-SF4BC-3
• MS-SF4BC-3
Four brackets (two each R and L type) per set
Eight M3 (length: 6 mm 0.236 in) hexagon-socket
head bolts and four M5 at washers are attached.
• MS-SF4BC-4
Two brackets per set
M5 at washers, two pcs. assembled M3 (length:
6 mm 0.236 in) hexagon-socket head bolts for rear
mounting, two pcs. attachments for side mounting
Standard
mounting
Space-saving
mounting (Note 2)
Side mounting bracket and
intermediate supporting bracket
for use with side mounting
bracket
• MS-SF4BC-6
Four brackets (two each R and L type) per set
Eight M3 (length: 6 mm 0.236 in) hexagon-socket
head bolts and four M5 at washers are attached.
• MS-SF4BC-7
Two brackets per set
Two pcs. M5 at washers, two pcs. assembled
M3 (length: 6 mm 0.236 in) hexagon-socket head
bolts for side mounting
Standard
mounting
Space-saving
mounting
Rear utility mounting bracket and
intermediate supporting bracket
for utility mounting bracket
• MS-SF4BC-2
Four brackets (two each R and L type) per set
Eight M3 (length: 6 mm 0.236 in) hexagon-socket
head bolts and four M5 at washers are attached.
• MS-SF4BC-4
Two brackets per set
M5 at washers, two pcs. assembled M3 (length:
6 mm 0.236 in) hexagon-socket head bolts for rear
mounting, two pcs. attachments for side mounting
Space-saving
mounting (Note 2)
Standard
mounting
Intermediate
supporting
bracket for utility
mounting
bracket
MS-SF4BC-4
Rear utility
mounting bracket
MS-SF4BC-2
Rear utility
mounting
bracket
MS-SF4BC-2
Standard mounting bracket and
intermediate supporting bracket
for standard mounting bracket
• MS-SF4BC-1
Four brackets (two each R and L type) per set
Eight M3 (length: 5 mm 0.197 in) hexagon-socket
head bolts and four M5 at washers are attached.
• MS-SF4BC-5
Two pcs. for rear mounting, two pcs. for side mounting
In case of rear
mounting
In case of side
mounting
Standard
mounting bracket
MS-SF4BC-1
Standard
mounting bracket
MS-SF4BC-1
Intermediate
supporting bracket
for standard
mounting bracket
MS-SF4BC-5
Intermediate
supporting
bracket for use
with side
mounting
bracket
MS-SF4BC-7
Side mounting
bracket
MS-SF4BC-6
Side mounting
bracket
MS-SF4BC-6
SF4B-C
8
ORDER GUIDE
4 5
Mating cables
Type Appearance Model No. Description
Mating cables
4
With connector on
one end
SFB-CC3-MU
Length: 3 m 9.843 ft
Net weight: 430 g approx. (2 cables)
Cable with connector on one end for pigtailed type (with
muting function)
Two cables per set for emitter and receiver
Cable color: Gray for emitter,
Gray with black line for receiver
Connector color: Gray for emitter, Black for receiver
Min. bending radius: R6 mm R0.236 in
SFB-CC7-MU
Length: 7 m 22.966 ft
Net weight: 1,000 g approx. (2 cables)
SFB-CC10-MU
Length: 10 m 32.808 ft
Net weight: 1,300 g approx. (2 cables)
With connectors on both ends
5
For emitter
SFB-CCJ3E-MU
Length: 3 m 9.843 ft
Net weight: 190 g approx. (1 cable)
Cable with connectors on both ends for pigtailed type
(with muting function)
Cable color: Gray for emitter,
Gray with black line for receiver
Connector color: Gray for emitter, Black for receiver
Min. bending radius: R6 mm R0.236 in
SFB-CCJ10E-MU
Length: 10 m 32.808 ft
Net weight: 660 g approx. (1 cable)
For receiver
SFB-CCJ3D-MU
Length: 3 m 9.843 ft
Net weight: 210 g approx. (1 cable)
SFB-CCJ10D-MU
Length: 10 m 32.808 ft
Net weight: 680 g approx. (1 cable)
Designation Model No. Description
Test rod ø25 SF4B-TR25 Min. sensing object for regular checking (ø25 mm ø0.984 in),
for hand protection type (min. sensing object ø25 mm ø0.984 in)
Spare parts (Accessories for light curtain)
Designation Appearance Model No. Description
Slim type
control
unit
SF-C13
Use a discrete wire cable to connect to the light curtain. Muting function can be
used. Compatible with up to Control Category 4.
When connecting pigtailed type (with muting function) SF4B-□CA-J05, be sure to
order a mating cable separately.
• Mating cable: SFB-CC□-MU
• Extension cable: SFB-CCJ□-MU
OPTIONS
Control units
Handy-controller
Designation Appearance Model No.
Handy-
controller SFB-HC
Cable set for
cable type
connection
SFC-WNC1
Fixedblanking
Code
Protect
Copy
FUNCTION
CANCEL
ENTER
Monitor
Floatingblanking
Auxiliaryoutput
Lightemission
control
* 2 adapter cables
included
FUNCTION
CANCEL
ENTER
Adapter cable (Accessory) Adapter cable (Accessory)
Extension cable
8-core → 12-core12-core → 8-core
8-
core 8-
core
Handy-controller
Pigtailed type (with muting function)
Cable set
+V
Synchronization +
Synchronization -
0V
Terminal block
Cable type
Not used
Handy-controller
Control
circuit
FUNCTION
CANCEL
ENTER
SF4B-C
9
Designation Model No. Description
Test rod ø45 SF4B-TR45
Min. sensing object for regular checking (ø45 mm ø1.772 in),
for arm / foot protection type (min. sensing object ø45 mm
ø1.772 in)
Large display
unit for light
curtain
SF-IND-2
With the auxiliary output of the light curtain, the operation is
easily observable from various directions.
Specications
Supply voltage: 24 V DC ±15 %
Current consumption: 12 mA or less
Indicators: Orange LED (8 pcs. used)
[Light up when external contact is ON]
Ambient temperature: –10 to +55 °C +14 to +131 °F
(No dew condensation or icing allowed)
Material: POM (Enclosure)
Polycarbonate (Cover)
Cold rolled carbon steel (SPCC) (Bracket)
Cable: 0.3 mm2 2-core cabtyre cable, 3 m 9.843 ft long
Weight: 70 g approx. (including bracket)
Large display unit
for light curtain
SF-IND-2
* Cannot be attached together with a
mounting bracket to the light curtain
using a single bolt.
OPTIONS
Safety relay
Panasonic Corporation
SF series
● Recommended safety relay
Note: Contact Panasonic Corporation for details on the
recommended products.
Type With LED indicator
Model No. SFS3-L-DC24V SFS4-L-DC24V
Item Part No. AG1S132 AG1S142
Contact arrangement 3a1b 4a2b
Rated nominal switching
capacity 6 A / 250 V AC, 6 A / 30 V DC
Min. switching capacity 1 mA / 5 V DC
Coil rating 15 mA / 24 V DC 20.8 mA / 24 V DC
Rated power consumption 360 mW 500 mW
Operation time 20 ms or less
Release time 20 ms or less
Ambient temperature –40 to +85 °C –40 to +185 °F
(Humidity: 5 to 85 % RH)
Applicable standards UL, C-UL, TU
••
V
Safety relay
SFS3-L-DC24V
(AG1S132)
SFS4-L-DC24V
(AG1S142)
DIN terminal block
SFS4-SFD
(AG1S847)
Others
Designation
Metal protection case
Applicable beam channels
Hand protection
type
Arm / Foot
protection type Model No.
12 MS-SF4BCH-12
16 8 MS-SF4BCH-16
20 MS-SF4BCH-20
24 12 MS-SF4BCH-24
28 MS-SF4BCH-28
32 16 MS-SF4BCH-32
36 MS-SF4BCH-36
40 20 MS-SF4BCH-40
48 24 MS-SF4BCH-48
56 28 MS-SF4BCH-56
64 32 MS-SF4BCH-64
72 36 MS-SF4BCH-72
80 40 MS-SF4BCH-80
88 44 MS-SF4BCH-88
96 48 MS-SF4BCH-96
Metal protection case On sale soon
MS-SF4BCH-□
M5 hexagon-
socket head bolt
length: 10 mm
0.394 in or more
Purchase separately.
SF4B-C
10
Light curtain individual specifications
Type Min. sensing object ø25 mm ø0.984 in (20 mm 0.787 in beam pitch)
Model No.
Pigtailed type
SF4B-H12CA-J05 SF4B-H16CA-J05 SF4B-H20CA-J05 SF4B-H24CA-J05 SF4B-H28CA-J05 SF4B-H32CA-J05 SF4B-H36CA-J05
Item Cable type SF4B-H12C SF4B-H16C SF4B-H20C SF4B-H24C SF4B-H28C SF4B-H32C SF4B-H36C
Number of beam channels 12 16 20 24 28 32 36
Protective height 263.4 mm
10.37 in
343.4 mm
13.52 in
423.4 mm
16.669 in
503.4 mm
19.819 in
583.4 mm
22.969 in
663.4 mm
26.118 in
743.4 mm
29.268 in
Current consumption
Cable type
Emitter: 65 mA or less, Receiver: 75 mA or less Emitter: 70 mA or less
Receiver: 85 mA or less
Emitter: 75 mA or less
Receiver: 95 mA or less
Pigtailed
type
When large multi-purpose
indicator turns OFF
When large multi-purpose
indicator lights up
Emitter: 75 mA or less, Receiver: 85 mA or less Emitter: 80 mA or less
Receiver: 95 mA or less
Emitter: 85 mA or less
Receiver: 105 mA or less
PFHD (Note) 1.9 × 10−9 2.1 × 10−9 2.4 × 10−9 2.6 × 10−9 2.8 × 10−9 3.0 × 10−9 3.3 × 10−9
MTTFd (Note) 100 years or more
Net weight
(Total of emitter and receiver)
Pigtailed type Approx. 360 g Approx. 430 g Approx.520 g Approx. 590 g Approx. 680 g Approx. 750 g Approx. 840 g
Cable type Approx. 700 g Approx. 770 g Approx. 860 g Approx. 930 g Approx. 1,000 g Approx. 1,100 g Approx. 1,200 g
Type Min. sensing object ø25 mm ø0.984 in (20 mm 0.787 in beam pitch)
Model No.
Pigtailed type
SF4B-H40CA-J05 SF4B-H48CA-J05 SF4B-H56CA-J05 SF4B-H64CA-J05 SF4B-H72CA-J05 SF4B-H80CA-J05 SF4B-H88CA-J05
Item Cable type SF4B-H40C SF4B-H48C SF4B-H56C SF4B-H64C SF4B-H72C SF4B-H80C SF4B-H88C
Number of beam channels 40 48 56 64 72 80 88
Protective height 823.4 mm
32.417 in
983.4 mm
38.717 in
1,143.4 mm
45.016 in
1,303.4 mm
51.315 in
1,463.4 mm
57.614 in
1,623.4 mm
63.913 in
1,783.4 mm
70.212 in
Current consumption
Cable type Emitter: 80 mA or less
Receiver: 100 mA or less
Emitter: 85 mA or less
Receiver: 120 mA or less
Emitter: 95 mA or less
Receiver: 130 mA or less
Emitter: 100 mA or less
Receiver: 140 mA or less
Pigtailed
type
When large multi-purpose
indicator turns OFF
When large multi-purpose
indicator lights up
Emitter: 90 mA or less
Receiver: 110 mA or less
Emitter: 95 mA or less
Receiver: 130 mA or less
Emitter: 105 mA or less
Receiver: 140 mA or less
Emitter: 110 mA or less
Receiver: 155 mA or less
PFHD (Note) 3.5 × 10−9 3.9 × 10−9 4.4 × 10−9 4.8 × 10−9 5.3 × 10−9 5.7 × 10−9 6.2 × 10−9
MTTFd (Note) 100 years or more
Net weight
(Total of emitter and receiver)
Pigtailed type Approx. 910 g Approx. 1,100 g Approx. 1,300 g Approx. 1,400 g Approx. 1,600 g Approx. 1,700 g Approx. 1,800 g
Cable type Approx. 1,300 g Approx. 1,400 g Approx. 1,600 g Approx. 1,700 g Approx. 2,000 g Approx. 2,000 g Approx. 2,100 g
Type Min. sensing object ø45 mm ø1.772 in (40 mm 1.575 in beam pitch)
Model No.
Pigtailed type
SF4B-A32CA-J05 SF4B-A36CA-J05 SF4B-A40CA-J05 SF4B-A44CA-J05 SF4B-A48CA-J05
Item Cable type SF4B-A32C SF4B-A36C SF4B-A40C SF4B-A44C SF4B-A48C
Number of beam channels 32 36 40 44 48
Protective height 1,303.4 mm
51.315 in
1,463.4 mm
57.614 in
1,623.4 mm
63.913 in
1,783.4 mm
70.212 in
1,943.4 mm
76.512 in
Current consumption
Cable type Emitter: 75 mA or less
Receiver: 95 mA or less
Emitter: 80 mA or less
Receiver: 100 mA or less
Pigtailed
type
When large multi-purpose
indicator turns OFF
When large multi-purpose
indicator lights up
Emitter: 85 mA or less
Receiver: 105 mA or less
Emitter: 90 mA or less
Receiver: 110 mA or less
PFHD (Note) 3.2 × 10−9 3.4 × 10−9 3.7 × 10−9 3.9 × 10−9 4.2 × 10−9
MTTFd (Note) 100 years or more
Net weight
(Total of emitter and receiver)
Pigtailed type Approx. 1,400 g Approx. 1,600 g Approx. 1,700 g Approx. 1,800 g Approx. 1,900 g
Cable type Approx. 1,700 g Approx. 2,000 g Approx. 2,000 g Approx. 2,100 g Approx. 2,200 g
SF4B-H□C (A-J05)
Type
Min. sensing object ø25
mm ø0.984 in (20 mm
0.787 in beam pitch)
Min. sensing object ø45 mm ø1.772 in (40 mm 1.575 in beam pitch)
Model No.
Pigtailed type
SF4B-H96CA-J05 SF4B-A8CA-J05 SF4B-A12CA-J05 SF4B-A16CA-J05 SF4B-A20CA-J05 SF4B-A24CA-J05 SF4B-A28CA-J05
Item Cable type SF4B-H96C SF4B-A8C SF4B-A12C SF4B-A16C SF4B-A20C SF4B-A24C SF4B-A28C
Number of beam channels 96 8 12 16 20 24 28
Protective height 1,943.4 mm
76.512 in
343.4 mm
13.52 in
503.4 mm
19.819 in
663.4 mm
26.118 in
823.4 mm
32.417 in
983.4 mm
38.717 in
1,143.4 mm
45.016 in
Current consumption
Cable type
Emitter: 105 mA or less
Receiver: 145 mA or less
Emitter: 60 mA or less
Receiver: 70 mA or less
Emitter: 65 mA or less
Receiver: 75 mA or less
Emitter: 70 mA or less
Receiver: 85 mA or less
Pigtailed
type
When large multi-purpose
indicator turns OFF
When large multi-purpose
indicator lights up
Emitter: 115 mA or less
Receiver: 155 mA or less
Emitter: 70 mA or less
Receiver: 80 mA or less
Emitter: 75 mA or less
Receiver: 85 mA or less
Emitter: 80 mA or less
Receiver: 95 mA or less
PFHD (Note) 6.6 × 10−9 1.7 × 10−9 1.9 × 10−9 2.2 × 10−9 2.4 × 10−9 2.7 × 10−9 2.9 × 10−9
MTTFd (Note)
100 years or more
100 years or more
Net weight
(Total of emitter and receiver)
Pigtailed type Approx. 1,900 g Approx. 430 g Approx. 590 g Approx. 750 g Approx. 910 g Approx. 1,100 g Approx. 1,300 g
Cable type Approx. 2,200 g Approx. 770 g Approx. 930 g Approx. 1,100 g Approx. 1,300 g Approx. 1,400 g Approx. 1,600 g
SF4B-A□C (A-J05)
Note: PFHd: Probability of dangerous failure per hour, MTTFd: Mean time to dangerous failure.
SPECIFICATIONS
Note: PFHd: Probability of dangerous failure per hour, MTTFd: Mean time to dangerous failure.
SF4B-C
11
SPECIFICATIONS
Light curtain common specifications
Notes: 1) Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +20 °C +68 °F.
2) Regarding EU Machinery Directive, a Notified Body, TU
••
V SU
••
D, has certified with the type examination certificate.
3) The product has been safety-certified in accordance with UL, ANSI, CSA, and other standards by TU
••
V SU
••
D, a nationally recognized safety laboratory
(NRTL) that has been approved by the Occupational Safety and Health Administration (OSHA) as defined by 29 CFR 1910.7
4) The operating range is the possible setting distance between the emitter and the receiver.
5) In case the blanking function is valid, the operation mode is changed. For details, refer to Safety distance (p.22)
6) During muting, control output will not turn off even if the beams are interrupted.
7) When the blanking function is enabled, the operating mode will change.
8) The manual reset and automatic reset are possible to be switched depending on the wiring status.
9) In case of using optional function, the handy-controller SFB-HC is required.
10) Do not use or store the device in an environment where the air pressure is higher than the atmospheric pressure at an altitude of 0 meters.
Type
Pigtailed type (with muting function) Cable type
Min. sensing object
ø25 mm ø0.984 in
(20 mm 0.787 in beam pitch)
Min. sensing object
ø45 mm ø1.772 in
(40 mm 1.575 in beam pitch)
Min. sensing object
ø25 mm ø0.984 in
(20 mm 0.787 in beam pitch)
Min. sensing object
ø45 mm ø1.772 in
(40 mm 1.575 in beam pitch)
Item Model No. SF4B-H□CA-J05 SF4B-A□CA-J05 SF4B-H□C SF4B-A□C
Applicable standards
International standard IEC 61496-1/2 (Type 4), ISO 13849-1 (Category 4, PLe), IEC 61508-1 to 7 (SIL3)
Japan JIS B 9704-1/2 (Type 4), JIS B 9705-1 (Category 4), JIS C 0508 (SIL3)
Europe (EU) (Note 2) EN 61496-1 (Type 4), EN ISO 13849-1 (Category 4, PLe), EN 61508-1 to 7 (SIL3),
EN 55011, EN 50178, EN 61000-6-2
North America (Note 3)
ANSI/UL 61496-1/2 (Type 4), ANSI/UL 508, CAN/CSA 61496-1/2 (Type 4), CAN/CSA C22.2 No.14,
OSHA 1910.212, OSHA 1910.217(C), ANSI B11.1 to B11.19, ANSI/RIA 15.06
South Korea (S-Mark)
S1-G-35-2005, S2-W-11-2003
Operating range (Note 4) 0.3 to 7 m 0.984 to 22.966 ft
Beam pitch 20 mm 0.787 in 40 mm 1.575 in 20 mm 0.787 in 40 mm 1.575 in
Min. sensing object (Note 5)
ø25 mm ø0.984 in opaque object ø45 mm ø1.772 in opaque object ø25 mm ø0.984 in opaque object ø45 mm ø1.772 in opaque object
Effective aperture angle ±2.5° or less [for an operating range exceeding 3 m 9.843 ft (conforming to IEC 61496-2 / UL 61496-2)]
Supply voltage 24 V DC ±10 % Ripple P-P 10 % or less
Control outputs
(OSSD 1, OSSD 2)
PNP open-collector transistor / NPN open-collector transistor (switching method)
<For PNP output>
Maximum source current: 200 mA
Applied voltage: Same as supply voltage (between the control output
and +V)
Residual voltage: 2.5 V or less
(source current 200 mA, when using 20 m 65.617 ft length cable)
Leakage current: 0.1 mA or less (Including power supply OFF
condition)
Maximum load capacity: 0.22 μF (No load to maximum output current)
Load wiring resistance: 3 Ω or less
<For NPN output>
Maximum sink current: 200 mA
Applied voltage: Same as supply voltage (between the control output
and 0 V)
Residual voltage: 2.5 V or less
(sink current 200 mA, when using 20 m 65.617 ft length cable)
Leakage current: 0.1 mA or less (Including power supply OFF
condition)
Maximum load capacity: 0.22 μF (No load to maximum output current)
Load wiring resistance: 3 Ω or less
Operation mode
ON when all beam channels are received, OFF when one or more beam channels are interrupted (OFF also in case of any malfunction in the light curtain or the synchronization signal) (Note 6, 7)
Protection circuit Incorporated
Response time OFF response: 14 ms or less, ON response: 80 to 90 ms
Auxiliary output
(Non-safety output)
PNP open-collector transistor / NPN open-collector transistor (switching method)
<For PNP output>
Maximum source current: 60 mA
Applied voltage: Same as supply voltage (between the auxiliary
output and +V)
Residual voltage: 2.5 V or less
(source current 60 mA, when using 20 m 65.617 ft length cable)
<For NPN output>
Maximum sink current: 60 mA
Applied voltage: Same as supply voltage (between the auxiliary
output and 0 V)
Residual voltage: 2.5 V or less
(sink current 60 mA, when using 20 m 65.617 ft length cable)
Operation mode
OFF when control outputs are ON, ON when control outputs are OFF (Factory setting, operating mode can be changed using the SFB-HC handy-controller.)
Protection circuit Incorporated
Muting auxiliary output
NPN open-collector transistor
Maximum sink current: 100 mA
Applied voltage: Same as supply voltage (between the
muting auxiliary output and 0 V)
Residual voltage: 2.5 V or less (sink current 100 mA, when
using 20 m 65.617 ft length cable)
Operation mode When muting auxiliary output: ON
Protection circuit Incorporated
ELCA function Incorporated (reducing mutual interference automatically)
Emission halt function Incorporated
Interlock function Incorporated [Manual reset / Auto reset (Note 8)]
External device monitoring function
Incorporated
Override function Incorporated
Muting function Incorporated
Large multi-purpose indicator function
Incorporated
Optional functions
Muting setting changing, override setting changing, fixed
blanking, floating blanking, light emitting amount control,
auxiliary output switching, protecting, interlock setting
changing, external relay monitor setting changing
Fixed blanking, floating blanking, light emitting amount control,
auxiliary output switching, protecting, interlock setting
changing, external relay monitor setting changing
Pollution degree 3
Operating altitude 2,000 m 6,561.68 ft or less (Note 10)
Environmental resistance
Degree of protection IP65 (IEC)
Ambient temperature –10 to +55 °C +14 to +131 °F (No dew condensation or icing allowed), Storage: –25 to +60 °C –3 to +140 °F
Ambient humidity 30 to 85 % RH, Storage: 30 to 85 % RH
Ambient illuminance Incandescent light: 3,500 ℓx or less at the light-receiving face
Dielectric strength voltage /
Insulation resistance
1,000 V AC for one min. between all supply terminals connected together and enclosure / 20 MΩ or more, with 500 V DC
megger between all supply terminals connected together and enclosure
Vibration resistance / Shock
resistance
10 to 55 Hz frequency, 0.75 mm 0.030 in amplitude in X, Y and Z directions for two hours each / 300 m/s2 acceleration
(30 G approx.) in X, Y and Z directions for three times each
SF4B-C
12
SPECIFICATIONS
Light curtain common specifications
Type
Pigtailed type (with muting function) Cable type
Min. sensing object
ø25 mm ø0.984 in
(20 mm 0.787 in beam pitch)
Min. sensing object
ø45 mm ø1.772 in
(40 mm 1.575 in beam pitch)
Min. sensing object
ø25 mm ø0.984 in
(20 mm 0.787 in beam pitch)
Min. sensing object
ø45 mm ø1.772 in
(40 mm 1.575 in beam pitch)
Item Model No. SF4B-H□CA-J05 SF4B-A□CA-J05 SF4B-H□C SF4B-A□C
Emitting element Infrared LED (Peak emission wavelength: 850 nm 0.033 mil)
Material Enclosure: Polycarbonate
Cable
0.15 mm
2
(power line: 0.2 mm
2
) 12-core heat-resistant PVC
cable with connector, 0.5 m 1.640 ft long
0.15 mm2 (power line: 0.2 mm2) 8-core heat-resistant PVC
cable, 5 m 16.404 ft long
Cable extension Extension up to total 50 m 164.042 ft is possible for both
emitter and receiver optional mating cables
Extension up to total 50 m 164.042 ft is possible for 0.2 mm2
or more, cable (Note 11)
Accessories SF4B-TR25 (Test rod): 1 pc. SF4B-TR25 (Test rod): 1 pc.
Control units
Model No. SF-C13
Item
Connectable light curtains Light curtains manufactured by Panasonic Industrial Devices SUNX
Applicable standards
EN 61496-1 (Type 4), EN 55011, EN ISO 13849-1 (Category 4, PLe), IEC 61496-1 (Type 4),
ISO 13849-1 (Category 4, PLe), JIS B 9704-1 (Type 4), JIS B 9705-1 (Category 4),
ANSI/UL 61496-1 (Type 4), UL 1998 (Class 2)
Control category ISO 13849-1 (EN ISO 13849-1, JIS B 9705-1) compliance up to Category 4, PLe standards
Supply voltage 24 V DC ±10 % Ripple P-P 10 % or less
Current consumption 100 mA or less (excluding light curtain)
Fuse (rating) Built-in electronic fuse, Triggering current: 0.5 A or more, Reset after power down
Enabling path NO contact × 3 (13-14, 23-24, 33-34)
Utilization category AC-15, DC-13 (IEC 60947-5-1)
Rated operation voltage (Ue) /
Rated operation current (le)
30 V DC / 4 A, 230 V AC / 4 A, resistive load (For inductive load, during contact protection)
Min. applicable load: 10 mA (at 24 V DC) (Note 2)
Contact resistance 100 mΩ or less (initial value)
Contact protection fuse rating
4 A (slow blow)
Pick-up delay (Auto reset / Manual reset)
80 ms or less / 90 ms or less
Response time 10 ms or less
Auxiliary output Safety relay contact (NC contact) × 1 (41-42) (Related to enabling path)
Rated operation voltage / current
24 V DC / 2 A, Min. applicable load: 10 mA (at 24 V DC)
Contact protection fuse rating
2 A (slow blow)
Semiconductor auxiliary output
(AUX)
PNP open-collector transistor
• Maximum source current: 60 mA
Output operation ON when the light curtain is interrupted
Excess voltage category II
Polarity selection function
Incorporated (Cable connection allows selection of plus / minus ground)
Minus ground: Correspond to PNP output light curtain
Plus ground: Correspond to NPN output light curtain
Pollution degree 2
Environmental
resistance
Protection Enclosure: IP40, Terminal: IP20
Ambient temperature –10 to +55 °C +14 to +131 °F (No dew condensation or icing allowed), Storage: –25 to +70 °C –13 to +158 °F
Ambient humidity 30 to 85 % RH, Storage: 30 to 90 % RH
Vibration resistance Resistance / malfunction 10 to 55 Hz frequency, 0.35 mm 0.014 in amplitude in X, Y, and Z directions for twenty times each
Enclosure material ABS
Weight Net weight: 200 g approx.
Notes: 1) Where measurement conditions have not been specified precisely, the conditions used were an
ambient temperature of +20 °C +68 °F.
2) If several SF-C13 units are being used in line together, leave a space of 5 mm 0.197 in or more
between each unit.
If the units are touching each other, reduce the rated operating current for safety output in accordance
with the ambient operating temperature as shown in the graphs at right.
3) Refer to our website for details of specifications.
0
32
35
95
40
104
45
113
50
122
55
131
Rated operation
current (A)
1
2
3
4
5
6
Ambient
temperature (°C °F)
Dilating when SF-C13 units
are mounted close together
Note 11: When the synchronization + wire (orange) and synchronization - wire (orange / black) is extended with a cable other than exclusive cable, use a 0.2
mm2 or more shielded twisted pair cable.
SF4B-C
13
SPECIFICATIONS
Handy-controller
Note: Where measurement conditions have not been specied precisely, the conditions used were an ambient temperature of +20 °C +68 °F.
Model No. SFB-HC
Item
Supply voltage 24 V DC ±10 % Ripple P-P10 % or less (common to light curtain power supply)
Current consumption 65 mA or less
Communication method RS-485 two-way communications (Specic procedure)
Digital display 4-digit red LED display × 2 (Selected beam channels, setting contents etc. are displayed.)
Function indicator Green LED × 9 (set function is displayed.)
Functions
Fixed blanking (Factory setting: Disabled) / Floating blanking (Factory setting: Disabled)
/ Auxiliary output changing (Factory setting: Negative Logic of OSSD) / Light emitting amount control (Factory setting:
Disabled)
/ Muting setting changing [Factory setting: All beam channels enabled, A = B, Setting of the muting lamp diagnosis
function enabled (Ver. 2 or later), Muting sensor output operation setting N.O. / N.O.
(Ver. 2.1 or later)]
/ Interlock setting changing (Factory setting: start / restart)
/ External device monitoring setting change (Factory setting: Enabled, 300 ms)
/ Override setting changing 60 sec. (Ver. 2.1 or later) / Setting detail monitoring /
/ Protecting (Factory setting: Disabled) (Factory password setting: 0000) / Initialization / Copy
Ambient temperature –10 to +55 °C +14 to +131 °F (No dew condensation or icing allowed), Storage: –25 to +70 °C –13 to +158 °F
Ambient humidity 30 to 85 % RH, Storage: 30 to 85 % RH
Voltage withstandability 1,000 V AC for one min. between all supply terminals connected together and enclosure
Insulation resistance 20 MΩ , or more, with 500 V DC megger between all supply terminals connected together and enclosure
Cable 8-core shielded cable, 0.5 m 1.640 ft long, with a connector at the end (2 cables)
Weight Net weight: 200 g approx.
Accessories Adapter cable: 2 cables
SF4B-C
14
I/O CIRCUIT AND WIRING DIAGRAMS
Receiver Receiver
SF4B-□CA-J05 Pigtailed type (with muting function)
I/O circuit diagrams
<In case of using I/O circuit for PNP output> <In case of using I/O circuit for NPN output>
Emitter Emitter
*S1
Switch S1
Emission halt input / Reset input
For manual reset
Vs to Vs – 2.5 V (sink current 5 mA or less): Emission halt (Note)
Open: Emission
For automatic reset
Vs to Vs – 2.5 V (sink current 5 mA or less): Emission (Note)
Open: Emission halt
Interlock setting input, Override input, Muting input A / B, External
device monitor input
Vs to Vs – 2.5 V (sink current 5 mA or less): Valid (Note)
Open: Invalid
Large multi-purpose indicator input
0 to +1.5 V (source current 5 mA or less): Lights up, Open: Turns OFF
Note: Vs is the applying supply voltage.
*S1
Switch S1
Emission halt input / Reset input
For manual reset
0 to +1.5 V (source current 5 mA or less): Emission halt
Open: Emission
For automatic reset
0 to +1.5 V (source current 5 mA or less): Emission
Open: Emission halt
Interlock setting input, Override input, Muting input A / B, External
device monitor input
0 to +1.5 V (source current: 5 mA or less): Valid, Open: Invalid
Large multi-purpose indicator input
0 to +1.5 V (source current 5 mA or less): Lights up, Open: Turns OFF
K2
K1, K2: External device
(Forced guided relay or magnetic contactor)
*S1
*S1
(Brown) +V
(Yellow) Override input
(Yellow-green / Black) Auxiliary output
(Gray) NC
(Gray) NC
(Gray / Black) Large multi-purpose
indicator input (Emitter side)
(Pink) Emission halt input /
Reset input
(Pale purple) Interlock setting input
+
24 V DC
±10 %
Load
Load
(Shield) Output polarity setting wire
(Orange / Black) Synchronization-
(Gray / Black) Large multi-purpose
indicator input (Receiver side)
(Orange) Synchronization+
(Blue) 0 V
(Red) Muting auxiliary output
*S1
(Orange / Black) Synchronization-
*S1
470 Ω
0.22 μF
470 Ω
0.047 μF
0.047 μF
0.22 μF
0.22 μF
470 Ω
*S1
Users’ circuitInternal circuit
(Orange) Synchronization+
(Brown) +V
(Sky-blue / White) Muting input A
Users’ circuitInternal circuit
(Sky-blue / Black) Muting input B
*S1
(Yellow-green) External device monitor input
(Black) Control output 1 (OSSD 1)
(White) Control output 2 (OSSD 2)
(Blue) 0 V
(Shield) Output polarity setting wire
*S1
K1 K2
1 kΩ
1 kΩ
0.22 μF
470 Ω
Sensor circuit
K1
Lead wire color of mating cable
Terminal No. of pigtailed type
Sensor circuit
K2
(Brown) +V
(Shield) Output polarity setting wire
(Red) Muting auxiliary output
(Yellow-green / Black) Auxiliary output
(Gray / Black) Large multi-purpose
indicator input (Emitter side)
+
24 V DC
±10 %
Load
Load
(Yellow) Override input
(Pale purple) Interlock setting input
(Pink) Emission halt input /
Reset input
(Orange / Black) Synchronization-
(Orange) Synchronization+
(Blue) 0 V
(Orange / Black) Synchronization-
Users’ circuitInternal circuit
(Orange) Synchronization+
(Brown) +V
(Shield) Output polarity setting wire
Users’ circuitInternal circuit
(Black) Control output 1 (OSSD 1)
(White) Control output 2 (OSSD 2)
(Gray / Black) Large multi-purpose
indicator input (Receiver side)
K1 K2
0.22 μF
(Gray) NC
K1
(Yellow-green) External device monitor input
*S1
*S1
*S1
*S1
*S1
0.047 μF
K1, K2: External device
(Forced guided relay or magnetic contactor)
470 Ω
0.22 μF
(Sky-blue / White) Muting input A
(Sky-blue / Black) Muting input B
(Blue) 0 V
470 Ω
0.22 μF
470 Ω
0.22 μF
470 Ω
0.047 μF
*S1
*S1
Lead wire color of mating cable
Terminal No. of pigtailed type
(Gray) NC
Sensor circuit Sensor circuit
1 kΩ
1 kΩ
SF4B-C
15
SF4B-CA-J05 Pigtailed type (with muting function)
I/O CIRCUIT AND WIRING DIAGRAMS
Connection examples
Muting control components: Interlock function “disabled (automatic reset)”, external device monitoring function “enabled”
The diagram at left shows the conguration when using PNP
output, interlock function “disabled (automatic reset)”
and external device monitoring function “enabled”.
<In case of using I/O circuit for PNP output>
*S1
Switch S1
Emission halt input / Reset input
For automatic reset Vs to Vs – 2.5 V (sink current 5 mA or less): Emission (Note)
Open: Emission halt
For manual reset Vs to Vs – 2.5 V (sink current 5 mA or less): Emission halt (Note)
Open: Emission
Muting input A / B, Override input
Vs to Vs – 2.5 V (sink current 5 mA or less): Valid (Note), Open: Invalid
Note: Vs is the applying supply voltage.
<In case of using I/O circuit for NPN output>
*S1
Switch S1
Emission halt input / Reset input
For automatic reset 0 to +1.5 V (source current 5 mA or less): Emission, Open: Emission halt
For manual reset 0 to +1.5 V (source current 5 mA or less): Emission halt, Open: Emission
Muting input A / B, Override input
0 to + 1.5 V (source current 5 mA or less): Valid, Open: Invalid
In case of setting the interlock function to “enabled (manual reset)”
When the interlock function is set to “Enable (manual
reset),” the override function cannot be used.
*S1 +24 V DC
(Pale purple) Interlock setting input
(Pink) Emission halt input / Reset input
Emitter
In case of setting the external device monitoring function to “disabled”
(Yellow-green) External device monitor input
(Yellow-green / Black) Auxiliary output
Emitter
Receiver
(Yellow-green) External device monitor input
(Yellow-green / Black) Auxiliary output
Emitter
Receiver
The diagram at left shows the conguration when using NPN
output, interlock function “disabled (automatic reset)”
and external device monitoring function “enabled”.
In case of setting the interlock function to “enabled (manual reset)”
When the interlock function is set to “Enable (manual
reset),” the override function cannot be used.
*S1
0 V
(Pale purple) Interlock setting input
(Pink) Emission halt input / Reset input
In case of setting the external device monitoring function to “disabled”
*S1
*S1
*S1 *S1
Gray cable
(with black line)
Gray
cable
K1 K2
(Gray) NC
(Gray / Black) Large multi-purpose indicator input (Emitter side)
(Pale purple) Interlock setting input
(Brown) +V
(Red) Muting auxiliary output
Emitter
Receiver
(Pink) Emission halt input / Reset input
(Yellow) Override input
(Yellow-green / Black) Auxiliary output
(Shield) Output polarity setting wire
(Blue) 0 V
(Orange) Synchronization+
(Orange / Black) Synchronization-
(Orange / Black) Synchronization-
(Orange) Synchronization+
(Yellow-green) External device monitor input
(Brown) +V
(Sky-blue / White) Muting input A
(Sky-blue / Black) Muting input B
(Black) Control output 1 (OSSD 1)
(White) Control output 2 (OSSD 2)
(Shield) Output polarity setting wire
(Blue) 0 V
(Gray / Black) Large multi-purpose indicator input (Receiver side)
K1, K2: External device (Forced guided relay or magnetic contactor)
(Gray) NC
Lead wire color of mating cable
+
24 V DC
±20 %
Load
Load
K1
K2
*S1*S1
(Gray) NC
(Gray / Black) Large multi-purpose indicator input (Emitter side)
(Pale purple) Interlock setting input
(Brown) +V
(Yellow-green / Black) Auxiliary output
(Shield) Output polarity setting wire
(Red) Muting auxiliary output
(Yellow) Override input
(Pink) Emission halt input / Reset input
(Blue) 0 V
(Orange) Synchronization+
(Orange / Black) Synchronization-
(Orange / Black) Synchronization-
(Orange) Synchronization+
(Yellow-green) External device monitor input
(Brown) +V
(Black) Control output 1 (OSSD 1)
(White) Control output 2 (OSSD 2)
(Shield) Output polarity setting wire
(Sky-blue / White) Muting input A
(Sky-blue / Black) Muting input B
(Blue) 0 V
(Gray / Black) Large multi-purpose indicator input (Receiver side)
(Gray) NC
K1 K2
*S1*S1
Lead wire color of mating cable
+
24 V DC
±20 %
Load
Load
K1
K2
K1, K2: External device (Forced guided relay or magnetic contactor)
Emitter
Receiver
Gray
cable
Gray cable
(with black line)
SF4B-C
16
I/O CIRCUIT AND WIRING DIAGRAMS
Receiver Receiver
SF4B-C
I/O circuit diagrams
<In case of using I/O circuit for PNP output> <In case of using I/O circuit for NPN output>
Emitter Emitter
*S1
Switch S1
Emission halt input / Reset input
For manual reset
Vs to Vs – 2.5 V (sink current 5 mA or less): Emission halt (Note)
Open: Emission
For automatic reset
Vs to Vs – 2.5 V (sink current 5 mA or less): Emission (Note)
Open: Emission halt
Interlock setting input
Vs to Vs – 2.5 V (sink current 5 mA or less): Valid (Note)
Open: Invalid
Note: Vs is the applying supply voltage.
*S1
Switch S1
Emission halt input / Reset input
For manual reset
0 to +1.5 V (source current 5 mA or less): Emission halt
Open: Emission
For automatic reset
0 to +1.5 V (source current 5 mA or less): Emission
Open: Emission halt
Interlock setting input
0 to +1.5 V (source current 5 mA or less): Valid, Open: Invalid
Cable type
K2
*S1
*S1
+
24 V DC
±10 %
Load
0.22 μF
0.22 μF
Users’ circuitInternal circuit
K1, K2: External device
(Forced guided relay or magnetic contactor)
Users’ circuitInternal circuit
K1 K2
K1
Sensor circuitSensor circuit
(Yellow-green / Black) Auxiliary output
(Pink) Emission halt input / Reset input
(Pale purple) Interlock setting input
(Brown) +V
470 Ω
470 Ω
0.22 μF
(Yellow-green) External device monitor input
(Orange / Black) Synchronization-
(Brown) +V
(Orange) Synchronization+
(Black) Control output 1 (OSSD 1)
(White) Control output 2 (OSSD 2)
470 Ω
(Shield) Output polarity setting wire
(Orange) Synchronization+
(Orange / Black) Synchronization-
(Blue) 0 V
(Blue) 0 V
(Shield) Output polarity setting wire
Lead wire color
Sensor circuitSensor circuit
K1
+
24 V DC
±10 %
Load
0.22 μF
Users’ circuitInternal circuit
K1, K2: External device
(Forced guided relay or magnetic contactor)
Users’ circuitInternal circuit
K1 K2
K2
(Brown) +V
(Shield) Output polarity setting wire
(Yellow-green / Black) Auxiliary output
(Pale purple) Interlock setting input
(Pink) Emission halt input / Reset input
470 Ω
(Blue) 0 V
0.22 μF
470 Ω
(Orange) Synchronization+
(Orange / Black) Synchronization-
(Orange / Black) Synchronization-
(Orange) Synchronization+
(Brown) +V
(Shield) Output polarity setting wire
(Blue) 0 V
(Black) Control output 1 (OSSD 1)
(White) Control output 2 (OSSD 2)
(Yellow-green) External device monitor input
0.22 μF
470 Ω
Lead wire color
*S1
*S1
SF4B-C
17
SF4B-C
I/O CIRCUIT AND WIRING DIAGRAMS
Connection examples
Interlock function “enabled (manual reset)”, external device monitoring function “enabled”
<In case of using I/O circuit for PNP output>
*S1
Switch S1
Emission halt input / Reset input
For manual reset
Vs to Vs – 2.5 V (sink current 5 mA or less): Emission halt (Note)
Open: Emission
For automatic reset
Vs to Vs – 2.5 V (sink current 5 mA or less): Emission (Note)
Open: Emission halt
Interlock setting input
Vs to Vs – 2.5 V (sink current 5 mA or less): Valid (Note)
Open: Invalid
Note: Vs is the applying supply voltage.
<In case of using I/O circuit for NPN output>
*S1
Switch S1
Emission halt input / Reset input
For manual reset
0 to +1.5 V (source current 5 mA or less): Emission halt
Open: Emission
For automatic reset
0 to +1.5 V (source current 5 mA or less): Emission
Open: Emission halt
Interlock setting input
0 to +1.5 V (source current 5 mA or less): Valid, Open: Invalid
The diagram at left shows the conguration when using PNP
output, interlock function “enabled (manual reset)” and external
device monitoring function “enabled”.
In case of setting the interlock function to “disabled (automatic reset)”
*S1
+24 V DC
Open
(Pale purple) Interlock setting input
(Pink) Emission halt input / Reset input
Emitter
In case of setting the external device monitoring function to “disabled”
The diagram at left shows the conguration when using NPN
output, interlock function “enabled (manual reset)” and external
device monitoring function “enabled”.
In case of setting the interlock function to “disabled (automatic reset)”
*S1
0 V
Open
(Pale purple) Interlock setting input
(Pink) Emission halt input / Reset input
Emitter
In case of setting the external device monitoring function to “disabled”
(Yellow-green) External device monitor input
(Yellow-green / Black) Auxiliary output
Emitter
Receiver
(Yellow-green) External device monitor input
(Yellow-green / Black) Auxiliary output
Emitter
Receiver
Cable type
K1 K2
*S1
Gray cable
(with black line)
Gray
cable
Load
K1
K2
K1, K2: External device
(Forced guided relay or magnetic contactor)
+
24 V DC
±10 %
Emitter
Receiver
Lead wire color
(Brown) +V
(Pale purple) Interlock setting input
(Pink) Emission halt input / Reset input
(Yellow-green / Black) Auxiliary output
(Shield) Output polarity setting wire
(Blue) 0 V
(Orange) Synchronization+
(Orange / Black) Synchronization-
(Orange / Black) Synchronization-
(Orange) Synchronization+
(Yellow-green) External device monitor input
(Brown) +V
(Black) Control output 1 (OSSD 1)
(White) Control output 2 (OSSD 2)
(Shield) Output polarity setting wire
(Blue) 0 V
K1 K2
*S1
Load
K1
K2
K1, K2: External device
(Forced guided relay or magnetic contactor)
+
24 V DC
±10 %
Gray cable
(with black line)
Gray
cable
Emitter
Receiver
Lead wire color
(Brown) +V
(Yellow-green / Black) Auxiliary output
(Shield) Output polarity setting wire
(Pink) Emission halt input / Reset input
(Pale purple) Interlock setting input
(Blue) 0 V
(Orange) Synchronization+
(Orange / Black) Synchronization-
(Orange / Black) Synchronization-
(Orange) Synchronization+
(Yellow-green) External device monitor input
(Brown) +V
(Black) Control output 1 (OSSD 1)
(White) Control output 2 (OSSD 2)
(Shield) Output polarity setting wire
(Blue) 0 V
SF4B-C
18
I/O CIRCUIT AND WIRING DIAGRAMS
SF-C13
SF4B-□C wiring diagrams (Control Category 4)
For PNP output (minus ground)
Connect the light curtain control outputs OSSD 1 and
OSSD 2 to S1 and S2 respectively.
For NPN output (plus ground)
Connect the light curtain control outputs OSSD 1 and
OSSD 2 to S4 and S2 respectively and ground the + side.
F
A1
A2 AUX
0 V
K1
K2
KB
KB
KA
KA
N
14 24 34 42
L1L2 L3
13 23 33 41
L1
SF-C13 control circuit
Ui
OUT
FAULT
INTER_LOCK
FUSE1
FUSE2
X1 X2 X3S1 S4S2 S3
RESET
(Note 1, 2)
Emitter Receiver
OSSD 2 (White)
OSSD 1 (Black)
External device monitor input (Yellow-green)
Output
polarity
setting wire
(Shield)
0 V (Blue)
Interlock setting
input (Pale purple)
Open
Auxiliary output
Emission
halt input /
Reset input
(Pink)
Output polarity
setting wire
(Shield)
0 V (Blue)
+V (Brown)
+V (Brown)
Synchronization-
(Orange / Black)
Synchronization+
(Orange)
+24 V DC
(Note 1)
Load
F.G.
3
M
Cable color: Gray
Cable color:
Gray with black line
Yellow-green
/ Black
KA, KB: External device
(Forced guided relay or magnetic contactor)
0 V
Open
3
M
F
A1
A2 AUX
F.G.
K1
K2
KB
KA
N
14 24 34 42
13 23 33 41
L1
SF-C13 control circuit
Ui
OUT
FAULT
INTER_LOCK
FUSE1
FUSE2
X1 X2 X3S1 S4S2 S3
RESET
(Note 1, 2)
KB
KA
L1L2 L3
OSSD 1 (Black)
OSSD 2 (White)
External device monitor input (Yellow-green)
Output
polarity
setting wire
(Shield)
0 V (Blue)
(Note 1)
Interlock setting
input (Pale purple)
Auxiliary output
Yellow-green
/ Black
Emission
halt input /
Reset input
(Pink)
Output polarity
setting wire
(Shield)
0 V (Blue)
+V (Brown)
+V (Brown)
Synchronization-
(Orange / Black)
Synchronization+
(Orange)
+24 V DC
Load
Emitter Receiver
Cable color: Gray
Cable color:
Gray with black line
KA, KB: External device
(Forced guided relay or magnetic contactor)
Notes: 1) The above diagram is when using manual reset. If automatic reset
is used, disconnect the lead from X2 and connect it to X3. In this
case, a reset (RESET) button is not needed.
2) Use a momentary-type switch as the reset (RESET) button.
Notes: 1) The above diagram is when using manual reset. If automatic reset
is used, disconnect the lead from X2 and connect it to X3. In this
case, a reset (RESET) button is not needed.
2) Use a momentary-type switch as the reset (RESET) button.
Terminal arrangement diagram
A1
A2
S1
S2
S3
S4
AUX
X1
X2
X3
13
14
23
24
33
34
41
42
Terminal Description
A1 +24 V DC
A2 0 V
S1 to S4 Light curtain control output (OSSD)
input terminal
AUX Semiconductor auxiliary output
X1 Reset output terminal
X2 Reset input terminal (Manual)
X3 Reset input terminal (Automatic)
13-14, 23-24, 33-34 Enabling path (NO contact × 3)
41-42 Auxiliary output (NC contact × 1)
A terminal block is required for wiring of light
curtain side.
SF4B-C
19
In case that this light curtain is used under
automatic reset mode, set the system not to be
auto reset by the safety relay unit, etc.
(conforming to EN 60204-1)
Interlock function
The selection of manual reset / automatic reset is
available by applying the interlock input (pale purple)
wiring. The interlock becomes available by selecting
manual reset.
Manual reset
The control outputs (OSSD 1, OSSD 2) are not turned
ON automatically even though this device is received the
light. When this device is reset in light received state
[open the emission halt input / reset input → short-circuit
the device to 0 V or +V → open], the control outputs
(OSSD 1, OSSD 2) are turned ON.
Automatic reset
The control outputs
(OSSD 1, OSSD 2) are
turned ON automatically
when this device
receives the light.
+24 V DC
(or 0 V)
Open
Emission halt input / Reset input (Pink)
Interlock setting input (Pale purple)
Emitter
Emission halt function
This function stops the emission process of the emitter.
You can select whether emission is on or halted by
means of the connection status for the emission halt input
/ reset input wire (pink).
During emission halt, the control outputs (OSSD 1, OSSD
2) become OFF status.
By using this function, malfunction due to extraneous
noise or abnormality in the control outputs (OSSD 1,
OSSD 2) and the auxiliary output can be determined
even from the machinery side.
Normal operation is restored when the emission halt input
/ reset input wire (pink) is connected to 0 V or +V (for
manual reset: open).
It is possible to change the conditions for interlocking by
using the handy-controller SFB-HC (optional). Refer to
instruction manual enclosed with this product for details.
In case of using the interlock function, be sure
there exists no operator inside of the
dangerous area. It causes death or serious
injury without the conrmation.
Interlock setting input wire (pale purple) Interlock function
When selecting PNP output: Connected to +V
When selecting NPN output: Connected to 0 V Manual reset
Open Automatic reset
The reset switch shall be placed in area where
all over the dangerous zone shall be
comprehend and out side of the dangerous zone.
Do not use the emission halt function for the
purpose of stopping the machine in which the
SF4B-C series is installed. Failure to do so
could result in death or serious injury.
Interlock
function
Emission halt input /
Reset input wire (pink)
Emission
halt input
Control output status
(OSSD 1, OSSD 2)
Manual
reset
Open Invalid ON
When selecting PNP output:
Connected to +V
When selecting NPN output:
Connected to 0 V
Valid OFF
Automatic
reset
Open Valid OFF
When selecting PNP output:
Connected to +V
When selecting NPN output:
Connected to 0 V
Invalid ON
PRECAUTIONS FOR PROPER USE
Refer to the instruction manual for details.
The instruction manual can be downloaded from our website.
Wiring
Refer to the applicable regulations for the
region where this device is to be used when
setting up the device. In addition, make sure
that all necessary measures are taken to
prevent possible dangerous operating errors
resulting from earth faults.
Make sure to carry out the wiring in the power supply off
condition.
Verify that the supply voltage variation is within the rating.
If power is supplied from a commercial switching
regulator, ensure that the frame ground (F.G.) terminal of
the power supply is connected to an actual ground.
In case noise generating equipment (switching regulator,
inverter motor, etc.) is used in the vicinity of this sensor,
connect the frame ground (F.G.) terminal of the
equipment to an actual ground.
Do not run the wires together with high-voltage lines or
power lines or put them in the same raceway. This can
cause malfunction due to induction.
External device monitoring function
This is the function for checking whether the external
safety relay connected to the control outputs (OSSD 1,
OSSD 2) perform normally in accordance with the control
outputs (OSSD 1, OSSD 2) or not. Monitor the contacting
point “b” of the external safety relay, and if any
abnormality such as deposit of the contacting point, etc.
is detected, change the status of the light curtain into
lockout one, and turn OFF the control outputs (OSSD 1,
OSSD 2).
In case of setting the external device monitoring function to enabled
Connect the external device monitoring input (yellow-
green) to the external safety relay connected the control
outputs (OSSD 1, OSSD 2).
In case of not using the external device monitoring function
Connect the external device monitoring input (yellow-
green) to the auxiliary output (yellow-green / black). At
this time, set the auxiliary output as [negative logic of
control outputs (OSSD 1, OSSD 2)] (factory setting).
The auxiliary output cannot be connected to external
devices.
Emitter
Auxiliary output
(Yellow-green / Black)
External device
monitor input
(Yellow-green)
Receiver
It is also possible to set the external device monitoring
function into invalid by using the handy-controller
SFB-HC (optional). Refer to instruction manual
enclosed with this product for details.
SF4B-C
20
PRECAUTIONS FOR PROPER USE
Auxiliary output (Non-safety output)
This light curtain incorporates the auxiliary output (yellow-
green / black) for the non-safety output. The auxiliary
output is incorporated with the emitter.
Do not use the auxiliary output for the purpose of
stopping the device with SF4B-C installed. Failure
to do so could result in serious injury or death.
Auxiliary output
setting
Normal mode
Lockout
Emission
halt
Control outputs
(OSSD 1, OSSD 2) status
Beam
received
Beam
interrupted
Negative logic of OSSD
(Factory setting) ON OFF ON ON
Muting Function (For SF4B-□CA-J05 only)
This function turns the safety function of this light curtain
into disabled temporarily. When the control outputs
(OSSD 1, OSSD 2) are ON, this function is available for
passing the workpiece through the sensing area of the
light curtain without stopping the machinery.
The muting function becomes valid when all the
conditions listed below are satised.
(1) The control outputs (OSSD 1, OSSD 2) shall be ON.
(2)
The output of the muting sensors A and B shall be changed
from OFF (open) to ON. At this time, the time difference
occurred by changing the output of the muting sensors A
and B into ON status shall be within 0.03 to 3 sec. (Note 1)
The following devices, photoelectric sensor with
semiconductor output, inductive proximity sensor,
position switch on N.O. (Normally open) contact, etc. are
available for applying to the muting sensor.
Notes: 1) 0 to 3 sec. is allowable by using the handy controller Ver. 2.1
(SFB-HC) (optional) and connecting N.O. (Normally Open)
type muting sensor to the input A, as well as connecting N.C.
(Normally Closed) type muting sensor to the input B.
2) The muting indicator diagnosis function can be set with the
handy controller Ver. 2 or later (SFB-HC) (optional), but it
must be set to invalid. If the muting indicator diagnosis
function is set to valid, the muting function cannot be used.
Incorrect use of the muting control may cause
accidents. Please understand the muting
control fully, and use it. As for the muting
control, the following international standards
dene the requirements.
ISO 13849-1 (EN ISO 13849-1 / JIS B 9705-1)
IEC 61496-1 (ANSI / UL 61496 / JIS B 9704-1)
IEC 60204-1 (JIS B 9960-1)
EN 415-4
ANSI B11.19-1990
ANSI/RIA R15.06-1999
Use the muting control while the machine cycle
is not in danger mode. Maintain safety with the
other measure while the muting control is
activated.
For the application that the muting control is
activated when a workpiece passes through
the sensor, place the muting sensor so that the
conditions for the muting control cannot be
satised by intrusion of personnel when the
workpiece is passing through the sensor or the
workpiece is not passing through it.
Be sure to check the operation of the muting
function before its use.
<Muting auxiliary output wiring>
(Gray / Black) Large multi-purpose indicator input (Emitter side)
(Red) Muting auxiliary output
(Brown) +V
(Blue) 0 V
(Orange) Synchronization+
(Orange / Black) Synchronization-
(Orange / Black) Synchronization-
(Orange) Synchronization+
(Brown) +V
(Blue) 0 V
(Gray / Black) Large multi-purpose indicator input (Receiver side)
+
24 V DC
±10 %
Gray
cable
Gray cable
(with black line)
Emitter
Receiver
Override function (For SF4B-□CA-J05 only)
This function sets the safety function of this light curtain
enabled forcibly. When using the muting function, the
override function can be used to start the machinery at
times such as when the control outputs (OSSD 1 and
OSSD 2) are OFF or when the muting sensors are ON
when the line is to be started. The override function
becomes valid when all the conditions listed below are
satised.
To trigger a large multi-purpose indicator during muting
operation, connect the wiring as follows: As for lead wires
other than below, perform wiring depending on your
application.
(1) The signal shall be input to either muting sensor A, B,
or A and B.
(2) The override input (yellow) shall be short-circuited to
0 V or +V, and the emission halt input / reset input
(pink) shall be opened. (3 sec. continuously)
The override function only operates when the interlock
function is disabled (automatic reset).
If one of the two conditions above becomes invalid or
timing exceeds 60 sec. (Note 1), the override function
becomes invalid.
Notes: 1) By using handy-controller (SFB-HC) (optional) Ver.2.1 or
later, a change between 60 and 600 sec. by 10 sec. per unit
is possible.
2) The muting indicator diagnosis function can be set with the
handy controller Ver. 2 or later (SFB-HC) (optional), but it
must be set to invalid. If the muting indicator diagnosis
function is set to valid, the muting function cannot be used.
3) The override function only operates when the interlock
function is disabled (automatic reset).
Make sure manually to operate system for
starting override function. Furthermore, the
system shall be placed in area where all over
the dangerous zone shall be comprehend
and out side of the dangerous zone.
Using override function, make sure that there
exist no operator in the dangerous zone,
which may result in death or serious injury.
Refer to the instruction manual for details.
The instruction manual can be downloaded from our website.
SF4B-C
21
PRECAUTIONS FOR PROPER USE
When this device is used in the “PSDI mode”, an
appropriate control circuit must be congured
between this device and the machinery. For
details, be sure to refer to the standards or
regulations applicable in each region or country.
To use this product in the U.S.A., refer to OSHA 1910.
212 and OSHA 1910. 217 for installation, and in
Europe, refer to EN 999 as well. Observe your national
and local requirements before installing this product.
This catalog is a guide to select a suitable product. Be sure to
read instruction manual attached to the product prior to its use.
Both emitter and receiver are combined adjusted on factory
setting, please apply both emitter and receiver with the same
serial No. The serial No. is indicated on the plates of both
emitter and receiver. (Indicated under model No.)
Make sure to carry out the test run before regular operation.
Do not use this product with machinery that cannot be stopped
immediately during the operating cycle by means of an
emergency stop system.
Others
Sensing area
Do not use during the initial transient time (2 sec.) after the
power supply is switched on.
Avoid dust, dirt and steam.
Take care that the light curtain does not come in direct contact
with water, oil, grease, or organic solvents, such as, thinner, etc.
Take care that the light curtain is not directly exposed to
uorescent light from a rapid-starter lamp or a high frequency
lighting device, as it may affect the sensing performance.
Make sure to install this product such that any
part of the human body must pass through its
sensing area in order to reach the dangerous
parts of the machinery. Furthermore, ensure that
some part of the operator’s body always remains
in the sensing area when operation is done with
the dangerous parts of the machine. If the human
body is not detected, there is a danger of serious
injury or death.
Do not use any reection type or recursive
reection type arrangement.
Multiple receivers (emitters) cannot be connected
to one emitter (receiver).
Example of correct installation
Dangerous
part
Sensing area Protective structure
Sensing area
Dangerous part
Example of incorrect installation
Dangerous
part
Sensing area
Sensing area
Dangerous
part
Inuence of reective surfaces
Install the light curtain by considering the effect
of nearby reective surfaces, and take
countermeasures such as painting, masking, or
changing the material of the reective surface,
etc. Failure to do so may cause the light curtain
not to detect, resulting in serious body injury or
death.
Install this device at a distance of at least A (m) (given
below) away from reective surfaces such as metal walls,
oors, ceilings, workpiece, covers, panels or glass
surfaces.
Side view Top view
Reflective ceiling
Reflective floor
Sensing range
L
Emitter Receiver
A
A
Reflective surface
Sensing range
L
Emitter Receiver
A
θ
θ
Allowable installation distance A (m ft)
Sensing range L (m ft)
0
0.1
0.328
0.3
0.984
0.4
1.312
0.5
1.640
0.2
0.656
1
3.281
9
29.528
7
22.966
3
9.843
5
16.404
Install in this area
Do not install in this area
Distance
between
emitter and
receiver
Setting
distance L
Allowable
installation
distance A
0.3 to 3 m
0.984 to
9.843 ft
0.16 m 0.525 ft
3 to 7 m
9.843 to
22.966 ft
L/2 × tan2θ =
L/2 × 0.105 (m)
0.344 (ft) (θ = 3°)
Note: The effective aperture angle for this device is ±2.5° or less
(when L > 3 m 9.843 ft) as required by IEC 61496-2, ANSI/UL
61496-2. However, install this device away from reective
surfaces considering an effective aperture angle of ±3° to take
care of beam misalignment, etc. during installation.
Handy-controller
This device enables to set each function using
the handy-controller SFB-HC (optional).
Among the functions, the contents related to
the safety distance such as the size of the
minimum sensing object and response time are
varied depending on the setting condition.
When setting each function, re-calculate the
safety distance, and make enough space
larger than the calculated safety distance.
Failure to do so might cause the accident that
the device cannot stop quickly before reaching
the dangerous area of the machinery, resulting
in the serious injury or death.
Refer to the instruction manual enclosed with the
handy-controller for details of the function settings for
using handy-controller SFB-HC (optional).
Refer to the instruction manual for details.
The instruction manual can be downloaded from our website.
SF4B-C
22
PRECAUTIONS FOR PROPER USE
Calculate the safety distance correctly, and
always maintain a distance which is equal to
or greater than the safety distance, between
the sensing area of this light curtain and the
dangerous parts of the machinery. (Please
check the latest standards for the equation.)
If the safety distance is miscalculated or if
sufcient distance is not maintained, there is
a danger of serious injury or death.
Before designing the system, refer to the
relevant standards of the region where this
device is to be used and then install this
device.
Emitter
Receiver
S: Safety distance
S
Dangerous part
of machine
Beam axis
The sizes of the minimum sensing objects for
this device vary depending on whether or not
the oating blanking function is being used.
Calculate the safety distance with the proper
size of the minimum sensing object and
appropriate equation.
Size of minimum sensing object when applying oating blanking
function
Invalid
Setting (Note)
1 beam
channel
2 beam
channels
3 beam
channels
SF4B-H□C (A-J05)
Min. sensing object
ø25 mm ø0.984 in
ø25 mm
ø0.984 in
ø45 mm
ø1.772 in
ø65 mm
ø2.559 in
ø85 mm
ø3.346 in
SF4B-H□C (A-J05)
Min. sensing object
ø45 mm ø1.772 in
ø45 mm
ø1.772 in
ø85 mm
ø3.346 in
ø125 mm
ø4.921 in
ø165 mm
ø6.496 in
Note: Refer to p. 5 for details of the floating blanking function.
For use in Europe (EU) (as EN 999) (Also applicable to ISO 13855 / JIS B 9715)
For intrusion direction perpendicular to the sensing area
<In the case that the minimum sensing object is ø40 mm ø1.575 in or less>
Equation S = K × T + C
S: Safety distance (mm)
Minimum required distance between the sensing area
surface and the dangerous parts of the machine
K:
Intrusion velocity of operator’s body or object (mm/sec.)
Taken as 2,000 (mm/sec.) for calculation
T: Response time of total equipment (sec.)
T = Tm + TSF4B
Tm: Maximum halting time of machinery (sec.)
TSF4B: Response time of the SF4B-C series (sec.)
C: Additional distance calculated from the size of the
minimum sensing object of the SF4B-C series (mm)
However, the value of “C” cannot be under 0.
C = 8 × (d - 14)
d: Minimum sensing object diameter (mm)
Safety distance is calculated based on the following
equation when a person moves perpendicular (normal
intrusion) to the sensing area of the light curtain.
In case the intrusion direction is not perpendicular to the
sensing area, be sure to refer to the relevant standard
(regional standard, specication of the machine, etc.) for
details of the calculation.
For calculating the safety distance “S”, there are the
following ve cases.
First calculate by substituting the value K = 2,000
(mm/sec.) in the equation above. Then, classify the
obtained value of “S” into three cases, 1) S < 100, 2)
100 ≤ S ≤ 500, and 3) S > 500. For Case
3) S > 500, recalculate by substituting the value K =
1,600 (mm/sec.). After that, classify the calculation
result into two cases,
4) S ≤ 500 and 5) S > 500. For details, refer to the
instruction manual enclosed with this product.
When this product is used in the “PSDI mode”, an
appropriate safety distance “S” must be calculated.
For details, be sure to refer to the standards or
regulations applicable in each region or country.
<In the case that the minimum sensing object is ø40 mm ø1.575 in or more>
Equation S = K × T + C
S: Safety distance (mm)
K:
Intrusion velocity of operator’s body or object (mm/sec.)
Taken as 1,600 (mm/sec.) for calculation
T: Response time of total equipment (sec.)
T = Tm + TSF4B
Tm: Maximum halting time of machinery (sec.)
TSF4B: Response time of the SF4B-C series (sec.)
C: Additional distance calculated from the size of the
minimum sensing object of the SF4B-C series (mm)
C = 850 (mm) (Constant)
Equation S = K × (TS + TC + TSF4B + Tbm) + Dpf
S: Safety distance (mm)
Minimum required distance between the sensing area
surface and the dangerous parts of the machine
K: Intrusion velocity {Recommended value in OSHA is
63 (inch/s) [≈ 1,600 (mm/sec.)] }
ANSI/RIA 15.06 does not dene the intrusion speed
“K”. When determining K, consider possible factors
including physical ability of operators.
TS: Halting time calculated from the operation time of the
control element (air valve, etc.) (sec.)
TC: Maximum response time of the control circuit required
for functioning the brake (sec.)
TSF4B: Response time of the SF4B-C series (sec.)
Tbm: Additional halting time tolerance for the brake
monitor (sec.)
The following equation holds when the machine is
equipped with a brake monitor.
Tbm = Ta - (TS + TC)
Ta: Setting time of brake monitor (sec.)
When the machine is not equipped with a brake
monitor, it is recommended that 20 % or more of (TS
+ TC) is taken as additional halting time.
Dpf: Additional distance calculated from the size of the
minimum sensing object of the device (mm)
SF4B-H□C (A-J05): Dpf = 61.2 mm 2.409 in
SF4B-A□C (A-J05): Dpf = 129.2 mm 5.087 in
Dpf = 3.4 × (d - 0.276) (inch)
≈ 3.4 × (d - 7) (mm)
d: Minimum sensing object diameter 0.985 (inch) ≈ 25 (mm)
[SF4B-H□C (A-J05)]
Minimum sensing object diameter 1.772 (inch) ≈ 45 (mm)
[SF4B-A□C (A-J05)]
For use in the United States of America (as per ANSI/RIA 15.06)
When the floating blanking function is applied, the
minimum sensing object becomes large. According to
ANSI/RIA 15.06,
Dpf = 900 mm (3 ft) when d > 64 mm (2.5 inches).
Safety distance
Refer to the instruction manual for details.
The instruction manual can be downloaded from our website.
SF4B-C
23
SF4B-□CA-J05 SF4B-□C
Assembly dimensions
The gure depicts rear mounting using the standard mounting bracket MS-SF4BC-1 (optional) and the intermediate supporting bracket for
standard mounting bracket MS-SF4BC-5 (optional).
<Connector of the pigtailed type (with muting function) SF4B-□CA-J05>
Model No. A B C DE F
SF4B-H□C (A-J05)SF4B-A□C (A-J05)
SF4B-H12C (A-J05)294.4
11.591
279
10.984
263.4
10.370 220 8.661
SF4B-H16C (A-J05)SF4B-A8C (A-J05)374.4
14.740
359
14.134
343.4
13.520 300 11.811 280 11.024
SF4B-H20C (A-J05)454.4
17.890
439
17.283
423.4
16.669 380 14.961
SF4B-H24C (A-J05)SF4B-A12C (A-J05)534.4
21.039
519
20.433
503.4
19.819 460 18.110 440 17.323
SF4B-H28C (A-J05)614.4
24.189
599
23.583
583.4
22.969 540 21.260
SF4B-H32C (A-J05)SF4B-A16C (A-J05)694.4
27.339
679
26.732
663.4
26.118 620 24.409 600 23.622
SF4B-H36C (A-J05)774.4
30.488
759
29.882
743.4
29.268 700 27.559
SF4B-H40C (A-J05)SF4B-A20C (A-J05)854.4
33.638
839
33.031
823.4
32.417 780 30.709 760 29.921 395
15.551
SF4B-H48C (A-J05)SF4B-A24C (A-J05)1,014.4
39.937
999
39.331
983.4
38.717 940 37.008 920 36.220 475
18.701
SF4B-H56C (A-J05)SF4B-A28C (A-J05)1,174.4
46.236
1,159
45.630
1,143.4
45.016 1,100 43.307 1,080 42.520 555
21.850
SF4B-H64C (A-J05)SF4B-A32C (A-J05)1,334.4
52.535
1,319
51.929
1,303.4
51.315 1,260 49.606 1,240 48.819 415
16.339
854
33.622
SF4B-H72C (A-J05)SF4B-A36C (A-J05)1,494.4
58.835
1,479
58.228
1,463.4
57.614 1,420 55.906 1,400 55.118 468
18.425
961
37.835
SF4B-H80C (A-J05)SF4B-A40C (A-J05)1,654.4
65.134
1,639
64.528
1,623.4
63.913 1,580 62.205 1,560 61.417 521
20.512
1,068
42.047
SF4B-H88C (A-J05)SF4B-A44C (A-J05)1,814.4
71.433
1,799
70.827
1,783.4
70.212 1,740 68.504 1,720 67.716 574
22.598
1,175
46.260
SF4B-H96C (A-J05)SF4B-A48C (A-J05)1,974.4
77.732
1,959
77.126
1,943.4
76.512 1,900 74.803 1,880 74.016 627
24.685
1,282
50.472
Model No. G H
SF4B-H□C (A-J05)21.7 0.854 20 0.787
SF4B-A□C (A-J05)41.7 1.642 40 1.575
DIMENSIONS (Unit: mm in)
5
0.197
5
0.197
27.4
1.079
27.4
1.079
19.6
0.772 19.6
0.772
(3.2 0.126)
(2 0.079)
33
1.299
33
1.299
H
2 0.079
2
0.079
2 0.079 2 0.079
10.7 0.421
10.7
0.421
21.6 0.850 21.6 0.850
11.8 0.465
29.9
1.177
29.9
1.177
10 0.394 10 0.394
20 0.787
B
F
E
5.4 0.213
5.4 0.213
MS-SF4BC-1
MS-SF4BC-5
(46.6 1.835)
G
H
ø5 ø0.197
Gray cable
(with black line)
ø5 ø0.197 Gray cable
ø15.6 ø0.614
D
G
(46.6 1.835)
D
5.4
0.213
F
E
20 0.787
B
Beam pitch
Protective height
11.8 0.465
C C
AA
5.4 0.213
(45 1.772)
6 × M3 mounting hole
for countersunk screw
2
0.079
2
0.079
120
4.724
120
4.724
108
4.252
108
4.252
2
0.079
3.2
0.126
5
0.197
5
0.197
27.4
1.079
27.4
1.079
19.6
0.772 19.6
0.772
(3.2 0.126)
(2 0.079)
33
1.299
33
1.299
H
2 0.079
2
0.079
2 0.079 2 0.079
10.7 0.421
10.7
0.421
21.6 0.850 21.6 0.850
11.8 0.465
29.9
1.177
29.9
1.177
10 0.394 10 0.394
20 0.787
B
F
E
5.4 0.213
5.4 0.213
MS-SF4BC-1
MS-SF4BC-5
(46.6 1.835)
G
H
ø5 ø0.197
Gray cable
(with black line)
ø5 ø0.197 Gray cable
ø15.6 ø0.614
D
G
(46.6 1.835)
D
5.4
0.213
F
E
20 0.787
B
Beam pitch
Protective height
11.8 0.465
C C
AA
5.4 0.213
(45 1.772)
6 × M3 mounting hole
for countersunk screw
2
0.079
2
0.079
120
4.724
120
4.724
108
4.252
108
4.252
2
0.079
3.2
0.126
Emitter Receiver
Light curtain
The CAD data in the dimensions can be downloaded from our website.
SF4B-C
24
Model No. A B C DJ K
SF4B-H□C (A-J05)SF4B-A□C (A-J05)
SF4B-H12C (A-J05)294.4
11.591
279
10.984
263.4
10.370 220 8.661
SF4B-H16C (A-J05)SF4B-A8C (A-J05)374.4
14.740
359
14.134
343.4
13.520 300 11.811 280 11.024
SF4B-H20C (A-J05)454.4
17.890
439
17.283
423.4
16.669 380 14.961
SF4B-H24C (A-J05)SF4B-A12C (A-J05)534.4
21.039
519
20.433
503.4
19.819 460 18.110 440 17.323
SF4B-H28C (A-J05)614.4
24.189
599
23.583
583.4
22.969 540 21.260
SF4B-H32C (A-J05)SF4B-A16C (A-J05)694.4
27.339
679
26.732
663.4
26.118 620 24.409 600 23.622
SF4B-H36C (A-J05)774.4
30.488
759
29.882
743.4
29.268 700 27.559
SF4B-H40C (A-J05)SF4B-A20C (A-J05)854.4
33.638
839
33.031
823.4
32.417 780 30.709 760 29.921 390
15.354
SF4B-H48C (A-J05)SF4B-A24C (A-J05)1,014.4
39.937
999
39.331
983.4
38.717 940 37.008 920 36.220 470
18.504
SF4B-H56C (A-J05)SF4B-A28C (A-J05)1,174.4
46.236
1,159
45.630
1,143.4
45.016 1,100 43.307 1,080 42.520 550
21.654
SF4B-H64C (A-J05)SF4B-A32C (A-J05)1,334.4
52.535
1,319
51.929
1,303.4
51.315 1,260 49.606 1,240 48.819 410
16.142
849
33.425
SF4B-H72C (A-J05)SF4B-A36C (A-J05)1,494.4
58.835
1,479
58.228
1,463.4
57.614 1,420 55.906 1,400 55.118 463
18.228
956
37.638
SF4B-H80C (A-J05)SF4B-A40C (A-J05)1,654.4
65.134
1,639
64.528
1,623.4
63.913 1,580 62.205 1,560 61.417 516
20.315
1,063
41.850
SF4B-H88C (A-J05)SF4B-A44C (A-J05)1,814.4
71.433
1,799
70.827
1,783.4
70.212 1,740 68.504 1,720 67.716 569
22.402
1,170
46.063
SF4B-H96C (A-J05)SF4B-A48C (A-J05)1,974.4
77.732
1,959
77.126
1,943.4
76.512 1,900 74.803 1,880 74.016 622
24.488
1,277
50.275
Model No. G H
SF4B-H□C (A-J05)21.7 0.854 20 0.787
SF4B-A□C (A-J05)41.7 1.642 40 1.575
SF4B-□CA-J05 SF4B-□C
Assembly dimensions
The gure depicts side mounting using the standard mounting bracket MS-SF4BC-1 (optional) and the intermediate supporting bracket for
standard mounting bracket MS-SF4BC-5 (optional).
<Connector of the pigtailed type (with muting function) SF4B-□CA-J05>
J
20
0.787
25
0.984
20 0.787
15 0.591
27.4
1.079
27.4
1.079
27.4
1.079
27.4
1.079
19.6
0.772 19.6
0.772
(2 0.079)(2 0.079)
H
2 0.079 2 0.079
10.7 0.421
10.7 0.421
21.6 0.850
11.8 0.465
21.6 0.850
11.8 0.465
29.9
1.177
29.9
1.177
10 0.394 10
0.394
5 0.197 5 0.197
5 0.197
5 0.197
B
K
D
(46.6 1.835)
108
4.252 108
4.252
G
A
CCA
H
G
DB
K
J
20 0.787
15 0.591
20
0.787
25
0.984
ø15.6 ø0.614
ø5 ø0.197
Gray cable
(with black line)
ø5 ø0.197 Gray cable
Beam
pitch
MS-SF4BC-5
MS-SF4BC-1
Protective
height
5.4 0.213
(46.6 1.835)
(3 0.118)
(2 0.079)(2 0.079)
5.4 0.213
(45 1.772)
6 × M3 mounting hole
for countersunk screw
3
0.118
120
4.724 120
4.724
J
20
0.787
25
0.984
20 0.787
15 0.591
27.4
1.079
27.4
1.079
27.4
1.079
27.4
1.079
19.6
0.772 19.6
0.772
(2 0.079)(2 0.079)
H
2 0.079 2 0.079
10.7 0.421
10.7 0.421
21.6 0.850
11.8 0.465
21.6 0.850
11.8 0.465
29.9
1.177
29.9
1.177
10 0.394 10
0.394
5 0.197 5 0.197
5 0.197
5 0.197
B
K
D
(46.6 1.835)
108
4.252 108
4.252
G
A
CCA
H
G
DB
K
J
20 0.787
15 0.591
20
0.787
25
0.984
ø15.6 ø0.614
ø5 ø0.197
Gray cable
(with black line)
ø5 ø0.197 Gray cable
Beam
pitch
MS-SF4BC-5
MS-SF4BC-1
Protective
height
5.4 0.213
(46.6 1.835)
(3 0.118)
(2 0.079)(2 0.079)
5.4 0.213
(45 1.772)
6 × M3 mounting hole
for countersunk screw
3
0.118
120
4.724 120
4.724
Emitter Receiver
Light curtain
The CAD data in the dimensions can be downloaded from our website.
DIMENSIONS (Unit: mm in)
SF4B-C
25
Model No. B DL M N P
SF4B-H□C (A-J05)SF4B-A□C (A-J05)
SF4B-H12C (A-J05)279
10.984 220 8.661
316.4
12.457
264.4
10.409
SF4B-H16C (A-J05)SF4B-A8C (A-J05)359
14.134 300 11.811 280 11.024 396.4
15.606
344.4
13.559
SF4B-H20C (A-J05)439
17.283 380 14.961
476.4
18.756
424.4
16.709
SF4B-H24C (A-J05)SF4B-A12C (A-J05)519
20.433 460 18.110 440 17.323 556.4
21.906
504.4
19.858
SF4B-H28C (A-J05)599
23.583 540 21.260
636.4
25.055
584.4
23.008
SF4B-H32C (A-J05)SF4B-A16C (A-J05)679
26.732 620 24.409 600 23.622 716.4
28.205
664.4
26.157
SF4B-H36C (A-J05)759
29.882 700 27.559
796.4
31.354
744.4
29.307
SF4B-H40C (A-J05)SF4B-A20C (A-J05)839
33.031 780 30.709 760 29.921 876.4
34.504
824.4
32.457
399.5
15.728
SF4B-H48C (A-J05)SF4B-A24C (A-J05)999
39.331 940 37.008 920 36.220 1,036.4
40.803
984.4
38.756
479.5
18.878
SF4B-H56C (A-J05)SF4B-A28C (A-J05)1,159
45.630 1,100 43.307 1,080 42.520 1,196.4
47.102
1,144.4
45.055
559.5
22.028
SF4B-H64C (A-J05)SF4B-A32C (A-J05)1,319
51.929 1,260 49.606 1,240 48.819 1,356.4
53.402
1,304.4
51.354
419.5
16.516
858.5
33.799
SF4B-H72C (A-J05)SF4B-A36C (A-J05)1,479
58.228 1,420 55.906 1,400 55.118 1,516.4
59.701
1,464.4
57.654
472.5
18.602
965.5
38.012
SF4B-H80C (A-J05)SF4B-A40C (A-J05)1,639
64.528 1,580 62.205 1,560 61.417 1,676.4
66.000
1,624.4
63.953
525.5
20.689
1,072.5
42.224
SF4B-H88C (A-J05)SF4B-A44C (A-J05)1,799
70.827 1,740 68.504 1,720 67.716 1,836.4
72.299
1,784.4
70.252
578.5
22.776
1,179.5
46.437
SF4B-H96C (A-J05)SF4B-A48C (A-J05)1,959
77.126 1,900 74.803 1,880 74.016 1,996.4
78.598
1,944.4
76.551
631.5
24.862
1,286.5
50.650
Model No. H Q
SF4B-H□C (A-J05)20 0.787 22.2 0.874
SF4B-A□C (A-J05)40 1.575 42.2 1.661
SF4B-□CA-J05 SF4B-□C
Assembly dimensions
The gure depicts rear mounting using the rear utility mounting bracket MS-SF4BC-2 (optional) and the intermediate supporting bracket for
utility mounting bracket MS-SF4BC-4 (optional).
<Connector of the pigtailed type (with muting function) SF4B-□CA-J05>
(4.2 0.165)
(4.2 0.165)(4.2 0.165)
(4.2 0.165)
4
0.157 4
0.157
8 0.315 8 0.315
10.6 0.417
10.6 0.417
19.6
0.772
19.6
0.772
19.6
0.772
19.6
0.772
10.8
0.425
10.8
0.425
32.2
1.268
32.2
1.268
23.8
0.937
23.8
0.937
10 0.394 10 0.394
MS-SF4BC-2
ø5 ø0.197 Gray cable
(with black line)
Beam pitch
Protective
height
ø5 ø0.197 Gray cable
ø15.6 ø0.614
5.4 0.213
5.4 0.213
MS-SF4BC-4
5.4 0.213
5.4 0.213
B
P
N
D
L
Q
H
M
(46.6 1.835)
D
Q
H
ML
(46.6 1.835)
B
P
N
(45 1.772)
108
4.252 108
4.252
120
4.724
120
4.724
(4.2 0.165)
(4.2 0.165)(4.2 0.165)
(4.2 0.165)
4
0.157 4
0.157
8 0.315 8 0.315
10.6 0.417
10.6 0.417
19.6
0.772
19.6
0.772
19.6
0.772
19.6
0.772
10.8
0.425
10.8
0.425
32.2
1.268
32.2
1.268
23.8
0.937
23.8
0.937
10 0.394 10 0.394
MS-SF4BC-2
ø5 ø0.197 Gray cable
(with black line)
Beam pitch
Protective
height
ø5 ø0.197 Gray cable
ø15.6 ø0.614
5.4 0.213
5.4 0.213
MS-SF4BC-4
5.4 0.213
5.4 0.213
B
P
N
D
L
Q
H
M
(46.6 1.835)
D
Q
H
ML
(46.6 1.835)
B
P
N
(45 1.772)
108
4.252 108
4.252
120
4.724
120
4.724
Emitter Receiver
Light curtain
The CAD data in the dimensions can be downloaded from our website.
DIMENSIONS (Unit: mm in)
SF4B-C
26
Model No. DM R S T U
SF4B-H□C (A-J05)SF4B-A□C (A-J05)
SF4B-H12C (A-J05) 220 8.661
264.4
10.409
245.8
9.677
270.4
10.646
SF4B-H16C (A-J05)SF4B-A8C (A-J05) 300 11.811 280 11.024 344.4
13.559
325.8
12.827
350.4
13.795
SF4B-H20C (A-J05) 380 14.961
424.4
16.709
405.8
17.748
430.4
16.945
SF4B-H24C (A-J05)SF4B-A12C (A-J05) 460 18.110 440 17.323 504.4
19.858
485.8
19.126
510.4
20.094
SF4B-H28C (A-J05) 540 21.260
584.4
23.008
565.8
22.276
590.4
23.244
SF4B-H32C (A-J05)SF4B-A16C (A-J05) 620 24.409 600 23.622 664.4
26.157
645.8
25.425
670.4
26.394
SF4B-H36C (A-J05) 700 27.559
744.4
29.307
725.8
28.575
750.4
29.543
SF4B-H40C (A-J05)SF4B-A20C (A-J05) 780 30.709 760 29.921 824.4
32.457
805.8
31.724
382.9
15.075
830.4
32.693
SF4B-H48C (A-J05)SF4B-A24C (A-J05) 940 37.008 920 36.220 984.4
38.756
965.8
38.024
462.9
18.224
990.4
38.992
SF4B-H56C (A-J05)SF4B-A28C (A-J05) 1,100 43.307 1,080 42.520 1,144.4
45.055
1,125.8
44.323
542.9
21.374
1,150.4
45.291
SF4B-H64C (A-J05)SF4B-A32C (A-J05) 1,260 49.606 1,240 48.819 1,304.4
51.354
1,285.8
50.622
402.9
15.862
841.9
33.146
1,310.4
51.590
SF4B-H72C (A-J05)SF4B-A36C (A-J05) 1,420 55.906 1,400 55.118 1,464.4
57.654
1,445.8
56.921
455.9
17.949
948.9
37.358
1,470.4
57.890
SF4B-H80C (A-J05)SF4B-A40C (A-J05) 1,580 62.205 1,560 61.417 1,624.4
63.953
1,605.8
63.220
508.9
20.035
1,055.9
41.571
1,630.4
64.189
SF4B-H88C (A-J05)SF4B-A44C (A-J05) 1,740 68.504 1,720 67.716 1,784.4
70.252
1,765.8
69.520
561.9
22.122
1,162.9
45.783
1,790.4
70.488
SF4B-H96C (A-J05)SF4B-A48C (A-J05) 1,900 74.803 1,880 74.016 1,944.4
76.551
1,925.8
75.819
614.9
24.209
1,269.9
49.996
1,950.4
76.787
Model No. H Q
SF4B-H□C (A-J05)20 0.787 22.2 0.874
SF4B-A□C (A-J05)40 1.575 42.2 1.661
SF4B-□CA-J05 SF4B-□C
Assembly dimensions
The gure depicts space-saving mounting using the rear utility mounting bracket MS-SF4BC-2 (optional) and the intermediate supporting
bracket for utility mounting bracket MS-SF4BC-4 (optional).
<Connector of the pigtailed type (with muting function) SF4B-□CA-J05>
Emitter Receiver
Light curtain
The CAD data in the dimensions can be downloaded from our website.
DIMENSIONS (Unit: mm in)
R
T
SS
(4.2 0.165)
(4.2 0.165)
DD
QQ
HH
MM
UU
4
0.157
4
0.157
8 0.315 8 0.315
10.6 0.417 10.6 0.417
19.6
0.772
19.6
0.772 19.6
0.772
19.6
0.772
32.2
1.268
32.2
1.268
23.8
0.937
23.8
0.937
10 0.394 14 0.551 14 0.551 10 0.394
R
T
ø5 ø0.197 Gray cable
(with black line)
Beam pitch
Protective
height
ø5 ø0.197 Gray cable
5.4 0.213
5.4 0.213
(47.1 1.854)
(47.1 1.854)
5.4 0.213
5.4 0.213
ø15.6 ø0.614
(45 1.772)
MS-SF4BC-2
MS-SF4BC-4
108
4.252
108
4.252
120
4.724 120
4.724
4.2
0.165
10.8
0.425
4.2
0.165
10.8
0.425
R
T
SS
(4.2 0.165)
(4.2 0.165)
DD
QQ
HH
MM
UU
4
0.157
4
0.157
8 0.315 8 0.315
10.6 0.417 10.6 0.417
19.6
0.772
19.6
0.772 19.6
0.772
19.6
0.772
32.2
1.268
32.2
1.268
23.8
0.937
23.8
0.937
10 0.394 14 0.551 14 0.551 10 0.394
R
T
ø5 ø0.197 Gray cable
(with black line)
Beam pitch
Protective
height
ø5 ø0.197 Gray cable
5.4 0.213
5.4 0.213
(47.1 1.854)
(47.1 1.854)
5.4 0.213
5.4 0.213
ø15.6 ø0.614
(45 1.772)
MS-SF4BC-2
MS-SF4BC-4
108
4.252
108
4.252
120
4.724 120
4.724
4.2
0.165
10.8
0.425
4.2
0.165
10.8
0.425
SF4B-C
27
Model No. B DL M N P
SF4B-H□C (A-J05)SF4B-A□C (A-J05)
SF4B-H12C (A-J05)279
10.984 220 8.661
316.4
12.457
264.4
10.409
SF4B-H16C (A-J05)SF4B-A8C (A-J05)359
14.134 300 11.811 280 11.024 396.4
15.606
344.4
13.559
SF4B-H20C (A-J05)439
17.283 380 14.961
476.4
18.756
424.4
16.709
SF4B-H24C (A-J05)SF4B-A12C (A-J05)519
20.433 460 18.110 440 17.323 556.4
21.906
504.4
19.858
SF4B-H28C (A-J05)599
23.583 540 21.260
636.4
25.055
584.4
23.008
SF4B-H32C (A-J05)SF4B-A16C (A-J05)679
26.732 620 24.409 600 23.622 716.4
28.205
664.4
26.157
SF4B-H36C (A-J05)759
29.882 700 27.559
796.4
31.354
744.4
29.307
SF4B-H40C (A-J05)SF4B-A20C (A-J05)839
33.031 780 30.709 760 29.921 876.4
34.504
824.4
32.457
399.5
15.728
SF4B-H48C (A-J05)SF4B-A24C (A-J05)999
39.331 940 37.008 920 36.220 1,036.4
40.803
984.4
38.756
479.5
18.878
SF4B-H56C (A-J05)SF4B-A28C (A-J05)1,159
45.630 1,100 43.307 1,080 42.520 1,196.4
47.102
1,144.4
45.055
559.5
22.028
SF4B-H64C (A-J05)SF4B-A32C (A-J05)1,319
51.929 1,260 49.606 1,240 48.819 1,356.4
53.402
1,304.4
51.354
419.5
16.516
858.5
33.799
SF4B-H72C (A-J05)SF4B-A36C (A-J05)1,479
58.228 1,420 55.906 1,400 55.118 1,516.4
59.701
1,464.4
57.654
472.5
18.602
965.5
38.012
SF4B-H80C (A-J05)SF4B-A40C (A-J05)1,639
64.528 1,580 62.205 1,560 61.417 1,676.4
66.000
1,624.4
63.953
525.5
20.689
1,072.5
42.224
SF4B-H88C (A-J05)SF4B-A44C (A-J05)1,799
70.827 1,740 68.504 1,720 67.716 1,836.4
72.299
1,784.4
70.252
578.5
22.776
1,179.5
46.437
SF4B-H96C (A-J05)SF4B-A48C (A-J05)1,959
77.126 1,900 74.803 1,880 74.016 1,996.4
78.598
1,944.4
76.551
631.5
24.862
1,286.5
50.650
Model No. H Q
SF4B-H□C (A-J05)20 0.787 22.2 0.874
SF4B-A□C (A-J05)40 1.575 42.2 1.661
SF4B-□CA-J05 SF4B-□C
Assembly dimensions
The figure depicts side mounting using the side utility mounting bracket MS-SF4BC-3 (optional) and the intermediate supporting bracket for
utility mounting bracket MS-SF4BC-4 (optional).
<Connector of the pigtailed type (with muting function) SF4B-□CA-J05>
Emitter Receiver
Light curtain
The CAD data in the dimensions can be downloaded from our website.
DIMENSIONS (Unit: mm in)
ø15.6 ø0.614
(45 1.772)
N
(1.3 0.051)
H
Q
5
0.197
10 0.394
31.5 1.240
34.3 1.350
(12.9 0.508)
19.6 0.772
28.7
1.130
8.7 0.343
2.3 0.091
27.4 1.079
D
ML
ø5 ø0.197 Gray cable
(with black line)
B
P
5.4 0.213
5.4
0.213
(47.1 1.854)
ø5 ø0.197 Gray cable
(1.3 0.051)
H
Q
5 0.197
10 0.394
31.5 1.240
34.3 1.350
19.6 0.772
28.7
1.130
8.7 0.343
2.3 0.091
27.4 1.079
22.7 0.894 22.7 0.894
D
B
P
N
ML
5.4 0.213
MS-SF4BC-4
MS-SF4BC-3
(47.1 1.854)
Beam pitch
Protective
height
5.4 0.213
108
4.252
12.9
0.508
12.9
0.508
12.9
0.508
108
4.252
120
4.724
120
4.724
ø15.6 ø0.614
(45 1.772)
N
(1.3 0.051)
H
Q
5
0.197
10 0.394
31.5 1.240
34.3 1.350
(12.9 0.508)
19.6 0.772
28.7
1.130
8.7 0.343
2.3 0.091
27.4 1.079
D
ML
ø5 ø0.197 Gray cable
(with black line)
B
P
5.4 0.213
5.4
0.213
(47.1 1.854)
ø5 ø0.197 Gray cable
(1.3 0.051)
H
Q
5 0.197
10 0.394
31.5 1.240
34.3 1.350
19.6 0.772
28.7
1.130
8.7 0.343
2.3 0.091
27.4 1.079
22.7 0.894 22.7 0.894
D
B
P
N
ML
5.4 0.213
MS-SF4BC-4
MS-SF4BC-3
(47.1 1.854)
Beam pitch
Protective
height
5.4 0.213
108
4.252
12.9
0.508
12.9
0.508
12.9
0.508
108
4.252
120
4.724
120
4.724
SF4B-C
28
Model No. DM R S T U
SF4B-H□C (A-J05)SF4B-A□C (A-J05)
SF4B-H12C (A-J05) 220 8.661
264.4
10.409
245.8
9.677
270.4
10.646
SF4B-H16C (A-J05)SF4B-A8C (A-J05) 300 11.811 280 11.024 344.4
13.559
325.8
12.827
350.4
13.795
SF4B-H20C (A-J05) 380 14.961
424.4
16.709
405.8
17.748
430.4
16.945
SF4B-H24C (A-J05)SF4B-A12C (A-J05) 460 18.110 440 17.323 504.4
19.858
485.8
19.126
510.4
20.094
SF4B-H28C (A-J05) 540 21.260
584.4
23.008
565.8
22.276
590.4
23.244
SF4B-H32C (A-J05)SF4B-A16C (A-J05) 620 24.409 600 23.622 664.4
26.157
645.8
25.425
670.4
26.394
SF4B-H36C (A-J05) 700 27.559
744.4
29.307
725.8
28.575
750.4
29.543
SF4B-H40C (A-J05)SF4B-A20C (A-J05) 780 30.709 760 29.921 824.4
32.457
805.8
31.724
382.9
15.075
830.4
32.693
SF4B-H48C (A-J05)SF4B-A24C (A-J05) 940 37.008 920 36.220 984.4
38.756
965.8
38.024
462.9
18.224
990.4
38.992
SF4B-H56C (A-J05)SF4B-A28C (A-J05) 1,100 43.307 1,080 42.520 1,144.4
45.055
1,125.8
44.323
542.9
21.374
1,150.4
45.291
SF4B-H64C (A-J05)SF4B-A32C (A-J05) 1,260 49.606 1,240 48.819 1,304.4
51.354
1,285.8
50.622
402.9
15.862
841.9
33.146
1,310.4
51.590
SF4B-H72C (A-J05)SF4B-A36C (A-J05) 1,420 55.906 1,400 55.118 1,464.4
57.654
1,445.8
56.921
455.9
17.949
948.9
37.358
1,470.4
57.890
SF4B-H80C (A-J05)SF4B-A40C (A-J05) 1,580 62.205 1,560 61.417 1,624.4
63.953
1,605.8
63.220
508.9
20.035
1,055.9
41.571
1,630.4
64.189
SF4B-H88C (A-J05)SF4B-A44C (A-J05) 1,740 68.504 1,720 67.716 1,784.4
70.252
1,765.8
69.520
561.9
22.122
1,162.9
45.783
1,790.4
70.488
SF4B-H96C (A-J05)SF4B-A48C (A-J05) 1,900 74.803 1,880 74.016 1,944.4
76.551
1,925.8
75.819
614.9
24.209
1,269.9
49.996
1,950.4
76.787
Model No. H Q
SF4B-H□C (A-J05)20 0.787 22.2 0.874
SF4B-A□C (A-J05)40 1.575 42.2 1.661
SF4B-□CA-J05 SF4B-□C
Assembly dimensions
The figure depicts space-saving mounting using the side utility mounting bracket MS-SF4BC-3 (optional) and the intermediate supporting bracket
for utility mounting bracket MS-SF4BC-4 (optional).
<Connector of the pigtailed type (with muting function) SF4B-□CA-J05>
Emitter Receiver
Light curtain
The CAD data in the dimensions can be downloaded from our website.
DIMENSIONS (Unit: mm in)
12.9
0.508
12.9
0.508
ø5 ø0.197 Gray cable
ø15.6 ø0.614
ø5 ø0.197
Gray cable
(with black line)
RR
TT
SS
(1.3 0.051)(1.3 0.051)
DD
HH
MM
UU
QQ
5 0.197
5
0.197
10 0.394 10 0.394
31.5 1.240
31.5
1.240
34.3
1.350
34.3 1.350
(12.9 0.508)
19.6 0.772 19.6 0.772
28.7
1.130
28.7
1.130
8.7 0.343 8.7 0.343
22.7
0.894
22.7
0.894
2.3 0.091
2.3
0.091
27.4 1.079 27.4
1.079
(45 1.772)
MS-SF4BC-3
MS-SF4BC-4 Protective
height
Beam pitch
5.4 0.213
5.4 0.213
(47.1 1.854)
5.4 0.213
5.4
0.213
108
4.252
12.9
0.508
120
4.724
120
4.724
108
4.252
(47.1 1.854)
12.9
0.508
12.9
0.508
ø5 ø0.197 Gray cable
ø15.6 ø0.614
ø5 ø0.197
Gray cable
(with black line)
RR
TT
SS
(1.3 0.051)(1.3 0.051)
DD
HH
MM
UU
QQ
5 0.197
5
0.197
10 0.394 10 0.394
31.5 1.240
31.5
1.240
34.3
1.350
34.3 1.350
(12.9 0.508)
19.6 0.772 19.6 0.772
28.7
1.130
28.7
1.130
8.7 0.343 8.7 0.343
22.7
0.894
22.7
0.894
2.3 0.091
2.3
0.091
27.4 1.079 27.4
1.079
(45 1.772)
MS-SF4BC-3
MS-SF4BC-4 Protective
height
Beam pitch
5.4 0.213
5.4 0.213
(47.1 1.854)
5.4 0.213
5.4
0.213
108
4.252
12.9
0.508
120
4.724
120
4.724
108
4.252
(47.1 1.854)
SF4B-C
29
MS-SF4BC-6
MS-SF4BC-7
ø5 ø0.197
Gray cable ø5 ø0.197 Gray cable
(with black line)
46.4 1.827 46.4
1.827
19.6 0.772 19.6 0.772
32.2
1.268
31.5 1.240 31.5 1.240
12.5 0.492
26 1.024
24.3
0.957
12.5 0.492
26 1.024
24.3
0.957
(47.1 1.854)(47.1 1.854)
10 0.394 10 0.394
46.4 1.827
46.4 1.827
66.4 2.614 66.4 2.614
5.4
0.213
5.4
0.213
5.4 0.213 5.4 0.213
10 0.394 10 0.394
2.3 0.091 2.3
0.091
68.7
2.705
68.7
2.705
(24 0.945) (24 0.945)
27.4 1.079 27.4 1.079
B
Q Q
H H
V VD D
P
N
B
M M
P
N
39
1.535
39
1.535
108
4.252
108
4.252
120
4.724
120
4.724
10.8
0.425
32.2
1.268
10.8
0.425
4.7
0.185
4.7
0.185
39
1.535 39
1.535
24
0.945
24
0.945
Beam pitch
Protective
height
Model No. B DM N P V
SF4B-H□C (A-J05)SF4B-A□C (A-J05)
SF4B-H12C (A-J05)279
10.984 220 8.661
264.4
10.409
308.4
12.142
SF4B-H16C (A-J05)SF4B-A8C (A-J05)359
14.134 300 11.811 280 11.024 344.4
13.559
388.4
15.291
SF4B-H20C (A-J05)439
17.283 380 14.961
424.4
16.709
468.4
18.441
SF4B-H24C (A-J05)SF4B-A12C (A-J05)519
20.433 460 18.110 440 17.323 504.4
19.858
548.4
21.591
SF4B-H28C (A-J05)599
23.583 540 21.260
584.4
23.008
628.4
24.740
SF4B-H32C (A-J05)SF4B-A16C (A-J05)679
26.732 620 24.409 600 23.622 664.4
26.157
708.4
27.890
SF4B-H36C (A-J05)759
29.882 700 27.559
744.4
29.307
788.4
31.039
SF4B-H40C (A-J05)SF4B-A20C (A-J05)839
33.031 780 30.709 760 29.921 824.4
32.457
399.5
15.728
868.4
34.189
SF4B-H48C (A-J05)SF4B-A24C (A-J05)999
39.331 940 37.008 920 36.220 984.4
38.756
479.5
18.878
1,028.4
40.488
SF4B-H56C (A-J05)SF4B-A28C (A-J05)1,159
45.630 1,100 43.307 1,080 42.520 1,144.4
45.055
559.5
22.028
1,188.4
46.787
SF4B-H64C (A-J05)SF4B-A32C (A-J05)1,319
51.929 1,260 49.606 1,240 48.819 1,304.4
51.354
419.5
16.516
858.5
33.799
1,348.4
53.087
SF4B-H72C (A-J05)SF4B-A36C (A-J05)1,479
58.228 1,420 55.906 1,400 55.118 1,464.4
57.654
472.5
18.602
965.5
38.012
1,508.4
59.386
SF4B-H80C (A-J05)SF4B-A40C (A-J05)1,639
64.528 1,580 62.205 1,560 61.417 1,624.4
63.953
525.5
20.689
1,072.5
42.224
1,668.4
65.685
SF4B-H88C (A-J05)SF4B-A44C (A-J05)1,799
70.827 1,740 68.504 1,720 67.716 1,784.4
70.252
578.5
22.776
1,179.5
46.437
1,828.4
71.984
SF4B-H96C (A-J05)SF4B-A48C (A-J05)1,959
77.126 1,900 74.803 1,880 74.016 1,944.4
76.551
631.5
24.862
1,286.5
50.650
1,988.4
78.283
Model No. H Q
SF4B-H□C (A-J05)20 0.787 22.2 0.874
SF4B-A□C (A-J05)40 1.575 42.2 1.661
SF4B-□CA-J05 SF4B-□C
Assembly dimensions
The figure depicts side mounting using the side mounting bracket MS-SF4BC-6 (optional) and the intermediate supporting bracket for side
mounting bracket MS-SF4BC-7 (optional).
<Connector of the pigtailed type (with muting function) SF4B-□CA-J05>
Emitter Receiver
Light curtain
The CAD data in the dimensions can be downloaded from our website.
DIMENSIONS (Unit: mm in)
ø15.6 ø0.614
(45 1.772)
N
(1.3 0.051)
H
Q
5
0.197
10 0.394
31.5 1.240
34.3 1.350
(12.9 0.508)
19.6 0.772
28.7
1.130
8.7 0.343
2.3 0.091
27.4 1.079
D
ML
ø5 ø0.197 Gray cable
(with black line)
B
P
5.4 0.213
5.4
0.213
(47.1 1.854)
ø5 ø0.197 Gray cable
(1.3 0.051)
H
Q
5 0.197
10 0.394
31.5 1.240
34.3 1.350
19.6 0.772
28.7
1.130
8.7 0.343
2.3 0.091
27.4 1.079
22.7 0.894 22.7 0.894
D
B
P
N
ML
5.4 0.213
MS-SF4BC-4
MS-SF4BC-3
(47.1 1.854)
Beam pitch
Protective
height
5.4 0.213
108
4.252
12.9
0.508
12.9
0.508
12.9
0.508
108
4.252
120
4.724
120
4.724
SF4B-C
30
ø5 ø0.197 Gray cable ø5 ø0.197
Gray cable
(with black line)
46.4
1.827
46.4
1.827
19.6
0.772
19.6
0.772
32.2
1.268
31.5 1.240 31.5 1.240
12.5 0.492
26 1.024
24.3
0.957
24.3
0.957
12.5 0.492
26 1.024
(47.1 1.854)(47.1 1.854)
10 0.394 10 0.394
46.4 1.827 46.4 1.827
66.4 2.614 66.4 2.614
5.4 0.213
(39 1.535) (39 1.535)
5.4 0.2135.4 0.213
5.4 0.213
10 0.394 10 0.394
2.3
0.091
2.3
0.091
68.7
2.705 68.7
2.705
(24 0.945)(24 0.945)
(27.4 1.079) (27.4 1.079)
R
QQ
H H
U U DR
T
S
MM
T
S
39
1.535 39
1.535
108
4.252
108
4.252
120
4.724
120
4.724
10.8
0.425
32.2
1.268
10.8
0.425
4.7
0.185
4.7
0.185
24
0.945
24
0.945
Beam pitch
Protective
height
MS-SF4BC-6
MS-SF4BC-7
Model No. DM R S T U
SF4B-H□C (A-J05)SF4B-A□C (A-J05)
SF4B-H12C (A-J05) 220 8.661
264.4
10.409
245.8
9.677
270.4
10.646
SF4B-H16C (A-J05)SF4B-A8C (A-J05) 300 11.811 280 11.024 344.4
13.559
325.8
12.827
350.4
13.795
SF4B-H20C (A-J05) 380 14.961
424.4
16.709
405.8
17.748
430.4
16.945
SF4B-H24C (A-J05)SF4B-A12C (A-J05) 460 18.110 440 17.323 504.4
19.858
485.8
19.126
510.4
20.094
SF4B-H28C (A-J05) 540 21.260
584.4
23.008
565.8
22.276
590.4
23.244
SF4B-H32C (A-J05)SF4B-A16C (A-J05) 620 24.409 600 23.622 664.4
26.157
645.8
25.425
670.4
26.394
SF4B-H36C (A-J05) 700 27.559
744.4
29.307
725.8
28.575
750.4
29.543
SF4B-H40C (A-J05)SF4B-A20C (A-J05) 780 30.709 760 29.921 824.4
32.457
805.8
31.724
382.9
15.075
830.4
32.693
SF4B-H48C (A-J05)SF4B-A24C (A-J05) 940 37.008 920 36.220 984.4
38.756
965.8
38.024
462.9
18.224
990.4
38.992
SF4B-H56C (A-J05)SF4B-A28C (A-J05) 1,100 43.307 1,080 42.520 1,144.4
45.055
1,125.8
44.323
542.9
21.374
1,150.4
45.291
SF4B-H64C (A-J05)SF4B-A32C (A-J05) 1,260 49.606 1,240 48.819 1,304.4
51.354
1,285.8
50.622
402.9
15.862
841.9
33.146
1,310.4
51.590
SF4B-H72C (A-J05)SF4B-A36C (A-J05) 1,420 55.906 1,400 55.118 1,464.4
57.654
1,445.8
56.921
455.9
17.949
948.9
37.358
1,470.4
57.890
SF4B-H80C (A-J05)SF4B-A40C (A-J05) 1,580 62.205 1,560 61.417 1,624.4
63.953
1,605.8
63.220
508.9
20.035
1,055.9
41.571
1,630.4
64.189
SF4B-H88C (A-J05)SF4B-A44C (A-J05) 1,740 68.504 1,720 67.716 1,784.4
70.252
1,765.8
69.520
561.9
22.122
1,162.9
45.783
1,790.4
70.488
SF4B-H96C (A-J05)SF4B-A48C (A-J05) 1,900 74.803 1,880 74.016 1,944.4
76.551
1,925.8
75.819
614.9
24.209
1,269.9
49.996
1,950.4
76.787
Model No. H Q
SF4B-H□C (A-J05)20 0.787 22.2 0.874
SF4B-A□C (A-J05)40 1.575 42.2 1.661
SF4B-□CA-J05 SF4B-□C
Assembly dimensions
The figure depicts space-saving mounting using the side mounting bracket MS-SF4BC-6 (optional) and the intermediate supporting bracket for
side mounting bracket MS-SF4BC-7 (optional).
<Connector of the pigtailed type (with muting function) SF4B-□CA-J05>
Emitter Receiver
Light curtain
12.9
0.508
12.9
0.508
ø5 ø0.197 Gray cable
ø15.6 ø0.614
ø5 ø0.197
Gray cable
(with black line)
RR
TT
SS
(1.3 0.051)(1.3 0.051)
DD
HH
MM
UU
QQ
5 0.197
5
0.197
10 0.394 10 0.394
31.5 1.240
31.5
1.240
34.3
1.350
34.3 1.350
(12.9 0.508)
19.6 0.772 19.6 0.772
28.7
1.130
28.7
1.130
8.7 0.343 8.7 0.343
22.7
0.894
22.7
0.894
2.3 0.091
2.3
0.091
27.4 1.079 27.4
1.079
(45 1.772)
MS-SF4BC-3
MS-SF4BC-4 Protective
height
Beam pitch
5.4 0.213
5.4 0.213
(47.1 1.854)
5.4 0.213
5.4
0.213
108
4.252
12.9
0.508
120
4.724
120
4.724
108
4.252
(47.1 1.854)
The CAD data in the dimensions can be downloaded from our website.
DIMENSIONS (Unit: mm in)
SF4B-C
31
MS-SF4BC-1
MS-SF4BC-2
MS-SF4BC-3
Standard mounting bracket (optional)
Rear utility mounting bracket (optional)
Side utility mounting bracket (optional)
2 0.079
t1.5 t 0.059
17 0.669
9.3
0.366
5
0.197
45 °
45 °
2 × M3 mounting hole
(for main body mounting)
2 × M3 mounting hole
(for main body mounting)
2 0.079
t 1.5 t 0.059
17 0.669
5.4 0.213
9.3
0.366
5
0.197
5.4
0.213
9.3
0.366
R7.2 R0.283
10.7 0.421
10 0.394
5.4 0.213
R7.2 R0.283
6.5
0.256
10.8
0.425
6.5
0.256
11.5
0.453
15.7
0.618
29.4
1.157
11.8
0.465
21.6 0.850
21.6 0.850
11.8
0.465
29.4
1.157
15.7
0.618
11.5
0.453
10.8
0.425
10 0.394
10.7 0.421
45°
45°
9.3
0.366
5.4
0.213
The CAD data in the dimensions can be downloaded from our website.
DIMENSIONS (Unit: mm in)
Material: Stainless steel (SUS)
Four brackets (two each R and L type) per set
Eight M3 (length: 5 mm 0.197 in) hexagon-socket head
bolts and four M5 flat washers are attached.
Material: Stainless steel (SUS)
Four brackets (two each R and L type) per set
Eight M3 (length: 6 mm 0.236 in) hexagon-socket head
bolts and four M5 flat washers are attached.
Material: Stainless steel (SUS)
Four brackets (two each R and L type) per set
Eight M3 (length: 6 mm 0.236 in) hexagon-socket head
bolts and four M5 flat washers are attached.
10
0.394
3 0.118
t 2 t 0.079
4
0.157
5.5
0.217
2 × M3 mounting hole
(for main body mounting)
8
0.315
10
0.394
10
0.394
28
1.102
15
0.591
3 0.118
t 2 t 0.079
(6 0.236)
17
0.669 11
0.433
8
0.315
10
0.394
4
0.157
5.5
0.217
2 × M3 mounting hole
(for main body mounting)
5.4
0.213
9.3
0.366
R7.2 R0.283
22.7
0.894
36.4
1.433
R7.2 R0.283
20.4
0.803
28
1.102
9.3
0.366
(6 0.236)
20.4
0.803
19.6
0.772
5.4
0.213
4
0.157
19.6
0.772
12
0.472
8
0.315
12
0.472
4
0.157
8
0.315
15
0.591
14
0.551
23.8
0.937
17
0.669
11
0.433
22.7
0.894
36.4
1.433
14
0.551
23.8
0.937
Note 1 Note 1
5.4 0.213
t 2 t 0.079
9.3
0.366
15 0.591
2 × M3 mounting hole
(for main body mounting)
5.4 0.213
9.3
0.366
2 × M3 mounting hole
(for main body mounting) R7.2
R0.283
t 2 t 0.079
R7.2
R0.283
28
1.102
32.5 1.280
13.7
0.539
19.4
0.764
28.7
1.130
8.7 0.343
10
0.394
22.7 0.894
32.5 1.280
28
1.102
19.4
0.764
13.7
0.539 28.7
1.130
10
0.394
8.7 0.343
15 0.591
22.7 0.894
Note 1 Note 1
Note 1: The adjustment range of the light
curtain angle is up to ±7 degrees.
Note 1: The adjustment range of the light
curtain angle is up to ±7 degrees.
SF4B-C
32
MS-SF4BC-4
MS-SF4BC-5
Intermediate supporting bracket for utility mounting bracket (optional)
Intermediate supporting bracket for standard mounting bracket (optional)
<For rear mounting>
<For rear mounting>
<For side mounting>
<For side mounting>
Material: Stainless steel (SUS)
Two pcs. M5 flat washers, two pcs. assembled M3 (length: 6 mm 0.236 in) hexagon-socket head bolts for rear mounting, two pcs. attachments for side mounting
Material: Stainless steel (SUS)
Two pcs. for rear mounting, two pcs. for side mounting
Note: The numbers of sets required by SF4B-H□C (A-J05) (40 or more beam axes) and SF4B-A□C (A-J05) (20 or more beam axes) are as follows:
SF4B-H40C (A-J05), SF4B-H48C (A-J05), SF4B-H56C (A-J05), SF4B-A20C (A-J05), SF4B-A24C (A-J05), SF4B-A28C (A-J05): 1set
SF4B-H64C (A-J05), SF4B-H72C (A-J05), SF4B-H80C (A-J05), SF4B-A32C (A-J05), SF4B-A36C (A-J05), SF4B-A40C (A-J05): 2 sets
Note: The numbers of sets required by SF4B-H□C (A-J05) (40 or more beam axes) and SF4B-A□C (A-J05) (20 or more beam axes) are as follows:
SF4B-H40C (A-J05), SF4B-H48C (A-J05), SF4B-H56C (A-J05), SF4B-A20C (A-J05), SF4B-A24C (A-J05), SF4B-A28C (A-J05): 1 set
SF4B-H64C (A-J05), SF4B-H72C (A-J05), SF4B-H80C (A-J05), SF4B-A32C (A-J05), SF4B-A36C (A-J05), SF4B-A40C (A-J05): 2 sets
t 1.5 t 0.059
t 2 t 0.079
0.5 0.020
26
1.024
4
0.157
(28.5 1.122)
t 1.5 t 0.059
t 2 t 0.079
3.6 0.142
26
1.024
1 0.039
32.2 1.268
20.6 0.811
15.5
0.610
(20.2 0.795)
7.2
0.283
6
0.236
20.6 0.811
30.6 1.205
5.4 0.213
11
0.433
13.5
0.531
18.5
0.728
38.5
1.516
9
0.354
5.2 0.205
38.7
1.524
11.2
0.441
34.7
1.366
20 0.787
30 1.181
5.4 0.213
33.5
1.319
18.5
0.72813.5
0.531
11
0.433
20.5 0.807
10.5
0.413
27.5 1.083
31.5 1.240
(20.2 0.795)
15
0.591
15.5
0.610
28.5
1.122
5.7
0.224
22.7
0.894
11.1
0.437
34.3
1.350
22.4 0.882
30.4 1.197
9.8
0.386
t 2 t 0.079
14.8
0.583
22.8 0.898
t 2 t 0.079
33
1.299
20
0.787
5 0.197
30
1.181
2 × M3 mounting hole for countersunk screw
6 × M3 mounting hole for countersunk screw
24.6
0.969
18.7 0.736
13.4
0.528
13.7
0.539
40
1.575
20
0.787
20
0.787
15
0.591
60
2.362
25
0.984
8.7
0.343
The CAD data in the dimensions can be downloaded from our website.
DIMENSIONS (Unit: mm in)
SF4B-C
33
MS-SF4BC-6 Side mounting bracket (optional)
MS-SF4BC-7 Intermediate supporting bracket for side mounting bracket (optional)
Mating cable with connector on one end (optional)
SFB-CC□-MU
ø6
ø0.236
L
ø15.6
ø0.614
45
1.772
ø6
ø0.236
L
ø15.6
ø0.614 ø15.6
ø0.614
45
1.772
45
1.772
SFB-CCJ□-MU
Mating cable with connectors on both ends (optional)
Model No. Length: L
SFB-CC3-MU 3,000 118.110
SFB-CC7-MU 7,000 275.591
SFB-CC10-MU
10,000 393.701
Length: L
Model No. Length: L
SFB-CCJ3D-MU 3,000 118.110
SFB-CCJ3E-MU
SFB-CCJ10D-MU
10,000 393.701
SFB-CCJ10E-MU
Length: L
The CAD data in the dimensions can be downloaded from our website.
DIMENSIONS (Unit: mm in)
3
t 2 t 0.079
R7.2
R0.283
R7.2
R0.283
10
0.394
10
0.394
10
0.394 10
0.394
t 2 t 0.079
24
0.945
20
0.787
20
0.787
45.4
1.787
45.4
1.787
5.4 0.213 5.4 0.213
4 0.157 4 0.157
46.4
1.827
46.4
1.827
25.4
1.000
25.4
1.000
19.4
0.764
19.4
0.764
13.7
0.539
13.7
0.539
20
0.787
20
0.787
12.5
0.492
12.5
0.492
15
0.591
15
0.591
66.4
2.614
66.4
2.614
9.7
0.382
9.3
0.366
9.7
0.382
9.3
0.366
9
0.354
M3 mounting hole
(for main body
mounting)
M3 mounting hole
(for main body
mounting) 9
0.354
24
0.945
22.3 0.878
(26 1.024)
22.3 0.878
(26 1.024)
32
1.260
32
1.260
4
0.157
4
0.157
Note 1 Note 1
Material: Stainless steel (SUS)
Four brackets (two each L and R type) per set
Eight M3 (length: 6 mm 0.236 in) hexagon-socket head
bolts and four M5 flat washers are attached.
Material: Stainless steel (SUS)
Two brackets per set
Two M5 flat washers and M3 (length: 6 mm 0.236 in) hexagon-
socket head bolts in assembled state are attached.
31.5 1.240
32.2
1.268
20.6
0.811
15.5
0.610
27.5 1.083
4 0.158
1.8 0.071
20 0.787
20.8
0.819
13.2
0.520
15
0.591
10
0.394 10
0.394
14.5
0.571
11.5
0.453
13.5
0.531
17.2 0.678
11 0.433
5.4 0.213
37.2 1.465
37.5
1.476
15.5
0.610
t 2
t 0.079
3.6 0.142
9 0.354
t 1.5 t 0.059
(28.5 1.122)
20.2
0.795
12.5
0.492
8.1
0.319
Note 1: The adjustment range of the light curtain angle is up to ±7 degrees.
SF4B-C
SF-C13 Control unit (optional)
13.5
0.531
10
0.394
4 0.157
6.5
0.256
80 3.150
80.8 3.181
Suitable for 35 mm 1.378 in width DIN rail
6 0.236
5 0.197
6.75
0.266
3 × 5 = 15
0.118 × 0.197 = 0.591
5 0.19713 0.512
22.5
0.886
130
5.118
67.3
2.650
35
1.378
34.5
1.358
91.6
3.606
Handy-controller (optional)
SFB-HC
25.4
1.000
23
0.906
65 2.559
30
1.181
ø6 ø0.236 cables,
0.5 m 1.640 ft long
140
5.512
Large display unit for light curtain (optional)
SF-IND-2
6.6 0.260
t 1.6 t 0.063
10.4 0.409
ø3.6 ø0.142 cable,
3 m 9.843 ft long
23
0.906
25
0.984
Material: Bracket ··· Cold rolled carbon steel
(SPCC)(Black chromate)
Enclosure ··· POM
Cover ··· Polycarbonate
5.5 0.217
18
0.709
28 1.102
4.6 0.181
35.5
1.398
40.1
1.579
18.3
0.720
22.8
0.898
25.4 1.000
The CAD data in the dimensions can be downloaded from our website.
DIMENSIONS (Unit: mm in)
Please contact ..........
2431-1 Ushiyama-cho, Kasugai-shi, Aichi, 486-0901, Japan
Global Sales Department
Telephone: +81-568-33-7861 Facsimile: +81-568-33-8591
panasonic.net/id/pidsx/global