Preliminary Information
CV211-1
PCS/DCS-band Dual-Branch Downconverter
Product Features
• High dynamic range downconverter
with integrated LO driver and IF
amplifiers
• Dual channels for diversity
• +27 dBm Input IP3
• +12 dBm Input P1dB
• 11.5 dB Noise Figure
• RF: 1710 - 1910 MHz
• IF: 70 - 250 MHz
• Low-side LO downconverter
• Single supply operation (+5 V)
• 6 x 6 mm QFN SMT package
Product Description
The CV211-1 is a dual-channel high-linearit
downconverter designed to meet the
erformance, functionality, and cost goals o
current and next generation mobile infrastructure
basestations.
It is ideally suited for high dynamic range
receiver front ends using diversity receive
channels. The module is implemented in reliable
GaAs MESFET technology and requires only a
small 6x6 mm footprint.
Typical applications include frequenc
downconversion used in CDMA/GSM/TDMA,
CDMA2000, W-CDMA, and EDGE 2.5G and
3G mobile base transceiver stations.
Functional Diagram
Top View
Specifications1
Parameters Units Minimum Typical Maximum Comments
RF Frequency Range MHz 1710 1910
LO Frequency Range MHz 1460 1840
IF Frequency Range MHz 70 250
IF Bandwidth % 20
SSB Conversion Gain dB 8 10 12
Input IP3 dBm +27 ∆f = 1 MHz @ RFin = 0 dBm / tone
Input IP2 dBm +32
Input 1 dB Compression Point dBm +12
Noise Figure dB 11.5 12.5
LO Input Drive Level dBm -2.5 0 +2.5
LO-RF Isolation dB 9 P
LO = 0 dBm
LO-IF Isolation dB 30 P
LO = 0 dBm
Branch-Branch Isolation dB 35
Return Loss: RF Port dB 14
Return Loss: LO Port dB 14
Return Loss: IF Port dB 14
Operating Supply Voltage V +4.75 +5 +5.25
Supply Current mA 380 460
1 Specifications when using application specific circuit with a low side LO = 0 dBm in a downconverting application at 25°C.
Absolute Maximum Rating2 Ordering Information
Parameters Rating Part No. Description
Operating Case Temperature -40° to +85 °C CV211-1 PCS/DCS-band Dual-Branch Downconverter
Storage Temperature -65° to +100 °C
Maximum Junction Temperature +150 °C
2 Operation of this device above any of these parameters may cause permanent damage.
CV Actual Size
8
23
1
17
IF amp
25
27
LO driver amp
IF
RF
7
9 11 13
IF
IF amp
RF
+Vcc 21