Product Brochure
Eaton ePDU G3
Managed
Good Better Best
2EATON Eaton ePDU G3
Advanced power management and
precision control
The Eaton® ePDU® third generation (G3) Managed models build on Eatons existing state-of-the-art ePDU G3 technology while
offering new capabilities for rack power distribution in data centers and information technology (IT) applications. You now have
comprehensive management and monitoring capabilities down to the outlet level. This new level of precision saves time,
saves money and avoids risk, making the ePDU G3 Managed the gold standard in power management.
Key applications
ePDU G3 Managed models
are available in a variety of
plug and outlet configurations,
including both 120 and 200-
240 volt configurations. The
ePDU G3 Managed models
give you advanced control
of the rack environment,
making it a perfect fit for a
variety of applications.
Remote office/branch office
• Portfolio of 120V and lower power ratings (kVA)
• Reboot devices without local IT staff assistance
• Control unused outlets to prevent unauthorized use
• LCD pixel menu display simplifies setup
Enterprise data center
• Up to 208V three phase 17kW for high density applications
• Network monitoring of power usage and capacity at the
outlet level
• Save time by rebooting devices from the operations center
• Measure power for Level 3 PUE
ePDU G3 key technology features Basic (BA) Metered Input (MI) Managed (MA)
IEC outlet grip plug retention
Low-profile form factor
High 140°F (60°C) operating temperature
Color-coded outlet sections
Ease of installation
One percent billing grade accuracy
Advanced LCD pixel display
Daisy chain (share network connection/IP address)
Hot-swap meter
Phase and section metering
Outlet switching
Turn off unused outlets
Remote site management
Measure power consumption at outlet level
Measure Level 3 power usage effectiveness (PUE)
Group reboot for A and B feed
Increasing level of control
3
EATON Eaton ePDU G3
Color-coded outlet sections
Color-coded outlet sections match a corresponding circuit
breaker to easily identify which one feeds corresponding
outlets and prevent unbalanced loading that would
unnecessarily trip a breaker.
Grouped reboot for A and B feed
When connecting multiple source input servers to an A and
B feed power source, the daisy-chain capability allows you
to group power supplies across the ePDU. As a result, all
the power supplies are controlled with a single action, which
saves time rebooting servers with two to six power supplies.
Outlet switching
Remotely control devices by powering on or off individual
outlets. Save time and operating costs by rebooting machines
from your control center without costly site visits.
Turn off unused outlets
Secure and protect your environment by easily turning off
unused outlets. Avoid overloading your system from others
plugging in unauthorized devices. Also consider closing
access with an outlet cap.
Outlet grip functionality
Eatons patent-pending IEC outlet grip secures plugs in
place with a lever-actuated grip that’s integrated into each
outlet. Once the levers click into the grip position, the plugs
are secured from accidental disconnect due to bumps or
vibrations without the need for special power cords.
O is unlocked, + is grip engaged
Typical server with multiple power inputs powered by two ePDUs
Green LED signifies power on and
red is power off to outlet
Cap secures in place with cable tie
4
EATON Eaton ePDU G3
One percent billing grade accuracy
ePDU G3 provides one percent revenue-grade power
monitoring for higher accuracy in department billing
or colocation data centers. Effectively measure
power usage to all outlets or individual outlets.
Advanced LCD pixel display with
hot-swap capability
Eatons new hot-swap eNMC (ePDU Network Management and
Control) module can be replaced without the need to power
down your rack. Increase uptime while enhancing serviceability
and saving on unnecessary service calls. The menu-driven pixel
display allows for easy setup and troubleshooting.
Daisy chain four units from one IP address
Eatons new patented daisy-chain capability allows up to four
ePDUs to share the same network connection and IP address.
Unlike competitive rack PDUs that require a dedicated IP
address for best performance, Eaton technology provides a
75-percent reduction in network infrastructure costs.
A and B power PDU sharing a network connection via daisy chain
Module being removed without removing power to the ePDU
5
EATON Eaton ePDU G3
eaton.com/ePDUG3
Remote site management
Manage ePDU G3s using a web browser or via SNMP
integration into monitoring or DCIM software. Simplify
management by using the daisy-chain capability to manage up
to four ePDU G3s with a single IP address. Avoid costly site
visits by remotely rebooting and monitoring the site, allowing
more time to manage other critical tasks
Measure power consumption at the outlet level
Acquire more accurate and detailed data by measuring power at the outlet level. Gain energy analysis at a deeper level to make
informed decisions and assist with effectively deploying equipment. Compare efficiency between manufacturers and understand
what drives power usage so you can make intelligent decisions to reduce power consumption.
Measure Level 3 PUE
PUE is an industry-wide accepted method to measure power effectiveness. Measuring at the
outlet level removes upstream devices from the calculation to provide an accurate view of how
effectively power is being used for the connected IT equipment. Data center managers typically
prefer Level 3 PUE for the most accurate PUE calculation.
Perform department and customer billing
Metering at the outlet level provides customer-level energy
tracking and turns power billing into a revenue stream that
considers actual usage. Similarly, you can measure power
usage per application and assign it to specific departments
for budgeting purposes or to justify costs.
PUE measurement Level 1: Basic Level 2: Intermediate Level 3: Advanced
IT equipment energy UPS outputs PDU outputs IT equipment input
Total facility energy Utility inputs Utility inputs Utility inputs
Measurement intervals Monthly/weekly Daily/hourly Continuous (15 minutes or less)
Increase effectiveness and reduce operating costs
Make selection
,
advance to next screen
Make selection
,
advance to next screen
To obtain Level 3 PUE, you must take measurements at the IT equipment level in intervals of at least 15 minutes.
Each outlet can be billed separately.
From meter screen, select outlets... From outlet screen, select
specific outlet to view...
View live power levels for
selected outlet
Part Number Description
EMP001 Environmental monitoring probe
010-0029 2-foot C13 to C14 jumper cord
010-0028 4-foot C13 to C14 jumper cord
010-0027 6-foot C13 to C14 jumper cord
010-0025 8-foot C13 to C14 jumper cord
035-0113 C13 outlet cap
035-0119 C19 outlet cap
Eaton and ePDU are registered
trademarks of Eaton.
All other trademarks are property
of their respective owners.
Eaton
Electrical Sector
1000 Eaton Boulevard
Cleveland, OH 44122 USA
Eaton.com
© 2015 Eaton
All Rights Reserved
Printed in USA
BR155006EN
October 2014
For more information
on the new G3
platform, visit
Eaton.com/ePDUG3
Catalog number Input plug Cord (ft) Breaker Current (A) Max kW Output receptacles Dimensions (H x W x D, in)
EMA112-10 5-15P 10 None 12 1.44 (16) 5-20R 66.5 X 2.05 X 2.56
EMA114-10 L5-20P (5-20P adapter) 10 None 16 1.92 (24) 5-20R 66.5 X 2.05 X 2.09
EMA108-10 L5-30P 10 (2) 20A 24 2.88 (24) 5-20R 66.5 x 2.05 x 2.56
EMA106-10 C20 (L6-20 adapter) 10 None 16 3.84 (7) C13, (1) C19 35.5 x 2.05 x 2.1
EMA107-10 L6-30P 10 (2) 20A 24 5.76 (20) C13, (4) C19 66.5 x 2.05 x 2.1
EMA324-10 L15-20P 10 (3) 20A 24 5.76 (18) C13, (6) C19 66.5 x 2.05 x 2.56
EMA325-10 L21-20P 10 (3) 20A 24 5.76 (18) C13, (6) C19 66.5 x 2.05 x 2.56
EMA339-10 L15-20P 10 (3) 20A 16 5.76 (21) C13, (3) C19 66.5 x 2.05 x 2.09
EMA340-10 L21-20P 10 (3) 20A 16 5.76 (21) C13, (3) C19 66.5 x 2.05 x 2.09
EMA326-10 L15-30P 10 (3) 20A 24 8.64 (18) C13, (6) C19 66.5 x 2.05 x 2.56
EMA327-10 L21-30P 10 (3) 20A 24 8.64 (18) C13, (6) C19 66.5 x 2.05 x 2.56
EMA333-10 L21-30P 10 (3) 20A 24 8.64 (21) C13, (6) C19, (1) 5-20R 66.5 X 2.05 X 2.56
EMA341-10 L15-30P 10 (3) 20A 24 8.64 (21) C13, (3) C19 66.5 x 2.05 x 2.09
EMA342-10 L21-30P 10 (3) 20A 24 8.64 (21) C13, (3) C19 66.5 x 2.05 x 2.09
EMA328-10 CS8365 10 (3) 20A 35 12.48 (18) C13, (6) C19 66.5 x 2.05 x 2.56
EMA343-10 CS8365 10 (3) 20A 35 12.48 (21) C13, (3) C19 66.5 x 2.05 x 2.09
EMA329-06 CS8365 6 (6) 20A 40 14.4 (12) C13, (12) C19 66.5 x 2.05 x 2.56
EMA330-06 IEC60309 460P9W 6 (6) 20A 48 17.3 (12) C13, (12) C19 66.5 x 2.05 x 2.56
ePDU G3 Managed selection guide
ePDU G3 accessories
Ease of installation
• Patented clip feet allow for
multiple mounting methods
• Mounting buttons come
pre-installed to reduce
installation time
• Double-sided buttons
accommodate different
variations of metal thickness
• Optional side mounting
button locations to mount
ePDU G3s at a 90-degree
rotation in the rack,
preventing interference
with hot-swap fans and
power supplies
Eaton patented clip feet Mounting buttons come pre-installed
Environmental monitoring
The optional environmental monitoring probe connects to the serial
port and enables you to collect temperature and humidity readings
in the rack environment to monitor
environmental data remotely. You can
also monitor the status of two contact
closure devices, such as door switches.
Part Number EMP001