DC/DC CONVERTERS 3W Wide Input DC/DC Converters 1
2 YEAR WARRANTY
BXA3 Series
Single and dual output
•3 Watts in DIL Package
•9 models including 3.3VDC output
•Wide input ranges 9-18V, 18-36V, 36-75V
•EN55022 conducted emissions level A (optional)
•Continuous short circuit protection
•Operating temperature range -25°C to +105°C
•Input voltage range to ETS300-132-2
•UL, VDE and CSA safety approvals
The BXA3 Series of DC/DC converters is designed to offer the optimum
cost/benefit power solution for a wide variety of applications including public
and private telecommunications, industrial systems and process and test
equipment. The series consists of 9 models with input voltages of 9-18VDC, 18-
36VDC and 36-75VDC, and offers standard output voltages of 3.3V, 5V, 12V and
15V in single and dual output configurations. Continuous short circuit protection,
overvoltage protection, 60mV output ripple and EN55022 level A conducted
noise compliance minimize design-in time, cost and eliminate the need for
external components.
All specifications are typical at nominal input, full load at 25°C unless otherwise stated
EMC CHARACTERISTICS
Conducted emissions EN55022, FCC part 15 Level A
Suffix ‘-F’ versions
(See Notes 5 and 6)
GENERAL SPECIFICATIONS
Efficiency See table
Isolation voltage Input/output 500VDC
Switching frequency Variable 200kHz to1MHz
Approvals and VDE0805, EN60950, IEC950
standards UL1950, CSA C22.2 No. 950
Case material Non-conductive
black plastic
Material flammability UL94V-0 min.
Weight 15g (0.53oz)
MTBF MIL-HDBK-217F 800,000 hours
ENVIRONMENTAL SPECIFICATIONS
Thermal performance Operating ambient -25°C to +105°C
(See derating curve)
Non-operating amb -40°C to +105°C
Cooling Free air convection
cooled
Relative humidity Non-condensing 5% to 95% RH
Altitude Operating 10,000 feet max.
Non operating 40,000 feet max.
Vibration 5Hz to 500Hz 2.5G rms (approx.)
OUTPUT SPECIFICATIONS
Voltage accuracy ±1.0%
Line regulation LL to HL, all outputs ±2.5%
Load regulation Full load to no load ±2.5%
Ripple and noise +5V output 60mV pk-pk, max.,
(5Hz to 20MHz) 15mV rms
All others 100mV pk-pk, max.,
15mV rms
Temperature coefficient ±0.02%/°C, max.
Over voltage protection Clamp diode 135% Vout
Short circuit protection Continuous
automatic recovery
INPUT SPECIFICATIONS
Input voltage range 12VDC 9 to 18VDC
24VDC 18 to 36VDC
48VDC 36 to 75VDC
Input filter Suffix ‘-F’ (See Note 5) Pi type
Reverse voltage (See Note 7) Yes
protection
Max. input rise Output remains within 5V/ms
and fall time specification
File Name: bxa3.pdf Rev: 10 August 2005
SPECIFICATIONS
International Safety Standard Approvals
VDE0805/EN60950/IEC950 Licence No. 5856
UL1950 File No. E136005
CSA C22.2 No. 950 File No. LR41062C