Characteristics Item Specifications
Contact Arrangement 1 Form C, 1 Form A
Contact resistance (Initial) Max. 100 m(By voltage drop 6V DC 1A)
Contact material AgSnO2 type
Rating
Nominal switching capacity (resistive load) 16A 250V AC
Max. switching power (resistive load) 4,000V A
Max. switching voltage 440V AC
Max. switching current 16A
Nominal operating power 400mW
Min. switching capacity*1
*1 This value can change due to the switching frequency , environmental conditions, and desired reliability level, therefore it is recommended to check this with the actual load.
100mA 5V DC
Electrical
characteristics
Insulation resistance (Initial) Min. 1,000M (at 500V DC)
Breakdown voltage
(Initial)
Between open contacts 1,000 Vrms for 1min. (Detection current: 10mA)
Between contact and
coil 5,000 Vrms for 1min. (Detection current: 10mA)
Temperature rise (at 20C 68F)Max. 55C 131F
[with nominal coil voltage and at 16A contact carrying current (resistance method) at 20°C 68F]
Surge breakdown voltage*2
(Between contacts and coil)
*2 Wave is standard shock voltage of 1.2 50s according to JEC-212-1981
10,000 V (Initial)
Operate time (at nominal voltage) (at 20C 68F) Max. 15ms (excluding contact bounce time)
Release time (at nominal voltage) (at 20C 68F) Max. 5ms (excluding contact bounce time, without diode)
Mechanical
characteristics
Shock resistance Functional Min. 100 m/s2 {10G} (Half-wave pulse of sine wave: 11ms; detection time: 10s.)
Destructive Min. 1,000 m/s2 {100G} (Half-wave pulse of sine wave: 6ms.)
Vibration resistance Functional 10 to 55 Hz at double amplitude of 1.5mm (Detection time: 10s.)
(Only the N.C. side of 1 Form C is 0.8mm)
Destructive 10 to 55 Hz at double amplitude of 1.5mm
Expected life Mechanical (at 180 times/min.) Min. 107
Electrical (at 20 times/min.)*3
*3 In order to obtain the full rated life cycles, the relay should be properly vented by removing the vent nib. For details, please refer to NOTES.
N.O.: Min. 105, N.C.: Min. 5104
Conditions
Conditions for operation, transport and storage
*4
,
*5
*4 Class F type is ambient temperature 105°C +221F.
*5 The upper limit of the ambient temperature is the maximum temperature that can satisfy the coil temperature rise value. Refer to “6. Usage, Storage and Transport
Conditions” in AMBIENT ENVIRONMENT (page 626).
* Please note that some of the specifications listed above may not comply with overseas standards.
Ambient temperature: –40C to +85C –40F to +185F (Class B)
Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature)
Max. operating speed 20 times/min. (at nominal switching capacity)
Unit weight Approx. 12 g .42 oz
1. Max. switching power (AC resistive load) 2. Max. switching power (DC resistive load) 3. Coil temperature rise
Sample: ALZ1 1F12, 5pcs.
Measured portion: coil inside
Contact current: 0 A, 16 A
101 30 1000
1
10
16
100
100 440
Contact voltage, V
Contact current, A
100
1
10
100
100
Contact current, A
Contact voltage, V
1000 120 125110 115105 130 135
30
25
35
40
50
45
55
20
Normal
temperature
Normal
temperature
16A
0A
85°C
105°C
85°C
105°C
Temperature rise, °C
Coil applied voltage, %V