Terminal Blocks, Fuse Blocks
and Fuse Holders
Screw Connection
Spring Cage
Insulation Displacement Connection
8.1 IEC—XB Series
IEC—XB Series Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V7-T8-2
Screw Connection Terminal Blocks . . . . . . . . . . . . . . . . . . . . . . . . . . . V7-T8-4
Spring Cage Terminal Blocks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V7-T8-31
Pluggable Spring Cage Connection Terminal Blocks. . . . . . . . . . . . . . . V7-T8-58
IDC Terminal Blocks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V7-T8-67
Miniature Circuit Breakers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V7-T8-82
XB Series Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V7-T8-90
8.2 NEMA
NEMA Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V7-T8-106
C381 Series Terminal Blocks, Rail Mounted . . . . . . . . . . . . . . . . . . . . V7-T8-107
TB Series Terminal Blocks, Modular . . . . . . . . . . . . . . . . . . . . . . . . . . . V7- T8 -111
8.3 Power Distribution
Power Distribution Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V7-T8-116
CHDB Series—Power Distribution Blocks . . . . . . . . . . . . . . . . . . . . . . V7-T8-117
CH160 Series—Power Terminal Blocks . . . . . . . . . . . . . . . . . . . . . . . . V7-T8-123
Power Terminal Block Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . V7-T8-126
8.4 Fuse Blocks and Fuse Holders
Fuse Blocks and Fuse Holders Overview . . . . . . . . . . . . . . . . . . . . . . . V7-T8-128
C383 Series Disconnect Fuse Holders . . . . . . . . . . . . . . . . . . . . . . . . . V7-T8-129
C350 Series Fuse Blocks and W Series Fuse Holders . . . . . . . . . . . . . V7-T8-131
Learn
Online
V7-T8-2 Volume 7—Logic Control, Operator Interface and Connectivity Solutions CA08100008E—November 2011 www.eaton.com
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8.1
Terminal Blocks, Fuse Blocks and Fuse Holders
IECXB Series
IEC—XB Series
Contents
Description Page
IEC—XB Series
Screw Connection Terminal Blocks . . . . . . . . . V7-T8-4
Spring Cage Terminal Blocks . . . . . . . . . . . . . . V7-T8-31
Pluggable Spring Cage Connection
Terminal Blocks. . . . . . . . . . . . . . . . . . . . . . . . V7-T8-58
IDC Terminal Blocks . . . . . . . . . . . . . . . . . . . . . V7-T8-67
Miniature Circuit Breakers. . . . . . . . . . . . . . . . . V7-T8-82
XB Series Accessories . . . . . . . . . . . . . . . . . . . V7-T8-90
IEC—XB Series Overview
Product Description
The XB Series from Eaton
offers a complete terminal
block system with a universal
range of accessories.
Marking, bridging and testing
accessories are standardized
across the different
termination technologies—
reducing inventory and
logistics costs. The modular
terminal block design allows
for use of the different
terminal block types together
or individually, providing the
highest degree of flexibility.
Application Description
The metal portion of the XB
Series terminal blocks are
made from high-grade, strain-
crack and corrosion-proof
copper alloys. They won’t
experience any electrolytic
corrosion or rusting, even
when moisture is present.
The metal surfaces are
protected with a lead-free,
galvanic nickel or tin plating.
The good electrical
conductivity permits only a
low temperature rise. The
Polyamide 6.6 housings
allow for operating
temperatures up to 257°F
(125°C) and are certified for
inflammability Class V0 in
accordance with UL 94.
Features
Global acceptance—The XB
Series terminal blocks are
designed to worldwide
standards and meet the latest
international requirements.
Flexible Plug-in bridge
system—All three
technologies (screw, spring
and IDC) use the same bridge
system, allowing for
individual potential
distribution and quickly
bridged connections among
the same terminal block type
or across different types. The
XB Series terminal blocks
have two bridge shafts
arranged in one line, making
flexible chain bridging and
skip bridging between non-
adjacent terminal blocks
possible. Plug-in bridges are
available from 2 to 50
positions. Reducing bridges
are also available to connect a
larger terminal block to a
smaller one.
Large surface area for
marking—All XB Series
terminal blocks have
generously sized surface
areas for labeling. This allows
for clearly labeled wiring that
results in reduced startup
time and simplifies activities
such as testing and
maintenance. There are
provisions for marking
individual terminal blocks and
end stops, strips of terminal
blocks, and large groups of
terminal blocks.
Standardized testing
system—All test plugs make
contact in one of the easily
accessible bridge shafts. A
2.3 mm diameter test plug is
available for individual
measuring wires. Modular
test plugs are also available
for more advanced testing.
Standards and Certifications
UL® and cUL®
recognized—File No.
E67464
CE approved
LVD 1
EN 60947-7-1
EN 60947-7-2
EN 60998-2-3
EN 60352-4/A1
ATEX approval
(Eex e applications)
Note
1Not all standards apply to all terminal
blocks. Contact Eaton for details.
Volume 7—Logic Control, Operator Interface and Connectivity Solutions CA08100008E—November 2011 www.eaton.com V7-T8-3
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8.1
Terminal Blocks, Fuse Blocks and Fuse Holders
IEC—XB Series
Technical Data and Specifications
IEC—XB Series
Modular Terminal Blocks for Potentially Explosive Environments
The standard modular
terminal blocks from Eaton
are approved for potentially
explosive environments. In
addition to the usual
approvals, they also have
been approved by a testing
center authorized by the EU.
No extra approval is required
in Intrinsic Safety type
applications.
Modular terminal blocks on
www.eaton.com fulfill the
requirements for “Increased
Safety” protection type when
installation instructions are
followed, and have a type
examination certificate
in accordance with the
Ex directive Ex-RL 94/9/EU.
These test certificates are
recognized in all the EU
member states and beyond.
The modular terminal blocks
are approved for fitting in
Zone 1, the Ex environment,
as well as Zone 2. Zone 1
fitting is conditional upon
terminal blocks being used in
connection boxes approved
for EEx e type protection and
having the equivalent of at
least IP54 protection.
The EEx approved modular
terminal blocks can be
divided into the following
groups:
Screw connection
terminal blocks
Spring-cage connection
terminal blocks
Insulation Displacement
Connection terminal blocks
Mini terminal blocks
Terminal blocks for
specialized applications
More detailed information
on modular terminal
blocks in the EEx e area is
available on the Internet
at www.eaton.com for
downloading.
Here you will find the
following:
Technical data in accordance
with EN 50 019
Approved accessories
Important installation
instructions and mounting
diagrams
EU type examination
certificates
General information on
Ex protection
Identifications
Explosion protected electrical
equipment must be marked
so that the safety
characteristics are
identifiable. The identification
of electrical equipment is
described in the harmonized
standard EN 50014, as shown
in the following example:
EN 50014
Standard Example
Identification in Accordance
with ATEX-RL
Electrical equipment that is
certified in accordance with
the ATEX 100a guideline also
receives identification
describing the site for use.
ATE X
Guideline Example
Description Specification
Insulation material Polyamide 6.6
Dielectric strength 600 kV/cm
Creep resistance 600 CTI
Internal insulation resistance 1012 ohms cm
Surface resistance 1010 ohms
Flammability rating UL 94 V0
Continuous operating temperature –40 to 257°F (–40 to 12C)
Description Identification
Manufacturer or
trademark
Eaton
Type designation XBUT25
Abbreviation of
explosion protection
EEx e ll
Protection type
increased safety “e”
e
Equipment group II
Mark of the
testing body
KEMA
Approval number 05ATEX2158 U
Description Identification
Manufacturing data 02.01.2004
Address of the
manufacturer
Duncan, SC
Number of the
appointed dept.
344
Common marking Ex symbol
Equipment group II
Category 2
Use in gas and/or
dust atmospheres
G D
V7-T8-4 Volume 7—Logic Control, Operator Interface and Connectivity Solutions CA08100008E—November 2011 www.eaton.com
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8.1
Terminal Blocks, Fuse Blocks and Fuse Holders
IECXB Series
Screw Connection
Contents
Description Page
Screw Connection Terminal Blocks
Single Level—Through-Feed . . . . . . . . . . . . . . . V7-T8-5
Single Level—Ground Blocks . . . . . . . . . . . . . . V7-T8-10
Multi-Conductor Terminal Blocks . . . . . . . . . . . V7-T8-12
Multi-Conductor Ground Blocks . . . . . . . . . . . . V7-T8-14
Double Level . . . . . . . . . . . . . . . . . . . . . . . . . . . V7-T8-16
Triple Level Sensor/Actuator . . . . . . . . . . . . . . . V7-T8-18
Fuse Terminal Blocks . . . . . . . . . . . . . . . . . . . . V7-T8-21
Disconnect and Component Terminal
Blocks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V7-T8-24
High Current Blocks . . . . . . . . . . . . . . . . . . . . . V7-T8-27
Mini Screw Connection . . . . . . . . . . . . . . . . . . V7-T8-29
Drawings
Online
Screw Connection Terminal Blocks Overview
Product Description
The XBUT Series uses a
screw connection system
that is accepted worldwide
and is suitable in most
applications. The
maintenance-free connection
provides the reliability you
expect from Eaton.
Application Description
Designed for applications with
high demands, the XBUT
Series screw terminal block
has a maintenance-free wire
connection. re-tightening of
the terminal screws is not
necessary to ensure proper
operation. The screw locking
technique prevents the
screws from backing out.
Copper wires can be clamped
without pre-treatment or
ferrules can be used for
splicing protection. Multiple
conductors can be connected
in the same clamping
mechanism, saving space.
Features
Maintenance-free
connections
Global acceptance
Multi-conductor
connections
Flexible Plug-in bridge
system
Large surface area for
marking
Standardized testing
system
Metal parts made of tin-
plated copper alloy
Standards and Certifications
UL and cUL recognized—
File No. E67464
CE approved
LVD 1:
EN 60947-7-1
EN 60947-7-2
EN 60998-2-3
EN 60352-4/A1
ATEX approval
(Eex e applications)
Note
1Not all standards apply to all terminal
blocks. Contact Eaton for details.
Volume 7—Logic Control, Operator Interface and Connectivity Solutions CA08100008E—November 2011 www.eaton.com V7-T8-5
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8.1
Terminal Blocks, Fuse Blocks and Fuse Holders
IEC—XB Series
Single Level—Through-Feed
Contents
Description Page
Single Level—Through-Feed
Product Selection . . . . . . . . . . . . . . . . . . . . . . . V7-T8-6
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . V7-T8-7
Technical Data and Specifications . . . . . . . . . . V7-T8-9
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . V7-T8-9
Single Level—Ground Blocks . . . . . . . . . . . . . . . . V7-T8-10
Multi-Conductor Terminal Blocks . . . . . . . . . . . . . . V7-T8-12
Multi-Conductor Ground Blocks . . . . . . . . . . . . . . V7-T8-14
Double Level. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V7-T8-16
Triple Level Sensor/Actuator . . . . . . . . . . . . . . . . . V7-T8-18
Fuse Terminal Blocks . . . . . . . . . . . . . . . . . . . . . . . V7-T8-21
Disconnect and Component Terminal Blocks . . . . V7-T8-24
High Current Blocks . . . . . . . . . . . . . . . . . . . . . . . . V7-T8-27
Mini Screw Connection . . . . . . . . . . . . . . . . . . . . . V7-T8-29
Single Level—Through-Feed
Product Description
The XBUT terminal blocks
feature a compact design and
maintenance-free screw
connection. There is a double
bridge shaft providing
maximum flexibility.
The double bridge shaft can
accommodate individual
chain bridging and step-down
bridging from other terminal
blocks. There are numerous
options for accessories,
including those for testing
and marking. Terminal blocks
are available for wire cross-
sections ranging from
12 AWG (2.5 mm2) to
2/0 AWG (150 mm2).
V7-T8-6 Volume 7—Logic Control, Operator Interface and Connectivity Solutions CA08100008E—November 2011 www.eaton.com
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8.1
Terminal Blocks, Fuse Blocks and Fuse Holders
IECXB Series
Product Selection
Screw Connection Single Level—Through-Feed
Note
1 EU type—examination certificate number: KEMA 05ATEX2158 U.
Terminal
Width
Maximum
Wire Size
IEC 60 947-7-1
in V/A/AWG
EN 50 019 1
in V/A/AWG
UL-cUL Ratings
in V/A/AWG Color
Standard
Pack
Catalog
Number
5.2 mm 12 AWG/2.5 mm2800/32/26–12 750/22/28/26–12 600/20/26–12 Gray 50 XBUT25
Blue 50 XBUT25BU
6.2 mm 10 AWG/4 mm2800/41/26–10 750/30/38/26–10 600/30/26–10 Gray 50 XBUT4
Blue 50 XBUT4BU
Orange 50 XBUT4OR
Yellow 50 XBUT4YE
Red 50 XBUT4RD
White 50 XBUT4WH
Black 50 XBUT4BK
Green 50 XBUT4GN
8.2 mm 8 AWG/6 mm2800/57/24–8 750/40/50/24–8 600/50/24–8 Gray 50 XBUT6
Blue 50 XBUT6BU
10.2 mm 6 AWG/10 mm21000/76/20–6 750/54/69/20–6 600/65/20–6 Gray 50 XBUT10
Blue 50 XBUT10BU
Orange 50 XBUT10OR
Yellow 50 XBUT10YE
Red 50 XBUT10RD
12 mm 4 AWG/16 mm21000/101/17–4 600/85/16–4 Gray 50 XBUT16
Blue 50 XBUT16BU
16 mm 0 AWG/35 mm21000/150/15–0 600/150/14–1/0 Gray 50 XBUT35
Blue 50 XBUT35BU
XBUT4
Volume 7—Logic Control, Operator Interface and Connectivity Solutions CA08100008E—November 2011 www.eaton.com V7-T8-7
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8.1
Terminal Blocks, Fuse Blocks and Fuse Holders
IEC—XB Series
Accessories
Screw Connection Single Level—Through-Feed
Notes
1For ordering information, see Page V7-T8-105.
2For information on Printed Marking Tag Options, see Page V7-T8-98.
For additional accessories, see Page V7-T8-90.
Description Color
Number of
Positions
Standard
Pack
XBUT25 XBUT4 XBUT6 XBUT10 XBUT16 XBUT35
Catalog
Number
Catalog
Number
Catalog
Number
Catalog
Number
Catalog
Number
Catalog
Number
End cover Gray 10 XBACUT10 XBACUT10 XBACUT10 XBACUT10 XBACUT16 1
Partition plate Gray 10 XBATUT10 XBATUT10 XBATUT10 XBATUT10
Plug-in bridge—
for cross connections
in the bridge shaft
Red 2 10 XBAFBS25 XBAFBS26 XBAFBS28 XBAFBS210 XBAFBS212 XBAFBS216
310XBAFBS35 XBAFBS36
510XBAFBS55 XBAFBS56
10 10 XBAFBS105 XBAFBS106
50 10 XBAFBS505 XBAFBS506
Test adapter 10 XBATSPAI4 XBATSPAI4 XBATSPAI4
2.3 mm diameter test plug XBATSMPS-_ 1XBATSMPS-_ 1———
Modular test plug 10 XBATSPS5 XBATSPS6 XBATSPS8
Blank marker strip (strip of 10) White 10 XBMZB5 2XBMZB6 2XBMZB8 2XBMZB10 2XBMZB12 2XBMZB15 2
V7-T8-8 Volume 7—Logic Control, Operator Interface and Connectivity Solutions CA08100008E—November 2011 www.eaton.com
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8.1
Terminal Blocks, Fuse Blocks and Fuse Holders
IECXB Series
XBUT with Reducing Bridge
Step-Down Bridge with Standard Feed-Through Terminal Blocks
Input Pick-Off
One-Sided
Input Imax
Central
Input Imax
Bridge
Terminal
Blocks Cross-Section
Terminal
Blocks
Cross-Section
AWG (mm2)
Catalog
Number
XBUT10 6 AWG (10 mm2) XBUT25 12 (2.5) 40 65 XBARBUT10
XBUT4 10 (4) 45 65 XBARBUT10
XBPT25 12 (2.5) 40 65 XBARBUT10ST
XBPT4 10 (4) 45 65 XBARBUT10ST
XBQT15 14 (1.5) 35 65 XBARBUT10ST
XBQT25 12 (2.5) 40 65 XBARBUT10ST
XBUT16 4 AWG (16 mm2) XBUT25 12 (2.5) 40 80 XBARBUT16
XBUT4 10 (4) 45 90 XBARBUT16
XBPT25 12 (2.5) 40 80 XBARBUT16ST
XBPT4 10 (4) 45 90 XBARBUT16ST
XBQT15 14 (1.5) 35 70 XBARBUT16ST
XBQT25 12 (2.5) 40 80 XBARBUT16ST
XBPU25D12
lmax
One-Sided Input Central Input
lmax
XBACUT10
XBARBUT10ST
XBARBUT10
XBUT10 XBUT25
XBACPU25D12
Volume 7—Logic Control, Operator Interface and Connectivity Solutions CA08100008E—November 2011 www.eaton.com V7-T8-9
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8.1
Terminal Blocks, Fuse Blocks and Fuse Holders
IEC—XB Series
Technical Data and Specifications
Screw Connection Single Level—Through-Feed
Dimensions
Approximate Dimensions in Inches (mm)
Screw Connection Single Level—Through-Feed
Notes
1XBUT35 has an enclosed design. The use of an end cover is not required.
2For information on Printed Marking Tag Options, see Page V7-T8-98.
Description XBUT25 XBUT4 XBUT6 XBUT10 XBUT16 XBUT35
Technical Data in Accordance with IEC
Maximum load current in A/cross-section in mm232/4 41/6 57/10 76/16 101/25 150/50
Rated surge voltage in kV/contamination class 8/3 8/3 8/3 8/3 8/3 8/3
Surge voltage category/insulating material group III/II III/I III/I III/I III/I III/I
Connection Capacity
Stranded with ferrule/with ferrule and
plastic sleeve in mm2
0.25–2.5/0.25–2.5 0.25–4/0.25–4 0.25–6/0.25–6 0.5–10/0.5–10 1.0–16/1.0–16 1.5–35/1.5–35
Multi-Conductor Connection
(same cross-section)
Solid/stranded in mm20.14–1.5/0.14–1.5 0.14–1.5/0.14–1.5 0.2–2.5/0.2–2.5 0.5–4/0.5–4 1.0–6/1.0–4 1.5–16/1.5–10
Stranded with ferrules without plastic sleeve in mm20.25–1.5 0.25–1.5 0.25–1.5 0.5–2.5 1.0–4 1.5–10
Stranded with twin ferrule with plastic sleeve in mm20.5–1.5 0.5–2.5 0.5–4 0.5–6 0.75–10 1.5–10
Stripping length in inches (mm) 0.35 (9) 0.35 (9) 0.39 (10) 0.39 (10) 0.39 (10) 0.63 (16)
Thread M3 M3 M4 M4 M5 M6
Torque in in-lb (Nm) 5.3–7.1 (0.6–0.8) 5.3–7.1 (0.6–0.8) 13.3–15.9 (1.5–1.8) 13.3–15.9 (1.5–1.8) 22.1–26.6 (2.5–3) 28.3–32.7 (3.2–3.7)
Catalog
Number Width Length
Cover
Width
Height for—
35 x 7.5 in 35 x 15 in
XBUT25 0.20 (5.2) 1.85 (46.9) 0.09 (2.2) 1.87 (47.5) 2.17 (55.0)
XBUT4 0.24 (6.2) 1.85 (46.9) 0.09 (2.2) 1.87 (47.5) 2.17 (55.0)
XBUT6 0.32 (8.2) 1.85 (46.9) 0.09 (2.2) 1.87 (47.5) 2.17 (55.0)
XBUT10 0.40 (10.2) 1.85 (46.9) 0.09 (2.2) 1.87 (47.5) 2.17 (55.0)
XBUT16 0.47 (12.0) 2.08 (52.8) 0.09 (2.2) 2.16 (54.8) 2.45 (62.3)
XBUT35 0.63 (16.0) 2.37 (60.2) 2.59 (65.7) 2.88 (73.2)
V7-T8-10 Volume 7—Logic Control, Operator Interface and Connectivity Solutions CA08100008E—November 2011 www.eaton.com
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8.1
Terminal Blocks, Fuse Blocks and Fuse Holders
IECXB Series
Single Level—Ground Blocks
Contents
Description Page
Single Level—Through-Feed . . . . . . . . . . . . . . . . . V7-T8-5
Single Level—Ground Blocks
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . V7-T8-11
Technical Data and Specifications . . . . . . . . . . V7-T8-11
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . V7-T8-11
Multi-Conductor Terminal Blocks . . . . . . . . . . . . . V7-T8-12
Multi-Conductor Ground Blocks . . . . . . . . . . . . . . V7-T8-14
Double Level . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V7-T8-16
Triple Level Sensor/Actuator . . . . . . . . . . . . . . . . . V7-T8-18
Fuse Terminal Blocks . . . . . . . . . . . . . . . . . . . . . . . V7-T8-21
Disconnect and Component Terminal Blocks . . . . V7-T8-24
High Current Blocks . . . . . . . . . . . . . . . . . . . . . . . V7-T8-27
Mini Screw Connection . . . . . . . . . . . . . . . . . . . . . V7-T8-29
Single Level—Ground Blocks
Product Description
The ground terminal blocks
have the same shape and
pitch as the standard terminal
block, in a green-yellow
housing. They easily snap
onto the DIN rail to make a
reliable mechanical and
electrical contact that meets
all requirements of IEC 60-
947-7-2.
Product Selection
Screw Connection Single Level—Ground Blocks
Note
1 EU type—examination certificate number: KEMA 05ATEX2158 U.
Terminal
Width
Maximum
Wire Size
IEC 60 947-7-1
in V/A/AWG
EN 50 019 1
in V/A/AWG
UL-cUL Ratings
in V/A/AWG Color
Standard
Pack
Catalog
Number
5.2 mm 12 AWG/2.5 mm2—/—/26–12 —/—/26–12 —/—/26–12 Green/Yellow 50 XBUT25PE
6.2 mm 10 AWG/4 mm2—/—/26–10 —/—/26–10 —/—/26–10 Green/Yellow 50 XBUT4PE
8.2 mm 8 AWG/6 mm2—/—/24–8 —/—/24–8 —/—/24–8 Green/Yellow 50 XBUT6PE
10.2 mm 6 AWG/10 mm2—/76/20–6 —/54/69/20–6 —/—/20–6 Green/Yellow 50 XBUT10PE
12 mm 4 AWG/16 mm2—/101/15–4 —/—/16–4 Green/Yellow 50 XBUT16PE
16 mm 2 AWG/35 mm2—/125/15–2 —/—/14–1/0 Green/Yellow 50 XBUT35PE
XBUT6PE
Volume 7—Logic Control, Operator Interface and Connectivity Solutions CA08100008E—November 2011 www.eaton.com V7-T8-11
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8.1
Terminal Blocks, Fuse Blocks and Fuse Holders
IEC—XB Series
Accessories
Screw Connection Single Level—Ground Blocks
Technical Data and Specifications
Screw Connection Single Level—Ground Blocks
Dimensions
Approximate Dimensions in Inches (mm)
Screw Connection Single Level—Ground Blocks
Notes
1For ordering information, see Page V7-T8-105.
2For information on Printed Marking Tag Options, see Page V7-T8-98.
3XBUT35PE has an enclosed design. The use of an end cover is not required.
For additional accessories, see Page V7-T8-90.
Description Color
Number of
Positions
Standard
Pack
XBUT25PE XBUT4PE XBUT6PE XBUT10PE XBUT16PE XBUT35PE
Catalog
Number
Catalog
Number
Catalog
Number
Catalog
umber
Catalog
Number
Catalog
Number
End cover Gray 10 XBACUT10 XBACUT10 XBACUT10 XBACUT10 XBACUT16 3
Partition plate 10 XBATUT10 XBATUT10 XBATUT10 XBATUT10
Plug-in bridge—
for cross connections
in the bridge shaft
Red 2 10 XBAFBS25 XBAFBS26 XBAFBS28 XBAFBS210 XBAFBS212 XBAFBS212
310XBAFBS35 XBAFBS36
510XBAFBS55 XBAFBS56
10 10 XBAFBS105 XBAFBS106
50 10 XBAFBS505 XBAFBS506
Test adapter 10 XBATSPAI4 XBATSPAI4 XBATSPAI4
2.3 mm diameter test plug XBATSMPS-_ 1XBATSMPS-_ 1—— ——
Modular test plug 10 XBATSPS5 XBATSPS6 XBATSPS8
Blank marker strip (strip of 10) White 10 XBMZB5 2XBMZB6 2XBMZB8 2XBMZB10 2XBMZB12 2XBMZB15 2
Description XBUT25PE XBUT4PE XBUT6PE XBUT10PE XBUT16PE XBUT35PE
Technical Data in Accordance with IEC
Maximum load current in A/cross-section in mm2———76/16101/25125/50
Rated surge voltage in kV/contamination class 8/3 8/3 8/3 8/3 8/3 8/3
Surge voltage category/insulating material group III/II III/I III/I III/I III/I III/I
Connection Capacity
Stranded with ferrule/with ferrule and
plastic sleeve in mm2
0.25–2.5/0.25–2.5 0.25–4/0.25–4 0.25–6/0.25–6 0.5–10/0.5–10 1.0–16/1.0–16 1.5–35/1.5–35
Multi-Conductor Connection
(same cross-section)
Solid/stranded in mm20.14–1.5/0.14–1.5 0.14–1.5/0.14–1.5 0.2–2.5/0.2–2.5 0.5–4/0.5–4 1.0–6/1.0–4 1.5–16/1.5–10
Stranded with ferrules without plastic sleeve in mm20.25–1.5 0.25–1.5 0.25–1.5 0.5–2.5 1.0–4 1.5–10
Stranded with twin ferrule with plastic sleeve in mm20.5–1.5 0.5–2.5 0.5–4 0.5–6 0.75–10 1.5–10
Stripping length in inches (mm) 0.35 (9) 0.35 (9) 0.39 (10) 0.39 (10) 0.39 (10) 0.63 (16)
Thread M3 M3 M4 M4 M5 M6
Torque in in-lb (Nm) 5.3–7.1 (0.6–0.8) 5.3–7.1 (0.6–0.8) 13.3–15.9 (1.5–1.8) 13.3–15.9 (1.5–1.8) 22.1–26.6 (2.5–3) 28.3–32.7 (3.2–3.7)
Catalog
Number Width Length
Cover
Width
Height for—
35 x 7.5 in 35 x 15 in
XBUT25PE 0.20 (5.2) 1.85 (46.9) 0.09 (2.2) 1.87 (47.5) 2.17 (55.0)
XBUT4PE 0.24 (6.2) 1.85 (46.9) 0.09 (2.2) 1.87 (47.5) 2.17 (55.0)
XBUT6PE 0.32 (8.2) 1.85 (46.9) 0.09 (2.2) 1.87 (47.5) 2.17 (55.0)
XBUT10PE 0.40 (10.2) 1.85 (46.9) 0.09 (2.2) 1.87 (47.5) 2.17 (55.0)
XBUT16PE 0.47 (12.0) 2.08 (52.8) 0.09 (2.2) 2.16 (54.8) 2.45 (62.3)
XBUT35PE 0.63 (16.0) 2.37 (60.2) 2.59 (65.7) 2.88 (73.2)
V7-T8-12 Volume 7—Logic Control, Operator Interface and Connectivity Solutions CA08100008E—November 2011 www.eaton.com
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8.1
Terminal Blocks, Fuse Blocks and Fuse Holders
IECXB Series
Multi-Conductor Terminal Blocks
Contents
Description Page
Single Level—Through-Feed . . . . . . . . . . . . . . . . . V7-T8-5
Single Level—Ground Blocks . . . . . . . . . . . . . . . . V7-T8-10
Multi-Conductor Terminal Blocks
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . V7-T8-13
Technical Data and Specifications . . . . . . . . . . V7-T8-13
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . V7-T8-13
Multi-Conductor Ground Blocks . . . . . . . . . . . . . . V7-T8-14
Double Level . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V7-T8-16
Triple Level Sensor/Actuator . . . . . . . . . . . . . . . . . V7-T8-18
Fuse Terminal Blocks . . . . . . . . . . . . . . . . . . . . . . . V7-T8-21
Disconnect and Component Terminal Blocks . . . . V7-T8-24
High Current Blocks . . . . . . . . . . . . . . . . . . . . . . . V7-T8-27
Mini Screw Connection . . . . . . . . . . . . . . . . . . . . . V7-T8-29
Multi-Conductor Terminal Blocks
Product Description
The multi-conductor terminal
blocks offer a space-saving
alternative to standard feed-
through terminal blocks
allowing for high density
wiring. Often, three
connections have to be led
to one terminal block. The
XBUT…D12 terminal block
accomplishes this without
any additional terminal blocks
or bridging required.
The XBUT…D22 terminal
blocks allow four wires to be
connected to one potential—
and can therefore be used as
compact power distributors.
Product Selection
Screw Connection Multi-Conductor Terminal Blocks, Three-Wire
Screw Connection Multi-Conductor Terminal Blocks, Four-Wire
Terminal
Width
Maximum
Wire Size
IEC 60 947-7-1
in V/A/AWG
UL-cUL Ratings
in V/A/AWG Color
Standard
Pack
Catalog
Number
5.2 mm 12 AWG/2.5 mm2500/28/26–12 150/20/26–12 Gray 50 XBUT25D12
Blue 50 XBUT25D12BU
6.2 mm 10 AWG/4 mm2500/39/26–10 150/30/26–10 Gray 50 XBUT4D12
Blue 50 XBUT4D12BU
Terminal
Width
Maximum
Wire Size
IEC 60 947-7-1
in V/A/AWG
UL-cUL Ratings
in V/A/AWG Color
Standard
Pack
Catalog
Number
5.2 mm 12 AWG/2.5 mm2500/28/26–12 150/20/26–12 Gray 50 XBUT25D22
Blue 50 XBUT25D22BU
6.2 mm 10 AWG/4 mm2500/39/26–10 150/30/26–10 Gray 50 XBUT4D22
Blue 50 XBUT4D22BU
XBUT25D12
XBUT4D22
Volume 7—Logic Control, Operator Interface and Connectivity Solutions CA08100008E—November 2011 www.eaton.com V7-T8-13
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8.1
Terminal Blocks, Fuse Blocks and Fuse Holders
IEC—XB Series
Accessories
Screw Connection Multi-Conductor Terminal Blocks
Technical Data and Specifications
Screw Connection Multi-Conductor Terminal Blocks
Dimensions
Approximate Dimensions in Inches (mm)
Screw Connection Multi-Conductor Terminal Blocks
Notes
1For ordering information, see Page V7-T8-105.
2For information on Printed Marking Tag Options, see Page V7-T8-98.
For additional accessories, see Page V7-T8-90.
Description Color
Number of
Positions
Standard
Pack
XBUT25D12 XBUT4D12 XBUT25D22 XBUT4D22
Catalog
Number
Catalog
Number
Catalog
Number
Catalog
Number
End cover Gray 10 XBACUT4D12 XBACUT4D12 XBACUT4D22 XBACUT4D22
End cover segment Gray 10 XBASUT4 XBASUT4 XBASUT4 XBASUT4
Partition plate 10 XBATUTD12 XBATUTD12 XBATUTD22 XBATUTD22
Plug-in bridge—for cross
connections in the bridge shaft
Red 2 10 XBAFBS25 XBAFBS26 XBAFBS25 XBAFBS26
310XBAFBS35 XBAFBS36 XBAFBS35 XBAFBS36
510XBAFBS55 XBAFBS56 XBAFBS55 XBAFBS56
10 10 XBAFBS105 XBAFBS106 XBAFBS105 XBAFBS106
50 10 XBAFBS505 XBAFBS506 XBAFBS505 XBAFBS506
Test adapter 10 XBATSPAI4 XBATSPAI4 XBATSPAI4 XBATSPAI4
2.3 mm diameter test plug XBATSMPS-_ 1XBATSMPS-_ 1XBATSMPS-_ 1XBATSMPS-_ 1
Modular test plug 10 XBATSPS5 XBATSPS6 XBATSPS5 XBATSPS6
Blank marker strip (strip of 10) White 10 XBMZB5 2XBMZB6 2XBMZB5 2XBMZB6 2
Description XBUT25D12 XBUT4D12 XBUT25D22 XBUT4D22
Technical Data in Accordance with IEC
Maximum load current in A/cross-section in mm228/4 39/6 28/4 39/6
Rated surge voltage in kV/contamination class 6/3 6/3 6/3 6/3
Surge voltage category/insulating material group III/I III/I III/I III/I
Connection Capacity
Stranded with ferrule/with ferrule and
plastic sleeve in mm2
0.25–2.5/0.25–2.5 0.25–4/0.25–4 0.25–2.5/0.25–2.5 0.25–4/0.25–4
Multi-Conductor Connection
(same cross-section)
Solid/stranded in mm20.14–1.0/0.14–1.0 0.14–1.0/0.14–1.5 0.14–1.0/0.14–1.0 0.14–1/0.14–1.5
Stranded with ferrules without plastic sleeve in mm20.25–1.0 0.25–1.5 0.25–1.0 0.25–1.5
Stranded with twin ferrule with plastic sleeve in mm20.5–1.0 0.5–1.0 0.5–1.0 0.5–1.0
Stripping length in inches (mm) 0.31 (8) 0.31 (8) 0.31 (8) 0.31 (8)
Thread M3 M3 M3 M3
Torque in in-lb (Nm) 5.3–7.1 (0.6–0.8) 5.3–7.1 (0.6–0.8) 5.3–7.1 (0.6–0.8) 5.3–7.1 (0.6–0.8)
Catalog
Number Width Length
Cover
Width
Height for—
35 x 7.5 in 35 x 15 in
XBUT25D12 0.20 (5.2) 2.24 (56.8) 0.09 (2.2) 1.87 (47.5) 2.17 (55.0)
XBUT4D12 0.24 (6.2) 2.24 (56.8) 0.09 (2.2) 1.87 (47.5) 2.17 (55.0)
XBUT25D22 0.20 (5.2) 2.52 (64.1) 0.09 (2.2) 1.87 (47.5) 2.17 (55.0)
XBUT4D22 0.24 (6.2) 2.52 (64.1) 0.09 (2.2) 1.87 (47.5) 2.17 (55.0)
V7-T8-14 Volume 7—Logic Control, Operator Interface and Connectivity Solutions CA08100008E—November 2011 www.eaton.com
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8.1
Terminal Blocks, Fuse Blocks and Fuse Holders
IECXB Series
Multi-Conductor Ground Blocks
Contents
Description Page
Single Level—Through-Feed . . . . . . . . . . . . . . . . . V7-T8-5
Single Level—Ground Blocks . . . . . . . . . . . . . . . . V7-T8-10
Multi-Conductor Terminal Blocks . . . . . . . . . . . . . V7-T8-12
Multi-Conductor Ground Blocks
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . V7-T8-15
Technical Data and Specifications . . . . . . . . . . V7-T8-15
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . V7-T8-15
Double Level . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V7-T8-16
Triple Level Sensor/Actuator . . . . . . . . . . . . . . . . . V7-T8-18
Fuse Terminal Blocks . . . . . . . . . . . . . . . . . . . . . . . V7-T8-21
Disconnect and Component Terminal Blocks . . . . V7-T8-24
High Current Blocks . . . . . . . . . . . . . . . . . . . . . . . V7-T8-27
Mini Screw Connection . . . . . . . . . . . . . . . . . . . . . V7-T8-29
Multi-Conductor Ground Blocks
Product Description
The ground terminal blocks
have the same shape and
pitch as the standard terminal
block, in a green-yellow
housing. They easily snap
onto the DIN rail to make
a reliable mechanical and
electrical contact that
meets all requirements
of IEC 60-947-7-2.
Product Selection
Screw Connection Multi-Conductor Ground Blocks—Three-Wire
Screw Connection Multi-Conductor Ground Blocks—Four-Wire
Terminal
Width
Maximum
Wire Size
IEC 60 947-7-1
in V/A/AWG
UL-cUL Ratings
in V/A/AWG Color
Standard
Pack
Catalog
Number
5.2 mm 12 AWG/2.5 mm2—/—/26–12 —/—/26–12 Green/Yellow 50 XBUT25D12PE
6.2 mm 10 AWG/4 mm2—/—/26–10 —/—/26–10 Green/Yellow 50 XBUT4D12PE
Terminal
Width
Maximum
Wire Size
IEC 60 947-7-1
in V/A/AWG
UL-cUL Ratings
in V/A/AWG Color
Standard
Pack
Catalog
Number
5.2 mm 12 AWG/2.5 mm2—/—/26–12 —/—/26–12 Green/Yellow 50 XBUT25D22PE
6.2 mm 10 AWG/4 mm2—/—/26–10 —/—/26–10 Green/Yellow 50 XBUT4D22PE
XBUT4D12PE
XBUT25D22PE
Volume 7—Logic Control, Operator Interface and Connectivity Solutions CA08100008E—November 2011 www.eaton.com V7-T8-15
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8.1
Terminal Blocks, Fuse Blocks and Fuse Holders
IEC—XB Series
Accessories
Screw Connection Multi-Conductor Ground Blocks
Technical Data and Specifications
Screw Connection Multi-Conductor Ground Blocks
Dimensions
Approximate Dimensions in Inches (mm)
Screw Connection Multi-Connector Ground Blocks
Notes
1For ordering information, see Page V7-T8-105.
2For information on Printed Marking Tag Options, see Page V7-T8-98.
For additional accessories, see Page V7-T8-90.
Description Color
Number of
Positions
Standard
Pack
XBUT25D12PE XBUT4D12PE XBUT25D22PE XBUT4D22PE
Catalog
Number
Catalog
Number
Catalog
Number
Catalog
Number
End cover Gray 10 XBACUT4D12 XBACUT4D12 XBACUT4D22 XBACUT4D22
End cover segment Gray 10 XBASUT4 XBASUT4 XBASUT4 XBASUT4
Partition plate 10 XBATUTD12 XBATUTD12 XBATUTD22 XBATUTD22
Plug-in bridge—for cross
connections in the bridge shaft
Red 2 10 XBAFBS25 XBAFBS26 XBAFBS25 XBAFBS26
310XBAFBS35 XBAFBS36 XBAFBS35 XBAFBS36
510XBAFBS55 XBAFBS56 XBAFBS55 XBAFBS56
10 10 XBAFBS105 XBAFBS106 XBAFBS105 XBAFBS106
50 10 XBAFBS505 XBAFBS506 XBAFBS505 XBAFBS506
Test adapter 10 XBATSPAI4 XBATSPAI4 XBATSPAI4 XBATSPAI4
2.3 mm diameter test plug XBATSMPS-_ 1XBATSMPS-_ 1XBATSMPS-_ 1XBATSMPS-_ 1
Modular test plug 10 XBATSPS5 XBATSPS6 XBATSPS5 XBATSPS6
Blank marker strip (strip of 10) White 10 XBMZB5 2XBMZB6 2XBMZB5 2XBMZB6 2
Description XBUT25D12PE XBUT4D12PE XBUT25D22PE XBUT4D22PE
Technical Data in Accordance with IEC
Maximum load current in A/cross-section in mm2————
Rated surge voltage in kV/contamination class 6/3 6/3 6/3 6/3
Surge voltage category/insulating material group III/I III/I III/I III/I
Connection Capacity
Stranded with ferrule/with ferrule and
plastic sleeve in mm2
0.25–2.5/0.25–2.5 0.25–4/0.25–4 0.25–2.5/0.25–2.5 0.25–4/0.25–4
Multi-Conductor Connection
(same cross-section)
Solid/stranded in mm20.14–1.0/0.14–1.0 0.14–1.0/0.14–1.5 0.14–1.0/0.14–1.0 0.14–1.0/0.14–1.5
Stranded with ferrules without plastic sleeve in mm20.25–1.0 0.25–1.5 0.25–1.0 0.25–1.5
Stranded with twin ferrule with plastic sleeve in mm20.5–1.0 0.5–1.0 0.5–1 0.5–1
Stripping length in inches (mm) 0.31 (8) 0.31 (8) 0.31 (8) 0.31 (8)
Thread M3 M3 M3 M3
Torque in in-lb (Nm) 5.3–7.1 (0.6–0.8) 5.3–7.1 (0.6–0.8) 5.3–7.1 (0.6–0.8) 5.3–7.1 (0.6–0.8)
Catalog
Number Width Length
Cover
Width
Height for—
35 x 7.5 in 35 x 15 in
XBUT25D12PE 0.20 (5.2) 2.24 (56.8) 0.09 (2.2) 1.87 (47.5) 2.17 (55.0)
XBUT4D12PE 0.20 (5.2) 2.24 (56.8) 0.09 (2.2) 1.87 (47.5) 2.17 (55.0)
XBUT25D22PE 0.20 (5.2) 2.52 (64.1) 0.09 (2.2) 1.87 (47.5) 2.17 (55.0)
XBUT4D22PE 0.24 (6.2) 2.52 (64.1) 0.09 (2.2) 1.87 (47.5) 2.17 (55.0)
V7-T8-16 Volume 7—Logic Control, Operator Interface and Connectivity Solutions CA08100008E—November 2011 www.eaton.com
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8.1
Terminal Blocks, Fuse Blocks and Fuse Holders
IECXB Series
Double Level
Contents
Description Page
Single Level—Through-Feed . . . . . . . . . . . . . . . . . V7-T8-5
Single Level—Ground Blocks . . . . . . . . . . . . . . . . V7-T8-10
Multi-Conductor Terminal Blocks . . . . . . . . . . . . . V7-T8-12
Multi-Conductor Ground Blocks . . . . . . . . . . . . . . V7-T8-14
Double Level
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . V7-T8-17
Technical Data and Specifications . . . . . . . . . . V7-T8-17
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . V7-T8-17
Triple Level Sensor/Actuator . . . . . . . . . . . . . . . . . V7-T8-18
Fuse Terminal Blocks . . . . . . . . . . . . . . . . . . . . . . . V7-T8-21
Disconnect and Component Terminal Blocks . . . . V7-T8-24
High Current Blocks . . . . . . . . . . . . . . . . . . . . . . . V7-T8-27
Mini Screw Connection . . . . . . . . . . . . . . . . . . . . . V7-T8-29
Double Level
Product Description
The potentials of the XBUTT
double-level terminal blocks
are on two levels to reduce
space requirements by 50%
over single-level terminal
blocks. The XBUTT Series can
be bridged on both levels for
maximum flexibility. Marking
can be provided at each
termination point.
Product Selection
Screw Connection Double Level Blocks, XBUTT4
Screw Connection Double Level Ground Block, XBUTT4PE
Terminal
Width
Maximum
Wire Size
IEC 60 947-7-1
in V/A/AWG
UL-cUL Ratings
in V/A/AWG Color
Standard
Pack
Catalog
Number
Screw Connection Double Level Blocks
6.2 mm 10 AWG/4 mm2800/36/26–10 300/30/26–10 Gray 50 XBUTT4
Blue 50 XBUTT4BU
Red 50 XBUTT4RD
Screw Connection Double Level Block (terminal block with potential distribution between the levels)
6.2 mm 10 AWG/4 mm2800/36/26–10 300/30/26–10 Gray 50 XBUTT4PV
Terminal
Width
Maximum
Wire Size
IEC 60 947-7-1
in V/A/AWG
UL-cUL Ratings
in V/A/AWG Color
Standard
Pack
Catalog
Number
Screw Connection Double Level—Ground Blocks
6.2 mm 10 AWG/4 mm2—/—/26–10 —/—/26–10 Green/Yellow 50 XBUTT4PE
XBUTT4
XBUTT4PE
Volume 7—Logic Control, Operator Interface and Connectivity Solutions CA08100008E—November 2011 www.eaton.com V7-T8-17
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8.1
Terminal Blocks, Fuse Blocks and Fuse Holders
IEC—XB Series
Accessories
Screw Connection Terminal/Ground Blocks, Double Level
Technical Data and Specifications
Screw Connection Double Level
Dimensions
Approximate Dimensions in Inches (mm)
Screw Connection Double Level
Notes
1For ordering information, see Page V7-T8-105.
2For information on Printed Marking Tag Options, see Page V7-T8-98.
For additional accessories, see Page V7-T8-90.
Description Color
Number of
Positions
Standard
Pack
XBUTT4 XBUTT4PE
Catalog
Number
Catalog
Number
End cover Gray 10 XBACUTT4 XBACUTT4
End cover segment Gray 10 XBDPUTT4 XBDPUTT4
Partition plate 10 XBATUTT4 XBATUTT4
Plug-in bridge—for cross connections in
the bridge shaft
Red 2 10 XBAFBS26 XBAFBS26
310 XBAFBS36 XBAFBS36
510 XBAFBS56 XBAFBS56
10 10 XBAFBS106 XBAFBS106
50 10 XBAFBS506 XBAFBS506
Test adapter 10 XBATSPAI4 XBATSPAI4
2.3 mm diameter test plug XBATSMPS-_ 1XBATSMPS-_ 1
Modular test plug 10 XBATSPS6 XBATSPS6
Blank marker strip (strip of 10) White 10 XBMZB6 2XBMZB6 2
Description XBUTT4 XBUTT4PE
Technical Data in Accordance with IEC
Maximum load current in A/cross-section in mm230/6 —/6
Rated surge voltage in kV/contamination class 8/3 6/3
Surge voltage category/insulating material group III/I III/I
Connection Capacity
Stranded with ferrule/with ferrule and
plastic sleeve in mm2
0.25–4/0.25–4 0.25–4/0.25–4
Multi-Conductor Connection
(same cross-section)
Solid/stranded in mm20.14–1.5/0.14–1.5 0.14–1.5/0.14–1.5
Stranded with ferrules without plastic sleeve in mm20.25–1.5 0.25–1.5
Stranded with twin ferrule with plastic sleeve in mm20.5–2.5 0.5–2.5
Stripping length in inches (mm) 0.35 (9) 0.35 (9)
Thread M3 M3
Torque in in-lb (Nm) 5.3–7.1 (0.6–0.8) 5.3–7.1 (0.6–0.8)
Catalog
Number Width Length
Cover
Width
Height for—
35 x 7.5 in 35 x 15 in
XBUTT4 0.24 (6.2) 2.75 (69.9) 0.09 (2.2) 2.56 (65.0) 2.85 (72.5)
XBUTT4PE 0.24 (6.2) 2.75 (69.9) 0.09 (2.2) 2.56 (65.0) 2.85 (72.5)
V7-T8-18 Volume 7—Logic Control, Operator Interface and Connectivity Solutions CA08100008E—November 2011 www.eaton.com
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8.1
Terminal Blocks, Fuse Blocks and Fuse Holders
IECXB Series
Triple Level Sensor/Actuator
Contents
Description Page
Single Level—Through-Feed . . . . . . . . . . . . . . . . . V7-T8-5
Single Level—Ground Blocks . . . . . . . . . . . . . . . . V7-T8-10
Multi-Conductor Terminal Blocks . . . . . . . . . . . . . V7-T8-12
Multi-Conductor Ground Blocks . . . . . . . . . . . . . . V7-T8-14
Double Level . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V7-T8-16
Triple Level Sensor/Actuator
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . V7-T8-19
Technical Data and Specifications . . . . . . . . . . V7-T8-20
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . V7-T8-20
Fuse Terminal Blocks . . . . . . . . . . . . . . . . . . . . . . . V7-T8-21
Disconnect and Component Terminal Blocks . . . . V7-T8-24
High Current Blocks . . . . . . . . . . . . . . . . . . . . . . . V7-T8-27
Mini Screw Connection . . . . . . . . . . . . . . . . . . . . . V7-T8-29
Triple Level Sensor/Actuator
Product Description
The XB3UK sensor terminal
blocks reduce installation
time by terminating three-
wire devices such as
photoelectric and proximity
sensors in a single terminal
block. The XB3UK Series
accommodates a design
where the positive and
negative connections are
grouped so that only the
signal lines and one pair of
wires for the power supply
need to be wired between
the terminal box and the
control. The upper level
accommodates the markable
feed-through terminals for
the signal line. The two lower
terminal points can be
bridged. These are used for
the sensor power supply.
The positive and negative
potential can be fed into the
bridges with XB3UKF25. The
first sensor can also be
connected to this three-wire
feed-through block.
Product Selection
Screw Connection Triple Level Sensor/Actuator
Screw Connection Triple Level Sensor/Actuator
Terminal
Width
Maximum
Wire Size
Connection Data
in V/A/AWG
IEC 60 947-7-1
in V/A/AWG
UL-cUL Ratings
in V/A/AWG Color
Standard
Pack
Catalog
Number
Screw Connection Triple Level
6.2 mm 14 AWG/2.5 mm2250/26/24–12 300/15/30–14 Gray 50 XB3UKA25
Screw Connection Triple Level with Red LED, 15–30 Vdc, 2.5–7.5A
6.2 mm 14 AWG/2.5 mm2250/26/24–12 300/15/30–14 Gray 50 XB3UKA25L24
Terminal
Width
Maximum
Wire Size
Connection Data
in V/A/AWG
IEC 60 947-7-1
in V/A/AWG
UL-cUL Ratings
in V/A/AWG Color
Standard
Pack
Catalog
Number
Screw Connection Triple Level
6.2 mm 14 AWG/2.5 mm2 250/30/24–12 300/15/30–14 Gray 50 XB3UKF25
XB3UKA25
XB3UKF25
Volume 7—Logic Control, Operator Interface and Connectivity Solutions CA08100008E—November 2011 www.eaton.com V7-T8-19
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8.1
Terminal Blocks, Fuse Blocks and Fuse Holders
IEC—XB Series
Screw Connection Triple Level Sensor/Actuator
Screw Connection Triple Level Sensor/Actuator
Accessories
Screw Connection Triple Level Sensor/Actuator
Notes
1For information on Printed Marking Tag Options, see Page V7-T8-98.
For additional accessories, see Page V7-T8-90.
Terminal
Width
Maximum
Wire Size
Connection Data
in V/A/AWG
UL-cUL Ratings
in V/A/AWG Color
Standard
Pack
Catalog
Number
Screw Connection Triple Level
6.2 mm 14 AWG/2.5 mm2250/26/24–12 300/15/30–14 Gray 50 XB3UKA25PE
Screw Connection Triple Level with Red LED, 15–30 Vdc, 2.5–7.5A
6.2 mm 14 AWG/2.5 mm2250/26/24–12 300/15/30–14 Gray 50 XB3UKA25PEL24
Terminal
Width
Maximum
Wire Size
Connection Data
in V/A/AWG
UL-cUL Ratings
in V/A/AWG Color
Standard
Pack
Catalog
Number
Screw Connection Triple Level
6.2 mm 14 AWG/2.5 mm2 300/15/30–14 Gray 50 XB3UKF25PE
Description Color
Number of
Positions
Standard
Pack
XB3UKA25 XB3UKF25 XB3UKA25PE XB3UKF25PE
Catalog
Number
Catalog
Number
Catalog
Number
Catalog
Number
Insertion bridge Blue 80 1 XBAEB80DIKB XBAEB80DIKB XBAEB80DIKB XBAEB80DIKB
Red 80 1 XBAEB80DIKR XBAEB80DIKR XBAEB80DIKR XBAEB80DIKR
Insertion bridge Blue 10 10 XBAEB10DIKB XBAEB10DIKB XBAEB10DIKB XBAEB10DIKB
Red 10 10 XBAEB10DIKR XBAEB10DIKR XBAEB10DIKR XBAEB10DIKR
Blank marker strip (strip of 10) White 10 XBMZB6 1XBMZB6 2XBMZB6 2XBMZB6 2
XB3UKA25PE
XB3UKF25PE
V7-T8-20 Volume 7—Logic Control, Operator Interface and Connectivity Solutions CA08100008E—November 2011 www.eaton.com
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8.1
Terminal Blocks, Fuse Blocks and Fuse Holders
IECXB Series
Technical Data and Specifications
Screw Connection Triple Level Sensor/Actuator
Wiring for Three-Level
Sensor Terminal Blocks
Wiring for Four-Level
Sensor Terminal Blocks
Dimensions
Approximate Dimensions in Inches (mm)
Screw Connection Triple Level Sensor/Actuator
Description XB3UKA25 XB3UKF25 XB3UKA25PE XB3UKF25PE
Technical Data in Accordance with IEC
Maximum load current in A/cross-section in mm226/2.5 30/4 26/2.5 26/2.5
Maximum cross section with insertion bridge solid/stranded in mm24/2.5 4/2.5 4/2.5 4/2.5
Rated surge voltage in kV/contamination class 4/3 4/3 4/3 6/3
Surge voltage category/insulating material group III/I III/I III/I III/I
Connection Capacity
Stranded with ferrule/with ferrule and
plastic sleeve in mm2
0.25–2.5/0.25–2.5 0.25–2.5/0.25–2.5 0.25–2.5/0.25–2.5 0.25–2.5/0.25–2.5
Multi-Conductor Connection
(same cross-section)
Solid/stranded in mm20.2–1.0/0.2–1.0 0.2–1.0/0.2–1.0 0.2–1.0/0.2–1.0 0.2–1.0/0.2–1.0
Stranded with ferrules without plastic sleeve in mm20.25–1.0 0.25–1.0 0.25–1.0 0.25–1.0
Stranded with twin ferrule with plastic sleeve in mm20.5–1.0 0.5–1.0 0.5–1.0 0.5–1.0
Stripping length in inches (mm) 0.31 (8) 0.31 (8) 0.31 (8) 0.31 (8)
Thread M3 M3 M3 M3
Torque in in-lb (Nm) 4.4–5.3 (0.5–0.6) 4.4–5.3 (0.5–0.6) 4.4–5.3 (0.5–0.6) 4.4–5.3 (0.5–0.6)
Catalog
Number Width Length
Height for—
35 x 7.5 in 35 x 15 in
XB3UKA25 0.24 (6.2) 2.17 (55.0) 2.15 (54.5) 2.44 (62.0)
XB3UKF25 0.24 (6.2) 2.85 (72.5) 2.15 (54.5) 2.44 (62.0)
XB3UKA25PE 0.24 (6.2) 2.46 (62.5) 2.76 (70.0) 3.05 (77.5)
XB3UKF25PE 0.24 (6.2) 3.25 (82.5) 2.76 (70.0) 3.05 (77.5)
Volume 7—Logic Control, Operator Interface and Connectivity Solutions CA08100008E—November 2011 www.eaton.com V7-T8-21
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8.1
Terminal Blocks, Fuse Blocks and Fuse Holders
IEC—XB Series
Fuse Terminal Blocks
Contents
Description Page
Single Level—Through-Feed . . . . . . . . . . . . . . . . . V7-T8-5
Single Level—Ground Blocks . . . . . . . . . . . . . . . . V7-T8-10
Multi-Conductor Terminal Blocks . . . . . . . . . . . . . . V7-T8-12
Multi-Conductor Ground Blocks . . . . . . . . . . . . . . V7-T8-14
Double Level. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V7-T8-16
Triple Level Sensor/Actuator . . . . . . . . . . . . . . . . . V7-T8-18
Fuse Terminal Blocks
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . V7-T8-23
Technical Data and Specifications . . . . . . . . . . V7-T8-23
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . V7-T8-23
Disconnect and Component Terminal Blocks . . . . V7-T8-24
High Current Blocks . . . . . . . . . . . . . . . . . . . . . . . . V7-T8-27
Mini Screw Connection . . . . . . . . . . . . . . . . . . . . . V7-T8-29
Fuse Terminal Blocks
Product Description
The UT Series fuse terminal
blocks come in two varieties—
lever type and cap. Each
performs two functions. They
act as a fuse carrier for most
common North American and
European fuses and they
allow for potential distribution
with the double bridge shaft.
The terminal blocks therefore
allow bypass routing of two
separate potentials next to
each other. This has the
advantage of a time-saving
potential infeed and a correct,
functional configuration of the
terminal strip. For signaling a
triggered fuse, fuse terminal
blocks with light indicators
are available (for both AC and
DC voltage).
Product Selection
Screw Connection Fuse Terminal Blocks, for 5 x 20 mm Fuse
Note
1 As disconnect terminal block 400V, as fuse terminal block 250V.
Terminal
Width
Maximum
Wire Size
IEC 60 947-7-3
in V/A/AWG
UL-cUL Ratings
in V/A/AWG Color
Standard
Pack
Catalog
Number
Fuse Terminal Blocks
6.2 mm 10 AWG/4 mm21/6.3/26–10 600/6.3/26–10 Black 50 XBUT4FBE
Fuse Terminal Blocks with LED 12–30V, 1–2.5 mA
6.2 mm 10 AWG/4 mm21/6.3/26–10 600/6.3/26–10 Black 50 XBUT4FBEL24
Fuse Terminal Blocks with LED 30–60V, 0.8–2.0 mA
6.2 mm 10 AWG/4 mm21/6.3/26–10 600/6.3/26–10 Black 50 XBUT4FBEL60
Fuse Terminal Blocks with LED 110–250V, 0.5–2.5 mA
6.2 mm 10 AWG/4 mm21/6.3/26–10 600/6.3/26–10 Black 50 XBUT4FBEL250
XBUT4FBE
V7-T8-22 Volume 7—Logic Control, Operator Interface and Connectivity Solutions CA08100008E—November 2011 www.eaton.com
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8.1
Terminal Blocks, Fuse Blocks and Fuse Holders
IECXB Series
Screw Connection Fuse Terminal Blocks for 6.3 x 32 mm (1/4 in x 1–1/4 in) Fuse
Screw Connection Fuse Terminal Blocks, XBUK10FBC
Cartridge Fuse Inserts 5 x 20 mm Based on DIN EN 60 947-7-3: 2003-7
Notes
Max. power dissipation at 73.4°F (23°C) based on DIN EN 60 947-7-3: 2003-7.
When selecting cartridge fuse inserts, please ensure that the maximum power dissipation specified above
is not exceeded. Details can be obtained from the fuse suppliers.
If the fuse is defective, the downstream circuit is not off load.
1 As disconnect terminal block 500V, as fuse terminal block 400V.
Terminal
Width
Maximum
Wire Size
IEC 60 947-7-3
in V/A/AWG
UL-cUL Ratings
in V/A/AWG Color
Standard
Pack
Catalog
Number
Fuse Terminal Blocks
8.2 mm 8 AWG/6 mm21/10/24–8 400/10/24–8 Black 50 XBUT6FBN
Fuse Terminal Blocks with LED 12–30V, 1–2.5 mA
8.2 mm 8 AWG/6 mm21/10/24–8 400/10/24–8 Black 50 XBUT6FBNL24
Fuse Terminal Blocks with LED 30–60V, 0.8–2.0 mA
8.2 mm 8 AWG/6 mm21/10/24–8 400/10/24–8 Black 50 XBUT6FBNL60
Fuse Terminal Blocks with LED 110–250V, 0.5–2.5 mA
8.2 mm 8 AWG/6 mm21/10/24–8 400/10/24–8 Black 50 XBUT6FBNL250
Terminal
Width
Maximum
Wire Size
IEC 60 947-7-3
with Fuse in
V/A/AWG
IEC 60 947-7-3
as Disconnected
t.b. in V/A/AWG
UL-cUL Ratings
in V/A/AWG Color
Standard
Pack
Catalog
Number
Fuse Terminal Blocks for 5 x 20 mm fuse
12 mm 6 AWG/16 mm21/1/20–4 800/10/20–6 300/20/22–6 Black 50 XBUK10FBCE
Fuse Terminal Blocks for 6.3 x 32 mm (1/4 in x 1–1/4 in) fuse
12 mm 6 AWG/16 mm21/1/20–4 800/10/20–6 300/20/22–6 Black 50 XBUK10FBCN
Fuse Terminal Blocks with Light Indicator 15–30V, 1–2.5 mA, 5 x 20 mm
12 mm 6 AWG/16 mm21/1/20–4 800/10/20–6 300/20/22–6 Black 50 XBUK10FBCEL24
Fuse Terminal Blocks with Light Indicator 15–30V, 1–2.5 mA, 6.3 x 32 mm
12 mm 6 AWG/16 mm21/1/20–4 800/10/20–6 300/20/22–6 Black 50 XBUK10FBCNL24
Fuse Terminal Blocks with Light Indicator 110–250V, 0.5–1.1A, 5 x 20 mm
12 mm 6 AWG/16 mm21/1/20–4 800/10/20–6 300/20/22–6 Black 50 XBUK10FBCEL250
Fuse Terminal Blocks with Light Indicator 110–250V, 0.5–1.1A, 6.3 x 32 mm
12 mm 6 AWG/16 mm21/1/20–4 800/10/20–6 300/20/22–6 Black 50 XBUK10FBCNL250
Terminal
Blocks U (V)
Overload Protection Short-Circuit Protection Only
Individual Interconnected Individual Interconnected Imax. (A)
XBUT4FBE 250 1.6W 1.6W 4W 2.5W 6.3
XBUT6FBN
XBUK10FBCE
Volume 7—Logic Control, Operator Interface and Connectivity Solutions CA08100008E—November 2011 www.eaton.com V7-T8-23
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8.1
Terminal Blocks, Fuse Blocks and Fuse Holders
IEC—XB Series
Accessories
Screw Connection Fuse Terminal Blocks
Technical Data and Specifications
Screw Connection Fuse Terminal Blocks
Dimensions
Approximate Dimensions in Inches (mm)
Screw Connection Fuse Terminal Blocks
Notes
1XBUT4FBE and XBUT6FBN have an enclosed design. The use of an end cover is not required.
2For information on Printed Marking Tag Options, see Page V7-T8-98.
For additional accessories, see Page V7-T8-90.
Description Color
Number of
Positions
Standard
Pack
XBUT4FBE XBUT6FBN XBUK10FBCE
Catalog
Number
Catalog
Number
Catalog
Number
End cover 11
Plug-in bridge—for cross connections in
the bridge shaft
Red 2 10 XBAFBS26 XBAFBS28
310XBAFBS36 XBAFBS38
510XBAFBS56 XBAFBS58
10 10 XBAFBS106 XBAFBS108
50 10 XBAFBS506
Blank marker strip center labeling (strip of 10) White XBMZB5 2XBMZB6 2
Blank marker strip external labeling (strip of 10) White XBMZB6 2XBMZB8 2
Fixed bridge 2 10 XBAFBI212
Screw heads with insulating collar 10 10 XBAFBI1012
Blank marker strip (strip of 10) White 10 —— XBMZB6
2
Description XBUT4FBE XBUT4FBN XBUK10FBCE
Technical Data in Accordance with IEC
Fuse type/dimensions in (mm) G/5 x 20/5 x 25/6.3 x 32
Maximum cross section with insertion bridge solid/stranded in mm26.3/6 10/10 10/10
Rated surge voltage in kV/contamination class 4/3 4/3 4/3
Surge voltage category/insulating material group III/II III/II III/I
Connection Capacity
Stranded with ferrule/with ferrule and plastic sleeve in mm20.25–4/0.25–4 0.25–6/0.25–6 0.5–10/0.5–10
Multi-Conductor Connection (same cross-section)
Solid/stranded in mm20.14–1.5/0.14–1.5 0.5–4/0.5–4
Stranded with ferrules without plastic sleeve in mm20.25–1.5 0.5–4
Stranded with twin ferrule with plastic sleeve in mm20.5–2.5 0.5–4 0.5–10
Stripping length in inches (mm) 0.35 (9) 0.39 (10) 0.43 (11)
Thread M3 M4 M4
Torque in in-lb (Nm) 5.3–7.1 (0.6–0.8) 13.3–15.9 (1.5–1.8) 13.3–15.9 (1.5–1.8)
Catalog
Number Width Length
Height for—
35 x 7.5 in 35 x 15 in 32 in
XBUT4FBE 0.24 (6.2) 2.24 (56.8) 2.87 (73.0) 3.17 (80.5)
XBUT4FBN 0.32 (8.2) 2.24 (56.8) 2.87 (73.0) 3.17 (80.5)
XBUK10FBCE 0.47 (12.0) 2.44 (62.0) 2.32 (59.0) 2.62 (66.5) 2.52 (64.0)
V7-T8-24 Volume 7—Logic Control, Operator Interface and Connectivity Solutions CA08100008E—November 2011 www.eaton.com
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8.1
Terminal Blocks, Fuse Blocks and Fuse Holders
IECXB Series
Disconnect and Component Terminal Blocks
Contents
Description Page
Single Level—Through-Feed . . . . . . . . . . . . . . . . . V7-T8-5
Single Level—Ground Blocks . . . . . . . . . . . . . . . . V7-T8-10
Multi-Conductor Terminal Blocks . . . . . . . . . . . . . V7-T8-12
Multi-Conductor Ground Blocks . . . . . . . . . . . . . . V7-T8-14
Double Level . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V7-T8-16
Triple Level Sensor/Actuator . . . . . . . . . . . . . . . . . V7-T8-18
Fuse Terminal Blocks . . . . . . . . . . . . . . . . . . . . . . . V7-T8-21
Disconnect and Component Terminal Blocks
Product Selection . . . . . . . . . . . . . . . . . . . . . . . V7-T8-25
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . V7-T8-26
Technical Data and Specifications . . . . . . . . . . V7-T8-26
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . V7-T8-26
High Current Blocks . . . . . . . . . . . . . . . . . . . . . . . V7-T8-27
Mini Screw Connection . . . . . . . . . . . . . . . . . . . . . V7-T8-29
Disconnect and Component Terminal Blocks
Product Description
The XB Series includes
application specific terminal
blocks like the XBUT4TG
disconnect block that
accommodates disconnect
component and fuse terminal
blocks. It can also be bridged
with standard terminal blocks
via the double bridge shaft.
The component plug XBPCO
serves to accommodate
different components such
as resistors or capacitors.
5 x 20 mm fuses can be
inserted into the fuse plug
XBPFU, also available with
light indication. The XBUT4MT
knife disconnect terminal
block features a compact
design and a high current
carrying capacity of 16A.
Versions with test socket
screws provide a test option
for 2.3 mm diameter test
plugs on both sides of the
disconnect point.
Volume 7—Logic Control, Operator Interface and Connectivity Solutions CA08100008E—November 2011 www.eaton.com V7-T8-25
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8.1
Terminal Blocks, Fuse Blocks and Fuse Holders
IEC—XB Series
Product Selection
Screw Connection Disconnect and Component Terminal Blocks
Screw Connection Thermoelectric Voltage Terminal Blocks
Terminal
Width
Maximum
Wire Size
Connection Data
in V/A/AWG
UL-cUL Ratings
for Disconnect
in V/A/AWG
UL-cUL Ratings
for Disconnect
with Test Sockets
in V/A/AWG Color
Standard
Pack
Catalog
Number
Screw Connection Disconnect
6.2 mm 10 AWG/4 mm2500/16/26–10 600/16/26–10 300/16/26–10 Gray 50 XBUT4TG
Screw Connection Disconnect with Test Sockets
6.2 mm 10 AWG/4 mm2500/16/26–10 600/16/26–10 300/16/26–10 Gray 50 XBUT4TGP
Component Plug
6.2 mm 10 AWG/4 mm2500/16/26–10 600/16/26–10 300/16/26–10 Gray 10 XBPCO
Fuse Plug
6.2 mm 10 AWG/4 mm2500/16/26–10 600/16/26–10 300/16/26–10 Black 10 XBPFU
Fuse Plug with Light Indicator for 12–30V, 1–2.5 mA
6.2 mm 10 AWG/4 mm2500/16/26–10 600/16/26–10 300/16/26–10 Black 10 XBPFUL24
Fuse Plug with Light Indicator for 110–250V, 0.5–2.5 mA
6.2 mm 10 AWG/4 mm2500/16/26–10 600/16/26–10 300/16/26–10 Black 10 XBPFUL250
Screw Connection Disconnect Knife Disconnect
6.2 mm 10 AWG/4 mm2500/16/26–10 600/16/26–10 300/16/26–10 Gray 50 XBUT4MT
Screw Connection Disconnect Knife Disconnect with Test Sockets
6.2 mm 10 AWG/4 mm2500/16/26–10 600/16/26–10 300/16/26–10 Gray 50 XBUT4MTP
Screw Connection Terminal Blocks with Integrated Diodes
6.2 mm 12 AWG/4 mm2500/32/24–10 600/30/26–10 Gray 50 XBUKK4DIO
Terminal
Width
Maximum
Wire Size
Connection Data
in V/A/AWG
UL-cUL Ratings
in V/A/AWG Color
Standard
Pack
Catalog
Number
Copper/Constantan (CU/CUNI44)
10.4 mm 12 AWG/2.5 mm2400/—/24–12 300/10/28–12 Gray 50 XBTKT25 (Type T)
Iron/Constantan (FE/CUNI44)
10.4 mm 12 AWG/2.5 mm2400/—/24–12 300/10/28–12 Gray 50 XBTKJ25 (Type J)
Nickel-Chrome/Constantan (NICR/CUNI44)
10.4 mm 12 AWG/2.5 mm2400/—/24–12 300/10/28–12 Gray 50 XBTKE25 (Type E)
Nickel-Chrome/Nickel (NICRNI)
10.4 mm 12 AWG/2.5 mm2400/—/24–12 300/10/28–12 Gray 50 XBTKK25 (Type K)
Copper/Copper Nickel (E-CU/A-CU)
10.4 mm 12 AWG/2.5 mm2400/—/24–12 300/10/28–12 Gray 50 XBTKR25 (Type R)
XBUT4TG
Disconnect
XBTKT25 Thermal
Electric Voltage
V7-T8-26 Volume 7—Logic Control, Operator Interface and Connectivity Solutions CA08100008E—November 2011 www.eaton.com
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8.1
Terminal Blocks, Fuse Blocks and Fuse Holders
IECXB Series
Accessories
Screw Connection Disconnect and Component Terminal Blocks
Technical Data and Specifications
Screw Connection Disconnect and Component Terminal Blocks
Dimensions
Approximate Dimensions in Inches (mm)
Screw Connection Disconnect and Component Terminal Blocks
Notes
1For ordering information, see Page V7-T8-105.
2For information on Printed Marking Tag Options, see Page V7-T8-98.
For additional accessories, see Page V7-T8-90.
Description Color
Number of
Positions
Standard
Pack
XBUT4TG XBUT4MT XBUKK4DI0 XBTKT25
Catalog
Number
Catalog
Number
Catalog
Number
Catalog
Number
Plug-in bridge—for cross connections in
the bridge shaft
Red 2 10 XBAFBS26 XBAFBS26
310XBAFBS36 XBAFBS36
510XBAFBS56 XBAFBS56
10 10 XBAFBS106 XBAFBS106
50 10 XBAFBS506 XBAFBS506
Test adapter 10 XBATSPAI4 XBATSPAI4
2.3 mm diameter test plug XBATSMPS-_ 1XBATSMPS-_ 1——
Modular test plug 10 XBATSDPPS6 XBATSDPPS6
Blank marker strip (strip of 10) White 10 XBMZB6 2XBMZB6 2XBMZB6 2XBMZB10 2
End cover Gray 10 XBACUKK35 XBACTK4
Spacer cover Gray 10 XBADGUKK35
Spacer plate 10 XBADPUKK35
Partition plate XBATTK4
Fixed bridge 10 10 ——XBAFBI106
Description XBUT4TG XBUT4MT XBUKK4DI0 XBTK
Technical Data in Accordance with IEC
Maximum load current in A/cross-section in mm216/6 16/6 32/4
Rated surge voltage in kV/contamination class 6/3 6/3 6/3
Surge voltage category/insulating material group III/I III/I III/I
Connection Capacity
Stranded with ferrule/with ferrule and
plastic sleeve in mm2
0.25–4/0.25–4 0.25–4/0.25–4 0.25–4/0.25–2.5
Multi-Conductor Connection
(same cross-section)
Solid/stranded in mm20.14–1.5/0.14–1.5 0.14–1.5/0.14–1.5 0.2–1.5/0.2–1.5
Stranded with ferrules without plastic sleeve in mm20.25–1.5 0.25–1.5 0.25–1.5
Stranded with twin ferrule with plastic sleeve in mm20.5–2.5 0.5–2.5 0.5–1.5
Stripping length in inches (mm) 0.35 (9) 0.35 (9) 0.31 (8) 0.28 (7)
Thread M3 M3 M3 M3
Torque in in-lb (Nm) 5.3–7.1 (0.6–0.8) 5.3–7.1 (0.6–0.8) 5.3–7.1 (0.6–0.8) 5.3–7.1 (0.6–0.8)
Catalog
Number Width Length
Cover
Width
Height for—
35 x 7.5 in 35 x 15 in 32 in
XBUT4TG 0.24 (6.2) 2.24 (56.8) 1.87 (47.5) 2.17 (55.0)
XBUT4MT 0.24 (6.2) 2.24 (56.8) 1.87 (47.5) 2.17 (55.0)
XBUKK4DI0 0.24 (6.2) 2.20 (56.0) 0.10 (2.5) 2.44 (62.0) 2.74 (69.5) 2.64 (67.0)
XBTK 0.20 (5.2) 1.81 (46.0) 0.04 (1.0) 1.57 (40.0) 1.87 (47.5) 1.77 (45.0)
Volume 7—Logic Control, Operator Interface and Connectivity Solutions CA08100008E—November 2011 www.eaton.com V7-T8-27
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8.1
Terminal Blocks, Fuse Blocks and Fuse Holders
IEC—XB Series
High Current Blocks
Contents
Description Page
Single Level—Through-Feed . . . . . . . . . . . . . . . . . V7-T8-5
Single Level—Ground Blocks . . . . . . . . . . . . . . . . V7-T8-10
Multi-Conductor Terminal Blocks . . . . . . . . . . . . . . V7-T8-12
Multi-Conductor Ground Blocks . . . . . . . . . . . . . . V7-T8-14
Double Level. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V7-T8-16
Triple Level Sensor/Actuator . . . . . . . . . . . . . . . . . V7-T8-18
Fuse Terminal Blocks . . . . . . . . . . . . . . . . . . . . . . . V7-T8-21
Disconnect and Component Terminal Blocks . . . . V7-T8-24
High Current Blocks
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . V7-T8-28
Technical Data and Specifications . . . . . . . . . . V7-T8-28
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . V7-T8-28
Mini Screw Connection . . . . . . . . . . . . . . . . . . . . . V7-T8-29
High Current Blocks
Product Description
Eaton’s XBUK high current
terminal blocks offer a reliable
connection via the superior
construction that includes
three-point centering of the
wire in the
prism-shaped sleeve base,
a fluted contact surface
for low contact resistance,
and screws secured with
spring-loaded elements.
The terminal blocks have
an enclosed housing made
from polyamide 6.6. Green-
yellow ground terminal blocks
are also available.
Product Selection
Screw Connection High Current Blocks
Screw Connection High Current Ground Blocks
Note
1 U type—examination certificate number: KEMA 05ATEX2170 U (XBUK50), KEMA 05ATEX2171 U (XBUK150).
Terminal
Width
Maximum
Wire Size
IEC 60 947-7-1
in V/A/AWG
EN 50 019 1
in V/A/AWG
UL-cUL Ratings
in V/A/AWG Color
Standard
Pack
Catalog
Number
20.0 mm 1/0/50 mm21000/150/1/0 750/135/1/0 600/150/1/0 Gray 10 XBUK50
Blue 10 XBUK50BU
31.0 mm 300 kcmil/150 mm21000/309/2–300 726/265/2–300 600/285/
2 AWG–300 kcmil
Gray 10 XBUK150
Terminal
Width
Maximum
Wire Size
IEC 60 947-7-1
in V/A/AWG
EN 50 019 1
in V/A/AWG
UL-cUL Ratings
in V/A/AWG Color
Standard
Pack
Catalog
Number
25.0 mm 000 AWG/95 mm2—/232/4–000 —/—/4–000 —/—/2–4/0 Green/Yellow 10 XBUK95PE
XBUK150
XBUK95PE
V7-T8-28 Volume 7—Logic Control, Operator Interface and Connectivity Solutions CA08100008E—November 2011 www.eaton.com
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8.1
Terminal Blocks, Fuse Blocks and Fuse Holders
IECXB Series
Accessories
Screw Connection High Current Blocks
Technical Data and Specifications
Screw Connection High Current Blocks
Dimensions
Approximate Dimensions in Inches (mm)
Screw Connection High Current Blocks
Notes
1For information on Printed Marking Tag Options, see Page V7-T8-98.
For additional accessories, see Page V7-T8-90.
Description Color
Number of
Positions
Standard
Pack
XBUK50 XBUK150 XBUK95PE
Catalog
Number
Catalog
Number
Catalog
Number
Fixed bridge, screw heads with insulating color 2 10 XBAFBI220
Insertion bridge 2 10 XBAEB231
Blank marker strip external labeling (strip of 10) White 10 XBMZB10 1XBMZB10 1XBMZB10 1
Description XBUK50 XBUK150 XBUK95PE
Technical Data in Accordance with IEC
Maximum load current in A/cross-section in mm2150/50 309/150 232/95
Maximum cross-section with insertion bridge
solid/stranded in mm2
—/— 150/120 —/—
Rated surge voltage in kV/contamination class 8/3 8/3 8/3
Surge voltage category/insulating material group III/I III/I III/I
Connection Capacity
Stranded with ferrule/with ferrule and
plastic sleeve in mm2
25–50/25–50 50–150/50–150 35–95/35–95
Multi-Conductor Connection
(same cross-section)
Solid/stranded in mm210–16/10–16 25–50/35–50 25–35/25–35
Stranded with ferrules without plastic sleeve in mm210–16 25–50 16–35
Stripping length in inches (mm) 0.94 (24) 1.57 (40) 1.18 (30)
Thread M6 M10 M8
Terminal point—thread/torque in in-lb (Nm) 53–71 (6–8) 221–267 (25–30) 133–177 (15–20)
Fastening—thread/torque in in-lb (Nm) 53–71 (6–8) 221–267 (25–30) 133–177 (15–20)
Catalog
Number Width Length
Height for—
35 x 7.5 in 35 x 15 in 32 in
XBUK50 0.79 (20.0) 2.78 (70.5) 3.29 (83.5) 3.21 (81.5)
XBUK150 1.22 (31.0) 3.94 (100.0) 4.67 (118.5) 4.57 (116.0)
XBUK95PE 0.98 (25.0) 3.27 (83.0) 3.90 (99.0) 3.80 (96.5)
Volume 7—Logic Control, Operator Interface and Connectivity Solutions CA08100008E—November 2011 www.eaton.com V7-T8-29
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8.1
Terminal Blocks, Fuse Blocks and Fuse Holders
IEC—XB Series
Mini Screw Connection Terminal Blocks
Contents
Description Page
Single Level—Through-Feed. . . . . . . . . . . . . . . . . . V7-T8-5
Single Level—Ground Blocks . . . . . . . . . . . . . . . . V7-T8-10
Multi-Conductor Terminal Blocks . . . . . . . . . . . . . . V7-T8-12
Multi-Conductor Ground Blocks . . . . . . . . . . . . . . V7-T8-14
Double Level. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V7-T8-16
Triple Level Sensor/Actuator . . . . . . . . . . . . . . . . . V7-T8-18
Fuse Terminal Blocks . . . . . . . . . . . . . . . . . . . . . . . V7-T8-21
Disconnect and Component Terminal Blocks . . . . V7-T8-24
High Current Blocks . . . . . . . . . . . . . . . . . . . . . . . . V7-T8-27
Mini Screw Connection
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . V7-T8-30
Technical Data and Specifications . . . . . . . . . . V7-T8-30
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . V7-T8-30
Mini Screw Connection
Product Description
The XB miniature terminal
blocks have a connection
cross-section from 2 mm2
through 4 mm2 and mount on
15 mm DIN rail. There is an
opening for bridging with a
fixed bridge in the center of
the terminal blocks. These
miniature terminal blocks also
offer the same accessories
that you would find with the
larger blocks—including
marking tags, end covers,
end stop and ground blocks.
Product Selection
Mini Screw Connection Terminal Blocks
Mini Screw Connection Ground Blocks
Note
1 EU type—examination certificate number: KEMA 05ATEX2169 U (XBMUK25).
Terminal
Width
Maximum
Wire Size
IEC 60 947-7-1
in V/A/AWG
EN 50 019 1
in V/A/AWG
UL-cUL Ratings
in V/A/AWG Color
Standard
Pack
Catalog
Number
5.2 mm 12 AWG/2.5 mm2400/32/24–12 275/28/21/24–12 600/20/28–12 Gray 50 XBMUK25
Blue 50 XBMUK25BU
6.2 mm 10 AWG/4 mm2500/41/24–10 —/—/— 600/10/26–10 Gray 50 XBMUK4
Blue 50 XBMUK4BU
Terminal
Width
Maximum
Wire Size
IEC 60 947-7-2
in V/A/AWG
UL-cUL Ratings
in V/A/AWG Color
Standard
Pack
Catalog
Number
5.2 mm 12 AWG/2.5 mm2—/—/24–12 —/—/30–12 Green/
Yellow
50 XBMUK25PE
6.2 mm 10 AWG/2.4 mm2—/—/24–10 —/—/26–14 Green/
Yellow
50 XBMUK4PE
XBMUK4
XBMUK25PE
V7-T8-30 Volume 7—Logic Control, Operator Interface and Connectivity Solutions CA08100008E—November 2011 www.eaton.com
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8.1
Terminal Blocks, Fuse Blocks and Fuse Holders
IECXB Series
Accessories
Mini Screw Connection Terminal/Ground Blocks
Technical Data and Specifications
Mini Spring Cage Terminal/Ground Blocks
Dimensions
Approximate Dimensions in Inches (mm)
Mini Spring Cage Terminal/Ground Blocks
Notes
1For information on Printed Marking Tag Options, see Page V7-T8-98.
For additional accessories, see Page V7-T8-90.
Description Color
Number of
Positions
Standard
Pack
XBMUK25 XBMUK4 XBMUK25PE XBMUK4PE
Catalog
Number
Catalog
Number
Catalog
Number
Catalog
Number
End cover Gray 10 XBACMU254 XBACMU254
Blue 10 XBACMU254B XBACMU254B
Partition plate 10 XBATMU254 XBATMU254
Fixed bridge 10 10 XBAFBR105N
Separating plate 10 XBATMPKK15 XBATMPKK15
Blank marker strip (strip of 10) White 10 XBMZB5 1XBMZB6 1XBMZB5 1XBMZB6 1
Description XBMUK25 XBMUK4 XBMUK25PE XBMUK4PE
Technical Data in Accordance with IEC
Maximum load current in A/cross-section in mm232/4 41/6
Maximum cross-section with insertion bridge (solid/stranded) 2.5/2.5 4/4
Rated surge voltage in kV/contamination class 6/3 6/3 6/3 6/3
Surge voltage category/insulating material group III/I III/I III/I III/I
Connection Cross-Section
Stranded with ferrule with plastic sleeve in mm20.25–1.5 0.25–2.5 0.25–1.5 0.25–2.5
Stranded with ferrule without plastic sleeve in mm20.25–2.5 0.25–4 0.25–2.5 0.25–4
Multi-Conductor Connection (same cross-section)
Solid/stranded in mm20.2–1.0/0.2–1.5 0.2–1.5/0.2–1.5 0.2–1.0/0.2–1.5 0.2–1.5/0.2–1.5
Stranded with ferrule without plastic sleeve in mm20.25–1.5 0.25–1.5 0.25–1.5 0.25–1.5
Stranded with ferrule with plastic sleeve in mm20.5–1.0 0.5–2.5 0.5–1.5 0.5–2.5
Stripping length in Inches (mm) 0.31 (8) 0.31 (8) 0.31 (8) 0.31 (8)
Thread M3 M3 M3 M3
Torque in in-lb (Nm) 5.3–7.1 (0.6–0.8) 4.4–5.3 (0.5–0.6) 5.3–7.1 (0.6–0.8) 5.3–7.1 (0.6–0.8)
Catalog
Number Width Length
Cover
Length
Height for—
15 in
XBMUK25 0.20 (5.2) 1.10 (28.0) 0.04 (1.0) 1.26 (32.0)
XBMUK4 0.24 (6.2) 1.10 (28.0) 0.04 (1.0) 1.26 (32.0)
XBMUK25PE 0.20 (5.2) 1.10 (28.0) 1.24 (31.5)
XBMUK4PE 0.24 (6.2) 1.10 (28.0) 1.26 (32.0)
Volume 7—Logic Control, Operator Interface and Connectivity Solutions CA08100008E—November 2011 www.eaton.com V7-T8-31
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8.1
Terminal Blocks, Fuse Blocks and Fuse Holders
IEC—XB Series
Spring Cage Connection
Contents
Description Page
Spring Cage Terminal Blocks
Single Level—Through-Feed . . . . . . . . . . . . . . . V7-T8-32
Single Level—Ground Blocks . . . . . . . . . . . . . . V7-T8-37
Multi-Conductor Terminal Blocks . . . . . . . . . . . V7-T8-39
Multi-Conductor Ground Blocks . . . . . . . . . . . . V7-T8-42
Double Level Blocks . . . . . . . . . . . . . . . . . . . . . V7-T8-44
Triple Level Blocks . . . . . . . . . . . . . . . . . . . . . . V7-T8-46
Fuse Terminal Blocks . . . . . . . . . . . . . . . . . . . . V7-T8-48
Disconnect and Component Terminal Blocks . . V7-T8-51
Hybrid Terminal Blocks . . . . . . . . . . . . . . . . . . . V7-T8-54
Mini Spring Cage. . . . . . . . . . . . . . . . . . . . . . . . V7-T8-56
Drawings
Online
Spring Cage Terminal Blocks Overview
Product Description
The XBPT Series incorporates
a spring cage connection
system proven in applications
that are sensitive to vibration.
The spring mechanism
always exerts the same
constant force on the wire,
resulting in a vibration-
proof, gas-tight connection,
independent of the user.
The space-saving front
connection, with the wire
and screwdriver coming in
parallel from the same
direction, allows for simple
wiring in places where there
is little space available.
Application Description
The connection point is
opened with a standard
screwdriver. After the wire
has been inserted into the
wire guide of the terminal
block, the screwdriver is
removed and the wire
automatically makes contact.
Features
Vibration-resistance
Global acceptance
Multi-conductor
connections
Flexible Plug-in bridge
system
Large surface area for
marking
Standardized testing
system
Standards and Certifications
UL recognized—File No.
E67464
CE approved
LVD 1:
EN 60947-7-1
EN 60947-7-2
EN 60998-2-3
EN 60352-4/A1
ATEX approval
(Eex e applications)
Note
1Not all standards apply to all terminal
blocks. Contact Eaton for details.
V7-T8-32 Volume 7—Logic Control, Operator Interface and Connectivity Solutions CA08100008E—November 2011 www.eaton.com
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8.1
Terminal Blocks, Fuse Blocks and Fuse Holders
IECXB Series
Single Level—Through-Feed
Contents
Description Page
Single Level—Through-Feed
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . V7-T8-34
Technical Data and Specifications . . . . . . . . . . V7-T8-36
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . V7-T8-36
Single Level—Ground Blocks . . . . . . . . . . . . . . . . V7-T8-37
Multi-Conductor Terminal Blocks . . . . . . . . . . . . . V7-T8-39
Multi-Conductor Ground Blocks . . . . . . . . . . . . . . V7-T8-42
Double Level Blocks . . . . . . . . . . . . . . . . . . . . . . . V7-T8-44
Triple Level Blocks . . . . . . . . . . . . . . . . . . . . . . . . . V7-T8-46
Fuse Terminal Blocks . . . . . . . . . . . . . . . . . . . . . . . V7-T8-48
Disconnect and Component Terminal Blocks . . . . V7-T8-51
Hybrid Terminal Blocks . . . . . . . . . . . . . . . . . . . . . V7-T8-54
Mini Spring Cage . . . . . . . . . . . . . . . . . . . . . . . . . . V7-T8-56
Single Level—Through-Feed
Product Description
The space-saving design and
front entry design make the
XBPT Series ideal for control
systems where there is little
space. Even so, they offer
maximum connection
space, resulting in fast
wiring of stranded and
solid conductors with or
without ferrules.
XBPT terminal blocks are
available with cross-sections
from 2.5 mm2 up to 35 mm2.
The double bridge shaft can
accommodate individual
chain bridging and step-
down bridging from other
terminal blocks.
Volume 7—Logic Control, Operator Interface and Connectivity Solutions CA08100008E—November 2011 www.eaton.com V7-T8-33
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8.1
Terminal Blocks, Fuse Blocks and Fuse Holders
IEC—XB Series
Product Selection
Spring Cage Connection Single Level—Through-Feed
Note
1 EU type—examination certificate number: KEMA 05ATEX2158 U.
Terminal
Width
Maximum
Wire Size
IEC 60 947-7-1
in V/A/AWG
EN 50 019 1
in V/A/AWG
UL-cUL Ratings
in V/A/AWG Color
Standard
Pack
Catalog
Number
5.2 mm 12 AWG/2.5 mm2800/31/28–12 550/25/21/24–12 600/20/26–12 Gray 50 XBPT25
Blue 50 XBPT25BU
White 50 XBPT25WH
Red 50 XBPT25RD
Black 50 XBPT25BK
6.2 mm 10 AWG/4 mm2800/40/28–10 550/34/30/24–10 600/30/20–10 Gray 50 XBPT4
Blue 50 XBPT4BU
8.2 mm 8 AWG/6 mm2800/52/24–8 550/45/36/20–8 600/50/20–8 Gray 50 XBPT6
Blue 50 XBPT6BU
10.2 mm 6 AWG/10 mm2800/65/24–6 550/50/63/16–6 600/65/16–6 Gray 50 XBPT10
Blue 50 XBPT10BU
12 mm 4 AWG/16 mm2800/90/24–4 550/65/82/16–4 600/50/16–4 Gray 50 XBPT16
Blue 50 XBPT16BU
16 mm 2 AWG/35 mm2800/125/14–2 750/108/14–2 600/115/14–2 Gray 50 XBPT35
Blue 50 XBPT35BU
XBPT6
V7-T8-34 Volume 7—Logic Control, Operator Interface and Connectivity Solutions CA08100008E—November 2011 www.eaton.com
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8.1
Terminal Blocks, Fuse Blocks and Fuse Holders
IECXB Series
Accessories
Spring Cage Connection Single Level—Through-Feed, XBPT25, XBPT4 an d XBPT6
Spring Cage Connection Single Level—Through-Feed, XBPT10, XBPT16 and XBPT35
Notes
1For ordering information, see Page V7-T8-105.
2For information on Printed Marking Tag Options, see Page V7-T8-98.
3XBPT35 has an enclosed design. The use of an end cover is not required.
For additional accessories, see Page V7-T8-90.
XBPT25 XBPT4 XBPT6
Description Color
Number of
Positions
Standard
Pack
Catalog
Number
Catalog
Number
Catalog
Number
End cover Gray 10 XBACPT25 XBACPT4 XBACPT6
Partition plate Gray 10 XBATPT4 XBATPT4 XBATPT6
Plug-in bridge—for cross connections
in the bridge shaft
Red 2 10 XBAFBS25 XBAFBS26 XBAFBS28
310XBAFBS35 XBAFBS36
510XBAFBS55 XBAFBS56
10 10 XBAFBS105 XBAFBS106
50 10 XBAFBS505 XBAFBS506
Test adapter 10 XBATSPAI4 XBATSPAI4 XBATSPAI4
2.3 mm diameter test plug XBATSMPS-_ 1XBATSMPS-_ 1XBATSMPS-_ 1
Modular test plug 10 XBATSPS5 XBATSPS6 XBATSPS8
Blank marker strip external labeling White 10 XBMZBF5 2XBMZBF6 2XBMZF8 2
Blank marker strip center labeling (strip of 10) White 10 XBMZB5 2XBMZB6 2XBMZB8 2
Description Color
Number of
Positions
Standard
Pack
XBPT10 XBPT16 XBPT35
Catalog
Number
Catalog
Number
Catalog
Number
End cover Gray 10 XBACPT10 XBACPT16 3
Plug-in bridge—for cross connections in
the bridge shaft
Red 2 10 XBAFBS210 XBAFBS212 1XBAFBS216 2
2.3 mm diameter test plug 10 XBATSMPS-_ 1XBATSMPS-_ 1XBATSMPS-_ 1
Blank marker strip external labeling White 10 XBMZF10 2XBMZBF12 2XBMZBF15 2
Blank marker strip center labeling (strip of 10) White 10 XBMZB10 2XBMZB12 2XBMZB15 2
Volume 7—Logic Control, Operator Interface and Connectivity Solutions CA08100008E—November 2011 www.eaton.com V7-T8-35
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8.1
Terminal Blocks, Fuse Blocks and Fuse Holders
IEC—XB Series
XBPT with Reducing Bridge
Step-Down Bridge with Standard Feed-Through Terminal Blocks
Input Pick-Off One-Sided
Input
Imax
Central
Input
Imax
Bridge
Terminal
Blocks Cross-Section
Terminal
Blocks
Cross-Section
AWG (mm2)
Catalog
Number
XBPT6 8 AWG (6 mm2) XBPT25 12 (2.5) 40 56 XBARBST6
XBPT4 10 (4) 45 56 XBARBST6
XBQT15 14 (1.5) 35 56 XBARBST6
XBQT25 12 (2.5) 40 56 XBARBST6
XBPT10 6 AWG (10 mm2) XBPT25 12 (2.5) 40 65 XBARBST10
XBPT4 10 (4) 45 65 XBARBST10
XBQT15 14 (1.5) 35 65 XBARBST10
XBQT25 12 (2.5) 40 65 XBARBST10
XBPT16 4 AWG (16 mm2) XBPT25 12 (2.5) 40 80 XBARBST16
XBPT4 10 (4) 45 90 XBARBST16
XBQT15 14 (1.5) 35 70 XBARBST16
XBQT25 12 (2.5) 40 80 XBARBST16
lmax
One-Sided Input Central Input
lmax
XBACPT6
XBARBST6
XBPT25XBPT25
XBPT6
XBACPT25
V7-T8-36 Volume 7—Logic Control, Operator Interface and Connectivity Solutions CA08100008E—November 2011 www.eaton.com
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8.1
Terminal Blocks, Fuse Blocks and Fuse Holders
IECXB Series
Technical Data and Specifications
Spring Cage Connection Single Level—Through-Feed
Dimensions
Approximate Dimensions in Inches (mm)
Spring Cage Connection Single Level—Through-Feed
Note
1XBPT35 has an enclosed design. The use of an end cover is not required.
Description XBPT25 XBPT4 XBPT6 XBPT10 XBPT16 XBPT35
Technical Data in Accordance with IEC
Maximum load current in A/cross-section in mm231/4 40/6 52/10 65/16 90/25 125/35
Rated surge voltage in kV/contamination class 8/3 8/3 8/3 8/3 8/3 8/3
Surge voltage category/insulating material group III/I III/I III/I III/I III/I III/I
Connection Capacity
Stranded with ferrule/with ferrule and
plastic sleeve in mm2
0.25–2.5 0.25–4 0.25–6 0.25–10 0.25–16 2.5–35
Stranded with ferrules without plastic sleeve in mm20.25–2.5 0.25–4 0.25–6 0.25–10 0.25–16 2.5–35
Stranded with twin ferrule with plastic sleeve in mm20.5 0.5–1 0.5–1.5 1.5–2.5 1.5–4 2.5–10
Stripping length in inches (mm) 0.39 (10) 0.39 (10) 0.47 (12) 0.71 (18) 0.71 (18) 0.98 (25)
Catalog
Number Width Length
Cover
Width
Height for—
35 x 7.5 in 35 x 15 in
XBPT25 0.20 (5.2) 1.91 (48.5) 0.09 (2.2) 1.45 (36.8) 1.73 (44.0)
XBPT4 0.24 (6.2) 2.20 (56.0) 0.09 (2.2) 1.45 (36.8) 1.73 (44.0)
XBPT6 0.32 (8.2) 2.74 (69.5) 0.09 (2.2) 1.71 (43.5) 2.01 (51.0)
XBPT10 0.39 (10.0) 2.81 (71.5) 0.09 (2.2) 1.99 (50.5) 2.30 (58.5)
XBPT16 0.47 (12.0) 3.15 (80.0) 0.09 (2.2) 2.01 (51.0) 2.30 (58.5)
XBPT35 0.63 (16.0) 3.94 (100.0) 12.32 (59.0) 2.62 (66.5)
Volume 7—Logic Control, Operator Interface and Connectivity Solutions CA08100008E—November 2011 www.eaton.com V7-T8-37
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8.1
Terminal Blocks, Fuse Blocks and Fuse Holders
IEC—XB Series
Single Level—Ground Blocks
Contents
Description Page
Single Level—Through-Feed . . . . . . . . . . . . . . . . . V7-T8-32
Single Level—Ground Blocks
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . V7-T8-38
Technical Data and Specifications . . . . . . . . . . V7-T8-38
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . V7-T8-38
Multi-Conductor Terminal Blocks . . . . . . . . . . . . . . V7-T8-39
Multi-Conductor Ground Blocks . . . . . . . . . . . . . . V7-T8-42
Double Level Blocks . . . . . . . . . . . . . . . . . . . . . . . V7-T8-44
Triple Level Blocks . . . . . . . . . . . . . . . . . . . . . . . . . V7-T8-46
Fuse Terminal Blocks . . . . . . . . . . . . . . . . . . . . . . . V7-T8-48
Disconnect and Component Terminal Blocks . . . . V7-T8-51
Hybrid Terminal Blocks . . . . . . . . . . . . . . . . . . . . . V7-T8-54
Mini Spring Cage . . . . . . . . . . . . . . . . . . . . . . . . . . V7-T8-56
Single Level—Ground Blocks
Product Description
The XBPT ground blocks are
the same shape as the feed-
through terminal blocks with
the same wide range of
cross-sections available.
They easily snap onto the
DIN rail to make a reliable
mechanical and electrical
contact that meets all
requirements of
IEC 60-947-7-2.
Product Selection
Spring Cage Connection Single Level—Ground Blocks
Notes
1 EU type—examination certificate number: KEMA 05ATEX2154 U (XBPT25PE), KEMA 05ATEX2155 U (XBPT4PE).
2 EU type—examination certificate number: KEMA 05ATEX2156 U.
Terminal
Width
Maximum
Wire Size
IEC 60 947-7-2
in V/A/AWG
EN 50 019 1
in V/A/AWG
UL-cUL Ratings
in V/A/AWG Color
Standard
Pack
Catalog
Number
5.2 mm 12 AWG/2.5 mm2—/—/28–12 —/—/24–12 —/—/26–12 Green/Yellow 50 XBPT25PE
6.2 mm 10 AWG/4 mm2—/—/28–10 —/—/24–10 —/—/20–10 Green/Yellow 50 XBPT4PE
8.2 mm 8 AWG/6 mm2—/—/24–8 —/—/20–8 —/—/20–8 Green/Yellow 50 XBPT6PE
10.2 mm 6 AWG/10 mm2—/65/24–6 —/—/16–6 —/—/16–6 Green/Yellow 50 XBPT10PE
12 mm 4 AWG/16 mm2—/90/24–4 —/—/16–4 2—/—/16–4 Green/Yellow 25 XBPT16PE
16 mm 2 AWG/35 mm2—/125/14–2 —/—/14–2 2—/—/14–2 Green/Yellow 10 XBPT35PE
XBPT4PE
V7-T8-38 Volume 7—Logic Control, Operator Interface and Connectivity Solutions CA08100008E—November 2011 www.eaton.com
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8.1
Terminal Blocks, Fuse Blocks and Fuse Holders
IECXB Series
Accessories
Spring Cage Connection Single Level Ground Blocks, XBPT25PE, XBPT4PE and XBPT6PE
Spring Cage Connection Single Level Ground Blocks, XBPT10PE, XBPT16PE and XBPT35PE
Technical Data and Specifications
Spring Cage Connection Single Level Ground Blocks
Dimensions
Approximate Dimensions in Inches (mm)
Spring Cage Connection Single Level Ground Blocks
Notes
1For information on Printed Marking Tag Options, see Page V7-T8-98.
2XBPT35PE has an enclosed design. The use of an end cover is not required.
For additional accessories, see Page V7-T8-90.
Description Color
Number of
Positions
Standard
Pack
XBPT25PE XBPT4PE XBPT6PE
Catalog
Number
Catalog
Number
Catalog
Number
End cover Gray 10 XBACPT25 XBACPT4 XBACPT6
Blank marker strip external labeling White 10 XBMZBF5 1XBMZBF6 1XBMZBF8 1
Blank marker strip center labeling (strip of 10) White 10 XBMZB5 1XBMZB6 1XBMZB8 1
Description Color
Number of
Positions
Standard
Pack
XBPT10PE XBPT16PE XBPT35PE
Catalog
Number
Catalog
Number
Catalog
Number
End cover Gray 10 XBACPT10 XBACPT16 2
Plug-in bridge—for cross connections in
the bridge shaft
—2 10XBAFBS210 XBAFBS212 XBAFBS216
Blank marker strip external labeling White 10 XBMZBF10 1XBMZBF12 1XBMZBF15 1
Blank marker strip center labeling (strip of 10) White 10 XBMZB10 1XBMZB12 1XBMZB15 1
Description XBPT25PE XBPT4PE XBPT6PE XBPT10PE XBPT16PE XBPT35PE
Technical Data in Accordance with IEC
Maximum load current in A/cross-section in mm2———65/1690/25125/35
Rated surge voltage in kV/contamination class 8/3 8/3 8/3 8/3 8/3 8/3
Surge voltage category/insulating material group III/I III/I III/I III/I III/I III/I
Connection Capacity
Stranded with ferrule with plastic sleeve in mm20.25–2.5 0.25–4 0.25–6 0.25–10 0.25–16 2.5–35
Stranded with ferrules without plastic sleeve in mm20.25–2.5 0.25–4 0.25–6 0.25–10 0.25–16 2.5–35
Stranded with twin ferrule with plastic sleeve in mm20.5 0.5–1 0.5–1.5 1.5–2.5 1.5–4 2.5–10
Stripping length in inches (mm) 0.39 (10) 0.39 (10) 0.47 (12) 0.71 (18) 0.71 (18) 0.98 (25)
Catalog
Number Width Length
Cover
Width
Height for—
35 x 7.5 in 35 x 15 in
XBPT25PE 0.20 (5.2) 1.91 (48.5) 0.09 (2.2) 1.45 (36.8) 1.73 (44.0)
XBPT4PE 0.24 (6.2) 2.20 (56.0) 0.09 (2.2) 1.45 (36.8) 1.73 (44.0)
XBPT6PE 0.32 (8.2) 2.74 (69.5) 0.09 (2.2) 1.71 (43.5) 2.01 (51.0)
XBPT10PE 0.39 (10.0) 2.81 (71.5) 0.09 (2.2) 1.99 (50.5) 2.28 (58.0)
XBPT16PE 0.47 (12.0) 3.15 (80.0) 0.09 (2.2) 2.01 (51.0) 2.30 (58.5)
XBPT35PE 0.63 (16.0) 3.94 (100.0) 2.32 (59.0) 2.62 (66.5)
Volume 7—Logic Control, Operator Interface and Connectivity Solutions CA08100008E—November 2011 www.eaton.com V7-T8-39
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8.1
Terminal Blocks, Fuse Blocks and Fuse Holders
IEC—XB Series
Multi-Conductor Terminal Blocks
Contents
Description Page
Single Level—Through-Feed . . . . . . . . . . . . . . . . . V7-T8-32
Single Level—Ground Blocks . . . . . . . . . . . . . . . . . V7-T8-37
Multi-Conductor Terminal Blocks
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . V7-T8-40
Technical Data and Specifications . . . . . . . . . . V7-T8-41
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . V7-T8-41
Multi-Conductor Ground Blocks . . . . . . . . . . . . . . V7-T8-42
Double Level Blocks . . . . . . . . . . . . . . . . . . . . . . . V7-T8-44
Triple Level Blocks . . . . . . . . . . . . . . . . . . . . . . . . . V7-T8-46
Fuse Terminal Blocks . . . . . . . . . . . . . . . . . . . . . . . V7-T8-48
Disconnect and Component Terminal Blocks . . . . V7-T8-51
Hybrid Terminal Blocks . . . . . . . . . . . . . . . . . . . . . V7-T8-54
Mini Spring Cage . . . . . . . . . . . . . . . . . . . . . . . . . . V7-T8-56
Multi-Conductor Terminal Blocks
Product Description
The multi-conductor terminal
blocks offer a space-saving
alternative to standard feed-
through terminal blocks,
allowing for high-density
wiring. Often, three
connections have to be led
to one terminal block. The
XBPT…D12 terminal block
accomplishes this without
any additional terminal blocks
or bridging required. The
XBPT…D22 terminal blocks
allow four wires to be
connected to one potential—
and can therefore be used as
compact power distributors.
There is also a version,
XBPT25D22U or XBPT4D22U,
with an interrupted bus bar in
the terminal center. This
makes two feed-through
terminal blocks available in
one level. One side of this
block can be bridged using
the standard Plug-in bridges.
Double marker carriers are
available for clear marking of
the feed-through levels.
Product Selection
Spring Cage Connection Multi-Conductor Terminal Blocks, Three-Wire
Note
1 EU type—examination certificate number: KEMA 05ATEX2154 U (XBPT25D12), KEMA 05ATEX2155 U (XBPT4D12).
Terminal
Width
Maximum
Wire Size
IEC 60 947-7-1
in V/A/AWG
EN 50 019 1
in V/A/AWG
UL-cUL Ratings
in V/A/AWG Color
Standard
Pack
Catalog
Number
5.2 mm 12 AWG/2.5 mm2800/28/28–12 550/25/21/24–12 600/20/26–12 Gray 50 XBPT25D12
Blue 50 XBPT25D12BU
6.2 mm 10 AWG/4 mm2800/40/28–10 550/34/29/24–10 600/30/20–10 Gray 50 XBPT4D12
Blue 50 XBPT4D12BU
XBPT4D12
V7-T8-40 Volume 7—Logic Control, Operator Interface and Connectivity Solutions CA08100008E—November 2011 www.eaton.com
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8.1
Terminal Blocks, Fuse Blocks and Fuse Holders
IECXB Series
Spring Cage Connection Multi-Conductor Terminal Blocks, Four-Wire
Accessories
Spring Cage Connection Multi-Conductor Terminal Blocks
Notes
1EU type—examination certificate number: KEMA 05ATEX2154 U (XBPT25D22), KEMA 05ATEX2155 (XBPT4D22).
2For ordering information, see Page V7-T8-105.
3For information on Printed Marking Tag Options, see Page V7-T8-98.
For additional accessories, see Page V7-T8-90.
Terminal
Width
Maximum
Wire Size
IEC 60 947-7-1
in V/A/AWG
EN 50 019 1
in V/A/AWG
UL-cUL Ratings
in V/A/AWG Color
Standard
Pack
Catalog
Number
Spring Cage Multi-Conductor
5.2 mm 12 AWG/2.5 mm2800/28/28–12 550/24/21/24–12 600/20/26–12 Gray 50 XBPT25D22
Blue 50 XBPT25D22BU
6.2 mm 10 AWG/4 mm2800/40/28–10 550/34/25/24–10 600/30/20–10 Gray 50 XBPT4D22
Blue 50 XBPT4D22BU
Spring Cage Multi-Conductor with Interrupted Bus Bar
5.2 mm 12 AWG/2.5 mm2800/28/28–12 550/24/21/24–12 600/20/26–12 Blue 50 XBPT25D22U
6.2 mm 10 AWG/4 mm2800/40/28–10 550/34/25/24–10 600/30/20–10 Blue 50 XBPT4D22U
Description Color
Number of
Positions
Standard
Pack
XBPT25D12 XBPT4D12 XBPT25D22 XBPT4D22
Catalog
Number
Catalog
Number
Catalog
Number
Catalog
Number
End cover Gray 10 XBACPT25D12 XBACPT4D12 XBACPT25D22 XBACPT4D22
End cover segment Gray 10 XBASPT25 XBASPT4 XBASPT25 XBASPT4
Partition plate 10 XBATPTD12 XBATPTD12 XBATPTD22 XBATPTD22
Plug-in bridge—for cross connections in
the bridge shaft
Red 2 10 XBAFBS25 XBAFBS26 XBAFBS25 XBAFBS26
310XBAFBS35 XBAFBS36 XBAFBS35 XBAFBS36
510XBAFBS55 XBAFBS56 XBAFBS55 XBAFBS56
10 10 XBAFBS105 XBAFBS106 XBAFBS105 XBAFBS106
50 10 XBAFBS505 XBAFBS506 XBAFBS505 XBAFBS506
Test adapter 10 XBATSPAI4 XBATSPAI4 XBATSPAI4 XBATSPAI4
2.3 mm diameter test plug XBATSMPS-_ 2XBATSMPS-_ 2XBATSMPS-_ 2XBATSMPS-_ 2
Modular test plug 10 XBATSPS5 XBATSPS6 XBATSPS5 XBATSPS6
Blank marker strip external labeling White 10 XBMZBF5 3XBMZBF6 3XBMZBF5 3XBMZBF6 3
Blank marker strip center labeling (strip of 10) White 10 XBMZB5 3XBMZB6 3XBMZB5 3XBMZB6 3
XBPT25D22
Volume 7—Logic Control, Operator Interface and Connectivity Solutions CA08100008E—November 2011 www.eaton.com V7-T8-41
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8.1
Terminal Blocks, Fuse Blocks and Fuse Holders
IEC—XB Series
Technical Data and Specifications
Spring Cage Connection Multi-Conductor Terminal Blocks
Dimensions
Approximate Dimensions in Inches (mm)
Spring Cage Connection Multi-Conductor Terminal Blocks
Description XBPT25D12 XBPT4D12 XBPT25D22 XBPT4D22
Technical Data in Accordance with IEC
Maximum load current in A/cross-section in mm228/4 40/6 28/4 40/6
Rated surge voltage in kV/contamination class 8/3 8/3 8/3 8/3
Surge voltage category/insulating material group III/I III/I III/I III/I
Connection Capacity
Stranded with ferrule with plastic sleeve in mm20.25–2.5 0.25–4 0.25–2.5 0.25–4
Stranded with ferrules without plastic sleeve in mm20.25–2.5 0.25–4 0.25–2.5 0.25–4
Stranded with twin ferrule with plastic sleeve in mm20.5 0.5–1 0.5 0.5–1
Stripping length in inches (mm) 0.39 (10) 0.39 (10) 0.39 (10) 0.39 (10)
Catalog
Number Width Length
Cover
Width
Height for—
35 x 7.5 in 35 x 15 in
XBPT25D12 0.20 (5.2) 2.38 (60.5) 0.09 (2.2) 1.44 (36.5) 1.73 (44.0)
XBPT4D12 0.24 (6.2) 2.81 (71.5) 0.09 (2.2) 1.44 (36.5) 1.73 (44.0)
XBPT25D22 0.20 (5.2) 2.83 (72.0) 0.09 (2.2) 1.44 (36.5) 1.73 (44.0)
XBPT4D22 0.24 (6.2) 3.43 (87.0) 0.09 (2.2) 1.44 (36.5) 1.73 (44.0)
V7-T8-42 Volume 7—Logic Control, Operator Interface and Connectivity Solutions CA08100008E—November 2011 www.eaton.com
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8.1
Terminal Blocks, Fuse Blocks and Fuse Holders
IECXB Series
Multi-Conductor Terminal Blocks
Contents
Description Page
Single Level—Through-Feed . . . . . . . . . . . . . . . . . V7-T8-32
Single Level—Ground Blocks . . . . . . . . . . . . . . . . . V7-T8-37
Multi-Conductor Terminal Blocks . . . . . . . . . . . . . V7-T8-39
Multi-Conductor Ground Blocks
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . V7-T8-43
Technical Data and Specifications . . . . . . . . . . V7-T8-43
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . V7-T8-43
Double Level Blocks . . . . . . . . . . . . . . . . . . . . . . . V7-T8-44
Triple Level Blocks . . . . . . . . . . . . . . . . . . . . . . . . . V7-T8-46
Fuse Terminal Blocks . . . . . . . . . . . . . . . . . . . . . . . V7-T8-48
Disconnect and Component Terminal Blocks . . . . V7-T8-51
Hybrid Terminal Blocks . . . . . . . . . . . . . . . . . . . . . V7-T8-54
Mini Spring Cage . . . . . . . . . . . . . . . . . . . . . . . . . . V7-T8-56
Multi-Conductor Ground Blocks
Product Description
The ground terminal blocks
have the same shape and
pitch as the standard terminal
block, in a green-yellow
housing. They easily snap
onto the DIN rail to make
a reliable mechanical and
electrical contact that
meets all requirements
of IEC 60-947-7-2.
Product Selection
Spring Cage Connection Multi-Conductor Ground Blocks, Three-Wire
Spring Cage Connection Multi-Conductor Ground Blocks, Four-Wire
Note
1 EU type—examination certificate number: KEMA 05ATEX2154 U (XBPT25D12PE), KEMA 05ATEX2155 U (XBPT4D12PE).
Terminal
Width
Maximum
Wire Size
IEC 60 947-7-2
in V/A/AWG
EN 50 019 1
in V/A/AWG
UL-cUL Ratings
in V/A/AWG Color
Standard
Pack
Catalog
Number
5.2 mm 12 AWG/2.5 mm2—/—/28–12 —/—/24–12 —/—/26–12 Green/Yellow 50 XBPT25D12PE
6.2 mm 10 AWG/4 mm2—/—/28–10 —/—/24–10 —/—/20–10 Green/Yellow 50 XBPT4D12PE
Terminal
Width
Maximum
Wire Size
IEC 60 947-7-2
in V/A/AWG
EN 50 019 1
in V/A/AWG
UL-cUL Ratings
in V/A/AWG Color
Standard
Pack
Catalog
Number
5.2 mm 12 AWG/2.5 mm2—/—/28–12 —/—/24–12 —/—/26–12 Green/Yellow 50 XBPT25D22PE
6.2 mm 10 AWG/4 mm2—/—/28–10 —/—/24–10 —/—/20–10 Green/Yellow 50 XBPT4D22PE
XBPT25D12PE
XBPT4D22PE
Volume 7—Logic Control, Operator Interface and Connectivity Solutions CA08100008E—November 2011 www.eaton.com V7-T8-43
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8.1
Terminal Blocks, Fuse Blocks and Fuse Holders
IEC—XB Series
Accessories
Spring Cage Connection Multi-Conductor Ground Blocks
Technical Data and Specifications
Spring Cage Connection Multi-Conductor Ground Blocks
Dimensions
Approximate Dimensions in Inches (mm)
Spring Cage Connection Multi-Conductor Ground Blocks
Notes
1For information on Printed Marking Tag Options, see Page V7-T8-98.
For additional accessories, see Page V7-T8-90.
Description Color
Number of
Positions
Standard
Pack
XBPT25D12PE XBPT4D12PE XBPT25D22PE XBPT4D22PE
Catalog
Number
Catalog
Number
Catalog
Number
Catalog
Number
End cover Gray 10 XBACPT25D12 XBACPT4D12 XBACPT25D22 XBACPT4D22
End cover segment Gray 10 XBASPT25 XBASPT4 XBASPT25 XBASPT4
Blank marker strip external labeling White 10 XBMZBF5 1XBMZBF6 1XBMZBF5 1XBMZBF6 1
Blank marker strip center
labeling (strip of 10)
White 10 XBMZB5 1XBMZB6 1XBMZB5 1XBMZB6 1
Description XBPT25D12PE XBPT4D12PE XBPT25D22PE XBPT4D22PE
Technical Data in Accordance with IEC
Maximum load current in A/cross-section in mm2————
Rated surge voltage in kV/contamination class 8/3 8/3 8/3 8/3
Surge voltage category/insulating material group III/I III/I III/I III/I
Connection Capacity
Stranded with ferrule with plastic sleeve in mm20.25–2.5 0.25–4 0.25–2.5 0.25–4
Stranded with ferrules without plastic sleeve in mm20.25–2.5 0.25–4 0.25–2.5 0.25–4
Stranded with twin ferrule with plastic sleeve in mm20.5 0.5–1 0.5 0.5–1
Stripping length in inches (mm) 0.39 (10) 0.39 (10) 0.39 (10) 0.39 (10)
Catalog
Number Width Length
Cover
Width
Height for—
35 x 7.5 in 35 x 15 in
XBPT25D12PE 0.20 (5.2) 2.38 (60.5) 0.09 (2.2) 1.44 (36.5) 1.73 (44.0)
XBPT4D12PE 0.24 (6.2) 2.81 (71.5) 0.09 (2.2) 1.44 (36.5) 1.73 (44.0)
XBPT25D22PE 0.20 (5.2) 2.83 (72.0) 0.09 (2.2) 1.44 (36.5) 1.73 (44.0)
XBPT4D22PE 0.24 (6.2) 3.43 (87.0) 0.09 (2.2) 1.44 (36.5) 1.73 (44.0)
V7-T8-44 Volume 7—Logic Control, Operator Interface and Connectivity Solutions CA08100008E—November 2011 www.eaton.com
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8.1
Terminal Blocks, Fuse Blocks and Fuse Holders
IECXB Series
Double Level Blocks
Contents
Description Page
Single Level—Through-Feed . . . . . . . . . . . . . . . . . V7-T8-32
Single Level—Ground Blocks . . . . . . . . . . . . . . . . . V7-T8-37
Multi-Conductor Terminal Blocks . . . . . . . . . . . . . V7-T8-39
Multi-Conductor Ground Blocks . . . . . . . . . . . . . . V7-T8-42
Double Level Blocks
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . V7-T8-45
Technical Data and Specifications . . . . . . . . . . V7-T8-45
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . V7-T8-45
Triple Level Blocks . . . . . . . . . . . . . . . . . . . . . . . . . V7-T8-46
Fuse Terminal Blocks . . . . . . . . . . . . . . . . . . . . . . . V7-T8-48
Disconnect and Component Terminal Blocks . . . . V7-T8-51
Hybrid Terminal Blocks . . . . . . . . . . . . . . . . . . . . . V7-T8-54
Mini Spring Cage . . . . . . . . . . . . . . . . . . . . . . . . . . V7-T8-56
Double Level Blocks
Product Description
The potentials of the XB
double level terminal blocks
routed on two levels reduce
space requirements by 50%
compared with single level
terminal blocks.
The XBPTT blocks can be
bridged on both levels with
the Plug-in bridge system and
labeling options are available
for each terminal point,
resulting in maximum
customization for each
application. The XBPTT25PV
and XBPTT4PV terminal
blocks have two
interconnected levels.
Equipotential bonding is
marked by an imprint on
the housing. These terminal
blocks can also be bridged and
used to construct compact
potential distributor blocks.
Product Selection
Spring Cage Connection Double Level Blocks
Spring Cage Connection Double Level Ground Blocks
Note
1 EU type—examination certificate number: KEMA 05ATEX2154 U (XBPTT25), KEMA 05ATEX2155 U (XBPTT4).
Terminal
Width
Maximum
Wire Size
IEC 60 947-7-1
in V/A/AWG
EN 50 019 1
in V/A/AWG
UL-cUL Ratings
in V/A/AWG Color
Standard
Pack
Catalog
Number
Spring Cage Connection Double Level Blocks
5.2 mm 12 AWG/2.5 mm2500/26/28–12 420/23/19/24–12 600/20/26–12 Gray 50 XBPTT25
Blue 50 XBPTT25BU
6.2 mm 10 AWG/4 mm2500/32/28–10 420/32/27/24–10 300/30/20–10 Gray 50 XBPTT4
Blue 50 XBPTT4BU
Spring Cage Connection Double Level Blocks (terminal block with potential distribution between the levels)
5.2 mm 112 AWG/2.5 mm2500/26/28–12 420/23/19/24–12 600/20/26–12 Gray 50 XBPTT25PV
6.2 mm 10 AWG/4 mm2500/32/28–10 420/32/27/24–10 300/30/20–10 Gray 50 XBPTT4PV
Terminal
Width
Maximum
Wire Size
IEC 60 947-7-2
in V/A/AWG
EN 50 019 1
in V/A/AWG
UL-cUL Ratings
in V/A/AWG Color
Standard
Pack
Catalog
Number
5.2 mm 12 AWG/2.5 mm2—/—/28–12 —/—/24–12 —/—/26–12 Green/Yellow 50 XBPTT25PE
6.2 mm 10 AWG/4 mm2—/—/28–10 —/—/24–10 —/—/20–10 Green/Yellow 50 XBPTT4PE
XBPTT4
XBPTT25PE
Volume 7—Logic Control, Operator Interface and Connectivity Solutions CA08100008E—November 2011 www.eaton.com V7-T8-45
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8.1
Terminal Blocks, Fuse Blocks and Fuse Holders
IEC—XB Series
Accessories
Spring Cage Connection Double Level Blocks
Technical Data and Specifications
Spring Cage Connection Double Level Blocks
Dimensions
Approximate Dimensions in Inches (mm)
Spring Cage Connection Double Level Blocks
Notes
1For information on Printed Marking Tag Options, see Page V7-T8-98.
For additional accessories, see Page V7-T8-90.
Description Color
Number of
Positions
Standard
Pack
XBPTT25 XBPTT4 XBPTT25PE XBPTT4PE
Catalog
Number
Catalog
Number
Catalog
Number
Catalog
Number
End cover Gray 10 XBACPTT25 XBACPTT4 XBACPTT25 XBACPTT4
Partition plate 10/50 XBATPTT4 XBATPTT4
Plug-in bridge—for cross connections in
the bridge shaft
Red 2 10 XBAFBS25 XBAFBS26 XBAFBS25 XBAFBS26
310 XBAFBS35 XBAFBS36 XBAFBS35 XBAFBS36
510 XBAFBS55 XBAFBS56 XBAFBS55 XBAFBS56
10 10 XBAFBS105 XBAFBS106 XBAFBS105 XBAFBS106
50 10 XBAFBS505 XBAFBS506 XBAFBS505 XBAFBS506
Test adapter 10 XBATSPAI4 XBATSPAI4
Modular test plug 10 XBATSPS5 XBATSPS6
Blank marker strip (strip of 10) White 10 XBMZBF5 1XBMZBF6 1XBMZBF5 1XBMZBF6 1
Description XBPTT25 XBPTT4 XBPTT25PE XBPTT4PE
Technical Data in Accordance with IEC
Maximum load current in A/cross-section in mm226/4 32/6
Rated surge voltage in kV/contamination class 6/3 6/3 6/3 6/3
Surge voltage category/insulating material group III/I III/I III/I III/I
Connection Capacity
Stranded with ferrule with plastic sleeve in mm20.25–2.5 0.25–4 0.25–2.5 0.25–4
Stranded with ferrules without plastic sleeve in mm20.25–2.5 0.25–4 0.25–2.5 0.25–4
Stranded with twin ferrule with plastic sleeve in mm20.5 0.5–1 0.5 0.5–1
Stripping length in inches (mm) 0.39 (10) 0.39 (10) 0.39 (10) 0.39 (10)
Catalog
Number Width Length
Cover
Width
Height for—
35 x 7.5 in 35 x 15 in
XBPTT25 0.20 (5.2) 2.66 (67.5) 0.09 (2.2) 1.87 (47.5) 2.17 (55.0)
XBPTT4 0.24 (6.2) 3.29 (83.5) 0.09 (2.2) 1.87 (47.5) 2.17 (55.0)
XBPTT25PE 0.20 (5.2) 2.66 (67.5) 0.09 (2.2) 1.87 (47.5) 2.17 (55.0)
XBPTT4PE 0.24 (6.2) 3.29 (83.5) 0.09 (2.2) 1.87 (47.5) 2.17 (55.0)
V7-T8-46 Volume 7—Logic Control, Operator Interface and Connectivity Solutions CA08100008E—November 2011 www.eaton.com
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8.1
Terminal Blocks, Fuse Blocks and Fuse Holders
IECXB Series
Triple Level Blocks
Contents
Description Page
Single Level—Through-Feed . . . . . . . . . . . . . . . . . V7-T8-32
Single Level—Ground Blocks . . . . . . . . . . . . . . . . . V7-T8-37
Multi-Conductor Terminal Blocks . . . . . . . . . . . . . V7-T8-39
Multi-Conductor Ground Blocks . . . . . . . . . . . . . . V7-T8-42
Double Level Blocks . . . . . . . . . . . . . . . . . . . . . . . V7-T8-44
Triple Level Blocks
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . V7-T8-47
Technical Data and Specifications . . . . . . . . . . V7-T8-47
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . V7-T8-47
Fuse Terminal Blocks . . . . . . . . . . . . . . . . . . . . . . . V7-T8-48
Disconnect and Component Terminal Blocks . . . . V7-T8-51
Hybrid Terminal Blocks . . . . . . . . . . . . . . . . . . . . . V7-T8-54
Mini Spring Cage . . . . . . . . . . . . . . . . . . . . . . . . . . V7-T8-56
Triple Level Blocks
Product Description
The spring cage triple level
terminal block incorporates
three feed-through levels
in a 5.2 mm wide housing.
This is ideal for high density
wiring, especially important
when switchgear space is
restricted. There is a bridge
shaft on each level allowing
use of this block as a compact
potential distributor or as
a sensor terminal.
The XBPTK25PV has
all six terminal points
interconnected. All the
triple level blocks can be
labeled on each level.
Product Selection
Spring Cage Connection Triple Level Blocks
Note
1 Terminal block with potential distribution between the levels.
Terminal
Width
Maximum
Wire Size
IEC 60 947-7-1
in V/A/AWG
UL-cUL Ratings
in V/A/AWG Color
Standard
Pack
Catalog
Number
5.2 mm 12 AWG/2.5 mm2500/28/28–12 600/20/26–12 Gray 50 XBPTK25
5.2 mm 12 AWG/2.5 mm2500/28/28–12 600/20/26–12 Gray 50 XBPTK25PV 1
XBPTK25
Volume 7—Logic Control, Operator Interface and Connectivity Solutions CA08100008E—November 2011 www.eaton.com V7-T8-47
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8.1
Terminal Blocks, Fuse Blocks and Fuse Holders
IEC—XB Series
Accessories
Spring Cage Connection Triple Level Blocks
Technical Data and Specifications
Spring Cage Connection Triple Level Blocks
Dimensions
Approximate Dimensions in Inches (mm)
Spring Cage Connection Triple Level Blocks
Notes
1For information on Printed Marking Tag Options, see Page V7-T8-98.
For additional accessories, see Page V7-T8-90.
Description Color
Number of
Positions
Standard
Pack
XBPTK25 XBPTK25PV
Catalog
Number
Catalog
Number
End cover Gray 10 XBACPT25K XBACPT25K
Plug-in bridge—for cross connections in
the bridge shaft
Red 2 10 XBAFBS25 XBAFBS25
310 XBAFBS35 XBAFBS35
510 XBAFBS55 XBAFBS55
10 10 XBAFBS105 XBAFBS105
50 10 XBAFBS505 XBAFBS505
Test adapter 10 XBATSPAI4 XBATSPAI4
Modular test plug 10 XBATSPS5 XBATSPS5
Blank marker strip (strip of 10) White 10 XBMZBF5 1XBMZBF5 1
Description XBPTK25 XBPTK25PV
Technical Data in Accordance with IEC
Maximum load current in A/cross-section in mm228/4 28/4
Rated surge voltage in kV/contamination class 6/3 6/3
Surge voltage category/insulating material group III/I III/I
Connection Capacity
Stranded with ferrule with plastic sleeve in mm20.25–2.5 0.25–2.5
Stranded with ferrules without plastic sleeve in mm20.25–2.5 0.25–2.5
Stranded with twin ferrule with plastic sleeve in mm20.5 0.5
Stripping length in inches (mm) 0.39 (10) 0.39 (10)
Catalog
Number Width Length
Cover
Length
Height for—
35 x 7.5 in 35 x 15 in
XBPTK25 0.20 (5.2) 3.92 (99.5) 0.09 (2.2) 2.28 (58.0) 2.58 (65.5)
XBPTK25PV 0.20 (5.2) 3.92 (99.5) 0.09 (2.2) 2.28 (58.0) 2.58 (65.5)
V7-T8-48 Volume 7—Logic Control, Operator Interface and Connectivity Solutions CA08100008E—November 2011 www.eaton.com
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8.1
Terminal Blocks, Fuse Blocks and Fuse Holders
IECXB Series
Fuse Terminal Blocks
Contents
Description Page
Single Level—Through-Feed . . . . . . . . . . . . . . . . . V7-T8-32
Single Level—Ground Blocks . . . . . . . . . . . . . . . . . V7-T8-37
Multi-Conductor Terminal Blocks . . . . . . . . . . . . . V7-T8-39
Multi-Conductor Ground Blocks . . . . . . . . . . . . . . V7-T8-42
Double Level Blocks . . . . . . . . . . . . . . . . . . . . . . . V7-T8-44
Triple Level Blocks . . . . . . . . . . . . . . . . . . . . . . . . . V7-T8-46
Fuse Terminal Blocks
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . V7-T8-49
Technical Data and Specifications . . . . . . . . . . V7-T8-50
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . V7-T8-50
Disconnect and Component Terminal Blocks . . . . V7-T8-51
Hybrid Terminal Blocks . . . . . . . . . . . . . . . . . . . . . V7-T8-54
Mini Spring Cage . . . . . . . . . . . . . . . . . . . . . . . . . . V7-T8-56
Fuse Terminal Blocks
Product Description
The spring cage fuse terminal
blocks act as a fuse carrier for
5 x 20 mm or 6.3 x 32 mm
fuses. They also allow for
potential distribution with the
double bridge shaft. For
signaling a triggered fuse,
fuse terminal blocks with light
indicators are available (for
both AC and DC voltage).
Product Selection
Spring Cage Connection Fuse Terminal Blocks, for 5 x 20 mm Fuse
Notes
The cartridge fuse holders should be selected according to the maximum power dissipation (self-heating) of the cartridge
fuse inserts. The thermal conditions in closed fuse holes should be checked according to the application and installation.
Higher ambient temperatures are an additional strain on fuse inserts. In applications of this kind, the shift of the rated
current should be taken into consideration accordingly.
Maximum power dissipation at 73.4°F (23°C) (in accordance with IEC 60 947-7-3).
When selecting cartridge fuse inserts, please ensure that the maximum power dissipation specified at right is not exceeded.
Details can be obtained from the fuse suppliers.
Cartridge Fuse Inserts 5 x 20 and 6.3 x 32 mm in accordance. with IEC 60 947-7-3.
1 The current is determined by the fuse used, the voltage by the selected light indicator. See Page V7-T8-49.
Terminal
Width
Maximum
Wire Size
IEC 60 947-7-3
with Fuse
in V/A/AWG
IEC 60 947-7-3
as Disconnect
Terminal Blocks
in V/A/AWG
UL-cUL Ratings
in V/A/AWG Color
Standard
Pack
Catalog
Number
Fuse Terminal Blocks
6.2 mm 10 AWG/4 mm21/1/28–10 250/6.3/28–10 300/6.3/24–10 Black 50 XBPT4FBE
Fuse Terminal Blocks with LED 15–30V, 3.5–8.1A
6.2 mm 10 AWG/4 mm21/1/28–10 250/6.3/28–10 300/6.3/24–10 Black 50 XBPT4FBEL24
Fuse Terminal Blocks with LED 30–60V, 0.8–2.0A
6.2 mm 10 AWG/4 mm21/1/28–10 250/6.3/28–10 300/6.3/24–10 Black 50 XBPT4FBEL60
Fuse Terminal Blocks with LED 110–250V, 0.5–1.0A
6.2 mm 10 AWG/4 mm21/1/28–10 250/6.3/28–10 300/6.3/24–10 Black 50 XBPT4FBEL250
XBPT4FBE
Volume 7—Logic Control, Operator Interface and Connectivity Solutions CA08100008E—November 2011 www.eaton.com V7-T8-49
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8.1
Terminal Blocks, Fuse Blocks and Fuse Holders
IEC—XB Series
Spring Cage Connection Fuse Terminal Blocks, for 6.3 x 32 mm (1/4 in x 1–1/4 in) Fuse
Accessories
Spring Cage Connection Fuse Terminal Blocks
Notes
The cartridge fuse holders should be selected according to the maximum power dissipation (self-heating) of the cartridge
fuse inserts. The thermal conditions in closed fuse holes should be checked according to the application and installation.
Higher ambient temperatures are an additional strain on fuse inserts. In applications of this kind, the shift of the rated
current should be taken into consideration accordingly.
Maximum power dissipation at 73.4°F (23°C) (in accordance with IEC 60 947-7-3).
When selecting cartridge fuse inserts, please ensure that the maximum power dissipation specified at right is not exceeded.
Details can be obtained from the fuse suppliers.
Cartridge Fuse Inserts 5 x 20 and 6.3 x 32 mm in accordance. with IEC 60 947-7-3.
1For information on Printed Marking Tag Options, see Page V7-T8-98.
For additional accessories, see Page V7-T8-90.
Terminal
Width
Maximum
Wire Size
IEC 60 947-7-3
with Fuse
in V/A/AWG
IEC 60 947-7-3
as Disconnect
Terminal Blocks
in V/A/AWG
UL-cUL Ratings
in V/A/AWG Color
Standard
Pack
Catalog
Number
Fuse Terminal Blocks
8.2 mm 10 AWG/4 mm2400/10/28–10 400/10/28–10 300/10/24–10 Black 50 XBPT4FBN
Fuse Terminal Blocks with LED 12–30V, 1.0–2.5 mA
8.2 mm 10 AWG/4 mm2400/10/28–10 400/10/28–10 300/10/24–10 Black 50 XBPT4FBNL24
Fuse Terminal Blocks with LED 110–250V, 0.5–2.5 mA
8.2 mm 10 AWG/4 mm2400/10/28–10 400/10/28–10 300/10/24–10 Black 50 XBPT4FBNL250
Description Color
Number of
Positions
Standard
Pack
XBPT4FBE XBPT4FBN
Catalog
Number
Catalog
Number
Partition plate 10 XBATPT4 XBATQTD12
Plug-in bridge—for cross connections in
the bridge shaft
Red 2 10 XBAFBS26 XBAFBS28
310 XBAFBS36
510 XBAFBS56
10 10 XBAFBS106
Blank marker strip external labeling White 10 XBMZBF6 1XBMZBF8 1
Blank marker strip center labeling (strip of 10) White 10 XBMZB5 1XBMZB6 1
XBPT4FBN
V7-T8-50 Volume 7—Logic Control, Operator Interface and Connectivity Solutions CA08100008E—November 2011 www.eaton.com
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8.1
Terminal Blocks, Fuse Blocks and Fuse Holders
IECXB Series
Technical Data and Specifications
Overload and Short-Circuit Protection
Spring Cage Connection Fuse Terminal Blocks
Dimensions
Approximate Dimensions in Inches (mm)
Spring Cage Connection Fuse Terminal Blocks
Note
1The current is determined by the fuse used, the voltage by the selected light indicator. See Page V7-T8-49.
Terminal
Blocks
Overload Protection Short-Circuit Protection Only
U (V) Individual Interconnected Individual Interconnected Imax. (A)
XBPT4FBN 400 1.6W 1.6W 4W 2.5W 10.0
XBPT4FBE 250 1.6W 1.6W 4W 2.5W 6.3
Description XBPT4FBE XBPT4FBN
Technical Data in Accordance with IEC
Fuse type/dimensions in mm2G/5 x 20 G/6.3 x 32
Maximum current with single arrangement in A 6.3 10
Maximum Power Dissipation
At 73.4°F (23°C) in accordance with IEC 60 947-7-3 in W 11
Rated surge voltage in kV/contamination class 4/3 6/3
Surge voltage category/insulating material group III/I III/I
Connection Capacity
Stranded with ferrule/with ferrule and plastic sleeve in mm20.25–4/0.25–4 0.25–4/0.25–4
Stranded with twin ferrule and plastic sleeve in mm20.5 0.5
Stripping length in inches (mm) 0.39 (10) 0.39 (10)
Catalog
Number Width Length
Height for—
35 x 7.5 in 35 x 15 in
XBPT4FBE 0.24 (6.2) 2.42 (61.5) 2.46 (62.5) 2.76 (70.0)
XBPT4FBN 0.32 (8.2) 3.01 (76.5) 2.72 (69.0) 3.01 (76.5)
Volume 7—Logic Control, Operator Interface and Connectivity Solutions CA08100008E—November 2011 www.eaton.com V7-T8-51
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8.1
Terminal Blocks, Fuse Blocks and Fuse Holders
IEC—XB Series
Disconnect and Component Terminal Blocks
Contents
Description Page
Single Level—Through-Feed . . . . . . . . . . . . . . . . . V7-T8-32
Single Level—Ground Blocks . . . . . . . . . . . . . . . . . V7-T8-37
Multi-Conductor Terminal Blocks . . . . . . . . . . . . . . V7-T8-39
Multi-Conductor Ground Blocks . . . . . . . . . . . . . . V7-T8-42
Double Level Blocks . . . . . . . . . . . . . . . . . . . . . . . V7-T8-44
Triple Level Blocks . . . . . . . . . . . . . . . . . . . . . . . . . V7-T8-46
Fuse Terminal Blocks . . . . . . . . . . . . . . . . . . . . . . . V7-T8-48
Disconnect and Component Terminal Blocks
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . V7-T8-52
Technical Data and Specifications . . . . . . . . . . V7-T8-53
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . V7-T8-53
Hybrid Terminal Blocks . . . . . . . . . . . . . . . . . . . . . V7-T8-54
Mini Spring Cage . . . . . . . . . . . . . . . . . . . . . . . . . . V7-T8-56
Disconnect and Component Terminal Blocks
Product Description
The XBPT knife disconnect
terminal blocks feature
narrow construction and high
current carrying capacity.
They also have a test
connection parallel to the
disconnect point for a 2.3 mm
diameter test plug. Potential
distribution is easily
accomplished with the Plug-
in bridges. There are front
connection spring cage
terminal blocks available for
multi-conductor connections
in the smallest possible
space. The XBPT4TG
disconnect terminal block
accommodates component
plugs for resistors, diodes,
or capacitors, and fuse plugs
with or without indication.
Product Selection
Disconnect and Component Terminal Blocks
Terminal
Width
Maximum
Wire Size
IEC 60 947-7-1
in V/A/AWG
UL-cUL Ratings
in V/A/AWG Color
Standard
Pack
Catalog
Number
Single Level Knife Disconnect
5.2 mm 12 AWG/2.5 mm2400/16/28–12 600/16/26–12 Gray 50 XBPT25MT
6.2 mm 10 AWG/4 mm2400/16/28–10 300/6.3/24–10 Gray 50 XBPT4MT
Three-Wire Knife Disconnect
5.2 mm 12 AWG/2.5 mm2400/16/28–12 600/16/26–12 Gray 50 XBPT25D12MT
Four-Wire Knife Disconnect
5.2 mm 12 AWG/2.5 mm2400/16/28–12 600/16/26–12 Gray 50 XBPT25D22MT
Spring Cage Disconnect/Component Plug
6.2 mm 10 AWG/4 mm2400/16/28–10 300/6.3/24–10 Gray 50 XBPT4TG
Component Plug
6.2 mm 10 AWG/4 mm2400/16/28–10 300/6.3/24–10 Gray 10 XBPCO
Fuse Plug
6.2 mm 10 AWG/4 mm2400/16/28–10 300/6.3/24–10 Black 10 XBPFU
Fuse Plug with Light Indicator for 12–30V, 1–2.5 mA
6.2 mm 10 AWG/4 mm2400/16/28–10 300/6.3/24–10 Black 10 XBPFUL24
Fuse Plug with Light Indicator for 110–250V, 0.5–2.5 mA
6.2 mm 10 AWG/4 mm2400/16/28–10 300/6.3/24–10 Black 10 XBPFUL250
XBPT25MT
Knife Disconnect
V7-T8-52 Volume 7—Logic Control, Operator Interface and Connectivity Solutions CA08100008E—November 2011 www.eaton.com
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8.1
Terminal Blocks, Fuse Blocks and Fuse Holders
IECXB Series
Accessories
Spring Cage Connection Disconnect and Component Terminal Blocks
Notes
1For ordering information, see Page V7-T8-105.
2For information on Printed Marking Tag Options, see Page V7-T8-98.
3XBPT4MT and XBPT4TG have an enclosed design. The use of an end cover is not required.
For additional accessories, see Page V7-T8-90.
Description Color
Number of
Positions
Standard
Pack
XBPT25MT XBPT25D12MT XBPT25D22MT XBPT4MT XBPT4TG
Catalog
Number
Catalog
Number
Catalog
Number
Catalog
Number
Catalog
Number
End cover Gray 10 XBACPT25D12 XBACPT25D22 XBACPT25D22MT 33
End cover segment Gray 10 XBACPT25 XBACPT25
Partition plate XBATPTD12 XBATPTD22 XBATPT4 XBATPT4
Plug-in bridge—for cross connections
in the terminal center
Red 2 10 XBAFBS25 XBAFBS25 XBAFBS25 XBAFBS26 XBAFBS26
310XBAFBS35 XBAFBS35 XBAFBS35 XBAFBS36 XBAFBS36
510XBAFBS55 XBAFBS55 XBAFBS55 XBAFBS56 XBAFBS56
10 10 XBAFBS105 XBAFBS105 XBAFBS105 XBAFBS106 XBAFBS106
50 10 XBAFBS505 XBAFBS505 XBAFBS505 XBAFBS506 XBAFBS506
Test adapter 10 XBATSPAI4 XBATSPAI4 XBATSPAI4 XBATSPAI4 XBATSPAI4
2.3 mm diameter test plug XBATSMPS-_ 1XBATSMPS-_ 1XBATSMPS-_ 1XBATSMPS-_ 1XBATSMPS-_ 1
Modular test plug 10 XBATSPS5 XBATSPS5 XBATSPS5 XBATSPS6 XBATSPS6
Blank marker strip external labeling White 10 XBMZBF5 2XBMZBF5 2XBMZBF5 2XBMZBF6 2XBMZBF6 2
Blank marker strip center labeling
(strip of 10)
White 10 XBMZB5 2XBMZB5 2XBMZB5 2XBMZB6 2XBMZB6 2
Volume 7—Logic Control, Operator Interface and Connectivity Solutions CA08100008E—November 2011 www.eaton.com V7-T8-53
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8.1
Terminal Blocks, Fuse Blocks and Fuse Holders
IEC—XB Series
Technical Data and Specifications
Spring Cage Connection Disconnect and Component Terminal Blocks,
XBPT25MT, XBPT25D12MT and XBPT25D22MT
Spring Cage Connection Disconnect and Component Terminal Blocks,
XBPT25D12MT and XBPT4TG
Dimensions
Approximate Dimensions in Inches (mm)
Spring Cage Connection Disconnect and Component Terminal Blocks
Description XBPT25MT XBPT25D12MT XBPT25D22MT
Technical Data in Accordance with IEC
Maximum load current in A/cross-section in mm216/4 16/4 16/4
Rated surge voltage in kV/contamination class 6/3 6/3 6/3
Surge voltage category/insulating material group III/I III/I III/I
Connection Capacity
Stranded with ferrule with plastic sleeve in mm20.25–2.5 0.25–2.5 0.25–2.5
Stranded with ferrules without plastic sleeve in mm20.25–2.5 0.25–2.5 0.25–2.5
Stranded with twin ferrule with plastic sleeve in mm20.5 0.5 0.5
Stripping length in inches (mm) 0.39 (10) 0.39 (10) 0.39 (10)
Description XBPT4MT XBPT4TG
Technical Data in Accordance with IEC
Maximum load current in A/cross-section in mm216/6 16/6
Rated surge voltage in kV/contamination class 6/3 6/3
Surge voltage category/insulating material group III/I III/I
Connection Capacity
Stranded with ferrule with plastic sleeve in mm20.25–4 0.25–4
Stranded with ferrules without plastic sleeve in mm20.25–4 0.25–4
Stranded with twin ferrule with plastic sleeve in mm20.5 0.5
Stripping length in inches (mm) 0.39 (10) 0.39 (10)
Catalog
Number Width Length
Cover
Length
Height for—
35 x 7.5 in 35 x 15 in
XBPT25MT 0.20 (5.2) 2.38 (60.5) 0.09 (2.2) 1.44 (36.5) 1.73 (44.0)
XBPT25D12MT 0.20 (5.2) 2.83 (72.0) 0.09 (2.2) 1.44 (36.5) 1.73 (44.0)
XBPT25D22MT 0.20 (5.2) 3.31 (84.0) 0.09 (2.2) 1.44 (36.5) 1.73 (44.0)
XBPT4MT 0.24 (6.2) 2.42 (61.5) 1.44 (36.5) 1.73 (44.0)
XBPT4TG 0.24 (6.2) 2.42 (61.5) 1.44 (36.5) 1.73 (44.0)
V7-T8-54 Volume 7—Logic Control, Operator Interface and Connectivity Solutions CA08100008E—November 2011 www.eaton.com
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8.1
Terminal Blocks, Fuse Blocks and Fuse Holders
IECXB Series
Hybrid Terminal Blocks
Contents
Description Page
Single Level—Through-Feed . . . . . . . . . . . . . . . . . V7-T8-32
Single Level—Ground Blocks . . . . . . . . . . . . . . . . . V7-T8-37
Multi-Conductor Terminal Blocks . . . . . . . . . . . . . V7-T8-39
Multi-Conductor Ground Blocks . . . . . . . . . . . . . . V7-T8-42
Double Level Blocks . . . . . . . . . . . . . . . . . . . . . . . V7-T8-44
Triple Level Blocks . . . . . . . . . . . . . . . . . . . . . . . . . V7-T8-46
Fuse Terminal Blocks . . . . . . . . . . . . . . . . . . . . . . . V7-T8-48
Disconnect and Component Terminal Blocks . . . . V7-T8-51
Hybrid Terminal Blocks
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . V7-T8-55
Technical Data and Specifications . . . . . . . . . . V7-T8-55
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . V7-T8-55
Mini Spring Cage . . . . . . . . . . . . . . . . . . . . . . . . . . V7-T8-56
Hybrid Terminal Blocks
Product Description
The XBPU spring cage hybrid
terminal blocks offer the best
of both worlds. One side
offers a spring cage
connection and the other side
offers the universal screw
connection. Use the spring
cage connection on the
internal (factory) control
cabinet side and the screw
connection on the end
customer (field) side. Ground
terminal blocks of the same
shape are also available.
Product Selection
Spring Cage Hybrid Terminal Blocks
Spring Cage Hybrid Ground Blocks
Terminal
Width
Maximum
Wire Size
IEC 60 947-7-1 with … IEC 60 947-7-2 with … UL-cUL Ratings with …
Color
Std.
Pack
Catalog
Number
Spring in
V/A/AWG
Screw in
V/A/AWG
Spring in
V/A/AWG
Screw in
V/A/AWG
Spring in
V/A/AWG
Screw in
V/A/AWG
5.2 mm 12 AWG/
2.5 mm2
800/28/28–12 800/28/26–14 600/15/28–12 600/15/26–12 Gray 50 XBPU25D12
Terminal
Width
Maximum
Wire Size
IEC 60 947-7-1 with … IEC 60 947-7-2 with … UL-cUL Ratings with …
Color
Std.
Pack
Catalog
Number
Spring in
V/A/AWG
Screw in
V/A/AWG
Spring in
V/A/AWG
Screw in
V/A/AWG
Spring in
V/A/AWG
Screw in
V/A/AWG
5.2 mm 12 AWG/
2.5 mm2
—/—/28–12 —/—/26–14 —/—/28–12 —/—/28–12 Green/
Yellow
50 XBPU25D12PE
XBPU25D12
XBPU25D12PE
Volume 7—Logic Control, Operator Interface and Connectivity Solutions CA08100008E—November 2011 www.eaton.com V7-T8-55
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8.1
Terminal Blocks, Fuse Blocks and Fuse Holders
IEC—XB Series
Accessories
Spring Cage Hybrid Terminal/Ground Blocks
Technical Data and Specifications
Spring Cage Hybrid Blocks
Dimensions
Approximate Dimensions in Inches (mm)
Spring Cage Hybrid Blocks
Notes
1For ordering information, see Page V7-T8-105.
2For information on Printed Marking Tag Options, see Page V7-T8-98.
For additional accessories, see Page V7-T8-90.
Description Color
Number of
Positions
Standard
Pack
XBPU25D12 XBPU25D12PE
Catalog
Number
Catalog
Number
End cover Gray 10 XBACPU25D12 XBACPU25D12
Plug-in bridge—for cross connections
in the terminal center
Red 2 10 XBAFBS25 XBAFBS25
310XBAFBS35 XBAFBS35
510XBAFBS55 XBAFBS55
10 10 XBAFBS105 XBAFBS105
50 10 XBAFBS505 XBAFBS505
Test adapter 10 XBATSPAI4
2.3 mm diameter test plug XBATSMPS-_ 1
Modular test plug 10 XBATSPS5
Blank marker strip external labeling White 10 XBMZBF5 2XBMZBF5 2
Blank marker strip center labeling
(strip of 10)
White 10 XBMZB5 2XBMZB5 2
Description XBPU25D12 XBPU25D12PE
Technical Data in Accordance with IEC
Maximum load current in A/cross-section in mm228/4
Rated surge voltage in kV/contamination class 8/3 8/3
Surge voltage category/insulating material group III/I III/I
Connection Capacity
Stranded with ferrule with plastic sleeve in mm20.25–2.5 0.25–2.5
Stranded with ferrules without plastic sleeve in mm20.25–2.5 0.25–2.5
Stranded with twin ferrule with plastic sleeve in mm20.5–1 0.5–1
Stripping length in inches (mm) 0.39 (10) 0.39 (10)
Catalog
Number Width Length
Cover
Length
Height for—
35 x 7.5 in 35 x 15 in
XBPU25D12 0.20 (5.2) 2.57 (65.3) 0.09 (2.2) 1.69 (42.8) 1.98 (50.3)
XBPU25D12PE 0.20 (5.2) 2.57 (65.3) 0.09 (2.2) 1.69 (42.8) 1.98 (50.3)
V7-T8-56 Volume 7—Logic Control, Operator Interface and Connectivity Solutions CA08100008E—November 2011 www.eaton.com
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8.1
Terminal Blocks, Fuse Blocks and Fuse Holders
IECXB Series
Mini Spring Cage
Contents
Description Page
Single Level—Through-Feed . . . . . . . . . . . . . . . . . V7-T8-5
Single Level—Ground Blocks . . . . . . . . . . . . . . . . V7-T8-10
Multi-Conductor Terminal Blocks . . . . . . . . . . . . . V7-T8-12
Multi-Conductor Ground Blocks . . . . . . . . . . . . . . V7-T8-14
Double Level . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V7-T8-16
Triple Level Sensor/Actuator . . . . . . . . . . . . . . . . . V7-T8-18
Fuse Terminal Blocks . . . . . . . . . . . . . . . . . . . . . . . V7-T8-21
Disconnect and Component Terminal Blocks . . . . V7-T8-24
High Current Blocks . . . . . . . . . . . . . . . . . . . . . . . V7-T8-27
Mini Spring Cage
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . V7-T8-57
Technical Data and Specifications . . . . . . . . . . V7-T8-57
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . V7-T8-57
Mini Spring Cage
Product Description
The XB miniature terminal
blocks have a connection
cross-section from 1.5 mm2
through 4 mm2 and mount on
15 mm DIN rail. There is an
opening for bridging with a
fixed bridge in the center of
the terminal blocks. These
miniature terminal blocks also
offer the same accessories
that you would find with the
larger blocks—including
marking tags, end covers,
end stop and ground blocks.
Product Selection
Mini Spring Cage Terminal Blocks
Mini Spring Cage Ground Blocks
Mini Spring Cage Terminal Blocks—Double Level
Terminal
Width
Maximum
Wire Size
IEC 60 947-7-1
in V/A/AWG
IEC 60 947-7-2
in V/A/AWG
UL-cUL Ratings
in V/A/AWG Color
Standard
Pack
Catalog
Number
5.2 mm 14 AWG/1.5 mm2800/24/26–14 600/15/26–14 Gray 50 XBMPK15
Blue 50 XBMPK15BU
Terminal
Width
Maximum
Wire Size
IEC 60 947-7-1
in V/A/AWG
IEC 60 947-7-2
in V/A/AWG
UL-cUL Ratings
in V/A/AWG Color
Standard
Pack
Catalog
Number
5.2 mm 14 AWG/1.5 mm2 —/—/26–14 —/—/26–14 Green/
Yellow
50 XBMPK15PE
Terminal
Width
Maximum
Wire Size
IEC 60 947-7-1
in V/A/AWG
UL-cUL Ratings
in V/A/AWG Color
Standard
Pack
Catalog
Number
5.2 mm 14 AWG/1.5 mm2500/20/26–14 600/15/26–14 Gray 50 XBMPKK15
XBMPK15
XBMPK15PE
XBMPKK15
Volume 7—Logic Control, Operator Interface and Connectivity Solutions CA08100008E—November 2011 www.eaton.com V7-T8-57
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8.1
Terminal Blocks, Fuse Blocks and Fuse Holders
IEC—XB Series
Accessories
Mini Spring Cage Terminal/Ground Blocks
Technical Data and Specifications
Mini Spring Cage Terminal/Ground Blocks
Dimensions
Approximate Dimensions in Inches (mm)
Mini Spring Cage Terminal/Ground Blocks
Notes
1For information on Printed Marking Tag Options, see Page V7-T8-98.
For additional accessories, see Page V7-T8-90.
Description Color
Number of
Positions
Standard
Pack
XBMPK15 XBMPK15PE XBMPKK15
Catalog
Number
Catalog
Number
Catalog
Number
End cover Gray 10 XBACMPK15 XBACMPK15 XBACMPKK15
Fixed bridge 2 10 XBAFBR25N XBAFBR25N
Separating plate 10 XBATMPKK15 XBATMPKK15
Blank marker strip White 10 XBMZBF5 1XBMZBF5 1XBMZBF5 1
Description XBMPK15 XBMPK15PE XBMPKK15
Technical Data in Accordance with IEC
Maximum load current in A/cross-section in mm224/2.5 20/2.5
Rated surge voltage in kV/contamination class 8/3 8/3 6/3
Surge voltage category/insulating material group III/I III/I III/I
Connection Cross-Section
Stranded with ferrule with plastic sleeve in mm20.25–1.5 0.25–1.5 0.25–1.5
Stranded with ferrule without plastic sleeve in mm20.25–1.5 0.25–1.5 0.25–1.5
Stranded with twin ferrule with plastic sleeve in mm2———
Stripping length in Inches (mm) 0.35 (9) 0.35 (9) 0.35 (9)
Catalog
Number Width Length
Cover
Length
Height for—
15 x 5.5 in 35 x 7.5 in 35 x 15 in
XBMPK15 0.20 (5.2) 1.57 (40.0) 0.04 (1.1) 1.36 (34.5)
XBMPK15PE 0.20 (5.2) 1.57 (40.0) 0.04 (1.1) 1.36 (34.5)
XBMPKK15 0.20 (5.2) 3.35 (85.0) 0.04 (1.1) 1.65 (42.0) 1.67 (42.5) 1.97 (50.0)
V7-T8-58 Volume 7—Logic Control, Operator Interface and Connectivity Solutions CA08100008E—November 2011 www.eaton.com
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8.1
Terminal Blocks, Fuse Blocks and Fuse Holders
IECXB Series
Pluggable Spring Cage Terminal Blocks
Contents
Description Page
Pluggable Spring Cage Terminal Blocks
Connection Terminal Blocks . . . . . . . . . . . . . . . V7-T8-59
Connection Plugs . . . . . . . . . . . . . . . . . . . . . . . V7-T8-62
Connection Receptacles . . . . . . . . . . . . . . . . . V7-T8-64
Connection Accessories . . . . . . . . . . . . . . . . . V7-T8-66
Drawings
Online
Pluggable Spring Cage Terminal Blocks Overview
Product Description
The pluggable spring cage
connection terminal blocks
allow signal and power wiring
to be made pluggable. This
complete pluggable system
has a spring that provides
maximum connection space
in a space-saving design.
The pluggable system
accommodates stranded
conductors with a nominal
cross-section of 2.5 mm2,
with or without ferrules.
Application Description
For applications requiring
pluggable wiring up to a rated
current of 32A and a rated
voltage of 800V. The
integrated overspring meets
the most stringent vibration
requirements. Also ideal
where safety is a concern and
flexibility is required. The
basic terminal blocks and the
plugs are finger-safe, which
also means the supply
voltage can be input via either
the terminal blocks or the
plugs. With the XBAPSC
receptacles, plug-in contacts
can be accommodated safely
in cable ducts and distributor
shafts using minimal space.
A test hole can accommodate
a 2.3 mm diameter test plug
in each receptacle, providing
a practical solution. The
XBAPSP plugs are intended
for connecting one wire,
while the XBAPSPDB plugs
are designed to connect
two wires and provide an
optional bridge.
Features
Space-saving design
Powerful contact
Finger-safe
Pluggability
Standards and Certifications
UL recognized—File No.
E67464
CE approved
LVD 1:
EN 60947-7-1
EN 60947-7-2
EN 60998-2-3
EN 60352-4/A1
ATEX approval
(Eex e applications)
Note
1Not all standards apply to all terminal
blocks. Contact Eaton for details.
Volume 7—Logic Control, Operator Interface and Connectivity Solutions CA08100008E—November 2011 www.eaton.com V7-T8-59
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8.1
Terminal Blocks, Fuse Blocks and Fuse Holders
IEC—XB Series
Connection Terminal Blocks
Contents
Description Page
Connection Terminal Blocks
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . V7-T8-60
Technical Data and Specifications . . . . . . . . . . V7-T8-60
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . V7-T8-61
Connection Plugs . . . . . . . . . . . . . . . . . . . . . . . . . V7-T8-62
Connection Receptacles . . . . . . . . . . . . . . . . . . . . V7-T8-64
Connection Accessories . . . . . . . . . . . . . . . . . . . . V7-T8-66
Connection Terminal Blocks
Product Description
Contact to the DIN rail is
made by simply snapping the
terminal block onto the rail.
These blocks act as the
stationary position of the
pluggable terminal blocks.
Product Selection
Pluggable Spring Cage Connection Terminal Blocks
Terminal
Width
Maximum
Wire Size
IEC 61 984
in V/A/AWG
UL-cUL Ratings
in V/A/AWG Color
Standard
Pack
Catalog
Number
Single Level
5.2 mm 12 AWG/2.5 mm2500/24/28–12 300/20/26–12 Gray 50 XBPT25P
Three-Wire
5.2 mm 12 AWG/2.5 mm2500/24/28–12 300/20/26–12 Gray 50 XBPT25PD12
XBPT25P
V7-T8-60 Volume 7—Logic Control, Operator Interface and Connectivity Solutions CA08100008E—November 2011 www.eaton.com
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8.1
Terminal Blocks, Fuse Blocks and Fuse Holders
IECXB Series
Accessories
Pluggable Spring Cage Connection Terminal Blocks
Technical Data and Specifications
Pluggable Spring Cage Connection Terminal Blocks Derating Curve for Pluggable Terminal Blocks
XBPT25P and XBPT25PD12
Notes
1For ordering information, see Page V7-T8-105.
2For information on Printed Marking Tag Options, see Page V7-T8-98.
For additional accessories, see Page V7-T8-90.
Description Color
Number of
Positions
Standard
Pack
XBPT25P XBPT25PD12
Catalog
Number
Catalog
Number
End cover Gray 10 XBACPT25 XBACPT25D12
End cover segment Gray 10 XBASPT25
Partition plate 10 XBATPT4 XBATPTD12
Plug-in bridge—for cross connections
in the terminal center
Red 2 10 XBAFBS25 XBAFBS25
310XBAFBS35 XBAFBS35
510XBAFBS55 XBAFBS55
10 10 XBAFBS105 XBAFBS105
50 10 XBAFBS505 XBAFBS505
Test adapter 10 XBATSPAI4 XBATSPAI4
2.3 mm diameter test plug XBATSMPS-_ 1XBATSMPS-_ 1
Modular test plug 10 XBATSPS5 XBATSPS5
Blank marker strip external labeling White 10 XBMZBF5 2XBMZBF5 2
Blank marker strip center labeling (strip of 10) White 10 XBMZB5 2XBMZB5 2
Description XBPT25P XBPT25PD12
Technical Data in Accordance with IEC
Maximum load current in A/cross-section in mm224/4 24/4
Rated surge voltage in kV/contamination class 6/3 6/3
Surge voltage category/insulating material group III/I III/I
Connection Capacity
Stranded with ferrule with plastic sleeve in mm20.25–2.5 0.25–2.5
Stranded with ferrules without plastic sleeve in mm20.25–2.5 0.25–2.5
Stranded with twin ferrule with plastic sleeve in mm20.5 0.5
Stripping length in inches (mm) 0.39 (10) 0.39 (10)
25
15 pos.
5 pos.
20
15
10
5
0
Ambient Temperature °C
Maximum Load Current – A
020406080100120
10 pos.
2 pos.
Volume 7—Logic Control, Operator Interface and Connectivity Solutions CA08100008E—November 2011 www.eaton.com V7-T8-61
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8.1
Terminal Blocks, Fuse Blocks and Fuse Holders
IEC—XB Series
Dimensions
Approximate Dimensions in Inches (mm)
Pluggable Spring Cage Connection Terminal Blocks—Without Plug
XBPT25P
XBPT25PD12
Catalog
Number Width Length
Cover
Length
Height for—
35 x 7.5 in 35 x 15 in
XBPT25P 0.20 (5.2) 1.91 (48.5) 0.09 (2.2) 1.44 (36.5) 1.73 (44.0)
XBPT25PD12 0.20 (5.2) 2.38 (60.5) 0.09 (2.2) 1.44 (36.5) 1.73 (44.0)
1.99 (50.5)
2.42
(61.5)
2.42 (61.5)
2.42
(61.5)
V7-T8-62 Volume 7—Logic Control, Operator Interface and Connectivity Solutions CA08100008E—November 2011 www.eaton.com
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8.1
Terminal Blocks, Fuse Blocks and Fuse Holders
IECXB Series
Connection Plugs
Contents
Description Page
Connection Terminal Blocks . . . . . . . . . . . . . . . . . V7-T8-59
Connection Plugs
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . V7-T8-63
Technical Data and Specifications . . . . . . . . . . V7-T8-63
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . V7-T8-63
Connection Receptacles . . . . . . . . . . . . . . . . . . . . V7-T8-64
Connection Accessories . . . . . . . . . . . . . . . . . . . . V7-T8-66
Connection Plugs
Product Description
Just like the basic terminal
blocks, the plugs also offer
the perfect solution for every
application. The XBAPSP25_
plugs are designed for
connecting one conductor.
The XBAPSPDB25_ plug is
designed for connecting two
conductors and provides an
additional bridging option.
Product Selection
Spring Cage Connection Plugs, Single, Not Bridgeable
Terminal
Width
Maximum
Wire Size
Connection Data
in V/A/AWG
UL-cUL Ratings
in V/A/AWG Color
Number of
Positions
Standard
Pack
Catalog
Number
5.2 mm 12 AWG/2.5 mm2500/24/28–12 300/20/26–12 Gray 1 25 XBAPSP251
225 XBAPSP252
325 XBAPSP253
425 XBAPSP254
525 XBAPSP255
625 XBAPSP256
725 XBAPSP257
825 XBAPSP258
925 XBAPSP259
10 25 XBAPSP2510
11 10 XBAPSP2511
12 10 XBAPSP2512
XBAPSP25_
Volume 7—Logic Control, Operator Interface and Connectivity Solutions CA08100008E—November 2011 www.eaton.com V7-T8-63
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8.1
Terminal Blocks, Fuse Blocks and Fuse Holders
IEC—XB Series
Spring Cage Connection Plugs, Double, Bridgeable
Accessories
Spring Cage Connection Plugs
Technical Data and Specifications
Spring Cage Connection Plugs
Dimensions
See Page V7-T8-61 for dimensions.
Notes
1For information on Printed Marking Tag Options, see Page V7-T8-98.
For additional accessories, see Page V7-T8-90.
Terminal
Width
Maximum
Wire Size
Connection Data
in V/A/AWG
UL-cUL Ratings
in V/A/AWG Color
Number of
Positions
Standard
Pack
Catalog
Number
5.2 mm 12 AWG/2.5 mm2500/24/28–12 300/20/26–12 Gray 1 25 XBAPSPDB251
225 XBAPSPDB252
325 XBAPSPDB253
425 XBAPSPDB254
525 XBAPSPDB255
625 XBAPSPDB256
725 XBAPSPDB257
825 XBAPSPDB258
925 XBAPSPDB259
10 25 XBAPSPDB2510
11 10 XBAPSPDB2511
12 10 XBAPSPDB2512
Description Color
Number of
Positions
Standard
Pack
XBAPSP25_ XBAPSPDB25_
Catalog
Number
Catalog
Number
Plug-in bridge—for cross connections
in the terminal center
Red 2 10 XBAFBS25
310 XBAFBS35
510 XBAFBS55
10 10 XBAFBS105
Snap-lock fitting and strain relief Orange 2 10 XBAPPRZ XBAPPRZ
Snap-lock fitting Orange 1 10 XBAPPR XBAPPR
Orange 2 10 XBAPPR2 XBAPPR2
Strain relief Black 2 10 XBAPPZ2 XBAPPDZ2
Black 4 10 XBAPPZ4 XBAPPDZ4
Blank marker strip White 10 XBMZBF5 1XBMZBF5 1
Description XBAPSP25_ XBAPSPDB25_
Technical Data in Accordance with IEC
Maximum load current in A/cross-section in mm224/4 24/4
Rated surge voltage in kV/contamination class 6/3 6/3
Surge voltage category/insulating material group III/I III/I
Connection Capacity
Stranded with ferrule with plastic sleeve in mm20.25–2.5 0.25–2.5
Stranded with ferrules without plastic sleeve in mm20.25–2.5 0.25–2.5
Stranded with twin ferrule with plastic sleeve in mm20.5 0.5
Stripping length in inches (mm) 0.39 (10) 0.39 (10)
XBAPSPDB25_
V7-T8-64 Volume 7—Logic Control, Operator Interface and Connectivity Solutions CA08100008E—November 2011 www.eaton.com
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8.1
Terminal Blocks, Fuse Blocks and Fuse Holders
IECXB Series
Connection Receptacles
Contents
Description Page
Connection Terminal Blocks . . . . . . . . . . . . . . . . . V7-T8-59
Connection Plugs . . . . . . . . . . . . . . . . . . . . . . . . . V7-T8-62
Connection Receptacles
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . V7-T8-65
Technical Data and Specifications . . . . . . . . . . V7-T8-65
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . V7-T8-65
Connection Accessories . . . . . . . . . . . . . . . . . . . . V7-T8-66
Connection Receptacles
Product Description
With the XBAPSC25_,
Plug-in contacts can be
accommodated safely in
cable ducts and distributor
shafts without using much
space. The standard strain
reliefs can also be used.
Large-surface labeling makes
it possible to mark the
terminal points and the entire
receptacle. A test hole can
accommodate a 2.3 mm
diameter test plug in each
receptacle element, providing
a practical solution.
Product Selection
Pluggable Spring Connection Receptacles
Terminal
Width
Maximum
Wire Size
Connection Data
in V/A/AWG
UL-cUL Ratings
in V/A/AWG Color
Number of
Positions
Standard
Pack
Catalog
Number
5.2 mm 12 AWG/2.5 mm2500/24/28–12 300/20/26–12 Gray 2 25 XBAPSC252
325 XBAPSC253
425 XBAPSC254
525 XBAPSC255
625 XBAPSC256
725 XBAPSC257
825 XBAPSC258
925 XBAPSC259
10 25 XBAPSC2510
11 10 XBAPSC2511
12 10 XBAPSC2512
XBAPSC25_
Volume 7—Logic Control, Operator Interface and Connectivity Solutions CA08100008E—November 2011 www.eaton.com V7-T8-65
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8.1
Terminal Blocks, Fuse Blocks and Fuse Holders
IEC—XB Series
Accessories
Pluggable Spring Connection Receptacles
Technical Data and Specifications
Spring Cage Connection Plugs
Dimensions
Approximate Dimensions in Inches (mm)
Spring Cage Connection Plugs
Receptacle Widths
Notes
1For ordering information, see Page V7-T8-105.
2For information on Printed Marking Tag Options, see Page V7-T8-98.
For additional accessories, see Page V7-T8-90.
Description Color
Number of
Positions
Standard
Pack
XBAPSC25_
Catalog
Number
2.3 mm diameter test plug Red XBATSMPS-_ 1
Strain relief Black 2 10 XBAPPDZ2
Black 4 10 XBAPPDZ4
Blank marker strip White 10 XBMZBF5 2
Description XBAPSP25_
Technical Data in Accordance with IEC
Maximum load current in A/cross-section in mm224/4
Rated surge voltage in kV/contamination class 6/3
Surge voltage category/insulating material group III/I
Connection Capacity
Stranded with ferrule with plastic sleeve in mm20.25–2.5
Stranded with ferrules without plastic sleeve in mm20.25–2.5
Stranded with twin ferrule with plastic sleeve in mm20.5
Stripping length in inches (mm) 0.39 (10)
Catalog
Number Width Length
Cover
Length Height
XBAPSP25_ 0.20 (5.2) 1.46 (37.2) 0.09 (2.2) 0.71 (18.0)
Catalog
Number Width
Catalog
Number Width
XBAPSC252 0.41 (10.4) XBAPSC258 1.64 (41.6)
XBAPSC253 0.61 (15.6) XBAPSC259 1.84 (46.8)
XBAPSC254 0.82 (20.8) XBAPSC2510 2.05 (52.0)
XBAPSC255 1.02 (26.0) XBAPSC2511 2.25 (57.2)
XBAPSC256 1.23 (31.2) XBAPSC2512 2.46 (62.4)
XBAPSC257 1.43 (36.4)
V7-T8-66 Volume 7—Logic Control, Operator Interface and Connectivity Solutions CA08100008E—November 2011 www.eaton.com
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8.1
Terminal Blocks, Fuse Blocks and Fuse Holders
IECXB Series
Connection Accessories
Product Description
The pluggable XBPT series
features an extensive range
of application-oriented
accessories. Strain reliefs are
available for the plugs and
can be snapped on at the
required points as an option.
The snap-lock fitting can be
used for all plug variants. It is
snapped into the outside of
the plug housing as an option
and hooks onto the terminal
block housing when the plug
is snapped on.
Product Selection
Pluggable Spring Cage Connection Accessories
Strain Relief Snap-Lock Fitting
Optional Accessory Recommendations
Description
Number of
Positions
Standard
Pack
Catalog
Number
Strain relief for single plugs 2 10 XBAPPZ2
410XBAPPZ4
Strain relief for double plugs and receptacles 2 10 XBAPPDZ2
410XBAPPDZ4
Snap-lock fitting for plugs 1 10 XBAPPR
210XBAPPR2
Snap-lock fitting and strain relief for plugs 2 10 XBAPPRZ
Number of Positions
Receptacle Strain Relief
2–4 XBAPPZ2
5–10 XBAPPZ4 or (2) XBAPPZ2
11–15 (2) XBAPPZ4 or (4) XBAPPZ2
XBAPPZ2
XBAPPDZ4
XBAPPR2
XBAPPRZ
Volume 7—Logic Control, Operator Interface and Connectivity Solutions CA08100008E—November 2011 www.eaton.com V7-T8-67
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8.1
Terminal Blocks, Fuse Blocks and Fuse Holders
IEC—XB Series
IDC Terminal Blocks
Contents
Description Page
IDC Terminal Blocks
Single Level . . . . . . . . . . . . . . . . . . . . . . . . . . . V7-T8-68
Multi-Conductor . . . . . . . . . . . . . . . . . . . . . . . . V7-T8-70
Double Level . . . . . . . . . . . . . . . . . . . . . . . . . . . V7-T8-73
Fuse Terminal Blocks . . . . . . . . . . . . . . . . . . . . V7-T8-75
Disconnect and Component Terminal Blocks . . V7-T8-77
Hybrid Terminal Blocks . . . . . . . . . . . . . . . . . . . V7-T8-79
Drawings
Online
IDC (Insulation Displacement Connection) Terminal Blocks Overview
Product Description
The superior design of
Eaton’s Insulation
Displacement Connection
(IDC) technology terminal
blocks reduces wiring
installation time and labor,
especially in high-volume
applications. IDC terminal
blocks are suited for
applications in automated
equipment and machine
tools, packaging and material
handling machinery, railway/
mass transit systems, petro-
chemical, and any other
application requiring high-
volume connections for low-
voltage control and signal
circuitry where labor cost
reduction and ease of
assembly is desired. These
terminal blocks are designed
for long-term use under
demanding conditions.
The XBQT Series allows for
wire to be connected without
any prior stripping. The quick
connection provides up to
60% reduction in wiring time.
One turn of a standard
screwdriver results in a
simple, fast and reliable
connection.
Application Description
The XBQT is operated with a
standard screwdriver. The
switching states are clearly
signaled by engagement
points in the start and end
positions. Solid and stranded
wires of 0.25 to 2.5 mm2 can
be wired without the use of
ferrules. Stripping the wire is
not required—the wire's
insulation is cut open when it
is properly connected. The
wire is securely placed in the
end position where it makes
large-area, gas-tight contact.
Connections are made in
seconds!
Features
Quick connection capability
Global acceptance
Flexible plug-in bridge
system
Large surface area for
marking
Standardized testing
system
Standards and Certifications
UL recognized—File No.
E67464
CE approved
LVD 1
EN 60947-7-1
EN 60947-7-2
EN 60998-2-3
EN 60352-4/A1
ATEX approval
(Eex e applications)
Note
1Not all standards apply to all terminal
blocks. Contact Eaton for details.
V7-T8-68 Volume 7—Logic Control, Operator Interface and Connectivity Solutions CA08100008E—November 2011 www.eaton.com
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8.1
Terminal Blocks, Fuse Blocks and Fuse Holders
IECXB Series
Single Level
Contents
Description Page
Single Level
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . V7-T8-69
Technical Data and Specifications . . . . . . . . . . V7-T8-69
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . V7-T8-69
Multi-Conductor . . . . . . . . . . . . . . . . . . . . . . . . . . V7-T8-70
Double Level . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V7-T8-73
Fuse Terminal Blocks . . . . . . . . . . . . . . . . . . . . . . . V7-T8-75
Disconnect and Component Terminal Blocks . . . . V7-T8-77
Hybrid Terminal Blocks . . . . . . . . . . . . . . . . . . . . . V7-T8-79
Single Level
Product Description
The XBQT IDC terminal block
has the fastest connection
time in a compact design.
The space-saving front
connection design offers
additional space for wiring
between the cable ducts.
The double bridge shaft can
accommodate individual
chain bridging and step-down
bridging from other terminal
blocks. The XBQT ground
blocks are the same shape
as the feed-through terminal
blocks with the same wide
range of cross-sections
available. They easily snap
onto the DIN rail to make
a reliable mechanical and
electrical contact that
meets all requirements
of IEC 60-947-7-2.
Product Selection
IDC—Single Level Terminal Blocks
IDC—Single Level Terminal Ground Blocks
Note
1 EU type—examination certificate number: KEMA 05ATEX2157 U (XBQT15), KEMA 05ATEX2160 U (XBQT25).
Terminal
Width
Maximum
Wire Size
Connection Data
in V/A/AWG
EN 50 019 1
in V/A/AWG
UL-cUL Ratings
in V/A/AWG Color
Standard
Pack
Catalog
Number
5.2 mm 16 AWG/1.5 mm2800/17.5/24–16 550/16/24–16 600/10/24–16 Gray 50 XBQT15
Blue 50 XBQT15BU
6.2 mm 14 AWG/2.5 mm2800/24/20–14 600/15/20–14 Gray 50 XBQT25
Blue 50 XBQT25BU
Terminal
Width
Maximum
Wire Size
Connection Data
in V/A/AWG
EN 50 019 1
in V/A/AWG
UL-cUL Ratings
in V/A/AWG Color
Standard
Pack
Catalog
Number
5.2 mm 16 AWG/1.5 mm2—/—/24–16 —/—/24–16 —/—/24–16 Green/Yellow 50 XBQT15PE
6.2 mm 14 AWG/2.5 mm2—/—/20–14 —/—/20–14 Green/Yellow 50 XBQT25PE
XBQT25
XBQT15PE
Volume 7—Logic Control, Operator Interface and Connectivity Solutions CA08100008E—November 2011 www.eaton.com V7-T8-69
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8.1
Terminal Blocks, Fuse Blocks and Fuse Holders
IEC—XB Series
Accessories
IDC—Single Level Terminal/Ground Blocks
Technical Data and Specifications
IDC—Single Level Terminal/Ground Blocks
Dimensions
Approximate Dimensions in Inches (mm)
IDC—Single Level Terminal/Ground Blocks
Notes
1For ordering information, see Page V7-T8-105.
2For information on Printed Marking Tag Options, see Page V7-T8-98.
For additional accessories, see Page V7-T8-90.
Description Color
Number of
Positions
Standard
Pack
XBQT15 XBQT25 XBQT15PE XBQT25PE
Catalog
Number
Catalog
Number
Catalog
Number
Catalog
Number
End cover Gray 10 XBACQT15 XBACQT25 XBACQT15 XBACQT25
Partition plate 10 XBATQT25 XBATQT25 XBATQT25 XBATQT25
Plug-in bridge Red 2 10 XBAFBS25 XBAFBS26 XBAFBS25 XBAFBS26
310XBAFBS35 XBAFBS36 XBAFBS35 XBAFBS36
510XBAFBS55 XBAFBS56 XBAFBS55 XBAFBS56
10 10 XBAFBS105 XBAFBS106 XBAFBS105 XBAFBS106
50 10 XBAFBS505 XBAFBS506 XBAFBS505 XBAFBS506
Test adapter 10 XBATSPAI4 XBATSPAI4 XBATSPAI4 XBATSPAI4
2.3 mm diameter test plug XBATSMPS-_ 1XBATSMPS-_ 1XBATSMPS-_ 1XBATSMPS-_ 1
Modular test plug 10 XBATSPS5 XBATSPS6 XBATSPS5 XBATSPS6
Blank marker strip center
and external marking
White 10 XBMZBF5 2XBMZBF6 2XBMZBF5 2XBMZBF6 2
Blank marker strip center
labeling (strip of 10)
White 10 XBMZB5 2XBMZB6 2XBMZB5 2XBMZB6 2
Description XBQT15 XBQT25 XBQT15PE XBQT25PE
Technical Data in Accordance with IEC
Maximum load current in A/cross-section in mm217.5/1.5 24/2.5
Rated surge voltage in kV/contamination class 8/3 8/3 8/3 8/3
Surge voltage category/insulating material group III/I III/I III/I III/I
Connection Cross-Section
Core insulation PVC/PE PVC/PE PVC/PE PVC/PE
Single/multiple/fine strand in mm21.5 2.5 1.5 2.5
Halogen-free in mm21.5 2.5 1.5 2.5
Fine strand/superfine strand in AWG (mm2) 24–16 (0.25–0.34) 20–14 (—) 24–16 (0.25–0.34) 20–14 (—)
Repeated connections minimum 100 x in mm20.25–1.5 0.5–2.5 0.25–1.5 0.5–2.5
Catalog
Number Width Length
Cover
Length
Height for—
35 x 7.5 in 35 x 15 in
XBQT15 0.20 (5.2) 2.31 (58.8) 0.09 (2.2) 1.55 (39.3) 1.84 (46.8)
XBQT25 0.24 (6.2) 2.46 (62.6) 0.09 (2.2) 1.55 (39.3) 1.84 (46.8)
XBQT15PE 0.20 (5.2) 2.31 (58.8) 0.09 (2.2) 1.55 (39.3) 1.84 (46.8)
XBQT25PE 0.24 (6.2) 2.46 (62.6) 0.09 (2.2) 1.55 (39.3) 1.84 (46.8)
V7-T8-70 Volume 7—Logic Control, Operator Interface and Connectivity Solutions CA08100008E—November 2011 www.eaton.com
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8.1
Terminal Blocks, Fuse Blocks and Fuse Holders
IECXB Series
Multi-Conductor
Contents
Description Page
Single Level . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V7-T8-68
Multi-Conductor
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . V7-T8-71
Technical Data and Specifications . . . . . . . . . . V7-T8-72
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . V7-T8-72
Double Level . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V7-T8-73
Fuse Terminal Blocks . . . . . . . . . . . . . . . . . . . . . . . V7-T8-75
Disconnect and Component Terminal Blocks . . . . V7-T8-77
Hybrid Terminal Blocks . . . . . . . . . . . . . . . . . . . . . V7-T8-79
Multi-Conductor
Product Description
The XBQT IDC terminal block
has the fastest connection
time in a compact design.
The space-saving front
connection design offers
additional space for wiring
between the cable ducts.
The double bridge shaft can
accommodate individual
chain bridging and step-down
bridging from other terminal
blocks. The XBQT ground
blocks are the same shape
as the feed-through terminal
blocks with the same wide
range of cross-sections
available. They easily snap
onto the DIN rail to make
a reliable mechanical and
electrical contact that
meets all requirements
of IEC 60-947-7-2.
Product Selection
IDC—Multi-Conductor Terminal Blocks, Three-Wire
IDC—Multi-Conductor Terminal Blocks, Four-Wire
IDC—Multi-Conductor Terminal Blocks, Four-Wire Ground Blocks
Note
1 EU type—examination certificate number: KEMA 05ATEX2157 U (XBQT15), KEMA 05ATEX2160 U (XBQT25).
Terminal
Width
Maximum
Wire Size
Connection Data
in V/A/AWG
EN 50 019 1
in V/A/AWG
UL-cUL Ratings
in V/A/AWG Color
Standard
Pack
Catalog
Number
5.2 mm 16 AWG/1.5 mm2800/17.5/24–16 550/16/24–16 600/10/24–16 Gray 50 XBQT15D12
Blue 50 XBQT15D12BU
6.2 mm 14 AWG/2.5 mm2800/24/20–14 600/15/20–14 Gray 50 XBQT25D12
Blue 50 XBQT25D12BU
Terminal
Width
Maximum
Wire Size
Connection Data
in V/A/AWG
EN 50 019 1
in V/A/AWG
UL-cUL Ratings
in V/A/AWG Color
Standard
Pack
Catalog
Number
5.2 mm 16 AWG/1.5 mm2800/17.5/24–16 550/16/24–16 600/10/24–16 Gray 50 XBQT15D22
Blue 50 XBQT15D22BU
Terminal
Width
Maximum
Wire Size
Connection Data
in V/A/AWG
EN 50 019 1
in V/A/AWG
UL-cUL Ratings
in V/A/AWG Color
Standard
Pack
Catalog
Number
5.2 mm 16 AWG/1.5 mm2—/—/24–16 —/—/24–16 —/—/24–16 Green/Yellow 50 XBQT15D22PE
XBQT25D12
XBQT15D22PE
Volume 7—Logic Control, Operator Interface and Connectivity Solutions CA08100008E—November 2011 www.eaton.com V7-T8-71
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8.1
Terminal Blocks, Fuse Blocks and Fuse Holders
IEC—XB Series
IDC—Multi-Conductor Terminal Blocks, Three-Wire Ground Blocks
Accessories
IDC—Multi-Conductor Terminal Blocks
IDC—Multi-Conductor Terminal/Ground Blocks
Notes
1EU type—examination certificate number: KEMA 05ATEX2157 U (XBQT15PE), KEMA 05ATEX2160 U (XBQT25PE).
2For ordering information, see Page V7-T8-105.
3For information on Printed Marking Tag Options, see Page V7-T8-98.
For additional accessories, see Page V7-T8-90.
Terminal
Width
Maximum
Wire Size
Connection Data
in V/A/AWG
EN 50 019 1
in V/A/AWG
UL-cUL Ratings
in V/A/AWG Color
Standard
Pack
Catalog
Number
5.2 mm 16 AWG/1.5 mm2—/—/24–16 —/—/24–16 —/—/24–16 Green/Yellow 50 XBQT15D12PE
6.2 mm 14 AWG/2.5 mm2—/—/20–14 —/—/20–14 Green/Yellow 50 XBQT25D12PE
Description Color
Number of
Positions
Standard
Pack
XBQT15D12 XBQT25D12 XBQT15D22
Catalog
Number
Catalog
Number
Catalog
Number
End cover Gray 10 XBACQT15D12 XBACQT25D12 XBACQT15D22
End cover segment Gray 10 XBASQT15 XBASQT25 XBASQT15
Partition plate 10 XBATQTD12 XBATQTD12 XBATQTD22
Plug-in bridge—for cross connections
in the terminal center
Red 2 10 XBAFBS25 XBAFBS26 XBAFBS25
310XBAFBS35 XBAFBS36 XBAFBS35
510XBAFBS55 XBAFBS56 XBAFBS55
10 10 XBAFBS105 XBAFBS106 XBAFBS105
50 10 XBAFBS505 XBAFBS506 XBAFBS505
Test adapter 10 XBATSPAI4 XBATSPAI4 XBATSPAI4
2.3 mm diameter test plug XBATSMPS-_ 2XBATSMPS-_ 2XBATSMPS-_ 2
Modular test plug 10 XBATSPS5 XBATSPS6 XBATSPS5
Blank marker strip center
and external marking
White 10 XBMZBF5 3XBMZBF6 3XBMZBF5 3
Blank marker strip center
labeling (strip of 10)
White 10 XBMZB5 3XBMZB6 3XBMZB5 3
Description Color
Number of
Positions
Standard
Pack
XBQT15D12PE XBQT25D12PE XBQT15D22PE
Catalog
Number
Catalog
Number
Catalog
Number
End cover Gray 10 XBACQT15D12 XBACQT25D12 XBACQT15D22
End cover segment Gray 10 XBASQT15 XBASQT25 XBASQT15
Partition plate 10 XBATQTD12 XBATQTD12 XBATQTD22
Plug-in bridge—for cross connections
in the terminal center
Red 2 10 XBAFBS25 XBAFBS26 XBAFBS25
310XBAFBS35 XBAFBS36 XBAFBS35
510XBAFBS55 XBAFBS56 XBAFBS55
10 10 XBAFBS105 XBAFBS106 XBAFBS105
50 10 XBAFBS505 XBAFBS506 XBAFBS505
Test adapter 10 XBATSPAI4 XBATSPAI4 XBATSPAI4
2.3 mm diameter test plug XBATSMPS-_ 2XBATSMPS-_ 2XBATSMPS-_ 2
Modular test plug 10 XBATSPS5 XBATSPS6 XBATSPS5
Blank marker strip center
and external marking
White 10 XBMZBF5 3XBMZBF6 3XBMZBF5 3
Blank marker strip center
labeling (strip of 10)
White 10 XBMZB5 3XBMZB6 3XBMZB5 3
XBQT15D12PE
V7-T8-72 Volume 7—Logic Control, Operator Interface and Connectivity Solutions CA08100008E—November 2011 www.eaton.com
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8.1
Terminal Blocks, Fuse Blocks and Fuse Holders
IECXB Series
Technical Data and Specifications
IDC—Multi-Conductor Terminal Blocks
Dimensions
Approximate Dimensions in Inches (mm)
IDC—Multi-Conductor Terminal Blocks
Description XBQT15D12 XBQT25D12 XBQT15D12PE XBQT25D12PE XBQT15D22 XBQT15D22PE
Technical Data in Accordance with IEC
Maximum load current in A/cross-section in mm217.5/1.5 24/2.5 17.5/1.5
Rated surge voltage in kV/contamination class 8/3 8/3 8/3 8/3 8/3 8/3
Surge voltage category/insulating material group III/I III/I III/I III/I III/I III/I
Connection Cross-Section
Core insulation PVC/PE PVC/PE PVC/PE PVC/PE PVC/PE PVC/PE
Single/multiple/fine strand in mm21.5 2.5 1.5 2.5 1.5 1.5
Halogen-free in mm21.5 2.5 1.5 2.5 1.5 1.5
Fine strand/superfine strand in AWG (mm2) 24–16 (0.25–0.34) 20–14 (—) 24–16 (0.25–0.34) 20–14 (—) 24–16 (0.25–0.34) 24–16 (0.25–0.34)
Repeated connections minimum 100 x in mm20.25–1.5 0.5–2.5 0.25–1.5 0.5–2.5 0.25–1.5 0.25–1.5
Catalog
Number Width Length
Cover
Length
Height for—
35 x 7.5 in 35 x 15 in
XBQT15D12 0.20 (5.2) 3.01 (76.4) 0.09 (2.2) 1.55 (39.3) 1.84 (46.8)
XBQT25D12 0.24 (6.2) 3.25 (82.5) 0.09 (2.2) 1.69 (42.8) 1.98 (50.3)
XBQT15D12PE 0.20 (5.2) 3.01 (76.4) 0.09 (2.2) 1.55 (39.3) 1.84 (46.8)
XBQT25D12PE 0.20 (5.2) 3.25 (82.5) 0.09 (2.2) 1.69 (42.8) 1.98 (50.3)
XBQT15D22 0.20 (5.2) 3.70 (94.0) 0.09 (2.2) 1.55 (39.3) 1.84 (46.8)
XBQT15D22PE 0.20 (5.2) 3.70 (94.0) 0.09 (2.2) 1.55 (39.3) 1.84 (46.8)
Volume 7—Logic Control, Operator Interface and Connectivity Solutions CA08100008E—November 2011 www.eaton.com V7-T8-73
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8.1
Terminal Blocks, Fuse Blocks and Fuse Holders
IEC—XB Series
Double Level
Contents
Description Page
Single Level . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V7-T8-68
Multi-Conductor . . . . . . . . . . . . . . . . . . . . . . . . . . . V7-T8-70
Double Level
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . V7-T8-74
Technical Data and Specifications . . . . . . . . . . V7-T8-74
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . V7-T8-74
Fuse Terminal Blocks . . . . . . . . . . . . . . . . . . . . . . . V7-T8-75
Disconnect and Component Terminal Blocks . . . . V7-T8-77
Hybrid Terminal Blocks . . . . . . . . . . . . . . . . . . . . . V7-T8-79
Double Level
Product Description
The XBQTT IDC terminal
block has the fastest
connection time in a compact
design. The space-saving
front connection design
offers additional space for
wiring between the cable
ducts. The double bridge
shaft, found in each level, can
accommodate individual
chain bridging and step-down
bridging from other terminal
blocks. The XBQTT ground
blocks are the same shape as
the feed-through terminal
blocks with the same wide
range of cross-sections
available. They easily snap
onto the DIN rail to make a
reliable mechanical and
electrical contact that
meets all requirements of
IEC 60-947-7-2.
Product Selection
IDC—Double Level Terminal Blocks
IDC—Double Level Ground Blocks
Note
1 EU type—examination certificate number: KEMA 05ATEX2157 U (XBQT15), KEMA 05ATEX2160 U (XBQT25).
Terminal
Width
Maximum
Wire Size
Connection Data
in V/A/AWG
EN 50 019 1
in V/A/AWG
UL-cUL Ratings
in V/A/AWG Color
Standard
Pack
Catalog
Number
5.2 mm 16 AWG/1.5 mm2800/17.5/24–16 420/15/24–16 600/10/24–16 Gray 50 XBQTT15
Blue 50 XBQTT15BU
Terminal
Width
Maximum
Wire Size
Connection Data
in V/A/AWG
EN 50 019 1
in V/A/AWG
UL-cUL Ratings
in V/A/AWG Color
Standard
Pack
Catalog
Number
6.2 mm 14 AWG/2.5 mm2—/—/24–16 —/—/24–16 —/—/24–16 Green/Yellow 50 XBQTT15PE
XBQTT15
XBQTT15PE
V7-T8-74 Volume 7—Logic Control, Operator Interface and Connectivity Solutions CA08100008E—November 2011 www.eaton.com
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8.1
Terminal Blocks, Fuse Blocks and Fuse Holders
IECXB Series
Accessories
IDC—Double Level Terminal/Ground Blocks
Technical Data and Specifications
IDC—Double Level Terminal/Ground Blocks
Dimensions
Approximate Dimensions in Inches (mm)
IDC—Double Level Terminal/Ground Blocks
Notes
1For ordering information, see Page V7-T8-105.
2For information on Printed Marking Tag Options, see Page V7-T8-98.
For additional accessories, see Page V7-T8-90.
Description Color
Number of
Positions
Standard
Pack
XBQTT15 XBQTT15PE
Catalog
Number
Catalog
Number
End cover Gray 10 XBACQTT15 XBACQTT15
Partition plate 10 XBATQTT15 XBATQTT15
Plug-in bridge—for cross connections
in the terminal center
Red 2 10 XBAFBS25 XBAFBS25
310 XBAFBS35 XBAFBS35
510 XBAFBS55 XBAFBS55
10 10 XBAFBS105 XBAFBS105
20 10 XBAFBS505 XBAFBS505
Test adapter 10 XBATSPAI4 XBATSPAI4
2.3 mm diameter test plug XBATSMPS-_ 1XBATSMPS-_ 1
Modular test plug 10 XBATSPS5 XBATSPS5
Blank marker strip White 10 XBMZBF5 2XBMZBF5 2
Description XBQTT15 XBQTT15PE
Technical Data in Accordance with IEC
Maximum load current in A/cross-section in mm217.5/1.5
Rated surge voltage in kV/contamination class 6/3 6/3
Surge voltage category/insulating material group III/I III/I
Connection Cross-Section
Core insulation PVC/PE PVC/PE
Single/multiple/fine strand in mm21.5 1.5
Halogen-free in mm21.5 1.5
Fine strand/superfine strand in AWG (mm2) 24–16 (0.25–0.34) 24–16 (0.25–0.34)
Repeated connections minimum 100 x in mm20.25–1.5 0.25–1.5
Catalog
Number Width Length
Cover
Length
Height for—
35 x 7.5 in 35 x 15 in
XBQTT15 0.20 (5.2) 3.92 (99.6) 0.09 (2.2) 1.96 (49.9) 2.26 (57.4)
XBQTT15PE 0.20 (5.2) 3.92 (99.6) 0.09 (2.2) 1.96 (49.9) 2.26 (57.4)
Volume 7—Logic Control, Operator Interface and Connectivity Solutions CA08100008E—November 2011 www.eaton.com V7-T8-75
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8.1
Terminal Blocks, Fuse Blocks and Fuse Holders
IEC—XB Series
Fuse Terminal Blocks
Contents
Description Page
Single Level . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V7-T8-68
Multi-Conductor . . . . . . . . . . . . . . . . . . . . . . . . . . . V7-T8-70
Double Level . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V7-T8-73
Fuse Terminal Blocks
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . V7-T8-76
Technical Data and Specifications . . . . . . . . . . V7-T8-76
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . V7-T8-76
Disconnect and Component Terminal Blocks . . . . V7-T8-77
Hybrid Terminal Blocks . . . . . . . . . . . . . . . . . . . . . V7-T8-79
Fuse Terminal Blocks
Product Description
The XBQT lever-type fuse
terminal blocks perform two
main functions. It is a carrier
for a 5 x 20 mm cartridge
fuse insert and can also
allow for potential distribution
via the double bridge shaft.
This means that two
potentials can be carried
separately alongside each
other. Versions with light
indication (AC and DC
voltage) are available to
signal a triggered fuse.
Product Selection
IDC—Fuse Terminal Blocks
Note
1 As disconnect terminal block, 400V; as fuse terminal blocks 250V.
Terminal
Width
Maximum
Wire Size
Connection Data
in V/A/AWG
UL-cUL Ratings
in V/A/AWG Color
Standard
Pack
Catalog
Number
IDC Fuse Terminal Blocks
6.2 mm 14 AWG/2.5 mm21/6.3/20–14 300/15/20–14 Black 50 XBQT25FBE
IDC Fuse Terminal Blocks with LED 12–30V, 1–2.5 mA
6.2 mm 14 AWG/2.5 mm21/6.3/20–14 300/15/20–14 Black 50 XBQT25FBEL24
IDC Fuse Terminal Blocks with LED 30–60V, 0.8–2.0 mA
6.2 mm 14 AWG/2.5 mm21/6.3/20–14 300/15/20–14 Black 50 XBQT25FBEL60
IDC Fuse Terminal Blocks with LED 110–250V, 0.5–2.5 mA
6.2 mm 14 AWG/2.5 mm21/6.3/20–14 300/15/20–14 Black 50 XBQT25FBEL250
XBQT25FB
V7-T8-76 Volume 7—Logic Control, Operator Interface and Connectivity Solutions CA08100008E—November 2011 www.eaton.com
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8.1
Terminal Blocks, Fuse Blocks and Fuse Holders
IECXB Series
Accessories
IDC—Fuse Terminal Blocks
Technical Data and Specifications
IDC—Fuse Terminal Blocks
Dimensions
Approximate Dimensions in Inches (mm)
IDC—Fuse Terminal Blocks
Notes
1For ordering information, see Page V7-T8-105.
2For information on Printed Marking Tag Options, see Page V7-T8-98.
For additional accessories, see Page V7-T8-90.
Description Color
Number of
Positions
Standard
Pack
XBQT25FBE
Catalog
Number
End cover Gray 10 XBACQT25D12
Partition plate 10 XBATQTD12
Plug-in bridge—for cross connections
in the terminal center
Red 2 10 XBAFBS26
310XBAFBS36
510XBAFBS56
10 10 XBAFBS106
Test adapter 10 XBATSPAI4
2.3 mm diameter test plug XBATSMPS-_ 1
Modular test plug 10 XBATSPS5
Blank marker strip center
and external marking
White 10 XBMZBF6 2
Blank marker strip lever labeling White 10 XBMZB5 2
Blank marker strip center
labeling (strip of 10)
White 10 XBMZB6 2
Description XBQT25FBE
Technical Data in Accordance with IEC
Maximum load current in A/cross-section in mm26.3/2.5
Rated surge voltage in kV/contamination class 4/3
Surge voltage category/insulating material group III/I
Connection Cross-Section
Core insulation PVC/PE
Single/multiple/fine strand in mm22.5
Halogen-free in mm22.5
Fine strand/superfine strand in AWG (mm2) 24–14 (—)
Repeated connections minimum 100 x in mm20.5–2.5
Catalog
Number Width Length
Cover
Length
Height for—
35 x 7.5 in 35 x 15 in
XBQT25FBE 0.24 (6.2) 3.25 (82.5) 0.09 (2.2) 1.69 (42.8) 1.98 (50.3)
Volume 7—Logic Control, Operator Interface and Connectivity Solutions CA08100008E—November 2011 www.eaton.com V7-T8-77
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8.1
Terminal Blocks, Fuse Blocks and Fuse Holders
IEC—XB Series
Disconnect and Component Terminal Blocks
Contents
Description Page
Single Level . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V7-T8-68
Multi-Conductor . . . . . . . . . . . . . . . . . . . . . . . . . . . V7-T8-70
Double Level . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V7-T8-73
Fuse Terminal Blocks . . . . . . . . . . . . . . . . . . . . . . . V7-T8-75
Disconnect and Component Terminal Blocks
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . V7-T8-78
Technical Data and Specifications . . . . . . . . . . V7-T8-78
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . V7-T8-78
Hybrid Terminal Blocks . . . . . . . . . . . . . . . . . . . . . V7-T8-79
Disconnect and Component Terminal Blocks
Product Description
The XB Series includes
application specific terminal
blocks like disconnect blocks.
The knife disconnect terminal
blocks (XBQT15MT) has a
fitted knife. The XBQT15TG
can accommodate component
plugs for resistors or
capacitors and fuse plugs
for 5 x 20 mm fuses with or
without a light indicator for
signaling a triggered fuse.
Both terminal blocks have
three bridge shafts—two in
the standard positions and
one on the other side of the
disconnect point.
Product Selection
IDC—Disconnect and Component Terminal Blocks
Terminal
Width
Maximum
Wire Size
Connection Data
in V/A/AWG
UL-cUL Ratings
in V/A/AWG
UL-cUL Ratings
for Disconnect
in V/A/AWG
UL-cUL Ratings
for Disconnect
with Test Sockets
in V/A/AWG Color
Standard
Pack
Catalog
Number
Knife Disconnect
5.2 mm 16 AWG/1.5 mm2400/16/24–16 600/10/24–16 Gray 50 XBQT15MT
Component Disconnect
5.2 mm 16 AWG/1.5 mm2400/16/24–16 600/10/24–16 Gray 50 XBQT15TG
6.2 mm 14 AWG/2.5 mm2400/16/20–14 300/10/20–14 Gray 50 XBQT25TG
Component Plug
6.2 mm 10 AWG/4 mm2500/16/26–10 600/16/26–10 300/16/26–10 Gray 10 XBPCO
Fuse Plug
6.2 mm 10 AWG/4 mm2500/16/26–10 600/16/26–10 300/16/26–10 Black 10 XBPFU
Fuse Plug with Light Indicator for 12–30V, 1–2.5 mA
6.2 mm 10 AWG/4 mm2500/16/26–10 600/16/26–10 300/16/26–10 Black 10 XBPFUL24
Fuse Plug with Light Indicator for 110–250V, 0.5–2.5 mA
6.2 mm 10 AWG/4 mm2500/16/26–10 600/16/26–10 300/16/26–10 Black 10 XBPFUL250
XBQT15MT
Knife Disconnect
V7-T8-78 Volume 7—Logic Control, Operator Interface and Connectivity Solutions CA08100008E—November 2011 www.eaton.com
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8.1
Terminal Blocks, Fuse Blocks and Fuse Holders
IECXB Series
Accessories
IDC—Disconnect and Component Terminal Blocks
Technical Data and Specifications
IDC—Disconnect and Component Terminal Blocks
Dimensions
Approximate Dimensions in Inches (mm)
IDC—Disconnect and Component Terminal Blocks
Notes
1For ordering information, see Page V7-T8-105.
2For information on Printed Marking Tag Options, see Page V7-T8-98.
For additional accessories, see Page V7-T8-90.
Description Color
Number of
Positions
Standard
Pack
XBQT15MT XBQT15TG XBQT25TG
Catalog
Number
Catalog
Number
Catalog
Number
End cover Gray 10 XBACQT15D12 XBACQT15D12 XBACQT25D12
End cover segment Gray 10 XBASQT15 XBASQT15 XBASQT25
Partition plate 10 XBATQTD12 XBATQTD12 XBATQTD12
Plug-in bridge Red 2 10 XBAFBS25 XBAFBS25 XBAFBS26
310XBAFBS35 XBAFBS35 XBAFBS36
510XBAFBS55 XBAFBS55 XBAFBS56
10 10 XBAFBS105 XBAFBS105 XBAFBS106
Test adapter 10 XBATSPAI4 XBATSPAI4 XBATSPAI4
2.3 mm diameter test plug XBATSMPS-_ 1XBATSMPS-_ 1XBATSMPS-_ 1
Modular test plug 10 XBATSPS5 XBATSPS5 XBATSPS5
Blank marker strip center and
external marking
White 10 XBMZBF5 2XBMZBF5 2XBMZBF6 2
Blank marker strip center labeling
(strip of 10)
White 10 XBMZB5 2XBMZB5 2XBMZB6 2
Description XBQT15MT XBQT15TG XBQT25TG
Technical Data in Accordance with IEC
Maximum load current in A/cross-section in mm216/1.5 16/1.5 16/2.5
Rated surge voltage in kV/contamination class 6/3 6/3 6/3
Surge voltage category/insulating material group III/I III/I III/I
Connection Cross-Section
Core insulation PVC/PE PVC/PE PVC/PE
Single/multiple/fine strand in mm21.5 1.5 2.5
Halogen-free in mm21.5 1.5 2.5
Fine strand/superfine strand in AWG (mm2) 24–16 (0.25–0.34) 24–16 (0.25–0.34) 20–14 (—)
Repeated connections minimum 100 x in mm20.25–1.5 0.25–1.5 0.5–2.5
Catalog
Number Width Length
Cover
Length
Height for—
35 x 7.5 in 35 x 15 in
XBQT15MT 0.20 (5.2) 3.01 (76.4) 0.09 (2.2) 1.55 (39.3) 1.84 (46.8)
XBQT15TG 0.20 (5.2) 3.01 (76.4) 0.09 (2.2) 1.55 (39.3) 1.84 (46.8)
XBQT25TG 0.24 (6.2) 3.25 (82.5) 0.09 (2.2) 1.69 (42.8) 1.98 (50.3)
Volume 7—Logic Control, Operator Interface and Connectivity Solutions CA08100008E—November 2011 www.eaton.com V7-T8-79
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8.1
Terminal Blocks, Fuse Blocks and Fuse Holders
IEC—XB Series
Hybrid Terminal Blocks
Contents
Description Page
Single Level . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V7-T8-68
Multi-Conductor . . . . . . . . . . . . . . . . . . . . . . . . . . . V7-T8-70
Double Level . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V7-T8-73
Fuse Terminal Blocks . . . . . . . . . . . . . . . . . . . . . . . V7-T8-75
Disconnect and Component Terminal Blocks . . . . V7-T8-77
Hybrid Terminal Blocks
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . V7-T8-80
Technical Data and Specifications . . . . . . . . . . V7-T8-81
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . V7-T8-81
Hybrid Terminal Blocks
Product Description
The XBQT hybrid terminal
blocks offer the best of both
worlds. One side offers the
time-saving advantage of our
insulation displacement
connection technology,
while the other side offers a
universal screw connection.
Use the IDC side on the
internal (factory) control
cabinet side and the screw
connection on the end
customer (field) side. Ground
terminal blocks of the same
shape are also available
Product Selection
IDC—Hybrid Terminal Blocks, Single Level
IDC—Hybrid Terminal Blocks, Three-Wire
IDC—Hybrid Terminal/Ground Blocks
Terminal
Width
Maximum
Wire Size
IEC Screw
Connection
in V/A/AWG
IEC IDC
Connection
in V/A/AWG
UL-cUL Screw
Connection
in V/A/AWG
UL-cUL IDC
Connection
in V/A/AWG Color
Standard
Pack
Catalog
Number
5.2 mm 12 AWG/2.5 mm2800/17.5/26–12 800/17.5/24–16 600/10/26–12 600/10/24–16 Gray 50 XBQU15
6.2 mm 10 AWG/4 mm2800/24/26–10 800/24/20–14 600/15/26–10 600/15/20–14 Gray 50 XBQU25
Terminal
Width
Maximum
Wire Size
IEC Screw
Connection
in V/A/AWG
IEC IDC
Connection
in V/A/AWG
UL-cUL Screw
Connection
in V/A/AWG
UL-cUL IDC
Connection
in V/A/AWG Color
Standard
Pack
Catalog
Number
5.2 mm 12 AWG/2.5 mm2800/17.5/26–12 800/17.5/24–16 800/10/26–12 800/10/24–16 Gray 50 XBQU15D12
6.2 mm 10 AWG/4 mm2800/24/26–10 800/24/20–14 600/15/26–10 600/15/20–14 Gray 50 XBQU25D12
Terminal
Width
Maximum
Wire Size
IEC Screw
Connection
in V/A/AWG
IEC IDC
Connection
in V/A/AWG
UL-cUL Screw
Connection
in V/A/AWG
UL-cUL IDC
Connection
in V/A/AWG Color
Standard
Pack
Catalog
Number
5.2 mm 12 AWG/2.5 mm2—/—/26–12 —/—/24–16 —/—/26–12 —/—/24–16 Gray 50 XBQU15PE
6.2 mm 10 AWG/4 mm2—/—/26–10 —/—/20–14 —/—/26–10 —/—/20–14 Gray 50 XBQU25PE
XBQU25
XBQU15D12
XBQU25PE
V7-T8-80 Volume 7—Logic Control, Operator Interface and Connectivity Solutions CA08100008E—November 2011 www.eaton.com
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8.1
Terminal Blocks, Fuse Blocks and Fuse Holders
IECXB Series
Accessories
IDC—Hybrid Terminal Blocks
IDC—Hybrid Terminal/Ground Blocks
Notes
1For ordering information, see Page V7-T8-105.
2For information on Printed Marking Tag Options, see Page V7-T8-98.
For additional accessories, see Page V7-T8-90.
Description Color
Number of
Positions
Standard
Pack
XBQU15 XBQU25 XBQU15D12 XBQU25D12
Catalog
Number
Catalog
Number
Catalog
Number
Catalog
Number
End cover Gray 10 XBACQU15 XBACQU25 XBACQU15D12 XBACQU25D12
End segment Gray 10 XBASQT15 XBASQT25
Partition plate 10 XBATQT25 XBATQT25 XBATQTD12 XBATQTD12
Plug-in bridge—for cross
connections in the bridge shaft
Red 2 10 XBAFBS25 XBAFBS26 XBAFBS25 XBAFBS26
310XBAFBS35 XBAFBS36 XBAFBS35 XBAFBS36
510XBAFBS55 XBAFBS56 XBAFBS55 XBAFBS56
10 10 XBAFBS105 XBAFBS106 XBAFBS105 XBAFBS106
50 10 XBAFBS505 XBAFBS506 XBAFBS505 XBAFBS506
Test adapter 10 XBATSPAI4 XBATSPAI4 XBATSPAI4 XBATSPAI4
2.3 mm diameter test plug XBATSMPS-_ 1XBATSMPS-_ 1XBATSMPS-_ 1XBATSMPS-_ 1
Modular test plug 10 XBATSPS5 XBATSPS6 XBATSPS5 XBATSPS6
Blank marker strip center
and external marking
White 10 XBMZBF5 2XBMZBF6 2XBMZBF5 2XBMZBF6 2
Blank marker strip center
labeling (strip of 10)
XBMZB5 2XBMZB6 2XBMZB5 2XBMZB6 2
Description Color
Number of
Positions
Standard
Pack
XBQU15PE XBQU25PE
Catalog
Number
Catalog
Number
End cover Gray 10 XBACQU15 XBACQU25
Partition plate 10 XBATQT25 XBATQT25
Plug-in bridge—for cross
connections in the bridge shaft
Red 2 10 XBAFBS25 XBAFBS26
310XBAFBS35 XBAFBS36
510XBAFBS55 XBAFBS56
10 10 XBAFBS105 XBAFBS106
50 10 XBAFBS505 XBAFBS506
Test adapter 10 XBATSPAI4 XBATSPAI4
2.3 mm diameter test plug XBATSMPS-_ 1XBATSMPS-_ 1
Modular test plug 10 XBATSPS5 XBATSPS6
Blank marker strip center
and external marking
White 10 XBMZBF5 2XBMZBF6 2
Blank marker strip center
labeling (strip of 10)
XBMZB5 2XBMZB6 2
Volume 7—Logic Control, Operator Interface and Connectivity Solutions CA08100008E—November 2011 www.eaton.com V7-T8-81
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8.1
Terminal Blocks, Fuse Blocks and Fuse Holders
IEC—XB Series
Technical Data and Specifications
Screw Connection Single Level—Through-Feed
Dimensions
Approximate Dimensions in Inches (mm)
Screw Connection Single Level—Through-Feed
Description XBQU15 XBQU25 XBQU15PE XBQU25PE XBQU15D12 XBQU25D12
Technical Data in Accordance with IEC
Maximum load current in A/cross-section in mm217.5/1.5 24/2.5 17.5/1.5 24/2.5
Rated surge voltage in kV/contamination class 8/3 8/3 8/3 8/3 8/3 8/3
Surge voltage category/insulating material group III/I III/I III/I III/I III/I III/I
Connection Cross-Section
Core insulation PVC/PE PVC/PE PVC/PE PVC/PE PVC/PE PVC/PE
Single/multiple/fine strand in mm21.5 2.5 1.5 2.5 1.5 2.5
Halogen-free in mm21.5 2.5 1.5 2.5 1.5 2.5
Fine strand/superfine strand in AWG (mm2) 24–16 (0.25–0.34) 20–14 (—) 24–16 (0.25–0.34) 20–14 (—) 24–16 (0.25–0.34) 20–14 (—)
Repeated connections minimum 100 x in mm20.25–1.5 0.5–2.5 0.25–1.5 0.5–2.5 0.25–1.5 0.5–2.5
Connection Capacity—Screw Connection
Stranded with ferrule/with ferrule and
plastic sleeve in mm2
0.25–2.5/0.25–2.5 0.25–4/0.25–4 0.25–2.5/0.25–2.5 0.25–4/0.25–4 0.25–2.5/0.25–2.5 0.25–4/0.25–4
Multi-Conductor Connection
(same cross-section)
Solid/stranded in mm20.14–1.5/0.14–1.5 0.14–1.5/0.14–1.5 0.14–1.5/0.14–1.5 0.14–1.5/0.14–1.5 0.14–1.5/0.14–1.5 0.14–1.5/0.14–1.5
Stranded with ferrules without plastic sleeve in mm20.25–1.5 0.25–1.5 0.25–1.5 0.25–1.5 0.25–1.5 0.25–1.5
Stranded with twin ferrule with plastic sleeve in mm20.5–1.5 0.5–2.5 0.5–1.5 0.5–2.5 0.5–1.5 0.5–2.5
Stripping length in inches (mm) 0.35 (9) 0.35 (9) 0.35 (9) 0.35 (9) 0.35 (9) 0.35 (9)
Thread M3 M3 M3 M3 M3 M3
Torque in in-lb (Nm) 5.3–7.1 (0.6–0.8) 5.3–7.1 (0.6–0.8) 5.3–7.1 (0.6–0.8) 5.3–7.1 (0.6–0.8) 5.3–7.1 (0.6–0.8) 5.3–7.1 (0.6–0.8)
Catalog
Number Width Length
Cover
Width
Height for—
35 x 7.5 in 35 x 15 in
XBQU15 0.20 (5.2) 2.31 (58.8) 0.09 (2.2) 1.69 (42.8) 1.98 (50.3)
XBQU25 0.24 (6.2) 2.46 (62.6) 0.09 (2.2) 1.69 (42.8) 1.98 (50.3)
XBQU15PE 0.20 (5.2) 2.31 (58.8) 0.09 (2.2) 1.69 (42.8) 1.98 (50.3)
XBQU25PE 0.24 (6.2) 2.46 (62.6) 0.09 (2.2) 1.69 (42.8) 1.98 (50.3)
XBQU15D12 0.20 (5.2) 3.01 (76.4) 0.09 (2.2) 1.69 (42.8) 1.98 (50.3)
XBQU25D12 0.24 (6.2) 3.25 (82.5) 0.09 (2.2) 1.69 (42.8) 1.98 (50.3)
V7-T8-82 Volume 7—Logic Control, Operator Interface and Connectivity Solutions CA08100008E—November 2011 www.eaton.com
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8.1
Terminal Blocks, Fuse Blocks and Fuse Holders
IECXB Series
Miniature Circuit Breakers
Contents
Description Page
Miniature Circuit Breakers
Circuit Breakers. . . . . . . . . . . . . . . . . . . . . . . . . V7-T8-83
Flat-Type Fuse Terminal Blocks . . . . . . . . . . . . . V7-T8-86
Spring Cage Fuse Terminal Blocks . . . . . . . . . . V7-T8-88
Miniature Circuit Breakers Overview
Product Description
The new XB Series thermal
miniature circuit breaker
offers convenient overload
protection. This space-saving
single-pole circuit breaker,
available up to 10 amps,
can be inserted into a screw
connection fuse terminal
block, XBUK6FSI, or a spring
cage fuse terminal block,
XBPT4FSI, which is available
with or without light indication.
The XBATCP combines the
reclosing capability of a circuit
breaker with the overload
protection of a fuse. The
integrated switching function
makes it possible to switch
the circuit breaker back on
immediately, guaranteeing
system availability. The
device can also be used for
switching purposes, as an
ON/OFF switch. The Plug-in
design allows for quick and
efficient replacement.
Standards and Certifications
UL and cUL recognized
UL 1077—File No. E301915
CE approved
Volume 7—Logic Control, Operator Interface and Connectivity Solutions CA08100008E—November 2011 www.eaton.com V7-T8-83
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8.1
Terminal Blocks, Fuse Blocks and Fuse Holders
IEC—XB Series
Circuit Breakers
Contents
Description Page
Circuit Breakers
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . V7-T8-84
Technical Data and Specifications . . . . . . . . . . V7-T8-84
Time/Current Curve . . . . . . . . . . . . . . . . . . . . . V7-T8-85
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . V7-T8-85
Flat-Type Fuse Terminal Blocks . . . . . . . . . . . . . . . V7-T8-86
Spring Cage Fuse Terminal Blocks . . . . . . . . . . . . . V7-T8-88
Circuit Breakers
Product Description
The thermal miniature circuit
breaker can be switched back
on again, has a compact
design, and is available
in 10 finely graded steps
for nominal currents from
0.1 to 10A.
Product Selection
Thermal Miniature Circuit Breaker
Connection Data
in Vac/Vdc
Nominal
Current Color
Standard
Pack
Catalog
Number
250/65 0.1A Black 20 XBATCPT
0.25A Black 20 XBATCPQ
0.5A Black 20 XBATCPH
1.0A Black 20 XBATCP1
2.0A Black 20 XBATCP2
3.0A Black 20 XBATCP3
4.0A Black 20 XBATCP4
6.0A Black 20 XBATCP6
8.0A Black 20 XBATCP8
10.0A Black 20 XBATCP10
XBAT
V7-T8-84 Volume 7—Logic Control, Operator Interface and Connectivity Solutions CA08100008E—November 2011 www.eaton.com
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8.1
Terminal Blocks, Fuse Blocks and Fuse Holders
IECXB Series
Accessories
Thermal Miniature Circuit Breaker
Technical Data and Specifications
Thermal Miniature Circuit Breaker
Nominal Currents and Internal Resistances
Note
1For information on Printed Marking Tag Options, see Page V7-T8-98.
Description Color
Number of
Positions
Standard
Pack
XBAT
Catalog
Number
Blank marker strip White 10 XBMZBF5 1
Flat type terminal blocks XBUK6FSI
XBUK6FSIL12
XBUK6FSIL24
XBPT4FSI
XBPT4FSIL12
XBPT4FSIL24
Description XBAT
Technical Data in Accordance with IEC
Nominal voltage in Vac/Vdc 250/65
Nominal current in A 0.25–10
Ambient temperature –4 to 140°F (–20 to 60°C)
Maximum Power Dissipation
Rated surge voltage in kV/contamination class 2.5/2
Surge voltage category/insulating material group III/I
Switching Capacity
Cycles with 1 x IN (low-induction) 6000
Cycles with 1 x IN (induction) 3000
Cycles with 2 x IN (induction) 500
Switching Capacity I CN
For nominal currents of 0.25–4A/6–10A 6 x IN/8 x IN
Switching capacity (UL 1077) 250 Vac/65 Vdc 2000/200
Nominal
Current (A)
Internal
Resistance (3/4)
0.25 14
0.5 3.4
1.0 0.9
2.0 0.25
3.0 0.11
4.0 0.07
6.0 <0.05
8.0 <0.05
10.0 <0.05
Volume 7—Logic Control, Operator Interface and Connectivity Solutions CA08100008E—November 2011 www.eaton.com V7-T8-85
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8.1
Terminal Blocks, Fuse Blocks and Fuse Holders
IEC—XB Series
Time/Current Curve
Total Switch-Off Period for Nominal Current, 73.4°F (23°C)
Note: When mounted in rows, the nominal current of
the devices can only be transmitted at 80% or must
be correspondingly over-dimensioned.
Temperature Factor
Dimensions
Approximate Dimensions in Inches (mm)
XBUK6FSI with XBAT XBPT4FSI with XBAT
Ambient Temperature Temperature Factor
–4°F (–20°C) 0.76
14°F (–10°C) 0.84
32°F (0°C) 0.91
73.4°F (23°C) 1.00
104°F (40°C) 1.08
122°F (50°C) 1.16
140°F (60°C) 1.24
0.96
(24.4)
2.52
(64) 0.32
(8.2)
1.73
(44)
1.75
(44.5)
1.93
(49)
2.03
(51.5)
0.96
(24.4)
3.39
(86.2)
3.41
(86.5) 0.32
(8.2)
1.72
(43.7)
V7-T8-86 Volume 7—Logic Control, Operator Interface and Connectivity Solutions CA08100008E—November 2011 www.eaton.com
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8.1
Terminal Blocks, Fuse Blocks and Fuse Holders
IECXB Series
Flat-Type Fuse Terminal Blocks
Contents
Description Page
Circuit Breakers . . . . . . . . . . . . . . . . . . . . . . . . . . . V7-T8-83
Flat-Type Fuse Terminal Blocks
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . V7-T8-86
Technical Data and Specifications . . . . . . . . . . V7-T8-87
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . V7-T8-87
Spring Cage Fuse Terminal Blocks . . . . . . . . . . . . V7-T8-88
Flat-Type Fuse Terminal Blocks
Product Description
The fuse terminal blocks can
be used as a basic terminal
blocks for the XBAT overload
miniature circuit breaker, see
Page V7-T8-83.
Product Selection
Screw Connection Flat-Type Fuse Terminal Blocks
Accessories
Flat-Type Fuse Terminal Blocks
Note
1For information on Printed Marking Tag Options, see Page V7-T8-98.
Terminal
Width
Maximum
Wire Size
Connection Data
in V/A/AWG
UL-cUL Ratings
in V/A/AWG Color
Standard
Pack
Catalog
Number
Flat-Type Fuse Terminal Block
8.2 mm 8 AWG/6 mm2250/—/24–8 300/30/26–8 Black 50 XBUK6FSI
Flat-Type Fuse Terminal Block with LED, Red 12 Vdc, 2.0 mA
8.2 mm 8 AWG/6 mm2250/—/24–8 300/30/26–8 Black 50 XBUK6FSIL12
Flat-Type Fuse Terminal Block with LED, Red 24 Vdc, 2.0 mA
8.2 mm 8 AWG/6 mm2250/—/24–8 300/30/26–8 Black 50 XBUK6FSIL24
Description Color
Number of
Positions
Standard
Pack
XBUK6FSI XBUK6FSIL_
Catalog
Number
Catalog
Number
Blank marker strip White 10 XBMZB8 1XBMZB8 1
XBUK6FSI
Volume 7—Logic Control, Operator Interface and Connectivity Solutions CA08100008E—November 2011 www.eaton.com V7-T8-87
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8.1
Terminal Blocks, Fuse Blocks and Fuse Holders
IEC—XB Series
Technical Data and Specifications
Flat-Type Fuse Terminal Blocks
Dimensions
Approximate Dimensions in Inches (mm)
Flat-Type Fuse Terminal Blocks
Description XBUK6FSI XBUK6FSIL_
Technical Data in Accordance with IEC
Fuse type ISO C C
Maximum current with single arrangement in A 30 30
Maximum Power Dissipation
Rated surge voltage in kV/contamination class 4/3 4/3
Surge voltage category/insulating material group III/I III/I
Connection Capacity
Stranded with ferrule with plastic sleeve in mm20.25–4 0.25–4
Stranded with ferrule without plastic sleeve in mm20.25–6 0.25–6
Stranded with twin ferrule with plastic sleeve in mm2——
Multi-Conductor Connection
(same cross-section)
Solid/stranded in mm20.2–2.5/0.2–2.5 0.2–2.5/0.2–2.5
Stranded with ferrules without plastic sleeve in mm20.25–2.5 0.25–2.5
Stranded with twin ferrule with plastic sleeve in mm20.5–4.0 0.5–4.0
Stripping length in inches (mm) 0.39 (10) 0.39 (10)
Thread M4 M4
Torque in in-lb (Nm) 13.3–14.2 (1.5–1.6) 13.3–14.2 (1.5–1.6)
Catalog
Number Width Length
Height for—
32 in 35 x 7.5 in 35 x 15 in
XBUK6FSI 0.32 (8.2) 2.91 (74.0) 2.24 (57.0) 2.05 (52.0) 2.34 (59.5)
XBUK6FSIL12 0.32 (8.2) 2.91 (74.0) 2.24 (57.0) 2.05 (52.0) 2.34 (59.5)
XBUK6FSIL24 0.32 (8.2) 2.91 (74.0) 2.24 (57.0) 2.05 (52.0) 2.34 (59.5)
V7-T8-88 Volume 7—Logic Control, Operator Interface and Connectivity Solutions CA08100008E—November 2011 www.eaton.com
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8.1
Terminal Blocks, Fuse Blocks and Fuse Holders
IECXB Series
Spring Cage Fuse Terminal Blocks
Contents
Description Page
Circuit Breakers . . . . . . . . . . . . . . . . . . . . . . . . . . . V7-T8-83
Flat-Type Fuse Terminal Blocks . . . . . . . . . . . . . . . V7-T8-86
Spring Cage Fuse Terminal Blocks
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . V7-T8-88
Technical Data and Specifications . . . . . . . . . . V7-T8-89
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . V7-T8-89
Spring Cage Fuse Terminal Blocks
Product Description
Flat-type fuses or the XBAT
miniature circuit breaker (see
Page V7-T8-83) can be used
as the fuse element in these
XBPT
Spring Cage Fuse Terminal
Blocks. Terminal blocks with
a light indicator are available
for quick error diagnosis.
Product Selection
Spring Cage Fuse Terminal Blocks
Accessories
Flat-Type Fuse Terminal Blocks
Notes
1For ordering information, see Page V7-T8-105.
2For information on Printed Marking Tag Options, see Page V7-T8-98.
Terminal
Width
Maximum
Wire Size
Connection Data
in V/A/AWG
UL-cUL Ratings
in V/A/AWG Color
Standard
Pack
Catalog
Number
Spring Cage Fuse Terminal Block
8.2 mm 10 AWG/4 mm2400/30/28–10 300/30/24–10 Black 50 XBPT4FSI
Spring Cage Fuse Terminal Block with LED, Red 12 Vdc, 2.0 mA
8.2 mm 10 AWG/4 mm2400/30/28–10 300/30/24–10 Black 50 XBPT4FSIL12
Spring Cage Fuse Terminal Block with LED, Red 24 Vdc, 2.0 mA
8.2 mm 10 AWG/4 mm2400/30/28–10 300/30/24–10 Black 50 XBPT4FSIL24
Description Color
Number of
Positions
Standard
Pack
XBPT4FSI XBPT4FSIL_
Catalog
Number
Catalog
Number
Test adapter 10 XBATSPAI4 XBATSPAI4
2.3 mm diameter test plug XBATSMPS-_ 1XBATSMPS-_ 1
Modular test plug 10 XBATSPS8 XBATSPS8
Blank marker strip center and external marking White 10 XBMZBF8 2XBMZBF8 2
Blank marker strip center labeling (strip of 10) White 10 XBMZB8 2XBMZB8 2
XBPT4FSI
Volume 7—Logic Control, Operator Interface and Connectivity Solutions CA08100008E—November 2011 www.eaton.com V7-T8-89
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8.1
Terminal Blocks, Fuse Blocks and Fuse Holders
IEC—XB Series
Technical Data and Specifications
Flat-Type Fuse Terminal Blocks
Dimensions
Approximate Dimensions in Inches (mm)
Flat-Type Fuse Terminal Blocks
Description XBPT4FSI XBPT4FSIL_
Technical Data in Accordance with IEC
Fuse type ISO C C
Maximum current with single arrangement in A 30 30
Maximum Power Dissipation
Rated surge voltage in kV/contamination class 6/3 6/3
Surge voltage category/insulating material group III/I III/I
Connection Capacity
Stranded with ferrule with plastic sleeve in mm20.25–4 0.25–4
Stranded with ferrule without plastic sleeve in mm20.25–4 0.25–4
Stranded with twin ferrule with plastic sleeve in mm20.5 0.5
Stripping length in inches (mm) 0.39 (10) 0.39 (10)
Catalog
Number Width Length
Height for—
35 x 7.5 in 35 x 15 in
XBPT4FSI 0.32 (8.2) 3.41 (86.5) 1.71 (43.5) 2.01 (51.0)
XBPT4FSIL12 0.32 (8.2) 3.41 (86.5) 1.71 (43.5) 2.01 (51.0)
XBPT4FSIL24 0.32 (8.2) 3.41 (86.5) 1.71 (43.5) 2.01 (51.0)
V7-T8-90 Volume 7—Logic Control, Operator Interface and Connectivity Solutions CA08100008E—November 2011 www.eaton.com
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8.1
Terminal Blocks, Fuse Blocks and Fuse Holders
IECXB Series
XB Series Accessories
Contents
Description Page
XB Series Accessories
End Stops . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V7-T8-91
DIN Rails . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V7-T8-92
Angled Mounting Brackets . . . . . . . . . . . . . . . . V7-T8-93
Ferrules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V7-T8-94
Hand Tools . . . . . . . . . . . . . . . . . . . . . . . . . . . . V7-T8-97
Marking Accessories . . . . . . . . . . . . . . . . . . . . V7-T8-98
Testing Accessories . . . . . . . . . . . . . . . . . . . . . V7-T8-105
Separating Plates, Covers and Bridges . . . . . . V7-T8-105
XB Series Accessories Overview
End Stops
The end stop provides an
anchor point at each end of
the rail assembly by attaching
directly to the DIN rail. A wide
range of end stop options are
available, including those that
mount with one or multiple
screws and those that do not
require screws for mounting.
End stops also have a
location for marking material
to be placed.
DIN Rail
Eaton offers ways for time-
saving and secure mounting
of components needed for
electrical connections. DIN
rail provides the basis for the
inner design of the control
cabinet and ensures a firm
hold of the rail-mountable
components. Eaton offers a
wide range of standard DIN
rails sizes and materials,
solid or slotted. Or, contact
us about custom lengths of
pre-cut rail or ordering pre-
drilled rail. The DIN rails are
designed in accordance with
the European standard
EN 60715.
Angled Mounting Brackets
Angled mounting brackets
are used to mount DIN rail at
a more accessible angle for
wiring and troubleshooting.
Ferrules
Ferrules are available with or
without an insulating sleeve.
The plastic insulating sleeve
simplifies the fitting of the
conductor and the color
indicates the size of the
cross-section. The closer the
connections are, the more
reliable the insulation is and
the less likely the wires are to
splice. Twin ferrules are also
available allowing two wires
to be easily compressed in
one ferrule. Chain bridging,
frequently used in industry,
becomes easier with twin
ferrules.
Hand Tools
Eaton offers an array of hand
tools to make it easier to work
with our terminal blocks. The
XBTCUTSTP tool is
recommended for cutting and
stripping PVC insulated wires.
The ergonomically shaped
crimping pliers, XBTCRMP66,
result in fatigue-free work by
spreading the manual force
equally between the six jaws.
The XBTDVR screwdrivers
have a rotating cap that
prevents user discomfort
even at high torques and
allows rapid rotation. The
ergonomically shaped handle
further aids the user’s
comfort. The blade is made
from CVM steel, hardened
and chrome-plated.
Marking Accessories
The marking system provides
logical and clear identification
of the modular terminal
blocks and interface modules.
The blank marker strip is
designed for marking terminal
blocks, equipment and
smaller modules with marker
grooves. The marker strip is
available in all common
pitches in printed and
unprinted versions.
Testing Accessories
The range of test accessories
available includes different
test plugs, so that an
optimum solution can be
realized for every application.
In addition to pre-assembled
test plugs, plugs are also
available that can be
configured individually to
form test adapters.
Volume 7—Logic Control, Operator Interface and Connectivity Solutions CA08100008E—November 2011 www.eaton.com V7-T8-91
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8.1
Terminal Blocks, Fuse Blocks and Fuse Holders
IEC—XB Series
End Stops
Product Selection
Snap-On End Stop (15 mm)
Snap-On End Stop (35 mm)
Snap-on end stops for 35 mm
and 15 mm DIN rails can
be fitted with blank marker
strips and adjustable terminal
strip markers, parking facility
for bridges and testing
accessories.
Dimensions
Approximate Dimensions in Inches (mm)
Snap-On End Stop
XBAES35N XBAES15N
Universal End Stop
XBAES35T XBAES35C
XBAES35AL
XBAES35C
XBAES35T
Standard
Pack
Catalog
Number
50 XBAES15N
Standard
Pack
Catalog
Number
50 XBAES35N
1.38
(35)
0.20
(5)
1.91
(48.5)
0.89
(22.6)
0.87
(22)
0.20
(5.2)
0.98
(24.8)
1.39
(35.3)
0.37 (9.5)
1.99
(50.5)
1.29
(32.8)
0.37 (9.5)
1.91
(48.6)
Universal End Stop (15 mm)
Universal End Stop (35 mm)
Screwed on, labeling with
blank marker strips and
terminal strip markers.
Aluminum End
Snaps on, for end support of
50–240 mm terminal blocks,
labeling with XBMZB10.
Cross-Reference of Terminal Blocks Marking, End Stops
Aluminum End Stop
XBAES35AL
XBAES15C
Standard
Pack
Catalog
Number
50 XBAES15C
Standard
Pack
Catalog
Number
50 XBAES35T
50 XBAES35C
Standard
Pack
Catalog
Number
10 XBAES35AL
Catalog
Number XBMKLM2 XBMGLMA XBMUBE
XBAES35N X—
XBAES35T —X X
1.73
(44)
0.39
(10)
2.32
(59)
0.71
(18)
0.24 (6.1)
0.83
(21.2)
V7-T8-92 Volume 7—Logic Control, Operator Interface and Connectivity Solutions CA08100008E—November 2011 www.eaton.com
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8.1
Terminal Blocks, Fuse Blocks and Fuse Holders
IECXB Series
DIN Rails
Product Selection
Perforated and unperforated
DIN rails in accordance with
E 60715.
Features
High dimensional accuracy
Restricted tolerances
Double surface tempering,
galvanized and chromated
All 2m in length
Customization available
35 x 7.5 mm x 2m
35 x 15 mm x 2m
15 x 5.5 mm x 2m
Aluminum DIN Rails
(Perforated)
Dimensions
Approximate Dimensions in Inches (mm)
35 x 7.5 mm DIN Rail 35 x 15 mm DIN Rail 15 x 5.5 mm x 2m DIN Rail XBANS35PL Raised Rail
Standard
Pack
Catalog
Number
Slotted
25 XBANS3575P
Solid
25 XBANS3575U
Standard
Pack
Catalog
Number
Slotted
25 XBANS3515P
Solid
25 XBANS3515U
Standard
Pack
Catalog
Number
25 XBANS15P
Standard
Pack
Catalog
Number
35/7.5/2m
25 XBANS3575PL
35/58/2m
6XBANS35PL
0.24
(6.2)
1.06 (27)
0.03 (0.8)
Rad.
0.03 (0.8)
Rad.
1.38 (35)
0.98
(25)
0.30
(7.5)
0.04
(1)
0.59
(15)
0.05 (1.25)
Rad.
0.05 (1.25)
Rad.
0.24
(6.2)
0.98
(25)
0.59
(15)
0.03
(0.8)
15°
1.38 (35)
0.59
(15)
0.06
(1.5)
1.06 (27)
0.02 (0.5)
Rad.
0.01 (0.2)
Rad.
0.17
(4.2)
0.59
(15)
0.41
(10.5)
0.22
(5.5)
0.04
(1)
0.48
(12.2)
0.79
(20)
5.00
(127)
1.38
(35)
0.08
(2)
0.95
(24)
1.02
(26)
1.02
(26)
2.28 (58)
1.89 (48)
Volume 7—Logic Control, Operator Interface and Connectivity Solutions CA08100008E—November 2011 www.eaton.com V7-T8-93
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8.1
Terminal Blocks, Fuse Blocks and Fuse Holders
IEC—XB Series
Angled Mounting Brackets
Product Selection
The angled brackets enable
the DIN rail to be mounted
with a spacing or at an angle
of 30°.
Features
For mounting DIN rail at
30° angle
For use with M6 screw
Chromated steel
Provides better visibility
Angled Mounting Bracket
Dimensions
Approximate Dimensions in Inches (mm)
XBANBGS XBANBGSH
Standard
Pack
Catalog
Number
Height Inches (mm)
1.39 (35.4)
10 XBANBGS
Height Inches (mm)
1.81 (46)
10 XBANBGSH
3.43
(87)
0.08
(2)
2.54
(64.5)
0.61
(15.4)
0.65
(16.5)
1.39
(35.4) 0.79
(20)
0.28 (7)
Dia.
M6
Screw
30°
3.31
(84)
0.08
(2)
30°
2.44
(62)
0.54
(13.7)
0.55
(14)
1.81
(46) 0.79
(20)
0.28 (7)
Dia.
M6
Screw
V7-T8-94 Volume 7—Logic Control, Operator Interface and Connectivity Solutions CA08100008E—November 2011 www.eaton.com
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8.1
Terminal Blocks, Fuse Blocks and Fuse Holders
IECXB Series
Ferrules
Product Selection
Ferrules are offered in two
basic designs—an insulated
style available in models for
wire sizes 20 through 4 AWG
and a non-insulated type
available in models for wire
sizes 22 through 6 AWG.
Note: UL Ratings do not typically
pertain to the use of Ferrules—
Ferrules are covered under
DIN VDE 0611.
Insulated
Tube: soft electrolytic copper (E-CU), tin plated
Plastic sleeve: polypropylene
Long-term temperature 105°C
Short-term temperature 120°C
Insulated Ferrules
Wire Size
AWG (mm2) Color 1
Standard
Pack 2
Catalog
Number
20 (0.5) White 100 XBAF1
18 (0.75) Gray 100 XBAF3
18 (1) Red 100 XBAF4
16 (1.5) Black 100 XBAF6
14 (2.5) Blue 100 XBAF9
14 (2.5) Blue 100 XBAF10
12 (4) Gray 100 XBAF11
12 (4) Gray 100 XBAF12
10 (6) Yellow 100 XBAF13
10 (6) Yellow 100 XBAF14
8 (10) Red 100 XBAF15
8 (10) Red 100 XBAF16
6 (16) Blue 100 XBAF17
6 (16) Blue 100 XBAF18
4 (25) Yellow 50 XBAF19
XBAF1
Non-Insulated
Tube: soft electrolytic copper (E-CU), tin plated
Non-Insulated Ferrules
Special Applications
The twin ferrules allow two
conductors to be compressed
practically in one ferrule.
The colored coding of the
various cross sections
corresponds to DIN 46 228-4.
Non-Insulated Twin Ferrules
Notes
1The colored coding of the various cross-sections corresponds to DIN 46 228-4.
2Standard pack is the number of ferrules that come in each bag. Must order in
multiples of standard pack.
Example: XBAF1—an order for 200 pieces will receive 2 bags of ferrules,
each with 100 pieces.
Wire Size
AWG (mm2)
Standard
Pack 2
Catalog
Number
20 (0.5) 100 XBAF20
18 (0.75) 100 XBAF21
18 (1) 100 XBAF23
16 (1.5) 100 XBAF24
14 (2.5) 100 XBAF25
12 (4) 100 XBAF26
10 (6) 100 XBAF27
8 (10) 100 XBAF28
6 (16) 100 XBAF29
XBAF20
Wire Size
AWG (mm2) Color 1
Standard
Pack 2
Catalog
Number
20 (0.5) White 100 XBAFT1
18 (0.75) Gray 100 XBAFT3
18 (1) Red 100 XBAFT4
16 (1.5) Black 100 XBAFT6
14 (2.5) Blue 100 XBAFT9
12 (4) Gray 100 XBAFT11
10 (6) Yellow 100 XBAFT13
8 (10) Red 100 XBAFT15
6 (16) Blue 50 XBAFT18
XBAFT1
Volume 7—Logic Control, Operator Interface and Connectivity Solutions CA08100008E—November 2011 www.eaton.com V7-T8-95
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8.1
Terminal Blocks, Fuse Blocks and Fuse Holders
IEC—XB Series
Dimensions
Approximate Dimensions in Inches (mm)
Ferrules with Insulating Collar
Ferrules without Insulating Collar
Catalog
Number
Approximate Dimensions
D1 D2 L1 L2 S1 S2
XBAF1 0.04 (1.1) 0.10 (2.5) 0.55 (14.0) 0.31 (8.0) 0.006 (0.15) 0.010 (0.25)
XBAF3 0.05 (1.3) 0.11 (2.8) 0.55 (14.0) 0.31 (8.0) 0.006 (0.15) 0.010 (0.25)
XBAF4 0.06 (1.5) 0.12 (3.0) 0.55 (14.0) 0.31 (8.0) 0.006 (0.15) 0.012 (0.30)
XBAF6 0.07 (1.8) 0.13 (3.4) 0.55 (14.0) 0.31 (8.0) 0.006 (0.15) 0.012 (0.30)
XBAF9 0.09 (2.3) 0.17 (4.2) 0.55 (14.0) 0.31 (8.0) 0.006 (0.15) 0.012 (0.30)
XBAF10 0.09 (2.3) 0.17 (4.2) 0.94 (24.0) 0.71 (18.0) 0.006 (0.15) 0.012 (0.30)
XBAF11 0.11 (2.8) 0.19 (4.8) 0.67 (17.0) 0.39 (10.0) 0.008 (0.20) 0.012 (0.30)
XBAF12 0.11 (2.8) 0.19 (4.8) 1.02 (26.0) 0.71 (18.0) 0.008 (0.20) 0.012 (0.30)
XBAF13 0.14 (3.5) 0.24 (6.2) 0.79 (20.0) 0.47 (12.0) 0.008 (0.20) 0.012 (0.30)
XBAF14 0.14 (3.5) 0.24 (6.2) 1.02 (26.0) 0.71 (18.0) 0.008 (0.20) 0.012 (0.30)
XBAF15 0.18 (4.6) 0.30 (7.5) 0.87 (22.0) 0.47 (12.0) 0.008 (0.20) 0.012 (0.30)
XBAF16 0.18 (4.6) 0.30 (7.5) 1.10 (28.0) 0.71 (18.0) 0.008 (0.20) 0.012 (0.30)
XBAF17 0.23 (5.8) 0.35 (8.8) 0.94 (24.0) 0.47 (12.0) 0.008 (0.20) 0.016 (0.40)
XBAF18 0.23 (5.8) 0.35 (8.8) 1.10 (28.0) 0.71 (18.0) 0.008 (0.20) 0.016 (0.40)
XBAF19 0.29 (7.3) 0.43 (11.0) 1.26 (32.0) 0.71 (18.0) 0.008 (0.20) 0.020 (0.50)
Catalog
Number
Approximate Dimensions
D1 D2 L1 L2 S
XBAF20 0.04 (1.0) 0.08 (2.1) 0.24 (6.0) 0.21 (5.3) 0.006 (0.15)
XBAF21 0.05 (1.2) 0.09 (2.3) 0.24 (6.0) 0.21 (5.3) 0.006 (0.15)
XBAF23 0.06 (1.4) 0.10 (2.5) 0.24 (6.0) 0.21 (5.3) 0.006 (0.15)
XBAF24 0.07 (1.7) 0.11 (2.8) 0.28 (7.0) 0.24 (6.0) 0.006 (0.15)
XBAF25 0.09 (2.2) 0.13 (3.4) 0.28 (7.0) 0.24 (6.0) 0.006 (0.15)
XBAF26 0.11 (2.8) 0.16 (4.0) 0.35 (9.0) 0.31 (8.0) 0.008 (0.20)
XBAF27 0.14 (3.5) 0.19 (4.7) 0.47 (12.0) 0.35 (9.0) 0.008 (0.20)
XBAF28 0.18 (4.5) 0.23 (5.8) 0.47 (12.0) 0.43 (10.8) 0.008 (0.20)
XBAF29 0.23 (5.8) 0.30 (7.5) 0.47 (12.0) 0.41 (10.5) 0.008 (0.20)
D2
S2
L2
L1
S1 D1
D2
D1
L2
L1
S
V7-T8-96 Volume 7—Logic Control, Operator Interface and Connectivity Solutions CA08100008E—November 2011 www.eaton.com
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8.1
Terminal Blocks, Fuse Blocks and Fuse Holders
IECXB Series
Approximate Dimensions in Inches (mm)
Twin Ferrules
Catalog
Number
Approximate Dimensions
D1 D2 L1 L2 S1 S2
XBAFT1 0.06 (1.5) 0.10 (2.5) 0.59 (15.0) 0.31 (8.0) 0.006 (0.15) 0.010 (0.25)
XBAFT3 0.07 (1.8) 0.11 (2.8) 0.59 (15.0) 0.31 (8.0) 0.006 (0.15) 0.010 (0.25)
XBAFT4 0.08 (2.1) 0.13 (3.4) 0.59 (15.0) 0.31 (8.0) 0.006 (0.15) 0.012 (0.30)
XBAFT6 0.09 (2.3) 0.14 (3.6) 0.63 (16.0) 0.31 (8.0) 0.006 (0.15) 0.012 (0.30)
XBAFT9 0.11 (2.9) 0.17 (4.2) 0.73 (18.5) 0.39 (10.0) 0.008 (0.20) 0.012 (0.30)
XBAFT11 0.15 (3.8) 0.19 (4.9) 0.91 (23.0) 0.47 (12.0) 0.008 (0.20) 0.012 (0.30)
XBAFT13 0.19 (4.9) 0.23 (5.9) 0.98 (25.0) 0.55 (14.0) 0.008 (0.20) 0.016 (0.40)
XBAFT15 0.26 (6.5) 0.28 (7.2) 1.02 (26.0) 0.55 (14.0) 0.008 (0.20) 0.016 (0.40)
XBAFT18 0.33 (8.5) 0.35 (8.8) 1.22 (31.0) 0.63 (16.0) 0.008 (0.20) 0.020 (0.50)
D2
S2
L2
L1
D1
S1
Volume 7—Logic Control, Operator Interface and Connectivity Solutions CA08100008E—November 2011 www.eaton.com V7-T8-97
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8.1
Terminal Blocks, Fuse Blocks and Fuse Holders
IEC—XB Series
Hand Tools
Stripping Tools
Product Selection
Stripping Tools
Technical Data and Specifications
Conductor/Cable Stripping Range
Dimensions
Approximate Dimensions in Inches (mm)
Stripping Tools
Crimping Pliers
The crimping pliers deform the ferrules hexagonally.
For 0.25–6 mm2 ferrules in accordance with
DIN 46 228-1: 1992-08 and DIN 46 228-4: 1990-09.
Product Selection
Crimping Pliers
Technical Data and Specifications
Areas of Application
Dimensions
Approximate Dimensions in Inches (mm)
Crimping Pliers
Slotted Screwdrivers
The crimping pliers deform the ferrules hexagonally.
For 0.25–6 mm2 ferrules in accordance with
DIN 46 228-1: 1992-08 and DIN 46 228-4: 1990-09.
Product Selection
Slotted Screwdrivers
Standard
Pack
Catalog
Number
1XBTCUTSTP
Description Specification
Conductor/cable 0.2–6 mm2/24–10 AWG
Wire cutter 6 mm2/10 AWG
Length
Stripping
Length
Weight
In lbs (g)
8.07 (205) Up to 18 mm 0.44 (200)
Standard
Pack
Catalog
Number
1XBTCRMP66
Description Specification
Conductor 0.25–6 mm2
Conductor 23–10 AWG
Length
Weight
In lbs (g)
6.85 (175) 0.79 (360)
Standard
Pack
Catalog
Number
3.5 mm
1XBTDVR35
4.0 mm
1XBTDVR40
V7-T8-98 Volume 7—Logic Control, Operator Interface and Connectivity Solutions CA08100008E—November 2011 www.eaton.com
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8.1
Terminal Blocks, Fuse Blocks and Fuse Holders
IECXB Series
Marking Accessories
Printed Marking Tag Options
Horizontally Printed Marking Tags and Marking Directions
Marking Tags for 5.2 mm Wide Terminal Blocks Marking Tags for 6.2 mm Wide Terminal Blocks
Note
1For text printed horizontally, change “V” in catalog number to “H.”
12345678910
Marking Direction: Horizontal
1
2
3
4
5
6
7
8
9
10
Marking Direction: Vertical
Standard
Pack
Number
Sequence
Catalog
Number
ZB5 Tags Vertically Numbered
10 1–10 1XBMZB5V/1
10 11–20 XBMZB5V/11
10 21–30 XBMZB5V/21
10 31–40 XBMZB5V/31
10 41–50 XBMZB5V/41
10 51–60 XBMZB5V/51
10 61–70 XBMZB5V/61
10 71–80 XBMZB5V/71
10 81–90 XBMZB5V/81
10 91–100 XBMZB5V/91
ZBF5 Tags Vertically Numbered
10 1–10 1XBMZBF5V/1
10 11–20 XBMZBF5V/11
10 21–30 XBMZBF5V/21
10 31–40 XBMZBF5V/31
10 41–50 XBMZBF5V/41
10 51–60 XBMZBF5V/51
10 61–70 XBMZBF5V/61
10 71–80 XBMZBF5V/71
10 81–90 XBMZBF5V/81
10 91–100 XBMZBF5V/91
Standard
Pack
Number
Sequence
Catalog
Number
ZB6 Tags Vertically Numbered
10 1–10 1XBMZB6V/1
10 11–20 XBMZB6V/11
10 21–30 XBMZB6V/21
10 31–40 XBMZB6V/31
10 41–50 XBMZB6V/41
10 51–60 XBMZB6V/51
10 61–70 XBMZB6V/61
10 71–80 XBMZB6V/71
10 81–90 XBMZB6V/81
10 91–100 XBMZB6V/91
ZBF6 Tags Vertically Numbered
10 1–10 1XBMZBF6V/1
10 11–20 XBMZBF6V/11
10 21–30 XBMZBF6V/21
10 31–40 XBMZBF6V/31
10 41–50 XBMZBF6V/41
10 51–60 XBMZBF6V/51
10 61–70 XBMZBF6V/61
10 71–80 XBMZBF6V/71
10 81–90 XBMZBF6V/81
10 91–100 XBMZBF6V/91
Volume 7—Logic Control, Operator Interface and Connectivity Solutions CA08100008E—November 2011 www.eaton.com V7-T8-99
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8.1
Terminal Blocks, Fuse Blocks and Fuse Holders
IEC—XB Series
Marking Tags for 8.2 mm Wide Terminal Blocks
Marking Tags for 10.2 mm Wide Terminal Blocks
Marking Tags for 12 mm Wide Terminal Blocks
Marking Tags for 16 mm Wide Terminal Blocks
Note
1For text printed horizontally, change “V” in catalog number to “H.”
Standard
Pack
Number
Sequence
Catalog
Number
ZB8 Tags Vertically Numbered
10 1–10 1XBMZB8V/1
10 11–20 XBMZB8V/11
10 21–30 XBMZB8V/21
10 31–40 XBMZB8V/31
10 41–50 XBMZB8V/41
10 51–60 XBMZB6V/51
10 61–70 XBMZB8V/61
10 71–80 XBMZB8V/71
10 81–90 XBMZB8V/81
10 91–100 XBMZB8V/91
ZBF8 Tags Vertically Numbered
10 1–10 1XBMZBF8V/1
10 11–20 XBMZBF8V/11
10 21–30 XBMZBF8V/21
10 31–40 XBMZBF8V/31
10 41–50 XBMZBF8V/41
10 51–60 XBMZBF8V/51
10 61–70 XBMZBF8V/61
10 71–80 XBMZBF8V/71
10 81–90 XBMZBF8V/81
10 91–100 XBMZBF8V/91
Standard
Pack
Number
Sequence
Catalog
Number
ZB10 Tags Vertically Numbered
10 1–10 1XBMZB10V/1
10 11–20 XBMZB10V/11
10 21–30 XBMZB10V/21
ZBF10 Tags Vertically Numbered
10 1–10 1XBMZBF10V/1
10 11–20 XBMZBF10V/11
10 21–30 XBMZBF10V/21
Standard
Pack
Number
Sequence
Catalog
Number
ZB12 Tags Vertically Numbered
10 1–10 1XBMZB12V/1
10 11–20 XBMZB12V/11
10 21–30 XBMZB12V/21
ZBF12 Tags Vertically Numbered
10 1–10 1XBMZBF12V/1
10 11–20 XBMZBF12V/11
10 21–30 XBMZBF12V/21
Standard
Pack
Number
Sequence
Catalog
Number
ZB15 Tags Vertically Numbered
10 1–10 1XBMZB15V/1
10 11–20 XBMZB15V/11
10 21–30 XBMZB15V/21
ZBF15 Tags Vertically Numbered
10 1–10 1XBMZBF15V/1
10 11–20 XBMZBF15V/11
10 21–30 XBMZBF15V/21
V7-T8-100 Volume 7—Logic Control, Operator Interface and Connectivity Solutions CA08100008E—November 2011 www.eaton.com
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8.1
Terminal Blocks, Fuse Blocks and Fuse Holders
IECXB Series
Pre-Printed Marking Tags
Terminal Blocks Marking Tags
The tags are made of white self-extinguishing polyamide 6.6 and the imprint is hot stamped
with rubproof black ink.
White marking strip
available preprinted. Strip
covers 10 terminals.
Marking 1 10, 11–20, up
to 991–999. Contact Eaton
for more options.
XBMZB5 or XBMZBF5
for terminal blocks
5.2 mm wide
XBMZB6 or XBMZBF6
for terminal blocks
6.2 mm wide
XBMZB8 or XBMZBF8
for terminal blocks
8.2 mm wide
XBMZB10 or XBMZBF10
for terminal blocks
10.2 mm wide
XBMZB12 or XBMZBF12
for terminal blocks
12 mm wide
XBMZB15 or XBMZBF15
for terminal blocks
16 mm wide
Marking Tag Sizes
Note: Marking Tag Sizes are for all catalog numbers starting with given prefix, EXCEPT FUSE TERMINAL Blocks.
Proper Marking Tag Size
Notes
1For center labeling.
2For external labeling.
3For center and outside labeling.
4For lever labeling.
5Two (2) XBMZB10 tags fit in one (1) XBMKLMZ.
XBMZB5 XBMZBF5 XBMZB6 XBMZBF6 XBMZB8 XBMZBF8 XBMZB10 XBMZBF10 XBMZB12 XBMZBF12 XBMZB15 XBMZBF15 XBMSSZB
XBUT25 XBPT25 2XBUT4 XBPT4 2XBUT6 XBPT6 2XBUT10 XBPT10 2XBPT16 1XBPT16 2XBUT35 XBPT35 2XBMKLMZ
XBUT4FBE 1XBPTT25 XBUTT4 XBPTT4 XBPT6 1XBPT4FBN 2XBUT16 XBPT35 1——
XBUT6FBN 1XBPTK XB3UKA XBPT4FBE 2XBUK6 XBPT4FSI 2XBTK
XBPT25 1XBPU25 2XB3UKF XBQT25 3XBPT4FSI 1 XBUK50
XBPT4FBE 1XBAP … XBUT4FBE 2XBQT25FBE 3 XBUK150——————
XBPU25 1XBQT15 3XBUT6FBN 2XBQU25 3 XBUK95
XBQT15 1XBQTT15 XBUK10 XBPT10 1——————
XBQT25FBE 4XBQU15 3XBUKK4 XBMKLMZ 5——————
XBQU15 1XBMPK15 XBPT4 1 ———
XBMUK25 XBMPKK15 XBPT4FBN 1 ———
XBATCP… XBQT25 1 ———
XBQT25FBE 1 ———
XBQU25 1 ———
XBMUK4
Volume 7—Logic Control, Operator Interface and Connectivity Solutions CA08100008E—November 2011 www.eaton.com V7-T8-101
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8.1
Terminal Blocks, Fuse Blocks and Fuse Holders
IEC—XB Series
Marker Strips and Sheets (for use with XBAPLT2006K1 plotter)
The XB Series marking system provides logical and clear
identification of the modular terminal blocks and interface
modules.
Product Selection
Marker Strips (Strip of 10)
Label Sheets for Laser Printers
The XBM labels have been specially developed for laser printers
and have considerable advantages:
Can be printed on all commercially available laser printers
Or can use plotter or pen for printing
Good adhesive properties
A4 size
XBMKL25X12WH designed to fit XBGBS2512 group marker
XBMLMAL447 is perforated for terminal strip marker
XBMGLMA and is 44 x 7 mm
Marker Sheets (Strip of 10)
Product Selection
Label Sheets
Note
1All markers are strips of 10, except XBMZB15, which is a strip of 5.
Terminal
Width
Standard
Pack
Catalog
Number
Blank Strips
5.2 mm 10 XBMZB5
6.2 mm 10 XBMZB6
8.2 mm 10 XBMZB8
10.2 mm 10 XBMZB10
12 mm 10 XBMZB12
16 mm 10 XBMZB15 1
Flat Strips
5.2 mm 10 XBMZBF5
6.2 mm 10 XBMZBF6
8.2 mm 10 XBMZBF8
10.2 mm 10 XBMZBF10
12 mm 10 XBMZBF12
16 mm 10 XBMZBF15
XBMZB_
Terminal
Width) Color
Stnd.
Pack
Catalog
Number
Marker Sheets (10 rows of 12)
5.2 mm White 50 XBMPZB5
Blue 50 XBMPZB5BU
Red 50 XBMPZB5RD
Yellow 50 XBMPZB5YE
Green 50 XBMPZB5GN
Marker Sheets (10 rows of 10)
6.2 mm White 50 XBMPZB6
Blue 50 XBMPZB6BU
Red 50 XBMPZB6RD
Yellow 50 XBMPZB6YE
Green 50 XBMPZB6GN
Flat Marker Sheets (10 rows of 10)
5.2 mm White 10 XBMPZBF5
Orange 10 XBMPZBF5OG
White 10 XBMPZBF6
Orange 10 XBMPZBF6OG
White 10 XBMPZBF8
Standard
Pack
Catalog
Number
10 XBMKL25X12WH
10 XBMLMAL447
XBMPZB_
XBMPZBF_
XBM_
V7-T8-102 Volume 7—Logic Control, Operator Interface and Connectivity Solutions CA08100008E—November 2011 www.eaton.com
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8.1
Terminal Blocks, Fuse Blocks and Fuse Holders
IECXB Series
Terminal Block Group Marking
Terminal block groups are marked using marking labels that are
snapped into the marker strip groove of the terminal blocks. The
group is marked using either labels or insert markers.
Product Selection
Terminal Block Group Marking 1
Terminal Strip Markers
Adjustable height for end bracket labeling.
Product Selection
Terminal Strip Markers 1
Terminal Strip Marker Carriers
For labeling terminal groups, for mounting on DIN rail. Lettering
field is 40 x 17 mm.
Product Selection
Terminal Strip Marker Carriers
Insert Markers for Laser Printers
One sheet = 56 labels. Lettering field is 40 x 17 mm.
Product Selection
Insert Markers for XBMUBE(D)
Refillable Marker Pen
Refillable marker pen for manual labeling, line thickness
0.35 mm.
Product Selection
Terminal Strip Markers 1
Non-Refillable Marker Pen
For manual labeling, line thickness 0.5 mm.
Product Selection
Non-Refillable Marker Pen
Note
1 See Page V7-T8-101 for insert labels.
Standard
Pack
Catalog
Number
100 XBGBS2512
Standard
Pack
Catalog
Number
20 x 8 mm Wide
10 XBMKLM2
44 x 7 mm Wide
10 XBMGLMA
Standard
Pack
Catalog
Number
10 XBMUBE
10 XBMUBED
XBGBS2512
XBM_
XBMUB_
Standard
Pack
Catalog
Number
10 XBMUBEL4017
Standard
Pack
Catalog
Number
Pen
1XBMXPEN
Ink Cartridge
1XBMINK
Standard
Pack
Catalog
Number
1XBMBSTIFT
XBMUBEL4017
XBMXPEN
XBMUBE
Volume 7—Logic Control, Operator Interface and Connectivity Solutions CA08100008E—November 2011 www.eaton.com V7-T8-103
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8.1
Terminal Blocks, Fuse Blocks and Fuse Holders
IEC—XB Series
Marking Plotter
The automatic Prepare Pen
function ensures optimum
marking results right from the
first character.
Pens can remain in the pen
station even for prolonged
intervals without drying out.
Custom Marking Tag System
This plotter system uses
Windows®-based software to
interface with a PC, allowing
custom printing on standard
terminal blocks marking tags.
These standard marking tags
provide circuit identification
for Eaton DIN rail mount
terminal blocks.
Features
Enter tag text directly into
EMARK software program
or import file from
AutoCAD or Excel®
Selectable font sizes, types
and colors including
common symbols for
circuit identification
(ground, ~ etc.)
Various text formatting
options including copy,
paste, increment functions,
text alignment, etc.
Durable templates allow
printing of four different tag
sizes at the same time
Automatic prepare pen
function for optimum
results
Technical Data and Specifications
Marking Plotter
Dimensions
Approximate Dimensions in Inches (mm)
Marking Plotter
Description Specification
Plotter
Plotter type Flatbed plotter
Maximum plotting surface 440 mm x 296 mm
Maximum material height 10.5 mm
Maximum plotting speed 40 cm/sec
Pen station Four depots with double sealing
Drive Two-phase impulse-driven motor
Interfaces Parallel (Centronics)/USB Level 1.1
Electronics
Command language Based on HP-GL 7475A
Data buffer 16 MB
Addressable resolution 0.01 mm
Repeat accuracy 0.05 mm
Repeat accuracy on pen change 0.05 mm with optimum pen
Power Supply
Power supply Via separate power supply unit with
exchangeable mains feeder cable
Power supply unit input voltage 100–240 Vac/50–60 Hz
Power supply unit input current (maximum) 0.3A at 230V~
Power supply unit output voltage 24 Vdc
Power supply unit output current (maximum) 1.4A
Environmental conditions
Operation 50° to 95°F (10° to 35°C)
35% to 75% relative humidity
Storage 14° to 122°F (–10° to 50°C)
10% to 90% relative humidity
Approx. Weight
L W H In Lbs (kg)
25.98 (660) 17.32 (440) 4.92 (125) 18 (8)
V7-T8-104 Volume 7—Logic Control, Operator Interface and Connectivity Solutions CA08100008E—November 2011 www.eaton.com
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8.1
Terminal Blocks, Fuse Blocks and Fuse Holders
IECXB Series
Marking Plotter
EMARK Software
Eaton’s EMARK software makes labeling your terminal blocks quick and simple.
You can import your data from ECHART, any other CAD/CAE program, or enter
text directly into EMARK. The software allows marking tags to be printed on the
PLT2006 plotter in a professional manner.
Note
1 Plotter kit includes PLT2006 plotter system with EMARK software and user manual, starter ink and cleaning
sets, and templates for marking all XBMZB and XBMZBF tags.
Description
Standard
Pack
Catalog
Number
Plotter kit 11XBAPLT2006K1
Pen station sealing set 1 XBMP1PENDEPOT
Plotter pen preparation plate 1 XBMP1PREPLATES
Template for marker strips 1 XBMP1MZB
Template for flat marker strips 1 XBMP1MZBF
Template for XBMPZB marker sheets 1 XBMP1MPZB
Template for XBMPZBF marker sheets 1 XBMP1MPZBF
Template for Weidmuller multicard sheet 1 XBMP1MCSF46
Template for Weidmuller multicard sheet universal 1 XBMP1MCU
Template for Entrelec sheets 1 XBMP1MRC
0.25 mm disposal pen 1 XBMDPEN25R
0.35 mm disposal pen 1 XBMDPEN35R
0.25 mm pen 1 XBMPEN25
0.35 mm pen 1 XBMPEN35
Ink Cartridge 2 XBMINK
Pen cleaning set 1 XBMRSET
Cleaning cartridges 2 XBMRMEKFC2
Volume 7—Logic Control, Operator Interface and Connectivity Solutions CA08100008E—November 2011 www.eaton.com V7-T8-105
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8.1
Terminal Blocks, Fuse Blocks and Fuse Holders
IEC—XB Series
Testing Accessories
Test Adapter
For 4 mm diameter test plug and 4 mm diameter safety test
plug. Makes contact in the bridge shaft.
Product Selection
Te s t A d a p t e r
Modular Test Plugs
For individual assembly of test plug strips.
Product Selection
Modular Test Plugs
Test Plugs
Consisting of metal part for socket hole and insulating sleeve.
Product Selection
Test Plugs
Separating Plates, Covers and Bridges
End Cover
Used to cover an open end of terminal block
when changing sizes within an assembly and/
or for last terminal block in a row.
Partition Plate
Protrudes over the terminal block and is used
to increase electrical clearance between
terminals. Also provides visual indications of
the functions of terminal blocks. For
example, terminal blocks between two
partition plates may provide an exact location
for test points.
End Cover Segment
Covers protruding terminal block segments
of three- and four-wire terminal blocks when
next to a two wire blocks. This ensures that
all is touch-proof and saves space over using
a standard end cover.
Jumper/Bridge
Provides the ability to electrically connect
terminal blocks. Non-adjacent blocks may be
bridged by snapping off the contact tabs of
the standard bridge. The reducing bridge
permits simple connection of terminal blocks
with different nominal cross-sections.
Note
See these accessories as listed with terminal blocks for more information.
Standard
Pack
Catalog
Number
1XBATSPAI4
Standard
Pack
Catalog
Number
Test Plugs
10 XBATSPS5
10 XBATSPS6
10 XBATSPS8
Spacer Plate
10 XBATSDPPS5
10 XBATSDPPS6
10 XBATSDPPS8
Standard
Pack
Catalog
Number
2.3 mm
10 XBATSMPSMT
10 Blue XBATSMPSIHBU
10 White XBATSMPSIHWH
10 Red XBATSMPSIHRD
10 Black XBATSMPSIHBK
4 mm
10 XBATSPSMT
10 Blue XBATSPSIHBU
10 White XBATSPSIHWH
10 Red XBATSPSIHRD
10 Black XBATSPSIHBK
XBATSPAI4
XBATS_
XBATSMP_
XBATSMP_
V7-T8-106 Volume 7—Logic Control, Operator Interface and Connectivity Solutions CA08100008E—November 2011 www.eaton.com
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8.2
Terminal Blocks, Fuse Blocks and Fuse Holders
NEMA
NEMA
Contents
Description Page
NEMA
C381 Series Terminal Blocks, Rail Mounted . . V7-T8-107
TB Series Terminal Blocks, Modular . . . . . . . . . V7- T8 -111
NEMA Overview
Product Description
NEMA terminal blocks
provide a panel or DIN rail
mount block that can be
assembled from modular
pieces. These blocks
accommodate wire from
22 to 1/0 AWG and up to
175A and 600V.
Standards and Certifications
UL File #E67464 and
#E56797
Volume 7—Logic Control, Operator Interface and Connectivity Solutions CA08100008E—November 2011 www.eaton.com V7-T8-107
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8.2
Terminal Blocks, Fuse Blocks and Fuse Holders
NEMA
C381 Series Terminal Blocks, Rail Mounted
Contents
Description Page
C381 Series Terminal Blocks, Rail Mounted
Product Selection . . . . . . . . . . . . . . . . . . . . . . . V7-T8-108
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . V7-T8-109
Modifications . . . . . . . . . . . . . . . . . . . . . . . . . . V7-T8-109
Technical Data and Specifications . . . . . . . . . . V7-T8-110
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . V7-T8-110
TB Series Terminal Blocks, Modular . . . . . . . . . . . . V7-T8-111
C381 Series Terminal Blocks, Rail Mounted
Product Description
600V
Snap-fit nylon sections
Control circuit blocks
Power circuit blocks
Fuse blocks
Switch blocks
Sections can be interlocked
in any quantity and any
mixture for direct panel
mounting or channel
mounting
Three terminal choices in
control circuit blocks, up to
32 circuits per foot
Power circuit blocks for
heavy-duty applications, up
to 16 circuits per foot
Fuse blocks accommodate
any 0.406 x 1.5 in (10.3 x
38.1 mm) ferrule type
cartridge fuse up to 30A
Switch blocks have
removable blade for extra
safety
Standards and Certifications
UL File #E67464
A Typical Mixture of Control Circuit Blocks, Power Blocks, Switch and
Fuse Blocks in a Mounting Channel
C381PEC381TP C381PT C381EF C381SB C381FB
C381MC
C381CC
V7-T8-108 Volume 7—Logic Control, Operator Interface and Connectivity Solutions CA08100008E—November 2011 www.eaton.com
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8.2
Terminal Blocks, Fuse Blocks and Fuse Holders
NEMA
Product Selection
When Ordering Specify
Catalog number and quantity,
which must be in a multiple
of the available minimum
standard package.
Examples:
200 Cat. No. C381ST
20 Cat. No. C381PT
100 Cat. No. C381CC
Catalog number and quantity
of end sections also in
minimum quantity standard
package.
Example:
25 Cat. No. C381ES.
Control, Power, Switch and Fuse Blocks 1
Notes
1 Available only in minimum quantity standard packages.
2 Must be ordered in standard package quantity or in multiples of these quantities.
Description
AWG
Wire Size
Standard
Pack 2
Catalog
Number
Control Circuit Terminal Blocks—Rated 50A
Type ST (screw terminal) 22–14 AWG 100 C381ST
Type TP (tubular pressure plt) 22–10 100 C381TP
Type TS (tubular screw) end section 18–8 100 C381TS
End section 25 C381ES
Power Circuit Terminal Blocks—Rated 155A
Type PT (tubular screw) 10–1/0 10 C381PT
End section 10 C381PE
Switch Blocks—Rated 15A and Fuse Blocks—Rated 30A
Switch blocks 18–8 10 C381SB
Fuse blocks 18–8 10 C381FB
End section 10 C381EF
C381ST
C381TP
C381TS
C381ES
C381PT
C381PE
C381SB
C381FB
C381EF
Volume 7—Logic Control, Operator Interface and Connectivity Solutions CA08100008E—November 2011 www.eaton.com V7-T8-109
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8.2
Terminal Blocks, Fuse Blocks and Fuse Holders
NEMA
Accessories
C381 Series Terminal Blocks, Rail Mounted 1
Modifications
Pull Apart Terminal Blocks 1
Pull Apart Terminal Blocks
Illustrates: One–Three-Pole Movable Section,
Three–One-Pole Stationary Sections and One–End Piece
Notes
1Available only in minimum quantity standard packages.
2Must be ordered in standard package quantity or in multiples of these quantities.
3C381CC is a snap-in, one time use disposable type. C381VC can be readjusted or reused as desired.
4For use on adjacent Type TP and/or TS control circuit sections.
5May be used on section covers or to gang fuse and/or switch blocks.
6L shaped plug installs in end of stationary section, Catalog Number C381PS, and prevents incorrect installation of movable section, Catalog Number C381PM.
Description
Standard
Pack 2
Catalog
Number
Aluminum mounting channel—6 ft (1.8m) lengths 25 C381MC
Screw type channel clamp (one required each end) 3100 C381VC
Spring type channel clamp (one required each end) 3100 C381CC
Vinyl marking strip—3/8 in x 25 ft (9.5 mm x 7.6m) coil 1 C381MS
Marking paper—pressure sensitive—5/16 x 11-11/16 in (7.9 x 296.9 mm), 24 strips/sheet 5 sheets C381MP
Marking strip retainer (one required/grouping)
For use on control circuit blocks 100 C381SR
For use on power circuit blocks 100 C381SP
Fanning strip—for type TP and/or TS 50 C381TF
Fanning strip—for type ST 50 C381SF
Terminal jumper (two-pole) 4100 C381TJ
Ganging rod—1/8 in x 6 in (3.2 mm x 152.4 mm) 510 C381GR
Description
AWG
Wire Size
Standard
Pack 2
Catalog
Number
One-pole stationary section (tubular pressure plt) 22–10 100 C381PS
Three-pole movable section (tubular pressure plt) 22–10 12 C381PM
End section 25 C381ES
Polarizing plug (promotes alignment of poles) 6 100 C381PP
V7-T8-110 Volume 7—Logic Control, Operator Interface and Connectivity Solutions CA08100008E—November 2011 www.eaton.com
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8.2
Terminal Blocks, Fuse Blocks and Fuse Holders
NEMA
Technical Data and Specifications
Formulas for Calculating Blocks and Channel Lengths
N = Number of Blocks
C381 Series Terminal Blocks, Rail Mounted
Dimensions
Approximate Dimensions in Inches (mm)
C381 Series Terminal Blocks, Rail Mounted
Description Blocks Length
Control blocks and pull apart blocks 0.762 + (0.375 x N)
Power circuit blocks 0.812 + (0.750 x N)
Fuse and switch blocks 0.812 + (0.755 x N)
Mounting channel (minimum channel length) 0.75 + blocks length
Block A B
Control circuit blocks 1.25 (31.8) 1.55 (39.4)
Power circuit blocks 1.75 (44.5) 2.00 (50.8)
Fuse blocks 2.75 (69.9) 2.00 (50.8)
Switch blocks 2.75 (69.9) 2.00 (50.8)
Pull apart blocks 1.88 (47.8) 2.75 (69.9)
A
1.19
(30.2)
Channel
Mounting
Terminal Block Mounting
Without Channel
B
Mounting Channel in 6' (1.8m) Lengths,
Can Be Cut to Desired Length
Volume 7—Logic Control, Operator Interface and Connectivity Solutions CA08100008E—November 2011 www.eaton.com V7-T8-111
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8.2
Terminal Blocks, Fuse Blocks and Fuse Holders
NEMA
TB Series Terminal Blocks, Modular
Contents
Description Page
C381 Series Terminal Blocks, Rail Mounted . . . . . V7-T8-107
TB Series Terminal Blocks, Modular
Product Selection . . . . . . . . . . . . . . . . . . . . . . . V7-T8-112
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . V7-T8-113
Technical Data and Specifications . . . . . . . . . . V7-T8-114
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . V7-T8-115
TB Series Terminal Blocks, Modular
Product Description
TBA and TBD modular terminal
blocks are designed to
conserve space, while
allowing maximum flexibility
and ease of installation.
Available as one-, two- and
three-pole circuits, simple
and uniform installation is
possible because their
design is based on 5/8 in
(15.9 mm) modules. Standard
blocks are white nylon.
Breathing Action
Clamping Collar
The unique design of the
clamping collar permits the
collar to breathe as the wire
expands and contracts,
maintaining a constant
and permanent clamping
pressure. This eliminates
loose connections resulting
from the gradual flattening
of conductors and joint
deterioration caused by
heating and cooling cycles.
Features
Blocks—Design Features
Compact design permits
mounting 48–600V or
90–300V terminals per foot
Fully shielded construction,
600V spacings
Nylon construction
provides anti-tracking and
impact resistance
TBA types are available
in rail mounted, base
mounted and power
distribution types
Terminal blocks easily snap
on or off mounting rails;
not necessary to disturb
adjacent units
No end pieces or backing
plates are needed when
rail mounting
A 12 circuit subminiature
blocks, rated 20A at 300V,
is available for “high
density” applications
Popular blocks are also
available in dual mount for
use with standard TBA or
35 mm DIN rails
Terminals—Design Features
Insulated walls of lug
guide wire into lug
Blocks are shipped
with clamping screw
backed out
Constant locking torque
keeps terminal screws in
position
Terminal screws are captive;
cannot be lost in shipment
or handling
Hardened stainless steel
clamping collar eliminates
stripped threads
Large opening in clamping
collar accommodates
oversized conductors;
smallest collar will accept
three 14 AWG stranded
conductors
Standards and Certifications
UL recognized: File No.
E56797
CE approved
V7-T8-112 Volume 7—Logic Control, Operator Interface and Connectivity Solutions CA08100008E—November 2011 www.eaton.com
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8.2
Terminal Blocks, Fuse Blocks and Fuse Holders
NEMA
Product Selection
TBA Modular Terminal Blocks
Rail and Base Mounted Terminal Blocks
Notes
1Based on 50°C rise, test at 25°C ambient while using maximum wire size.
2Must be ordered in standard package quantity or in multiples of these quantities.
3Dual mounting blocks—mount on either TMR/TBA rail or 35 mm DIN rail.
4May also be mounted on mini-DIN rail (15 mm). Catalog Number C383TS15.
5May also be base mounted.
6TBU Series = 60A with crimped wire.
Description
AWG
Wire Size
Number
of Poles
Ampacity
(per Circuit) 1
Carton
Quantity 2
TBA Rail DIN Rail 3
Catalog
Number
Catalog
Number
Rail Mounted—600V
Subminiature blocks (2) 14–12 12 5A 100 TBDSM12 4TBDSM12 4
Miniature blocks 22–10 4 30A 100 TBDV4 TBDV4
Standard blocks—screw terminals
with tang clamping collars
18–2 1 90A 100 TBDT1
22–8 2 40A 100 TBAT2 —
22–8 3 40A 20 TBAT3-20 TBDT3-20
18–4 3 90A 100 TBDT70 TBDT70
High current blocks 14–2/0 3 175A 12 TBA100 5
Standard blocks—plug-in terminals 22–8 3 40A 20 TBAP —
18–4 3 70A 20 TBAP70
14–8 3 40A 20 TBAPL70
Panel mount blocks 22–10 3 30A 100 TBAL30 —
8–4 3 115A 12 TBAL90 —
Disconnect blocks—for 1/4 in (6.4 mm) dia.
by 1–1-7/16 in (25.4–36.5 mm) fuse
22–8 1 30A 50 TBAD
Fuse blocks—for 13/32 in (10.3 mm) dia.
by 1-1/2 in (38.1 mm) fuse
22–8 1 30A 50 TBDTF TBDTF
Base Mounted—600V
Miniature blocks—screw terminals
with tang clamping collars
22–10 4 30A (600V) 90 TBBT4 —
Standard blocks—standard screw terminals 22–8 3 40A 80 TBABT3
Universal mounting blocks 8 maximum 4 50A 625 TBU4
8 maximum 6 50A 660 TBU6
8 maximum 8 50A 6 45 TBU8
8 maximum 12 50A 635 TBU12
Volume 7—Logic Control, Operator Interface and Connectivity Solutions CA08100008E—November 2011 www.eaton.com V7-T8-113
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8.2
Terminal Blocks, Fuse Blocks and Fuse Holders
NEMA
Accessories
TB Series Terminal Blocks, Modular
Notes
1Length in inches (mm) except as noted.
2Must be ordered in standard package quantity or in multiples of these quantities.
Description Length 1
Number
of Poles
Carton
Quantity 2
Catalog
Number
Mounting Rail
Aluminum 12.5 (317.5) 25 TMR12
37.5 (952.5) 25 TMR37
72.0 (1828.8) 25 TBATR72
35 mm DIN—steel 1m 20 MC382MA1-20
Marking Strips
Miniature blocks—TBDV4 and TBBT4 6.0 (152.4) 50 TMS6
TBU Series—matte finish 7.5 (190.5) 25 TMSU
All other blocks 12.5 (317.5) 50 TMS
Jumpers
TBAT1 and TBAP70 2-pole 100 TJ1
TBAT2 2-pole 100 TJ2
TBAT3, TBABT3, TBAP and TBBP 2-pole 100 TJ3
TBDV4 and TBBT4 4-pole 100 TJ4
TBAD and TBATF 2-pole 100 TJ5
TBAL30 2-pole 100 TJ6
TBU 12-pole 10 TJ7
TBDT3 2-pole 100 TJ8
Miscellaneous
End piece for TBABT3 and TBBP 50 TAD
Lug shield for TBA100 and TBAL90 50 TAS
Fuse puller 50 TBP
Lighted fuse puller—blown fuse indication 25 TBLP
V7-T8-114 Volume 7—Logic Control, Operator Interface and Connectivity Solutions CA08100008E—November 2011 www.eaton.com
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8.2
Terminal Blocks, Fuse Blocks and Fuse Holders
NEMA
Technical Data and Specifications
TB Series Terminal Blocks, Modular
Chemical resistance to:
Acetone
Ammonia gas
Benzene
Gasoline
Mineral oil
Sodium bisulfate
Sodium chloride
Sodium nitrate
Water up to 50°C
Flashover Voltages Recommended Terminal
Tightening Torque
To find a current rating, place
a straight edge horizontally at
the value of anticipated
maximum internal panel
ambient (scale on the left),
and read the current rating for
the device on the bottom
scale. Example: at 60°C,
TBAT3 is rated 54 amperes.
Ampere rating is based
on maximum allowable
temperature—ambient
temperature plus
temperature rise due
to current.
Ratings based on 90°C total
temperature of a three-pole
block with each pole carrying
current and wired with largest
size conductors.
Temperature Rating
Description Specification
Continuous temperature 212°F (100°C)
Tensile strength 10,000–12,000 psi
Impact resistance 2.0 ft-lb/in (arc)
Arc resistance 140 seconds
Vac rms, 60 Hz
Catalog
Number
Opposite
Polarity To Ground
TBAT1 9100 6600
TBAT2 9600 7300
TBAT3 8600 7300
Wire Size Torque
Up to 8 AWG 20 lb-in
Up to 4 AWG 35 lb-in
Up to 2/0 AWG 50 lb-in
30
20
Ambient Temp. in C°
Temp. Rise in C°
40 60 80 100 120 140 160 180
Current in Amps
200 220 240
40
50
60
70
80
60
50
40
30
20
10
TBAM4 TBAB70
TBAL90
TBAL100
TBAT2
TBAT3
TBAT1
TBAP
TBAL30
Volume 7—Logic Control, Operator Interface and Connectivity Solutions CA08100008E—November 2011 www.eaton.com V7-T8-115
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8.2
Terminal Blocks, Fuse Blocks and Fuse Holders
NEMA
Dimensions
Approximate Dimensions in Inches (mm)
TB Series Terminal Blocks, Modular
0.88
(22.4)
1.09
(27.7)
TBDSM12
TBAP70 & TBAPL70
2.4 (61)
1.88
(47.8)
0.63
(16)
1.48
(37.6) 1.86
(47.2)
1.25
(31.8)
2 (50.8)
1
(25.4)
TBDV4 TBDT1
TBAT3 & TBDT3
1.25
(31.8)
1.23
(31.2)
1.71
(43.4)
1.3
(33)
0.59
(15)
TBAT2
TBA100
TBDT70
1.69
(42.9)
1.3
(33)
0.63 (16) 1.25
(31.8)
1.34
(34)
1.75
(44.5)
0.63
(16)
3.13 (79.5) 1.53 (38.9)
1.25 (31.8)
TBAL30
1.25
(31.8)
1.25
(31.8)
#6-32
Screw 1.33
(33.8)
1.23
(31.2)
1.3
(33)
TBAP
0.59
(15)
1.25
(31.8)
1.86
(47.2)
1.77 (45)
TBU4, TBU6, TBU8 & TBU12
0.31 (7.9)
0.25 (6.4) 0.63 (16)
0.66
(16.8) 0.19
(4.8)
12.5 – 37.5
(317.5 – 952.5)
TMR12 & TMR37
2
(50.8)
1.5
(38.1)
0.5
(12.7)
1.25
(31.8)
0.63 (16)
#10 Screw
Clearance
B
0.63
(16)
1.23
(31.2)
1.25
(31.8)
1 (25.4)
1.38 (35.1)
1.78 (45.2)
TBBT4
0.17 – 0.28
(4.3 – 7.1)
Clearance for
#8 Screw
0.44 (11.2)
A
1.88 (47.8)
TBAD & TBDTF
2
(50.8)
1.25
(31.8)
0.63 (16)
0.63 (16)
0.47 (11.9)
1.94 (49.3)
3 Holes
0.09 (2.3) Dia.
0.33 (8.4) Deep
0.67
(17) 0.59
(15)
1.75
(44.5)
1/4-28
Screw
TBAL90
1.53
(38.9)
0.63
(16) 1.25
(31.8)
3.13 (79.5)
TBABT3
1.25
(31.8)
1.19
(30.2)
2.47 (62.7)
1.88 (47.8)
0.17 – 0.27
(4.3 – 6.9)
Clearance for
#8 Screw
Footlock
Cat. #TAD
#10 Screw
Clearance 1.31
(33.3)
72 (1828.8)
0.13 (3.3) 0.63 (16)
0.56
(14.2) TBATR72
0.25 (6.4) 1.25 (31.8)
TBU4
TBU6
TBU8
TBU12
3.75
(95.3)
5
(127)
6.25
(158.8)
8.75
(222.3)
2.87
(72.9)
AB
4.12
(104.6)
5.37
(136.4)
7.87
(199.9)
V7-T8-116 Volume 7—Logic Control, Operator Interface and Connectivity Solutions CA08100008E—November 2011 www.eaton.com
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8.3
Terminal Blocks, Fuse Blocks and Fuse Holders
Power Distribution
Power Distribution Products
Contents
Description Page
Power Distribution
CHDB Series—Power Distribution Blocks . . . . V7-T8-117
CH160 Series—Power Terminal Blocks . . . . . . V7-T8-123
Power Terminal Block Accessories . . . . . . . . . . V7-T8-126
Power Distribution Overview
Product Selection Guide
Notes
1Refer to Page V7-T8-118 to determine short circuit current ratings with fuses and Pages V7-T8-119 and V7-T8-120 to determine short circuit current ratings
in conjunction with specific Eaton circuit breakers.
2Single-pole units, when installed with proper spacings, may meet requirements for UL 508A feeder circuits.
Series
Current
Range UL Certification
High Short
Circuit Current
Rating 1
UL 508A Approved for Industrial Control Panels
HVAC UL 1995Branch Circuits Feeder Circuits
CH162 115–175A UL 1059 Recognized No Yes No 2Yes
CH163 175–420A UL 1059 Recognized No Yes No 2Yes
CH165 620–840A UL 1059 Recognized No Yes No 2Yes
CHDB 175–570A UL 1953 Listed Yes Yes Yes Yes
Volume 7—Logic Control, Operator Interface and Connectivity Solutions CA08100008E—November 2011 www.eaton.com V7-T8-117
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8.3
Terminal Blocks, Fuse Blocks and Fuse Holders
Power Distribution
CHDB Series—Power Distribution Blocks, Enclosed and Open
Contents
Description Page
CHDB Series—Power Distribution Blocks
Product Selection . . . . . . . . . . . . . . . . . . . . . . . V7-T8-118
Technical Data and Specifications . . . . . . . . . . V7-T8-118
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . V7-T8-121
CH160 Series—Power Terminal Blocks . . . . . . . . . V7-T8-123
Power Terminal Block Accessories . . . . . . . . . . . . V7-T8-126
CHDB Series—Power Distribution Blocks
Product Description
Eaton’s CHDB Series of
Power Distribution Blocks
was designed for high short
circuit current rating (SCCR)
applications up to 200,000
amperes. They are assembled
with the minimum spacing to
meet UL 1953 requirements
for feeder circuits in UL 508A
industrial control panels,
and provide significant
wiring flexibility.
Available in three-pole
open style and single-pole
enclosed style with a variety
of terminal arrangements
and current-carrying capability
up to 570 amperes.
Features and Benefits
Enclosed Style
IP20 finger-safe enclosure
600 Vac or Vdc (UL 1953),
690 Vac or Vdc
DIN rail or panel mount
Captive termination screws
prevent lost screws
Single-pole, gang
mountable for multi-pole
applications
Tin plated Al connections
suitable for Cu conductors
Flammability, UL 94V-0
Open Style
600 Vac or Vdc (UL 1953)
Panel mount
Three-pole open design for
easy wiring
Tin-plated Al connections
suitable for Cu conductors
Flammability, UL 94V-0
Available covers for
additional protection
(does not meet IP20)
Standards and Certifications
UL Listed 1953, Guide
QPQS, File E256146
CSA Certified,
Class 6228-01, File 15364
(enclosed style)
CE Component
IEC 60947-7-1
(enclosed style)
IEC 60529, IP20 (finger-
safe) under specific wiring
conditions (enclosed style)
V7-T8-118 Volume 7—Logic Control, Operator Interface and Connectivity Solutions CA08100008E—November 2011 www.eaton.com
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8.3
Terminal Blocks, Fuse Blocks and Fuse Holders
Power Distribution
Product Selection
CHDB Series—Power Distribution Blocks
Technical Data and Specifications
Power Terminal Block Short-Circuit Current Ratings (SCCR) with Fuses
Note
1Finger-safe.
Line Connection Load Connection Configuration Amperes Style Poles
Catalog
Number
2/0–#8 AWG (4) #4–#14 AWG 175 Open 3 CHDB2203
2/0–#8 AWG (6) #4–#14 AWG 175 Open 3 CHDB3213
300 kcmil–#4 AWG (6) #4–#12 AWG 310 Open 3 CHDB3233
300 kcmil–#4 AWG (12) #4–#14 AWG 310 Open 3 CHDB3703
300 kcmil–#4 AWG (6) #2–#12 AWG 310 Open 3 CHDB3713
(3) 1/0–#12 AWG 310 Open 3 CHDB3713
2/0–#8 AWG 2/0–#8 AWG 175 Enclosed 11CHDB204F
500 kcmil–#6 AWG (6) #2–#14 AWG 380 Enclosed 11CHDB330F
300 kcmil–#4 AWG (12) #4–#14 AWG 570 Enclosed 11CHDB377F
Catalog
Number
Terminal Copper Conductors
Maximum Fuse Class and Amperes
J T RK-1 RK-5
SCCR (kA)Line Load LPJ JJS/JJN LPS-RK/LPN-RK FRS-R/FRN-R
CHDB2203 2/0–#8 AWG #4–#12 AWG 200 200 200 60 200
#4–#14 AWG 175 175 100 60 100
200 200 100 60 50
CHDB3213 2/0–#8 AWG #4–#12 AWG 400 400 200 100 200
400 400 400 100 100
#4–#14 AWG 175 175 100 60 100
CHDB3233 300 kcmil–#4 AWG #4–#8 AWG 400 400 200 100 200
400 400 400 100 100
#4–#12 AWG 175 175 100 60 100
CHDB3703 300 kcmil–#4 AWG #4–#8 AWG 400 400 200 100 200
#4–#14 AWG 400 400 400 100 100
175 175 100 60 100
CHDB3713 300 kcmil–#4 AWG 1/0–#6 AWG 400 400 200 100 200
#4–#12 AWG 400 400 400 100 100
175 175 100 60 100
CHDB204F 2/0–#8 AWG 2/0–#8 AWG 200 200 100 60 200
CHDB330F 500 kcmil–#6 AWG #2–#6 AWG 400 400 200 100 200
#2–#14 AWG 200 200 100 30 50
175 175 100 30 100
CHDB377F 300 kcmil #4–#8 AWG 600 600 400 200 200
300 kcmil–#4 AWG #4 AWG 600 600 400 200 50
#4–#14 AWG 200 200 100 30 50
CHDB2203 (Open)
CHDB204F (Enclosed)
Volume 7—Logic Control, Operator Interface and Connectivity Solutions CA08100008E—November 2011 www.eaton.com V7-T8-119
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8.3
Terminal Blocks, Fuse Blocks and Fuse Holders
Power Distribution
Power Terminal Block Short-Circuit Ratings (SCCR) for UL 508A Applications with Circuit Breakers
Note
1This breaker frame is marked current limiting and suitable for use as current limiting per UL 508A SB.4.3.2.
Catalog
Number Description
Enclosure Size in
Inches (mm)
Current
Rating
Opening per Pole Line
Conductors
Cu
Load
Conductors
Cu
SCCR @ 480V
(Load Side)
Eaton
Breaker
Available Breaker
Current RatingsLine Load
CHDB2203 Feeder Listed
Open PDB
16.00 x 16.00 x 6.75
(406.4 x 406.4 x 171.5)
175 2/0–#8 #4–#10
#12
#14
18 kA
18 kA
14 kA
EGB125 15, 20, 25, 30, 35, 40,
45, 50, 60, 70, 80, 90,
100, 125
CHDB2203 Feeder Listed
Open PDB
16.00 x 16.00 x 6.75
(406.4 x 406.4 x 171.5)
175 2/0–#8 #4–#10
#12
#14
25 kA
22 kA
14 kA
EGE125 15, 20, 25, 30, 35, 40,
45, 50, 60, 70, 80, 90,
100, 125
CHDB2203 Feeder Listed
Open PDB
16.00 x 16.00 x 6.75
(406.4 x 406.4 x 171.5)
175 2/0–#8 #4–#10
#12
#14
50 kA
22 kA
14 kA
EGS125 15, 20, 25, 30, 35, 40,
45, 50, 60, 70, 80, 90,
100, 125
CHDB2203 Feeder Listed
Open PDB
16.00 x 16.00 x 6.75
(406.4 x 406.4 x 171.5)
175 2/0–#8 #4–#10
#12
#14
65 kA
22 kA
14 kA
EGH125 15, 20, 25, 30, 35, 40,
45, 50, 60, 70, 80, 90,
100, 125
CHDB2203 Feeder Listed
Open PDB
16.00 x 16.00 x 6.75
(406.4 x 406.4 x 171.5)
175 2/0–#8 #4–#10
#12
#14
65 kA
22 kA
14 kA
EGC125 115, 20, 25, 30, 35, 40,
45, 50, 60, 70, 80, 90,
100, 125
CHDB3213 Feeder Listed
Open PDB
24.00 x 20.00 x 6.75
(609.6 x 508.0 x 171.5)
175 2/0–#8 #4–#10
#12
#14
18 kA
18 kA
18 kA
EGB125 15, 20, 25, 30, 35, 40,
45, 50, 60, 70, 80, 90,
100, 125
CHDB3213 Feeder Listed
Open PDB
24.00 x 20.00 x 6.75
(609.6 x 508.0 x 171.5)
175 2/0–#8 #4–#10
#12
#14
25 kA
22 kA
18 kA
EGE125 15, 20, 25, 30, 35, 40,
45, 50, 60, 70, 80, 90,
100, 125
CHDB3213 Feeder Listed
Open PDB
24.00 x 20.00 x 6.75
(609.6 x 508.0 x 171.5)
175 2/0–#8 #4–#10
#12
#14
50 kA
22 kA
18 kA
EGS125 15, 20, 25, 30, 35, 40,
45, 50, 60, 70, 80, 90,
100, 125
CHDB3213 Feeder Listed
Open PDB
24.00 x 20.00 x 6.75
(609.6 x 508.0 x 171.5)
175 2/0–#8 #4–#10
#12
#14
65 kA
22 kA
18 kA
EGH125 15, 20, 25, 30, 35, 40,
45, 50, 60, 70, 80, 90,
100, 125
CHDB3213 Feeder Listed
Open PDB
24.00 x 20.00 x 6.75
(609.6 x 508.0 x 171.5)
175 2/0–#8 #4–#10
#12
#14
65 kA
22 kA
18 kA
EGC125 115, 20, 25, 30, 35, 40,
45, 50, 60, 70, 80, 90,
100, 125
CHDB204F Feeder Listed
Enclosed PDB
16.00 x 16.00 x 6.75
(406.4 x 406.4 x 171.5)
175 2/0–#8 2/0–#8 18 kA EGB125 15, 20, 25, 30, 35, 40,
45, 50, 60, 70, 80, 90,
100, 125
CHDB204F Feeder Listed
Enclosed PDB
16.00 x 16.00 x 6.75
(406.4 x 406.4 x 171.5)
175 2/0–#8 2/0–#8 25 kA EGE125 15, 20, 25, 30, 35, 40,
45, 50, 60, 70, 80, 90,
100, 125
CHDB204F Feeder Listed
Enclosed PDB
16.00 x 16.00 x 6.75
(406.4 x 406.4 x 171.5)
175 2/0–#8 2/0–#8 35 kA EGS125 15, 20, 25, 30, 35, 40,
45, 50, 60, 70, 80, 90,
100, 125
CHDB204F Feeder Listed
Enclosed PDB
16.00 x 16.00 x 6.75
(406.4 x 406.4 x 171.5)
175 2/0–#8 2/0–#8 65 kA EGH125 15, 20, 25, 30, 35, 40,
45, 50, 60, 70, 80, 90,
100, 125
CHDB204F Feeder Listed
Enclosed PDB
16.00 x 16.00 x 6.75
(406.4 x 406.4 x 171.5)
175 2/0–#8 2/0–#8 65 kA EGC125 115, 20, 25, 30, 35, 40,
45, 50, 60, 70, 80, 90,
100, 125
CHDB3233 Feeder Listed
Open PDB
24.00 x 20.00 x 6.75
(609.6 x 508.0 x 171.5)
310 350 kmil–#4 #4–#6
#8
#10
25 kA
25 kA
14 kA
JGE250 70, 90, 100, 125, 150,
175, 200, 225, 250
CHDB3233 Feeder Listed
Open PDB
24.00 x 20.00 x 6.75
(609.6 x 508.0 x 171.5)
310 350 kmil–#4 #4–#6
#8
#10
35 kA
35 kA
14 kA
JGS250 70, 90, 100, 125, 150,
175, 200, 225, 250
CHDB3233 Feeder Listed
Open PDB
24.00 x 20.00 x 6.75
(609.6 x 508.0 x 171.5)
310 350 kmil–#4 #4–#6
#8
#10
65 kA
42 kA
14 kA
JGH250 70, 90, 100, 125, 150,
175, 200, 225, 250
CHDB3233 Feeder Listed
Open PDB
24.00 x 20.00 x 6.75
(609.6 x 508.0 x 171.5)
310 350 kmil–#4 #4–#6
#8
#10
65 kA
42 kA
25 kA
JGC250 170, 90, 100, 125, 150,
175, 200, 225, 250
V7-T8-120 Volume 7—Logic Control, Operator Interface and Connectivity Solutions CA08100008E—November 2011 www.eaton.com
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8.3
Terminal Blocks, Fuse Blocks and Fuse Holders
Power Distribution
Power Terminal Block Short-Circuit Ratings (SCCR) for UL 508A Applications with Circuit Breakers, continued
Note
1This breaker frame is marked current limiting and suitable for use as current limiting per UL 508A SB.4.3.2.
Catalog
Number Description
Enclosure Size in
Inches (mm)
Current
Rating
Opening per Pole Line
Conductors
Cu
Load
Conductors
Cu
SCCR at 480V
(Load Side)
Eaton
Breaker
Available Breaker
Current RatingsLine Load
CHDB3703 Feeder Listed
Open PDB
24.00 x 20.00 x 6.75
(609.6 x 508.0 x 171.5)
310 350 kmil–#4 #4–#6
#8
#10
25 kA
25 kA
14 kA
JGE250 70, 90, 100, 125, 150,
175, 200, 225, 250
CHDB3703 Feeder Listed
Open PDB
24.00 x 20.00 x 6.75
(609.6 x 508.0 x 171.5)
310 350 kmil–#4 #4–#6
#8
#10
35 kA
35 kA
14 kA
JGS250 70, 90, 100, 125, 150,
175, 200, 225, 250
CHDB3703 Feeder Listed
Open PDB
24.00 x 20.00 x 6.75
(609.6 x 508.0 x 171.5)
310 350 kmil–#4 #4–#6
#8
#10
65 kA
42 kA
14 kA
JGH250 70, 90, 100, 125, 150,
175, 200, 225, 250
CHDB3703 Feeder Listed
Open PDB
24.00 x 20.00 x 6.75
(609.6 x 508.0 x 171.5)
310 350 kmil–#4 #4–#6
#8
#10
65 kA
42 kA
25 kA
JGC250 170, 90, 100, 125, 150,
175, 200, 225, 250
CHDB3713 Feeder Listed
Open PDB
24.00 x 20.00 x 6.75
(609.6 x 508.0 x 171.5)
310 350 kmil–#4 #4–#6
#8
#10
25 kA
25 kA
14 kA
JGE250 70, 90, 100, 125, 150,
175, 200, 225, 250
CHDB3713 Feeder Listed
Open PDB
24.00 x 20.00 x 6.75
(609.6 x 508.0 x 171.5)
310 350 kmil–#4 #4–#6
#8
#10
35 kA
35 kA
14 kA
JGS250 70, 90, 100, 125, 150,
175, 200, 225, 250
CHDB3713 Feeder Listed
Open PDB
24.00 x 20.00 x 6.75
(609.6 x 508.0 x 171.5)
310 350 kmil–#4 #4–#6
#8
#10
50 kA
42 kA
14 kA
JGH250 70, 90, 100, 125, 150,
175, 200, 225, 250
CHDB3713 Feeder Listed
Open PDB
24.00 x 20.00 x 6.75
(609.6 x 508.0 x 171.5)
310 350 kmil–#4 #4–#6
#8
#10
65 kA
50 kA
25 kA
JGC250 170, 90, 100, 125, 150,
175, 200, 225, 250
CHDB330F Feeder Listed
Enclosed PDB
24.00 x 20.00 x 6.75
(609.6 x 508.0 x 171.5)
380 500 kmil–#3 #2–#8 14 kA LGE400 250, 300, 350, 400
CHDB330F Feeder Listed
Enclosed PDB
24.00 x 20.00 x 6.75
(609.6 x 508.0 x 171.5)
380 500 kmil–#3 #2–#8 14 kA LGS400 250, 300, 350, 400
CHDB330F Feeder Listed
Enclosed PDB
24.00 x 20.00 x 6.75
(609.6 x 508.0 x 171.5)
380 500 kmil–#3 #2–#8 14 kA LGH400 250, 300, 350, 400
CHDB330F Feeder Listed
Enclosed PDB
24.00 x 20.00 x 6.75
(609.6 x 508.0 x 171.5)
380 500 kmil–#3 #2–#8 25 kA LGC400 1250, 300, 350, 400
CHDB377F Feeder Listed
Enclosed PDB
24.00 x 20.00 x 6.75
(609.6 x 508.0 x 171.5)
570 (2) 300 kmil–#2 #4
#6
#8
30 kA
18 kA
14 kA
LGE600 250, 300, 350, 400,
500, 600
CHDB377F Feeder Listed
Enclosed PDB
24.00 x 20.00 x 6.75
(609.6 x 508.0 x 171.5)
570 (2) 300 kmil–#2 #4
#6
#8
30 kA
18 kA
14 kA
LGS600 250, 300, 350, 400,
500, 600
CHDB377F Feeder Listed
Enclosed PDB
24.00 x 20.00 x 6.75
(609.6 x 508.0 x 171.5)
570 (2) 300 kmil–#2 #4
#6
#8
30 kA
18 kA
14 kA
LGH600 250, 300, 350, 400,
500, 600
CHDB377F Feeder Listed
Enclosed PDB
24.00 x 20.00 x 6.75
(609.6 x 508.0 x 171.5)
570 (2) 300 kmil–#2 #4
#6
#8
42 kA
35 kA
14 kA
LGC600 1250, 300, 350, 400,
500, 600
Volume 7—Logic Control, Operator Interface and Connectivity Solutions CA08100008E—November 2011 www.eaton.com V7-T8-121
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8.3
Terminal Blocks, Fuse Blocks and Fuse Holders
Power Distribution
Dimensions
Approximate Dimensions in Inches (mm)
CHDB2203
CHDB3213
CHDB3233
CHDB3703
CHDB3713
CHDB204F
2.13
(54.1)
4.25
(108.0)
2.88
(73.2)
2221
1211 12
22
11
21 21
11
22
12
3.32
(84.3)
5.19
(131.8)
4.00
(101.6)
3.70
(94.0)
6.30
(160.0)
5.50
(139.7)
3.70
(94.0)
6.30
(160.0)
5.50
(139.7)
3.70
(94.0)
6.30
(160.0)
5.50
(139.7)
1.03
(26.2)
3.73
(94.7)
2.15
(54.6)
1.40
(35.6)
3.55
(90.2)
Line
Side
Load
Side
2.92
(74.2)
V7-T8-122 Volume 7—Logic Control, Operator Interface and Connectivity Solutions CA08100008E—November 2011 www.eaton.com
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8.3
Terminal Blocks, Fuse Blocks and Fuse Holders
Power Distribution
Approximate Dimensions in Inches (mm)
CHDB330F CHDB377F
1.54
(39.1)
Line
Side
Load
Side
4.66
(118.4)
3.82
(97.0)
2.87
(72.9)
1.40 (35.6)
4.49
(114.0)
Line
Side
Load
Side 1.86
(47.2)
4.66
(118.4)
2.93
(74.4)
1.40 (35.6)
4.49
(114.0)
3.82
(97.0)
Volume 7—Logic Control, Operator Interface and Connectivity Solutions CA08100008E—November 2011 www.eaton.com V7-T8-123
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8.3
Terminal Blocks, Fuse Blocks and Fuse Holders
Power Distribution
CH160 Series—Power Terminal Blocks
Contents
Description Page
CHDB Series—Power Distribution Blocks . . . . . . . V7-T8-117
CH160 Series—Power Terminal Blocks
Product Selection . . . . . . . . . . . . . . . . . . . . . . . V7-T8-124
Technical Data and Specifications . . . . . . . . . . V7-T8-125
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . V7-T8-125
Power Terminal Block Accessories . . . . . . . . . . . . V7-T8-126
CH160 Series—Power Terminal Blocks
Product Description
The CH160 Series of Power
Terminal Blocks are UL 1059
recognized power terminal
blocks for branch circuit
applications. All short circuit
current ratings (SCCR) are
10 kA per UL 508A Table
SB4.1. The blocks are
available in a wide variety
of wiring configurations,
providing excellent flexibility.
Features and Benefits
Ratings: To 840A, 600V
Materials
Molded material; black,
UL rated 94V-0
thermoplastic
Operating temperature:
302°F (150°C)
Optional cover:
See Page V7-T8-125
Standards and Certifications
UL Recognized
CSA Certified
V7-T8-124 Volume 7—Logic Control, Operator Interface and Connectivity Solutions CA08100008E—November 2011 www.eaton.com
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8.3
Terminal Blocks, Fuse Blocks and Fuse Holders
Power Distribution
Product Selection
When Ordering, Specify
Catalog number
Number of poles (up to three-pole available)
CH160 Power Terminal Blocks—CH162 Series
CH160 Power Terminal Blocks—CH163 Series
CH160 Power Terminal Blocks—CH165 Series
Note
1Incomplete catalog number—add code suffix -1, -2, -3 for number of poles.
Example: For a 150A 1/0-#14 Cu to 1/0-#14 Cu three-pole PDB, order CH16201-3.
Line Connection Load Connection
Connector Material
and Ampacity
Catalog
Number 1
#2–#14 Cu/#8 Al #2–#14 Cu/#8 Al Al 115A CH16200_
1/0–#14 Cu 1/0–#14 Cu Cu 150A CH16201_
2/0–#8 Cu/Al 2/0–#8 Cu/Al Al 175A CH16204_
2/0–#14 Cu/#8 Al (4) #4–#14 Cu/#8 Al Al 175A CH16220_
Line Connection Load Connection
Connector Material
and Ampacity
Catalog
Number 1
250 kcmil-#6 Cu 250 kcmil-#6 Cu Cu 255A CH16301_
350 kcmil-#6 Cu/Al 350 kcmil-#6 Cu/Al Al 310A CH16303_
500 kcmil-#6 Cu/Al 500 kcmil-#6 Cu/Al Al 380A CH16306_
2/0–#14 Cu/Al (6) #4–#14 Cu/#8 Al Al 175A CH16321_
350 kcmil-#6 Cu/Al (6) #4–#14 Cu/#8 Al Al 310A CH16323_
(2) 2/0–#14 Cu/#8 Al (6) #4–#14 Cu/#8 Al Al 350A CH16325_
500 kcmil-#6 Cu/Al (6) #2–#14 Cu/#8 Al Al 380A CH16330_
350 kcmil-#6 Cu/Al (3) #2–#14 Cu/#8 Al Al 310A CH16332_
(2) 1/0–#14 Cu/#8 Al Al 310A CH16332_
350 kcmil-#6 Cu/Al (12) #4–#14 Cu/#8 Al Al 310A CH16370_
350 kcmil-#6 Cu/Al (6) #2–#14 Cu/#8 Al Al 310A CH16371_
(3) 1/0–#14 Cu/#8 Al Al 310A CH16371_
350 kcmil-#6 Cu/Al (21) #10–#14 Cu/#10 Al Al 310A CH16372_
350 kcmil-#6 Cu/Al (3) 1/0–#14 Cu/#8 Al Al 310A CH16373_
(14) #10–#14 Cu/#8 Al Al 310A CH16373_
600 kcmil-#2 Cu/Al (12) #4–#14 Cu/#8 Al Al 420A CH16375_
600 kcmil-#2 Cu/Al (6) #2–#14 Cu/#8 Al Al 420A CH16376_
(3) 1/0–#14 Cu/#8 Al Al 420A CH16376_
Line Connection Load Connection
Connector Material
and Ampacity
Catalog
Number 1
(2) 350 kcmil-4 Cu/Al (2) 350 kcmil-4 Cu/Al Al 620A CH16500_
(2) 500 kcmil-#6 Cu/Al (2) 500 kcmil-#6 Cu/Al Al 760A CH16504_
(2) 600 kcmil-#2 Cu/Al (4) 3/0–#8 Cu/Al Al 840A CH16528_
(4) #4–#14 Cu/#8 Al Al 840A CH16528_
(2) 500 kcmil-#6 Cu/Al (12) #4–#14 Cu/#8 Al Al 760A CH16530_
Volume 7—Logic Control, Operator Interface and Connectivity Solutions CA08100008E—November 2011 www.eaton.com V7-T8-125
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8.3
Terminal Blocks, Fuse Blocks and Fuse Holders
Power Distribution
Technical Data and Specifications
CH160 Power Terminal Blocks
Note: For optional cover, see Power Terminal Block
Accessories, Page V7-T8-126.
Dimensions
Approximate Dimensions in Inches (mm)
Series CH163
(Single-, Two- and Three-Pole Available)
Series CH162 and CH165
(Single-, Two- and Three-Pole Available)
CH160 Power Terminal Block Dimensions
Description Specification
Ratings To 840A, 600V
Materials Molded material; black, UL rated 94V-0 thermoplastic
Operating temperature 302°F (150°C)
F
B
Mtg. Holes 0.21 x 0.41 (5.3 x 10.4)
C'Bore 0.42 x 0.62 x 0.12 Deep
(10.7 x 15.7 x 3.0 Deep)
D
G
J
A
E
E
C
F
B
0.20 (5.1) Dia. Hole with
0.40 (10.2) C’Bore
DG
J
H
A
E
E
C
Series A B
CCC
DE4F GHJSingle-Pole Two-Pole Three-Pole
CH162 2.87 (72.9) 2.25 (57.2) 1.06 (26.9) 1.87 (47.5) 2.68 (68.1) 1.75 (44.5) 0.81 (20.6) 0.53 (13.5) 0.31 (7.9) 0.84 (21.3) 0.31 (7.9)
CH163 4.00 (101.6) 3.37 (85.6) 1.96 (49.8) 3.58 (90.9) 5.20 (132.1) 3.32 (84.3) 1.62 (41.1) 0.97 (24.6) 0.31 (7.9) 0.87 (22.1) 0.35 (8.9)
CH165 5.50 (139.7) 4.75 (120.7) 3.12 (79.2) 5.81 (147.6) 8.50 (215.9) 3.12 (79.2) 2.68 (68.1) 1.56 (39.6) 0.37 (9.4) 1.37 (34.8) 0.62 (15.7)
V7-T8-126 Volume 7—Logic Control, Operator Interface and Connectivity Solutions CA08100008E—November 2011 www.eaton.com
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8.3
Terminal Blocks, Fuse Blocks and Fuse Holders
Power Distribution
Power Terminal Block Accessories
Contents
Description Page
CHDB Series—Power Distribution Blocks . . . . . . . V7-T8-117
CH160 Series—Power Terminal Blocks . . . . . . . . . V7-T8-123
Power Terminal Block Accessories
Technical Data and Specifications . . . . . . . . . . V7-T8-127
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . V7-T8-127
Power Terminal Block Accessories
Product Description
Protective Cover
Guards against accidental
contact
Clear with write-on surface
for field termination
identification
Available in single-, two-
and three-pole
Standards and Certifications
TB Series Power Blocks
Contact Eaton for the
latest UL 508A short circuit
ratings on terminal blocks
UL Recognized:
File No. E62622
CSA Certified:
File No. LR15364
Product Selection
When Ordering, Specify
Catalog number
CH163 Series Cover
TB Series Power Blocks
Note
1Standard pack, five pieces.
Description
Catalog
Number
Single-pole cover CHCPDB-1 1
Two-pole cover CHCPDB-2 1
Three-pole cover CHCPDB-3 1
Line
Connection
Load
Connection
Catalog
Number
#300 kcmil-#6 Cu/Al (6) #6–#14 Cu/#8Al TBAN63
Volume 7—Logic Control, Operator Interface and Connectivity Solutions CA08100008E—November 2011 www.eaton.com V7-T8-127
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8.3
Terminal Blocks, Fuse Blocks and Fuse Holders
Power Distribution
Technical Data and Specifications
TB Series Power Blocks
Dimensions
Approximate Dimensions in Inches (mm)
CH163 Series Cover
TB Series Power Blocks
Description Specification
Ratings 285A, 600V; UL/CSA
Materials Molded material; black, UL rated 94V-2 thermoplastic
Operating temperature 257°F (125°C)
CHCPDB-1 = 2.1 (53.3)
CHCPDB-2 = 3.72 (94.5)
CHCPDB-3 = 5.34 (135.6)
Textured
Surfaces
Supplied with
(4) #4 Thread-Cutting Screws
Assembled as Shown
4.14
(105.2)
5.37
(136.4)
0.2 x 0.37
(5.1 x 9.4)
Mtg. Slot
4.93
(125.2) 1.68
(42.7)
2.12
(53.8)
0.5
(12.7)
V7-T8-128 Volume 7—Logic Control, Operator Interface and Connectivity Solutions CA08100008E—November 2011 www.eaton.com
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8.4
Terminal Blocks, Fuse Blocks and Fuse Holders
Fuse Blocks and Fuse Holders
Fuse Blocks and Fuse Holders
Contents
Description Page
Fuse Blocks and Fuse Holders
C383 Series Disconnect Fuse Holders . . . . . . . V7-T8-129
C350 Series Fuse Blocks and
W Series Fuse Holders. . . . . . . . . . . . . . . . . . V7-T8-131
Fuse Blocks and Fuse Holders Overview
Product Description
Available in compact finger
safe (C383) and an open
(C350) design. Eaton’s fuse
blocks and holders provide a
simple DIN mounting device
for protection in control
circuits.
Application Description
Fuse holders and blocks
available for Class CC,
midget, H, M and R.
Standards and Certifications
UL listed
CSA certified
(may not apply to all styles)
Volume 7—Logic Control, Operator Interface and Connectivity Solutions CA08100008E—November 2011 www.eaton.com V7-T8-129
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8.4
Terminal Blocks, Fuse Blocks and Fuse Holders
Fuse Blocks and Fuse Holders
C383 Series Fuse Holders
Contents
Description Page
C383 Series Disconnect Fuse Holders
Product Selection . . . . . . . . . . . . . . . . . . . . . . . V7-T8-130
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . V7-T8-130
Technical Data and Specifications . . . . . . . . . . V7-T8-130
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . V7-T8-130
C350 Series Fuse Blocks and
W Series Fuse Holders . . . . . . . . . . . . . . . . . . . . V7-T8-131
C383 Series Disconnect Fuse Holders
Product Description
Eaton’s C383 Series
disconnect fuse holders
offer 600V fused circuit
protection and subsequently
“no load” switching.
These compact disconnects
are designed as components
in switchboards, panels and
control consoles where
positive and safe circuit
protection is required and
where space is at a premium.
The C383 fuse holders
mount directly on standard
TS35 DIN rails.
Features
“Finger-Safe” design
Recessed termination
screws and a fuse
extraction door afford you
IP20 grade protection and
qualify as “finger-safe” per
IEC standards
Easy to adjust position on
rail—Simply unlatch the
DIN rail adapter, slide the
holder to desired position
and relock
Quick change of fuse—
A permanently attached
pivoting fuse door
simplifies and speeds fuse
extraction. No tools or
accessories needed
Class CC model is UL
listed and CSA certified for
branch circuit protection.
Midget models are UL
Recognized and CSA
certified for supplementary
and high-speed protection
Runs cool—The vented
design provides adequate
air flow around the holders
at all times
Self-extinguishing
UL 94-VO rated polyester
material
Standards and Certifications
Rated voltage:
CSA/UL: 600 Vac/Vdc, 30A
IEC (midget only):
690 Vac, 32A
V7-T8-130 Volume 7—Logic Control, Operator Interface and Connectivity Solutions CA08100008E—November 2011 www.eaton.com
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8.4
Terminal Blocks, Fuse Blocks and Fuse Holders
Fuse Blocks and Fuse Holders
Product Selection
Disconnect Fuse Holders
Accessories
Disconnect Fuse Holders
Accessory Details
C383MPCL
Multi-pole connection links
can be used to connect fuse
holders together for multi-
pole applications. Use two
per connection.
C383MPHP
Handle pins can be used to
connect handles in multi-pole
applications.
Technical Data and Specifications
Disconnect Fuse Holders 1
Dimensions
Approximate Dimensions in Inches (mm)
CH163 Series Cover
Notes
1For additional technical information, consult the Eaton web site or Customer Support Center.
2UL recognizes both solid and stranded wire. Ferrules are not required. CSA requires ferrules on stranded wire to achieve approval.
Description Standard Pack Catalog Number
For Class CC Fuse
Single-pole fuse holder 12 C383FHCC
For Midget Fuse (1-1/2 in x 13/32 in)
Single-pole fuse holder 12 C383FHMD
Description Standard Pack Catalog Number
Midget or Class CC Fuse Holder
Multi-pole connection links 100 C383MPCL
Multi-pole handle pins 100 C383MPHP
C383FH_
Description Specification
Housing Polyester UL 94-VO rated
Color White
Wire size 8–18 AWG 2
Torque 22 lb-in (2.5 Nm)
Fuse size 0.41 x 1.5 in
3.07
(78.0)
0.13
(3.2)
1.77
(45.0)
1.40
(35.6)
0.70 (17.8)
2.10 (53.4)
2.40 (61.0)
1.69 (43.0)
2.80 (71.2)
3.13 (79.5)
Volume 7—Logic Control, Operator Interface and Connectivity Solutions CA08100008E—November 2011 www.eaton.com V7-T8-131
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8.4
Terminal Blocks, Fuse Blocks and Fuse Holders
Fuse Blocks and Fuse Holders
C350 Series Fuse Blocks and W Series Fuse Holders
Contents
Description Page
C383 Series Disconnect Fuse Holders . . . . . . . . . V7-T8-129
C350 Series Fuse Blocks and W Series Fuse
Holders
Product Selection . . . . . . . . . . . . . . . . . . . . . . . V7-T8-132
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . V7-T8-133
Technical Data and Specifications . . . . . . . . . . V7-T8-133
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . V7-T8-133
C350 Series Fuse Blocks and W Series Fuse Holders
Product Description
Fuse Blocks
These space-saving Type
C350 Fuse Blocks are UL
approved for motor loads and
are rated 600V, 30A.
Fuse Holders
Class H, M and R
Features
Fuse Blocks
Mount to 35 mm flat
and 32 mm asymmetrical
DIN rails
600V, 30A rated captive
pressure plate terminals
with copper alloy fuse clips
Interlocking fuse blocks
permit single, double or
three-pole application—
reduce inventory
Class CC fuses have an
interrupting rating of
200,000A
Rejection feature prevents
insertion of fuses with
lower interrupting or
voltage ratings
Fuse Holders
Break-resistant: molded of
heat-stabilized nylon
Fuse clips: spring-
reinforced for cool
operation
Fuse clip terminations:
one-piece construction
Universal mounting
dimensions, for easy
assembly and retrofit
Breathing action collar:
maintenance-free
Pressure wire connectors:
vibration resistant
Standards and Certifications
Contact Eaton for the latest
UL 508A short circuit ratings
on terminal blocks.
Fuse Blocks
UL listed
CSA certified
Fuse Holders
UL tested for OEM
subfeed applications
Fuse Blocks and Adapters
Cat. No. C350BD3C61
Three-Pole with Adapter
(Mounted on DIN Rail)
Cat. No. C350B1C61
One-Pole Fuse Blocks
Cat. No. C350KD DIN Rail Adapter
V7-T8-132 Volume 7—Logic Control, Operator Interface and Connectivity Solutions CA08100008E—November 2011 www.eaton.com
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8.4
Terminal Blocks, Fuse Blocks and Fuse Holders
Fuse Blocks and Fuse Holders
Product Selection
Class CC Fuse Blocks
Fuse Holders—250V
Fuse Holders—600V
Note
1 Three-pole device is supplied with DIN rail adapter.
Type
Catalog
Number
Three-pole 1C350BD3C61
Single-pole C350B1C61
DIN adapter C350KD
Wire Termination
Number
of Poles
Carton
Qty.
30A
Carton
Qty.
60A
Catalog
Number
Catalog
Number
Class H Fuse Holders
Single collar (box lug)—
sized to ampere rating
110W231HA 10 W261HA
25W232HA 5W262HA
35W233HA 5W263HA
Class R Fuse Holders
Single collar (box lug)—
sized to ampere rating
110WR231HA
2—
35WR233HA 1WR263HA
Wire Termination
Number
of Poles
Carton
Qty.
30A
Carton
Qty.
60A
Catalog
Number
Catalog
Number
Class H Fuse Holders
Single collar (box lug)—
sized to ampere rating
110W631HA 1W661HA
25W632HA 1W662HA
31W633HA 2W663HA
Class M Fuse Holders
Combination of double quick-connect,
20A max., and binding head screw,
#10 max., Cu/Al
110WM631F
28WM632F
36WM633F
Combination of double quick-connect,
20A max., and pressure plate screw,
#10 max., Cu only
110WM631G
28WM632G
36WM633G
Class R Fuse Holders
Single collar (box lug)—
sized to ampere rating
110WR631HA
25WR632HA
35WR633HA 5WR663HA
Combination of double quick-connect,
20A max., and binding head screw,
#10 max., Cu/Al
1—
21WMR632F
36WMR633F
Combination of double quick-connect,
20A max., and pressure plate screw,
#10 max., Cu only
110WMR631G
36WMR633G
Class R Fuse Holder, Type WRR Control Transformer Fuse Blocks
Combination of double quick-connect,
20A max., and pressure plate screw,
#14–#10 Cu only
36WRR633G
Class R, Three-Pole
Fuse Holder
Volume 7—Logic Control, Operator Interface and Connectivity Solutions CA08100008E—November 2011 www.eaton.com V7-T8-133
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8.4
Terminal Blocks, Fuse Blocks and Fuse Holders
Fuse Blocks and Fuse Holders
Accessories
Fuse Holder Accessories
Technical Data and Specifications
Fuse Blocks
Dimensions
Approximate Dimensions in Inches (mm)
Fuse Blocks
Fuse Holders
Description Catalog Number
Fuse puller TBP
Lighted fuse puller (120 Vac) TBLP
Description Specification
Voltage rating 600V
Ampere rating Pressure plate terminals rated for 30A
Dielectric strength 1200V maximum
Ambient temperature 221°F (105°C) maximum
Clip/terminals Tin-plated copper alloy
Screw and captive pressure plate Zinc-plated steel
Base Thermoplastic UL 94VO flammability rating
DIN rail adapter Thermoplastic UL 94VO flammability rating
Class
Volts/
Amperes
Width A
Height
B
Depth
C
Mounting Holes Number of Mounting Holes
Single-
Pole
Two-
Pole
Three-
Pole D
Two-Pole
D1
Three-Pole
D1 E
Diameter
F
Single-
Pole
Two-
Pole
Three-
Pole
H, R 250V, 30A 1.00 (25.4) 2.00 (50.8) 3.00 (76.2) 3.13 (79.5) 1.56 (39.6) 0.38 (9.7) 1.25 (31.8) 2.50 (63.5) 0.22 (5.6) 2 2 2
250V, 60A 1.44 (36.6) 2.88 (73.2) 4.31 (109.5) 4.75 (120.7) 2.06 (52.3) 0.50 (12.7) 1.81 (46.0) 3.13 (79.5) 1.25 (31.8) 0.22 (5.6) 2 4 4
600V, 30/60A 1.69 (42.9) 3.38 (85.9) 5.06 (128.5) 6.94 (176.3) 2.63 (66.8) 0.63 (16.0) 2.19 (55.6) 3.75 (95.3) 3.13 (79.5) 0.28 (7.1) 2 4 4
M, R 600V, 30A 0.84 (21.3) 1.63 (41.4) 2.41 (61.2) 3.00 (76.2) 1.28 (32.5) 0.38 (9.7) 0.75 (19.1) 1.50 (38.1) 0.17 (4.3) 2 2 2
2.24
(56.9)
3.00
(76.2)
2.35 (59.7)
Three-Pole Width
Three-Pole WidthCatalog No. C350 Fuse Block Catalog No. C350 Fuse Block
with DIN Rail Adapter
1.25
(31.8) 0.78
(19.8)
0.60
(15.2)
CA
Single-
Pole AA
F
Dia. B
DD1D1
Two-
Pole Three-
Pole
Class H & R
250V, 30A
Class M & R
600V, 30A
CA
E
Single-
Pole AA
F
Dia. B
DD1
D
Two-
Pole Three-
Pole
D1
D
E E
Class H & R
250V, 60A
600V, 30/60A
V7-T8-134 Volume 7—Logic Control, Operator Interface and Connectivity Solutions CA08100008E—November 2011 www.eaton.com
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8.4
Terminal Blocks, Fuse Blocks and Fuse Holders
Fuse Blocks and Fuse Holders