Terminal Blocks, Fuse Blocks and Fuse Holders Screw Connection 8.1 IEC--XB Series IEC--XB Series Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Screw Connection Terminal Blocks . . . . . . . . . . . . . . . . . . . . . . . . . . . Spring Cage Terminal Blocks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Pluggable Spring Cage Connection Terminal Blocks. . . . . . . . . . . . . . . IDC Terminal Blocks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Miniature Circuit Breakers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . XB Series Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8.2 Spring Cage V7-T8-58 V7-T8-67 V7-T8-82 V7-T8-90 V7-T8-106 V7-T8-107 V7-T8-111 Power Distribution Power Distribution Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . CHDB Series--Power Distribution Blocks . . . . . . . . . . . . . . . . . . . . . . CH160 Series--Power Terminal Blocks . . . . . . . . . . . . . . . . . . . . . . . . Power Terminal Block Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . 8.4 V7-T8-4 V7-T8-31 NEMA NEMA Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C381 Series Terminal Blocks, Rail Mounted . . . . . . . . . . . . . . . . . . . . TB Series Terminal Blocks, Modular . . . . . . . . . . . . . . . . . . . . . . . . . . . 8.3 V7-T8-2 V7-T8-116 V7-T8-117 V7-T8-123 V7-T8-126 Fuse Blocks and Fuse Holders Fuse Blocks and Fuse Holders Overview . . . . . . . . . . . . . . . . . . . . . . . C383 Series Disconnect Fuse Holders . . . . . . . . . . . . . . . . . . . . . . . . . C350 Series Fuse Blocks and W Series Fuse Holders . . . . . . . . . . . . . V7-T8-128 V7-T8-129 V7-T8-131 Insulation Displacement Connection 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 Learn Online 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 Volume 7--Logic Control, Operator Interface and Connectivity Solutions CA08100008E--November 2011 www.eaton.com V7-T8-1 8.1 8 Terminal Blocks, Fuse Blocks and Fuse Holders IEC--XB Series Contents IEC--XB Series Description 8 Page IEC--XB Series Screw Connection Terminal Blocks . . . . . . . . . Spring Cage Terminal Blocks . . . . . . . . . . . . . . Pluggable Spring Cage Connection Terminal Blocks. . . . . . . . . . . . . . . . . . . . . . . . IDC Terminal Blocks . . . . . . . . . . . . . . . . . . . . . Miniature Circuit Breakers. . . . . . . . . . . . . . . . . XB Series Accessories . . . . . . . . . . . . . . . . . . . 8 8 8 8 V7-T8-4 V7-T8-31 V7-T8-58 V7-T8-67 V7-T8-82 V7-T8-90 8 8 8 8 8 IEC--XB Series Overview 8 Product Description Features The XB Series from Eaton offers a complete terminal block system with a universal range of accessories. Marking, bridging and testing accessories are standardized across the different termination technologies-- reducing inventory and logistics costs. The modular terminal block design allows for use of the different terminal block types together or individually, providing the highest degree of flexibility. Global acceptance--The XB Series terminal blocks are designed to worldwide standards and meet the latest international requirements. 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 Application Description The metal portion of the XB Series terminal blocks are made from high-grade, straincrack and corrosion-proof copper alloys. They won't experience any electrolytic corrosion or rusting, even when moisture is present. The metal surfaces are protected with a lead-free, galvanic nickel or tin plating. The good electrical conductivity permits only a low temperature rise. The Polyamide 6.6 housings allow for operating temperatures up to 257F (125C) and are certified for inflammability Class V0 in accordance with UL 94. Flexible Plug-in bridge system--All three technologies (screw, spring and IDC) use the same bridge system, allowing for individual potential distribution and quickly bridged connections among the same terminal block type or across different types. The XB Series terminal blocks have two bridge shafts arranged in one line, making flexible chain bridging and skip bridging between nonadjacent terminal blocks possible. Plug-in bridges are available from 2 to 50 positions. Reducing bridges are also available to connect a larger terminal block to a smaller one. Standards and Certifications Large surface area for marking--All XB Series terminal blocks have generously sized surface areas for labeling. This allows for clearly labeled wiring that results in reduced startup time and simplifies activities such as testing and maintenance. There are provisions for marking individual terminal blocks and end stops, strips of terminal blocks, and large groups of terminal blocks. Standardized testing system--All test plugs make contact in one of the easily accessible bridge shafts. A 2.3 mm diameter test plug is available for individual measuring wires. Modular test plugs are also available for more advanced testing. UL(R) and cUL(R) recognized--File No. E67464 CE approved LVD 1 EN 60947-7-1 EN 60947-7-2 EN 60998-2-3 EN 60352-4/A1 ATEX approval (Eex e applications) Note 1 Not all standards apply to all terminal blocks. Contact Eaton for details. 8 8 V7-T8-2 Volume 7--Logic Control, Operator Interface and Connectivity Solutions CA08100008E--November 2011 www.eaton.com 8.1 Terminal Blocks, Fuse Blocks and Fuse Holders IEC--XB Series Technical Data and Specifications 8 IEC--XB Series Description Specification Insulation material Polyamide 6.6 Dielectric strength 600 kV/cm Creep resistance 600 CTI Internal insulation resistance 1012 ohms cm Surface resistance 1010 ohms 8 8 8 8 Flammability rating UL 94 V0 Continuous operating temperature -40 to 257F (-40 to 125C) 8 8 Modular Terminal Blocks for Potentially Explosive Environments The standard modular The modular terminal blocks terminal blocks from Eaton are approved for fitting in are approved for potentially Zone 1, the Ex environment, explosive environments. In as well as Zone 2. Zone 1 addition to the usual fitting is conditional upon approvals, they also have terminal blocks being used in been approved by a testing connection boxes approved center authorized by the EU. for EEx e type protection and No extra approval is required having the equivalent of at in Intrinsic Safety type least IP54 protection. applications. The EEx approved modular Modular terminal blocks on terminal blocks can be www.eaton.com fulfill the divided into the following requirements for "Increased groups: Safety" protection type when Screw connection installation instructions are terminal blocks followed, and have a type Spring-cage connection examination certificate terminal blocks in accordance with the Ex directive Ex-RL 94/9/EU. Insulation Displacement Connection terminal blocks These test certificates are Mini terminal blocks recognized in all the EU Terminal blocks for member states and beyond. specialized applications 8 More detailed information on modular terminal blocks in the EEx e area is available on the Internet at www.eaton.com for downloading. 8 8 8 Here you will find the following: 8 Technical data in accordance with EN 50 019 Approved accessories Important installation instructions and mounting diagrams EU type examination certificates General information on Ex protection 8 8 8 8 8 8 8 8 Identifications Explosion protected electrical equipment must be marked so that the safety characteristics are identifiable. The identification of electrical equipment is described in the harmonized standard EN 50014, as shown in the following example: EN 50014 Standard Example Description Identification Manufacturer or trademark Eaton Type designation XBUT25 Abbreviation of explosion protection Identification in Accordance with ATEX-RL Electrical equipment that is certified in accordance with the ATEX 100a guideline also receives identification describing the site for use. ATEX Guideline Example 8 Description Identification Manufacturing data 02.01.2004 Address of the manufacturer Duncan, SC 8 EEx e ll Number of the appointed dept. 344 8 Protection type increased safety "e" e Common marking Ex symbol Equipment group II 8 Equipment group II Category 2 Mark of the testing body KEMA Use in gas and/or dust atmospheres GD Approval number 05ATEX2158 U 8 8 8 8 8 8 Volume 7--Logic Control, Operator Interface and Connectivity Solutions CA08100008E--November 2011 www.eaton.com V7-T8-3 8.1 8 Terminal Blocks, Fuse Blocks and Fuse Holders IEC--XB Series Contents Screw Connection Description 8 Page Screw Connection Terminal Blocks Single Level--Through-Feed . . . . . . . . . . . . . . . Single Level--Ground Blocks . . . . . . . . . . . . . . Multi-Conductor Terminal Blocks . . . . . . . . . . . Multi-Conductor Ground Blocks . . . . . . . . . . . . Double Level . . . . . . . . . . . . . . . . . . . . . . . . . . . Triple Level Sensor/Actuator . . . . . . . . . . . . . . . Fuse Terminal Blocks . . . . . . . . . . . . . . . . . . . . Disconnect and Component Terminal Blocks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . High Current Blocks . . . . . . . . . . . . . . . . . . . . . Mini Screw Connection . . . . . . . . . . . . . . . . . . 8 8 8 8 8 8 V7-T8-5 V7-T8-10 V7-T8-12 V7-T8-14 V7-T8-16 V7-T8-18 V7-T8-21 V7-T8-24 V7-T8-27 V7-T8-29 Drawings Online 8 8 8 Screw Connection Terminal Blocks Overview 8 Product Description Application Description Features The XBUT Series uses a screw connection system that is accepted worldwide and is suitable in most applications. The maintenance-free connection provides the reliability you expect from Eaton. Designed for applications with high demands, the XBUT Series screw terminal block has a maintenance-free wire connection. re-tightening of the terminal screws is not necessary to ensure proper operation. The screw locking technique prevents the screws from backing out. Copper wires can be clamped without pre-treatment or ferrules can be used for splicing protection. Multiple conductors can be connected in the same clamping mechanism, saving space. 8 8 8 8 8 8 8 8 8 Maintenance-free connections Global acceptance Multi-conductor connections Flexible Plug-in bridge system Large surface area for marking Standardized testing system Metal parts made of tinplated copper alloy Standards and Certifications UL and cUL recognized-- File No. E67464 CE approved LVD 1: EN 60947-7-1 EN 60947-7-2 EN 60998-2-3 EN 60352-4/A1 ATEX approval (Eex e applications) Note 1 Not all standards apply to all terminal blocks. Contact Eaton for details. 8 8 8 8 8 8 8 8 8 V7-T8-4 Volume 7--Logic Control, Operator Interface and Connectivity Solutions CA08100008E--November 2011 www.eaton.com Terminal Blocks, Fuse Blocks and Fuse Holders IEC--XB Series 8.1 Contents Single Level--Through-Feed Description Single Level--Through-Feed Product Selection . . . . . . . . . . . . . . . . . . . . . . . Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . Technical Data and Specifications . . . . . . . . . . Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . Single Level--Ground Blocks . . . . . . . . . . . . . . . . Multi-Conductor Terminal Blocks . . . . . . . . . . . . . . Multi-Conductor Ground Blocks . . . . . . . . . . . . . . Double Level. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Triple Level Sensor/Actuator . . . . . . . . . . . . . . . . . Fuse Terminal Blocks . . . . . . . . . . . . . . . . . . . . . . . Disconnect and Component Terminal Blocks . . . . High Current Blocks . . . . . . . . . . . . . . . . . . . . . . . . Mini Screw Connection . . . . . . . . . . . . . . . . . . . . . Page 8 8 V7-T8-6 V7-T8-7 V7-T8-9 V7-T8-9 V7-T8-10 V7-T8-12 V7-T8-14 V7-T8-16 V7-T8-18 V7-T8-21 V7-T8-24 V7-T8-27 V7-T8-29 8 8 8 8 8 8 8 8 8 Single Level--Through-Feed 8 Product Description The XBUT terminal blocks feature a compact design and maintenance-free screw connection. There is a double bridge shaft providing maximum flexibility. The double bridge shaft can accommodate individual chain bridging and step-down bridging from other terminal blocks. There are numerous options for accessories, including those for testing and marking. Terminal blocks are available for wire crosssections ranging from 12 AWG (2.5 mm2) to 2/0 AWG (150 mm2). 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 Volume 7--Logic Control, Operator Interface and Connectivity Solutions CA08100008E--November 2011 www.eaton.com V7-T8-5 8.1 8 8 Terminal Blocks, Fuse Blocks and Fuse Holders IEC--XB Series Product Selection XBUT4 8 Screw Connection Single Level--Through-Feed Terminal Width Maximum Wire Size IEC 60 947-7-1 in V/A/AWG EN 50 019 1 in V/A/AWG UL-cUL Ratings in V/A/AWG 5.2 mm 12 AWG/2.5 mm2 800/32/26-12 750/22/28/26-12 600/20/26-12 Color Standard Pack Catalog Number Gray 50 XBUT25 Blue 50 XBUT25BU Gray 50 XBUT4 Blue 50 XBUT4BU Orange 50 XBUT4OR Yellow 50 XBUT4YE 8 Red 50 XBUT4RD White 50 XBUT4WH 8 Black 50 XBUT4BK Green 50 XBUT4GN Gray 50 XBUT6 Blue 50 XBUT6BU Gray 50 XBUT10 8 Blue 50 XBUT10BU Orange 50 XBUT10OR 8 Yellow 50 XBUT10YE Red 50 XBUT10RD Gray 50 XBUT16 Blue 50 XBUT16BU Gray 50 XBUT35 Blue 50 XBUT35BU 8 6.2 mm 10 AWG/4 mm2 800/41/26-10 750/30/38/26-10 600/30/26-10 8 8 8 8.2 mm 8 AWG/6 mm2 800/57/24-8 750/40/50/24-8 600/50/24-8 8 10.2 mm 6 AWG/10 mm2 1000/76/20-6 750/54/69/20-6 600/65/20-6 8 12 mm 8 16 mm 4 AWG/16 mm2 0 AWG/35 mm2 1000/101/17-4 1000/150/15-0 -- -- 8 600/85/16-4 600/150/14-1/0 Note 1 EU type--examination certificate number: KEMA 05ATEX2158 U. 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 V7-T8-6 Volume 7--Logic Control, Operator Interface and Connectivity Solutions CA08100008E--November 2011 www.eaton.com 8.1 Terminal Blocks, Fuse Blocks and Fuse Holders IEC--XB Series Accessories 8 Screw Connection Single Level--Through-Feed Description Color Number of Positions Standard Pack XBUT25 Catalog Number XBUT4 Catalog Number XBUT6 Catalog Number XBUT10 Catalog Number XBUT16 Catalog Number XBUT35 Catalog Number End cover Gray -- 10 XBACUT10 XBACUT10 XBACUT10 XBACUT10 XBACUT16 1 Partition plate Gray -- 10 XBATUT10 XBATUT10 XBATUT10 XBATUT10 -- -- Plug-in bridge-- for cross connections in the bridge shaft Red 2 10 XBAFBS25 XBAFBS26 XBAFBS28 XBAFBS210 XBAFBS212 XBAFBS216 3 10 XBAFBS35 XBAFBS36 -- -- -- -- 5 10 XBAFBS55 XBAFBS56 -- -- -- -- 10 10 XBAFBS105 XBAFBS106 -- -- -- -- 8 8 8 8 8 8 50 10 XBAFBS505 XBAFBS506 -- -- -- -- Test adapter -- -- 10 XBATSPAI4 XBATSPAI4 XBATSPAI4 -- -- -- 2.3 mm diameter test plug -- -- -- XBATSMPS-_ 1 XBATSMPS-_ 1 -- -- -- -- Modular test plug -- -- 10 XBATSPS5 XBATSPS6 XBATSPS8 -- -- -- Blank marker strip (strip of 10) White -- 10 XBMZB5 2 XBMZB6 2 XBMZB8 2 XBMZB10 2 XBMZB12 2 XBMZB15 2 8 8 8 Notes 1 For ordering information, see Page V7-T8-105. 2 For information on Printed Marking Tag Options, see Page V7-T8-98. 8 For additional accessories, see Page V7-T8-90. 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 Volume 7--Logic Control, Operator Interface and Connectivity Solutions CA08100008E--November 2011 www.eaton.com V7-T8-7 8.1 8 Terminal Blocks, Fuse Blocks and Fuse Holders IEC--XB Series XBUT with Reducing Bridge XBACPU25D12 XBACUT10 8 8 lmax lmax 8 8 XBARBUT10ST XBARBUT10 8 8 8 8 Central Input One-Sided Input XBUT10 XBUT25 XBPU25D12 8 8 Step-Down Bridge with Standard Feed-Through Terminal Blocks Input Pick-Off 8 Terminal Blocks Cross-Section Terminal Blocks Cross-Section AWG (mm2) One-Sided Input Imax 8 XBUT10 6 AWG (10 mm2) XBUT25 12 (2.5) 40 65 XBARBUT10 XBUT4 10 (4) 45 65 XBARBUT10 8 8 8 XBUT16 8 8 8 4 AWG (16 mm2) Bridge Central Input Imax Catalog Number XBPT25 12 (2.5) 40 65 XBARBUT10ST XBPT4 10 (4) 45 65 XBARBUT10ST XBQT15 14 (1.5) 35 65 XBARBUT10ST XBQT25 12 (2.5) 40 65 XBARBUT10ST XBUT25 12 (2.5) 40 80 XBARBUT16 XBUT4 10 (4) 45 90 XBARBUT16 XBPT25 12 (2.5) 40 80 XBARBUT16ST XBPT4 10 (4) 45 90 XBARBUT16ST XBQT15 14 (1.5) 35 70 XBARBUT16ST XBQT25 12 (2.5) 40 80 XBARBUT16ST 8 8 8 8 8 8 8 8 8 8 8 V7-T8-8 Volume 7--Logic Control, Operator Interface and Connectivity Solutions CA08100008E--November 2011 www.eaton.com 8.1 Terminal Blocks, Fuse Blocks and Fuse Holders IEC--XB Series Technical Data and Specifications 8 Screw Connection Single Level--Through-Feed Description 8 XBUT25 XBUT4 XBUT6 XBUT10 XBUT16 XBUT35 Maximum load current in A/cross-section in mm2 32/4 41/6 57/10 76/16 101/25 150/50 Rated surge voltage in kV/contamination class 8/3 8/3 8/3 8/3 8/3 8/3 Surge voltage category/insulating material group III/II III/I III/I III/I III/I III/I 0.25-2.5/0.25-2.5 0.25-4/0.25-4 0.25-6/0.25-6 0.5-10/0.5-10 1.0-16/1.0-16 1.5-35/1.5-35 8 Technical Data in Accordance with IEC 8 8 Connection Capacity Stranded with ferrule/with ferrule and plastic sleeve in mm2 Multi-Conductor Connection (same cross-section) 8 8 Solid/stranded in mm2 0.14-1.5/0.14-1.5 0.14-1.5/0.14-1.5 0.2-2.5/0.2-2.5 0.5-4/0.5-4 1.0-6/1.0-4 1.5-16/1.5-10 Stranded with ferrules without plastic sleeve in mm2 0.25-1.5 0.25-1.5 0.25-1.5 0.5-2.5 1.0-4 1.5-10 Stranded with twin ferrule with plastic sleeve in mm2 8 8 0.5-1.5 0.5-2.5 0.5-4 0.5-6 0.75-10 1.5-10 Stripping length in inches (mm) 0.35 (9) 0.35 (9) 0.39 (10) 0.39 (10) 0.39 (10) 0.63 (16) Thread M3 M3 M4 M4 M5 M6 Torque in in-lb (Nm) 5.3-7.1 (0.6-0.8) 5.3-7.1 (0.6-0.8) 13.3-15.9 (1.5-1.8) 13.3-15.9 (1.5-1.8) 22.1-26.6 (2.5-3) 28.3-32.7 (3.2-3.7) 8 8 8 Dimensions Approximate Dimensions in Inches (mm) 8 Screw Connection Single Level--Through-Feed Catalog Number Width XBUT25 0.20 (5.2) 8 Height for-- Length Cover Width 35 x 7.5 in 35 x 15 in 1.85 (46.9) 0.09 (2.2) 1.87 (47.5) 2.17 (55.0) XBUT4 0.24 (6.2) 1.85 (46.9) 0.09 (2.2) 1.87 (47.5) 2.17 (55.0) XBUT6 0.32 (8.2) 1.85 (46.9) 0.09 (2.2) 1.87 (47.5) 2.17 (55.0) XBUT10 0.40 (10.2) 1.85 (46.9) 0.09 (2.2) 1.87 (47.5) 2.17 (55.0) XBUT16 0.47 (12.0) 2.08 (52.8) 0.09 (2.2) 2.16 (54.8) 2.45 (62.3) XBUT35 0.63 (16.0) 2.37 (60.2) -- 2.59 (65.7) 2.88 (73.2) 8 8 8 8 8 Notes 1 XBUT35 has an enclosed design. The use of an end cover is not required. 2 For information on Printed Marking Tag Options, see Page V7-T8-98. 8 8 8 8 8 8 8 8 8 8 8 Volume 7--Logic Control, Operator Interface and Connectivity Solutions CA08100008E--November 2011 www.eaton.com V7-T8-9 8.1 8 Terminal Blocks, Fuse Blocks and Fuse Holders IEC--XB Series Contents Single Level--Ground Blocks Description 8 Page Single Level--Through-Feed . . . . . . . . . . . . . . . . . Single Level--Ground Blocks Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . Technical Data and Specifications . . . . . . . . . . Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . Multi-Conductor Terminal Blocks . . . . . . . . . . . . . Multi-Conductor Ground Blocks . . . . . . . . . . . . . . Double Level . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Triple Level Sensor/Actuator . . . . . . . . . . . . . . . . . Fuse Terminal Blocks . . . . . . . . . . . . . . . . . . . . . . . Disconnect and Component Terminal Blocks . . . . High Current Blocks . . . . . . . . . . . . . . . . . . . . . . . Mini Screw Connection . . . . . . . . . . . . . . . . . . . . . 8 8 8 8 8 8 V7-T8-5 V7-T8-11 V7-T8-11 V7-T8-11 V7-T8-12 V7-T8-14 V7-T8-16 V7-T8-18 V7-T8-21 V7-T8-24 V7-T8-27 V7-T8-29 8 8 8 Single Level--Ground Blocks 8 Product Description 8 8 The ground terminal blocks have the same shape and pitch as the standard terminal block, in a green-yellow housing. They easily snap onto the DIN rail to make a reliable mechanical and electrical contact that meets all requirements of IEC 60947-7-2. 8 8 8 Product Selection XBUT6PE Screw Connection Single Level--Ground Blocks Terminal Width Maximum Wire Size IEC 60 947-7-1 in V/A/AWG EN 50 019 1 in V/A/AWG UL-cUL Ratings in V/A/AWG Color 5.2 mm 12 AWG/2.5 mm2 --/--/26-12 --/--/26-12 --/--/26-12 Green/Yellow 50 XBUT25PE 8 6.2 mm 10 AWG/4 mm2 --/--/26-10 --/--/26-10 --/--/26-10 Green/Yellow 50 XBUT4PE 8.2 mm 8 AWG/6 mm2 --/--/24-8 --/--/24-8 --/--/24-8 Green/Yellow 50 XBUT6PE 8 10.2 mm 6 AWG/10 mm2 --/76/20-6 --/54/69/20-6 --/--/20-6 Green/Yellow 50 XBUT10PE 12 mm 4 AWG/16 mm2 --/101/15-4 -- --/--/16-4 Green/Yellow 50 XBUT16PE 16 mm 2 AWG/35 mm2 --/125/15-2 -- --/--/14-1/0 Green/Yellow 50 XBUT35PE 8 8 Standard Pack Catalog Number Note 1 EU type--examination certificate number: KEMA 05ATEX2158 U. 8 8 8 8 8 8 8 8 8 V7-T8-10 Volume 7--Logic Control, Operator Interface and Connectivity Solutions CA08100008E--November 2011 www.eaton.com 8.1 Terminal Blocks, Fuse Blocks and Fuse Holders IEC--XB Series Accessories 8 Screw Connection Single Level--Ground Blocks Standard Pack XBUT25PE Catalog Number XBUT4PE Catalog Number XBUT6PE Catalog Number XBUT10PE Catalog umber XBUT16PE Catalog Number XBUT35PE Catalog Number 10 XBACUT10 XBACUT10 XBACUT10 XBACUT10 XBACUT16 3 Description Color Number of Positions End cover Gray -- Partition plate -- -- 10 XBATUT10 XBATUT10 XBATUT10 XBATUT10 -- -- Plug-in bridge-- for cross connections in the bridge shaft Red 2 10 XBAFBS25 XBAFBS26 XBAFBS28 XBAFBS210 XBAFBS212 XBAFBS212 3 10 XBAFBS35 XBAFBS36 -- -- -- -- 5 10 XBAFBS55 XBAFBS56 -- -- -- -- 10 10 XBAFBS105 XBAFBS106 -- -- -- -- 50 10 XBAFBS505 XBAFBS506 -- -- -- -- Test adapter -- -- 10 XBATSPAI4 XBATSPAI4 XBATSPAI4 -- -- -- 8 8 8 8 8 8 8 2.3 mm diameter test plug -- -- -- XBATSMPS-_ 1 XBATSMPS-_ 1 -- -- -- -- Modular test plug -- -- 10 XBATSPS5 XBATSPS6 XBATSPS8 -- -- -- Blank marker strip (strip of 10) White -- 10 XBMZB5 2 XBMZB6 2 XBMZB8 2 XBMZB10 2 XBMZB12 2 XBMZB15 2 8 8 Technical Data and Specifications 8 Screw Connection Single Level--Ground Blocks Description XBUT25PE XBUT4PE XBUT6PE XBUT10PE XBUT16PE XBUT35PE Maximum load current in A/cross-section in mm2 -- -- -- 76/16 101/25 125/50 Rated surge voltage in kV/contamination class 8/3 8/3 8/3 8/3 8/3 8/3 Surge voltage category/insulating material group III/II III/I III/I III/I III/I III/I 0.25-2.5/0.25-2.5 0.25-4/0.25-4 0.25-6/0.25-6 0.5-10/0.5-10 1.0-16/1.0-16 1.5-35/1.5-35 Solid/stranded in mm2 0.14-1.5/0.14-1.5 0.14-1.5/0.14-1.5 0.2-2.5/0.2-2.5 0.5-4/0.5-4 1.0-6/1.0-4 1.5-16/1.5-10 Stranded with ferrules without plastic sleeve in mm2 0.25-1.5 0.25-1.5 0.25-1.5 0.5-2.5 1.0-4 1.5-10 Stranded with twin ferrule with plastic sleeve in mm2 0.5-1.5 0.5-2.5 0.5-4 0.5-6 0.75-10 1.5-10 Stripping length in inches (mm) 0.35 (9) 0.35 (9) 0.39 (10) 0.39 (10) 0.39 (10) 0.63 (16) Thread M3 M3 M4 M4 M5 M6 Torque in in-lb (Nm) 5.3-7.1 (0.6-0.8) 5.3-7.1 (0.6-0.8) 13.3-15.9 (1.5-1.8) 13.3-15.9 (1.5-1.8) 22.1-26.6 (2.5-3) 28.3-32.7 (3.2-3.7) Technical Data in Accordance with IEC 8 8 8 8 Connection Capacity Stranded with ferrule/with ferrule and plastic sleeve in mm2 Multi-Conductor Connection (same cross-section) 8 8 8 8 8 8 Dimensions 8 Approximate Dimensions in Inches (mm) 8 Screw Connection Single Level--Ground Blocks Catalog Number Width Height for-- Length Cover Width 35 x 7.5 in 35 x 15 in XBUT25PE 0.20 (5.2) 1.85 (46.9) 0.09 (2.2) 1.87 (47.5) 2.17 (55.0) XBUT4PE 0.24 (6.2) 1.85 (46.9) 0.09 (2.2) 1.87 (47.5) 2.17 (55.0) XBUT6PE 0.32 (8.2) 1.85 (46.9) 0.09 (2.2) 1.87 (47.5) 2.17 (55.0) XBUT10PE 0.40 (10.2) 1.85 (46.9) 0.09 (2.2) 1.87 (47.5) 2.17 (55.0) XBUT16PE 0.47 (12.0) 2.08 (52.8) 0.09 (2.2) 2.16 (54.8) 2.45 (62.3) XBUT35PE 0.63 (16.0) 2.37 (60.2) -- 2.59 (65.7) 2.88 (73.2) 8 8 8 8 8 Notes 1 For ordering information, see Page V7-T8-105. 2 For information on Printed Marking Tag Options, see Page V7-T8-98. 3 XBUT35PE has an enclosed design. The use of an end cover is not required. 8 8 For additional accessories, see Page V7-T8-90. Volume 7--Logic Control, Operator Interface and Connectivity Solutions CA08100008E--November 2011 www.eaton.com V7-T8-11 8.1 8 Terminal Blocks, Fuse Blocks and Fuse Holders IEC--XB Series Contents Multi-Conductor Terminal Blocks Description 8 Page Single Level--Through-Feed . . . . . . . . . . . . . . . . . Single Level--Ground Blocks . . . . . . . . . . . . . . . . Multi-Conductor Terminal Blocks Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . Technical Data and Specifications . . . . . . . . . . Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . Multi-Conductor Ground Blocks . . . . . . . . . . . . . . Double Level . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Triple Level Sensor/Actuator . . . . . . . . . . . . . . . . . Fuse Terminal Blocks . . . . . . . . . . . . . . . . . . . . . . . Disconnect and Component Terminal Blocks . . . . High Current Blocks . . . . . . . . . . . . . . . . . . . . . . . Mini Screw Connection . . . . . . . . . . . . . . . . . . . . . 8 8 8 8 8 8 V7-T8-5 V7-T8-10 V7-T8-13 V7-T8-13 V7-T8-13 V7-T8-14 V7-T8-16 V7-T8-18 V7-T8-21 V7-T8-24 V7-T8-27 V7-T8-29 8 8 8 Multi-Conductor Terminal Blocks 8 Product Description 8 8 8 The multi-conductor terminal blocks offer a space-saving alternative to standard feedthrough terminal blocks allowing for high density wiring. Often, three 8 Product Selection 8 XBUT25D12 8 8 The XBUT...D22 terminal blocks allow four wires to be connected to one potential-- and can therefore be used as compact power distributors. Screw Connection Multi-Conductor Terminal Blocks, Three-Wire Terminal Width Maximum Wire Size IEC 60 947-7-1 in V/A/AWG UL-cUL Ratings in V/A/AWG 5.2 mm 12 AWG/2.5 mm2 500/28/26-12 150/20/26-12 6.2 mm 8 connections have to be led to one terminal block. The XBUT...D12 terminal block accomplishes this without any additional terminal blocks or bridging required. 10 AWG/4 mm2 500/39/26-10 150/30/26-10 Color Standard Pack Catalog Number Gray 50 XBUT25D12 Blue 50 XBUT25D12BU Gray 50 XBUT4D12 Blue 50 XBUT4D12BU 8 8 XBUT4D22 8 Screw Connection Multi-Conductor Terminal Blocks, Four-Wire Terminal Width Maximum Wire Size IEC 60 947-7-1 in V/A/AWG UL-cUL Ratings in V/A/AWG Color Standard Pack Catalog Number 5.2 mm 12 AWG/2.5 mm2 500/28/26-12 150/20/26-12 Gray 50 XBUT25D22 Blue 50 XBUT25D22BU 6.2 mm 10 AWG/4 mm2 500/39/26-10 150/30/26-10 Gray 50 XBUT4D22 Blue 50 XBUT4D22BU 8 8 8 8 8 8 8 V7-T8-12 Volume 7--Logic Control, Operator Interface and Connectivity Solutions CA08100008E--November 2011 www.eaton.com 8.1 Terminal Blocks, Fuse Blocks and Fuse Holders IEC--XB Series Accessories 8 Screw Connection Multi-Conductor Terminal Blocks XBUT4D12 Catalog Number XBUT25D22 Catalog Number XBUT4D22 Catalog Number 8 Description Color Number of Positions Standard Pack XBUT25D12 Catalog Number End cover Gray -- 10 XBACUT4D12 XBACUT4D12 XBACUT4D22 XBACUT4D22 End cover segment Gray -- 10 XBASUT4 XBASUT4 XBASUT4 XBASUT4 8 Partition plate -- -- 10 XBATUTD12 XBATUTD12 XBATUTD22 XBATUTD22 Plug-in bridge--for cross connections in the bridge shaft Red 2 10 XBAFBS25 XBAFBS26 XBAFBS25 XBAFBS26 3 10 XBAFBS35 XBAFBS36 XBAFBS35 XBAFBS36 5 10 XBAFBS55 XBAFBS56 XBAFBS55 XBAFBS56 10 10 XBAFBS105 XBAFBS106 XBAFBS105 XBAFBS106 50 10 XBAFBS505 XBAFBS506 XBAFBS505 XBAFBS506 -- -- 10 XBATSPAI4 XBATSPAI4 XBATSPAI4 XBATSPAI4 2.3 mm diameter test plug -- -- -- XBATSMPS-_ 1 XBATSMPS-_ 1 XBATSMPS-_ 1 XBATSMPS-_ 1 Modular test plug -- -- 10 XBATSPS5 XBATSPS6 XBATSPS5 XBATSPS6 10 2 2 2 2 White -- XBMZB5 XBMZB6 XBMZB5 XBMZB6 8 8 Test adapter Blank marker strip (strip of 10) 8 8 8 8 8 Technical Data and Specifications 8 Screw Connection Multi-Conductor Terminal Blocks 8 Description XBUT25D12 XBUT4D12 XBUT25D22 XBUT4D22 8 Technical Data in Accordance with IEC Maximum load current in A/cross-section in mm2 28/4 39/6 28/4 39/6 Rated surge voltage in kV/contamination class 6/3 6/3 6/3 6/3 Surge voltage category/insulating material group III/I III/I III/I III/I 0.25-2.5/0.25-2.5 0.25-4/0.25-4 0.25-2.5/0.25-2.5 0.25-4/0.25-4 8 8 Connection Capacity Stranded with ferrule/with ferrule and plastic sleeve in mm2 8 8 Multi-Conductor Connection (same cross-section) Solid/stranded in mm2 0.14-1.0/0.14-1.0 0.14-1.0/0.14-1.5 0.14-1.0/0.14-1.0 0.14-1/0.14-1.5 Stranded with ferrules without plastic sleeve in mm2 0.25-1.0 0.25-1.5 0.25-1.0 0.25-1.5 Stranded with twin ferrule with plastic sleeve in mm2 0.5-1.0 0.5-1.0 0.5-1.0 0.5-1.0 Stripping length in inches (mm) 0.31 (8) 0.31 (8) 0.31 (8) 0.31 (8) Thread M3 M3 M3 M3 Torque in in-lb (Nm) 5.3-7.1 (0.6-0.8) 5.3-7.1 (0.6-0.8) 5.3-7.1 (0.6-0.8) 5.3-7.1 (0.6-0.8) 8 8 8 8 8 Dimensions Approximate Dimensions in Inches (mm) 8 Screw Connection Multi-Conductor Terminal Blocks 8 Catalog Number Width Length Cover Width Height for-- 35 x 7.5 in 8 35 x 15 in XBUT25D12 0.20 (5.2) 2.24 (56.8) 0.09 (2.2) 1.87 (47.5) 2.17 (55.0) XBUT4D12 0.24 (6.2) 2.24 (56.8) 0.09 (2.2) 1.87 (47.5) 2.17 (55.0) XBUT25D22 0.20 (5.2) 2.52 (64.1) 0.09 (2.2) 1.87 (47.5) 2.17 (55.0) XBUT4D22 0.24 (6.2) 2.52 (64.1) 0.09 (2.2) 1.87 (47.5) 2.17 (55.0) 8 8 8 Notes 1 For ordering information, see Page V7-T8-105. 2 For information on Printed Marking Tag Options, see Page V7-T8-98. 8 For additional accessories, see Page V7-T8-90. Volume 7--Logic Control, Operator Interface and Connectivity Solutions CA08100008E--November 2011 www.eaton.com 8 V7-T8-13 8.1 8 Terminal Blocks, Fuse Blocks and Fuse Holders IEC--XB Series Contents Multi-Conductor Ground Blocks Description 8 Page Single Level--Through-Feed . . . . . . . . . . . . . . . . . Single Level--Ground Blocks . . . . . . . . . . . . . . . . Multi-Conductor Terminal Blocks . . . . . . . . . . . . . Multi-Conductor Ground Blocks Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . Technical Data and Specifications . . . . . . . . . . Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . Double Level . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Triple Level Sensor/Actuator . . . . . . . . . . . . . . . . . Fuse Terminal Blocks . . . . . . . . . . . . . . . . . . . . . . . Disconnect and Component Terminal Blocks . . . . High Current Blocks . . . . . . . . . . . . . . . . . . . . . . . Mini Screw Connection . . . . . . . . . . . . . . . . . . . . . 8 8 8 8 8 8 V7-T8-5 V7-T8-10 V7-T8-12 V7-T8-15 V7-T8-15 V7-T8-15 V7-T8-16 V7-T8-18 V7-T8-21 V7-T8-24 V7-T8-27 V7-T8-29 8 8 8 Multi-Conductor Ground Blocks 8 Product Description 8 8 The ground terminal blocks have the same shape and pitch as the standard terminal block, in a green-yellow housing. They easily snap onto the DIN rail to make a reliable mechanical and electrical contact that meets all requirements of IEC 60-947-7-2. 8 8 Product Selection 8 XBUT4D12PE 8 8 Screw Connection Multi-Conductor Ground Blocks--Three-Wire Terminal Width Maximum Wire Size IEC 60 947-7-1 in V/A/AWG UL-cUL Ratings in V/A/AWG Color Standard Pack Catalog Number 5.2 mm 12 AWG/2.5 mm2 --/--/26-12 --/--/26-12 Green/Yellow 50 XBUT25D12PE 6.2 mm 10 AWG/4 mm2 --/--/26-10 --/--/26-10 Green/Yellow 50 XBUT4D12PE 8 8 8 8 XBUT25D22PE 8 8 Screw Connection Multi-Conductor Ground Blocks--Four-Wire Terminal Width Maximum Wire Size IEC 60 947-7-1 in V/A/AWG UL-cUL Ratings in V/A/AWG Color Standard Pack Catalog Number 5.2 mm 12 AWG/2.5 mm2 --/--/26-12 --/--/26-12 Green/Yellow 50 XBUT25D22PE 6.2 mm 10 AWG/4 mm2 --/--/26-10 --/--/26-10 Green/Yellow 50 XBUT4D22PE 8 8 8 8 8 V7-T8-14 Volume 7--Logic Control, Operator Interface and Connectivity Solutions CA08100008E--November 2011 www.eaton.com 8.1 Terminal Blocks, Fuse Blocks and Fuse Holders IEC--XB Series Accessories 8 Screw Connection Multi-Conductor Ground Blocks Description Color Number of Positions Standard Pack XBUT25D12PE Catalog Number XBUT4D12PE Catalog Number XBUT25D22PE Catalog Number XBUT4D22PE Catalog Number End cover Gray -- 10 XBACUT4D12 XBACUT4D12 XBACUT4D22 XBACUT4D22 End cover segment Gray -- 10 XBASUT4 XBASUT4 XBASUT4 XBASUT4 Partition plate -- -- 10 XBATUTD12 XBATUTD12 XBATUTD22 XBATUTD22 Plug-in bridge--for cross connections in the bridge shaft Red 2 10 XBAFBS25 XBAFBS26 XBAFBS25 XBAFBS26 3 10 XBAFBS35 XBAFBS36 XBAFBS35 XBAFBS36 5 10 XBAFBS55 XBAFBS56 XBAFBS55 XBAFBS56 10 10 XBAFBS105 XBAFBS106 XBAFBS105 XBAFBS106 50 10 XBAFBS505 XBAFBS506 XBAFBS505 XBAFBS506 -- -- 10 XBATSPAI4 XBATSPAI4 XBATSPAI4 XBATSPAI4 2.3 mm diameter test plug -- -- -- XBATSMPS-_ 1 XBATSMPS-_ 1 XBATSMPS-_ 1 XBATSMPS-_ 1 Modular test plug -- -- 10 XBATSPS5 XBATSPS6 XBATSPS5 XBATSPS6 10 2 2 XBMZB5 2 2 White -- XBMZB5 XBMZB6 XBMZB6 8 8 8 8 Test adapter Blank marker strip (strip of 10) 8 8 8 8 8 Technical Data and Specifications 8 Screw Connection Multi-Conductor Ground Blocks 8 Description XBUT25D12PE XBUT4D12PE XBUT25D22PE XBUT4D22PE 8 Technical Data in Accordance with IEC Maximum load current in A/cross-section in mm2 -- -- -- -- Rated surge voltage in kV/contamination class 6/3 6/3 6/3 6/3 Surge voltage category/insulating material group III/I III/I III/I III/I 0.25-2.5/0.25-2.5 0.25-4/0.25-4 0.25-2.5/0.25-2.5 0.25-4/0.25-4 8 8 Connection Capacity Stranded with ferrule/with ferrule and plastic sleeve in mm2 8 8 Multi-Conductor Connection (same cross-section) Solid/stranded in mm2 0.14-1.0/0.14-1.0 0.14-1.0/0.14-1.5 0.14-1.0/0.14-1.0 0.14-1.0/0.14-1.5 Stranded with ferrules without plastic sleeve in mm2 0.25-1.0 0.25-1.5 0.25-1.0 0.25-1.5 Stranded with twin ferrule with plastic sleeve in mm2 0.5-1.0 0.5-1.0 0.5-1 0.5-1 Stripping length in inches (mm) 0.31 (8) 0.31 (8) 0.31 (8) 0.31 (8) Thread M3 M3 M3 M3 Torque in in-lb (Nm) 5.3-7.1 (0.6-0.8) 5.3-7.1 (0.6-0.8) 5.3-7.1 (0.6-0.8) 5.3-7.1 (0.6-0.8) 8 8 8 8 8 Dimensions Approximate Dimensions in Inches (mm) 8 Screw Connection Multi-Connector Ground Blocks 8 Catalog Number Width Cover Width Height for-- Length 35 x 7.5 in 35 x 15 in XBUT25D12PE 0.20 (5.2) 2.24 (56.8) 0.09 (2.2) 1.87 (47.5) 2.17 (55.0) XBUT4D12PE 0.20 (5.2) 2.24 (56.8) 0.09 (2.2) 1.87 (47.5) 2.17 (55.0) XBUT25D22PE 0.20 (5.2) 2.52 (64.1) 0.09 (2.2) 1.87 (47.5) 2.17 (55.0) XBUT4D22PE 0.24 (6.2) 2.52 (64.1) 0.09 (2.2) 1.87 (47.5) 2.17 (55.0) 8 8 8 8 Notes 1 For ordering information, see Page V7-T8-105. 2 For information on Printed Marking Tag Options, see Page V7-T8-98. 8 For additional accessories, see Page V7-T8-90. Volume 7--Logic Control, Operator Interface and Connectivity Solutions CA08100008E--November 2011 www.eaton.com 8 V7-T8-15 8.1 8 Terminal Blocks, Fuse Blocks and Fuse Holders IEC--XB Series Contents Double Level Description 8 Page Single Level--Through-Feed . . . . . . . . . . . . . . . . . Single Level--Ground Blocks . . . . . . . . . . . . . . . . Multi-Conductor Terminal Blocks . . . . . . . . . . . . . Multi-Conductor Ground Blocks . . . . . . . . . . . . . . Double Level Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . Technical Data and Specifications . . . . . . . . . . Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . Triple Level Sensor/Actuator . . . . . . . . . . . . . . . . . Fuse Terminal Blocks . . . . . . . . . . . . . . . . . . . . . . . Disconnect and Component Terminal Blocks . . . . High Current Blocks . . . . . . . . . . . . . . . . . . . . . . . Mini Screw Connection . . . . . . . . . . . . . . . . . . . . . 8 8 8 8 8 8 V7-T8-5 V7-T8-10 V7-T8-12 V7-T8-14 V7-T8-17 V7-T8-17 V7-T8-17 V7-T8-18 V7-T8-21 V7-T8-24 V7-T8-27 V7-T8-29 8 8 8 Double Level 8 Product Description 8 8 The potentials of the XBUTT double-level terminal blocks are on two levels to reduce space requirements by 50% over single-level terminal blocks. The XBUTT Series can be bridged on both levels for maximum flexibility. Marking can be provided at each termination point. 8 8 Product Selection 8 XBUTT4 Screw Connection Double Level Blocks, XBUTT4 Terminal Width 8 Maximum Wire Size IEC 60 947-7-1 in V/A/AWG UL-cUL Ratings in V/A/AWG Color Standard Pack Catalog Number Screw Connection Double Level Blocks 8 6.2 mm 10 AWG/4 mm2 800/36/26-10 300/30/26-10 Gray 50 XBUTT4 Blue 50 XBUTT4BU Red 50 XBUTT4RD Gray 50 XBUTT4PV UL-cUL Ratings in V/A/AWG Color Standard Pack Catalog Number --/--/26-10 Green/Yellow 50 XBUTT4PE 8 8 Screw Connection Double Level Block (terminal block with potential distribution between the levels) 6.2 mm 10 AWG/4 mm2 800/36/26-10 300/30/26-10 8 8 XBUTT4PE Screw Connection Double Level Ground Block, XBUTT4PE Terminal Width 8 Maximum Wire Size IEC 60 947-7-1 in V/A/AWG Screw Connection Double Level--Ground Blocks 8 6.2 mm 10 AWG/4 mm2 --/--/26-10 8 8 8 8 8 V7-T8-16 Volume 7--Logic Control, Operator Interface and Connectivity Solutions CA08100008E--November 2011 www.eaton.com Terminal Blocks, Fuse Blocks and Fuse Holders IEC--XB Series 8.1 Accessories 8 Screw Connection Terminal/Ground Blocks, Double Level Description Color Number of Positions Standard Pack XBUTT4 Catalog Number XBUTT4PE Catalog Number End cover Gray -- 10 XBACUTT4 XBACUTT4 End cover segment Gray -- 10 XBDPUTT4 XBDPUTT4 Partition plate -- -- 10 XBATUTT4 XBATUTT4 Plug-in bridge--for cross connections in the bridge shaft Red 2 10 XBAFBS26 XBAFBS26 3 10 XBAFBS36 XBAFBS36 5 10 XBAFBS56 XBAFBS56 10 10 XBAFBS106 XBAFBS106 50 10 XBAFBS506 XBAFBS506 Test adapter -- -- 10 XBATSPAI4 XBATSPAI4 2.3 mm diameter test plug -- -- -- XBATSMPS-_ 1 XBATSMPS-_ 1 Modular test plug -- -- 10 XBATSPS6 XBATSPS6 10 2 2 Blank marker strip (strip of 10) White -- XBMZB6 XBMZB6 8 8 8 8 8 8 8 8 8 Technical Data and Specifications 8 Screw Connection Double Level 8 Description XBUTT4 XBUTT4PE 8 Technical Data in Accordance with IEC Maximum load current in A/cross-section in mm2 30/6 --/6 Rated surge voltage in kV/contamination class 8/3 6/3 Surge voltage category/insulating material group III/I III/I 0.25-4/0.25-4 0.25-4/0.25-4 8 8 Connection Capacity Stranded with ferrule/with ferrule and plastic sleeve in mm2 8 8 Multi-Conductor Connection (same cross-section) Solid/stranded in mm2 0.14-1.5/0.14-1.5 0.14-1.5/0.14-1.5 Stranded with ferrules without plastic sleeve in mm2 0.25-1.5 0.25-1.5 Stranded with twin ferrule with plastic sleeve in mm2 0.5-2.5 0.5-2.5 Stripping length in inches (mm) 0.35 (9) 0.35 (9) Thread M3 M3 Torque in in-lb (Nm) 5.3-7.1 (0.6-0.8) 5.3-7.1 (0.6-0.8) 8 8 8 8 8 Dimensions Approximate Dimensions in Inches (mm) 8 Screw Connection Double Level 8 Length Cover Width Height for-- Width 35 x 7.5 in 35 x 15 in XBUTT4 0.24 (6.2) 2.75 (69.9) 0.09 (2.2) 2.56 (65.0) 2.85 (72.5) XBUTT4PE 0.24 (6.2) 2.75 (69.9) 0.09 (2.2) 2.56 (65.0) 2.85 (72.5) Catalog Number 8 8 8 Notes 1 For ordering information, see Page V7-T8-105. 2 For information on Printed Marking Tag Options, see Page V7-T8-98. 8 For additional accessories, see Page V7-T8-90. 8 8 Volume 7--Logic Control, Operator Interface and Connectivity Solutions CA08100008E--November 2011 www.eaton.com V7-T8-17 8.1 8 Terminal Blocks, Fuse Blocks and Fuse Holders IEC--XB Series Contents Triple Level Sensor/Actuator Description 8 Page Single Level--Through-Feed . . . . . . . . . . . . . . . . . Single Level--Ground Blocks . . . . . . . . . . . . . . . . Multi-Conductor Terminal Blocks . . . . . . . . . . . . . Multi-Conductor Ground Blocks . . . . . . . . . . . . . . Double Level . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Triple Level Sensor/Actuator Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . Technical Data and Specifications . . . . . . . . . . Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . Fuse Terminal Blocks . . . . . . . . . . . . . . . . . . . . . . . Disconnect and Component Terminal Blocks . . . . High Current Blocks . . . . . . . . . . . . . . . . . . . . . . . Mini Screw Connection . . . . . . . . . . . . . . . . . . . . . 8 8 8 8 8 8 V7-T8-5 V7-T8-10 V7-T8-12 V7-T8-14 V7-T8-16 V7-T8-19 V7-T8-20 V7-T8-20 V7-T8-21 V7-T8-24 V7-T8-27 V7-T8-29 8 8 8 Triple Level Sensor/Actuator 8 Product Description 8 8 8 8 8 The XB3UK sensor terminal blocks reduce installation time by terminating threewire devices such as photoelectric and proximity sensors in a single terminal block. The XB3UK Series accommodates a design where the positive and negative connections are 8 Product Selection 8 XB3UKA25 bridged. These are used for the sensor power supply. The positive and negative potential can be fed into the bridges with XB3UKF25. The first sensor can also be connected to this three-wire feed-through block. Screw Connection Triple Level Sensor/Actuator Terminal Width 8 grouped so that only the signal lines and one pair of wires for the power supply need to be wired between the terminal box and the control. The upper level accommodates the markable feed-through terminals for the signal line. The two lower terminal points can be Maximum Wire Size Connection Data in V/A/AWG IEC 60 947-7-1 in V/A/AWG UL-cUL Ratings in V/A/AWG Color Standard Pack Catalog Number 250/26/24-12 -- 300/15/30-14 Gray 50 XB3UKA25 300/15/30-14 Gray 50 XB3UKA25L24 Screw Connection Triple Level 8 6.2 mm 14 AWG/2.5 mm2 Screw Connection Triple Level with Red LED, 15-30 Vdc, 2.5-7.5A 8 6.2 mm 14 AWG/2.5 mm2 250/26/24-12 -- 8 8 8 XB3UKF25 Screw Connection Triple Level Sensor/Actuator Terminal Width 8 Maximum Wire Size Connection Data in V/A/AWG IEC 60 947-7-1 in V/A/AWG UL-cUL Ratings in V/A/AWG Color Standard Pack Catalog Number -- 250/30/24-12 300/15/30-14 Gray 50 XB3UKF25 Screw Connection Triple Level 8 6.2 mm 14 AWG/2.5 mm2 8 8 8 V7-T8-18 Volume 7--Logic Control, Operator Interface and Connectivity Solutions CA08100008E--November 2011 www.eaton.com Terminal Blocks, Fuse Blocks and Fuse Holders IEC--XB Series 8.1 Screw Connection Triple Level Sensor/Actuator XB3UKA25PE Terminal Width Maximum Wire Size 8 Connection Data in V/A/AWG UL-cUL Ratings in V/A/AWG Color Standard Pack Catalog Number 250/26/24-12 300/15/30-14 Gray 50 XB3UKA25PE 8 Gray 50 XB3UKA25PEL24 8 8 Screw Connection Triple Level 6.2 mm 14 AWG/2.5 mm2 Screw Connection Triple Level with Red LED, 15-30 Vdc, 2.5-7.5A 6.2 mm 14 AWG/2.5 mm2 250/26/24-12 300/15/30-14 8 8 Screw Connection Triple Level Sensor/Actuator XB3UKF25PE Terminal Width Maximum Wire Size Connection Data in V/A/AWG UL-cUL Ratings in V/A/AWG Color Standard Pack Catalog Number -- 300/15/30-14 Gray 50 XB3UKF25PE 8 Screw Connection Triple Level 6.2 mm 14 AWG/2.5 mm2 8 8 8 8 Accessories 8 Screw Connection Triple Level Sensor/Actuator Description Color Insertion bridge Insertion bridge Blank marker strip (strip of 10) Number of Positions Standard Pack XB3UKA25 Catalog Number XB3UKF25 Catalog Number XB3UKA25PE Catalog Number XB3UKF25PE Catalog Number Blue 80 1 XBAEB80DIKB XBAEB80DIKB XBAEB80DIKB XBAEB80DIKB Red 80 1 XBAEB80DIKR XBAEB80DIKR XBAEB80DIKR XBAEB80DIKR Blue 10 10 XBAEB10DIKB XBAEB10DIKB XBAEB10DIKB XBAEB10DIKB Red 10 10 XBAEB10DIKR XBAEB10DIKR XBAEB10DIKR XBAEB10DIKR White -- 10 XBMZB6 1 XBMZB6 2 XBMZB6 2 XBMZB6 2 8 8 8 8 8 Notes 1 For information on Printed Marking Tag Options, see Page V7-T8-98. 8 For additional accessories, see Page V7-T8-90. 8 8 8 8 8 8 8 8 8 8 8 8 Volume 7--Logic Control, Operator Interface and Connectivity Solutions CA08100008E--November 2011 www.eaton.com V7-T8-19 8.1 Terminal Blocks, Fuse Blocks and Fuse Holders IEC--XB Series 8 Technical Data and Specifications 8 Screw Connection Triple Level Sensor/Actuator 8 Technical Data in Accordance with IEC Description XB3UKA25 XB3UKF25 XB3UKA25PE XB3UKF25PE 8 Maximum load current in A/cross-section in mm2 26/2.5 30/4 26/2.5 26/2.5 Maximum cross section with insertion bridge solid/stranded in mm2 4/2.5 4/2.5 4/2.5 4/2.5 8 Rated surge voltage in kV/contamination class 4/3 4/3 4/3 6/3 Surge voltage category/insulating material group III/I III/I III/I III/I 0.25-2.5/0.25-2.5 0.25-2.5/0.25-2.5 0.25-2.5/0.25-2.5 0.25-2.5/0.25-2.5 8 8 8 8 8 8 8 8 Connection Capacity Stranded with ferrule/with ferrule and plastic sleeve in mm2 Multi-Conductor Connection (same cross-section) Solid/stranded in mm2 0.2-1.0/0.2-1.0 0.2-1.0/0.2-1.0 0.2-1.0/0.2-1.0 0.2-1.0/0.2-1.0 Stranded with ferrules without plastic sleeve in mm2 0.25-1.0 0.25-1.0 0.25-1.0 0.25-1.0 Stranded with twin ferrule with plastic sleeve in mm2 0.5-1.0 0.5-1.0 0.5-1.0 0.5-1.0 Stripping length in inches (mm) 0.31 (8) 0.31 (8) 0.31 (8) 0.31 (8) Thread M3 M3 M3 M3 Torque in in-lb (Nm) 4.4-5.3 (0.5-0.6) 4.4-5.3 (0.5-0.6) 4.4-5.3 (0.5-0.6) 4.4-5.3 (0.5-0.6) Wiring for Three-Level Sensor Terminal Blocks Wiring for Four-Level Sensor Terminal Blocks 8 8 8 8 8 8 8 Dimensions Approximate Dimensions in Inches (mm) 8 Screw Connection Triple Level Sensor/Actuator 8 Catalog Number Width Length 35 x 7.5 in 35 x 15 in 8 XB3UKA25 0.24 (6.2) 2.17 (55.0) 2.15 (54.5) 2.44 (62.0) XB3UKF25 0.24 (6.2) 2.85 (72.5) 2.15 (54.5) 2.44 (62.0) 8 XB3UKA25PE 0.24 (6.2) 2.46 (62.5) 2.76 (70.0) 3.05 (77.5) XB3UKF25PE 0.24 (6.2) 3.25 (82.5) 2.76 (70.0) 3.05 (77.5) 8 Height for-- 8 8 8 8 8 V7-T8-20 Volume 7--Logic Control, Operator Interface and Connectivity Solutions CA08100008E--November 2011 www.eaton.com 8.1 Terminal Blocks, Fuse Blocks and Fuse Holders IEC--XB Series Contents Fuse Terminal Blocks Description Page Single Level--Through-Feed . . . . . . . . . . . . . . . . . Single Level--Ground Blocks . . . . . . . . . . . . . . . . Multi-Conductor Terminal Blocks . . . . . . . . . . . . . . Multi-Conductor Ground Blocks . . . . . . . . . . . . . . Double Level. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Triple Level Sensor/Actuator . . . . . . . . . . . . . . . . . Fuse Terminal Blocks Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . Technical Data and Specifications . . . . . . . . . . Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . Disconnect and Component Terminal Blocks . . . . High Current Blocks . . . . . . . . . . . . . . . . . . . . . . . . Mini Screw Connection . . . . . . . . . . . . . . . . . . . . . 8 V7-T8-5 V7-T8-10 V7-T8-12 V7-T8-14 V7-T8-16 V7-T8-18 8 V7-T8-23 V7-T8-23 V7-T8-23 V7-T8-24 V7-T8-27 V7-T8-29 8 8 8 8 8 8 8 8 8 Fuse Terminal Blocks 8 Product Description The UT Series fuse terminal blocks come in two varieties-- lever type and cap. Each performs two functions. They act as a fuse carrier for most common North American and European fuses and they allow for potential distribution with the double bridge shaft. The terminal blocks therefore allow bypass routing of two separate potentials next to each other. This has the advantage of a time-saving potential infeed and a correct, functional configuration of the terminal strip. For signaling a triggered fuse, fuse terminal blocks with light indicators are available (for both AC and DC voltage). 8 8 8 8 Product Selection XBUT4FBE 8 Screw Connection Fuse Terminal Blocks, for 5 x 20 mm Fuse Terminal Width Maximum Wire Size 8 IEC 60 947-7-3 in V/A/AWG UL-cUL Ratings in V/A/AWG Color Standard Pack Catalog Number 1/6.3/26-10 600/6.3/26-10 Black 50 XBUT4FBE 600/6.3/26-10 Black 50 XBUT4FBEL24 8 600/6.3/26-10 Black 50 XBUT4FBEL60 8 600/6.3/26-10 Black 50 XBUT4FBEL250 8 8 Fuse Terminal Blocks 6.2 mm 10 AWG/4 mm2 8 Fuse Terminal Blocks with LED 12-30V, 1-2.5 mA 6.2 mm 10 AWG/4 mm2 1/6.3/26-10 Fuse Terminal Blocks with LED 30-60V, 0.8-2.0 mA 6.2 mm 10 AWG/4 mm2 1/6.3/26-10 Fuse Terminal Blocks with LED 110-250V, 0.5-2.5 mA 6.2 mm 10 AWG/4 mm2 1/6.3/26-10 8 Note 1 As disconnect terminal block 400V, as fuse terminal block 250V. 8 8 8 8 8 8 Volume 7--Logic Control, Operator Interface and Connectivity Solutions CA08100008E--November 2011 www.eaton.com V7-T8-21 8.1 8 XBUT6FBN Terminal Blocks, Fuse Blocks and Fuse Holders IEC--XB Series Screw Connection Fuse Terminal Blocks for 6.3 x 32 mm (1/4 in x 1-1/4 in) Fuse Terminal Width 8 Maximum Wire Size IEC 60 947-7-3 in V/A/AWG UL-cUL Ratings in V/A/AWG Color Standard Pack Catalog Number 1/10/24-8 400/10/24-8 Black 50 XBUT6FBN 400/10/24-8 Black 50 XBUT6FBNL24 400/10/24-8 Black 50 XBUT6FBNL60 400/10/24-8 Black 50 XBUT6FBNL250 Fuse Terminal Blocks 8 8.2 mm 8 AWG/6 mm2 Fuse Terminal Blocks with LED 12-30V, 1-2.5 mA 8 8.2 mm 8 AWG/6 mm2 1/10/24-8 Fuse Terminal Blocks with LED 30-60V, 0.8-2.0 mA 8 8.2 mm 8 AWG/6 mm2 1/10/24-8 Fuse Terminal Blocks with LED 110-250V, 0.5-2.5 mA 8 8.2 mm 8 AWG/6 mm2 1/10/24-8 8 8 XBUK10FBCE Screw Connection Fuse Terminal Blocks, XBUK10FBC IEC 60 947-7-3 with Fuse in V/A/AWG UL-cUL Ratings in V/A/AWG Color Standard Pack Catalog Number 800/10/20-6 300/20/22-6 Black 50 XBUK10FBCE 300/20/22-6 Black 50 XBUK10FBCN Black 50 XBUK10FBCEL24 Black 50 XBUK10FBCNL24 Black 50 XBUK10FBCEL250 Black 50 XBUK10FBCNL250 Terminal Width 8 Fuse Terminal Blocks for 5 x 20 mm fuse 8 Fuse Terminal Blocks for 6.3 x 32 mm (1/4 in x 1-1/4 in) fuse 12 mm 12 mm 8 Maximum Wire Size IEC 60 947-7-3 as Disconnected t.b. in V/A/AWG 8 6 AWG/16 mm2 6 AWG/16 mm2 1/1/20-4 1/1/20-4 800/10/20-6 Fuse Terminal Blocks with Light Indicator 15-30V, 1-2.5 mA, 5 x 20 mm 12 mm 8 6 AWG/16 mm2 1/1/20-4 800/10/20-6 300/20/22-6 Fuse Terminal Blocks with Light Indicator 15-30V, 1-2.5 mA, 6.3 x 32 mm 8 12 mm 8 12 mm 6 AWG/16 mm2 1/1/20-4 800/10/20-6 300/20/22-6 Fuse Terminal Blocks with Light Indicator 110-250V, 0.5-1.1A, 5 x 20 mm 6 AWG/16 mm2 1/1/20-4 800/10/20-6 300/20/22-6 Fuse Terminal Blocks with Light Indicator 110-250V, 0.5-1.1A, 6.3 x 32 mm 8 12 mm 6 AWG/16 mm2 1/1/20-4 800/10/20-6 300/20/22-6 8 Cartridge Fuse Inserts 5 x 20 mm Based on DIN EN 60 947-7-3: 2003-7 8 8 8 Terminal Blocks Overload Protection Short-Circuit Protection Only U (V) Individual Interconnected Individual Interconnected Imax. (A) XBUT4FBE 250 1.6W 1.6W 4W 2.5W 6.3 Notes Max. power dissipation at 73.4F (23C) based on DIN EN 60 947-7-3: 2003-7. When selecting cartridge fuse inserts, please ensure that the maximum power dissipation specified above is not exceeded. Details can be obtained from the fuse suppliers. If the fuse is defective, the downstream circuit is not off load. 8 8 1 As disconnect terminal block 500V, as fuse terminal block 400V. 8 8 8 8 8 8 8 8 V7-T8-22 Volume 7--Logic Control, Operator Interface and Connectivity Solutions CA08100008E--November 2011 www.eaton.com 8.1 Terminal Blocks, Fuse Blocks and Fuse Holders IEC--XB Series Accessories 8 Screw Connection Fuse Terminal Blocks XBUT4FBE Catalog Number XBUT6FBN Catalog Number XBUK10FBCE Catalog Number Description Color Number of Positions Standard Pack End cover -- -- -- 1 1 -- Plug-in bridge--for cross connections in the bridge shaft Red 2 10 XBAFBS26 XBAFBS28 -- 3 10 XBAFBS36 XBAFBS38 -- 5 10 XBAFBS56 XBAFBS58 -- 10 10 XBAFBS106 XBAFBS108 -- 50 10 XBAFBS506 -- -- 8 8 8 8 8 8 Blank marker strip center labeling (strip of 10) White -- -- XBMZB5 2 XBMZB6 2 -- Blank marker strip external labeling (strip of 10) White -- -- XBMZB6 2 XBMZB8 2 -- Fixed bridge -- 2 10 -- -- XBAFBI212 Screw heads with insulating collar -- 10 10 -- -- XBAFBI1012 Blank marker strip (strip of 10) White -- 10 -- -- XBMZB6 2 8 8 8 Technical Data and Specifications 8 Screw Connection Fuse Terminal Blocks Description XBUT4FBE XBUT4FBN XBUK10FBCE -- -- G/5 x 20/5 x 25/6.3 x 32 8 8 Technical Data in Accordance with IEC Fuse type/dimensions in (mm) Maximum cross section with insertion bridge solid/stranded in mm2 6.3/6 10/10 10/10 Rated surge voltage in kV/contamination class 4/3 4/3 4/3 Surge voltage category/insulating material group III/II III/II III/I 0.25-4/0.25-4 0.25-6/0.25-6 0.5-10/0.5-10 Solid/stranded in mm2 0.14-1.5/0.14-1.5 -- 0.5-4/0.5-4 Stranded with ferrules without plastic sleeve in mm2 0.25-1.5 -- 0.5-4 Stranded with twin ferrule with plastic sleeve in mm2 0.5-2.5 0.5-4 0.5-10 Stripping length in inches (mm) 0.35 (9) 0.39 (10) 0.43 (11) Thread M3 M4 M4 Torque in in-lb (Nm) 5.3-7.1 (0.6-0.8) 13.3-15.9 (1.5-1.8) 13.3-15.9 (1.5-1.8) 8 8 Connection Capacity Stranded with ferrule/with ferrule and plastic sleeve in mm2 8 8 Multi-Conductor Connection (same cross-section) 8 8 8 8 8 Dimensions Approximate Dimensions in Inches (mm) 8 Screw Connection Fuse Terminal Blocks 8 Height for-- Catalog Number Width Length 35 x 7.5 in 35 x 15 in 32 in XBUT4FBE 0.24 (6.2) 2.24 (56.8) 2.87 (73.0) 3.17 (80.5) -- XBUT4FBN 0.32 (8.2) 2.24 (56.8) 2.87 (73.0) 3.17 (80.5) -- XBUK10FBCE 0.47 (12.0) 2.44 (62.0) 2.32 (59.0) 2.62 (66.5) 2.52 (64.0) 8 8 8 Notes 1 XBUT4FBE and XBUT6FBN have an enclosed design. The use of an end cover is not required. 2 For information on Printed Marking Tag Options, see Page V7-T8-98. 8 For additional accessories, see Page V7-T8-90. 8 8 Volume 7--Logic Control, Operator Interface and Connectivity Solutions CA08100008E--November 2011 www.eaton.com V7-T8-23 8.1 8 Terminal Blocks, Fuse Blocks and Fuse Holders IEC--XB Series Contents Disconnect and Component Terminal Blocks Description 8 Single Level--Through-Feed . . . . . . . . . . . . . . . . . Single Level--Ground Blocks . . . . . . . . . . . . . . . . Multi-Conductor Terminal Blocks . . . . . . . . . . . . . Multi-Conductor Ground Blocks . . . . . . . . . . . . . . Double Level . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Triple Level Sensor/Actuator . . . . . . . . . . . . . . . . . Fuse Terminal Blocks . . . . . . . . . . . . . . . . . . . . . . . Disconnect and Component Terminal Blocks Product Selection . . . . . . . . . . . . . . . . . . . . . . . Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . Technical Data and Specifications . . . . . . . . . . Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . High Current Blocks . . . . . . . . . . . . . . . . . . . . . . . Mini Screw Connection . . . . . . . . . . . . . . . . . . . . . 8 8 8 8 8 8 8 8 8 Disconnect and Component Terminal Blocks 8 Product Description 8 8 8 8 8 8 The XB Series includes application specific terminal blocks like the XBUT4TG disconnect block that accommodates disconnect component and fuse terminal blocks. It can also be bridged with standard terminal blocks via the double bridge shaft. The component plug XBPCO serves to accommodate different components such as resistors or capacitors. 5 x 20 mm fuses can be inserted into the fuse plug XBPFU, also available with light indication. The XBUT4MT knife disconnect terminal block features a compact design and a high current carrying capacity of 16A. Versions with test socket screws provide a test option for 2.3 mm diameter test plugs on both sides of the disconnect point. 8 8 8 8 8 8 8 8 8 8 8 8 V7-T8-24 Volume 7--Logic Control, Operator Interface and Connectivity Solutions CA08100008E--November 2011 www.eaton.com Page V7-T8-5 V7-T8-10 V7-T8-12 V7-T8-14 V7-T8-16 V7-T8-18 V7-T8-21 V7-T8-25 V7-T8-26 V7-T8-26 V7-T8-26 V7-T8-27 V7-T8-29 Terminal Blocks, Fuse Blocks and Fuse Holders IEC--XB Series 8.1 Product Selection 8 Screw Connection Disconnect and Component Terminal Blocks XBUT4TG Disconnect Terminal Width 8 Connection Data in V/A/AWG UL-cUL Ratings for Disconnect in V/A/AWG UL-cUL Ratings for Disconnect with Test Sockets in V/A/AWG 500/16/26-10 600/16/26-10 300/16/26-10 Gray 50 XBUT4TG 500/16/26-10 600/16/26-10 300/16/26-10 Gray 50 XBUT4TGP 8 10 AWG/4 mm2 500/16/26-10 600/16/26-10 300/16/26-10 Gray 10 XBPCO 8 10 AWG/4 mm2 500/16/26-10 600/16/26-10 300/16/26-10 Black 10 XBPFU 8 300/16/26-10 Black 10 XBPFUL24 8 600/16/26-10 300/16/26-10 Black 10 XBPFUL250 600/16/26-10 300/16/26-10 Gray 50 XBUT4MT 300/16/26-10 Gray 50 XBUT4MTP 8 -- Gray 50 XBUKK4DIO 8 Maximum Wire Size Color Standard Pack Catalog Number 8 8 Screw Connection Disconnect 6.2 mm 10 AWG/4 mm2 8 Screw Connection Disconnect with Test Sockets 6.2 mm 10 AWG/4 mm2 Component Plug 6.2 mm Fuse Plug 6.2 mm Fuse Plug with Light Indicator for 12-30V, 1-2.5 mA 6.2 mm 10 AWG/4 mm2 500/16/26-10 600/16/26-10 Fuse Plug with Light Indicator for 110-250V, 0.5-2.5 mA 6.2 mm 10 AWG/4 mm2 500/16/26-10 8 Screw Connection Disconnect Knife Disconnect 6.2 mm 10 AWG/4 mm2 500/16/26-10 8 Screw Connection Disconnect Knife Disconnect with Test Sockets 6.2 mm 10 AWG/4 mm2 500/16/26-10 600/16/26-10 Screw Connection Terminal Blocks with Integrated Diodes 6.2 mm XBTKT25 Thermal Electric Voltage 12 AWG/4 mm2 500/32/24-10 600/30/26-10 8 Screw Connection Thermoelectric Voltage Terminal Blocks Terminal Width Maximum Wire Size 8 Connection Data in V/A/AWG UL-cUL Ratings in V/A/AWG Color Standard Pack Catalog Number 400/--/24-12 300/10/28-12 Gray 50 XBTKT25 (Type T) 400/--/24-12 300/10/28-12 Gray 50 XBTKJ25 (Type J) 8 400/--/24-12 300/10/28-12 Gray 50 XBTKE25 (Type E) 8 400/--/24-12 300/10/28-12 Gray 50 XBTKK25 (Type K) 8 400/--/24-12 300/10/28-12 Gray 50 XBTKR25 (Type R) 8 8 Copper/Constantan (CU/CUNI44) 10.4 mm 12 AWG/2.5 mm2 Iron/Constantan (FE/CUNI44) 10.4 mm 12 AWG/2.5 mm2 Nickel-Chrome/Constantan (NICR/CUNI44) 10.4 mm 12 AWG/2.5 mm2 Nickel-Chrome/Nickel (NICRNI) 10.4 mm 12 AWG/2.5 mm2 Copper/Copper Nickel (E-CU/A-CU) 10.4 mm 12 AWG/2.5 mm2 8 8 8 8 8 8 8 8 8 8 Volume 7--Logic Control, Operator Interface and Connectivity Solutions CA08100008E--November 2011 www.eaton.com V7-T8-25 8.1 Terminal Blocks, Fuse Blocks and Fuse Holders IEC--XB Series 8 Accessories 8 Screw Connection Disconnect and Component Terminal Blocks 8 Description Color 8 Plug-in bridge--for cross connections in the bridge shaft Red Number of Positions Standard Pack XBUT4TG Catalog Number XBUT4MT Catalog Number XBUKK4DI0 Catalog Number XBTKT25 Catalog Number 2 10 XBAFBS26 XBAFBS26 -- -- 3 10 XBAFBS36 XBAFBS36 -- -- 8 5 10 XBAFBS56 XBAFBS56 -- -- 10 10 XBAFBS106 XBAFBS106 -- -- 8 50 10 XBAFBS506 XBAFBS506 -- -- Test adapter -- -- 10 XBATSPAI4 XBATSPAI4 -- -- 2.3 mm diameter test plug -- -- -- XBATSMPS-_ 1 XBATSMPS-_ 1 -- -- Modular test plug -- -- 10 XBATSDPPS6 XBATSDPPS6 -- -- Blank marker strip (strip of 10) White -- 10 XBMZB6 2 XBMZB6 2 XBMZB6 2 XBMZB10 2 End cover Gray -- 10 -- -- XBACUKK35 XBACTK4 Spacer cover Gray -- 10 -- -- XBADGUKK35 -- 8 Spacer plate -- -- 10 -- -- XBADPUKK35 -- Partition plate -- -- -- -- -- -- XBATTK4 8 Fixed bridge -- 10 10 -- -- XBAFBI106 -- 8 8 8 8 Technical Data and Specifications 8 Screw Connection Disconnect and Component Terminal Blocks 8 Technical Data in Accordance with IEC 8 8 8 8 8 8 Description XBUT4TG XBUT4MT XBUKK4DI0 XBTK Maximum load current in A/cross-section in mm2 16/6 16/6 32/4 -- Rated surge voltage in kV/contamination class 6/3 6/3 6/3 -- Surge voltage category/insulating material group III/I III/I III/I -- 0.25-4/0.25-4 0.25-4/0.25-4 0.25-4/0.25-2.5 -- Connection Capacity Stranded with ferrule/with ferrule and plastic sleeve in mm2 Multi-Conductor Connection (same cross-section) Solid/stranded in mm2 0.14-1.5/0.14-1.5 0.14-1.5/0.14-1.5 0.2-1.5/0.2-1.5 -- Stranded with ferrules without plastic sleeve in mm2 0.25-1.5 0.25-1.5 0.25-1.5 -- Stranded with twin ferrule with plastic sleeve in mm2 -- 0.5-2.5 0.5-2.5 0.5-1.5 8 Stripping length in inches (mm) 0.35 (9) 0.35 (9) 0.31 (8) 0.28 (7) Thread M3 M3 M3 M3 8 Torque in in-lb (Nm) 5.3-7.1 (0.6-0.8) 5.3-7.1 (0.6-0.8) 5.3-7.1 (0.6-0.8) 5.3-7.1 (0.6-0.8) 8 8 8 8 8 8 8 8 Dimensions Approximate Dimensions in Inches (mm) Screw Connection Disconnect and Component Terminal Blocks Catalog Number Length Cover Width Height for-- Width 35 x 7.5 in 35 x 15 in 32 in XBUT4TG 0.24 (6.2) 2.24 (56.8) -- 1.87 (47.5) 2.17 (55.0) -- XBUT4MT 0.24 (6.2) 2.24 (56.8) -- 1.87 (47.5) 2.17 (55.0) -- XBUKK4DI0 0.24 (6.2) 2.20 (56.0) 0.10 (2.5) 2.44 (62.0) 2.74 (69.5) 2.64 (67.0) XBTK 0.20 (5.2) 1.81 (46.0) 0.04 (1.0) 1.57 (40.0) 1.87 (47.5) 1.77 (45.0) Notes 1 For ordering information, see Page V7-T8-105. 2 For information on Printed Marking Tag Options, see Page V7-T8-98. For additional accessories, see Page V7-T8-90. V7-T8-26 Volume 7--Logic Control, Operator Interface and Connectivity Solutions CA08100008E--November 2011 www.eaton.com 8.1 Terminal Blocks, Fuse Blocks and Fuse Holders IEC--XB Series Contents High Current Blocks Description Page Single Level--Through-Feed . . . . . . . . . . . . . . . . . Single Level--Ground Blocks . . . . . . . . . . . . . . . . Multi-Conductor Terminal Blocks . . . . . . . . . . . . . . Multi-Conductor Ground Blocks . . . . . . . . . . . . . . Double Level. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Triple Level Sensor/Actuator . . . . . . . . . . . . . . . . . Fuse Terminal Blocks . . . . . . . . . . . . . . . . . . . . . . . Disconnect and Component Terminal Blocks . . . . High Current Blocks Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . Technical Data and Specifications . . . . . . . . . . Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . Mini Screw Connection . . . . . . . . . . . . . . . . . . . . . 8 V7-T8-5 V7-T8-10 V7-T8-12 V7-T8-14 V7-T8-16 V7-T8-18 V7-T8-21 V7-T8-24 8 V7-T8-28 V7-T8-28 V7-T8-28 V7-T8-29 8 8 8 8 8 8 8 8 8 High Current Blocks 8 Product Description Eaton's XBUK high current terminal blocks offer a reliable connection via the superior construction that includes three-point centering of the wire in the prism-shaped sleeve base, a fluted contact surface for low contact resistance, and screws secured with spring-loaded elements. The terminal blocks have an enclosed housing made from polyamide 6.6. Greenyellow ground terminal blocks are also available. 8 8 8 8 Product Selection XBUK150 8 Screw Connection High Current Blocks 1 Terminal Width Maximum Wire Size IEC 60 947-7-1 in V/A/AWG EN 50 019 in V/A/AWG UL-cUL Ratings in V/A/AWG Color Standard Pack Catalog Number 20.0 mm 1/0/50 mm2 1000/150/1/0 750/135/1/0 600/150/1/0 Gray 10 XBUK50 Blue 10 XBUK50BU Gray 10 XBUK150 31.0 mm 300 kcmil/150 mm2 1000/309/2-300 726/265/2-300 600/285/ 2 AWG-300 kcmil 8 8 8 8 8 XBUK95PE Screw Connection High Current Ground Blocks Terminal Width Maximum Wire Size IEC 60 947-7-1 in V/A/AWG EN 50 019 1 in V/A/AWG UL-cUL Ratings in V/A/AWG Color 25.0 mm 000 AWG/95 mm2 --/232/4-000 --/--/4-000 --/--/2-4/0 Green/Yellow 10 Standard Pack 8 Catalog Number 8 XBUK95PE 8 8 8 Note 1 U type--examination certificate number: KEMA 05ATEX2170 U (XBUK50), KEMA 05ATEX2171 U (XBUK150). 8 8 8 Volume 7--Logic Control, Operator Interface and Connectivity Solutions CA08100008E--November 2011 www.eaton.com V7-T8-27 8.1 Terminal Blocks, Fuse Blocks and Fuse Holders IEC--XB Series 8 Accessories 8 Screw Connection High Current Blocks XBUK150 Catalog Number XBUK95PE Catalog Number Description Color 8 Fixed bridge, screw heads with insulating color -- 2 10 XBAFBI220 -- -- Insertion bridge -- 2 10 -- XBAEB231 -- 8 Blank marker strip external labeling (strip of 10) White -- 10 XBMZB10 1 XBMZB10 1 XBMZB10 1 8 8 Technical Data and Specifications 8 Screw Connection High Current Blocks 8 8 8 8 8 8 8 8 8 8 8 Description XBUK50 Standard Pack XBUK50 Catalog Number Number of Positions XBUK150 XBUK95PE Technical Data in Accordance with IEC Maximum load current in A/cross-section in mm2 150/50 309/150 232/95 Maximum cross-section with insertion bridge solid/stranded in mm2 --/-- 150/120 --/-- Rated surge voltage in kV/contamination class 8/3 8/3 8/3 Surge voltage category/insulating material group III/I III/I III/I 25-50/25-50 50-150/50-150 35-95/35-95 Connection Capacity Stranded with ferrule/with ferrule and plastic sleeve in mm2 Multi-Conductor Connection (same cross-section) Solid/stranded in mm2 10-16/10-16 25-50/35-50 25-35/25-35 Stranded with ferrules without plastic sleeve in mm2 10-16 25-50 16-35 Stripping length in inches (mm) 0.94 (24) 1.57 (40) 1.18 (30) M8 Thread M6 M10 Terminal point--thread/torque in in-lb (Nm) 53-71 (6-8) 221-267 (25-30) 133-177 (15-20) Fastening--thread/torque in in-lb (Nm) 53-71 (6-8) 221-267 (25-30) 133-177 (15-20) Dimensions 8 Approximate Dimensions in Inches (mm) 8 Screw Connection High Current Blocks 8 Catalog Number Width Length 8 XBUK50 0.79 (20.0) 2.78 (70.5) 3.29 (83.5) 3.21 (81.5) -- XBUK150 1.22 (31.0) 3.94 (100.0) 4.67 (118.5) 4.57 (116.0) -- 8 XBUK95PE 0.98 (25.0) 3.27 (83.0) -- 3.90 (99.0) 3.80 (96.5) 8 8 Height for-- 35 x 7.5 in 35 x 15 in 32 in Notes 1 For information on Printed Marking Tag Options, see Page V7-T8-98. For additional accessories, see Page V7-T8-90. 8 8 8 8 8 V7-T8-28 Volume 7--Logic Control, Operator Interface and Connectivity Solutions CA08100008E--November 2011 www.eaton.com 8.1 Terminal Blocks, Fuse Blocks and Fuse Holders IEC--XB Series Contents Mini Screw Connection Terminal Blocks Description Page Single Level--Through-Feed. . . . . . . . . . . . . . . . . . Single Level--Ground Blocks . . . . . . . . . . . . . . . . Multi-Conductor Terminal Blocks . . . . . . . . . . . . . . Multi-Conductor Ground Blocks . . . . . . . . . . . . . . Double Level. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Triple Level Sensor/Actuator . . . . . . . . . . . . . . . . . Fuse Terminal Blocks . . . . . . . . . . . . . . . . . . . . . . . Disconnect and Component Terminal Blocks . . . . High Current Blocks . . . . . . . . . . . . . . . . . . . . . . . . Mini Screw Connection Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . Technical Data and Specifications . . . . . . . . . . Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . V7-T8-5 V7-T8-10 V7-T8-12 V7-T8-14 V7-T8-16 V7-T8-18 V7-T8-21 V7-T8-24 V7-T8-27 V7-T8-30 V7-T8-30 V7-T8-30 8 8 8 8 8 8 8 8 8 8 8 Mini Screw Connection 8 Product Description The XB miniature terminal blocks have a connection cross-section from 2 mm2 through 4 mm2 and mount on 15 mm DIN rail. There is an opening for bridging with a fixed bridge in the center of the terminal blocks. These miniature terminal blocks also offer the same accessories that you would find with the larger blocks--including marking tags, end covers, end stop and ground blocks. 8 8 8 Product Selection XBMUK4 8 Mini Screw Connection Terminal Blocks Terminal Width Maximum Wire Size IEC 60 947-7-1 in V/A/AWG EN 50 019 1 in V/A/AWG UL-cUL Ratings in V/A/AWG 5.2 mm 12 AWG/2.5 mm2 400/32/24-12 275/28/21/24-12 600/20/28-12 6.2 mm 10 AWG/4 mm2 500/41/24-10 --/--/-- 600/10/26-10 8 Color Standard Pack Catalog Number Gray 50 XBMUK25 Blue 50 XBMUK25BU Gray 50 XBMUK4 Blue 50 XBMUK4BU 8 8 8 8 8 XBMUK25PE Mini Screw Connection Ground Blocks Terminal Width Maximum Wire Size IEC 60 947-7-2 in V/A/AWG UL-cUL Ratings in V/A/AWG 5.2 mm 12 AWG/2.5 mm2 --/--/24-12 --/--/30-12 6.2 mm 10 AWG/2.4 mm2 --/--/24-10 --/--/26-14 8 Standard Pack Catalog Number Green/ Yellow 50 XBMUK25PE 8 Green/ Yellow 50 XBMUK4PE 8 Color 8 8 Note 1 EU type--examination certificate number: KEMA 05ATEX2169 U (XBMUK25). 8 8 8 Volume 7--Logic Control, Operator Interface and Connectivity Solutions CA08100008E--November 2011 www.eaton.com V7-T8-29 8.1 Terminal Blocks, Fuse Blocks and Fuse Holders IEC--XB Series 8 Accessories 8 Mini Screw Connection Terminal/Ground Blocks 8 Description Color Number of Positions Standard Pack XBMUK25 Catalog Number XBMUK4 Catalog Number XBMUK25PE Catalog Number XBMUK4PE Catalog Number -- 8 End cover Gray -- 10 XBACMU254 XBACMU254 -- Blue -- 10 XBACMU254B XBACMU254B -- 8 Partition plate -- -- -- 10 XBATMU254 XBATMU254 -- -- Fixed bridge -- 8 Separating plate -- 10 10 XBAFBR105N -- -- -- -- 10 XBATMPKK15 XBATMPKK15 -- -- Blank marker strip (strip of 10) White -- 10 XBMZB5 1 XBMZB6 1 XBMZB5 1 XBMZB6 1 8 8 Technical Data and Specifications 8 Mini Spring Cage Terminal/Ground Blocks 8 Technical Data in Accordance with IEC Description XBMUK25 XBMUK4 XBMUK25PE XBMUK4PE 41/6 -- -- 8 Maximum load current in A/cross-section in mm2 32/4 Maximum cross-section with insertion bridge (solid/stranded) 2.5/2.5 4/4 -- -- 8 Rated surge voltage in kV/contamination class 6/3 6/3 6/3 6/3 Surge voltage category/insulating material group III/I III/I III/I III/I Stranded with ferrule with plastic sleeve in mm2 0.25-1.5 0.25-2.5 0.25-1.5 0.25-2.5 Stranded with ferrule without plastic sleeve in mm2 0.25-2.5 0.25-4 0.25-2.5 0.25-4 Solid/stranded in mm2 0.2-1.0/0.2-1.5 0.2-1.5/0.2-1.5 0.2-1.0/0.2-1.5 0.2-1.5/0.2-1.5 Stranded with ferrule without plastic sleeve in mm2 0.25-1.5 0.25-1.5 0.25-1.5 0.25-1.5 Stranded with ferrule with plastic sleeve in mm2 0.5-1.0 0.5-2.5 0.5-1.5 0.5-2.5 Stripping length in Inches (mm) 0.31 (8) 0.31 (8) 0.31 (8) 0.31 (8) Thread M3 M3 M3 M3 Torque in in-lb (Nm) 5.3-7.1 (0.6-0.8) 4.4-5.3 (0.5-0.6) 5.3-7.1 (0.6-0.8) 5.3-7.1 (0.6-0.8) 8 8 8 8 8 8 Connection Cross-Section Multi-Conductor Connection (same cross-section) 8 8 8 8 8 8 8 8 Dimensions Approximate Dimensions in Inches (mm) Mini Spring Cage Terminal/Ground Blocks Catalog Number Length Cover Length Height for-- Width XBMUK25 0.20 (5.2) 1.10 (28.0) 0.04 (1.0) 1.26 (32.0) XBMUK4 0.24 (6.2) 1.10 (28.0) 0.04 (1.0) 1.26 (32.0) XBMUK25PE 0.20 (5.2) 1.10 (28.0) -- 1.24 (31.5) XBMUK4PE 0.24 (6.2) 1.10 (28.0) -- 1.26 (32.0) 15 in Notes 1 For information on Printed Marking Tag Options, see Page V7-T8-98. For additional accessories, see Page V7-T8-90. 8 8 8 8 V7-T8-30 Volume 7--Logic Control, Operator Interface and Connectivity Solutions CA08100008E--November 2011 www.eaton.com Terminal Blocks, Fuse Blocks and Fuse Holders IEC--XB Series 8.1 Contents Spring Cage Connection Description Page Spring Cage Terminal Blocks Single Level--Through-Feed . . . . . . . . . . . . . . . Single Level--Ground Blocks . . . . . . . . . . . . . . Multi-Conductor Terminal Blocks . . . . . . . . . . . Multi-Conductor Ground Blocks . . . . . . . . . . . . Double Level Blocks . . . . . . . . . . . . . . . . . . . . . Triple Level Blocks . . . . . . . . . . . . . . . . . . . . . . Fuse Terminal Blocks . . . . . . . . . . . . . . . . . . . . Disconnect and Component Terminal Blocks . . Hybrid Terminal Blocks . . . . . . . . . . . . . . . . . . . Mini Spring Cage . . . . . . . . . . . . . . . . . . . . . . . . 8 8 V7-T8-32 V7-T8-37 V7-T8-39 V7-T8-42 V7-T8-44 V7-T8-46 V7-T8-48 V7-T8-51 V7-T8-54 V7-T8-56 8 8 8 8 8 8 Drawings Online 8 8 8 Spring Cage Terminal Blocks Overview Product Description Application Description Features The XBPT Series incorporates a spring cage connection system proven in applications that are sensitive to vibration. The spring mechanism always exerts the same constant force on the wire, resulting in a vibrationproof, gas-tight connection, independent of the user. The space-saving front connection, with the wire and screwdriver coming in parallel from the same direction, allows for simple wiring in places where there is little space available. The connection point is opened with a standard screwdriver. After the wire has been inserted into the wire guide of the terminal block, the screwdriver is removed and the wire automatically makes contact. Vibration-resistance Global acceptance Multi-conductor connections Flexible Plug-in bridge system Large surface area for marking Standardized testing system Standards and Certifications UL recognized--File No. E67464 CE approved LVD 1: EN 60947-7-1 EN 60947-7-2 EN 60998-2-3 EN 60352-4/A1 ATEX approval (Eex e applications) 8 8 8 8 8 8 8 8 Note 1 Not all standards apply to all terminal blocks. Contact Eaton for details. 8 8 8 8 8 8 8 8 8 8 8 Volume 7--Logic Control, Operator Interface and Connectivity Solutions CA08100008E--November 2011 www.eaton.com V7-T8-31 8.1 8 Terminal Blocks, Fuse Blocks and Fuse Holders IEC--XB Series Contents Single Level--Through-Feed Description 8 Single Level--Through-Feed Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . Technical Data and Specifications . . . . . . . . . . Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . Single Level--Ground Blocks . . . . . . . . . . . . . . . . Multi-Conductor Terminal Blocks . . . . . . . . . . . . . Multi-Conductor Ground Blocks . . . . . . . . . . . . . . Double Level Blocks . . . . . . . . . . . . . . . . . . . . . . . Triple Level Blocks . . . . . . . . . . . . . . . . . . . . . . . . . Fuse Terminal Blocks . . . . . . . . . . . . . . . . . . . . . . . Disconnect and Component Terminal Blocks . . . . Hybrid Terminal Blocks . . . . . . . . . . . . . . . . . . . . . Mini Spring Cage . . . . . . . . . . . . . . . . . . . . . . . . . . 8 8 8 8 8 8 8 8 8 Single Level--Through-Feed 8 Product Description 8 8 8 8 8 The space-saving design and front entry design make the XBPT Series ideal for control systems where there is little space. Even so, they offer maximum connection space, resulting in fast wiring of stranded and solid conductors with or without ferrules. XBPT terminal blocks are available with cross-sections from 2.5 mm2 up to 35 mm2. The double bridge shaft can accommodate individual chain bridging and stepdown bridging from other terminal blocks. 8 8 8 8 8 8 8 8 8 8 8 8 8 V7-T8-32 Volume 7--Logic Control, Operator Interface and Connectivity Solutions CA08100008E--November 2011 www.eaton.com Page V7-T8-34 V7-T8-36 V7-T8-36 V7-T8-37 V7-T8-39 V7-T8-42 V7-T8-44 V7-T8-46 V7-T8-48 V7-T8-51 V7-T8-54 V7-T8-56 8.1 Terminal Blocks, Fuse Blocks and Fuse Holders IEC--XB Series Product Selection XBPT6 8 Spring Cage Connection Single Level--Through-Feed Terminal Width Maximum Wire Size IEC 60 947-7-1 in V/A/AWG EN 50 019 1 in V/A/AWG UL-cUL Ratings in V/A/AWG 5.2 mm 12 AWG/2.5 mm2 800/31/28-12 550/25/21/24-12 600/20/26-12 6.2 mm 10 AWG/4 mm2 800/40/28-10 550/34/30/24-10 600/30/20-10 8.2 mm 8 AWG/6 mm2 800/52/24-8 550/45/36/20-8 600/50/20-8 10.2 mm 6 AWG/10 mm2 800/65/24-6 550/50/63/16-6 600/65/16-6 12 mm 4 AWG/16 mm2 800/90/24-4 550/65/82/16-4 600/50/16-4 16 mm 2 AWG/35 mm2 800/125/14-2 750/108/14-2 600/115/14-2 8 Color Standard Pack Catalog Number Gray 50 XBPT25 Blue 50 XBPT25BU White 50 XBPT25WH Red 50 XBPT25RD Black 50 XBPT25BK Gray 50 XBPT4 Blue 50 XBPT4BU Gray 50 XBPT6 Blue 50 XBPT6BU Gray 50 XBPT10 Blue 50 XBPT10BU Gray 50 XBPT16 Blue 50 XBPT16BU Gray 50 XBPT35 Blue 50 XBPT35BU 8 8 8 8 8 8 8 8 8 8 Note 1 EU type--examination certificate number: KEMA 05ATEX2158 U. 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 Volume 7--Logic Control, Operator Interface and Connectivity Solutions CA08100008E--November 2011 www.eaton.com V7-T8-33 8.1 Terminal Blocks, Fuse Blocks and Fuse Holders IEC--XB Series 8 Accessories 8 Spring Cage Connection Single Level--Through-Feed, XBPT25, XBPT4 an d XBPT6 Standard Pack XBPT25 Catalog Number XBPT4 Catalog Number XBPT6 Catalog Number Description Color Number of Positions 8 End cover Gray -- 10 XBACPT25 XBACPT4 XBACPT6 Partition plate Gray -- 10 XBATPT4 XBATPT4 XBATPT6 8 Plug-in bridge--for cross connections in the bridge shaft Red 2 10 XBAFBS25 XBAFBS26 XBAFBS28 3 10 XBAFBS35 XBAFBS36 -- 8 5 10 XBAFBS55 XBAFBS56 -- 10 10 XBAFBS105 XBAFBS106 -- 8 50 10 XBAFBS505 XBAFBS506 -- 8 8 8 8 8 Test adapter -- -- 10 XBATSPAI4 XBATSPAI4 XBATSPAI4 2.3 mm diameter test plug -- -- -- XBATSMPS-_ 1 XBATSMPS-_ 1 XBATSMPS-_ 1 Modular test plug -- -- 10 XBATSPS5 XBATSPS6 XBATSPS8 Blank marker strip external labeling White -- 10 XBMZBF5 2 XBMZBF6 2 XBMZF8 2 Blank marker strip center labeling (strip of 10) White -- 10 XBMZB5 2 XBMZB6 2 XBMZB8 2 XBPT16 Catalog Number XBPT35 Catalog Number Spring Cage Connection Single Level--Through-Feed, XBPT10, XBPT16 and XBPT35 8 8 8 8 8 8 8 Description Color Number of Positions Standard Pack XBPT10 Catalog Number End cover Gray -- 10 XBACPT10 XBACPT16 3 Plug-in bridge--for cross connections in the bridge shaft Red 2 10 XBAFBS210 XBAFBS212 1 XBAFBS216 2 2.3 mm diameter test plug -- -- 10 XBATSMPS-_ 1 XBATSMPS-_ 1 XBATSMPS-_ 1 Blank marker strip external labeling White -- 10 XBMZF10 2 XBMZBF12 2 XBMZBF15 2 Blank marker strip center labeling (strip of 10) White -- 10 XBMZB10 2 XBMZB12 2 XBMZB15 2 Notes 1 For ordering information, see Page V7-T8-105. 2 For information on Printed Marking Tag Options, see Page V7-T8-98. 3 XBPT35 has an enclosed design. The use of an end cover is not required. For additional accessories, see Page V7-T8-90. 8 8 8 8 8 8 8 8 8 8 8 8 V7-T8-34 Volume 7--Logic Control, Operator Interface and Connectivity Solutions CA08100008E--November 2011 www.eaton.com Terminal Blocks, Fuse Blocks and Fuse Holders IEC--XB Series 8.1 XBPT with Reducing Bridge 8 XBPT6 8 XBACPT6 lmax 8 lmax 8 8 8 XBARBST6 8 8 Central Input One-Sided Input XBPT25 XBPT25 8 XBACPT25 8 Step-Down Bridge with Standard Feed-Through Terminal Blocks Input Pick-Off Terminal Blocks Cross-Section Terminal Blocks Cross-Section AWG (mm2) XBPT6 8 AWG (6 mm2) XBPT25 12 (2.5) XBPT4 10 (4) XBQT15 14 (1.5) XBQT25 12 (2.5) XBPT10 XBPT16 6 AWG (10 mm2) 4 AWG (16 mm2) Central Input Imax Bridge 8 Catalog Number 8 40 56 XBARBST6 45 56 XBARBST6 8 35 56 XBARBST6 40 56 XBARBST6 One-Sided Input Imax XBPT25 12 (2.5) 40 65 XBARBST10 XBPT4 10 (4) 45 65 XBARBST10 XBQT15 14 (1.5) 35 65 XBARBST10 XBQT25 12 (2.5) 40 65 XBARBST10 XBPT25 12 (2.5) 40 80 XBARBST16 XBPT4 10 (4) 45 90 XBARBST16 XBQT15 14 (1.5) 35 70 XBARBST16 XBQT25 12 (2.5) 40 80 XBARBST16 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 Volume 7--Logic Control, Operator Interface and Connectivity Solutions CA08100008E--November 2011 www.eaton.com V7-T8-35 8.1 Terminal Blocks, Fuse Blocks and Fuse Holders IEC--XB Series 8 Technical Data and Specifications 8 Spring Cage Connection Single Level--Through-Feed 8 Technical Data in Accordance with IEC 8 Maximum load current in A/cross-section in mm2 31/4 40/6 52/10 65/16 90/25 125/35 Rated surge voltage in kV/contamination class 8/3 8/3 8/3 8/3 8/3 8/3 Surge voltage category/insulating material group III/I III/I III/I III/I III/I III/I 0.25-4 0.25-6 0.25-10 0.25-16 2.5-35 8 Description XBPT25 XBPT4 XBPT6 XBPT10 XBPT16 XBPT35 Connection Capacity 8 Stranded with ferrule/with ferrule and plastic sleeve in mm2 0.25-2.5 8 Stranded with ferrules without plastic sleeve in mm2 0.25-2.5 0.25-4 0.25-6 0.25-10 0.25-16 2.5-35 Stranded with twin ferrule with plastic sleeve in mm2 0.5 0.5-1 0.5-1.5 1.5-2.5 1.5-4 2.5-10 0.39 (10) 0.39 (10) 0.47 (12) 0.71 (18) 0.71 (18) 0.98 (25) 8 8 Stripping length in inches (mm) Dimensions 8 Approximate Dimensions in Inches (mm) 8 Spring Cage Connection Single Level--Through-Feed 8 Catalog Number Length Cover Width Height for-- Width 35 x 7.5 in 35 x 15 in 8 XBPT25 0.20 (5.2) 1.91 (48.5) 0.09 (2.2) 1.45 (36.8) 1.73 (44.0) XBPT4 0.24 (6.2) 2.20 (56.0) 0.09 (2.2) 1.45 (36.8) 1.73 (44.0) 8 XBPT6 0.32 (8.2) 2.74 (69.5) 0.09 (2.2) 1.71 (43.5) 2.01 (51.0) XBPT10 0.39 (10.0) 2.81 (71.5) 0.09 (2.2) 1.99 (50.5) 2.30 (58.5) 8 XBPT16 0.47 (12.0) 3.15 (80.0) 0.09 (2.2) 2.01 (51.0) 2.30 (58.5) 3.94 (100.0) 1 2.32 (59.0) 2.62 (66.5) 8 8 XBPT35 0.63 (16.0) Note 1 XBPT35 has an enclosed design. The use of an end cover is not required. 8 8 8 8 8 8 8 8 8 8 8 8 8 V7-T8-36 Volume 7--Logic Control, Operator Interface and Connectivity Solutions CA08100008E--November 2011 www.eaton.com Terminal Blocks, Fuse Blocks and Fuse Holders IEC--XB Series 8.1 Contents Single Level--Ground Blocks Description Page Single Level--Through-Feed . . . . . . . . . . . . . . . . . Single Level--Ground Blocks Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . Technical Data and Specifications . . . . . . . . . . Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . Multi-Conductor Terminal Blocks . . . . . . . . . . . . . . Multi-Conductor Ground Blocks . . . . . . . . . . . . . . Double Level Blocks . . . . . . . . . . . . . . . . . . . . . . . Triple Level Blocks . . . . . . . . . . . . . . . . . . . . . . . . . Fuse Terminal Blocks . . . . . . . . . . . . . . . . . . . . . . . Disconnect and Component Terminal Blocks . . . . Hybrid Terminal Blocks . . . . . . . . . . . . . . . . . . . . . Mini Spring Cage . . . . . . . . . . . . . . . . . . . . . . . . . . V7-T8-32 V7-T8-38 V7-T8-38 V7-T8-38 V7-T8-39 V7-T8-42 V7-T8-44 V7-T8-46 V7-T8-48 V7-T8-51 V7-T8-54 V7-T8-56 8 8 8 8 8 8 8 8 8 8 Single Level--Ground Blocks 8 Product Description 8 The XBPT ground blocks are the same shape as the feedthrough terminal blocks with the same wide range of cross-sections available. They easily snap onto the DIN rail to make a reliable mechanical and electrical contact that meets all requirements of IEC 60-947-7-2. 8 8 8 8 Product Selection XBPT4PE 8 Spring Cage Connection Single Level--Ground Blocks Terminal Width Maximum Wire Size IEC 60 947-7-2 in V/A/AWG EN 50 019 1 in V/A/AWG UL-cUL Ratings in V/A/AWG Color Standard Pack Catalog Number 8 5.2 mm 12 AWG/2.5 mm2 --/--/28-12 --/--/24-12 --/--/26-12 Green/Yellow 50 XBPT25PE 6.2 mm 10 AWG/4 mm2 --/--/28-10 --/--/24-10 --/--/20-10 Green/Yellow 50 XBPT4PE 8 8.2 mm 8 AWG/6 mm2 --/--/24-8 --/--/20-8 --/--/20-8 Green/Yellow 50 XBPT6PE 10.2 mm 6 AWG/10 mm2 --/65/24-6 --/--/16-6 --/--/16-6 Green/Yellow 50 XBPT10PE 12 mm 4 AWG/16 mm2 --/90/24-4 --/--/16-4 2 --/--/16-4 Green/Yellow 25 XBPT16PE 16 mm 2 AWG/35 mm2 --/125/14-2 --/--/14-2 2 --/--/14-2 Green/Yellow 10 XBPT35PE Notes 1 EU type--examination certificate number: KEMA 05ATEX2154 U (XBPT25PE), KEMA 05ATEX2155 U (XBPT4PE). 2 EU type--examination certificate number: KEMA 05ATEX2156 U. 8 8 8 8 8 8 8 8 8 8 8 Volume 7--Logic Control, Operator Interface and Connectivity Solutions CA08100008E--November 2011 www.eaton.com V7-T8-37 8.1 Terminal Blocks, Fuse Blocks and Fuse Holders IEC--XB Series 8 Accessories 8 Spring Cage Connection Single Level Ground Blocks, XBPT25PE, XBPT4PE and XBPT6PE Standard Pack XBPT25PE Catalog Number XBPT4PE Catalog Number XBPT6PE Catalog Number Color Number of Positions 8 End cover Gray -- 10 XBACPT25 XBACPT4 XBACPT6 Blank marker strip external labeling White -- 10 XBMZBF5 1 XBMZBF6 1 XBMZBF8 1 8 Blank marker strip center labeling (strip of 10) White -- 10 XBMZB5 1 XBMZB6 1 XBMZB8 1 8 8 Description Spring Cage Connection Single Level Ground Blocks, XBPT10PE, XBPT16PE and XBPT35PE 8 Standard Pack XBPT10PE Catalog Number XBPT16PE Catalog Number XBPT35PE Catalog Number 8 Description Color Number of Positions End cover Gray -- 10 XBACPT10 XBACPT16 2 8 Plug-in bridge--for cross connections in the bridge shaft -- 2 10 XBAFBS210 XBAFBS212 XBAFBS216 8 Blank marker strip external labeling White -- 10 XBMZBF10 1 XBMZBF12 1 XBMZBF15 1 Blank marker strip center labeling (strip of 10) White -- 10 XBMZB10 1 XBMZB12 1 XBMZB15 1 8 8 Technical Data and Specifications 8 Spring Cage Connection Single Level Ground Blocks Description XBPT25PE XBPT4PE XBPT6PE XBPT10PE XBPT16PE XBPT35PE Maximum load current in A/cross-section in mm2 -- -- -- 65/16 90/25 125/35 Rated surge voltage in kV/contamination class 8/3 8/3 8/3 8/3 8/3 8/3 III/I III/I III/I III/I III/I III/I Stranded with ferrule with plastic sleeve in mm2 0.25-2.5 0.25-4 0.25-6 0.25-10 0.25-16 2.5-35 Stranded with ferrules without plastic sleeve in mm2 0.25-2.5 0.25-4 0.25-6 0.25-10 0.25-16 2.5-35 Stranded with twin ferrule with plastic sleeve in mm2 0.5 0.5-1 0.5-1.5 1.5-2.5 1.5-4 2.5-10 0.39 (10) 0.39 (10) 0.47 (12) 0.71 (18) 0.71 (18) 0.98 (25) 8 Technical Data in Accordance with IEC 8 Surge voltage category/insulating material group 8 8 8 8 8 8 8 8 8 8 8 8 8 Connection Capacity Stripping length in inches (mm) Dimensions Approximate Dimensions in Inches (mm) Spring Cage Connection Single Level Ground Blocks Catalog Number Length Cover Width Height for-- Width 35 x 7.5 in 35 x 15 in XBPT25PE 0.20 (5.2) 1.91 (48.5) 0.09 (2.2) 1.45 (36.8) 1.73 (44.0) XBPT4PE 0.24 (6.2) 2.20 (56.0) 0.09 (2.2) 1.45 (36.8) 1.73 (44.0) XBPT6PE 0.32 (8.2) 2.74 (69.5) 0.09 (2.2) 1.71 (43.5) 2.01 (51.0) XBPT10PE 0.39 (10.0) 2.81 (71.5) 0.09 (2.2) 1.99 (50.5) 2.28 (58.0) XBPT16PE 0.47 (12.0) 3.15 (80.0) 0.09 (2.2) 2.01 (51.0) 2.30 (58.5) XBPT35PE 0.63 (16.0) 3.94 (100.0) -- 2.32 (59.0) 2.62 (66.5) Notes 1 For information on Printed Marking Tag Options, see Page V7-T8-98. 2 XBPT35PE has an enclosed design. The use of an end cover is not required. For additional accessories, see Page V7-T8-90. 8 8 V7-T8-38 Volume 7--Logic Control, Operator Interface and Connectivity Solutions CA08100008E--November 2011 www.eaton.com 8.1 Terminal Blocks, Fuse Blocks and Fuse Holders IEC--XB Series Contents Multi-Conductor Terminal Blocks Description Page Single Level--Through-Feed . . . . . . . . . . . . . . . . . Single Level--Ground Blocks . . . . . . . . . . . . . . . . . Multi-Conductor Terminal Blocks Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . Technical Data and Specifications . . . . . . . . . . Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . Multi-Conductor Ground Blocks . . . . . . . . . . . . . . Double Level Blocks . . . . . . . . . . . . . . . . . . . . . . . Triple Level Blocks . . . . . . . . . . . . . . . . . . . . . . . . . Fuse Terminal Blocks . . . . . . . . . . . . . . . . . . . . . . . Disconnect and Component Terminal Blocks . . . . Hybrid Terminal Blocks . . . . . . . . . . . . . . . . . . . . . Mini Spring Cage . . . . . . . . . . . . . . . . . . . . . . . . . . V7-T8-32 V7-T8-37 V7-T8-40 V7-T8-41 V7-T8-41 V7-T8-42 V7-T8-44 V7-T8-46 V7-T8-48 V7-T8-51 V7-T8-54 V7-T8-56 8 8 8 8 8 8 8 8 8 8 8 Multi-Conductor Terminal Blocks 8 Product Description The multi-conductor terminal blocks offer a space-saving alternative to standard feedthrough terminal blocks, allowing for high-density wiring. Often, three connections have to be led to one terminal block. The XBPT...D12 terminal block accomplishes this without any additional terminal blocks or bridging required. The XBPT...D22 terminal blocks allow four wires to be connected to one potential-- and can therefore be used as compact power distributors. There is also a version, XBPT25D22U or XBPT4D22U, with an interrupted bus bar in the terminal center. This makes two feed-through terminal blocks available in one level. One side of this block can be bridged using the standard Plug-in bridges. Double marker carriers are available for clear marking of the feed-through levels. 8 8 8 8 8 Product Selection XBPT4D12 8 Spring Cage Connection Multi-Conductor Terminal Blocks, Three-Wire Terminal Width Maximum Wire Size IEC 60 947-7-1 in V/A/AWG EN 50 019 1 in V/A/AWG UL-cUL Ratings in V/A/AWG 5.2 mm 12 AWG/2.5 mm2 800/28/28-12 550/25/21/24-12 600/20/26-12 6.2 mm 10 AWG/4 mm2 800/40/28-10 550/34/29/24-10 600/30/20-10 8 Color Standard Pack Catalog Number Gray 50 XBPT25D12 Blue 50 XBPT25D12BU Gray 50 XBPT4D12 Blue 50 XBPT4D12BU 8 8 8 8 Note 1 EU type--examination certificate number: KEMA 05ATEX2154 U (XBPT25D12), KEMA 05ATEX2155 U (XBPT4D12). 8 8 8 8 8 8 8 Volume 7--Logic Control, Operator Interface and Connectivity Solutions CA08100008E--November 2011 www.eaton.com V7-T8-39 8.1 8 Terminal Blocks, Fuse Blocks and Fuse Holders IEC--XB Series Spring Cage Connection Multi-Conductor Terminal Blocks, Four-Wire XBPT25D22 Terminal Width 8 Maximum Wire Size IEC 60 947-7-1 in V/A/AWG EN 50 019 1 in V/A/AWG UL-cUL Ratings in V/A/AWG 800/28/28-12 550/24/21/24-12 600/20/26-12 Color Standard Pack Catalog Number Spring Cage Multi-Conductor 8 5.2 mm 8 6.2 mm 8 12 AWG/2.5 mm2 10 AWG/4 mm2 800/40/28-10 550/34/25/24-10 600/30/20-10 Gray 50 XBPT25D22 Blue 50 XBPT25D22BU Gray 50 XBPT4D22 Blue 50 XBPT4D22BU Spring Cage Multi-Conductor with Interrupted Bus Bar 8 5.2 mm 12 AWG/2.5 mm2 800/28/28-12 550/24/21/24-12 600/20/26-12 Blue 50 XBPT25D22U 6.2 mm 10 AWG/4 mm2 800/40/28-10 550/34/25/24-10 600/30/20-10 Blue 50 XBPT4D22U 8 8 8 Accessories Spring Cage Connection Multi-Conductor Terminal Blocks 8 Standard Pack XBPT25D12 Catalog Number XBPT4D12 Catalog Number XBPT25D22 Catalog Number XBPT4D22 Catalog Number 8 Description Color Number of Positions End cover Gray -- 10 XBACPT25D12 XBACPT4D12 XBACPT25D22 XBACPT4D22 8 End cover segment Gray -- 10 XBASPT25 XBASPT4 XBASPT25 XBASPT4 Partition plate -- -- 10 XBATPTD12 XBATPTD12 XBATPTD22 XBATPTD22 8 Plug-in bridge--for cross connections in the bridge shaft Red 2 10 XBAFBS25 XBAFBS26 XBAFBS25 XBAFBS26 3 10 XBAFBS35 XBAFBS36 XBAFBS35 XBAFBS36 5 10 XBAFBS55 XBAFBS56 XBAFBS55 XBAFBS56 10 10 XBAFBS105 XBAFBS106 XBAFBS105 XBAFBS106 50 10 XBAFBS505 XBAFBS506 XBAFBS505 XBAFBS506 8 8 8 Test adapter -- -- 10 XBATSPAI4 XBATSPAI4 XBATSPAI4 XBATSPAI4 2.3 mm diameter test plug -- -- -- XBATSMPS-_ 2 XBATSMPS-_ 2 XBATSMPS-_ 2 XBATSMPS-_ 2 8 Modular test plug -- -- 10 XBATSPS5 XBATSPS6 XBATSPS5 XBATSPS6 Blank marker strip external labeling White -- 10 XBMZBF5 3 XBMZBF6 3 XBMZBF5 3 XBMZBF6 3 8 Blank marker strip center labeling (strip of 10) White -- 10 XBMZB5 3 XBMZB6 3 XBMZB5 3 XBMZB6 3 8 8 Notes 1 EU type--examination certificate number: KEMA 05ATEX2154 U (XBPT25D22), KEMA 05ATEX2155 (XBPT4D22). 2 For ordering information, see Page V7-T8-105. 3 For information on Printed Marking Tag Options, see Page V7-T8-98. For additional accessories, see Page V7-T8-90. 8 8 8 8 8 8 8 8 8 8 V7-T8-40 Volume 7--Logic Control, Operator Interface and Connectivity Solutions CA08100008E--November 2011 www.eaton.com 8.1 Terminal Blocks, Fuse Blocks and Fuse Holders IEC--XB Series Technical Data and Specifications 8 Spring Cage Connection Multi-Conductor Terminal Blocks Description XBPT25D12 XBPT4D12 XBPT25D22 XBPT4D22 28/4 40/6 28/4 40/6 8 8 Technical Data in Accordance with IEC Maximum load current in A/cross-section in mm2 Rated surge voltage in kV/contamination class 8/3 8/3 8/3 8/3 Surge voltage category/insulating material group III/I III/I III/I III/I Stranded with ferrule with plastic sleeve in mm2 0.25-2.5 0.25-4 0.25-2.5 0.25-4 Stranded with ferrules without plastic sleeve in mm2 0.25-2.5 0.25-4 0.25-2.5 0.25-4 Stranded with twin ferrule with plastic sleeve in mm2 0.5 0.5-1 0.5 0.5-1 0.39 (10) 0.39 (10) 0.39 (10) 0.39 (10) 8 8 Connection Capacity Stripping length in inches (mm) 8 8 8 8 Dimensions Approximate Dimensions in Inches (mm) 8 Spring Cage Connection Multi-Conductor Terminal Blocks 8 Catalog Number Length Cover Width Height for-- Width 35 x 7.5 in 35 x 15 in XBPT25D12 0.20 (5.2) 2.38 (60.5) 0.09 (2.2) 1.44 (36.5) 1.73 (44.0) XBPT4D12 0.24 (6.2) 2.81 (71.5) 0.09 (2.2) 1.44 (36.5) 1.73 (44.0) XBPT25D22 0.20 (5.2) 2.83 (72.0) 0.09 (2.2) 1.44 (36.5) 1.73 (44.0) XBPT4D22 0.24 (6.2) 3.43 (87.0) 0.09 (2.2) 1.44 (36.5) 1.73 (44.0) 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 Volume 7--Logic Control, Operator Interface and Connectivity Solutions CA08100008E--November 2011 www.eaton.com V7-T8-41 8.1 8 Terminal Blocks, Fuse Blocks and Fuse Holders IEC--XB Series Contents Multi-Conductor Terminal Blocks Description 8 Page Single Level--Through-Feed . . . . . . . . . . . . . . . . . Single Level--Ground Blocks . . . . . . . . . . . . . . . . . Multi-Conductor Terminal Blocks . . . . . . . . . . . . . Multi-Conductor Ground Blocks Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . Technical Data and Specifications . . . . . . . . . . Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . Double Level Blocks . . . . . . . . . . . . . . . . . . . . . . . Triple Level Blocks . . . . . . . . . . . . . . . . . . . . . . . . . Fuse Terminal Blocks . . . . . . . . . . . . . . . . . . . . . . . Disconnect and Component Terminal Blocks . . . . Hybrid Terminal Blocks . . . . . . . . . . . . . . . . . . . . . Mini Spring Cage . . . . . . . . . . . . . . . . . . . . . . . . . . 8 8 8 8 8 8 V7-T8-32 V7-T8-37 V7-T8-39 V7-T8-43 V7-T8-43 V7-T8-43 V7-T8-44 V7-T8-46 V7-T8-48 V7-T8-51 V7-T8-54 V7-T8-56 8 8 8 Multi-Conductor Ground Blocks 8 Product Description 8 8 The ground terminal blocks have the same shape and pitch as the standard terminal block, in a green-yellow housing. They easily snap onto the DIN rail to make a reliable mechanical and electrical contact that meets all requirements of IEC 60-947-7-2. 8 8 8 Product Selection XBPT25D12PE 8 8 Spring Cage Connection Multi-Conductor Ground Blocks, Three-Wire Terminal Width Maximum Wire Size IEC 60 947-7-2 in V/A/AWG EN 50 019 1 in V/A/AWG UL-cUL Ratings in V/A/AWG Color Standard Pack Catalog Number 5.2 mm 12 AWG/2.5 mm2 --/--/28-12 --/--/24-12 --/--/26-12 Green/Yellow 50 XBPT25D12PE 6.2 mm 10 AWG/4 mm2 --/--/28-10 --/--/24-10 --/--/20-10 Green/Yellow 50 XBPT4D12PE 8 8 8 XBPT4D22PE Spring Cage Connection Multi-Conductor Ground Blocks, Four-Wire Maximum Wire Size IEC 60 947-7-2 in V/A/AWG EN 50 019 1 in V/A/AWG UL-cUL Ratings in V/A/AWG Color Standard Pack Catalog Number 5.2 mm 12 AWG/2.5 mm2 --/--/28-12 --/--/24-12 --/--/26-12 Green/Yellow 50 XBPT25D22PE 6.2 mm 10 AWG/4 mm2 --/--/28-10 --/--/24-10 --/--/20-10 Green/Yellow 50 XBPT4D22PE Terminal Width 8 8 8 8 Note 1 EU type--examination certificate number: KEMA 05ATEX2154 U (XBPT25D12PE), KEMA 05ATEX2155 U (XBPT4D12PE). 8 8 8 8 V7-T8-42 Volume 7--Logic Control, Operator Interface and Connectivity Solutions CA08100008E--November 2011 www.eaton.com 8.1 Terminal Blocks, Fuse Blocks and Fuse Holders IEC--XB Series Accessories 8 Spring Cage Connection Multi-Conductor Ground Blocks Description Color Number of Positions Standard Pack XBPT25D12PE Catalog Number XBPT4D12PE Catalog Number XBPT25D22PE Catalog Number XBPT4D22PE Catalog Number End cover Gray -- 10 XBACPT25D12 XBACPT4D12 XBACPT25D22 XBACPT4D22 End cover segment Gray -- 10 XBASPT25 XBASPT4 XBASPT25 XBASPT4 Blank marker strip external labeling White -- 10 XBMZBF5 1 XBMZBF6 1 XBMZBF5 1 XBMZBF6 1 Blank marker strip center labeling (strip of 10) White -- 10 XBMZB5 1 XBMZB6 1 XBMZB5 1 XBMZB6 1 8 8 8 8 8 Technical Data and Specifications 8 Spring Cage Connection Multi-Conductor Ground Blocks 8 Description XBPT25D12PE XBPT4D12PE XBPT25D22PE XBPT4D22PE Maximum load current in A/cross-section in mm2 -- -- -- -- Rated surge voltage in kV/contamination class 8/3 8/3 8/3 8/3 Surge voltage category/insulating material group III/I III/I III/I III/I Stranded with ferrule with plastic sleeve in mm2 0.25-2.5 0.25-4 0.25-2.5 0.25-4 Stranded with ferrules without plastic sleeve in mm2 0.25-2.5 0.25-4 0.25-2.5 0.25-4 Stranded with twin ferrule with plastic sleeve in mm2 0.5 0.5-1 0.5 0.5-1 0.39 (10) 0.39 (10) 0.39 (10) 0.39 (10) 8 Technical Data in Accordance with IEC 8 8 Connection Capacity Stripping length in inches (mm) 8 8 8 8 Dimensions Approximate Dimensions in Inches (mm) 8 Spring Cage Connection Multi-Conductor Ground Blocks 8 Catalog Number Length Cover Width Height for-- Width 35 x 7.5 in 35 x 15 in XBPT25D12PE 0.20 (5.2) 2.38 (60.5) 0.09 (2.2) 1.44 (36.5) 1.73 (44.0) XBPT4D12PE 0.24 (6.2) 2.81 (71.5) 0.09 (2.2) 1.44 (36.5) 1.73 (44.0) XBPT25D22PE 0.20 (5.2) 2.83 (72.0) 0.09 (2.2) 1.44 (36.5) 1.73 (44.0) XBPT4D22PE 0.24 (6.2) 3.43 (87.0) 0.09 (2.2) 1.44 (36.5) 1.73 (44.0) 8 8 8 8 Notes 1 For information on Printed Marking Tag Options, see Page V7-T8-98. 8 For additional accessories, see Page V7-T8-90. 8 8 8 8 8 8 8 8 Volume 7--Logic Control, Operator Interface and Connectivity Solutions CA08100008E--November 2011 www.eaton.com V7-T8-43 8.1 8 Terminal Blocks, Fuse Blocks and Fuse Holders IEC--XB Series Contents Double Level Blocks Description 8 Page Single Level--Through-Feed . . . . . . . . . . . . . . . . . Single Level--Ground Blocks . . . . . . . . . . . . . . . . . Multi-Conductor Terminal Blocks . . . . . . . . . . . . . Multi-Conductor Ground Blocks . . . . . . . . . . . . . . Double Level Blocks Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . Technical Data and Specifications . . . . . . . . . . Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . Triple Level Blocks . . . . . . . . . . . . . . . . . . . . . . . . . Fuse Terminal Blocks . . . . . . . . . . . . . . . . . . . . . . . Disconnect and Component Terminal Blocks . . . . Hybrid Terminal Blocks . . . . . . . . . . . . . . . . . . . . . Mini Spring Cage . . . . . . . . . . . . . . . . . . . . . . . . . . 8 8 8 8 8 8 V7-T8-32 V7-T8-37 V7-T8-39 V7-T8-42 V7-T8-45 V7-T8-45 V7-T8-45 V7-T8-46 V7-T8-48 V7-T8-51 V7-T8-54 V7-T8-56 8 8 8 Double Level Blocks 8 Product Description 8 8 8 The potentials of the XB double level terminal blocks routed on two levels reduce space requirements by 50% compared with single level terminal blocks. 8 Product Selection 8 XBPTT4 customization for each application. The XBPTT25PV and XBPTT4PV terminal blocks have two interconnected levels. Maximum Wire Size IEC 60 947-7-1 in V/A/AWG EN 50 019 1 in V/A/AWG UL-cUL Ratings in V/A/AWG 420/23/19/24-12 600/20/26-12 Color Standard Pack Catalog Number Spring Cage Connection Double Level Blocks 8 5.2 mm 8 6.2 mm 12 AWG/2.5 mm2 10 AWG/4 mm2 500/26/28-12 500/32/28-10 420/32/27/24-10 300/30/20-10 8 Gray 50 XBPTT25 Blue 50 XBPTT25BU Gray 50 XBPTT4 Blue 50 XBPTT4BU Spring Cage Connection Double Level Blocks (terminal block with potential distribution between the levels) 8 8 8 Equipotential bonding is marked by an imprint on the housing. These terminal blocks can also be bridged and used to construct compact potential distributor blocks. Spring Cage Connection Double Level Blocks Terminal Width 8 The XBPTT blocks can be bridged on both levels with the Plug-in bridge system and labeling options are available for each terminal point, resulting in maximum XBPTT25PE 5.2 mm 112 AWG/2.5 mm2 500/26/28-12 420/23/19/24-12 600/20/26-12 Gray 50 XBPTT25PV 6.2 mm 10 AWG/4 mm2 500/32/28-10 420/32/27/24-10 300/30/20-10 Gray 50 XBPTT4PV Spring Cage Connection Double Level Ground Blocks 8 Terminal Width Maximum Wire Size IEC 60 947-7-2 in V/A/AWG EN 50 019 1 in V/A/AWG UL-cUL Ratings in V/A/AWG Color Standard Pack Catalog Number 8 5.2 mm 12 AWG/2.5 mm2 --/--/28-12 --/--/24-12 --/--/26-12 Green/Yellow 50 XBPTT25PE 6.2 mm 10 AWG/4 mm2 --/--/28-10 --/--/24-10 --/--/20-10 Green/Yellow 50 XBPTT4PE 8 8 Note 1 EU type--examination certificate number: KEMA 05ATEX2154 U (XBPTT25), KEMA 05ATEX2155 U (XBPTT4). 8 8 V7-T8-44 Volume 7--Logic Control, Operator Interface and Connectivity Solutions CA08100008E--November 2011 www.eaton.com 8.1 Terminal Blocks, Fuse Blocks and Fuse Holders IEC--XB Series Accessories 8 Spring Cage Connection Double Level Blocks Description Color Number of Positions Standard Pack XBPTT25 Catalog Number XBPTT4 Catalog Number XBPTT25PE Catalog Number XBPTT4PE Catalog Number End cover Gray -- 10 XBACPTT25 XBACPTT4 XBACPTT25 XBACPTT4 Partition plate -- -- 10/50 XBATPTT4 XBATPTT4 -- -- Plug-in bridge--for cross connections in the bridge shaft Red 2 10 XBAFBS25 XBAFBS26 XBAFBS25 XBAFBS26 3 10 XBAFBS35 XBAFBS36 XBAFBS35 XBAFBS36 5 10 XBAFBS55 XBAFBS56 XBAFBS55 XBAFBS56 10 10 XBAFBS105 XBAFBS106 XBAFBS105 XBAFBS106 50 10 XBAFBS505 XBAFBS506 XBAFBS505 XBAFBS506 Test adapter -- -- 10 XBATSPAI4 XBATSPAI4 -- -- Modular test plug -- -- 10 XBATSPS5 XBATSPS6 -- -- Blank marker strip (strip of 10) White -- 10 XBMZBF5 1 XBMZBF6 1 XBMZBF5 1 XBMZBF6 1 8 8 8 8 8 8 8 8 Technical Data and Specifications 8 Spring Cage Connection Double Level Blocks 8 Description XBPTT25 XBPTT4 XBPTT25PE XBPTT4PE 8 8 Technical Data in Accordance with IEC Maximum load current in A/cross-section in mm2 26/4 32/6 -- -- Rated surge voltage in kV/contamination class 6/3 6/3 6/3 6/3 Surge voltage category/insulating material group III/I III/I III/I III/I 8 Stranded with ferrule with plastic sleeve in mm2 0.25-2.5 0.25-4 0.25-2.5 0.25-4 8 Stranded with ferrules without plastic sleeve in mm2 0.25-2.5 0.25-4 0.25-2.5 0.25-4 Stranded with twin ferrule with plastic sleeve in mm2 0.5 0.5-1 0.5 0.5-1 0.39 (10) 0.39 (10) 0.39 (10) 0.39 (10) Connection Capacity Stripping length in inches (mm) 8 8 8 Dimensions 8 Approximate Dimensions in Inches (mm) 8 Spring Cage Connection Double Level Blocks Catalog Number Width Length Cover Width Height for-- 35 x 7.5 in 8 35 x 15 in XBPTT25 0.20 (5.2) 2.66 (67.5) 0.09 (2.2) 1.87 (47.5) 2.17 (55.0) XBPTT4 0.24 (6.2) 3.29 (83.5) 0.09 (2.2) 1.87 (47.5) 2.17 (55.0) XBPTT25PE 0.20 (5.2) 2.66 (67.5) 0.09 (2.2) 1.87 (47.5) 2.17 (55.0) XBPTT4PE 0.24 (6.2) 3.29 (83.5) 0.09 (2.2) 1.87 (47.5) 2.17 (55.0) 8 8 8 Notes 1 For information on Printed Marking Tag Options, see Page V7-T8-98. 8 For additional accessories, see Page V7-T8-90. 8 8 8 8 8 Volume 7--Logic Control, Operator Interface and Connectivity Solutions CA08100008E--November 2011 www.eaton.com V7-T8-45 8.1 8 Terminal Blocks, Fuse Blocks and Fuse Holders IEC--XB Series Contents Triple Level Blocks Description 8 Page Single Level--Through-Feed . . . . . . . . . . . . . . . . . Single Level--Ground Blocks . . . . . . . . . . . . . . . . . Multi-Conductor Terminal Blocks . . . . . . . . . . . . . Multi-Conductor Ground Blocks . . . . . . . . . . . . . . Double Level Blocks . . . . . . . . . . . . . . . . . . . . . . . Triple Level Blocks Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . Technical Data and Specifications . . . . . . . . . . Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . Fuse Terminal Blocks . . . . . . . . . . . . . . . . . . . . . . . Disconnect and Component Terminal Blocks . . . . Hybrid Terminal Blocks . . . . . . . . . . . . . . . . . . . . . Mini Spring Cage . . . . . . . . . . . . . . . . . . . . . . . . . . 8 8 8 8 8 8 V7-T8-32 V7-T8-37 V7-T8-39 V7-T8-42 V7-T8-44 V7-T8-47 V7-T8-47 V7-T8-47 V7-T8-48 V7-T8-51 V7-T8-54 V7-T8-56 8 8 8 Triple Level Blocks 8 Product Description 8 8 8 The spring cage triple level terminal block incorporates three feed-through levels in a 5.2 mm wide housing. This is ideal for high density wiring, especially important 8 Product Selection 8 XBPTK25 8 8 8 when switchgear space is restricted. There is a bridge shaft on each level allowing use of this block as a compact potential distributor or as a sensor terminal. The XBPTK25PV has all six terminal points interconnected. All the triple level blocks can be labeled on each level. Spring Cage Connection Triple Level Blocks Terminal Width Maximum Wire Size IEC 60 947-7-1 in V/A/AWG UL-cUL Ratings in V/A/AWG Color Standard Pack Catalog Number 5.2 mm 12 AWG/2.5 mm2 500/28/28-12 600/20/26-12 Gray 50 XBPTK25 5.2 mm 12 AWG/2.5 mm2 500/28/28-12 600/20/26-12 Gray 50 XBPTK25PV 1 Note 1 Terminal block with potential distribution between the levels. 8 8 8 8 8 8 8 8 8 8 V7-T8-46 Volume 7--Logic Control, Operator Interface and Connectivity Solutions CA08100008E--November 2011 www.eaton.com 8.1 Terminal Blocks, Fuse Blocks and Fuse Holders IEC--XB Series Accessories 8 Spring Cage Connection Triple Level Blocks Description Color Number of Positions Standard Pack XBPTK25 Catalog Number XBPTK25PV Catalog Number End cover Gray -- 10 XBACPT25K XBACPT25K Plug-in bridge--for cross connections in the bridge shaft Red 2 10 XBAFBS25 XBAFBS25 3 10 XBAFBS35 XBAFBS35 5 10 XBAFBS55 XBAFBS55 10 10 XBAFBS105 XBAFBS105 50 10 XBAFBS505 XBAFBS505 Test adapter -- -- 10 XBATSPAI4 XBATSPAI4 Modular test plug -- -- 10 XBATSPS5 XBATSPS5 Blank marker strip (strip of 10) White -- 10 XBMZBF5 1 XBMZBF5 1 8 8 8 8 8 8 8 8 Technical Data and Specifications 8 Spring Cage Connection Triple Level Blocks Description XBPTK25 XBPTK25PV 28/4 28/4 8 Technical Data in Accordance with IEC Maximum load current in A/cross-section in mm2 Rated surge voltage in kV/contamination class 6/3 6/3 Surge voltage category/insulating material group III/I III/I Stranded with ferrule with plastic sleeve in mm2 0.25-2.5 0.25-2.5 Stranded with ferrules without plastic sleeve in mm2 0.25-2.5 0.25-2.5 Stranded with twin ferrule with plastic sleeve in mm2 0.5 0.5 0.39 (10) 0.39 (10) 8 8 8 Connection Capacity Stripping length in inches (mm) 8 8 8 8 Dimensions Approximate Dimensions in Inches (mm) 8 Spring Cage Connection Triple Level Blocks 8 Catalog Number Length Cover Length Height for-- Width 35 x 7.5 in 35 x 15 in XBPTK25 0.20 (5.2) 3.92 (99.5) 0.09 (2.2) 2.28 (58.0) 2.58 (65.5) XBPTK25PV 0.20 (5.2) 3.92 (99.5) 0.09 (2.2) 2.28 (58.0) 2.58 (65.5) 8 8 Notes 1 For information on Printed Marking Tag Options, see Page V7-T8-98. 8 For additional accessories, see Page V7-T8-90. 8 8 8 8 8 8 8 Volume 7--Logic Control, Operator Interface and Connectivity Solutions CA08100008E--November 2011 www.eaton.com V7-T8-47 8.1 8 Terminal Blocks, Fuse Blocks and Fuse Holders IEC--XB Series Contents Fuse Terminal Blocks Description 8 Page Single Level--Through-Feed . . . . . . . . . . . . . . . . . Single Level--Ground Blocks . . . . . . . . . . . . . . . . . Multi-Conductor Terminal Blocks . . . . . . . . . . . . . Multi-Conductor Ground Blocks . . . . . . . . . . . . . . Double Level Blocks . . . . . . . . . . . . . . . . . . . . . . . Triple Level Blocks . . . . . . . . . . . . . . . . . . . . . . . . . Fuse Terminal Blocks Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . Technical Data and Specifications . . . . . . . . . . Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . Disconnect and Component Terminal Blocks . . . . Hybrid Terminal Blocks . . . . . . . . . . . . . . . . . . . . . Mini Spring Cage . . . . . . . . . . . . . . . . . . . . . . . . . . 8 8 8 8 8 8 V7-T8-32 V7-T8-37 V7-T8-39 V7-T8-42 V7-T8-44 V7-T8-46 V7-T8-49 V7-T8-50 V7-T8-50 V7-T8-51 V7-T8-54 V7-T8-56 8 8 8 Fuse Terminal Blocks 8 Product Description 8 8 The spring cage fuse terminal blocks act as a fuse carrier for 5 x 20 mm or 6.3 x 32 mm fuses. They also allow for potential distribution with the double bridge shaft. For signaling a triggered fuse, fuse terminal blocks with light indicators are available (for both AC and DC voltage). 8 8 8 Product Selection XBPT4FBE Spring Cage Connection Fuse Terminal Blocks, for 5 x 20 mm Fuse 8 Terminal Width 8 Fuse Terminal Blocks 6.2 mm 8 Maximum Wire Size 10 AWG/4 mm2 IEC 60 947-7-3 with Fuse in V/A/AWG IEC 60 947-7-3 as Disconnect Terminal Blocks in V/A/AWG UL-cUL Ratings in V/A/AWG Color Standard Pack Catalog Number 1/1/28-10 250/6.3/28-10 300/6.3/24-10 Black 50 XBPT4FBE 250/6.3/28-10 300/6.3/24-10 Black 50 XBPT4FBEL24 250/6.3/28-10 300/6.3/24-10 Black 50 XBPT4FBEL60 250/6.3/28-10 300/6.3/24-10 Black 50 XBPT4FBEL250 Fuse Terminal Blocks with LED 15-30V, 3.5-8.1A 8 6.2 mm 8 6.2 mm 8 6.2 mm 10 AWG/4 mm2 1/1/28-10 Fuse Terminal Blocks with LED 30-60V, 0.8-2.0A 10 AWG/4 mm2 1/1/28-10 Fuse Terminal Blocks with LED 110-250V, 0.5-1.0A 10 AWG/4 mm2 1/1/28-10 Notes The cartridge fuse holders should be selected according to the maximum power dissipation (self-heating) of the cartridge fuse inserts. The thermal conditions in closed fuse holes should be checked according to the application and installation. Higher ambient temperatures are an additional strain on fuse inserts. In applications of this kind, the shift of the rated current should be taken into consideration accordingly. Maximum power dissipation at 73.4F (23C) (in accordance with IEC 60 947-7-3). When selecting cartridge fuse inserts, please ensure that the maximum power dissipation specified at right is not exceeded. Details can be obtained from the fuse suppliers. Cartridge Fuse Inserts 5 x 20 and 6.3 x 32 mm in accordance. with IEC 60 947-7-3. 8 8 8 8 1 8 The current is determined by the fuse used, the voltage by the selected light indicator. See Page V7-T8-49. 8 8 V7-T8-48 Volume 7--Logic Control, Operator Interface and Connectivity Solutions CA08100008E--November 2011 www.eaton.com 8.1 Terminal Blocks, Fuse Blocks and Fuse Holders IEC--XB Series Spring Cage Connection Fuse Terminal Blocks, for 6.3 x 32 mm (1/4 in x 1-1/4 in) Fuse XBPT4FBN Terminal Width Maximum Wire Size 8 IEC 60 947-7-3 with Fuse in V/A/AWG IEC 60 947-7-3 as Disconnect Terminal Blocks in V/A/AWG UL-cUL Ratings in V/A/AWG Color Standard Pack Catalog Number 400/10/28-10 400/10/28-10 300/10/24-10 Black 50 XBPT4FBN 400/10/28-10 300/10/24-10 Black 50 XBPT4FBNL24 8 300/10/24-10 Black 50 XBPT4FBNL250 8 8 8 Fuse Terminal Blocks 8.2 mm 10 AWG/4 mm2 Fuse Terminal Blocks with LED 12-30V, 1.0-2.5 mA 8.2 mm 10 AWG/4 mm2 400/10/28-10 Fuse Terminal Blocks with LED 110-250V, 0.5-2.5 mA 8.2 mm 10 AWG/4 mm2 400/10/28-10 400/10/28-10 8 8 Accessories 8 8 Spring Cage Connection Fuse Terminal Blocks Description Color Number of Positions Standard Pack XBPT4FBE Catalog Number XBPT4FBN Catalog Number Partition plate -- -- 10 XBATPT4 XBATQTD12 Plug-in bridge--for cross connections in the bridge shaft Red 2 10 XBAFBS26 XBAFBS28 3 10 XBAFBS36 -- 5 10 XBAFBS56 -- 10 10 XBAFBS106 -- Blank marker strip external labeling White -- 10 XBMZBF6 1 XBMZBF8 1 Blank marker strip center labeling (strip of 10) White -- 10 XBMZB5 1 XBMZB6 1 8 8 8 8 8 8 Notes The cartridge fuse holders should be selected according to the maximum power dissipation (self-heating) of the cartridge fuse inserts. The thermal conditions in closed fuse holes should be checked according to the application and installation. Higher ambient temperatures are an additional strain on fuse inserts. In applications of this kind, the shift of the rated current should be taken into consideration accordingly. Maximum power dissipation at 73.4F (23C) (in accordance with IEC 60 947-7-3). When selecting cartridge fuse inserts, please ensure that the maximum power dissipation specified at right is not exceeded. Details can be obtained from the fuse suppliers. Cartridge Fuse Inserts 5 x 20 and 6.3 x 32 mm in accordance. with IEC 60 947-7-3. 1 8 8 8 For information on Printed Marking Tag Options, see Page V7-T8-98. 8 For additional accessories, see Page V7-T8-90. 8 8 8 8 8 8 8 8 8 8 8 Volume 7--Logic Control, Operator Interface and Connectivity Solutions CA08100008E--November 2011 www.eaton.com V7-T8-49 8.1 Terminal Blocks, Fuse Blocks and Fuse Holders IEC--XB Series 8 Technical Data and Specifications 8 Overload and Short-Circuit Protection 8 8 8 8 Terminal Blocks Overload Protection Short-Circuit Protection Only U (V) Individual Interconnected Individual Interconnected Imax. (A) XBPT4FBN 400 1.6W 1.6W 4W 2.5W 10.0 XBPT4FBE 250 1.6W 1.6W 4W 2.5W 6.3 Spring Cage Connection Fuse Terminal Blocks Description XBPT4FBE XBPT4FBN 8 Technical Data in Accordance with IEC Fuse type/dimensions in mm2 G/5 x 20 G/6.3 x 32 8 Maximum current with single arrangement in A 6.3 10 1 8 8 8 8 Maximum Power Dissipation At 73.4F (23C) in accordance with IEC 60 947-7-3 in W 1 Rated surge voltage in kV/contamination class 4/3 6/3 Surge voltage category/insulating material group III/I III/I Stranded with ferrule/with ferrule and plastic sleeve in mm2 0.25-4/0.25-4 0.25-4/0.25-4 Stranded with twin ferrule and plastic sleeve in mm2 0.5 0.5 0.39 (10) 0.39 (10) Connection Capacity Stripping length in inches (mm) 8 8 8 8 8 8 8 Dimensions Approximate Dimensions in Inches (mm) Spring Cage Connection Fuse Terminal Blocks Height for-- Catalog Number Width Length 35 x 7.5 in 35 x 15 in XBPT4FBE 0.24 (6.2) 2.42 (61.5) 2.46 (62.5) 2.76 (70.0) XBPT4FBN 0.32 (8.2) 3.01 (76.5) 2.72 (69.0) 3.01 (76.5) Note 1 The current is determined by the fuse used, the voltage by the selected light indicator. See Page V7-T8-49. 8 8 8 8 8 8 8 8 8 8 8 V7-T8-50 Volume 7--Logic Control, Operator Interface and Connectivity Solutions CA08100008E--November 2011 www.eaton.com 8.1 Terminal Blocks, Fuse Blocks and Fuse Holders IEC--XB Series Contents Disconnect and Component Terminal Blocks Description Page Single Level--Through-Feed . . . . . . . . . . . . . . . . . Single Level--Ground Blocks . . . . . . . . . . . . . . . . . Multi-Conductor Terminal Blocks . . . . . . . . . . . . . . Multi-Conductor Ground Blocks . . . . . . . . . . . . . . Double Level Blocks . . . . . . . . . . . . . . . . . . . . . . . Triple Level Blocks . . . . . . . . . . . . . . . . . . . . . . . . . Fuse Terminal Blocks . . . . . . . . . . . . . . . . . . . . . . . Disconnect and Component Terminal Blocks Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . Technical Data and Specifications . . . . . . . . . . Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . Hybrid Terminal Blocks . . . . . . . . . . . . . . . . . . . . . Mini Spring Cage . . . . . . . . . . . . . . . . . . . . . . . . . . V7-T8-32 V7-T8-37 V7-T8-39 V7-T8-42 V7-T8-44 V7-T8-46 V7-T8-48 V7-T8-52 V7-T8-53 V7-T8-53 V7-T8-54 V7-T8-56 8 8 8 8 8 8 8 8 8 8 8 Disconnect and Component Terminal Blocks 8 Product Description The XBPT knife disconnect terminal blocks feature narrow construction and high current carrying capacity. They also have a test connection parallel to the disconnect point for a 2.3 mm diameter test plug. Potential distribution is easily accomplished with the Plugin bridges. There are front connection spring cage terminal blocks available for multi-conductor connections in the smallest possible space. The XBPT4TG disconnect terminal block accommodates component plugs for resistors, diodes, or capacitors, and fuse plugs with or without indication. 8 8 8 8 Product Selection XBPT25MT Knife Disconnect 8 Disconnect and Component Terminal Blocks Terminal Width Maximum Wire Size IEC 60 947-7-1 in V/A/AWG UL-cUL Ratings in V/A/AWG Color Standard Pack Catalog Number 8 8 Single Level Knife Disconnect 5.2 mm 12 AWG/2.5 mm2 400/16/28-12 600/16/26-12 Gray 50 XBPT25MT 6.2 mm 10 AWG/4 mm2 400/16/28-10 300/6.3/24-10 Gray 50 XBPT4MT 400/16/28-12 600/16/26-12 Gray 50 XBPT25D12MT 400/16/28-12 600/16/26-12 Gray 50 XBPT25D22MT 400/16/28-10 300/6.3/24-10 Gray 50 XBPT4TG 8 10 AWG/4 mm2 400/16/28-10 300/6.3/24-10 Gray 10 XBPCO 8 10 AWG/4 mm2 400/16/28-10 300/6.3/24-10 Black 10 XBPFU 8 300/6.3/24-10 Black 10 XBPFUL24 8 300/6.3/24-10 Black 10 XBPFUL250 8 Three-Wire Knife Disconnect 5.2 mm 12 AWG/2.5 mm2 8 Four-Wire Knife Disconnect 5.2 mm 12 AWG/2.5 mm2 Spring Cage Disconnect/Component Plug 6.2 mm 10 AWG/4 mm2 Component Plug 6.2 mm Fuse Plug 6.2 mm Fuse Plug with Light Indicator for 12-30V, 1-2.5 mA 6.2 mm 10 AWG/4 mm2 400/16/28-10 Fuse Plug with Light Indicator for 110-250V, 0.5-2.5 mA 6.2 mm 10 AWG/4 mm2 8 400/16/28-10 8 8 8 8 Volume 7--Logic Control, Operator Interface and Connectivity Solutions CA08100008E--November 2011 www.eaton.com V7-T8-51 8.1 Terminal Blocks, Fuse Blocks and Fuse Holders IEC--XB Series 8 Accessories 8 Spring Cage Connection Disconnect and Component Terminal Blocks 8 8 8 8 8 8 8 8 8 Standard Pack XBPT25MT Catalog Number XBPT25D12MT Catalog Number XBPT25D22MT Catalog Number XBPT4MT Catalog Number XBPT4TG Catalog Number Description Color End cover Gray -- 10 XBACPT25D12 XBACPT25D22 XBACPT25D22MT 3 3 End cover segment Gray -- 10 -- XBACPT25 XBACPT25 -- -- Partition plate -- -- -- XBATPTD12 XBATPTD22 -- XBATPT4 XBATPT4 Plug-in bridge--for cross connections in the terminal center Red 2 10 XBAFBS25 XBAFBS25 XBAFBS25 XBAFBS26 XBAFBS26 8 8 Number of Positions 3 10 XBAFBS35 XBAFBS35 XBAFBS35 XBAFBS36 XBAFBS36 5 10 XBAFBS55 XBAFBS55 XBAFBS55 XBAFBS56 XBAFBS56 10 10 XBAFBS105 XBAFBS105 XBAFBS105 XBAFBS106 XBAFBS106 50 10 XBAFBS505 XBAFBS505 XBAFBS505 XBAFBS506 XBAFBS506 XBATSPAI4 XBATSPAI4 XBATSPAI4 XBATSPAI4 Test adapter -- -- 10 XBATSPAI4 2.3 mm diameter test plug -- -- -- XBATSMPS-_ 1 XBATSMPS-_ 1 XBATSMPS-_ 1 Modular test plug -- -- 10 XBATSPS5 XBATSPS5 XBATSPS5 XBATSPS6 XBATSPS6 Blank marker strip external labeling White -- 10 XBMZBF5 2 XBMZBF5 2 XBMZBF5 2 XBMZBF6 2 XBMZBF6 2 Blank marker strip center labeling (strip of 10) White -- 10 XBMZB5 2 XBMZB5 2 XBMZB5 2 XBMZB6 2 XBMZB6 2 XBATSMPS-_ 1 XBATSMPS-_ 1 Notes 1 For ordering information, see Page V7-T8-105. 2 For information on Printed Marking Tag Options, see Page V7-T8-98. 3 XBPT4MT and XBPT4TG have an enclosed design. The use of an end cover is not required. For additional accessories, see Page V7-T8-90. 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 V7-T8-52 Volume 7--Logic Control, Operator Interface and Connectivity Solutions CA08100008E--November 2011 www.eaton.com Terminal Blocks, Fuse Blocks and Fuse Holders IEC--XB Series 8.1 Technical Data and Specifications 8 Spring Cage Connection Disconnect and Component Terminal Blocks, XBPT25MT, XBPT25D12MT and XBPT25D22MT Description 8 XBPT25MT XBPT25D12MT XBPT25D22MT 8 Maximum load current in A/cross-section in mm2 16/4 16/4 16/4 8 Rated surge voltage in kV/contamination class 6/3 6/3 6/3 Surge voltage category/insulating material group III/I III/I III/I 8 Stranded with ferrule with plastic sleeve in mm2 0.25-2.5 0.25-2.5 0.25-2.5 8 Stranded with ferrules without plastic sleeve in mm2 0.25-2.5 0.25-2.5 0.25-2.5 Stranded with twin ferrule with plastic sleeve in mm2 0.5 0.5 0.5 0.39 (10) 0.39 (10) 0.39 (10) Technical Data in Accordance with IEC Connection Capacity Stripping length in inches (mm) 8 8 8 Spring Cage Connection Disconnect and Component Terminal Blocks, XBPT25D12MT and XBPT4TG Description 8 XBPT4MT XBPT4TG Maximum load current in A/cross-section in mm2 16/6 16/6 Rated surge voltage in kV/contamination class 6/3 6/3 Surge voltage category/insulating material group III/I III/I 8 Stranded with ferrule with plastic sleeve in mm2 0.25-4 0.25-4 8 Stranded with ferrules without plastic sleeve in mm2 0.25-4 0.25-4 Stranded with twin ferrule with plastic sleeve in mm2 0.5 0.5 0.39 (10) 0.39 (10) 8 Technical Data in Accordance with IEC 8 Connection Capacity Stripping length in inches (mm) 8 8 8 Dimensions Approximate Dimensions in Inches (mm) 8 Spring Cage Connection Disconnect and Component Terminal Blocks 8 Height for-- Length Cover Length 35 x 7.5 in 35 x 15 in 2.38 (60.5) 0.09 (2.2) 1.44 (36.5) 1.73 (44.0) 0.20 (5.2) 2.83 (72.0) 0.09 (2.2) 1.44 (36.5) 1.73 (44.0) 0.20 (5.2) 3.31 (84.0) 0.09 (2.2) 1.44 (36.5) 1.73 (44.0) XBPT4MT 0.24 (6.2) 2.42 (61.5) -- 1.44 (36.5) 1.73 (44.0) XBPT4TG 0.24 (6.2) 2.42 (61.5) -- 1.44 (36.5) 1.73 (44.0) Catalog Number Width XBPT25MT 0.20 (5.2) XBPT25D12MT XBPT25D22MT 8 8 8 8 8 8 8 8 8 8 8 Volume 7--Logic Control, Operator Interface and Connectivity Solutions CA08100008E--November 2011 www.eaton.com V7-T8-53 8.1 8 Terminal Blocks, Fuse Blocks and Fuse Holders IEC--XB Series Contents Hybrid Terminal Blocks Description 8 Page Single Level--Through-Feed . . . . . . . . . . . . . . . . . Single Level--Ground Blocks . . . . . . . . . . . . . . . . . Multi-Conductor Terminal Blocks . . . . . . . . . . . . . Multi-Conductor Ground Blocks . . . . . . . . . . . . . . Double Level Blocks . . . . . . . . . . . . . . . . . . . . . . . Triple Level Blocks . . . . . . . . . . . . . . . . . . . . . . . . . Fuse Terminal Blocks . . . . . . . . . . . . . . . . . . . . . . . Disconnect and Component Terminal Blocks . . . . Hybrid Terminal Blocks Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . Technical Data and Specifications . . . . . . . . . . Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . Mini Spring Cage . . . . . . . . . . . . . . . . . . . . . . . . . . 8 8 8 8 8 8 V7-T8-32 V7-T8-37 V7-T8-39 V7-T8-42 V7-T8-44 V7-T8-46 V7-T8-48 V7-T8-51 V7-T8-55 V7-T8-55 V7-T8-55 V7-T8-56 8 8 8 Hybrid Terminal Blocks 8 Product Description 8 8 8 8 8 8 The XBPU spring cage hybrid terminal blocks offer the best of both worlds. One side offers a spring cage connection and the other side offers the universal screw connection. Use the spring cage connection on the internal (factory) control cabinet side and the screw connection on the end customer (field) side. Ground terminal blocks of the same shape are also available. Product Selection XBPU25D12 8 8 Spring Cage Hybrid Terminal Blocks IEC 60 947-7-1 with ... IEC 60 947-7-2 with ... UL-cUL Ratings with ... Terminal Width Maximum Wire Size Spring in V/A/AWG Screw in V/A/AWG Spring in V/A/AWG Screw in V/A/AWG Spring in V/A/AWG Screw in V/A/AWG Color Std. Pack Catalog Number 5.2 mm 12 AWG/ 2.5 mm2 800/28/28-12 800/28/26-14 -- -- 600/15/28-12 600/15/26-12 Gray 50 XBPU25D12 Color Std. Pack Catalog Number 50 XBPU25D12PE 8 8 8 XBPU25D12PE Spring Cage Hybrid Ground Blocks IEC 60 947-7-1 with ... IEC 60 947-7-2 with ... UL-cUL Ratings with ... 8 Terminal Width Maximum Wire Size Spring in V/A/AWG Screw in V/A/AWG Spring in V/A/AWG Screw in V/A/AWG Spring in V/A/AWG Screw in V/A/AWG 8 5.2 mm 12 AWG/ 2.5 mm2 -- -- --/--/28-12 --/--/26-14 --/--/28-12 --/--/28-12 Green/ Yellow 8 8 8 8 8 V7-T8-54 Volume 7--Logic Control, Operator Interface and Connectivity Solutions CA08100008E--November 2011 www.eaton.com 8.1 Terminal Blocks, Fuse Blocks and Fuse Holders IEC--XB Series Accessories 8 Spring Cage Hybrid Terminal/Ground Blocks Description Color Number of Positions Standard Pack XBPU25D12 Catalog Number XBPU25D12PE Catalog Number End cover Gray -- 10 XBACPU25D12 XBACPU25D12 Plug-in bridge--for cross connections in the terminal center Red 2 10 XBAFBS25 XBAFBS25 3 10 XBAFBS35 XBAFBS35 5 10 XBAFBS55 XBAFBS55 10 10 XBAFBS105 XBAFBS105 50 10 XBAFBS505 XBAFBS505 Test adapter -- -- 10 XBATSPAI4 -- 2.3 mm diameter test plug -- -- -- XBATSMPS-_ 1 -- Modular test plug -- -- 10 XBATSPS5 -- Blank marker strip external labeling White -- 10 XBMZBF5 2 XBMZBF5 2 Blank marker strip center labeling (strip of 10) White -- 10 XBMZB5 2 XBMZB5 2 8 8 8 8 8 8 8 8 8 Technical Data and Specifications 8 Spring Cage Hybrid Blocks 8 Description XBPU25D12 XBPU25D12PE Maximum load current in A/cross-section in mm2 28/4 -- Rated surge voltage in kV/contamination class 8/3 8/3 Surge voltage category/insulating material group III/I III/I 8 Stranded with ferrule with plastic sleeve in mm2 0.25-2.5 0.25-2.5 8 Stranded with ferrules without plastic sleeve in mm2 0.25-2.5 0.25-2.5 Stranded with twin ferrule with plastic sleeve in mm2 0.5-1 0.5-1 0.39 (10) 0.39 (10) 8 Technical Data in Accordance with IEC 8 Connection Capacity Stripping length in inches (mm) 8 8 8 Dimensions 8 Approximate Dimensions in Inches (mm) 8 Spring Cage Hybrid Blocks Height for-- Length Cover Length 35 x 7.5 in 35 x 15 in 0.20 (5.2) 2.57 (65.3) 0.09 (2.2) 1.69 (42.8) 1.98 (50.3) 0.20 (5.2) 2.57 (65.3) 0.09 (2.2) 1.69 (42.8) 1.98 (50.3) Catalog Number Width XBPU25D12 XBPU25D12PE 8 8 8 Notes 1 For ordering information, see Page V7-T8-105. 2 For information on Printed Marking Tag Options, see Page V7-T8-98. 8 For additional accessories, see Page V7-T8-90. 8 8 8 8 8 Volume 7--Logic Control, Operator Interface and Connectivity Solutions CA08100008E--November 2011 www.eaton.com V7-T8-55 8.1 8 Terminal Blocks, Fuse Blocks and Fuse Holders IEC--XB Series Contents Mini Spring Cage Description 8 Page Single Level--Through-Feed . . . . . . . . . . . . . . . . . Single Level--Ground Blocks . . . . . . . . . . . . . . . . Multi-Conductor Terminal Blocks . . . . . . . . . . . . . Multi-Conductor Ground Blocks . . . . . . . . . . . . . . Double Level . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Triple Level Sensor/Actuator . . . . . . . . . . . . . . . . . Fuse Terminal Blocks . . . . . . . . . . . . . . . . . . . . . . . Disconnect and Component Terminal Blocks . . . . High Current Blocks . . . . . . . . . . . . . . . . . . . . . . . Mini Spring Cage Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . Technical Data and Specifications . . . . . . . . . . Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 8 8 8 8 8 V7-T8-5 V7-T8-10 V7-T8-12 V7-T8-14 V7-T8-16 V7-T8-18 V7-T8-21 V7-T8-24 V7-T8-27 V7-T8-57 V7-T8-57 V7-T8-57 8 8 8 Mini Spring Cage 8 Product Description 8 8 The XB miniature terminal blocks have a connection cross-section from 1.5 mm2 through 4 mm2 and mount on 15 mm DIN rail. There is an opening for bridging with a fixed bridge in the center of the terminal blocks. These miniature terminal blocks also offer the same accessories that you would find with the larger blocks--including marking tags, end covers, end stop and ground blocks. 8 8 Product Selection 8 XBMPK15 8 Mini Spring Cage Terminal Blocks Terminal Width Maximum Wire Size IEC 60 947-7-1 in V/A/AWG IEC 60 947-7-2 in V/A/AWG UL-cUL Ratings in V/A/AWG 5.2 mm 14 AWG/1.5 mm2 800/24/26-14 -- 600/15/26-14 8 Color Standard Pack Catalog Number Gray 50 XBMPK15 Blue 50 XBMPK15BU Color Standard Pack Catalog Number 50 XBMPK15PE 8 8 8 XBMPK15PE 8 Mini Spring Cage Ground Blocks Terminal Width Maximum Wire Size IEC 60 947-7-1 in V/A/AWG IEC 60 947-7-2 in V/A/AWG UL-cUL Ratings in V/A/AWG 5.2 mm 14 AWG/1.5 mm2 -- --/--/26-14 --/--/26-14 8 Green/ Yellow 8 8 8 XBMPKK15 8 Mini Spring Cage Terminal Blocks--Double Level Terminal Width Maximum Wire Size IEC 60 947-7-1 in V/A/AWG UL-cUL Ratings in V/A/AWG Color Standard Pack Catalog Number 5.2 mm 14 AWG/1.5 mm2 500/20/26-14 600/15/26-14 Gray 50 XBMPKK15 8 8 V7-T8-56 Volume 7--Logic Control, Operator Interface and Connectivity Solutions CA08100008E--November 2011 www.eaton.com Terminal Blocks, Fuse Blocks and Fuse Holders IEC--XB Series 8.1 Accessories 8 Mini Spring Cage Terminal/Ground Blocks Description Color Number of Positions Standard Pack XBMPK15 Catalog Number XBMPK15PE Catalog Number XBMPKK15 Catalog Number End cover Gray -- 10 XBACMPK15 XBACMPK15 XBACMPKK15 Fixed bridge -- 2 10 XBAFBR25N -- XBAFBR25N Separating plate -- -- 10 XBATMPKK15 -- XBATMPKK15 Blank marker strip White -- 10 XBMZBF5 1 XBMZBF5 1 XBMZBF5 1 8 8 8 8 8 Technical Data and Specifications 8 Mini Spring Cage Terminal/Ground Blocks Description 8 XBMPK15 XBMPK15PE XBMPKK15 Maximum load current in A/cross-section in mm2 24/2.5 -- 20/2.5 Rated surge voltage in kV/contamination class 8/3 8/3 6/3 Surge voltage category/insulating material group III/I III/I III/I 8 Stranded with ferrule with plastic sleeve in mm2 0.25-1.5 0.25-1.5 0.25-1.5 8 Stranded with ferrule without plastic sleeve in mm2 0.25-1.5 0.25-1.5 0.25-1.5 Stranded with twin ferrule with plastic sleeve in mm2 -- -- -- 0.35 (9) 0.35 (9) 0.35 (9) 8 Technical Data in Accordance with IEC 8 Connection Cross-Section Stripping length in Inches (mm) 8 8 8 Dimensions Approximate Dimensions in Inches (mm) 8 Mini Spring Cage Terminal/Ground Blocks 8 Height for-- Length Cover Length 15 x 5.5 in 35 x 7.5 in 35 x 15 in 1.57 (40.0) 0.04 (1.1) 1.36 (34.5) -- -- 1.36 (34.5) -- -- 1.65 (42.0) 1.67 (42.5) 1.97 (50.0) Catalog Number Width XBMPK15 0.20 (5.2) XBMPK15PE 0.20 (5.2) 1.57 (40.0) 0.04 (1.1) XBMPKK15 0.20 (5.2) 3.35 (85.0) 0.04 (1.1) 8 8 8 Notes 1 For information on Printed Marking Tag Options, see Page V7-T8-98. 8 For additional accessories, see Page V7-T8-90. 8 8 8 8 8 8 8 8 8 Volume 7--Logic Control, Operator Interface and Connectivity Solutions CA08100008E--November 2011 www.eaton.com V7-T8-57 8.1 8 Terminal Blocks, Fuse Blocks and Fuse Holders IEC--XB Series Contents Pluggable Spring Cage Terminal Blocks Description 8 Page Pluggable Spring Cage Terminal Blocks Connection Terminal Blocks . . . . . . . . . . . . . . . Connection Plugs . . . . . . . . . . . . . . . . . . . . . . . Connection Receptacles . . . . . . . . . . . . . . . . . Connection Accessories . . . . . . . . . . . . . . . . . 8 8 V7-T8-59 V7-T8-62 V7-T8-64 V7-T8-66 Drawings Online 8 8 8 8 8 8 8 Pluggable Spring Cage Terminal Blocks Overview 8 Product Description Application Description Features The pluggable spring cage connection terminal blocks allow signal and power wiring to be made pluggable. This complete pluggable system has a spring that provides maximum connection space in a space-saving design. The pluggable system accommodates stranded conductors with a nominal cross-section of 2.5 mm2, with or without ferrules. For applications requiring pluggable wiring up to a rated current of 32A and a rated voltage of 800V. The integrated overspring meets the most stringent vibration requirements. Also ideal where safety is a concern and flexibility is required. The basic terminal blocks and the plugs are finger-safe, which also means the supply voltage can be input via either the terminal blocks or the plugs. With the XBAPSC receptacles, plug-in contacts can be accommodated safely in cable ducts and distributor shafts using minimal space. A test hole can accommodate a 2.3 mm diameter test plug in each receptacle, providing a practical solution. The XBAPSP plugs are intended for connecting one wire, while the XBAPSPDB plugs are designed to connect two wires and provide an optional bridge. 8 8 8 8 8 8 8 8 8 8 8 8 8 Standards and Certifications Space-saving design Powerful contact Finger-safe Pluggability UL recognized--File No. E67464 CE approved LVD 1: EN 60947-7-1 EN 60947-7-2 EN 60998-2-3 EN 60352-4/A1 ATEX approval (Eex e applications) Note 1 Not all standards apply to all terminal blocks. Contact Eaton for details. 8 8 8 8 8 V7-T8-58 Volume 7--Logic Control, Operator Interface and Connectivity Solutions CA08100008E--November 2011 www.eaton.com 8.1 Terminal Blocks, Fuse Blocks and Fuse Holders IEC--XB Series Contents Connection Terminal Blocks Description Page Connection Terminal Blocks Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . Technical Data and Specifications . . . . . . . . . . Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . Connection Plugs . . . . . . . . . . . . . . . . . . . . . . . . . Connection Receptacles . . . . . . . . . . . . . . . . . . . . Connection Accessories . . . . . . . . . . . . . . . . . . . . 8 8 V7-T8-60 V7-T8-60 V7-T8-61 V7-T8-62 V7-T8-64 V7-T8-66 8 8 8 8 8 8 8 8 8 Connection Terminal Blocks 8 Product Description Contact to the DIN rail is made by simply snapping the terminal block onto the rail. These blocks act as the stationary position of the pluggable terminal blocks. 8 8 8 Product Selection XBPT25P 8 Pluggable Spring Cage Connection Terminal Blocks Terminal Width Maximum Wire Size IEC 61 984 in V/A/AWG UL-cUL Ratings in V/A/AWG Color Standard Pack Catalog Number 8 12 AWG/2.5 mm2 500/24/28-12 300/20/26-12 Gray 50 XBPT25P 8 12 AWG/2.5 mm2 500/24/28-12 300/20/26-12 Gray 50 XBPT25PD12 Single Level 5.2 mm 8 Three-Wire 5.2 mm 8 8 8 8 8 8 8 8 8 8 8 Volume 7--Logic Control, Operator Interface and Connectivity Solutions CA08100008E--November 2011 www.eaton.com V7-T8-59 8.1 Terminal Blocks, Fuse Blocks and Fuse Holders IEC--XB Series 8 Accessories 8 Pluggable Spring Cage Connection Terminal Blocks Standard Pack XBPT25P Catalog Number XBPT25PD12 Catalog Number XBACPT25D12 Description Color Number of Positions 8 End cover Gray -- 10 XBACPT25 End cover segment Gray -- 10 -- XBASPT25 8 Partition plate -- -- 10 XBATPT4 XBATPTD12 Plug-in bridge--for cross connections in the terminal center Red 8 8 8 8 8 8 2 10 XBAFBS25 XBAFBS25 3 10 XBAFBS35 XBAFBS35 5 10 XBAFBS55 XBAFBS55 10 10 XBAFBS105 XBAFBS105 XBAFBS505 50 10 XBAFBS505 Test adapter -- -- 10 XBATSPAI4 XBATSPAI4 2.3 mm diameter test plug -- -- -- XBATSMPS-_ 1 XBATSMPS-_ 1 Modular test plug -- -- 10 XBATSPS5 XBATSPS5 Blank marker strip external labeling White -- 10 XBMZBF5 2 XBMZBF5 2 Blank marker strip center labeling (strip of 10) White -- 10 XBMZB5 2 XBMZB5 2 8 8 Technical Data and Specifications Pluggable Spring Cage Connection Terminal Blocks Derating Curve for Pluggable Terminal Blocks Description XBPT25P and XBPT25PD12 XBPT25P XBPT25PD12 8 Technical Data in Accordance with IEC Maximum load current in A/cross-section in mm2 24/4 24/4 8 Rated surge voltage in kV/contamination class 6/3 6/3 Surge voltage category/insulating material group III/I III/I 8 Stranded with ferrule with plastic sleeve in mm2 0.25-2.5 0.25-2.5 Stranded with ferrules without plastic sleeve in mm2 0.25-2.5 0.25-2.5 8 Stranded with twin ferrule with plastic sleeve in mm2 0.5 0.5 0.39 (10) 0.39 (10) 8 25 Connection Capacity Stripping length in inches (mm) 8 8 5 pos. 10 pos. 20 2 pos. 15 pos. 15 10 5 0 8 8 Maximum Load Current - A 8 0 20 40 60 80 Ambient Temperature - C 100 Notes 1 For ordering information, see Page V7-T8-105. 2 For information on Printed Marking Tag Options, see Page V7-T8-98. For additional accessories, see Page V7-T8-90. 8 8 8 8 8 8 8 8 V7-T8-60 Volume 7--Logic Control, Operator Interface and Connectivity Solutions CA08100008E--November 2011 www.eaton.com 120 Terminal Blocks, Fuse Blocks and Fuse Holders IEC--XB Series 8.1 Dimensions Approximate Dimensions in Inches (mm) 8 Pluggable Spring Cage Connection Terminal Blocks--Without Plug 8 Catalog Number Length Cover Length Height for-- Width 35 x 7.5 in 35 x 15 in XBPT25P 0.20 (5.2) 1.91 (48.5) 0.09 (2.2) 1.44 (36.5) 1.73 (44.0) XBPT25PD12 0.20 (5.2) 2.38 (60.5) 0.09 (2.2) 1.44 (36.5) 1.73 (44.0) 8 8 8 XBPT25P 8 1.99 (50.5) 8 8 8 2.42 (61.5) 8 8 8 8 8 XBPT25PD12 2.42 (61.5) 8 8 8 8 2.42 (61.5) 8 8 8 8 8 8 8 8 8 8 8 8 Volume 7--Logic Control, Operator Interface and Connectivity Solutions CA08100008E--November 2011 www.eaton.com V7-T8-61 8.1 8 Terminal Blocks, Fuse Blocks and Fuse Holders IEC--XB Series Contents Connection Plugs Description 8 Page Connection Terminal Blocks . . . . . . . . . . . . . . . . . Connection Plugs Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . Technical Data and Specifications . . . . . . . . . . Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . Connection Receptacles . . . . . . . . . . . . . . . . . . . . Connection Accessories . . . . . . . . . . . . . . . . . . . . 8 8 8 V7-T8-59 V7-T8-63 V7-T8-63 V7-T8-63 V7-T8-64 V7-T8-66 8 8 8 8 8 8 Connection Plugs 8 Product Description 8 8 Just like the basic terminal blocks, the plugs also offer the perfect solution for every application. The XBAPSP25_ plugs are designed for connecting one conductor. The XBAPSPDB25_ plug is designed for connecting two conductors and provides an additional bridging option. 8 8 Product Selection 8 XBAPSP25_ 8 Spring Cage Connection Plugs, Single, Not Bridgeable Terminal Width Maximum Wire Size Connection Data in V/A/AWG UL-cUL Ratings in V/A/AWG Color 5.2 mm 12 AWG/2.5 mm2 500/24/28-12 300/20/26-12 Gray Number of Positions Standard Pack Catalog Number 1 25 XBAPSP251 2 25 XBAPSP252 3 25 XBAPSP253 4 25 XBAPSP254 8 5 25 XBAPSP255 6 25 XBAPSP256 8 7 25 XBAPSP257 8 25 XBAPSP258 8 9 25 XBAPSP259 10 25 XBAPSP2510 11 10 XBAPSP2511 12 10 XBAPSP2512 8 8 8 8 8 8 8 8 8 V7-T8-62 Volume 7--Logic Control, Operator Interface and Connectivity Solutions CA08100008E--November 2011 www.eaton.com 8.1 Terminal Blocks, Fuse Blocks and Fuse Holders IEC--XB Series Spring Cage Connection Plugs, Double, Bridgeable XBAPSPDB25_ 8 Terminal Width Maximum Wire Size Connection Data in V/A/AWG UL-cUL Ratings in V/A/AWG Color Number of Positions Standard Pack Catalog Number 5.2 mm 12 AWG/2.5 mm2 500/24/28-12 300/20/26-12 Gray 1 25 XBAPSPDB251 2 25 XBAPSPDB252 3 25 XBAPSPDB253 4 25 XBAPSPDB254 5 25 XBAPSPDB255 6 25 XBAPSPDB256 7 25 XBAPSPDB257 8 25 XBAPSPDB258 9 25 XBAPSPDB259 10 25 XBAPSPDB2510 11 10 XBAPSPDB2511 12 10 XBAPSPDB2512 8 8 8 8 8 8 8 8 Accessories 8 Spring Cage Connection Plugs 8 Description Color Plug-in bridge--for cross connections in the terminal center Red Number of Positions Standard Pack XBAPSP25_ Catalog Number XBAPSPDB25_ Catalog Number 2 10 -- XBAFBS25 3 10 -- XBAFBS35 5 10 -- XBAFBS55 XBAFBS105 10 10 -- Snap-lock fitting and strain relief Orange 2 10 XBAPPRZ XBAPPRZ Snap-lock fitting Orange 1 10 XBAPPR XBAPPR Orange 2 10 XBAPPR2 XBAPPR2 Black 2 10 XBAPPZ2 XBAPPDZ2 Black 4 10 XBAPPZ4 XBAPPDZ4 White -- 10 XBMZBF5 1 XBMZBF5 1 Strain relief Blank marker strip 8 8 8 8 8 8 8 8 Technical Data and Specifications 8 Spring Cage Connection Plugs Description XBAPSP25_ XBAPSPDB25_ 24/4 24/4 8 Technical Data in Accordance with IEC Maximum load current in A/cross-section in mm2 Rated surge voltage in kV/contamination class 6/3 6/3 Surge voltage category/insulating material group III/I III/I Stranded with ferrule with plastic sleeve in mm2 0.25-2.5 0.25-2.5 Stranded with ferrules without plastic sleeve in mm2 0.25-2.5 0.25-2.5 Stranded with twin ferrule with plastic sleeve in mm2 0.5 0.5 0.39 (10) 0.39 (10) 8 8 8 Connection Capacity Stripping length in inches (mm) 8 8 8 Dimensions 8 See Page V7-T8-61 for dimensions. 8 Notes 1 For information on Printed Marking Tag Options, see Page V7-T8-98. 8 For additional accessories, see Page V7-T8-90. Volume 7--Logic Control, Operator Interface and Connectivity Solutions CA08100008E--November 2011 www.eaton.com V7-T8-63 8.1 8 Terminal Blocks, Fuse Blocks and Fuse Holders IEC--XB Series Contents Connection Receptacles Description 8 Page Connection Terminal Blocks . . . . . . . . . . . . . . . . . Connection Plugs . . . . . . . . . . . . . . . . . . . . . . . . . Connection Receptacles Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . Technical Data and Specifications . . . . . . . . . . Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . Connection Accessories . . . . . . . . . . . . . . . . . . . . 8 8 8 V7-T8-59 V7-T8-62 V7-T8-65 V7-T8-65 V7-T8-65 V7-T8-66 8 8 8 8 8 8 Connection Receptacles 8 Product Description 8 8 With the XBAPSC25_, Plug-in contacts can be accommodated safely in cable ducts and distributor shafts without using much space. The standard strain reliefs can also be used. Large-surface labeling makes it possible to mark the terminal points and the entire receptacle. A test hole can accommodate a 2.3 mm diameter test plug in each receptacle element, providing a practical solution. 8 8 Product Selection 8 XBAPSC25_ 8 Pluggable Spring Connection Receptacles Terminal Width Maximum Wire Size Connection Data in V/A/AWG UL-cUL Ratings in V/A/AWG Color 5.2 mm 12 AWG/2.5 mm2 500/24/28-12 300/20/26-12 Gray Number of Positions Standard Pack Catalog Number 2 25 XBAPSC252 3 25 XBAPSC253 8 4 25 XBAPSC254 5 25 XBAPSC255 8 6 25 XBAPSC256 7 25 XBAPSC257 8 8 25 XBAPSC258 9 25 XBAPSC259 10 25 XBAPSC2510 11 10 XBAPSC2511 12 10 XBAPSC2512 8 8 8 8 8 8 8 8 8 V7-T8-64 Volume 7--Logic Control, Operator Interface and Connectivity Solutions CA08100008E--November 2011 www.eaton.com Terminal Blocks, Fuse Blocks and Fuse Holders IEC--XB Series 8.1 Accessories 8 Pluggable Spring Connection Receptacles Description Color Number of Positions Standard Pack XBAPSC25_ Catalog Number 2.3 mm diameter test plug Red -- -- XBATSMPS-_ 1 Strain relief Black 2 10 XBAPPDZ2 Black 4 10 XBAPPDZ4 White -- 10 XBMZBF5 2 Blank marker strip 8 8 8 8 8 Technical Data and Specifications 8 Spring Cage Connection Plugs Description 8 XBAPSP25_ 8 Technical Data in Accordance with IEC Maximum load current in A/cross-section in mm2 24/4 Rated surge voltage in kV/contamination class 6/3 Surge voltage category/insulating material group III/I 8 Stranded with ferrule with plastic sleeve in mm2 0.25-2.5 Stranded with ferrules without plastic sleeve in mm2 0.25-2.5 8 Stranded with twin ferrule with plastic sleeve in mm2 0.5 8 Connection Capacity Stripping length in inches (mm) 8 0.39 (10) 8 8 Dimensions Approximate Dimensions in Inches (mm) 8 Spring Cage Connection Plugs 8 Catalog Number Width Length Cover Length Height XBAPSP25_ 0.20 (5.2) 1.46 (37.2) 0.09 (2.2) 0.71 (18.0) 8 8 Receptacle Widths 8 Catalog Number Width Catalog Number Width XBAPSC252 0.41 (10.4) XBAPSC258 1.64 (41.6) XBAPSC253 0.61 (15.6) XBAPSC259 1.84 (46.8) XBAPSC254 0.82 (20.8) XBAPSC2510 2.05 (52.0) XBAPSC255 1.02 (26.0) XBAPSC2511 2.25 (57.2) XBAPSC256 1.23 (31.2) XBAPSC2512 2.46 (62.4) XBAPSC257 1.43 (36.4) 8 8 8 8 8 Notes 1 For ordering information, see Page V7-T8-105. 2 For information on Printed Marking Tag Options, see Page V7-T8-98. 8 For additional accessories, see Page V7-T8-90. 8 8 8 8 Volume 7--Logic Control, Operator Interface and Connectivity Solutions CA08100008E--November 2011 www.eaton.com V7-T8-65 8.1 Terminal Blocks, Fuse Blocks and Fuse Holders IEC--XB Series 8 Connection Accessories 8 The pluggable XBPT series features an extensive range of application-oriented accessories. Strain reliefs are available for the plugs and 8 8 8 Product Description the plug housing as an option and hooks onto the terminal block housing when the plug is snapped on. Product Selection 8 Pluggable Spring Cage Connection Accessories 8 8 can be snapped on at the required points as an option. The snap-lock fitting can be used for all plug variants. It is snapped into the outside of Description XBAPPZ2 Strain relief for single plugs Number of Positions Standard Pack Catalog Number 2 10 XBAPPZ2 4 10 XBAPPZ4 2 10 XBAPPDZ2 4 10 XBAPPDZ4 8 8 8 XBAPPDZ4 Strain relief for double plugs and receptacles 8 8 XBAPPR2 Snap-lock fitting for plugs 8 1 10 XBAPPR 2 10 XBAPPR2 2 10 XBAPPRZ 8 8 XBAPPRZ Snap-lock fitting and strain relief for plugs 8 8 8 Strain Relief Snap-Lock Fitting 8 8 8 8 8 8 Optional Accessory Recommendations 8 8 8 Number of Positions Receptacle Strain Relief 2-4 XBAPPZ2 5-10 XBAPPZ4 or (2) XBAPPZ2 11-15 (2) XBAPPZ4 or (4) XBAPPZ2 8 8 V7-T8-66 Volume 7--Logic Control, Operator Interface and Connectivity Solutions CA08100008E--November 2011 www.eaton.com Terminal Blocks, Fuse Blocks and Fuse Holders IEC--XB Series 8.1 Contents IDC Terminal Blocks Description Page IDC Terminal Blocks Single Level . . . . . . . . . . . . . . . . . . . . . . . . . . . Multi-Conductor . . . . . . . . . . . . . . . . . . . . . . . . Double Level . . . . . . . . . . . . . . . . . . . . . . . . . . . Fuse Terminal Blocks . . . . . . . . . . . . . . . . . . . . Disconnect and Component Terminal Blocks . . Hybrid Terminal Blocks . . . . . . . . . . . . . . . . . . . 8 8 V7-T8-68 V7-T8-70 V7-T8-73 V7-T8-75 V7-T8-77 V7-T8-79 8 8 8 8 Drawings Online 8 8 8 8 8 IDC (Insulation Displacement Connection) Terminal Blocks Overview Product Description The superior design of Eaton's Insulation Displacement Connection (IDC) technology terminal blocks reduces wiring installation time and labor, especially in high-volume applications. IDC terminal blocks are suited for applications in automated equipment and machine tools, packaging and material handling machinery, railway/ mass transit systems, petrochemical, and any other application requiring highvolume connections for lowvoltage control and signal circuitry where labor cost reduction and ease of assembly is desired. These terminal blocks are designed for long-term use under demanding conditions. The XBQT Series allows for wire to be connected without any prior stripping. The quick connection provides up to 60% reduction in wiring time. One turn of a standard screwdriver results in a simple, fast and reliable connection. Application Description Features The XBQT is operated with a standard screwdriver. The switching states are clearly signaled by engagement points in the start and end positions. Solid and stranded wires of 0.25 to 2.5 mm2 can be wired without the use of ferrules. Stripping the wire is not required--the wire's insulation is cut open when it is properly connected. The wire is securely placed in the end position where it makes large-area, gas-tight contact. Connections are made in seconds! 8 Quick connection capability Global acceptance Flexible plug-in bridge system Large surface area for marking Standardized testing system Standards and Certifications UL recognized--File No. E67464 CE approved LVD 1 EN 60947-7-1 EN 60947-7-2 EN 60998-2-3 EN 60352-4/A1 ATEX approval (Eex e applications) 8 8 8 8 8 8 8 8 8 8 8 8 Note 1 Not all standards apply to all terminal blocks. Contact Eaton for details. 8 8 8 8 8 8 Volume 7--Logic Control, Operator Interface and Connectivity Solutions CA08100008E--November 2011 www.eaton.com V7-T8-67 8.1 8 Terminal Blocks, Fuse Blocks and Fuse Holders IEC--XB Series Contents Single Level Description 8 Page Single Level Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . Technical Data and Specifications . . . . . . . . . . Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . Multi-Conductor . . . . . . . . . . . . . . . . . . . . . . . . . . Double Level . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Fuse Terminal Blocks . . . . . . . . . . . . . . . . . . . . . . . Disconnect and Component Terminal Blocks . . . . Hybrid Terminal Blocks . . . . . . . . . . . . . . . . . . . . . 8 8 8 8 V7-T8-69 V7-T8-69 V7-T8-69 V7-T8-70 V7-T8-73 V7-T8-75 V7-T8-77 V7-T8-79 8 8 8 8 8 Single Level 8 Product Description 8 8 8 8 The XBQT IDC terminal block has the fastest connection time in a compact design. The space-saving front connection design offers additional space for wiring between the cable ducts. The double bridge shaft can 8 Product Selection 8 XBQT25 accommodate individual chain bridging and step-down bridging from other terminal blocks. The XBQT ground blocks are the same shape as the feed-through terminal blocks with the same wide range of cross-sections available. They easily snap onto the DIN rail to make a reliable mechanical and electrical contact that meets all requirements of IEC 60-947-7-2. IDC--Single Level Terminal Blocks 8 Terminal Width Maximum Wire Size Connection Data in V/A/AWG EN 50 019 1 in V/A/AWG UL-cUL Ratings in V/A/AWG 8 5.2 mm 16 AWG/1.5 mm2 800/17.5/24-16 550/16/24-16 600/10/24-16 8 6.2 mm 14 AWG/2.5 mm2 800/24/20-14 -- 600/15/20-14 Color Standard Pack Catalog Number Gray 50 XBQT15 Blue 50 XBQT15BU Gray 50 XBQT25 Blue 50 XBQT25BU Color Standard Pack Catalog Number 8 8 8 XBQT15PE 8 8 IDC--Single Level Terminal Ground Blocks Terminal Width Maximum Wire Size Connection Data in V/A/AWG EN 50 019 1 in V/A/AWG 5.2 mm 16 AWG/1.5 mm2 --/--/24-16 --/--/24-16 --/--/24-16 Green/Yellow 50 XBQT15PE 6.2 mm 14 AWG/2.5 mm2 --/--/20-14 -- --/--/20-14 Green/Yellow 50 XBQT25PE UL-cUL Ratings in V/A/AWG 8 Note 1 EU type--examination certificate number: KEMA 05ATEX2157 U (XBQT15), KEMA 05ATEX2160 U (XBQT25). 8 8 8 V7-T8-68 Volume 7--Logic Control, Operator Interface and Connectivity Solutions CA08100008E--November 2011 www.eaton.com 8.1 Terminal Blocks, Fuse Blocks and Fuse Holders IEC--XB Series Accessories 8 IDC--Single Level Terminal/Ground Blocks XBQT25 Catalog Number XBQT15PE Catalog Number XBQT25PE Catalog Number 8 Description Color Number of Positions Standard Pack XBQT15 Catalog Number End cover Gray -- 10 XBACQT15 XBACQT25 XBACQT15 XBACQT25 Partition plate -- -- 10 XBATQT25 XBATQT25 XBATQT25 XBATQT25 Plug-in bridge Red 2 10 XBAFBS25 XBAFBS26 XBAFBS25 XBAFBS26 3 10 XBAFBS35 XBAFBS36 XBAFBS35 XBAFBS36 5 10 XBAFBS55 XBAFBS56 XBAFBS55 XBAFBS56 10 10 XBAFBS105 XBAFBS106 XBAFBS105 XBAFBS106 8 8 8 8 8 50 10 XBAFBS505 XBAFBS506 XBAFBS505 XBAFBS506 Test adapter -- -- 10 XBATSPAI4 XBATSPAI4 XBATSPAI4 XBATSPAI4 2.3 mm diameter test plug -- -- -- XBATSMPS-_ 1 XBATSMPS-_ 1 XBATSMPS-_ 1 XBATSMPS-_ 1 Modular test plug -- -- 10 XBATSPS5 XBATSPS6 XBATSPS5 XBATSPS6 Blank marker strip center and external marking White -- 10 XBMZBF5 2 XBMZBF6 2 XBMZBF5 2 XBMZBF6 2 8 Blank marker strip center labeling (strip of 10) White -- 10 XBMZB5 2 XBMZB6 2 XBMZB5 2 XBMZB6 2 8 8 8 8 Technical Data and Specifications 8 IDC--Single Level Terminal/Ground Blocks Description XBQT15 XBQT25 XBQT15PE XBQT25PE 8 Technical Data in Accordance with IEC Maximum load current in A/cross-section in mm2 17.5/1.5 24/2.5 -- -- Rated surge voltage in kV/contamination class 8/3 8/3 8/3 8/3 Surge voltage category/insulating material group III/I III/I III/I III/I 8 Core insulation PVC/PE PVC/PE PVC/PE PVC/PE 8 Single/multiple/fine strand in mm2 1.5 2.5 1.5 2.5 Halogen-free in mm2 1.5 2.5 1.5 2.5 24-16 (0.25-0.34) 20-14 (--) 24-16 (0.25-0.34) 20-14 (--) 0.25-1.5 0.5-2.5 0.25-1.5 0.5-2.5 8 Connection Cross-Section Fine strand/superfine strand in AWG (mm2) Repeated connections minimum 100 x in mm2 8 8 8 8 Dimensions Approximate Dimensions in Inches (mm) 8 IDC--Single Level Terminal/Ground Blocks 8 Catalog Number Length Cover Length Height for-- Width 35 x 7.5 in 35 x 15 in XBQT15 0.20 (5.2) 2.31 (58.8) 0.09 (2.2) 1.55 (39.3) 1.84 (46.8) XBQT25 0.24 (6.2) 2.46 (62.6) 0.09 (2.2) 1.55 (39.3) 1.84 (46.8) XBQT15PE 0.20 (5.2) 2.31 (58.8) 0.09 (2.2) 1.55 (39.3) 1.84 (46.8) XBQT25PE 0.24 (6.2) 2.46 (62.6) 0.09 (2.2) 1.55 (39.3) 1.84 (46.8) 8 8 8 Notes 1 For ordering information, see Page V7-T8-105. 2 For information on Printed Marking Tag Options, see Page V7-T8-98. 8 For additional accessories, see Page V7-T8-90. 8 8 8 Volume 7--Logic Control, Operator Interface and Connectivity Solutions CA08100008E--November 2011 www.eaton.com V7-T8-69 8.1 8 Terminal Blocks, Fuse Blocks and Fuse Holders IEC--XB Series Contents Multi-Conductor Description 8 Page Single Level . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Multi-Conductor Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . Technical Data and Specifications . . . . . . . . . . Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . Double Level . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Fuse Terminal Blocks . . . . . . . . . . . . . . . . . . . . . . . Disconnect and Component Terminal Blocks . . . . Hybrid Terminal Blocks . . . . . . . . . . . . . . . . . . . . . 8 8 8 8 V7-T8-68 V7-T8-71 V7-T8-72 V7-T8-72 V7-T8-73 V7-T8-75 V7-T8-77 V7-T8-79 8 8 8 8 8 Multi-Conductor 8 Product Description 8 8 8 8 8 8 The XBQT IDC terminal block has the fastest connection time in a compact design. The space-saving front connection design offers additional space for wiring between the cable ducts. The double bridge shaft can accommodate individual chain bridging and step-down bridging from other terminal blocks. The XBQT ground blocks are the same shape as the feed-through terminal blocks with the same wide range of cross-sections available. They easily snap onto the DIN rail to make a reliable mechanical and electrical contact that meets all requirements of IEC 60-947-7-2. Product Selection XBQT25D12 8 8 IDC--Multi-Conductor Terminal Blocks, Three-Wire Terminal Width Maximum Wire Size Connection Data in V/A/AWG EN 50 019 1 in V/A/AWG UL-cUL Ratings in V/A/AWG 5.2 mm 16 AWG/1.5 mm2 800/17.5/24-16 550/16/24-16 600/10/24-16 6.2 mm 14 AWG/2.5 mm2 800/24/20-14 -- 600/15/20-14 8 8 XBQT15D22PE Color Standard Pack Catalog Number Gray 50 XBQT15D12 Blue 50 XBQT15D12BU Gray 50 XBQT25D12 Blue 50 XBQT25D12BU Color Standard Pack Catalog Number IDC--Multi-Conductor Terminal Blocks, Four-Wire 8 Terminal Width Maximum Wire Size Connection Data in V/A/AWG EN 50 019 1 in V/A/AWG UL-cUL Ratings in V/A/AWG 8 5.2 mm 16 AWG/1.5 mm2 800/17.5/24-16 550/16/24-16 600/10/24-16 Gray 50 XBQT15D22 Blue 50 XBQT15D22BU Standard Pack Catalog Number 8 8 IDC--Multi-Conductor Terminal Blocks, Four-Wire Ground Blocks 8 8 8 Terminal Width Maximum Wire Size Connection Data in V/A/AWG EN 50 019 1 in V/A/AWG UL-cUL Ratings in V/A/AWG Color 5.2 mm 16 AWG/1.5 mm2 --/--/24-16 --/--/24-16 --/--/24-16 Green/Yellow 50 XBQT15D22PE Note 1 EU type--examination certificate number: KEMA 05ATEX2157 U (XBQT15), KEMA 05ATEX2160 U (XBQT25). 8 V7-T8-70 Volume 7--Logic Control, Operator Interface and Connectivity Solutions CA08100008E--November 2011 www.eaton.com 8.1 Terminal Blocks, Fuse Blocks and Fuse Holders IEC--XB Series IDC--Multi-Conductor Terminal Blocks, Three-Wire Ground Blocks XBQT15D12PE 8 Terminal Width Maximum Wire Size Connection Data in V/A/AWG EN 50 019 1 in V/A/AWG UL-cUL Ratings in V/A/AWG Color 5.2 mm 16 AWG/1.5 mm2 --/--/24-16 --/--/24-16 --/--/24-16 Green/Yellow 50 XBQT15D12PE 6.2 mm 14 AWG/2.5 mm2 --/--/20-14 -- --/--/20-14 Green/Yellow 50 XBQT25D12PE Standard Pack Catalog Number 8 8 8 8 Accessories 8 IDC--Multi-Conductor Terminal Blocks Description Color Number of Positions Standard Pack XBQT15D12 Catalog Number XBQT25D12 Catalog Number 8 XBQT15D22 Catalog Number 8 End cover Gray -- 10 XBACQT15D12 XBACQT25D12 XBACQT15D22 End cover segment Gray -- 10 XBASQT15 XBASQT25 XBASQT15 Partition plate -- -- 10 XBATQTD12 XBATQTD12 XBATQTD22 Plug-in bridge--for cross connections in the terminal center Red 2 10 XBAFBS25 XBAFBS26 XBAFBS25 3 10 XBAFBS35 XBAFBS36 XBAFBS35 5 10 XBAFBS55 XBAFBS56 XBAFBS55 10 10 XBAFBS105 XBAFBS106 XBAFBS105 XBAFBS505 Test adapter -- 50 10 XBAFBS505 XBAFBS506 -- 10 XBATSPAI4 XBATSPAI4 2 8 8 8 8 XBATSPAI4 2 8 2 2.3 mm diameter test plug -- -- -- XBATSMPS-_ Modular test plug -- -- 10 XBATSPS5 XBATSPS6 XBATSPS5 Blank marker strip center and external marking White -- 10 XBMZBF5 3 XBMZBF6 3 XBMZBF5 3 8 Blank marker strip center labeling (strip of 10) White -- 10 XBMZB5 3 XBMZB6 3 XBMZB5 3 8 XBATSMPS-_ XBATSMPS-_ 8 8 IDC--Multi-Conductor Terminal/Ground Blocks Standard Pack XBQT15D12PE Catalog Number XBQT25D12PE Catalog Number XBQT15D22PE Catalog Number Description Color Number of Positions End cover Gray -- 10 XBACQT15D12 XBACQT25D12 XBACQT15D22 End cover segment Gray -- 10 XBASQT15 XBASQT25 XBASQT15 Partition plate -- -- 10 XBATQTD12 XBATQTD12 XBATQTD22 Plug-in bridge--for cross connections in the terminal center Red 2 10 XBAFBS25 XBAFBS26 XBAFBS25 3 10 XBAFBS35 XBAFBS36 XBAFBS35 5 10 XBAFBS55 XBAFBS56 XBAFBS55 10 10 XBAFBS105 XBAFBS106 XBAFBS105 50 10 XBAFBS505 XBAFBS506 XBAFBS505 Test adapter -- -- 10 XBATSPAI4 XBATSPAI4 XBATSPAI4 2.3 mm diameter test plug -- -- -- XBATSMPS-_ 2 XBATSMPS-_ 2 XBATSMPS-_ 2 Modular test plug -- -- 10 XBATSPS5 XBATSPS6 XBATSPS5 Blank marker strip center and external marking White -- 10 XBMZBF5 3 XBMZBF6 3 XBMZBF5 3 Blank marker strip center labeling (strip of 10) White -- 10 XBMZB5 3 XBMZB6 3 XBMZB5 3 Notes 1 EU type--examination certificate number: KEMA 05ATEX2157 U (XBQT15PE), KEMA 05ATEX2160 U (XBQT25PE). 2 For ordering information, see Page V7-T8-105. 3 For information on Printed Marking Tag Options, see Page V7-T8-98. 8 8 8 8 8 8 8 8 8 8 8 8 For additional accessories, see Page V7-T8-90. 8 Volume 7--Logic Control, Operator Interface and Connectivity Solutions CA08100008E--November 2011 www.eaton.com V7-T8-71 8.1 Terminal Blocks, Fuse Blocks and Fuse Holders IEC--XB Series 8 Technical Data and Specifications 8 IDC--Multi-Conductor Terminal Blocks 8 Technical Data in Accordance with IEC 8 8 8 8 8 Description XBQT15D12 XBQT25D12 XBQT15D12PE XBQT25D12PE XBQT15D22 XBQT15D22PE Maximum load current in A/cross-section in mm2 17.5/1.5 24/2.5 -- -- 17.5/1.5 -- Rated surge voltage in kV/contamination class 8/3 8/3 8/3 8/3 8/3 8/3 Surge voltage category/insulating material group III/I III/I III/I III/I III/I III/I Connection Cross-Section Core insulation PVC/PE PVC/PE PVC/PE PVC/PE PVC/PE PVC/PE Single/multiple/fine strand in mm2 1.5 2.5 1.5 2.5 1.5 1.5 Halogen-free in mm2 1.5 2.5 1.5 2.5 1.5 1.5 Fine strand/superfine strand in AWG (mm2) 24-16 (0.25-0.34) 20-14 (--) 24-16 (0.25-0.34) 20-14 (--) 24-16 (0.25-0.34) 24-16 (0.25-0.34) 0.25-1.5 0.5-2.5 0.25-1.5 0.5-2.5 0.25-1.5 0.25-1.5 Repeated connections minimum 100 x in mm2 8 8 Dimensions Approximate Dimensions in Inches (mm) 8 IDC--Multi-Conductor Terminal Blocks 8 Catalog Number Length Cover Length Height for-- Width 35 x 7.5 in 35 x 15 in 8 XBQT15D12 0.20 (5.2) 3.01 (76.4) 0.09 (2.2) 1.55 (39.3) 1.84 (46.8) XBQT25D12 0.24 (6.2) 3.25 (82.5) 0.09 (2.2) 1.69 (42.8) 1.98 (50.3) XBQT15D12PE 0.20 (5.2) 3.01 (76.4) 0.09 (2.2) 1.55 (39.3) 1.84 (46.8) XBQT25D12PE 0.20 (5.2) 3.25 (82.5) 0.09 (2.2) 1.69 (42.8) 1.98 (50.3) XBQT15D22 0.20 (5.2) 3.70 (94.0) 0.09 (2.2) 1.55 (39.3) 1.84 (46.8) XBQT15D22PE 0.20 (5.2) 3.70 (94.0) 0.09 (2.2) 1.55 (39.3) 1.84 (46.8) 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 V7-T8-72 Volume 7--Logic Control, Operator Interface and Connectivity Solutions CA08100008E--November 2011 www.eaton.com 8.1 Terminal Blocks, Fuse Blocks and Fuse Holders IEC--XB Series Contents Double Level Description Page Single Level . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Multi-Conductor . . . . . . . . . . . . . . . . . . . . . . . . . . . Double Level Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . Technical Data and Specifications . . . . . . . . . . Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . Fuse Terminal Blocks . . . . . . . . . . . . . . . . . . . . . . . Disconnect and Component Terminal Blocks . . . . Hybrid Terminal Blocks . . . . . . . . . . . . . . . . . . . . . V7-T8-68 V7-T8-70 V7-T8-74 V7-T8-74 V7-T8-74 V7-T8-75 V7-T8-77 V7-T8-79 8 8 8 8 8 8 8 8 8 8 8 Double Level 8 Product Description The XBQTT IDC terminal block has the fastest connection time in a compact design. The space-saving front connection design offers additional space for wiring between the cable ducts. The double bridge shaft, found in each level, can accommodate individual chain bridging and step-down bridging from other terminal blocks. The XBQTT ground blocks are the same shape as the feed-through terminal blocks with the same wide range of cross-sections available. They easily snap onto the DIN rail to make a reliable mechanical and electrical contact that meets all requirements of IEC 60-947-7-2. 8 8 8 8 8 Product Selection XBQTT15 8 IDC--Double Level Terminal Blocks Terminal Width Maximum Wire Size Connection Data in V/A/AWG EN 50 019 1 in V/A/AWG UL-cUL Ratings in V/A/AWG 5.2 mm 16 AWG/1.5 mm2 800/17.5/24-16 420/15/24-16 600/10/24-16 Standard Pack Catalog Number 8 Gray 50 XBQTT15 Blue 50 XBQTT15BU 8 Color 8 8 XBQTT15PE 8 IDC--Double Level Ground Blocks Terminal Width Maximum Wire Size Connection Data in V/A/AWG EN 50 019 1 in V/A/AWG UL-cUL Ratings in V/A/AWG Color 6.2 mm 14 AWG/2.5 mm2 --/--/24-16 --/--/24-16 --/--/24-16 Green/Yellow 50 Standard Pack Catalog Number 8 XBQTT15PE 8 8 8 Note 1 EU type--examination certificate number: KEMA 05ATEX2157 U (XBQT15), KEMA 05ATEX2160 U (XBQT25). 8 8 8 Volume 7--Logic Control, Operator Interface and Connectivity Solutions CA08100008E--November 2011 www.eaton.com V7-T8-73 8.1 Terminal Blocks, Fuse Blocks and Fuse Holders IEC--XB Series 8 Accessories 8 IDC--Double Level Terminal/Ground Blocks Standard Pack XBQTT15 Catalog Number XBQTT15PE Catalog Number Description Color Number of Positions 8 End cover Gray -- 10 XBACQTT15 XBACQTT15 Partition plate -- -- 10 XBATQTT15 XBATQTT15 8 Plug-in bridge--for cross connections in the terminal center Red 2 10 XBAFBS25 XBAFBS25 3 10 XBAFBS35 XBAFBS35 8 5 10 XBAFBS55 XBAFBS55 10 10 XBAFBS105 XBAFBS105 8 20 10 XBAFBS505 XBAFBS505 8 8 8 Test adapter -- -- 10 XBATSPAI4 XBATSPAI4 2.3 mm diameter test plug -- -- -- XBATSMPS-_ 1 XBATSMPS-_ 1 Modular test plug -- -- 10 XBATSPS5 XBATSPS5 Blank marker strip White -- 10 XBMZBF5 2 XBMZBF5 2 8 8 8 Technical Data and Specifications IDC--Double Level Terminal/Ground Blocks Description XBQTT15 XBQTT15PE -- 8 Technical Data in Accordance with IEC Maximum load current in A/cross-section in mm2 17.5/1.5 8 Rated surge voltage in kV/contamination class 6/3 6/3 Surge voltage category/insulating material group III/I III/I 8 8 8 8 Connection Cross-Section Core insulation PVC/PE PVC/PE Single/multiple/fine strand in mm2 1.5 1.5 Halogen-free in mm2 1.5 1.5 Fine strand/superfine strand in AWG (mm2) 24-16 (0.25-0.34) 24-16 (0.25-0.34) 0.25-1.5 0.25-1.5 Repeated connections minimum 100 x in mm2 8 8 Dimensions Approximate Dimensions in Inches (mm) 8 IDC--Double Level Terminal/Ground Blocks 8 Catalog Number Length Cover Length Height for-- Width 35 x 7.5 in 35 x 15 in 8 XBQTT15 0.20 (5.2) 3.92 (99.6) 0.09 (2.2) 1.96 (49.9) 2.26 (57.4) XBQTT15PE 0.20 (5.2) 3.92 (99.6) 0.09 (2.2) 1.96 (49.9) 2.26 (57.4) 8 8 8 Notes 1 For ordering information, see Page V7-T8-105. 2 For information on Printed Marking Tag Options, see Page V7-T8-98. For additional accessories, see Page V7-T8-90. 8 8 8 8 V7-T8-74 Volume 7--Logic Control, Operator Interface and Connectivity Solutions CA08100008E--November 2011 www.eaton.com 8.1 Terminal Blocks, Fuse Blocks and Fuse Holders IEC--XB Series Contents Fuse Terminal Blocks Description Page Single Level . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Multi-Conductor . . . . . . . . . . . . . . . . . . . . . . . . . . . Double Level . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Fuse Terminal Blocks Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . Technical Data and Specifications . . . . . . . . . . Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . Disconnect and Component Terminal Blocks . . . . Hybrid Terminal Blocks . . . . . . . . . . . . . . . . . . . . . V7-T8-68 V7-T8-70 V7-T8-73 V7-T8-76 V7-T8-76 V7-T8-76 V7-T8-77 V7-T8-79 8 8 8 8 8 8 8 8 8 8 8 Fuse Terminal Blocks 8 Product Description The XBQT lever-type fuse terminal blocks perform two main functions. It is a carrier for a 5 x 20 mm cartridge fuse insert and can also allow for potential distribution via the double bridge shaft. This means that two potentials can be carried separately alongside each other. Versions with light indication (AC and DC voltage) are available to signal a triggered fuse. 8 8 8 8 Product Selection XBQT25FB 8 IDC--Fuse Terminal Blocks Terminal Width Maximum Wire Size 8 Connection Data in V/A/AWG UL-cUL Ratings in V/A/AWG Color Standard Pack Catalog Number 1/6.3/20-14 300/15/20-14 Black 50 XBQT25FBE 300/15/20-14 Black 50 XBQT25FBEL24 8 300/15/20-14 Black 50 XBQT25FBEL60 8 300/15/20-14 Black 50 XBQT25FBEL250 8 8 IDC Fuse Terminal Blocks 6.2 mm 14 AWG/2.5 mm2 IDC Fuse Terminal Blocks with LED 12-30V, 1-2.5 mA 6.2 mm 14 AWG/2.5 mm2 1/6.3/20-14 IDC Fuse Terminal Blocks with LED 30-60V, 0.8-2.0 mA 6.2 mm 14 AWG/2.5 mm2 1/6.3/20-14 IDC Fuse Terminal Blocks with LED 110-250V, 0.5-2.5 mA 6.2 mm 14 AWG/2.5 mm2 1/6.3/20-14 8 8 Note 1 As disconnect terminal block, 400V; as fuse terminal blocks 250V. 8 8 8 8 8 8 Volume 7--Logic Control, Operator Interface and Connectivity Solutions CA08100008E--November 2011 www.eaton.com V7-T8-75 8.1 Terminal Blocks, Fuse Blocks and Fuse Holders IEC--XB Series 8 Accessories 8 IDC--Fuse Terminal Blocks Standard Pack XBQT25FBE Catalog Number XBACQT25D12 Description Color Number of Positions 8 End cover Gray -- 10 Partition plate -- -- 10 XBATQTD12 8 Plug-in bridge--for cross connections in the terminal center Red 2 10 XBAFBS26 3 10 XBAFBS36 5 10 XBAFBS56 10 10 XBAFBS106 XBATSPAI4 8 8 8 Test adapter -- -- 10 8 2.3 mm diameter test plug -- -- -- XBATSMPS-_ 1 Modular test plug -- -- 10 XBATSPS5 8 Blank marker strip center and external marking White -- 10 XBMZBF6 2 Blank marker strip lever labeling White -- 10 XBMZB5 2 Blank marker strip center labeling (strip of 10) White -- 10 XBMZB6 2 8 8 8 Technical Data and Specifications 8 IDC--Fuse Terminal Blocks 8 Technical Data in Accordance with IEC Maximum load current in A/cross-section in mm2 6.3/2.5 8 Rated surge voltage in kV/contamination class 4/3 Surge voltage category/insulating material group III/I 8 Description XBQT25FBE Connection Cross-Section 8 Core insulation PVC/PE Single/multiple/fine strand in mm2 2.5 8 Halogen-free in mm2 2.5 Fine strand/superfine strand in AWG (mm2) 24-14 (--) 8 8 Repeated connections minimum 100 x in mm2 0.5-2.5 Dimensions 8 Approximate Dimensions in Inches (mm) 8 IDC--Fuse Terminal Blocks 8 Catalog Number Length Cover Length Height for-- Width 35 x 7.5 in 35 x 15 in 8 XBQT25FBE 0.24 (6.2) 3.25 (82.5) 0.09 (2.2) 1.69 (42.8) 1.98 (50.3) 8 8 Notes 1 For ordering information, see Page V7-T8-105. 2 For information on Printed Marking Tag Options, see Page V7-T8-98. For additional accessories, see Page V7-T8-90. 8 8 8 8 V7-T8-76 Volume 7--Logic Control, Operator Interface and Connectivity Solutions CA08100008E--November 2011 www.eaton.com 8.1 Terminal Blocks, Fuse Blocks and Fuse Holders IEC--XB Series Contents Disconnect and Component Terminal Blocks Description Page Single Level . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Multi-Conductor . . . . . . . . . . . . . . . . . . . . . . . . . . . Double Level . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Fuse Terminal Blocks . . . . . . . . . . . . . . . . . . . . . . . Disconnect and Component Terminal Blocks Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . Technical Data and Specifications . . . . . . . . . . Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . Hybrid Terminal Blocks . . . . . . . . . . . . . . . . . . . . . V7-T8-68 V7-T8-70 V7-T8-73 V7-T8-75 V7-T8-78 V7-T8-78 V7-T8-78 V7-T8-79 8 8 8 8 8 8 8 8 8 8 8 Disconnect and Component Terminal Blocks 8 Product Description The XB Series includes application specific terminal blocks like disconnect blocks. The knife disconnect terminal blocks (XBQT15MT) has a fitted knife. The XBQT15TG can accommodate component plugs for resistors or capacitors and fuse plugs for 5 x 20 mm fuses with or without a light indicator for signaling a triggered fuse. Both terminal blocks have three bridge shafts--two in the standard positions and one on the other side of the disconnect point. 8 8 8 8 Product Selection XBQT15MT Knife Disconnect 8 IDC--Disconnect and Component Terminal Blocks Terminal Width Maximum Wire Size UL-cUL Ratings for Disconnect with Test Sockets in V/A/AWG Color Standard Pack Catalog Number 8 Connection Data in V/A/AWG UL-cUL Ratings in V/A/AWG UL-cUL Ratings for Disconnect in V/A/AWG 400/16/24-16 600/10/24-16 -- -- Gray 50 XBQT15MT 8 8 Knife Disconnect 5.2 mm 16 AWG/1.5 mm2 Component Disconnect 8 5.2 mm 16 AWG/1.5 mm2 400/16/24-16 600/10/24-16 -- -- Gray 50 XBQT15TG 6.2 mm 14 AWG/2.5 mm2 400/16/20-14 300/10/20-14 -- -- Gray 50 XBQT25TG 8 10 AWG/4 mm2 500/16/26-10 -- 600/16/26-10 300/16/26-10 Gray 10 XBPCO 8 10 AWG/4 mm2 500/16/26-10 -- 600/16/26-10 300/16/26-10 Black 10 XBPFU 8 600/16/26-10 300/16/26-10 Black 10 XBPFUL24 600/16/26-10 300/16/26-10 Black 10 XBPFUL250 Component Plug 6.2 mm Fuse Plug 6.2 mm Fuse Plug with Light Indicator for 12-30V, 1-2.5 mA 6.2 mm 10 AWG/4 mm2 500/16/26-10 -- 8 Fuse Plug with Light Indicator for 110-250V, 0.5-2.5 mA 6.2 mm 10 AWG/4 mm2 500/16/26-10 -- 8 8 8 8 8 Volume 7--Logic Control, Operator Interface and Connectivity Solutions CA08100008E--November 2011 www.eaton.com V7-T8-77 8.1 Terminal Blocks, Fuse Blocks and Fuse Holders IEC--XB Series 8 Accessories 8 IDC--Disconnect and Component Terminal Blocks 8 Number of Positions Standard Pack XBQT15MT Catalog Number XBQT15TG Catalog Number XBQT25TG Catalog Number XBACQT25D12 Description Color 8 End cover Gray -- 10 XBACQT15D12 XBACQT15D12 End cover segment Gray -- 10 XBASQT15 XBASQT15 XBASQT25 8 Partition plate -- -- 10 XBATQTD12 XBATQTD12 XBATQTD12 Plug-in bridge Red 2 10 XBAFBS25 XBAFBS25 XBAFBS26 8 3 10 XBAFBS35 XBAFBS35 XBAFBS36 5 10 XBAFBS55 XBAFBS55 XBAFBS56 8 10 10 XBAFBS105 XBAFBS105 XBAFBS106 8 8 8 Test adapter -- -- 10 XBATSPAI4 XBATSPAI4 XBATSPAI4 2.3 mm diameter test plug -- -- -- XBATSMPS-_ 1 XBATSMPS-_ 1 XBATSMPS-_ 1 Modular test plug -- -- 10 XBATSPS5 XBATSPS5 XBATSPS5 Blank marker strip center and external marking White -- 10 XBMZBF5 2 XBMZBF5 2 XBMZBF6 2 Blank marker strip center labeling (strip of 10) White -- 10 XBMZB5 2 XBMZB5 2 XBMZB6 2 8 8 Technical Data and Specifications 8 IDC--Disconnect and Component Terminal Blocks 8 Technical Data in Accordance with IEC 8 8 Description XBQT15MT XBQT15TG XBQT25TG Maximum load current in A/cross-section in mm2 16/1.5 16/1.5 16/2.5 Rated surge voltage in kV/contamination class 6/3 6/3 6/3 Surge voltage category/insulating material group III/I III/I III/I Connection Cross-Section 8 Core insulation PVC/PE PVC/PE PVC/PE Single/multiple/fine strand in mm2 1.5 1.5 2.5 8 Halogen-free in mm2 1.5 1.5 2.5 Fine strand/superfine strand in AWG (mm2) 24-16 (0.25-0.34) 24-16 (0.25-0.34) 20-14 (--) 0.25-1.5 0.25-1.5 0.5-2.5 8 8 Repeated connections minimum 100 x in mm2 Dimensions 8 Approximate Dimensions in Inches (mm) 8 IDC--Disconnect and Component Terminal Blocks 8 Catalog Number Length Cover Length Height for-- Width 35 x 7.5 in 35 x 15 in 8 XBQT15MT 0.20 (5.2) 3.01 (76.4) 0.09 (2.2) 1.55 (39.3) 1.84 (46.8) XBQT15TG 0.20 (5.2) 3.01 (76.4) 0.09 (2.2) 1.55 (39.3) 1.84 (46.8) 8 XBQT25TG 0.24 (6.2) 3.25 (82.5) 0.09 (2.2) 1.69 (42.8) 1.98 (50.3) 8 Notes 1 For ordering information, see Page V7-T8-105. 2 For information on Printed Marking Tag Options, see Page V7-T8-98. 8 For additional accessories, see Page V7-T8-90. 8 8 8 V7-T8-78 Volume 7--Logic Control, Operator Interface and Connectivity Solutions CA08100008E--November 2011 www.eaton.com 8.1 Terminal Blocks, Fuse Blocks and Fuse Holders IEC--XB Series Contents Hybrid Terminal Blocks Description Page Single Level . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Multi-Conductor . . . . . . . . . . . . . . . . . . . . . . . . . . . Double Level . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Fuse Terminal Blocks . . . . . . . . . . . . . . . . . . . . . . . Disconnect and Component Terminal Blocks . . . . Hybrid Terminal Blocks Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . Technical Data and Specifications . . . . . . . . . . Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . V7-T8-68 V7-T8-70 V7-T8-73 V7-T8-75 V7-T8-77 V7-T8-80 V7-T8-81 V7-T8-81 8 8 8 8 8 8 8 8 8 8 8 Hybrid Terminal Blocks 8 Product Description The XBQT hybrid terminal blocks offer the best of both worlds. One side offers the time-saving advantage of our insulation displacement connection technology, while the other side offers a universal screw connection. Use the IDC side on the internal (factory) control cabinet side and the screw connection on the end customer (field) side. Ground terminal blocks of the same shape are also available 8 8 8 Product Selection XBQU25 8 IDC--Hybrid Terminal Blocks, Single Level Terminal Width Maximum Wire Size IEC Screw Connection in V/A/AWG 5.2 mm 12 AWG/2.5 mm2 800/17.5/26-12 800/17.5/24-16 600/10/26-12 600/10/24-16 6.2 mm 10 AWG/4 mm2 800/24/26-10 800/24/20-14 600/15/26-10 600/15/20-14 IEC IDC Connection in V/A/AWG UL-cUL Screw Connection in V/A/AWG UL-cUL IDC Connection in V/A/AWG 8 Standard Pack Catalog Number 8 Gray 50 XBQU15 Gray 50 XBQU25 8 Color 8 XBQU15D12 8 IDC--Hybrid Terminal Blocks, Three-Wire Terminal Width Maximum Wire Size IEC Screw Connection in V/A/AWG IEC IDC Connection in V/A/AWG UL-cUL Screw Connection in V/A/AWG UL-cUL IDC Connection in V/A/AWG 5.2 mm 12 AWG/2.5 mm2 800/17.5/26-12 800/17.5/24-16 800/10/26-12 800/10/24-16 6.2 mm 10 AWG/4 mm2 800/24/26-10 800/24/20-14 600/15/26-10 600/15/20-14 8 Color Standard Pack Catalog Number Gray 50 XBQU15D12 Gray 50 XBQU25D12 8 8 8 XBQU25PE 8 IDC--Hybrid Terminal/Ground Blocks Terminal Width Maximum Wire Size IEC Screw Connection in V/A/AWG IEC IDC Connection in V/A/AWG UL-cUL Screw Connection in V/A/AWG UL-cUL IDC Connection in V/A/AWG Color Standard Pack Catalog Number 8 5.2 mm 12 AWG/2.5 mm2 --/--/26-12 --/--/24-16 --/--/26-12 --/--/24-16 Gray 50 XBQU15PE 6.2 mm 10 AWG/4 mm2 --/--/26-10 --/--/20-14 --/--/26-10 --/--/20-14 Gray 50 XBQU25PE 8 8 8 Volume 7--Logic Control, Operator Interface and Connectivity Solutions CA08100008E--November 2011 www.eaton.com V7-T8-79 8.1 Terminal Blocks, Fuse Blocks and Fuse Holders IEC--XB Series 8 Accessories 8 IDC--Hybrid Terminal Blocks Standard Pack XBQU15 Catalog Number XBQU25 Catalog Number XBQU15D12 Catalog Number XBQU25D12 Catalog Number XBACQU25D12 Description Color Number of Positions 8 End cover Gray -- 10 XBACQU15 XBACQU25 XBACQU15D12 End segment Gray -- 10 -- -- XBASQT15 XBASQT25 8 Partition plate -- -- 10 XBATQT25 XBATQT25 XBATQTD12 XBATQTD12 Plug-in bridge--for cross connections in the bridge shaft Red 2 10 XBAFBS25 XBAFBS26 XBAFBS25 XBAFBS26 3 10 XBAFBS35 XBAFBS36 XBAFBS35 XBAFBS36 5 10 XBAFBS55 XBAFBS56 XBAFBS55 XBAFBS56 10 10 XBAFBS105 XBAFBS106 XBAFBS105 XBAFBS106 50 10 XBAFBS505 XBAFBS506 XBAFBS505 XBAFBS506 8 8 8 8 Test adapter -- -- 10 XBATSPAI4 XBATSPAI4 XBATSPAI4 XBATSPAI4 2.3 mm diameter test plug -- -- -- XBATSMPS-_ 1 XBATSMPS-_ 1 XBATSMPS-_ 1 XBATSMPS-_ 1 8 Modular test plug -- -- 10 XBATSPS5 XBATSPS6 XBATSPS5 XBATSPS6 8 Blank marker strip center and external marking White -- 10 XBMZBF5 2 XBMZBF6 2 XBMZBF5 2 XBMZBF6 2 8 Blank marker strip center labeling (strip of 10) XBMZB5 2 XBMZB6 2 XBMZB5 2 XBMZB6 2 XBQU15PE Catalog Number XBQU25PE Catalog Number XBACQU25 8 8 8 8 8 IDC--Hybrid Terminal/Ground Blocks Description Color Number of Positions End cover Gray -- 10 XBACQU15 Partition plate -- -- 10 XBATQT25 XBATQT25 Plug-in bridge--for cross connections in the bridge shaft Red 2 10 XBAFBS25 XBAFBS26 3 10 XBAFBS35 XBAFBS36 5 10 XBAFBS55 XBAFBS56 10 10 XBAFBS105 XBAFBS106 8 Standard Pack 50 10 XBAFBS505 XBAFBS506 Test adapter -- -- 10 XBATSPAI4 XBATSPAI4 8 2.3 mm diameter test plug -- -- -- XBATSMPS-_ 1 XBATSMPS-_ 1 Modular test plug -- -- 10 XBATSPS5 XBATSPS6 8 Blank marker strip center and external marking White -- 10 XBMZBF5 2 XBMZBF6 2 8 Blank marker strip center labeling (strip of 10) XBMZB5 2 XBMZB6 2 8 Notes 1 For ordering information, see Page V7-T8-105. 2 For information on Printed Marking Tag Options, see Page V7-T8-98. 8 8 For additional accessories, see Page V7-T8-90. 8 8 8 8 8 8 8 V7-T8-80 Volume 7--Logic Control, Operator Interface and Connectivity Solutions CA08100008E--November 2011 www.eaton.com 8.1 Terminal Blocks, Fuse Blocks and Fuse Holders IEC--XB Series Technical Data and Specifications 8 Screw Connection Single Level--Through-Feed Description XBQU15 XBQU25 XBQU15PE XBQU25PE XBQU15D12 XBQU25D12 Maximum load current in A/cross-section in mm2 17.5/1.5 24/2.5 -- -- 17.5/1.5 24/2.5 Rated surge voltage in kV/contamination class 8/3 8/3 8/3 8/3 8/3 8/3 Surge voltage category/insulating material group III/I III/I III/I III/I III/I III/I 8 8 Technical Data in Accordance with IEC 8 8 Connection Cross-Section Core insulation PVC/PE PVC/PE PVC/PE PVC/PE PVC/PE PVC/PE Single/multiple/fine strand in mm2 1.5 2.5 1.5 2.5 1.5 2.5 Halogen-free in mm2 1.5 2.5 1.5 2.5 1.5 2.5 Fine strand/superfine strand in AWG (mm2) 24-16 (0.25-0.34) 20-14 (--) 24-16 (0.25-0.34) 20-14 (--) 24-16 (0.25-0.34) 20-14 (--) 0.25-1.5 0.5-2.5 0.25-1.5 0.5-2.5 0.25-1.5 0.5-2.5 8 0.25-2.5/0.25-2.5 0.25-4/0.25-4 0.25-2.5/0.25-2.5 0.25-4/0.25-4 0.25-2.5/0.25-2.5 0.25-4/0.25-4 8 Repeated connections minimum 100 x in mm2 8 8 Connection Capacity--Screw Connection Stranded with ferrule/with ferrule and plastic sleeve in mm2 8 Multi-Conductor Connection (same cross-section) Solid/stranded in mm2 0.14-1.5/0.14-1.5 0.14-1.5/0.14-1.5 0.14-1.5/0.14-1.5 Stranded with ferrules without plastic sleeve in mm2 0.25-1.5 0.25-1.5 0.25-1.5 0.25-1.5 0.25-1.5 0.25-1.5 Stranded with twin ferrule with plastic sleeve in mm2 0.5-1.5 0.5-2.5 0.5-1.5 0.5-2.5 0.5-1.5 0.5-2.5 0.14-1.5/0.14-1.5 0.14-1.5/0.14-1.5 0.14-1.5/0.14-1.5 8 8 8 Stripping length in inches (mm) 0.35 (9) 0.35 (9) 0.35 (9) 0.35 (9) 0.35 (9) 0.35 (9) Thread M3 M3 M3 M3 M3 M3 Torque in in-lb (Nm) 5.3-7.1 (0.6-0.8) 5.3-7.1 (0.6-0.8) 5.3-7.1 (0.6-0.8) 5.3-7.1 (0.6-0.8) 5.3-7.1 (0.6-0.8) 5.3-7.1 (0.6-0.8) 8 8 Dimensions Approximate Dimensions in Inches (mm) 8 Screw Connection Single Level--Through-Feed 8 Catalog Number Width Length Cover Width Height for-- 35 x 7.5 in 35 x 15 in XBQU15 0.20 (5.2) 2.31 (58.8) 0.09 (2.2) 1.69 (42.8) 1.98 (50.3) XBQU25 0.24 (6.2) 2.46 (62.6) 0.09 (2.2) 1.69 (42.8) 1.98 (50.3) XBQU15PE 0.20 (5.2) 2.31 (58.8) 0.09 (2.2) 1.69 (42.8) 1.98 (50.3) XBQU25PE 0.24 (6.2) 2.46 (62.6) 0.09 (2.2) 1.69 (42.8) 1.98 (50.3) XBQU15D12 0.20 (5.2) 3.01 (76.4) 0.09 (2.2) 1.69 (42.8) 1.98 (50.3) XBQU25D12 0.24 (6.2) 3.25 (82.5) 0.09 (2.2) 1.69 (42.8) 1.98 (50.3) 8 8 8 8 8 8 8 8 8 8 8 8 8 Volume 7--Logic Control, Operator Interface and Connectivity Solutions CA08100008E--November 2011 www.eaton.com V7-T8-81 8.1 8 Terminal Blocks, Fuse Blocks and Fuse Holders IEC--XB Series Contents Miniature Circuit Breakers Description 8 Miniature Circuit Breakers Circuit Breakers. . . . . . . . . . . . . . . . . . . . . . . . . Flat-Type Fuse Terminal Blocks . . . . . . . . . . . . . Spring Cage Fuse Terminal Blocks . . . . . . . . . . 8 8 8 8 8 8 8 8 8 Miniature Circuit Breakers Overview 8 Product Description 8 8 8 8 8 8 The new XB Series thermal miniature circuit breaker offers convenient overload protection. This space-saving single-pole circuit breaker, available up to 10 amps, can be inserted into a screw connection fuse terminal block, XBUK6FSI, or a spring cage fuse terminal block, XBPT4FSI, which is available with or without light indication. The XBATCP combines the Standards and Certifications reclosing capability of a circuit breaker with the overload protection of a fuse. The integrated switching function makes it possible to switch the circuit breaker back on immediately, guaranteeing system availability. The device can also be used for switching purposes, as an ON/OFF switch. The Plug-in design allows for quick and efficient replacement. UL and cUL recognized UL 1077--File No. E301915 CE approved 8 8 8 8 8 8 8 8 8 8 8 8 V7-T8-82 Volume 7--Logic Control, Operator Interface and Connectivity Solutions CA08100008E--November 2011 www.eaton.com Page V7-T8-83 V7-T8-86 V7-T8-88 Terminal Blocks, Fuse Blocks and Fuse Holders IEC--XB Series 8.1 Contents Circuit Breakers Description Circuit Breakers Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . Technical Data and Specifications . . . . . . . . . . Time/Current Curve . . . . . . . . . . . . . . . . . . . . . Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . Flat-Type Fuse Terminal Blocks . . . . . . . . . . . . . . . Spring Cage Fuse Terminal Blocks . . . . . . . . . . . . . Page 8 8 V7-T8-84 V7-T8-84 V7-T8-85 V7-T8-85 V7-T8-86 V7-T8-88 8 8 8 8 8 8 8 8 8 Circuit Breakers 8 Product Description The thermal miniature circuit breaker can be switched back on again, has a compact design, and is available in 10 finely graded steps for nominal currents from 0.1 to 10A. 8 8 8 Product Selection XBAT 8 Thermal Miniature Circuit Breaker Connection Data in Vac/Vdc 250/65 Nominal Current Color Standard Pack Catalog Number 8 8 0.1A Black 20 XBATCPT 0.25A Black 20 XBATCPQ 0.5A Black 20 XBATCPH 1.0A Black 20 XBATCP1 2.0A Black 20 XBATCP2 3.0A Black 20 XBATCP3 4.0A Black 20 XBATCP4 6.0A Black 20 XBATCP6 8.0A Black 20 XBATCP8 10.0A Black 20 XBATCP10 8 8 8 8 8 8 8 8 8 8 8 8 Volume 7--Logic Control, Operator Interface and Connectivity Solutions CA08100008E--November 2011 www.eaton.com V7-T8-83 8.1 Terminal Blocks, Fuse Blocks and Fuse Holders IEC--XB Series 8 Accessories 8 Thermal Miniature Circuit Breaker 8 8 Description Color Number of Positions Standard Pack XBAT Catalog Number Blank marker strip White -- 10 XBMZBF5 1 Flat type terminal blocks -- -- -- XBUK6FSI 8 XBUK6FSIL12 8 XBPT4FSI 8 XBPT4FSIL24 8 8 8 8 8 8 8 8 8 XBUK6FSIL24 XBPT4FSIL12 Technical Data and Specifications Thermal Miniature Circuit Breaker Description XBAT Technical Data in Accordance with IEC Nominal voltage in Vac/Vdc 250/65 Nominal current in A 0.25-10 Ambient temperature -4 to 140F (-20 to 60C) Maximum Power Dissipation Rated surge voltage in kV/contamination class 2.5/2 Surge voltage category/insulating material group III/I Switching Capacity Cycles with 1 x IN (low-induction) 6000 Cycles with 1 x IN (induction) 3000 Cycles with 2 x IN (induction) 500 8 Switching Capacity I CN 8 Switching capacity (UL 1077) 250 Vac/65 Vdc 6 x IN/8 x IN For nominal currents of 0.25-4A/6-10A 2000/200 8 8 Nominal Currents and Internal Resistances Nominal Current (A) Internal Resistance (3/4) 0.25 14 0.5 3.4 1.0 0.9 2.0 0.25 3.0 0.11 4.0 0.07 8 6.0 <0.05 8.0 <0.05 8 10.0 <0.05 8 Note 1 For information on Printed Marking Tag Options, see Page V7-T8-98. 8 8 8 8 8 8 8 V7-T8-84 Volume 7--Logic Control, Operator Interface and Connectivity Solutions CA08100008E--November 2011 www.eaton.com Terminal Blocks, Fuse Blocks and Fuse Holders IEC--XB Series 8.1 Time/Current Curve 8 Total Switch-Off Period for Nominal Current, 73.4F (23C) 0.25A - 4A 6A- 10A 8 Temperature Factor 1000 Response Time in Seconds 8 Note: When mounted in rows, the nominal current of the devices can only be transmitted at 80% or must be correspondingly over-dimensioned. 10,000 100 Ambient Temperature Temperature Factor -4F (-20C) 0.76 14F (-10C) 0.84 32F (0C) 0.91 73.4F (23C) 1.00 104F (40C) 1.08 122F (50C) 1.16 140F (60C) 1.24 8 8 8 8 8 8 8 10 8 8 8 1 8 8 0.1 0.8 1 2 3 4 5 6 Multiples of IN 8 10 8 20 8 Dimensions 8 Approximate Dimensions in Inches (mm) XBUK6FSI with XBAT XBPT4FSI with XBAT 2.52 (64) 0.96 (24.4) 8 3.41 (86.5) 0.32 (8.2) 0.96 (24.4) 0.32 (8.2) 8 8 8 1.75 (44.5) 8 3.39 (86.2) 8 8 1.93 (49) 2.03 (51.5) 1.73 (44) 8 1.72 (43.7) 8 8 8 8 Volume 7--Logic Control, Operator Interface and Connectivity Solutions CA08100008E--November 2011 www.eaton.com V7-T8-85 8.1 8 Terminal Blocks, Fuse Blocks and Fuse Holders IEC--XB Series Contents Flat-Type Fuse Terminal Blocks Description 8 Page Circuit Breakers . . . . . . . . . . . . . . . . . . . . . . . . . . . Flat-Type Fuse Terminal Blocks Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . Technical Data and Specifications . . . . . . . . . . Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . Spring Cage Fuse Terminal Blocks . . . . . . . . . . . . 8 8 8 V7-T8-83 V7-T8-86 V7-T8-87 V7-T8-87 V7-T8-88 8 8 8 8 8 8 Flat-Type Fuse Terminal Blocks 8 Product Description 8 8 The fuse terminal blocks can be used as a basic terminal blocks for the XBAT overload miniature circuit breaker, see Page V7-T8-83. 8 8 Product Selection 8 XBUK6FSI Screw Connection Flat-Type Fuse Terminal Blocks Terminal Width 8 Maximum Wire Size Connection Data in V/A/AWG UL-cUL Ratings in V/A/AWG Color Standard Pack Catalog Number 250/--/24-8 300/30/26-8 Black 50 XBUK6FSI 300/30/26-8 Black 50 XBUK6FSIL12 300/30/26-8 Black 50 XBUK6FSIL24 Flat-Type Fuse Terminal Block 8 8.2 mm 8 AWG/6 mm2 Flat-Type Fuse Terminal Block with LED, Red 12 Vdc, 2.0 mA 8 8.2 mm 8 AWG/6 mm2 250/--/24-8 Flat-Type Fuse Terminal Block with LED, Red 24 Vdc, 2.0 mA 8 8.2 mm 8 AWG/6 mm2 250/--/24-8 8 8 Accessories 8 Flat-Type Fuse Terminal Blocks 8 8 8 Description Color Number of Positions Blank marker strip White -- Standard Pack XBUK6FSI Catalog Number XBUK6FSIL_ Catalog Number 10 XBMZB8 1 XBMZB8 1 Note 1 For information on Printed Marking Tag Options, see Page V7-T8-98. 8 8 8 V7-T8-86 Volume 7--Logic Control, Operator Interface and Connectivity Solutions CA08100008E--November 2011 www.eaton.com Terminal Blocks, Fuse Blocks and Fuse Holders IEC--XB Series 8.1 Technical Data and Specifications 8 Flat-Type Fuse Terminal Blocks Description 8 XBUK6FSI XBUK6FSIL_ Fuse type ISO C C Maximum current with single arrangement in A 30 30 8 Rated surge voltage in kV/contamination class 4/3 4/3 8 Surge voltage category/insulating material group III/I III/I 8 Stranded with ferrule with plastic sleeve in mm2 0.25-4 0.25-4 8 Stranded with ferrule without plastic sleeve in mm2 0.25-6 0.25-6 Stranded with twin ferrule with plastic sleeve in mm2 -- -- Solid/stranded in mm2 0.2-2.5/0.2-2.5 0.2-2.5/0.2-2.5 Stranded with ferrules without plastic sleeve in mm2 0.25-2.5 0.25-2.5 Stranded with twin ferrule with plastic sleeve in mm2 0.5-4.0 0.5-4.0 Stripping length in inches (mm) 0.39 (10) 0.39 (10) Thread M4 M4 Torque in in-lb (Nm) 13.3-14.2 (1.5-1.6) 13.3-14.2 (1.5-1.6) 8 Technical Data in Accordance with IEC Maximum Power Dissipation Connection Capacity 8 Multi-Conductor Connection (same cross-section) 8 8 8 8 8 8 Dimensions Approximate Dimensions in Inches (mm) 8 Flat-Type Fuse Terminal Blocks 8 Height for-- Catalog Number Width Length 32 in 35 x 7.5 in 35 x 15 in XBUK6FSI 0.32 (8.2) 2.91 (74.0) 2.24 (57.0) 2.05 (52.0) 2.34 (59.5) XBUK6FSIL12 0.32 (8.2) 2.91 (74.0) 2.24 (57.0) 2.05 (52.0) 2.34 (59.5) XBUK6FSIL24 0.32 (8.2) 2.91 (74.0) 2.24 (57.0) 2.05 (52.0) 2.34 (59.5) 8 8 8 8 8 8 8 8 8 8 8 8 8 8 Volume 7--Logic Control, Operator Interface and Connectivity Solutions CA08100008E--November 2011 www.eaton.com V7-T8-87 8.1 8 Terminal Blocks, Fuse Blocks and Fuse Holders IEC--XB Series Contents Spring Cage Fuse Terminal Blocks Description 8 Page Circuit Breakers . . . . . . . . . . . . . . . . . . . . . . . . . . . Flat-Type Fuse Terminal Blocks . . . . . . . . . . . . . . . Spring Cage Fuse Terminal Blocks Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . Technical Data and Specifications . . . . . . . . . . Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 8 8 V7-T8-83 V7-T8-86 V7-T8-88 V7-T8-89 V7-T8-89 8 8 8 8 8 8 Spring Cage Fuse Terminal Blocks 8 Product Description 8 8 Flat-type fuses or the XBAT miniature circuit breaker (see Page V7-T8-83) can be used as the fuse element in these XBPT Spring Cage Fuse Terminal Blocks. Terminal blocks with a light indicator are available for quick error diagnosis. 8 8 Product Selection 8 XBPT4FSI Spring Cage Fuse Terminal Blocks Terminal Width 8 Maximum Wire Size Connection Data in V/A/AWG UL-cUL Ratings in V/A/AWG Color Standard Pack Catalog Number 400/30/28-10 300/30/24-10 Black 50 XBPT4FSI Black 50 XBPT4FSIL12 Black 50 XBPT4FSIL24 Spring Cage Fuse Terminal Block 8 8.2 mm 10 AWG/4 mm2 Spring Cage Fuse Terminal Block with LED, Red 12 Vdc, 2.0 mA 8 8.2 mm 10 AWG/4 mm2 400/30/28-10 300/30/24-10 Spring Cage Fuse Terminal Block with LED, Red 24 Vdc, 2.0 mA 8 8.2 mm 10 AWG/4 mm2 400/30/28-10 300/30/24-10 8 8 8 8 8 8 8 8 Accessories Flat-Type Fuse Terminal Blocks Description Color Number of Positions Standard Pack XBPT4FSI Catalog Number XBPT4FSIL_ Catalog Number Test adapter -- -- 10 XBATSPAI4 XBATSPAI4 2.3 mm diameter test plug -- -- -- XBATSMPS-_ 1 XBATSMPS-_ 1 Modular test plug -- -- 10 XBATSPS8 XBATSPS8 Blank marker strip center and external marking White -- 10 XBMZBF8 2 XBMZBF8 2 Blank marker strip center labeling (strip of 10) White -- 10 XBMZB8 2 XBMZB8 2 Notes 1 For ordering information, see Page V7-T8-105. 2 For information on Printed Marking Tag Options, see Page V7-T8-98. 8 V7-T8-88 Volume 7--Logic Control, Operator Interface and Connectivity Solutions CA08100008E--November 2011 www.eaton.com Terminal Blocks, Fuse Blocks and Fuse Holders IEC--XB Series 8.1 Technical Data and Specifications 8 Flat-Type Fuse Terminal Blocks Description 8 XBPT4FSI XBPT4FSIL_ Fuse type ISO C C Maximum current with single arrangement in A 30 30 8 Rated surge voltage in kV/contamination class 6/3 6/3 8 Surge voltage category/insulating material group III/I III/I 8 Stranded with ferrule with plastic sleeve in mm2 0.25-4 0.25-4 8 Stranded with ferrule without plastic sleeve in mm2 0.25-4 0.25-4 Stranded with twin ferrule with plastic sleeve in mm2 0.5 0.5 0.39 (10) 0.39 (10) 8 Technical Data in Accordance with IEC Maximum Power Dissipation Connection Capacity Stripping length in inches (mm) 8 8 8 Dimensions Approximate Dimensions in Inches (mm) 8 Flat-Type Fuse Terminal Blocks 8 Height for-- Catalog Number Width Length 35 x 7.5 in 35 x 15 in XBPT4FSI 0.32 (8.2) 3.41 (86.5) 1.71 (43.5) 2.01 (51.0) XBPT4FSIL12 0.32 (8.2) 3.41 (86.5) 1.71 (43.5) 2.01 (51.0) XBPT4FSIL24 0.32 (8.2) 3.41 (86.5) 1.71 (43.5) 2.01 (51.0) 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 Volume 7--Logic Control, Operator Interface and Connectivity Solutions CA08100008E--November 2011 www.eaton.com V7-T8-89 8.1 8 Terminal Blocks, Fuse Blocks and Fuse Holders IEC--XB Series Contents XB Series Accessories Description 8 Page XB Series Accessories End Stops . . . . . . . . . . . . . . . . . . . . . . . . . . . . . DIN Rails . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Angled Mounting Brackets . . . . . . . . . . . . . . . . Ferrules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Hand Tools . . . . . . . . . . . . . . . . . . . . . . . . . . . . Marking Accessories . . . . . . . . . . . . . . . . . . . . Testing Accessories . . . . . . . . . . . . . . . . . . . . . Separating Plates, Covers and Bridges . . . . . . 8 8 8 8 V7-T8-91 V7-T8-92 V7-T8-93 V7-T8-94 V7-T8-97 V7-T8-98 V7-T8-105 V7-T8-105 8 8 8 8 8 XB Series Accessories Overview 8 End Stops Angled Mounting Brackets Hand Tools Marking Accessories The end stop provides an anchor point at each end of the rail assembly by attaching directly to the DIN rail. A wide range of end stop options are available, including those that mount with one or multiple screws and those that do not require screws for mounting. End stops also have a location for marking material to be placed. Angled mounting brackets are used to mount DIN rail at a more accessible angle for wiring and troubleshooting. Eaton offers an array of hand tools to make it easier to work with our terminal blocks. The XBTCUTSTP tool is recommended for cutting and stripping PVC insulated wires. The ergonomically shaped crimping pliers, XBTCRMP66, result in fatigue-free work by spreading the manual force equally between the six jaws. The XBTDVR screwdrivers have a rotating cap that prevents user discomfort even at high torques and allows rapid rotation. The ergonomically shaped handle further aids the user's comfort. The blade is made from CVM steel, hardened and chrome-plated. The marking system provides logical and clear identification of the modular terminal blocks and interface modules. The blank marker strip is designed for marking terminal blocks, equipment and smaller modules with marker grooves. The marker strip is available in all common pitches in printed and unprinted versions. 8 8 8 8 8 8 8 8 8 8 8 8 8 8 DIN Rail Eaton offers ways for timesaving and secure mounting of components needed for electrical connections. DIN rail provides the basis for the inner design of the control cabinet and ensures a firm hold of the rail-mountable components. Eaton offers a wide range of standard DIN rails sizes and materials, solid or slotted. Or, contact us about custom lengths of pre-cut rail or ordering predrilled rail. The DIN rails are designed in accordance with the European standard EN 60715. Ferrules Ferrules are available with or without an insulating sleeve. The plastic insulating sleeve simplifies the fitting of the conductor and the color indicates the size of the cross-section. The closer the connections are, the more reliable the insulation is and the less likely the wires are to splice. Twin ferrules are also available allowing two wires to be easily compressed in one ferrule. Chain bridging, frequently used in industry, becomes easier with twin ferrules. Testing Accessories The range of test accessories available includes different test plugs, so that an optimum solution can be realized for every application. In addition to pre-assembled test plugs, plugs are also available that can be configured individually to form test adapters. 8 8 8 8 V7-T8-90 Volume 7--Logic Control, Operator Interface and Connectivity Solutions CA08100008E--November 2011 www.eaton.com 8.1 Terminal Blocks, Fuse Blocks and Fuse Holders IEC--XB Series End Stops 8 Product Selection XBAES35AL Universal End Stop (15 mm) Aluminum End Standard Pack Catalog Number Standard Pack Catalog Number Standard Pack Catalog Number 8 50 XBAES15N 50 XBAES15C 10 XBAES35AL 8 Snap-On End Stop (35 mm) Universal End Stop (35 mm) Standard Pack Catalog Number Standard Pack Catalog Number 50 XBAES35N 50 XBAES35T 50 XBAES35C XBAES35C XBAES35T 8 Snap-On End Stop (15 mm) Snap-on end stops for 35 mm and 15 mm DIN rails can be fitted with blank marker strips and adjustable terminal strip markers, parking facility for bridges and testing accessories. Snaps on, for end support of 50-240 mm terminal blocks, labeling with XBMZB10. 8 8 8 Screwed on, labeling with blank marker strips and terminal strip markers. 8 Cross-Reference of Terminal Blocks Marking, End Stops Catalog Number XBMKLM2 XBMGLMA XBMUBE XBAES35N X -- -- XBAES35T -- X X 8 8 8 8 Dimensions 8 Approximate Dimensions in Inches (mm) Snap-On End Stop XBAES35N XBAES15N 1.91 (48.5) 1.38 (35) 0.98 (24.8) 0.87 (22) Aluminum End Stop 8 XBAES35AL 8 2.32 (59) 0.20 (5.2) 8 8 1.73 (44) 0.89 (22.6) 8 8 0.20 (5) 8 0.39 (10) 8 8 Universal End Stop XBAES35T 8 XBAES15C XBAES35C 0.83 (21.2) 1.91 (48.6) 1.99 (50.5) 8 8 0.71 (18) 1.39 (35.3) 1.29 (32.8) 8 0.24 (6.1) 8 0.37 (9.5) 8 0.37 (9.5) 8 8 Volume 7--Logic Control, Operator Interface and Connectivity Solutions CA08100008E--November 2011 www.eaton.com V7-T8-91 8.1 8 8 Terminal Blocks, Fuse Blocks and Fuse Holders IEC--XB Series DIN Rails Product Selection 8 8 Perforated and unperforated DIN rails in accordance with E 60715. 35 x 7.5 mm x 2m 15 x 5.5 mm x 2m Standard Pack Standard Pack Catalog Number Features Slotted 25 XBANS15P 8 8 8 High dimensional accuracy Restricted tolerances Double surface tempering, galvanized and chromated All 2m in length Customization available 8 25 Catalog Number XBANS3575P Solid 25 XBANS3575U 35 x 15 mm x 2m Standard Pack 25 8 25 Standard Pack Catalog Number 35/7.5/2m Catalog Number 25 XBANS3575PL 35/58/2m Slotted 8 Aluminum DIN Rails (Perforated) XBANS3515P 6 XBANS35PL Solid XBANS3515U 8 8 8 Dimensions 8 Approximate Dimensions in Inches (mm) 8 35 x 7.5 mm DIN Rail 8 8 35 x 15 mm DIN Rail 0.04 (1) 0.30 (7.5) 1.06 (27) 8 0.06 (1.5) 1.38 (35) 0.03 (0.8) Rad. 0.24 (6.2) 0.03 (0.8) Rad. 0.59 (15) 8 0.04 (1) 15 0.05 (1.25) Rad. 0.59 (15) 0.22 (5.5) 0.41 (10.5) 0.05 (1.25) Rad. 0.01 (0.2) Rad. 0.02 (0.5) Rad. XBANS35PL Raised Rail 0.08 (2) 2.28 (58) 1.89 (48) 1.02 (26) 0.48 (12.2) 0.59 (15) 0.59 (15) 0.98 (25) 0.79 (20) 1.02 (26) 5.00 (127) 0.98 (25) 8 8 8 8 8 8 8 8 V7-T8-92 0.95 (24) 1.38 (35) 0.17 (4.2) 0.24 (6.2) 8 8 0.03 (0.8) 1.38 (35) 1.06 (27) 8 15 x 5.5 mm x 2m DIN Rail Volume 7--Logic Control, Operator Interface and Connectivity Solutions CA08100008E--November 2011 www.eaton.com Terminal Blocks, Fuse Blocks and Fuse Holders IEC--XB Series 8.1 Angled Mounting Brackets 8 Product Selection The angled brackets enable the DIN rail to be mounted with a spacing or at an angle of 30. Features For mounting DIN rail at 30 angle For use with M6 screw Chromated steel Provides better visibility 8 Angled Mounting Bracket Standard Pack 8 Catalog Number Height Inches (mm) 1.39 (35.4) 8 10 8 XBANBGS Height Inches (mm) 1.81 (46) 10 8 XBANBGSH 8 8 8 Dimensions 8 Approximate Dimensions in Inches (mm) 8 XBANBGS 8 XBANBGSH 0.61 (15.4) 0.65 (16.5) 3.43 (87) M6 Screw 2.54 (64.5) 8 3.31 (84) M6 Screw 8 2.44 (62) 8 30 30 0.08 (2) 1.39 (35.4) 8 0.54 (13.7) 0.55 (14) 0.79 (20) 0.28 (7) Dia. 0.08 (2) 1.81 (46) 0.79 (20) 8 0.28 (7) Dia. 8 8 8 8 8 8 8 8 8 8 8 8 8 Volume 7--Logic Control, Operator Interface and Connectivity Solutions CA08100008E--November 2011 www.eaton.com V7-T8-93 8.1 8 8 Terminal Blocks, Fuse Blocks and Fuse Holders IEC--XB Series Ferrules Product Selection 8 Ferrules are offered in two basic designs--an insulated style available in models for wire sizes 20 through 4 AWG and a non-insulated type available in models for wire sizes 22 through 6 AWG. 8 Insulated 8 8 8 8 Note: UL Ratings do not typically pertain to the use of Ferrules-- Ferrules are covered under DIN VDE 0611. Non-Insulated Tube: soft electrolytic copper (E-CU), tin plated Plastic sleeve: polypropylene Long-term temperature 105C Short-term temperature 120C 8 Tube: soft electrolytic copper (E-CU), tin plated XBAF20 Insulated Ferrules Non-Insulated Ferrules Wire Size AWG (mm2) Standard Pack 2 Catalog Number 20 (0.5) 100 XBAF20 Catalog Number 18 (0.75) 100 XBAF21 Color 1 Standard Pack 2 18 (1) 100 XBAF23 20 (0.5) White 100 XBAF1 16 (1.5) 100 XBAF24 18 (0.75) Gray 100 XBAF3 14 (2.5) 100 XBAF25 18 (1) Red 100 XBAF4 12 (4) 100 XBAF26 16 (1.5) Black 100 XBAF6 10 (6) 100 XBAF27 14 (2.5) Blue 100 XBAF9 8 (10) 100 XBAF28 8 14 (2.5) Blue 100 XBAF10 6 (16) 100 XBAF29 12 (4) Gray 100 XBAF11 8 12 (4) Gray 100 XBAF12 10 (6) Yellow 100 XBAF13 Special Applications 10 (6) Yellow 100 XBAF14 8 8 (10) Red 100 XBAF15 8 (10) Red 100 XBAF16 The twin ferrules allow two conductors to be compressed practically in one ferrule. 8 6 (16) Blue 100 XBAF17 6 (16) Blue 100 XBAF18 4 (25) Yellow 50 XBAF19 XBAF1 8 8 8 8 8 8 8 Wire Size AWG (mm2) XBAFT1 The colored coding of the various cross sections corresponds to DIN 46 228-4. Non-Insulated Twin Ferrules Wire Size AWG (mm2) Color 1 Standard Pack 2 Catalog Number 20 (0.5) 18 (0.75) White 100 XBAFT1 Gray 100 XBAFT3 8 18 (1) Red 100 XBAFT4 16 (1.5) Black 100 XBAFT6 8 14 (2.5) Blue 100 XBAFT9 12 (4) Gray 100 XBAFT11 10 (6) Yellow 100 XBAFT13 8 (10) Red 100 XBAFT15 6 (16) Blue 50 XBAFT18 8 8 8 Notes 1 The colored coding of the various cross-sections corresponds to DIN 46 228-4. 2 Standard pack is the number of ferrules that come in each bag. Must order in multiples of standard pack. Example: XBAF1--an order for 200 pieces will receive 2 bags of ferrules, each with 100 pieces. 8 8 8 8 8 V7-T8-94 Volume 7--Logic Control, Operator Interface and Connectivity Solutions CA08100008E--November 2011 www.eaton.com Terminal Blocks, Fuse Blocks and Fuse Holders IEC--XB Series 8.1 Dimensions Approximate Dimensions in Inches (mm) 8 Ferrules with Insulating Collar 8 8 L1 L2 S1 8 D1 D2 8 S2 8 Catalog Number Approximate Dimensions D1 D2 L1 L2 S1 S2 XBAF1 0.04 (1.1) 0.10 (2.5) 0.55 (14.0) 0.31 (8.0) 0.006 (0.15) 0.010 (0.25) XBAF3 0.05 (1.3) 0.11 (2.8) 0.55 (14.0) 0.31 (8.0) 0.006 (0.15) 0.010 (0.25) XBAF4 0.06 (1.5) 0.12 (3.0) 0.55 (14.0) 0.31 (8.0) 0.006 (0.15) 0.012 (0.30) XBAF6 0.07 (1.8) 0.13 (3.4) 0.55 (14.0) 0.31 (8.0) 0.006 (0.15) 0.012 (0.30) XBAF9 0.09 (2.3) 0.17 (4.2) 0.55 (14.0) 0.31 (8.0) 0.006 (0.15) 0.012 (0.30) XBAF10 0.09 (2.3) 0.17 (4.2) 0.94 (24.0) 0.71 (18.0) 0.006 (0.15) 0.012 (0.30) XBAF11 0.11 (2.8) 0.19 (4.8) 0.67 (17.0) 0.39 (10.0) 0.008 (0.20) 0.012 (0.30) XBAF12 0.11 (2.8) 0.19 (4.8) 1.02 (26.0) 0.71 (18.0) 0.008 (0.20) 0.012 (0.30) XBAF13 0.14 (3.5) 0.24 (6.2) 0.79 (20.0) 0.47 (12.0) 0.008 (0.20) 0.012 (0.30) XBAF14 0.14 (3.5) 0.24 (6.2) 1.02 (26.0) 0.71 (18.0) 0.008 (0.20) 0.012 (0.30) XBAF15 0.18 (4.6) 0.30 (7.5) 0.87 (22.0) 0.47 (12.0) 0.008 (0.20) 0.012 (0.30) XBAF16 0.18 (4.6) 0.30 (7.5) 1.10 (28.0) 0.71 (18.0) 0.008 (0.20) 0.012 (0.30) XBAF17 0.23 (5.8) 0.35 (8.8) 0.94 (24.0) 0.47 (12.0) 0.008 (0.20) 0.016 (0.40) XBAF18 0.23 (5.8) 0.35 (8.8) 1.10 (28.0) 0.71 (18.0) 0.008 (0.20) 0.016 (0.40) XBAF19 0.29 (7.3) 0.43 (11.0) 1.26 (32.0) 0.71 (18.0) 0.008 (0.20) 0.020 (0.50) 8 8 8 8 8 8 8 8 8 8 8 Ferrules without Insulating Collar 8 L1 L2 8 D2 D1 8 S 8 Catalog Number Approximate Dimensions D1 D2 L1 L2 S XBAF20 0.04 (1.0) 0.08 (2.1) 0.24 (6.0) 0.21 (5.3) 0.006 (0.15) XBAF21 0.05 (1.2) 0.09 (2.3) 0.24 (6.0) 0.21 (5.3) 0.006 (0.15) XBAF23 0.06 (1.4) 0.10 (2.5) 0.24 (6.0) 0.21 (5.3) 0.006 (0.15) XBAF24 0.07 (1.7) 0.11 (2.8) 0.28 (7.0) 0.24 (6.0) 0.006 (0.15) XBAF25 0.09 (2.2) 0.13 (3.4) 0.28 (7.0) 0.24 (6.0) 0.006 (0.15) XBAF26 0.11 (2.8) 0.16 (4.0) 0.35 (9.0) 0.31 (8.0) 0.008 (0.20) XBAF27 0.14 (3.5) 0.19 (4.7) 0.47 (12.0) 0.35 (9.0) 0.008 (0.20) XBAF28 0.18 (4.5) 0.23 (5.8) 0.47 (12.0) 0.43 (10.8) 0.008 (0.20) XBAF29 0.23 (5.8) 0.30 (7.5) 0.47 (12.0) 0.41 (10.5) 0.008 (0.20) 8 8 8 8 8 8 8 8 8 Volume 7--Logic Control, Operator Interface and Connectivity Solutions CA08100008E--November 2011 www.eaton.com V7-T8-95 8.1 Terminal Blocks, Fuse Blocks and Fuse Holders IEC--XB Series 8 Approximate Dimensions in Inches (mm) 8 Twin Ferrules L1 8 L2 8 D2 D1 8 8 8 S1 S2 Catalog Number Approximate Dimensions D1 D2 L1 L2 S1 S2 XBAFT1 0.06 (1.5) 0.10 (2.5) 0.59 (15.0) 0.31 (8.0) 0.006 (0.15) 0.010 (0.25) XBAFT3 0.07 (1.8) 0.11 (2.8) 0.59 (15.0) 0.31 (8.0) 0.006 (0.15) 0.010 (0.25) XBAFT4 0.08 (2.1) 0.13 (3.4) 0.59 (15.0) 0.31 (8.0) 0.006 (0.15) 0.012 (0.30) XBAFT6 0.09 (2.3) 0.14 (3.6) 0.63 (16.0) 0.31 (8.0) 0.006 (0.15) 0.012 (0.30) 8 XBAFT9 0.11 (2.9) 0.17 (4.2) 0.73 (18.5) 0.39 (10.0) 0.008 (0.20) 0.012 (0.30) XBAFT11 0.15 (3.8) 0.19 (4.9) 0.91 (23.0) 0.47 (12.0) 0.008 (0.20) 0.012 (0.30) 8 XBAFT13 0.19 (4.9) 0.23 (5.9) 0.98 (25.0) 0.55 (14.0) 0.008 (0.20) 0.016 (0.40) XBAFT15 0.26 (6.5) 0.28 (7.2) 1.02 (26.0) 0.55 (14.0) 0.008 (0.20) 0.016 (0.40) 8 XBAFT18 0.33 (8.5) 0.35 (8.8) 1.22 (31.0) 0.63 (16.0) 0.008 (0.20) 0.020 (0.50) 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 V7-T8-96 Volume 7--Logic Control, Operator Interface and Connectivity Solutions CA08100008E--November 2011 www.eaton.com 8.1 Terminal Blocks, Fuse Blocks and Fuse Holders IEC--XB Series Hand Tools 8 Stripping Tools Product Selection Stripping Tools 8 Dimensions 8 Approximate Dimensions in Inches (mm) Standard Pack Catalog Number 1 XBTCUTSTP Stripping Tools Technical Data and Specifications Conductor/Cable Stripping Range Description Specification Conductor/cable 0.2-6 mm2/24-10 AWG Wire cutter 6 mm2/10 AWG Length Stripping Length Weight In lbs (g) 8.07 (205) Up to 18 mm 0.44 (200) 8 8 8 8 8 8 8 Crimping Pliers 8 The crimping pliers deform the ferrules hexagonally. For 0.25-6 mm2 ferrules in accordance with DIN 46 228-1: 1992-08 and DIN 46 228-4: 1990-09. Product Selection Crimping Pliers Standard Pack Catalog Number 1 XBTCRMP66 Dimensions 8 Approximate Dimensions in Inches (mm) Crimping Pliers Length Weight In lbs (g) 6.85 (175) 0.79 (360) 8 8 8 8 Technical Data and Specifications Areas of Application Description Specification Conductor 0.25-6 mm2 Conductor 23-10 AWG 8 8 8 8 8 Slotted Screwdrivers 8 The crimping pliers deform the ferrules hexagonally. For 0.25-6 mm2 ferrules in accordance with DIN 46 228-1: 1992-08 and DIN 46 228-4: 1990-09. 8 8 Product Selection Slotted Screwdrivers Standard Pack 8 Catalog Number 8 3.5 mm 1 XBTDVR35 8 XBTDVR40 8 4.0 mm 1 8 8 Volume 7--Logic Control, Operator Interface and Connectivity Solutions CA08100008E--November 2011 www.eaton.com V7-T8-97 8.1 Terminal Blocks, Fuse Blocks and Fuse Holders IEC--XB Series Printed Marking Tag Options 8 Horizontally Printed Marking Tags and Marking Directions 8 8 3 4 5 6 7 8 9 10 10 6 5 4 3 2 8 2 Marking Direction: Horizontal 1 8 1 9 8 8 Marking Accessories 7 8 Marking Direction: Vertical 8 8 8 8 8 8 8 Marking Tags for 5.2 mm Wide Terminal Blocks Marking Tags for 6.2 mm Wide Terminal Blocks Standard Pack Standard Pack Number Sequence Catalog Number ZB5 Tags Vertically Numbered Number Sequence Catalog Number ZB6 Tags Vertically Numbered 10 1-10 1 XBMZB5V/1 10 1-10 1 XBMZB6V/1 10 11-20 XBMZB5V/11 10 11-20 XBMZB6V/11 XBMZB6V/21 10 21-30 XBMZB5V/21 10 21-30 10 31-40 XBMZB5V/31 10 31-40 XBMZB6V/31 10 41-50 XBMZB5V/41 10 41-50 XBMZB6V/41 10 51-60 XBMZB5V/51 10 51-60 XBMZB6V/51 10 61-70 XBMZB5V/61 10 61-70 XBMZB6V/61 8 10 71-80 XBMZB5V/71 10 71-80 XBMZB6V/71 10 81-90 XBMZB5V/81 10 81-90 XBMZB6V/81 8 10 91-100 XBMZB5V/91 10 91-100 XBMZB6V/91 8 8 8 8 8 8 ZBF5 Tags Vertically Numbered ZBF6 Tags Vertically Numbered 10 1-10 1 XBMZBF5V/1 10 1-10 1 XBMZBF6V/1 10 11-20 XBMZBF5V/11 10 11-20 XBMZBF6V/11 10 21-30 XBMZBF5V/21 10 21-30 XBMZBF6V/21 10 31-40 XBMZBF5V/31 10 31-40 XBMZBF6V/31 10 41-50 XBMZBF5V/41 10 41-50 XBMZBF6V/41 10 51-60 XBMZBF5V/51 10 51-60 XBMZBF6V/51 10 61-70 XBMZBF5V/61 10 61-70 XBMZBF6V/61 10 71-80 XBMZBF5V/71 10 71-80 XBMZBF6V/71 10 81-90 XBMZBF5V/81 10 81-90 XBMZBF6V/81 10 91-100 XBMZBF5V/91 10 91-100 XBMZBF6V/91 8 Note 1 For text printed horizontally, change "V" in catalog number to "H." 8 8 8 8 8 8 8 V7-T8-98 Volume 7--Logic Control, Operator Interface and Connectivity Solutions CA08100008E--November 2011 www.eaton.com Terminal Blocks, Fuse Blocks and Fuse Holders IEC--XB Series Marking Tags for 8.2 mm Wide Terminal Blocks Marking Tags for 12 mm Wide Terminal Blocks Standard Pack Standard Pack Number Sequence Catalog Number Number Sequence 8.1 8 Catalog Number 8 ZB12 Tags Vertically Numbered ZB8 Tags Vertically Numbered 10 1-10 1 XBMZB8V/1 10 1-10 1 XBMZB12V/1 10 11-20 XBMZB8V/11 10 11-20 XBMZB12V/11 21-30 XBMZB12V/21 8 8 10 21-30 XBMZB8V/21 10 10 31-40 XBMZB8V/31 ZBF12 Tags Vertically Numbered 10 41-50 XBMZB8V/41 10 1-10 1 XBMZBF12V/1 10 51-60 XBMZB6V/51 10 11-20 XBMZBF12V/11 10 61-70 XBMZB8V/61 10 21-30 XBMZBF12V/21 10 71-80 XBMZB8V/71 10 81-90 XBMZB8V/81 10 91-100 XBMZB8V/91 10 1-10 1 XBMZBF8V/1 10 11-20 XBMZBF8V/11 10 21-30 XBMZBF8V/21 10 31-40 XBMZBF8V/31 10 41-50 XBMZBF8V/41 10 51-60 XBMZBF8V/51 10 61-70 XBMZBF8V/61 10 71-80 XBMZBF8V/71 10 81-90 XBMZBF8V/81 10 91-100 XBMZBF8V/91 8 8 Marking Tags for 16 mm Wide Terminal Blocks Standard Pack ZBF8 Tags Vertically Numbered 8 Number Sequence 8 Catalog Number 8 ZB15 Tags Vertically Numbered 8 10 1-10 1 XBMZB15V/1 10 11-20 XBMZB15V/11 10 21-30 XBMZB15V/21 8 XBMZBF15V/1 8 ZBF15 Tags Vertically Numbered 10 1-10 1 10 11-20 XBMZBF15V/11 10 21-30 XBMZBF15V/21 8 8 Note 1 For text printed horizontally, change "V" in catalog number to "H." 8 8 Marking Tags for 10.2 mm Wide Terminal Blocks Standard Pack Number Sequence Catalog Number 8 ZB10 Tags Vertically Numbered 10 1-10 1 XBMZB10V/1 10 11-20 XBMZB10V/11 10 21-30 XBMZB10V/21 8 8 ZBF10 Tags Vertically Numbered 10 1-10 1 XBMZBF10V/1 10 11-20 XBMZBF10V/11 10 21-30 XBMZBF10V/21 8 8 8 8 8 8 8 8 8 8 8 Volume 7--Logic Control, Operator Interface and Connectivity Solutions CA08100008E--November 2011 www.eaton.com V7-T8-99 8.1 8 8 8 Terminal Blocks, Fuse Blocks and Fuse Holders IEC--XB Series Pre-Printed Marking Tags Terminal Blocks Marking Tags The tags are made of white self-extinguishing polyamide 6.6 and the imprint is hot stamped with rubproof black ink. 8 8 8 8 White marking strip available preprinted. Strip covers 10 terminals. Marking 1 - 10, 11-20, up to 991-999. Contact Eaton for more options. XBMZB5 or XBMZBF5 for terminal blocks 5.2 mm wide XBMZB6 or XBMZBF6 for terminal blocks 6.2 mm wide XBMZB8 or XBMZBF8 for terminal blocks 8.2 mm wide XBMZB10 or XBMZBF10 for terminal blocks 10.2 mm wide XBMZB12 or XBMZBF12 for terminal blocks 12 mm wide XBMZB15 or XBMZBF15 for terminal blocks 16 mm wide 8 8 8 Marking Tag Sizes Note: Marking Tag Sizes are for all catalog numbers starting with given prefix, EXCEPT FUSE TERMINAL Blocks. Proper Marking Tag Size XBMZB5 XBMZBF5 XBMZB6 XBMZBF6 XBMZB8 XBMZBF8 XBMZB10 XBMZBF10 XBMZB12 XBMZBF12 XBMZB15 XBMZBF15 XBMSSZB XBUT25 XBPT25 2 XBUT4 XBPT4 2 XBUT6 XBPT6 2 XBUT10 XBPT10 2 XBPT16 1 XBPT16 2 XBUT35 XBPT35 2 XBMKLMZ XBUT4FBE 1 XBPTT25 XBUTT4 XBPTT4 XBPT6 1 XBPT4FBN 2 XBUT16 -- -- -- XBPT35 1 -- -- XBUT6FBN 1 XBPTK XB3UKA XBPT4FBE 2 XBUK6 XBPT4FSI 2 XBTK -- -- -- -- -- -- XBPT25 1 XBPU25 2 XB3UKF XBQT25 3 XBPT4FSI 1 -- XBUK50 -- -- -- -- -- -- 8 XBPT4FBE 1 XBAP ... XBUT4FBE 2 XBQT25FBE 3 -- -- XBUK150 -- -- -- -- -- -- XBQU25 3 -- -- XBUK95 -- -- -- -- -- -- 8 XBQT15 1 XBUK10 -- -- -- XBPT10 1 -- -- -- -- -- -- XBUKK4 -- -- -- XBMKLMZ 5 -- -- -- -- -- -- 8 8 8 XBPU25 1 XBQT15 3 XBQTT15 XBQT25FBE 4 XBQU15 XBQU15 1 XBMPK15 XBPT4 1 -- -- -- -- -- -- -- -- -- -- XBMUK25 XBMPKK15 XBPT4FBN 1 -- -- -- -- -- -- -- -- -- -- -- XBATCP... XBQT25 1 -- -- -- -- -- -- -- -- -- -- 8 -- -- XBQT25FBE 1 -- -- -- -- -- -- -- -- -- -- -- -- XBQU25 8 -- -- XBMUK4 8 Notes 1 For center labeling. 2 For external labeling. 3 For center and outside labeling. 4 For lever labeling. 5 Two (2) XBMZB10 tags fit in one (1) XBMKLMZ. 8 8 8 8 3 XBUT6FBN 2 1 -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- 8 8 8 8 8 8 8 8 V7-T8-100 Volume 7--Logic Control, Operator Interface and Connectivity Solutions CA08100008E--November 2011 www.eaton.com 8.1 Terminal Blocks, Fuse Blocks and Fuse Holders IEC--XB Series Marker Strips and Sheets (for use with XBAPLT2006K1 plotter) The XB Series marking system provides logical and clear identification of the modular terminal blocks and interface modules. 8 8 Product Selection XBMZB_ 8 Marker Sheets (Strip of 10) Marker Strips (Strip of 10) Terminal Width Standard Pack XBMPZB_ Blank Strips 5.2 mm Terminal Width) Catalog Number 10 Stnd. Pack 8 Catalog Number 8 Marker Sheets (10 rows of 12) 5.2 mm XBMZB5 Color White 50 XBMPZB5 50 XBMPZB5BU 6.2 mm 10 XBMZB6 Blue 8.2 mm 10 XBMZB8 Red 50 XBMPZB5RD 50 XBMPZB5YE 50 XBMPZB5GN 10.2 mm 10 XBMZB10 Yellow 12 mm 10 XBMZB12 Green 16 mm 10 XBMZB15 1 Marker Sheets (10 rows of 10) 6.2 mm Flat Strips White 50 XBMPZB6 5.2 mm 10 XBMZBF5 Blue 50 XBMPZB6BU 6.2 mm 10 XBMZBF6 Red 50 XBMPZB6RD 8.2 mm 10 XBMZBF8 Yellow 50 XBMPZB6YE Green 50 XBMPZB6GN 10.2 mm 10 XBMZBF10 12 mm 10 XBMZBF12 16 mm 10 XBMZBF15 XBMPZBF_ Flat Marker Sheets (10 rows of 10) 5.2 mm White 10 XBMPZBF5 Orange 10 XBMPZBF5OG White 10 XBMPZBF6 Orange 10 XBMPZBF6OG White 10 XBMPZBF8 8 8 8 8 8 8 8 8 8 8 8 Label Sheets for Laser Printers The XBM labels have been specially developed for laser printers and have considerable advantages: Can be printed on all commercially available laser printers Or can use plotter or pen for printing Good adhesive properties A4 size XBMKL25X12WH designed to fit XBGBS2512 group marker XBMLMAL447 is perforated for terminal strip marker XBMGLMA and is 44 x 7 mm 8 8 Product Selection XBM_ 8 Label Sheets Standard Pack Catalog Number 8 10 XBMKL25X12WH 10 XBMLMAL447 8 8 8 Note 1 All markers are strips of 10, except XBMZB15, which is a strip of 5. 8 8 8 8 8 8 8 Volume 7--Logic Control, Operator Interface and Connectivity Solutions CA08100008E--November 2011 www.eaton.com V7-T8-101 8.1 Terminal Blocks, Fuse Blocks and Fuse Holders IEC--XB Series Terminal Block Group Marking Terminal block groups are marked using marking labels that are snapped into the marker strip groove of the terminal blocks. The group is marked using either labels or insert markers. Insert Markers for Laser Printers One sheet = 56 labels. Lettering field is 40 x 17 mm. 8 Product Selection XBMUBEL4017 8 XBGBS2512 8 8 8 Product Selection Insert Markers for XBMUBE(D) Terminal Block Group Marking 1 Standard Pack Catalog Number Standard Pack Catalog Number 10 XBMUBEL4017 100 XBGBS2512 8 8 8 8 Terminal Strip Markers Adjustable height for end bracket labeling. 8 Product Selection 8 Product Selection Terminal Strip Markers 1 XBM_ Standard Pack 8 Catalog Number XBMXPEN 10 10 Catalog Number Pen XBMKLM2 1 44 x 7 mm Wide 8 Terminal Strip Markers 1 Standard Pack 20 x 8 mm Wide 8 8 Refillable Marker Pen Refillable marker pen for manual labeling, line thickness 0.35 mm. XBMXPEN Ink Cartridge XBMGLMA 1 XBMINK 8 Terminal Strip Marker Carriers For labeling terminal groups, for mounting on DIN rail. Lettering field is 40 x 17 mm. Non-Refillable Marker Pen For manual labeling, line thickness 0.5 mm. 8 Product Selection Product Selection 8 XBMUB_ 8 8 8 Terminal Strip Marker Carriers XBMUBE Non-Refillable Marker Pen Standard Pack Catalog Number Standard Pack 10 XBMUBE 1 10 XBMUBED Catalog Number XBMBSTIFT Note 1 See Page V7-T8-101 for insert labels. 8 8 8 8 8 8 8 8 8 V7-T8-102 Volume 7--Logic Control, Operator Interface and Connectivity Solutions CA08100008E--November 2011 www.eaton.com 8.1 Terminal Blocks, Fuse Blocks and Fuse Holders IEC--XB Series Marking Plotter The automatic Prepare Pen function ensures optimum marking results right from the first character. 8 Pens can remain in the pen station even for prolonged intervals without drying out. 8 8 Custom Marking Tag System This plotter system uses Windows(R)-based software to interface with a PC, allowing custom printing on standard terminal blocks marking tags. These standard marking tags provide circuit identification for Eaton DIN rail mount terminal blocks. Features Enter tag text directly into EMARK software program or import file from AutoCAD or Excel(R) Selectable font sizes, types and colors including common symbols for circuit identification (ground, ~ etc.) Various text formatting options including copy, paste, increment functions, text alignment, etc. Durable templates allow printing of four different tag sizes at the same time Automatic prepare pen function for optimum results Technical Data and Specifications 8 Marking Plotter 8 Description Specification 8 Plotter Plotter type Flatbed plotter Maximum plotting surface 440 mm x 296 mm Maximum material height 10.5 mm Maximum plotting speed 40 cm/sec Pen station Four depots with double sealing Drive Two-phase impulse-driven motor Interfaces Parallel (Centronics)/USB Level 1.1 8 Based on HP-GL 7475A 8 8 8 8 Electronics Command language Data buffer 16 MB Addressable resolution 0.01 mm Repeat accuracy 0.05 mm Repeat accuracy on pen change 0.05 mm with optimum pen 8 8 8 Power Supply Power supply Via separate power supply unit with exchangeable mains feeder cable Power supply unit input voltage 100-240 Vac/50-60 Hz Power supply unit input current (maximum) 0.3A at 230V~ Power supply unit output voltage 24 Vdc Power supply unit output current (maximum) 1.4A 8 8 8 8 Environmental conditions Operation 50 to 95F (10 to 35C) 35% to 75% relative humidity Storage 14 to 122F (-10 to 50C) 10% to 90% relative humidity 8 8 Dimensions 8 Approximate Dimensions in Inches (mm) 8 Marking Plotter Approx. Weight L W H In Lbs (kg) 25.98 (660) 17.32 (440) 4.92 (125) 18 (8) 8 8 8 8 8 8 8 8 Volume 7--Logic Control, Operator Interface and Connectivity Solutions CA08100008E--November 2011 www.eaton.com V7-T8-103 8.1 Terminal Blocks, Fuse Blocks and Fuse Holders IEC--XB Series Marking Plotter 8 Description Standard Pack Catalog Number Plotter kit 1 1 XBAPLT2006K1 8 Pen station sealing set 1 XBMP1PENDEPOT Plotter pen preparation plate 1 XBMP1PREPLATES 8 Template for marker strips 1 XBMP1MZB Template for flat marker strips 1 XBMP1MZBF Template for XBMPZB marker sheets 1 XBMP1MPZB 8 Template for XBMPZBF marker sheets 1 XBMP1MPZBF Template for Weidmuller multicard sheet 1 XBMP1MCSF46 8 Template for Weidmuller multicard sheet universal 1 XBMP1MCU Template for Entrelec sheets 1 XBMP1MRC 0.25 mm disposal pen 1 XBMDPEN25R 0.35 mm disposal pen 1 XBMDPEN35R 0.25 mm pen 1 XBMPEN25 8 0.35 mm pen 1 XBMPEN35 Ink Cartridge 2 XBMINK 8 Pen cleaning set 1 XBMRSET Cleaning cartridges 2 XBMRMEKFC2 8 8 8 8 8 8 EMARK Software Eaton's EMARK software makes labeling your terminal blocks quick and simple. You can import your data from ECHART, any other CAD/CAE program, or enter text directly into EMARK. The software allows marking tags to be printed on the PLT2006 plotter in a professional manner. 8 8 8 8 Note 1 Plotter kit includes PLT2006 plotter system with EMARK software and user manual, starter ink and cleaning sets, and templates for marking all XBMZB and XBMZBF tags. 8 8 8 8 8 8 8 8 8 8 8 8 8 V7-T8-104 Volume 7--Logic Control, Operator Interface and Connectivity Solutions CA08100008E--November 2011 www.eaton.com Terminal Blocks, Fuse Blocks and Fuse Holders IEC--XB Series Testing Accessories Separating Plates, Covers and Bridges Test Adapter For 4 mm diameter test plug and 4 mm diameter safety test plug. Makes contact in the bridge shaft. Product Selection Test Adapter XBATSPAI4 Standard Pack Catalog Number 1 XBATSPAI4 Modular Test Plugs For individual assembly of test plug strips. Product Selection Modular Test Plugs XBATS_ 8.1 Standard Pack Catalog Number Test Plugs 10 XBATSPS5 10 XBATSPS6 10 XBATSPS8 Spacer Plate 10 XBATSDPPS5 10 XBATSDPPS6 10 XBATSDPPS8 8 End Cover Used to cover an open end of terminal block when changing sizes within an assembly and/ or for last terminal block in a row. 8 End Cover Segment Covers protruding terminal block segments of three- and four-wire terminal blocks when next to a two wire blocks. This ensures that all is touch-proof and saves space over using a standard end cover. 8 Jumper/Bridge Provides the ability to electrically connect terminal blocks. Non-adjacent blocks may be bridged by snapping off the contact tabs of the standard bridge. The reducing bridge permits simple connection of terminal blocks with different nominal cross-sections. 8 Note See these accessories as listed with terminal blocks for more information. 8 8 8 8 8 8 8 8 8 8 8 8 8 Product Selection 8 Test Plugs Standard Pack XBATSMP_ 8 Partition Plate Protrudes over the terminal block and is used to increase electrical clearance between terminals. Also provides visual indications of the functions of terminal blocks. For example, terminal blocks between two partition plates may provide an exact location for test points. Test Plugs Consisting of metal part for socket hole and insulating sleeve. XBATSMP_ 8 8 Catalog Number 8 2.3 mm 10 -- XBATSMPSMT 10 Blue XBATSMPSIHBU 10 White XBATSMPSIHWH 10 Red XBATSMPSIHRD 10 Black XBATSMPSIHBK 8 10 -- XBATSPSMT 8 10 Blue XBATSPSIHBU 10 White XBATSPSIHWH 10 Red XBATSPSIHRD 10 Black XBATSPSIHBK 8 8 4 mm 8 8 8 8 Volume 7--Logic Control, Operator Interface and Connectivity Solutions CA08100008E--November 2011 www.eaton.com V7-T8-105 8.2 8 Terminal Blocks, Fuse Blocks and Fuse Holders NEMA Contents NEMA Description 8 NEMA C381 Series Terminal Blocks, Rail Mounted . . TB Series Terminal Blocks, Modular . . . . . . . . . 8 8 8 8 8 8 8 8 8 NEMA Overview 8 Product Description Standards and Certifications NEMA terminal blocks provide a panel or DIN rail mount block that can be assembled from modular pieces. These blocks accommodate wire from 22 to 1/0 AWG and up to 175A and 600V. 8 8 8 8 UL File #E67464 and #E56797 8 8 8 8 8 8 8 8 8 8 8 8 8 8 V7-T8-106 Volume 7--Logic Control, Operator Interface and Connectivity Solutions CA08100008E--November 2011 www.eaton.com Page V7-T8-107 V7-T8-111 Terminal Blocks, Fuse Blocks and Fuse Holders NEMA 8.2 Contents C381 Series Terminal Blocks, Rail Mounted Description Page C381 Series Terminal Blocks, Rail Mounted Product Selection . . . . . . . . . . . . . . . . . . . . . . . Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . Modifications . . . . . . . . . . . . . . . . . . . . . . . . . . Technical Data and Specifications . . . . . . . . . . Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . TB Series Terminal Blocks, Modular . . . . . . . . . . . . 8 8 V7-T8-108 V7-T8-109 V7-T8-109 V7-T8-110 V7-T8-110 V7-T8-111 8 8 8 8 8 8 8 8 8 C381 Series Terminal Blocks, Rail Mounted Product Description Standards and Certifications 600V Snap-fit nylon sections Control circuit blocks Power circuit blocks Fuse blocks Switch blocks Sections can be interlocked in any quantity and any mixture for direct panel mounting or channel mounting Three terminal choices in control circuit blocks, up to 32 circuits per foot Power circuit blocks for heavy-duty applications, up to 16 circuits per foot Fuse blocks accommodate any 0.406 x 1.5 in (10.3 x 38.1 mm) ferrule type cartridge fuse up to 30A Switch blocks have removable blade for extra safety UL File #E67464 8 8 8 8 8 8 A Typical Mixture of Control Circuit Blocks, Power Blocks, Switch and Fuse Blocks in a Mounting Channel C381TP C381PE C381PT 8 8 C381EF C381SB C381FB 8 C381CC 8 C381MC 8 8 8 8 8 8 8 8 8 Volume 7--Logic Control, Operator Interface and Connectivity Solutions CA08100008E--November 2011 www.eaton.com V7-T8-107 8.2 8 8 8 Terminal Blocks, Fuse Blocks and Fuse Holders NEMA Product Selection When Ordering Specify Catalog number and quantity, which must be in a multiple of the available minimum standard package. 8 Examples: 200 Cat. No. C381ST 20 Cat. No. C381PT 100 Cat. No. C381CC 8 Control, Power, Switch and Fuse Blocks 1 8 Description 8 AWG Wire Size Catalog number and quantity of end sections also in minimum quantity standard package. Standard Pack 2 Catalog Number Example: 25 Cat. No. C381ES. Control Circuit Terminal Blocks--Rated 50A C381ST Type ST (screw terminal) 22-14 AWG 100 C381ST C381TP Type TP (tubular pressure plt) 22-10 100 C381TP C381TS Type TS (tubular screw) end section 18-8 100 C381TS C381ES End section -- 25 C381ES 8 8 8 8 8 8 8 8 8 8 Power Circuit Terminal Blocks--Rated 155A C381PT Type PT (tubular screw) 10-1/0 10 C381PT C381PE End section -- 10 C381PE 8 8 8 8 8 Switch Blocks--Rated 15A and Fuse Blocks--Rated 30A C381SB Switch blocks 18-8 10 C381SB C381FB Fuse blocks 18-8 10 C381FB C381EF End section -- 10 C381EF 8 8 8 8 8 8 Notes 1 Available only in minimum quantity standard packages. 2 Must be ordered in standard package quantity or in multiples of these quantities. 8 8 V7-T8-108 Volume 7--Logic Control, Operator Interface and Connectivity Solutions CA08100008E--November 2011 www.eaton.com Terminal Blocks, Fuse Blocks and Fuse Holders NEMA 8.2 Accessories C381 Series Terminal Blocks, Rail Mounted 8 1 Description Standard Pack 2 Catalog Number Aluminum mounting channel--6 ft (1.8m) lengths 25 C381MC Screw type channel clamp (one required each end) 3 100 C381VC Spring type channel clamp (one required each end) 3 100 C381CC Vinyl marking strip--3/8 in x 25 ft (9.5 mm x 7.6m) coil 1 C381MS Marking paper--pressure sensitive--5/16 x 11-11/16 in (7.9 x 296.9 mm), 24 strips/sheet 5 sheets C381MP For use on control circuit blocks 100 C381SR For use on power circuit blocks 100 C381SP 8 8 8 8 8 Marking strip retainer (one required/grouping) Fanning strip--for type TP and/or TS 50 C381TF Fanning strip--for type ST 50 C381SF Terminal jumper (two-pole) 4 100 C381TJ Ganging rod--1/8 in x 6 in (3.2 mm x 152.4 mm) 5 10 C381GR 8 8 8 8 8 Modifications 8 Pull Apart Terminal Blocks 1 Description AWG Wire Size Standard Pack 2 Catalog Number One-pole stationary section (tubular pressure plt) 22-10 100 C381PS Three-pole movable section (tubular pressure plt) 22-10 12 C381PM End section -- 25 C381ES Polarizing plug (promotes alignment of poles) 6 -- 100 C381PP 8 8 8 8 Pull Apart Terminal Blocks 8 8 8 8 8 8 Illustrates: One-Three-Pole Movable Section, Three-One-Pole Stationary Sections and One-End Piece 8 Notes 1 Available only in minimum quantity standard packages. 2 Must be ordered in standard package quantity or in multiples of these quantities. 3 C381CC is a snap-in, one time use disposable type. C381VC can be readjusted or reused as desired. 4 For use on adjacent Type TP and/or TS control circuit sections. 5 May be used on section covers or to gang fuse and/or switch blocks. 6 L shaped plug installs in end of stationary section, Catalog Number C381PS, and prevents incorrect installation of movable section, Catalog Number C381PM. 8 8 8 8 8 8 8 Volume 7--Logic Control, Operator Interface and Connectivity Solutions CA08100008E--November 2011 www.eaton.com V7-T8-109 8.2 8 Terminal Blocks, Fuse Blocks and Fuse Holders NEMA Technical Data and Specifications 8 Formulas for Calculating Blocks and Channel Lengths N = Number of Blocks 8 C381 Series Terminal Blocks, Rail Mounted 8 Description Blocks Length Control blocks and pull apart blocks 0.762 + (0.375 x N) 8 Power circuit blocks 0.812 + (0.750 x N) Fuse and switch blocks 0.812 + (0.755 x N) 8 Mounting channel (minimum channel length) 0.75 + blocks length 8 Dimensions 8 Approximate Dimensions in Inches (mm) 8 C381 Series Terminal Blocks, Rail Mounted Terminal Block Mounting Without Channel 8 Channel Mounting 8 8 1.19 (30.2) A 8 Mounting Channel in 6' (1.8m) Lengths, Can Be Cut to Desired Length 8 8 B Block A 8 Control circuit blocks 1.25 (31.8) 1.55 (39.4) Power circuit blocks 1.75 (44.5) 2.00 (50.8) 8 Fuse blocks 2.75 (69.9) 2.00 (50.8) Switch blocks 2.75 (69.9) 2.00 (50.8) Pull apart blocks 1.88 (47.8) 2.75 (69.9) 8 B 8 8 8 8 8 8 8 8 8 8 8 8 V7-T8-110 Volume 7--Logic Control, Operator Interface and Connectivity Solutions CA08100008E--November 2011 www.eaton.com Terminal Blocks, Fuse Blocks and Fuse Holders NEMA 8.2 Contents TB Series Terminal Blocks, Modular Description Page C381 Series Terminal Blocks, Rail Mounted . . . . . TB Series Terminal Blocks, Modular Product Selection . . . . . . . . . . . . . . . . . . . . . . . Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . Technical Data and Specifications . . . . . . . . . . Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . V7-T8-107 V7-T8-112 V7-T8-113 V7-T8-114 V7-T8-115 8 8 8 8 8 8 8 8 8 8 8 TB Series Terminal Blocks, Modular Product Description Features TBA and TBD modular terminal blocks are designed to conserve space, while allowing maximum flexibility and ease of installation. Available as one-, two- and three-pole circuits, simple and uniform installation is possible because their design is based on 5/8 in (15.9 mm) modules. Standard blocks are white nylon. Blocks--Design Features Compact design permits mounting 48-600V or 90-300V terminals per foot Fully shielded construction, 600V spacings Nylon construction provides anti-tracking and impact resistance TBA types are available in rail mounted, base mounted and power distribution types Terminal blocks easily snap on or off mounting rails; not necessary to disturb adjacent units No end pieces or backing plates are needed when rail mounting A 12 circuit subminiature blocks, rated 20A at 300V, is available for "high density" applications Popular blocks are also available in dual mount for use with standard TBA or 35 mm DIN rails Breathing Action Clamping Collar The unique design of the clamping collar permits the collar to breathe as the wire expands and contracts, maintaining a constant and permanent clamping pressure. This eliminates loose connections resulting from the gradual flattening of conductors and joint deterioration caused by heating and cooling cycles. Terminals--Design Features Insulated walls of lug guide wire into lug Blocks are shipped with clamping screw backed out Constant locking torque keeps terminal screws in position Terminal screws are captive; cannot be lost in shipment or handling Hardened stainless steel clamping collar eliminates stripped threads Large opening in clamping collar accommodates oversized conductors; smallest collar will accept three 14 AWG stranded conductors Standards and Certifications 8 UL recognized: File No. E56797 CE approved 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 Volume 7--Logic Control, Operator Interface and Connectivity Solutions CA08100008E--November 2011 www.eaton.com V7-T8-111 8.2 Terminal Blocks, Fuse Blocks and Fuse Holders NEMA 8 Product Selection 8 TBA Modular Terminal Blocks 8 8 8 8 8 8 8 8 8 8 8 Rail and Base Mounted Terminal Blocks Description 8 8 Subminiature blocks 8 Ampacity (per Circuit) 1 Carton Quantity 2 Catalog Number Catalog Number (2) 14-12 12 5A 100 TBDSM12 4 TBDSM12 4 TBDV4 Miniature blocks 22-10 4 30A 100 TBDV4 Standard blocks--screw terminals with tang clamping collars 18-2 1 90A 100 -- TBDT1 22-8 2 40A 100 TBAT2 -- 22-8 3 40A 20 TBAT3-20 TBDT3-20 18-4 3 90A 100 TBDT70 TBDT70 High current blocks 14-2/0 3 175A 12 TBA100 5 -- Standard blocks--plug-in terminals 22-8 3 40A 20 TBAP -- 18-4 3 70A 20 TBAP70 -- 14-8 3 40A 20 TBAPL70 -- Panel mount blocks 22-10 3 30A 100 TBAL30 -- 8-4 3 115A 12 TBAL90 -- Disconnect blocks--for 1/4 in (6.4 mm) dia. by 1-1-7/16 in (25.4-36.5 mm) fuse 22-8 1 30A 50 TBAD -- Fuse blocks--for 13/32 in (10.3 mm) dia. by 1-1/2 in (38.1 mm) fuse 22-8 1 30A 50 TBDTF TBDTF 22-10 4 30A (600V) 90 TBBT4 -- 8 8 DIN Rail 3 Number of Poles Rail Mounted--600V 8 8 TBA Rail AWG Wire Size Base Mounted--600V 8 Miniature blocks--screw terminals with tang clamping collars 8 Standard blocks--standard screw terminals 22-8 3 40A 80 TBABT3 -- Universal mounting blocks 8 maximum 4 50A 6 25 TBU4 -- 8 maximum 6 50A 6 60 TBU6 -- 8 maximum 8 50A 6 45 TBU8 -- 8 maximum 12 50A 6 35 TBU12 -- 8 8 8 8 8 Notes 1 Based on 50C rise, test at 25C ambient while using maximum wire size. 2 Must be ordered in standard package quantity or in multiples of these quantities. 3 Dual mounting blocks--mount on either TMR/TBA rail or 35 mm DIN rail. 4 May also be mounted on mini-DIN rail (15 mm). Catalog Number C383TS15. 5 May also be base mounted. 6 TBU Series = 60A with crimped wire. 8 8 8 V7-T8-112 Volume 7--Logic Control, Operator Interface and Connectivity Solutions CA08100008E--November 2011 www.eaton.com Terminal Blocks, Fuse Blocks and Fuse Holders NEMA 8.2 Accessories 8 TB Series Terminal Blocks, Modular 8 Number of Poles Carton Quantity 2 Catalog Number 12.5 (317.5) -- 25 TMR12 37.5 (952.5) -- 25 TMR37 72.0 (1828.8) -- 25 TBATR72 1m -- 20 MC382MA1-20 Miniature blocks--TBDV4 and TBBT4 6.0 (152.4) -- 50 TMS6 TBU Series--matte finish 7.5 (190.5) -- 25 TMSU All other blocks 12.5 (317.5) -- 50 TMS 8 TBAT1 and TBAP70 -- 2-pole 100 TJ1 8 TBAT2 -- 2-pole 100 TJ2 TBAT3, TBABT3, TBAP and TBBP -- 2-pole 100 TJ3 Description Length 1 8 Mounting Rail Aluminum 35 mm DIN--steel 8 8 8 Marking Strips 8 Jumpers TBDV4 and TBBT4 -- 4-pole 100 TJ4 TBAD and TBATF -- 2-pole 100 TJ5 8 8 8 TBAL30 -- 2-pole 100 TJ6 TBU -- 12-pole 10 TJ7 TBDT3 -- 2-pole 100 TJ8 8 -- -- 50 TAD 8 Miscellaneous End piece for TBABT3 and TBBP Lug shield for TBA100 and TBAL90 -- -- 50 TAS Fuse puller -- -- 50 TBP Lighted fuse puller--blown fuse indication -- -- 25 TBLP 8 8 Notes 1 Length in inches (mm) except as noted. 2 Must be ordered in standard package quantity or in multiples of these quantities. 8 8 8 8 8 8 8 8 8 8 8 8 8 8 Volume 7--Logic Control, Operator Interface and Connectivity Solutions CA08100008E--November 2011 www.eaton.com V7-T8-113 8.2 8 8 Terminal Blocks, Fuse Blocks and Fuse Holders NEMA Technical Data and Specifications TB Series Terminal Blocks, Modular Description Specification 8 Continuous temperature 212F (100C) Tensile strength 10,000-12,000 psi 8 Impact resistance 2.0 ft-lb/in (arc) Arc resistance 140 seconds 8 8 8 8 8 8 Chemical resistance to: Acetone Ammonia gas Benzene Gasoline Mineral oil Sodium bisulfate Sodium chloride Sodium nitrate Water up to 50C Flashover Voltages Catalog Number Vac rms, 60 Hz Recommended Terminal Tightening Torque Opposite Polarity To Ground Wire Size Torque 20 lb-in TBAT1 9100 6600 Up to 8 AWG TBAT2 9600 7300 Up to 4 AWG 35 lb-in TBAT3 8600 7300 Up to 2/0 AWG 50 lb-in 8 8 8 8 8 8 8 To find a current rating, place a straight edge horizontally at the value of anticipated maximum internal panel ambient (scale on the left), and read the current rating for the device on the bottom scale. Example: at 60C, TBAT3 is rated 54 amperes. 8 8 8 Ambient Temp. in C 8 80 10 70 20 30 60 TBAT2 TBAL100 TBAT3 50 40 TBAT1 TBAL30 40 TBAL90 50 TBAP TBAM4 30 20 40 Temp. Rise in C 8 Ratings based on 90C total temperature of a three-pole block with each pole carrying current and wired with largest size conductors. Temperature Rating 8 8 Ampere rating is based on maximum allowable temperature--ambient temperature plus temperature rise due to current. TBAB70 60 80 100 120 140 160 Current in Amps 180 200 220 240 60 8 8 8 8 8 8 V7-T8-114 Volume 7--Logic Control, Operator Interface and Connectivity Solutions CA08100008E--November 2011 www.eaton.com 8.2 Terminal Blocks, Fuse Blocks and Fuse Holders NEMA Dimensions Approximate Dimensions in Inches (mm) 8 TB Series Terminal Blocks, Modular 8 1.09 (27.7) 0.88 (22.4) 1.88 (47.8) 0.63 (16) 1.23 (31.2) 8 0.63 (16) 0.17 - 0.28 (4.3 - 7.1) Clearance for #8 Screw TBDSM12 3 Holes 0.09 (2.3) Dia. 0.33 (8.4) Deep 0.67 0.59 (17) (15) 1.23 (31.2) 0.59 (15) 1.48 (37.6) 1.71 (43.4) 1 (25.4) 1.25 (31.8) 1.25 (31.8) 8 TBBT4 8 1.88 (47.8) 1/4-28 Screw 8 1.19 (30.2) 1.75 (44.5) TBDV4 8 TBDT1 1.53 (38.9) 0.63 (16) 1.25 (31.8) 1.23 (31.2) #6-32 Screw 1.25 (31.8) 0.17 - 0.27 (4.3 - 6.9) Clearance for #8 Screw Footlock Cat. #TAD 1.25 (31.8) 3.13 (79.5) TBAL90 1.69 (42.9) 2.47 (62.7) TBABT3 0.31 (7.9) TBAL30 0.66 (16.8) 0.25 (6.4) TBAT3 & TBDT3 3.13 (79.5) 12.5 - 37.5 (317.5 - 952.5) 8 8 0.25 (6.4) TMR12 & TMR37 1.25 (31.8) 0.63 (16) 8 8 1.25 (31.8) #10 Screw Clearance 0.59 (15) 1.31 (33.3) 1.53 (38.9) 1.86 (47.2) 1.75 (44.5) 0.63 (16) 1.34 (34) TBDT70 8 1.77 (45) 1.94 (49.3) 0.47 (11.9) 1.88 (47.8) 8 1.25 (31.8) TBAP 2 (50.8) 1.5 (38.1) 0.63 (16) 0.44 (11.2) 2 (50.8) 1.25 (31.8) 0.63 (16) TBAD & TBDTF (127) 6.25 TBU8 (158.8) 8.75 TBU12 (222.3) Volume 7--Logic Control, Operator Interface and Connectivity Solutions CA08100008E--November 2011 www.eaton.com 8 8 8 #10 Screw A B Clearance 3.75 2.87 TBU4 (95.3) (72.9) 0.5 5 4.12 (12.7) TBU6 A TBU4, TBU6, TBU8 & TBU12 8 8 0.13 (3.3) 0.63 (16) 72 (1828.8) TBATR72 0.56 (14.2) B 0.63 (16) 1.25 (31.8) TBA100 8 8 0.19 (4.8) 1.3 (33) TBAT2 8 8 1.33 (33.8) 1.25 (31.8) 1.3 (33) 8 8 1.86 (47.2) 1.78 (45.2) 0.63 (16) 1.3 (33) 8 8 1.25 (31.8) TBAP70 & TBAPL70 1.25 (31.8) 8 1.38 (35.1) 1 (25.4) 2 (50.8) 2.4 (61) 8 (104.6) 5.37 (136.4) 7.87 (199.9) 8 8 V7-T8-115 8.3 8 Terminal Blocks, Fuse Blocks and Fuse Holders Power Distribution Contents Power Distribution Products Description 8 Page Power Distribution CHDB Series--Power Distribution Blocks . . . . CH160 Series--Power Terminal Blocks . . . . . . Power Terminal Block Accessories . . . . . . . . . . 8 8 8 8 8 8 8 8 8 Power Distribution Overview 8 Product Selection Guide Series Current Range UL Certification High Short UL 508A Approved for Industrial Control Panels Circuit Current 1 Rating Branch Circuits Feeder Circuits CH162 115-175A UL 1059 Recognized No Yes No 2 Yes 8 CH163 175-420A UL 1059 Recognized No Yes No 2 Yes CH165 620-840A UL 1059 Recognized No Yes No 2 Yes 8 CHDB 175-570A UL 1953 Listed Yes Yes Yes Yes 8 8 8 8 HVAC UL 1995 Notes 1 Refer to Page V7-T8-118 to determine short circuit current ratings with fuses and Pages V7-T8-119 and V7-T8-120 to determine short circuit current ratings in conjunction with specific Eaton circuit breakers. 2 Single-pole units, when installed with proper spacings, may meet requirements for UL 508A feeder circuits. 8 8 8 8 8 8 8 8 8 8 8 8 V7-T8-116 Volume 7--Logic Control, Operator Interface and Connectivity Solutions CA08100008E--November 2011 www.eaton.com V7-T8-117 V7-T8-123 V7-T8-126 Terminal Blocks, Fuse Blocks and Fuse Holders Power Distribution CHDB Series--Power Distribution Blocks, Enclosed and Open 8.3 Contents Description Page CHDB Series--Power Distribution Blocks Product Selection . . . . . . . . . . . . . . . . . . . . . . . Technical Data and Specifications . . . . . . . . . . Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . CH160 Series--Power Terminal Blocks . . . . . . . . . Power Terminal Block Accessories . . . . . . . . . . . . 8 8 V7-T8-118 V7-T8-118 V7-T8-121 V7-T8-123 V7-T8-126 8 8 8 8 8 8 8 8 8 CHDB Series--Power Distribution Blocks Product Description Eaton's CHDB Series of Power Distribution Blocks was designed for high short circuit current rating (SCCR) applications up to 200,000 amperes. They are assembled with the minimum spacing to meet UL 1953 requirements for feeder circuits in UL 508A industrial control panels, and provide significant wiring flexibility. Available in three-pole open style and single-pole enclosed style with a variety of terminal arrangements and current-carrying capability up to 570 amperes. Features and Benefits Enclosed Style IP20 finger-safe enclosure 600 Vac or Vdc (UL 1953), 690 Vac or Vdc DIN rail or panel mount Captive termination screws prevent lost screws Single-pole, gang mountable for multi-pole applications Tin plated Al connections suitable for Cu conductors Flammability, UL 94V-0 Standards and Certifications Open Style 600 Vac or Vdc (UL 1953) Panel mount Three-pole open design for easy wiring Tin-plated Al connections suitable for Cu conductors Flammability, UL 94V-0 Available covers for additional protection (does not meet IP20) UL Listed 1953, Guide QPQS, File E256146 CSA Certified, Class 6228-01, File 15364 (enclosed style) CE Component IEC 60947-7-1 (enclosed style) IEC 60529, IP20 (fingersafe) under specific wiring conditions (enclosed style) 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 Volume 7--Logic Control, Operator Interface and Connectivity Solutions CA08100008E--November 2011 www.eaton.com V7-T8-117 8.3 8 Terminal Blocks, Fuse Blocks and Fuse Holders Power Distribution Product Selection 8 CHDB Series--Power Distribution Blocks 8 Line Connection Load Connection 2/0-#8 AWG Amperes Style Poles Catalog Number (4) #4-#14 AWG 175 Open 3 CHDB2203 2/0-#8 AWG (6) #4-#14 AWG 175 Open 3 CHDB3213 8 300 kcmil-#4 AWG (6) #4-#12 AWG 310 Open 3 CHDB3233 8 300 kcmil-#4 AWG (12) #4-#14 AWG 310 Open 3 CHDB3703 8 300 kcmil-#4 AWG CHDB2203 (Open) Configuration 8 8 8 CHDB204F (Enclosed) (6) #2-#12 AWG 310 Open 3 CHDB3713 (3) 1/0-#12 AWG 310 Open 3 CHDB3713 1 CHDB204F 2/0-#8 AWG 2/0-#8 AWG 175 Enclosed 1 500 kcmil-#6 AWG (6) #2-#14 AWG 380 Enclosed 1 1 CHDB330F 300 kcmil-#4 AWG (12) #4-#14 AWG 570 Enclosed 1 1 CHDB377F 8 8 8 8 8 Technical Data and Specifications 8 Power Terminal Block Short-Circuit Current Ratings (SCCR) with Fuses 8 8 Catalog Number Terminal Copper Conductors Line Load CHDB2203 2/0-#8 AWG 8 8 8 CHDB3213 CHDB3233 2/0-#8 AWG 300 kcmil-#4 AWG 8 8 CHDB3703 300 kcmil-#4 AWG 8 8 8 8 CHDB3713 300 kcmil-#4 AWG SCCR (kA) #4-#12 AWG 200 200 200 60 200 175 175 100 60 100 200 200 100 60 50 400 400 200 100 200 400 400 400 100 100 #4-#14 AWG 175 175 100 60 100 #4-#8 AWG 400 400 200 100 200 400 400 400 100 100 #4-#12 AWG 175 175 100 60 100 #4-#8 AWG 400 400 200 100 200 #4-#14 AWG 400 400 400 100 100 100 #4-#12 AWG 175 175 100 60 1/0-#6 AWG 400 400 200 100 200 #4-#12 AWG 400 400 400 100 100 175 175 100 60 100 CHDB204F 2/0-#8 AWG 2/0-#8 AWG 200 200 100 60 200 CHDB330F 500 kcmil-#6 AWG #2-#6 AWG 400 400 200 100 200 #2-#14 AWG 200 200 100 30 50 175 175 100 30 100 300 kcmil #4-#8 AWG 600 600 400 200 200 300 kcmil-#4 AWG #4 AWG 600 600 400 200 50 #4-#14 AWG 200 200 100 30 50 CHDB377F 8 8 RK-5 FRS-R/FRN-R #4-#14 AWG 8 8 Maximum Fuse Class and Amperes J T RK-1 LPJ JJS/JJN LPS-RK/LPN-RK Note 1 Finger-safe. V7-T8-118 Volume 7--Logic Control, Operator Interface and Connectivity Solutions CA08100008E--November 2011 www.eaton.com Terminal Blocks, Fuse Blocks and Fuse Holders Power Distribution 8.3 Power Terminal Block Short-Circuit Ratings (SCCR) for UL 508A Applications with Circuit Breakers Opening per Pole 8 Line Conductors Cu Load Conductors Cu SCCR @ 480V (Load Side) Eaton Breaker Available Breaker Current Ratings 8 175 2/0-#8 #4-#10 #12 #14 18 kA 18 kA 14 kA EGB125 15, 20, 25, 30, 35, 40, 45, 50, 60, 70, 80, 90, 100, 125 8 16.00 x 16.00 x 6.75 (406.4 x 406.4 x 171.5) 175 2/0-#8 #4-#10 #12 #14 25 kA 22 kA 14 kA EGE125 15, 20, 25, 30, 35, 40, 45, 50, 60, 70, 80, 90, 100, 125 Feeder Listed Open PDB 16.00 x 16.00 x 6.75 (406.4 x 406.4 x 171.5) 175 2/0-#8 #4-#10 #12 #14 50 kA 22 kA 14 kA EGS125 15, 20, 25, 30, 35, 40, 45, 50, 60, 70, 80, 90, 100, 125 CHDB2203 Feeder Listed Open PDB 16.00 x 16.00 x 6.75 (406.4 x 406.4 x 171.5) 175 2/0-#8 #4-#10 #12 #14 65 kA 22 kA 14 kA EGH125 15, 20, 25, 30, 35, 40, 45, 50, 60, 70, 80, 90, 100, 125 CHDB2203 Feeder Listed Open PDB 16.00 x 16.00 x 6.75 (406.4 x 406.4 x 171.5) 175 2/0-#8 #4-#10 #12 #14 65 kA 22 kA 14 kA EGC125 1 15, 20, 25, 30, 35, 40, 45, 50, 60, 70, 80, 90, 100, 125 CHDB3213 Feeder Listed Open PDB 24.00 x 20.00 x 6.75 (609.6 x 508.0 x 171.5) 175 2/0-#8 #4-#10 #12 #14 18 kA 18 kA 18 kA EGB125 15, 20, 25, 30, 35, 40, 45, 50, 60, 70, 80, 90, 100, 125 CHDB3213 Feeder Listed Open PDB 24.00 x 20.00 x 6.75 (609.6 x 508.0 x 171.5) 175 2/0-#8 #4-#10 #12 #14 25 kA 22 kA 18 kA EGE125 15, 20, 25, 30, 35, 40, 45, 50, 60, 70, 80, 90, 100, 125 CHDB3213 Feeder Listed Open PDB 24.00 x 20.00 x 6.75 (609.6 x 508.0 x 171.5) 175 2/0-#8 #4-#10 #12 #14 50 kA 22 kA 18 kA EGS125 15, 20, 25, 30, 35, 40, 45, 50, 60, 70, 80, 90, 100, 125 CHDB3213 Feeder Listed Open PDB 24.00 x 20.00 x 6.75 (609.6 x 508.0 x 171.5) 175 2/0-#8 #4-#10 #12 #14 65 kA 22 kA 18 kA EGH125 15, 20, 25, 30, 35, 40, 45, 50, 60, 70, 80, 90, 100, 125 CHDB3213 Feeder Listed Open PDB 24.00 x 20.00 x 6.75 (609.6 x 508.0 x 171.5) 175 2/0-#8 #4-#10 #12 #14 65 kA 22 kA 18 kA EGC125 1 15, 20, 25, 30, 35, 40, 45, 50, 60, 70, 80, 90, 100, 125 CHDB204F Feeder Listed Enclosed PDB 16.00 x 16.00 x 6.75 (406.4 x 406.4 x 171.5) 175 2/0-#8 2/0-#8 18 kA EGB125 15, 20, 25, 30, 35, 40, 45, 50, 60, 70, 80, 90, 100, 125 CHDB204F Feeder Listed Enclosed PDB 16.00 x 16.00 x 6.75 (406.4 x 406.4 x 171.5) 175 2/0-#8 2/0-#8 25 kA EGE125 15, 20, 25, 30, 35, 40, 45, 50, 60, 70, 80, 90, 100, 125 CHDB204F Feeder Listed Enclosed PDB 16.00 x 16.00 x 6.75 (406.4 x 406.4 x 171.5) 175 2/0-#8 2/0-#8 35 kA EGS125 15, 20, 25, 30, 35, 40, 45, 50, 60, 70, 80, 90, 100, 125 CHDB204F Feeder Listed Enclosed PDB 16.00 x 16.00 x 6.75 (406.4 x 406.4 x 171.5) 175 2/0-#8 2/0-#8 65 kA EGH125 15, 20, 25, 30, 35, 40, 45, 50, 60, 70, 80, 90, 100, 125 CHDB204F Feeder Listed Enclosed PDB 16.00 x 16.00 x 6.75 (406.4 x 406.4 x 171.5) 175 2/0-#8 2/0-#8 65 kA EGC125 1 15, 20, 25, 30, 35, 40, 45, 50, 60, 70, 80, 90, 100, 125 CHDB3233 Feeder Listed Open PDB 24.00 x 20.00 x 6.75 (609.6 x 508.0 x 171.5) 310 350 kmil-#4 #4-#6 #8 #10 25 kA 25 kA 14 kA JGE250 70, 90, 100, 125, 150, 175, 200, 225, 250 CHDB3233 Feeder Listed Open PDB 24.00 x 20.00 x 6.75 (609.6 x 508.0 x 171.5) 310 350 kmil-#4 #4-#6 #8 #10 35 kA 35 kA 14 kA JGS250 70, 90, 100, 125, 150, 175, 200, 225, 250 CHDB3233 Feeder Listed Open PDB 24.00 x 20.00 x 6.75 (609.6 x 508.0 x 171.5) 310 350 kmil-#4 #4-#6 #8 #10 65 kA 42 kA 14 kA JGH250 70, 90, 100, 125, 150, 175, 200, 225, 250 CHDB3233 Feeder Listed Open PDB 24.00 x 20.00 x 6.75 (609.6 x 508.0 x 171.5) 310 350 kmil-#4 #4-#6 #8 #10 65 kA 42 kA 25 kA JGC250 1 70, 90, 100, 125, 150, 175, 200, 225, 250 Catalog Number Description Enclosure Size in Inches (mm) Current Rating CHDB2203 Feeder Listed Open PDB 16.00 x 16.00 x 6.75 (406.4 x 406.4 x 171.5) CHDB2203 Feeder Listed Open PDB CHDB2203 Line Load 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 Note 1 This breaker frame is marked current limiting and suitable for use as current limiting per UL 508A SB.4.3.2. 8 8 Volume 7--Logic Control, Operator Interface and Connectivity Solutions CA08100008E--November 2011 www.eaton.com V7-T8-119 8.3 8 8 8 8 8 8 8 Line Conductors Cu Load Conductors Cu SCCR at 480V (Load Side) Eaton Breaker Available Breaker Current Ratings 310 350 kmil-#4 #4-#6 #8 #10 25 kA 25 kA 14 kA JGE250 70, 90, 100, 125, 150, 175, 200, 225, 250 24.00 x 20.00 x 6.75 (609.6 x 508.0 x 171.5) 310 350 kmil-#4 #4-#6 #8 #10 35 kA 35 kA 14 kA JGS250 70, 90, 100, 125, 150, 175, 200, 225, 250 Feeder Listed Open PDB 24.00 x 20.00 x 6.75 (609.6 x 508.0 x 171.5) 310 350 kmil-#4 #4-#6 #8 #10 65 kA 42 kA 14 kA JGH250 70, 90, 100, 125, 150, 175, 200, 225, 250 CHDB3703 Feeder Listed Open PDB 24.00 x 20.00 x 6.75 (609.6 x 508.0 x 171.5) 310 350 kmil-#4 #4-#6 #8 #10 65 kA 42 kA 25 kA JGC250 1 70, 90, 100, 125, 150, 175, 200, 225, 250 CHDB3713 Feeder Listed Open PDB 24.00 x 20.00 x 6.75 (609.6 x 508.0 x 171.5) 310 350 kmil-#4 #4-#6 #8 #10 25 kA 25 kA 14 kA JGE250 70, 90, 100, 125, 150, 175, 200, 225, 250 CHDB3713 Feeder Listed Open PDB 24.00 x 20.00 x 6.75 (609.6 x 508.0 x 171.5) 310 350 kmil-#4 #4-#6 #8 #10 35 kA 35 kA 14 kA JGS250 70, 90, 100, 125, 150, 175, 200, 225, 250 CHDB3713 Feeder Listed Open PDB 24.00 x 20.00 x 6.75 (609.6 x 508.0 x 171.5) 310 350 kmil-#4 #4-#6 #8 #10 50 kA 42 kA 14 kA JGH250 70, 90, 100, 125, 150, 175, 200, 225, 250 CHDB3713 Feeder Listed Open PDB 24.00 x 20.00 x 6.75 (609.6 x 508.0 x 171.5) 310 350 kmil-#4 #4-#6 #8 #10 65 kA 50 kA 25 kA JGC250 1 70, 90, 100, 125, 150, 175, 200, 225, 250 CHDB330F Feeder Listed Enclosed PDB 24.00 x 20.00 x 6.75 (609.6 x 508.0 x 171.5) 380 500 kmil-#3 #2-#8 14 kA LGE400 250, 300, 350, 400 CHDB330F Feeder Listed Enclosed PDB 24.00 x 20.00 x 6.75 (609.6 x 508.0 x 171.5) 380 500 kmil-#3 #2-#8 14 kA LGS400 250, 300, 350, 400 CHDB330F Feeder Listed Enclosed PDB 24.00 x 20.00 x 6.75 (609.6 x 508.0 x 171.5) 380 500 kmil-#3 #2-#8 14 kA LGH400 250, 300, 350, 400 CHDB330F Feeder Listed Enclosed PDB 24.00 x 20.00 x 6.75 (609.6 x 508.0 x 171.5) 380 500 kmil-#3 #2-#8 25 kA LGC400 1 250, 300, 350, 400 CHDB377F Feeder Listed Enclosed PDB 24.00 x 20.00 x 6.75 (609.6 x 508.0 x 171.5) 570 (2) 300 kmil-#2 #4 #6 #8 30 kA 18 kA 14 kA LGE600 250, 300, 350, 400, 500, 600 CHDB377F Feeder Listed Enclosed PDB 24.00 x 20.00 x 6.75 (609.6 x 508.0 x 171.5) 570 (2) 300 kmil-#2 #4 #6 #8 30 kA 18 kA 14 kA LGS600 250, 300, 350, 400, 500, 600 CHDB377F Feeder Listed Enclosed PDB 24.00 x 20.00 x 6.75 (609.6 x 508.0 x 171.5) 570 (2) 300 kmil-#2 #4 #6 #8 30 kA 18 kA 14 kA LGH600 250, 300, 350, 400, 500, 600 CHDB377F Feeder Listed Enclosed PDB 24.00 x 20.00 x 6.75 (609.6 x 508.0 x 171.5) 570 (2) 300 kmil-#2 #4 #6 #8 42 kA 35 kA 14 kA LGC600 1 250, 300, 350, 400, 500, 600 Opening per Pole Catalog Number Description Enclosure Size in Inches (mm) Current Rating CHDB3703 Feeder Listed Open PDB 24.00 x 20.00 x 6.75 (609.6 x 508.0 x 171.5) CHDB3703 Feeder Listed Open PDB CHDB3703 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 Power Distribution Power Terminal Block Short-Circuit Ratings (SCCR) for UL 508A Applications with Circuit Breakers, continued 8 8 Terminal Blocks, Fuse Blocks and Fuse Holders Line Load Note 1 This breaker frame is marked current limiting and suitable for use as current limiting per UL 508A SB.4.3.2. 8 8 8 8 8 8 V7-T8-120 Volume 7--Logic Control, Operator Interface and Connectivity Solutions CA08100008E--November 2011 www.eaton.com 8.3 Terminal Blocks, Fuse Blocks and Fuse Holders Power Distribution Dimensions 8 Approximate Dimensions in Inches (mm) CHDB2203 8 CHDB3713 4.25 (108.0) 2.13 (54.1) 11 12 11 6.30 (160.0) 3.70 (94.0) 12 11 8 8 12 8 2.88 (73.2) 5.50 (139.7) 21 22 21 22 21 8 8 22 8 8 CHDB204F CHDB3213 5.19 (131.8) 3.32 (84.3) 8 Load Side 1.03 (26.2) Line Side 8 2.92 (74.2) 4.00 (101.6) 8 8 3.73 (94.7) 8 8 8 CHDB3233 3.70 (94.0) 6.30 (160.0) 8 2.15 (54.6) 8 8 1.40 (35.6) 5.50 (139.7) 8 3.55 (90.2) 8 8 8 CHDB3703 8 6.30 (160.0) 3.70 (94.0) 8 8 8 5.50 (139.7) 8 8 8 Volume 7--Logic Control, Operator Interface and Connectivity Solutions CA08100008E--November 2011 www.eaton.com V7-T8-121 8.3 8 Terminal Blocks, Fuse Blocks and Fuse Holders Power Distribution Approximate Dimensions in Inches (mm) CHDB330F CHDB377F 8 8 Load Side 1.54 Line (39.1) Side 8 8 3.82 (97.0) 8 4.66 (118.4) Load Side 1.86 (47.2) 3.82 (97.0) 4.66 (118.4) 8 8 8 8 2.87 (72.9) 2.93 (74.4) 8 8 8 1.40 (35.6) 4.49 (114.0) 8 1.40 (35.6) 4.49 (114.0) 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 V7-T8-122 Volume 7--Logic Control, Operator Interface and Connectivity Solutions CA08100008E--November 2011 www.eaton.com Line Side Terminal Blocks, Fuse Blocks and Fuse Holders Power Distribution 8.3 Contents CH160 Series--Power Terminal Blocks Description CHDB Series--Power Distribution Blocks . . . . . . . CH160 Series--Power Terminal Blocks Product Selection . . . . . . . . . . . . . . . . . . . . . . . Technical Data and Specifications . . . . . . . . . . Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . Power Terminal Block Accessories . . . . . . . . . . . . Page V7-T8-117 V7-T8-124 V7-T8-125 V7-T8-125 V7-T8-126 8 8 8 8 8 8 8 8 8 8 8 CH160 Series--Power Terminal Blocks Product Description Features and Benefits The CH160 Series of Power Terminal Blocks are UL 1059 recognized power terminal blocks for branch circuit applications. All short circuit current ratings (SCCR) are 10 kA per UL 508A Table SB4.1. The blocks are available in a wide variety of wiring configurations, providing excellent flexibility. Ratings: To 840A, 600V Materials Molded material; black, UL rated 94V-0 thermoplastic Operating temperature: 302F (150C) Optional cover: See Page V7-T8-125 8 Standards and Certifications UL Recognized CSA Certified 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 Volume 7--Logic Control, Operator Interface and Connectivity Solutions CA08100008E--November 2011 www.eaton.com V7-T8-123 8.3 8 8 8 8 8 Terminal Blocks, Fuse Blocks and Fuse Holders Power Distribution Product Selection When Ordering, Specify Catalog number Number of poles (up to three-pole available) CH160 Power Terminal Blocks--CH162 Series Line Connection Load Connection Connector Material and Ampacity Catalog Number 1 #2-#14 Cu/#8 Al #2-#14 Cu/#8 Al Al 115A CH16200_ 8 1/0-#14 Cu 1/0-#14 Cu Cu 150A CH16201_ 2/0-#8 Cu/Al 2/0-#8 Cu/Al Al 175A CH16204_ 8 2/0-#14 Cu/#8 Al (4) #4-#14 Cu/#8 Al Al 175A CH16220_ 8 8 CH160 Power Terminal Blocks--CH163 Series Line Connection Load Connection Connector Material and Ampacity Catalog Number 1 250 kcmil-#6 Cu 250 kcmil-#6 Cu Cu 255A CH16301_ 350 kcmil-#6 Cu/Al 350 kcmil-#6 Cu/Al Al 310A CH16303_ 500 kcmil-#6 Cu/Al 500 kcmil-#6 Cu/Al Al 380A CH16306_ 8 2/0-#14 Cu/Al (6) #4-#14 Cu/#8 Al Al 175A CH16321_ 350 kcmil-#6 Cu/Al (6) #4-#14 Cu/#8 Al Al 310A CH16323_ 8 (2) 2/0-#14 Cu/#8 Al (6) #4-#14 Cu/#8 Al Al 350A CH16325_ 500 kcmil-#6 Cu/Al (6) #2-#14 Cu/#8 Al Al 380A CH16330_ 350 kcmil-#6 Cu/Al (3) #2-#14 Cu/#8 Al Al 310A CH16332_ 8 8 8 (2) 1/0-#14 Cu/#8 Al Al 310A CH16332_ 350 kcmil-#6 Cu/Al (12) #4-#14 Cu/#8 Al Al 310A CH16370_ 8 350 kcmil-#6 Cu/Al (6) #2-#14 Cu/#8 Al Al 310A CH16371_ (3) 1/0-#14 Cu/#8 Al Al 310A CH16371_ 8 350 kcmil-#6 Cu/Al (21) #10-#14 Cu/#10 Al Al 310A CH16372_ 350 kcmil-#6 Cu/Al (3) 1/0-#14 Cu/#8 Al Al 310A CH16373_ (14) #10-#14 Cu/#8 Al Al 310A CH16373_ (12) #4-#14 Cu/#8 Al Al 420A CH16375_ (6) #2-#14 Cu/#8 Al Al 420A CH16376_ (3) 1/0-#14 Cu/#8 Al Al 420A CH16376_ 8 8 8 600 kcmil-#2 Cu/Al 600 kcmil-#2 Cu/Al 8 8 8 8 8 8 8 8 CH160 Power Terminal Blocks--CH165 Series Line Connection Load Connection Connector Material and Ampacity Catalog Number 1 (2) 350 kcmil-4 Cu/Al (2) 350 kcmil-4 Cu/Al Al 620A CH16500_ (2) 500 kcmil-#6 Cu/Al (2) 500 kcmil-#6 Cu/Al Al 760A CH16504_ (2) 600 kcmil-#2 Cu/Al (2) 500 kcmil-#6 Cu/Al (4) 3/0-#8 Cu/Al Al 840A CH16528_ (4) #4-#14 Cu/#8 Al Al 840A CH16528_ (12) #4-#14 Cu/#8 Al Al 760A CH16530_ Note 1 Incomplete catalog number--add code suffix -1, -2, -3 for number of poles. Example: For a 150A 1/0-#14 Cu to 1/0-#14 Cu three-pole PDB, order CH16201-3. 8 8 8 V7-T8-124 Volume 7--Logic Control, Operator Interface and Connectivity Solutions CA08100008E--November 2011 www.eaton.com 8.3 Terminal Blocks, Fuse Blocks and Fuse Holders Power Distribution Technical Data and Specifications 8 CH160 Power Terminal Blocks Description 8 Specification Ratings To 840A, 600V Materials Molded material; black, UL rated 94V-0 thermoplastic Operating temperature 302F (150C) 8 8 Note: For optional cover, see Power Terminal Block Accessories, Page V7-T8-126. 8 8 Dimensions 8 Approximate Dimensions in Inches (mm) Series CH163 (Single-, Two- and Three-Pole Available) Series CH162 and CH165 (Single-, Two- and Three-Pole Available) A 8 A D G B B G F F E E C 8 D H 8 8 8 C E E 8 8 0.20 (5.1) Dia. Hole with 0.40 (10.2) C'Bore J Mtg. Holes 0.21 x 0.41 (5.3 x 10.4) C'Bore 0.42 x 0.62 x 0.12 Deep (10.7 x 15.7 x 3.0 Deep) J 8 8 CH160 Power Terminal Block Dimensions C C 8 C Series A B Single-Pole Two-Pole Three-Pole D E4 F G H J CH162 2.87 (72.9) 2.25 (57.2) 1.06 (26.9) 1.87 (47.5) 2.68 (68.1) 1.75 (44.5) 0.81 (20.6) 0.53 (13.5) 0.31 (7.9) 0.84 (21.3) 0.31 (7.9) CH163 4.00 (101.6) 3.37 (85.6) 1.96 (49.8) 3.58 (90.9) 5.20 (132.1) 3.32 (84.3) 1.62 (41.1) 0.97 (24.6) 0.31 (7.9) 0.87 (22.1) 0.35 (8.9) CH165 5.50 (139.7) 4.75 (120.7) 3.12 (79.2) 5.81 (147.6) 8.50 (215.9) 3.12 (79.2) 2.68 (68.1) 1.56 (39.6) 0.37 (9.4) 1.37 (34.8) 0.62 (15.7) 8 8 8 8 8 8 8 8 8 8 8 8 8 Volume 7--Logic Control, Operator Interface and Connectivity Solutions CA08100008E--November 2011 www.eaton.com V7-T8-125 8.3 8 Terminal Blocks, Fuse Blocks and Fuse Holders Power Distribution Contents Power Terminal Block Accessories Description 8 CHDB Series--Power Distribution Blocks . . . . . . . CH160 Series--Power Terminal Blocks . . . . . . . . . Power Terminal Block Accessories Technical Data and Specifications . . . . . . . . . . Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 8 8 8 8 8 8 8 8 Power Terminal Block Accessories 8 Product Description Standards and Certifications 8 Protective Cover Guards against accidental contact Clear with write-on surface for field termination identification Available in single-, twoand three-pole TB Series Power Blocks Contact Eaton for the latest UL 508A short circuit ratings on terminal blocks UL Recognized: File No. E62622 CSA Certified: File No. LR15364 8 8 8 8 8 8 Product Selection 8 When Ordering, Specify Catalog number 8 CH163 Series Cover 8 Description Catalog Number Single-pole cover CHCPDB-1 1 Two-pole cover CHCPDB-2 1 8 Three-pole cover CHCPDB-3 1 8 TB Series Power Blocks 8 8 8 Line Connection Load Connection Catalog Number #300 kcmil-#6 Cu/Al (6) #6-#14 Cu/#8Al TBAN63 Note 1 Standard pack, five pieces. 8 8 8 V7-T8-126 Volume 7--Logic Control, Operator Interface and Connectivity Solutions CA08100008E--November 2011 www.eaton.com Page V7-T8-117 V7-T8-123 V7-T8-127 V7-T8-127 Terminal Blocks, Fuse Blocks and Fuse Holders Power Distribution 8.3 Technical Data and Specifications 8 TB Series Power Blocks Description 8 Specification Ratings 285A, 600V; UL/CSA Materials Molded material; black, UL rated 94V-2 thermoplastic Operating temperature 257F (125C) 8 8 8 Dimensions 8 Approximate Dimensions in Inches (mm) CH163 Series Cover 8 Supplied with (4) #4 Thread-Cutting Screws Assembled as Shown 8 8 8 8 4.14 (105.2) 8 8 CHCPDB-1 = 2.1 (53.3) CHCPDB-2 = 3.72 (94.5) CHCPDB-3 = 5.34 (135.6) 8 8 Textured Surfaces 8 TB Series Power Blocks 4.93 (125.2) 8 1.68 (42.7) 8 0.5 (12.7) 8 8 2.12 (53.8) 0.2 x 0.37 (5.1 x 9.4) Mtg. Slot 8 8 5.37 (136.4) 8 8 8 8 8 8 8 8 Volume 7--Logic Control, Operator Interface and Connectivity Solutions CA08100008E--November 2011 www.eaton.com V7-T8-127 8.4 8 Terminal Blocks, Fuse Blocks and Fuse Holders Fuse Blocks and Fuse Holders Contents Fuse Blocks and Fuse Holders Description 8 Fuse Blocks and Fuse Holders C383 Series Disconnect Fuse Holders . . . . . . . C350 Series Fuse Blocks and W Series Fuse Holders. . . . . . . . . . . . . . . . . . 8 8 8 8 8 8 8 8 8 Fuse Blocks and Fuse Holders Overview 8 Product Description Application Description Standards and Certifications Available in compact finger safe (C383) and an open (C350) design. Eaton's fuse blocks and holders provide a simple DIN mounting device for protection in control circuits. Fuse holders and blocks available for Class CC, midget, H, M and R. 8 8 8 UL listed CSA certified (may not apply to all styles) 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 V7-T8-128 Volume 7--Logic Control, Operator Interface and Connectivity Solutions CA08100008E--November 2011 www.eaton.com Page V7-T8-129 V7-T8-131 Terminal Blocks, Fuse Blocks and Fuse Holders Fuse Blocks and Fuse Holders 8.4 Contents C383 Series Fuse Holders Description Page C383 Series Disconnect Fuse Holders Product Selection . . . . . . . . . . . . . . . . . . . . . . . Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . Technical Data and Specifications . . . . . . . . . . Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . C350 Series Fuse Blocks and W Series Fuse Holders . . . . . . . . . . . . . . . . . . . . 8 8 V7-T8-130 V7-T8-130 V7-T8-130 V7-T8-130 V7-T8-131 8 8 8 8 8 8 8 8 8 C383 Series Disconnect Fuse Holders Product Description Features Eaton's C383 Series disconnect fuse holders offer 600V fused circuit protection and subsequently "no load" switching. These compact disconnects are designed as components in switchboards, panels and control consoles where positive and safe circuit protection is required and where space is at a premium. The C383 fuse holders mount directly on standard TS35 DIN rails. "Finger-Safe" design-- Recessed termination screws and a fuse extraction door afford you IP20 grade protection and qualify as "finger-safe" per IEC standards Easy to adjust position on rail--Simply unlatch the DIN rail adapter, slide the holder to desired position and relock Quick change of fuse-- A permanently attached pivoting fuse door simplifies and speeds fuse extraction. No tools or accessories needed Standards and Certifications Class CC model is UL listed and CSA certified for branch circuit protection. Midget models are UL Recognized and CSA certified for supplementary and high-speed protection Runs cool--The vented design provides adequate air flow around the holders at all times Self-extinguishing UL 94-VO rated polyester material Rated voltage: CSA/UL: 600 Vac/Vdc, 30A IEC (midget only): 690 Vac, 32A 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 Volume 7--Logic Control, Operator Interface and Connectivity Solutions CA08100008E--November 2011 www.eaton.com V7-T8-129 8.4 8 8 Terminal Blocks, Fuse Blocks and Fuse Holders Fuse Blocks and Fuse Holders Product Selection Disconnect Fuse Holders C383FH_ Description Standard Pack Catalog Number 12 C383FHCC 12 C383FHMD Standard Pack Catalog Number For Class CC Fuse 8 Single-pole fuse holder For Midget Fuse (1-1/2 in x 13/32 in) 8 Single-pole fuse holder 8 8 8 Accessories Disconnect Fuse Holders Description 8 Midget or Class CC Fuse Holder Multi-pole connection links 100 C383MPCL 8 Multi-pole handle pins 100 C383MPHP 8 Accessory Details 8 8 8 C383MPCL Multi-pole connection links can be used to connect fuse holders together for multipole applications. Use two per connection. C383MPHP Handle pins can be used to connect handles in multi-pole applications. 8 Technical Data and Specifications 8 Disconnect Fuse Holders 1 8 8 8 Description Specification Housing Polyester UL 94-VO rated Color White Wire size 8-18 AWG 2 Torque 22 lb-in (2.5 Nm) Fuse size 0.41 x 1.5 in 8 8 8 Dimensions Approximate Dimensions in Inches (mm) CH163 Series Cover 3.13 (79.5) 8 0.70 (17.8) 1.40 (35.6) 2.80 (71.2) 2.10 (53.4) 2.40 (61.0) 8 8 8 1.77 (45.0) 3.07 (78.0) 8 0.13 (3.2) 8 8 8 1.69 (43.0) Notes 1 For additional technical information, consult the Eaton web site or Customer Support Center. 2 UL recognizes both solid and stranded wire. Ferrules are not required. CSA requires ferrules on stranded wire to achieve approval. 8 V7-T8-130 Volume 7--Logic Control, Operator Interface and Connectivity Solutions CA08100008E--November 2011 www.eaton.com Terminal Blocks, Fuse Blocks and Fuse Holders Fuse Blocks and Fuse Holders C350 Series Fuse Blocks and W Series Fuse Holders 8.4 Contents Description Page C383 Series Disconnect Fuse Holders . . . . . . . . . C350 Series Fuse Blocks and W Series Fuse Holders Product Selection . . . . . . . . . . . . . . . . . . . . . . . Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . Technical Data and Specifications . . . . . . . . . . Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . V7-T8-129 8 8 8 V7-T8-132 V7-T8-133 V7-T8-133 V7-T8-133 8 8 8 8 8 8 8 8 C350 Series Fuse Blocks and W Series Fuse Holders Product Description Features Fuse Blocks These space-saving Type C350 Fuse Blocks are UL approved for motor loads and are rated 600V, 30A. Fuse Blocks Mount to 35 mm flat and 32 mm asymmetrical DIN rails 600V, 30A rated captive pressure plate terminals with copper alloy fuse clips Interlocking fuse blocks permit single, double or three-pole application-- reduce inventory Class CC fuses have an interrupting rating of 200,000A Rejection feature prevents insertion of fuses with lower interrupting or voltage ratings Fuse Holders Class H, M and R Fuse Holders Break-resistant: molded of heat-stabilized nylon Fuse clips: springreinforced for cool operation Fuse clip terminations: one-piece construction Universal mounting dimensions, for easy assembly and retrofit Breathing action collar: maintenance-free Pressure wire connectors: vibration resistant Standards and Certifications 8 Contact Eaton for the latest UL 508A short circuit ratings on terminal blocks. 8 8 Fuse Blocks UL listed CSA certified 8 8 8 Fuse Holders UL tested for OEM subfeed applications 8 8 8 8 Fuse Blocks and Adapters 8 8 Cat. No. C350KD DIN Rail Adapter 8 8 8 Cat. No. C350BD3C61 Three-Pole with Adapter (Mounted on DIN Rail) 8 8 Cat. No. C350B1C61 One-Pole Fuse Blocks 8 8 Volume 7--Logic Control, Operator Interface and Connectivity Solutions CA08100008E--November 2011 www.eaton.com V7-T8-131 8.4 8 Terminal Blocks, Fuse Blocks and Fuse Holders Fuse Blocks and Fuse Holders Product Selection Class CC Fuse Blocks 8 8 8 Type Catalog Number Three-pole 1 C350BD3C61 Single-pole C350B1C61 DIN adapter C350KD 8 8 Class R, Three-Pole Fuse Holder 8 Fuse Holders--250V 30A Wire Termination 60A Number of Poles Carton Qty. Catalog Number Carton Qty. Catalog Number 1 10 W231HA 10 W261HA 2 5 W232HA 5 W262HA 3 5 W233HA 5 W263HA 1 10 WR231HA -- -- 2 -- -- -- -- 3 5 WR233HA 1 WR263HA Number of Poles Carton Qty. Catalog Number Carton Qty. Catalog Number 1 10 W631HA 1 W661HA 2 5 W632HA 1 W662HA 3 1 W633HA 2 W663HA 1 10 WM631F -- -- 2 8 WM632F -- -- 3 6 WM633F -- -- 1 10 WM631G -- -- 2 8 WM632G -- -- 3 6 WM633G -- -- 1 10 WR631HA -- -- 2 5 WR632HA -- -- 3 5 WR633HA 5 WR663HA 1 -- -- -- -- 2 1 WMR632F -- -- 3 6 WMR633F -- -- 1 10 WMR631G -- -- 3 6 WMR633G -- -- WRR633G -- -- Class H Fuse Holders 8 Single collar (box lug)-- sized to ampere rating 8 8 Class R Fuse Holders Single collar (box lug)-- sized to ampere rating 8 8 8 Fuse Holders--600V 30A 8 Wire Termination 8 60A Class H Fuse Holders Single collar (box lug)-- sized to ampere rating 8 8 Class M Fuse Holders 8 Combination of double quick-connect, 20A max., and binding head screw, #10 max., Cu/Al 8 Combination of double quick-connect, 20A max., and pressure plate screw, #10 max., Cu only 8 8 Class R Fuse Holders 8 Single collar (box lug)-- sized to ampere rating 8 Combination of double quick-connect, 20A max., and binding head screw, #10 max., Cu/Al 8 8 Combination of double quick-connect, 20A max., and pressure plate screw, #10 max., Cu only 8 8 Class R Fuse Holder, Type WRR Control Transformer Fuse Blocks 8 Combination of double quick-connect, 20A max., and pressure plate screw, #14-#10 Cu only 8 3 6 Note 1 Three-pole device is supplied with DIN rail adapter. 8 V7-T8-132 Volume 7--Logic Control, Operator Interface and Connectivity Solutions CA08100008E--November 2011 www.eaton.com 8.4 Terminal Blocks, Fuse Blocks and Fuse Holders Fuse Blocks and Fuse Holders Accessories 8 Fuse Holder Accessories Description Catalog Number Fuse puller TBP Lighted fuse puller (120 Vac) TBLP 8 8 8 Technical Data and Specifications 8 Fuse Blocks Description Specification Voltage rating 600V Ampere rating Pressure plate terminals rated for 30A Dielectric strength 1200V maximum Ambient temperature 221F (105C) maximum Clip/terminals Tin-plated copper alloy Screw and captive pressure plate Zinc-plated steel 8 8 8 8 Base Thermoplastic UL 94VO flammability rating DIN rail adapter Thermoplastic UL 94VO flammability rating 8 8 Dimensions Approximate Dimensions in Inches (mm) 8 Fuse Blocks 8 8 8 3.00 (76.2) 0.60 (15.2) 1.25 (31.8) 8 2.24 (56.9) 0.78 (19.8) Catalog No. C350 Fuse Block 8 2.35 (59.7) Three-Pole Width Three-Pole Width Catalog No. C350 Fuse Block with DIN Rail Adapter 8 8 Fuse Holders Class H & R 250V, 30A Class M & R 600V, 30A SinglePole F Dia. A TwoPole A ThreePole A SinglePole C B D D1 D1 Width A A E ThreePole Class TwoPole ThreePole Height B Depth C H, R 250V, 30A 1.00 (25.4) 2.00 (50.8) 3.00 (76.2) 3.13 (79.5) 1.56 (39.6) 250V, 60A 1.44 (36.6) 2.88 (73.2) 4.31 (109.5) 4.75 (120.7) 600V, 30/60A 1.69 (42.9) 3.38 (85.9) 5.06 (128.5) 600V, 30A 1.63 (41.4) 2.41 (61.2) A D D1 8 C E B E 8 8 D D1 Number of Mounting Holes 8 Single- TwoPole Pole ThreePole 8 Mounting Holes SinglePole 0.84 (21.3) F Dia. TwoPole A D Volts/ Amperes M, R Class H & R 250V, 60A 600V, 30/60A D Two-Pole D1 Three-Pole D1 E Diameter F 0.38 (9.7) 1.25 (31.8) 2.50 (63.5) -- 0.22 (5.6) 2 2 2 2.06 (52.3) 0.50 (12.7) 1.81 (46.0) 3.13 (79.5) 1.25 (31.8) 0.22 (5.6) 2 4 4 6.94 (176.3) 2.63 (66.8) 0.63 (16.0) 2.19 (55.6) 3.75 (95.3) 3.13 (79.5) 0.28 (7.1) 2 4 4 3.00 (76.2) 1.28 (32.5) 0.38 (9.7) 0.75 (19.1) 1.50 (38.1) -- 0.17 (4.3) 2 2 2 8 8 8 8 8 8 Volume 7--Logic Control, Operator Interface and Connectivity Solutions CA08100008E--November 2011 www.eaton.com V7-T8-133 8.4 Terminal Blocks, Fuse Blocks and Fuse Holders Fuse Blocks and Fuse Holders 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 V7-T8-134 Volume 7--Logic Control, Operator Interface and Connectivity Solutions CA08100008E--November 2011 www.eaton.com