Inclination sensor INX360D-F99-I2E2-V15 Technical Data General specifications Type Measurement range Absolute accuracy Response delay Resolution Repeat accuracy Temperature influence Functional safety related parameters MTTFd Mission Time (TM) Diagnostic Coverage (DC) Indicators/operating means Operating display TEACH-IN indication Button Model number INX360D-F99-I2E2-V15 Features * Measuring range 0 ... 360 * Analog output 4 mA ... 20 mA * Evaluation limits can be taught-in * 2 programmable switch outputs * High shock resistance * e1-Type approval * Increased noise immunity 100 V/m Electrical connection Standard symbol/Connection: 1 2 I 4 5 3 +UB Out 2 Inclination sensor, 1-axis 0 ... 360 0.5 20 ms 0.1 0.1 0.027 /K 300 a 20 a 0% LED, green 2 LEDs yellow (switching status), flashing 2 push-buttons ( Switch points programming , Evaluation range programming ) 2 yellow LEDs: Switching status (each output) Switching state Electrical specifications Operating voltage UB No-load supply current I0 Time delay before availability tv Switching output Output type 10 ... 30 V DC 25 mA 200 ms 2 switch outputs PNP, NO , reverse polarity protected , short-circuit protected 100 mA 3V Operating current IL Voltage drop Analog output Output type Load resistor 1 current output 4 ... 20 mA 0 ... 200 at UB = 10 ... 18 V 0 ... 500 at UB = 18 ... 30 V Ambient conditions Ambient temperature Storage temperature Mechanical specifications Connection type Housing material Protection degree Mass Compliance with standards and directives Standard conformity Shock and impact resistance Standards -40 ... 85 C (-40 ... 185 F) -40 ... 85 C (-40 ... 185 F) M12 x 1 connector, 5-pin PA IP68 / IP69K 240 g 100 g according to DIN EN 60068-2-27 EN 60947-5-2:2007 IEC 60947-5-2:2007 Out 1 Analogue output -UB Approvals and certificates CSA approval cCSAus Listed, General Purpose, Class 2 Power Source CCC approval CCC approval / marking not required for products rated 36 V e1 Type approval 2006/28/EG Release date: 2013-04-22 13:56 Date of edition: 2013-04-22 201503_eng.xml EMC Properties Emitted interference and interference immunity in accordance with motor vehicle directive 2006/28/EG (e1 Type approval) Interference immunity in accordance with DIN ISO 11452-2: 100 V/m Frequency band 20 MHz up to 2 GHz Mains-borne interference in accordance with ISO 7637-2: Pulse Severity level Failure criterion 1 III C EN 61000-4-2: Severity level EN 61000-4-3: Severity level EN 61000-4-4: Severity level EN 61000-4-6: Severity level EN 55011: CD: 8 kV / AD: 15 kV IV IV 30 V/m (80...2500 MHz) IV 2 kV III 10 V (0.01...80 MHz) III Klasse A Refer to "General Notes Relating to Pepperl+Fuchs Product Information". Pepperl+Fuchs Group USA: +1 330 486 0001 Germany: +49 621 776 4411 fa-info@de.pepperl-fuchs.com www.pepperl-fuchs.com fa-info@us.pepperl-fuchs.com 2a III A 2b III C 3a III A 3b III A 4 III C Singapore: +65 6779 9091 fa-info@sg.pepperl-fuchs.com 1 Inclination sensor INX360D-F99-I2E2-V15 Pinout Dimensions 1 5 18.5 4 2 M12 7 3 30 LEDs Button 7 Wire colors in accordance with EN 60947-5-2 1 2 3 4 5 37 64 10 45 10 BN WH BU BK GY (brown) (white) (blue) (black) (gray) 4 x o 5.5 Accessories 65 V15-G-2M-PUR Female cordset, M12, 5-pin, PUR cable V15-W-2M-PUR Female cordset, M12, 5-pin, PUR cable Sensor Orientation In the default setting the zero position of the sensor is reached, when the electrical connection faces straight upwards. - On request, all required mounting positions can be preset at the factory. For example: X = 0 if the electrical connection points straight downwards. X Orientation - + X = 0 X = 90 X = 180 X = 270 (-90) Mounting of the sensor 6. 3 Nm 7. 4. 2. 1. 5. 1. 2. 3. 4. Loosen the central screw under the sensor connection. Slide back the clamping element until you are able to remove the sensor module from the housing. Remove the sensor module from the housing Position the housing at the required mounting location and secure using four countersunk screws. Make sure that the heads of the screws do not protrude. 5. Place the sensor module in the housing. 6. Slide the clamping element flush into the housing. Check that the sensor element is seated correctly. 7. Finally tighten the central screw. The sensor is now mounted correctly. LED display 2 Refer to "General Notes Relating to Pepperl+Fuchs Product Information". Pepperl+Fuchs Group USA: +1 330 486 0001 Germany: +49 621 776 4411 fa-info@de.pepperl-fuchs.com www.pepperl-fuchs.com fa-info@us.pepperl-fuchs.com Singapore: +65 6779 9091 fa-info@sg.pepperl-fuchs.com Release date: 2013-04-22 13:56 3. Date of edition: 2013-04-22 201503_eng.xml Sensors from the -F99 series consist of a sensor module and accompanying cast aluminum housing. Select a vertical surface with minimum dimensions of 70 mm x 50 mm to mount the sensor. Mount the sensor as follows: Inclination sensor Displays dependent on the operating state Teach-in of switching points (output S1): Teach-in of switching points (output S2): Activate teach-in mode for analog limits: Teach-in of analog limits Normal operation Reset to factory settings: 2 s ... 10 s > 10 s ... end of reset process Followed by normal operation Undervoltage INX360D-F99-I2E2-V15 LED green: Power off off off off on LED yellow out 1 flashes off flashes flashes switchingstate LED yellow out 2 off flashes flashes off switchingstate off flashes flashes off flashes off flashes off off Axis definition The definition of the X-axis is shown on the sensor housing by means of an imprinted and labeled double arrow. The figure shows the clockwise direction of rotation. Teach-in of switching points (output S1) 1. 2. 3. 4. 5. 6. Press key T1 > 2 s (see LED display) Move sensor to switching position 1 Press key T1 briefly. LED "out 1" lights for 1.5 s as confirmation. Switching point 1 has been taught Move sensor to switching position 2 Press key T1 briefly. LED "out 1" lights for 1.5 s as confirmation. Switching point 2 has been taught Sensor returns to normal operation (see LED display) If the switching points are taught in clockwise direction, the switching output between these switching points works as a NO contact. If the switching points are taught in anticlockwise direction, the switching output between these switching points works as a NC contact. X Teach-in of switching points (output S2) Similar to the process for "Teach-in of switching points (output S1)", but with key T2 instead of key T1. Teach-in of analog limits 1. 2. 3. 4. 5. 6. 7. Activate the teach-in mode for the analog limits by simultaneously pressing keys T1 and T2 until the green LED is extinguished and the two yellow LEDs flash. Then release the keys. Press key T1 > for 2 s (see LED display) Move the sensor into the position of minimum evaluation limit Press key T1 briefly. LED "out 1" lights for 1.5 s as confirmation. The minimum evaluation limit has been taught. In this position the analog output will provide its minimum output value. Move the sensor into the position of maximum evaluation limit Press key T1 briefly. LED "out 1" lights for 1.5 s as confirmation. The maximum evaluation limit has been taught. In this position the analog output will provide its maximum output value. Sensor returns to normal operation (see LED display) If the sensor inclination exceeds one of the analog limits, the last value of the analog output is retained. Resetting the sensor to factory settings 1. Press keys T1 and T2 > 10 s (see LED display) 2. The sensor has been reset when the green LED "Power" lights again after approx. 10 s. Undervoltage detection Release date: 2013-04-22 13:56 Date of edition: 2013-04-22 201503_eng.xml If the supply voltage falls below a value of approx. 7 V, all outputs and yellow LEDs are deactivated. The green "power" LED flashes rapidly. If the supply voltage falls below a value of approx. 8 V, the sensor continues with normal operation. Refer to "General Notes Relating to Pepperl+Fuchs Product Information". Pepperl+Fuchs Group USA: +1 330 486 0001 Germany: +49 621 776 4411 fa-info@de.pepperl-fuchs.com www.pepperl-fuchs.com fa-info@us.pepperl-fuchs.com Singapore: +65 6779 9091 fa-info@sg.pepperl-fuchs.com 3