EcoFlexTM Cable Smaller. Lighter. Tougher. 100% Recyclable. Total Performance, Completely Recyclable EcoFlex cable is Alpha Wire's newest innovation in control cabling. A true engineering breakthrough, EcoFlex cable combines better performance with a minimum environmental impact. It derives its advantages from modified polyphenylene ether (mPPE) jacketing and insulation. EcoFlex is: * 100% Recyclable * Up to 32% smaller * Up to 55% lighter * C apable of handling temperatures extremes to -40C * Up to 91% lower outgassing * R ated for over 1 million flex cycles mPPE Insulation: All the Advantages in Smaller, Lighter Control Cable Environmentally Friendly Better Dielectric Strength Superior Availability EcoFlex cable contains no halogens, phthalates, or heavy metals. The mPPE thermoplastic insulation and jacketing can be easily recycled. They meet RoHS and WEEE requirements for the elimination of hazardous substances and recyclability. The superior dielectric properties of mPPE make a reduced wall thickness possible, while maintaining the same electrical properties as a thicker PVC control cable. EcoFlex cables are available from stock in most sizes and constructions, with put-ups as small as 100 feet. Alpha Wire provides same-day shipment and next-day delivery to practically anywhere in the world. Low Specific Gravity Alpha Wire offers EcoFlex cable in three shielding options to handle any electrical environment. The 1.03 specific gravity of mPPE is 25% to 40% lower than other insulation materials, such as PVC, polyethylene, and cross-linked polyethylene. Along with the reduced wall thickness, the low specific gravity yields significant weight savings of up to 55% with EcoFlex cable. More Choice in EMI Protection Visit www.alphawire.com/ EcoGen to request free samples * Unshielded * Braid Shielded * S upraShield(R) Foil + Braid Shield Alpha Wire's next generation of eco-friendly, high-performance wire and cable, designed to provide better performance in a smaller package. * EcoCableTM * EcoFlexTM Cable Properties Diameter Weight Temperature Range Outgassing Recyclability Availability EcoFlex Cable Up to 32% smaller 55% lighter -40C to 105C static, -5C to 105C Flexing 91% lower 100% 100', 1000' * EcoWireTM * EcoWireTM Plus Learn more about the new EcoGen family of products at www.alphawire.com/EcoGen EcoFlex Cable Specifications Request free samples at www.alphawire.com/ EcoFlex Materials Key Features Conductor No Conductors: Stranded tin-plated copper Insulation: mPPE Jacket: mPPE, slate * C ompact cable for moderate flex applications No. Base Color * R ated for more than 1 million flex cycles 1 Black 2 Red 3 White Approvals 4 Green * U L AWM 21819 (600 V, 105C) 5 Orange * UL AWM 21492 (300 V, 80C) 6 Blue * CE 7 Brown 8 Yellow 9 Violet * REACH Compliant 10 Slate * WEEE * Suitable for use in NFPA79 Applications 11 Pink 12 Tan 13 Red Green 14 Red Yellow 15 Red Black 16 White Black 17 White Red 18 White Green 19 White Yellow 20 White Blue 21 White Brown 22 White Orange 23 White Slate 24 White Violet 25 White Black Electrical Voltage: 600 V Bend Radius Unshielded: 5x Static, 5x Flexing Shielded: 6x Static, 8x Flexing Physical and Mechanical Temperature Range: -40C to 105C Availability 100 ft (30.5 m) and 1000 ft (305 m) lengths * Easier routing and handling * UL VW-1 * RoHS Compliant * CSA AWM I/II A/B FT1 * IEC 60332-2 Flame Behavior 20 AWG (0.51 mm2) Cable 1st Stripe 2nd Stripe Red EcoFlex Cable Unshielded 28 AWG (0.09 mm2) 24 AWG (0.24 mm2) Stranding: 7/36 (7 x 0.13 mm) Insulation thickness: 0.010 (0.25 mm) Jacket thickness: 0.035 (0.89 mm) Stranding: 19/36 (19 x 0.13 mm) Insulation thickness: 0.010 (0.25 mm) Jacket thickness: 0.035 (0.89 mm) Nominal Diameter Part Number Conductors Inch mm 79061 2 0.142 3.61 79062 3 0.147 3.73 Part Number Nominal Diameter Part Number Conductors Inch mm 79050 2 0.162 4.11 79051 3 0.169 4.29 79052 4 0.181 4.60 79053 6 0.207 5.26 79054 8 0.238 6.05 79055 10 0.257 6.53 26 AWG (0.14 mm2) 22 AWG (0.38 mm2) Stranding: 7/34 (7 x 0.16 mm) Insulation thickness: 0.010 (0.25 mm) Jacket thickness: 0.035 (0.89 mm) Stranding: 19/34 (19 x 0.16 mm) Insulation thickness: 0.010 (0.25 mm) Jacket thickness: 0.035 (0.89 mm) Conductors Nominal Diameter Inch mm 79056 2 0.150 3.81 79057 3 0.156 3.96 79058 4 0.166 4.22 79059 6 0.189 4.80 79060 8 0.216 5.49 Nominal Diameter Part Number Conductors Inch mm 79044 2 0.176 4.47 79045 3 0.184 4.67 79046 4 0.198 5.03 79047 6 0.228 5.79 79048 8 0.264 6.71 79049 10 0.286 7.26 20 AWG (0.51 mm2) Stranding: 10/30 (10 x 0.25 mm) Insulation thickness: 0.010 (0.25 mm) Jacket thickness: 0.035 (0.89 mm) Part Number Conductors Nominal Diameter Inch mm 79001 2 0.184 4.67 79002 3 0.193 4.90 79003 4 0.207 5.26 79004 5 0.224 5.69 79005 7 0.240 6.10 79006 9 0.296 7.52 79007 12 0.303 7.70 79008 18 0.349 8.86 EcoFlex Cable Unshielded 18 AWG (0.81 mm2) 12 AWG (3.29 mm2) Stranding: 16/30 (16 x 0.25 mm) Insulation thickness: 0.010 (0.25 mm) Jacket thickness: 0.035 (0.89 mm) Stranding: 65/30 (65 x 0.25 mm) Insulation thickness: 0.012 (0.30 mm) Jacket thickness: 0.035 (0.81 mm) Part Number Conductors 79010 2 Nominal Diameter Inch mm 0.208 5.28 Part Number Conductors 79037 Nominal Diameter Inch mm 3 0.326 8.28 79011 3 0.219 5.56 79038 4 0.358 9.09 79012 4 0.236 5.99 79039 5 0.392 9.96 79040 7 0.428 10.87 79013 5 0.256 6.50 79014 7 0.277 7.04 79015 9 0.344 8.74 79016 12 0.353 8.97 79017 18 0.411 10.44 16 AWG (1.32 mm2) 10 AWG (5.32 mm2) Stranding: 26/30 (26 x 0.25 mm) Insulation thickness: 0.011 (0.28 mm) Jacket thickness: 0.035 (0.89 mm) Stranding: 105/30 (105 x 0.25 mm) Insulation thickness: 0.012 (0.30 mm) Jacket thickness: 0.035 (0.81 mm) Nominal Diameter Part Number Conductors Part Number Conductors Inch mm 79019 2 0.236 5.99 79041 3 79020 3 79021 4 0.249 6.32 79042 0.270 6.86 79043 79022 5 0.294 7.47 79023 7 0.319 8.10 79024 9 0.400 10.16 79025 12 0.411 10.44 79026 18 0.481 12.22 14 AWG (2.08 mm2) Stranding: 41/30 (41 x 0.25 mm) Insulation thickness: 0.011 (0.28 mm) Jacket thickness: 0.035 (0.81 mm) Part Number Conductors Nominal Diameter Inch mm 79028 2 0.266 6.76 79029 3 0.281 7.14 79030 4 0.307 7.80 79031 5 0.335 8.51 79032 7 0.364 9.25 79033 9 0.459 11.66 79034 12 0.473 12.01 79035 18 0.556 14.12 Nominal Diameter Inch mm 0.38 9.65 4 0.423 10.74 5 0.465 11.81 EcoFlex Cable Braid Shield 20 AWG (0.51 mm2) 16 AWG (1.32 mm2) Stranding: 10/30 (10 x 0.25 mm) Insulation thickness: 0.010 (0.25 mm) Jacket thickness: 0.035 (0.89 mm) Stranding: 26/30 (26 x 0.25 mm) Insulation thickness: 0.011 (0.28 mm) Jacket thickness: 0.035 (0.89 mm) Part Number Conductors 79101 2 Nominal Diameter Inch mm 0.210 5.33 Part Number Conductors 79116 2 Nominal Diameter Inch mm 0.262 6.65 79102 3 0.219 5.56 79117 3 0.275 6.98 79103 4 0.233 5.92 79118 4 0.396 10.06 79104 5 0.250 6.35 79119 5 0.320 8.13 79105 7 0.266 6.76 79120 7 0.345 8.76 79106 9 0.321 8.15 79107 12 0.329 8.36 79108 18 0.376 9.55 18 AWG (0.81 mm2) 14 AWG (2.08 mm2) Stranding: 16/30 (16 x 0.25 mm) Insulation thickness: 0.010 (0.25 mm) Jacket thickness: 0.035 (0.89 mm) Stranding: 41/30 (41 x 0.25 mm) Insulation thickness: 0.011 (0.28 mm) Jacket thickness: 0.035 (0.81 mm) Part Number Conductors 79109 2 Nominal Diameter Nominal Diameter Part Number Conductors Inch mm 2 0.294 7.47 Inch mm 0.236 5.99 79121 79110 3 0.247 6.27 79122 3 0.309 7.85 79111 4 0.264 6.71 79123 4 0.335 8.51 79112 5 0.284 7.21 79124 5 0.363 9.22 79125 7 0.392 9.96 79113 7 0.305 7.75 79114 9 0.372 9.45 79115 12 0.381 9.68 12 AWG (3.29 mm2) Stranding: 65/30 (65 x 0.25 mm) Insulation thickness: 0.012 (0.30 mm) Jacket thickness: 0.035 (0.81 mm) Part Number Conductors Nominal Diameter Inch mm 79126 3 0.354 8.99 79127 4 0.386 9.80 EcoFlex Cable Supra-Shield(R) Foil + Braid 28 AWG (0.09 mm2) 22 AWG (0.38 mm2) Stranding: 7/36 (7 x 0.13 mm) Insulation thickness: 0.010 (0.25 mm) Jacket thickness: 0.035 (0.89 mm) Stranding: 19/34 (19 x 0.16 mm) Insulation thickness: 0.010 (0.25 mm) Jacket thickness: 0.035 (0.89 mm) Part Number Conductors 79261 79262 Nominal Diameter Inch mm 2 0.174 4.42 3 0.179 4.55 Part Number Conductors 79244 Nominal Diameter Inch mm 2 0.208 5.28 79245 3 0.216 5.49 79246 4 0.23 5.84 79247 6 0.26 6.60 79248 8 0.296 7.52 79249 10 0.318 8.08 26 AWG (0.14 mm2) 20 AWG (0.51 mm2) Stranding: 7/34 (7 x 0.16 mm) Insulation thickness: 0.010 (0.25 mm) Jacket thickness: 0.035 (0.89 mm) Stranding: 10/30 (10 x 0.25 mm) Insulation thickness: 0.010 (0.25 mm) Jacket thickness: 0.035 (0.89 mm) Part Number Conductors 79256 2 Nominal Diameter Part Number Conductors 2 Inch mm 0.182 4.62 79201 Nominal Diameter Inch mm 0.216 5.49 79257 3 0.188 4.78 79202 3 0.225 5.72 79258 4 0.198 5.03 79203 4 0.239 6.07 79259 6 0.221 5.61 79204 5 0.256 6.50 79260 8 0.248 6.30 24 AWG (0.24 mm2) Stranding: 19/36 (19 x 0.13 mm) Insulation thickness: 0.011 (0.25 mm) Jacket thickness: 0.035 (0.89 mm) Part Number Conductors Nominal Diameter Inch mm 79250 2 0.194 4.93 79251 3 0.201 5.11 79252 4 0.213 5.41 79253 6 0.239 6.07 79254 8 0.27 6.86 79255 10 0.289 7.34 79205 7 0.272 6.91 79206 9 0.328 8.33 79207 12 0.335 8.51 79208 18 0.382 9.70 EcoFlex Cable Supra-Shield(R) Foil + Braid 18 AWG (0.81 mm2) 12 AWG (3.29 mm2) Stranding: 16/30 (16 x 0.25 mm) Insulation thickness: 0.010 (0.25 mm) Jacket thickness: 0.035 (0.89 mm) Stranding: 65/30 (65 x 0.25 mm) Insulation thickness: 0.012 (0.30 mm) Jacket thickness: 0.035 (0.81 mm) Part Number Conductors 79210 2 Nominal Diameter Inch mm 0.242 6.15 Part Number Conductors 79232 3 Nominal Diameter Inch mm 0.360 9.14 79211 3 0.253 6.43 79233 4 0.391 9.93 79212 4 0.270 6.86 79234 5 0.426 10.82 79235 7 0.462 11.73 79213 5 0.290 7.37 79214 7 0.311 7.90 79215 9 0.378 9.60 79216 12 0.387 9.83 79217 18 0.445 11.30 16 AWG (1.32 mm2) 10 AWG (5.32 mm2) Stranding: 26/30 (26 x 0.25 mm) Insulation thickness: 0.011 (0.28 mm) Jacket thickness: 0.035 (0.89 mm) Stranding: 105/30 (105 x 0.25 mm) Insulation thickness: 0.012 (0.30 mm) Jacket thickness: 0.035 (0.81 mm) Part Number Conductors 79218 2 Nominal Diameter Nominal Diameter Inch mm Inch mm 6.81 79236 3 0.419 10.64 79237 4 0.457 11.61 79219 3 0.281 7.14 4 0.302 7.67 79221 5 0.326 8.28 79222 7 0.351 8.92 79223 9 0.432 10.97 79224 12 0.443 11.25 14 AWG (2.08 mm2) Stranding: 41/30 (41 x 0.25 mm) Insulation thickness: 0.011 (0.28 mm) Jacket thickness: 0.035 (0.81 mm) Conductors Conductors 0.268 79220 Part Number Part Number Nominal Diameter Inch mm 79225 2 0.300 7.62 79226 3 0.315 8.00 79227 4 0.341 8.66 79228 5 0.369 9.37 79229 7 0.398 10.11 79230 9 0.493 12.52 79231 12 0.507 12.88 Cables you trust. Service you deserve. Superior availability Every application is critical and cable failure is not an option when the safety of your equipment and personnel is paramount. Specify Alpha products since the integrity of your system is only as robust as the products you use. Alpha offers wire and cable from stock in most sizes and constructions, in both small and large put-ups, so you can order it when you need it. Our products are available for same-day shipment, eliminating long lead times. GLOBAL HEADQUARTERS 711 Lidgerwood Avenue Elizabeth, NJ 07207-0711 USA Toll Free: 1-800-52 ALPHA Tel: 1-908-925-8000 Fax: 1-908-925-5411 E-mail: info@alphawire.com EUROPE Alpha Wire International Saxon House 1 Downside | Sunbury-on-Thames Middlesex | United Kingdom TW16 6RT Tel: +44-(0)-800-288-8809 Fax: +44-(0)-800-288-8810 E-mail: europe@alphawire.com Service and support, second-to-none Selecting the correct cable for your critical application is essential to overall system reliability, performance, and safety. So we make it easy for you select the right Alpha product for your specific application. Our online resources include a wire and cable selection guide, technical information, full product catalog, and a distributor locator to make it easy to select and get the wire or cable you need. Can't find what you're looking for? Design the cable to your specification. It's easy, just visit www.alphawire.com! ASIA PACIFIC Alpha Wire Silver Center | Room 1708 North Shanxi Road 1388 Shanghai | China | 200060 Tel: +86-21-61498201/61498205 Fax: +86-21-61498001 E-mail: apac@alphawire.com Alpha Wire's next generation of eco-friendly, high-performance wire and cable, designed to provide better performance in a smaller package. (c)2012 Alpha Wire. All rights reserved. Specifications subject to change. Consult Alpha Wire for latest specifications. EcoCable, EcoFlex, EcoGen, EcoWire, and EcoWire Plus are trademarks of Alpha Wire. Lit. No. EcoF-Bro-1212 Supersedes: New