MPLAB(R) ICD 3 In-Circuit Debugger User's Guide (c) 2008 Microchip Technology Inc. DS51766A Note the following details of the code protection feature on Microchip devices: * Microchip products meet the specification contained in their particular Microchip Data Sheet. * Microchip believes that its family of products is one of the most secure families of its kind on the market today, when used in the intended manner and under normal conditions. * There are dishonest and possibly illegal methods used to breach the code protection feature. All of these methods, to our knowledge, require using the Microchip products in a manner outside the operating specifications contained in Microchip's Data Sheets. Most likely, the person doing so is engaged in theft of intellectual property. * Microchip is willing to work with the customer who is concerned about the integrity of their code. * Neither Microchip nor any other semiconductor manufacturer can guarantee the security of their code. Code protection does not mean that we are guaranteeing the product as "unbreakable." Code protection is constantly evolving. We at Microchip are committed to continuously improving the code protection features of our products. Attempts to break Microchip's code protection feature may be a violation of the Digital Millennium Copyright Act. If such acts allow unauthorized access to your software or other copyrighted work, you may have a right to sue for relief under that Act. Information contained in this publication regarding device applications and the like is provided only for your convenience and may be superseded by updates. It is your responsibility to ensure that your application meets with your specifications. MICROCHIP MAKES NO REPRESENTATIONS OR WARRANTIES OF ANY KIND WHETHER EXPRESS OR IMPLIED, WRITTEN OR ORAL, STATUTORY OR OTHERWISE, RELATED TO THE INFORMATION, INCLUDING BUT NOT LIMITED TO ITS CONDITION, QUALITY, PERFORMANCE, MERCHANTABILITY OR FITNESS FOR PURPOSE. Microchip disclaims all liability arising from this information and its use. Use of Microchip devices in life support and/or safety applications is entirely at the buyer's risk, and the buyer agrees to defend, indemnify and hold harmless Microchip from any and all damages, claims, suits, or expenses resulting from such use. No licenses are conveyed, implicitly or otherwise, under any Microchip intellectual property rights. Trademarks The Microchip name and logo, the Microchip logo, Accuron, dsPIC, KEELOQ, KEELOQ logo, MPLAB, PIC, PICmicro, PICSTART, rfPIC, SmartShunt and UNI/O are registered trademarks of Microchip Technology Incorporated in the U.S.A. and other countries. FilterLab, Linear Active Thermistor, MXDEV, MXLAB, SEEVAL, SmartSensor and The Embedded Control Solutions Company are registered trademarks of Microchip Technology Incorporated in the U.S.A. Analog-for-the-Digital Age, Application Maestro, CodeGuard, dsPICDEM, dsPICDEM.net, dsPICworks, dsSPEAK, ECAN, ECONOMONITOR, FanSense, In-Circuit Serial Programming, ICSP, ICEPIC, Mindi, MiWi, MPASM, MPLAB Certified logo, MPLIB, MPLINK, mTouch, PICkit, PICDEM, PICDEM.net, PICtail, PIC32 logo, PowerCal, PowerInfo, PowerMate, PowerTool, REAL ICE, rfLAB, Select Mode, Total Endurance, WiperLock and ZENA are trademarks of Microchip Technology Incorporated in the U.S.A. and other countries. SQTP is a service mark of Microchip Technology Incorporated in the U.S.A. All other trademarks mentioned herein are property of their respective companies. (c) 2008, Microchip Technology Incorporated, Printed in the U.S.A., All Rights Reserved. Printed on recycled paper. Microchip received ISO/TS-16949:2002 certification for its worldwide headquarters, design and wafer fabrication facilities in Chandler and Tempe, Arizona; Gresham, Oregon and design centers in California and India. The Company's quality system processes and procedures are for its PIC(R) MCUs and dsPIC(R) DSCs, KEELOQ(R) code hopping devices, Serial EEPROMs, microperipherals, nonvolatile memory and analog products. In addition, Microchip's quality system for the design and manufacture of development systems is ISO 9001:2000 certified. DS51766A-page ii (c) 2008 Microchip Technology Inc. MPLAB(R) ICD 3 IN-CIRCUIT DEBUGGER USER'S GUIDE Table of Contents Preface ........................................................................................................................... 1 Part 1 -Getting Started Chapter 1. Overview 1.1 Introduction ..................................................................................................... 9 1.2 MPLAB ICD 3 In-Circuit Debugger Defined ................................................... 9 1.3 How the MPLAB ICD 3 In-Circuit Debugger Helps You ............................... 10 1.4 MPLAB ICD 3 In-Circuit Debugger Kit Components .................................... 10 1.5 Device and Feature Support ........................................................................ 11 Chapter 2. Theory of Operation 2.1 Introduction ................................................................................................... 13 2.2 MPLAB ICD 3 In-Circuit Debugger vs. MPLAB ICE 2000/4000 In-Circuit Emulators ................................................................................ 13 2.3 MPLAB ICD 3 In-Circuit Debugger vs. MPLAB ICD 2 Debugger ................. 13 2.4 Debugger To Target Communication ........................................................... 14 2.5 Communication Connections ....................................................................... 15 2.6 Debugging with the Debugger ...................................................................... 17 2.7 Requirements For Debugging ...................................................................... 18 2.8 Programming with the Debugger .................................................................. 20 2.9 Resources Used by the Debugger ............................................................... 20 Chapter 3. Installation 3.1 Introduction ................................................................................................... 21 3.2 Installing the Software .................................................................................. 21 3.3 Installing the USB Device Drivers ................................................................ 21 3.4 Connecting the Target .................................................................................. 22 3.5 Setting Up the Target Board ......................................................................... 22 3.6 Setting Up MPLAB IDE ................................................................................ 23 Chapter 4. General Setup 4.1 Introduction ................................................................................................... 25 4.2 Starting the MPLAB IDE Software ................................................................ 25 4.3 Creating a Project ......................................................................................... 26 4.4 Viewing the Project ....................................................................................... 26 4.5 Building the Project ...................................................................................... 26 4.6 Setting Configuration Bits ............................................................................. 27 4.7 Setting the Debugger as the Debugger or Programmer ............................... 27 4.8 Debugger/Programmer Limitations .............................................................. 27 (c) 2008 Microchip Technology Inc. DS51766A-page iii MPLAB(R) ICD 3 In-Circuit Debugger User's Guide Chapter 5. Tutorial 5.1 Introduction ................................................................................................... 29 5.2 Setting Up the Environment and Selecting the Device ................................. 30 5.3 Creating the Application Code ...................................................................... 30 5.4 Running the Project Wizard .......................................................................... 33 5.5 Viewing the Project ....................................................................................... 35 5.6 Viewing Debug Options ................................................................................ 36 5.7 Creating a Hex File ....................................................................................... 37 5.8 Setting Up the Demo Board ......................................................................... 39 5.9 Loading Program Code For Debugging ....................................................... 39 5.10 Running Debug Code ................................................................................. 40 5.11 Debugging Code Using Breakpoints .......................................................... 40 5.12 Programming the Application ..................................................................... 45 Part 2 -Troubleshooting Chapter 6. Frequently Asked Questions (FAQs) 6.1 Introduction ................................................................................................... 49 6.2 How Does It Work ........................................................................................ 49 6.3 What's Wrong ............................................................................................... 50 Chapter 7. Error Messages 7.1 Introduction ................................................................................................... 53 7.2 Specific Error Messages .............................................................................. 53 7.3 General Corrective Actions .......................................................................... 57 Part 3 -Reference Chapter 8. Basic Debug Functions 8.1 Introduction ................................................................................................... 63 8.2 Breakpoints .................................................................................................. 63 8.3 Stopwatch ..................................................................................................... 63 Chapter 9. Debugger Function Summary 9.1 Introduction ................................................................................................... 65 9.2 Debugging Functions ................................................................................... 65 9.3 Debugging Dialogs/Windows ....................................................................... 68 9.4 Programming Functions ............................................................................... 73 9.5 Settings Dialog ............................................................................................. 74 DS51766A-page iv (c) 2008 Microchip Technology Inc. Table of Contents Chapter 10. Hardware Specification 10.1 Introduction ................................................................................................. 79 10.2 Highlights .................................................................................................... 79 10.3 Declaration of Conformity ........................................................................... 79 10.4 USB Port/Power ......................................................................................... 80 10.5 MPLAB ICD 3 Debugger ............................................................................ 80 10.6 Standard Communication Hardware .......................................................... 81 10.7 ICD 3 Test Interface Board ......................................................................... 82 10.8 Target Board Considerations ..................................................................... 83 Glossary ....................................................................................................................... 85 Index ............................................................................................................................. 99 Worldwide Sales and Service .................................................................................. 102 (c) 2008 Microchip Technology Inc. DS51766A-page v MPLAB(R) ICD 3 In-Circuit Debugger User's Guide NOTES: DS51766A-page vi (c) 2008 Microchip Technology Inc. MPLAB(R) ICD 3 IN-CIRCUIT DEBUGGER USER'S GUIDE Preface NOTICE TO CUSTOMERS All documentation becomes dated, and this manual is no exception. Microchip tools and documentation are constantly evolving to meet customer needs, so some actual dialogs and/or tool descriptions may differ from those in this document. Please refer to our web site (www.microchip.com) to obtain the latest documentation available. Documents are identified with a "DS" number. This number is located on the bottom of each page, in front of the page number. The numbering convention for the DS number is "DSXXXXXA", where "XXXXX" is the document number and "A" is the revision level of the document. For the most up-to-date information on development tools, see the MPLAB(R) IDE on-line help. Select the Help menu, and then Topics to open a list of available on-line help files. INTRODUCTION This chapter contains general information that will be useful to know before using the MPLAB ICD 3 in-circuit debugger. Items discussed in this chapter include: * * * * * * * * Document Layout Conventions Used in this Guide Warranty Registration Recommended Reading The Microchip Web Site Development Systems Customer Change Notification Service Customer Support Revision History DOCUMENT LAYOUT This document describes how to use the MPLAB ICD 3 in-circuit debugger as a development tool to emulate and debug firmware on a target board, as well as how to program devices. The document is organized as follows: Part 1 - Getting Started * Chapter 1. Overview - What the MPLAB ICD 3 in-circuit debugger is, and how it can help you develop your application. * Chapter 2. Theory of Operation - The theory of MPLAB ICD 3 in-circuit debugger operation. Explains configuration options. * Chapter 3. Installation - How to install the debugger software and hardware. * Chapter 4. General Setup - How to set up MPLAB IDE to use the debugger. * Chapter 5. Tutorial - A brief tutorial on using the debugger. (c) 2008 Microchip Technology Inc. DS51766A-page 1 MPLAB(R) ICD 3 In-Circuit Debugger User's Guide Part 2 - Troubleshooting * Chapter 6. Frequently Asked Questions (FAQs) - A list of frequently asked questions, useful for troubleshooting. * Chapter 7. Error Messages - A list of error messages and suggested resolutions. Part 3 - Reference * Chapter 8. Basic Debug Functions - A description of basic debugger features available in MPLAB IDE when the MPLAB ICD 3 in-circuit debugger is chosen as either the debug or programming tool. This includes the debug features breakpoints, stopwatch, triggering and real-time watches. * Chapter 9. Debugger Function Summary - A summary of debugger functions available in MPLAB IDE when the MPLAB ICD 3 debugger is chosen as the debug or program tool. * Chapter 10. Hardware Specification - The hardware and electrical specifications of the debugger system. DS51766A-page 2 (c) 2008 Microchip Technology Inc. Preface CONVENTIONS USED IN THIS GUIDE This manual uses the following documentation conventions: DOCUMENTATION CONVENTIONS Description Arial font: Italic characters Initial caps Quotes Underlined, italic text with right angle bracket Bold characters N`Rnnnn Text in angle brackets < > Courier New font: Plain Courier New Represents Referenced books Emphasized text A window A dialog A menu selection A field name in a window or dialog A menu path MPLAB(R) IDE User's Guide ...is the only compiler... the Output window the Settings dialog select Enable Programmer "Save project before build" A dialog button A tab A number in verilog format, where N is the total number of digits, R is the radix and n is a digit. A key on the keyboard Click OK Click the Power tab 4`b0010, 2`hF1 Italic Courier New Sample source code Filenames File paths Keywords Command-line options Bit values Constants A variable argument Square brackets [ ] Optional arguments Curly brackets and pipe character: { | } Ellipses... Choice of mutually exclusive arguments; an OR selection Replaces repeated text Represents code supplied by user (c) 2008 Microchip Technology Inc. Examples File>Save Press , #define START autoexec.bat c:\mcc18\h _asm, _endasm, static -Opa+, -Opa0, 1 0xFF, `A' file.o, where file can be any valid filename mcc18 [options] file [options] errorlevel {0|1} var_name [, var_name...] void main (void) { ... } DS51766A-page 3 MPLAB(R) ICD 3 In-Circuit Debugger User's Guide WARRANTY REGISTRATION Please complete the enclosed Warranty Registration Card and mail it promptly. Sending in the Warranty Registration Card entitles users to receive new product updates. Interim software releases are available at the Microchip web site. RECOMMENDED READING This user's guide describes how to use MPLAB ICD 3 in-circuit debugger. Other useful documents are listed below. The following Microchip documents are available and recommended as supplemental reference resources. Please read this first! This document contains important information about operational issues that should be considered when using the MPLAB ICD 3 with your target design Release Notes for MPLAB ICD 3 In-Circuit Debugger For the latest information on using MPLAB ICD 3 in-circuit debugger, read the "Readme for MPLAB ICD 3 Debugger.htm" file (an HTML file) in the Readmes subdirectory of the MPLAB IDE installation directory. The release notes (Readme) contains update information and known issues that may not be included in this user's guide. Using MPLAB ICD 3 In-Circuit Debugger Poster (DS51765) This poster shows you how to hook up the hardware and install the software for the MPLAB ICD 3 in-circuit debugger using standard communications and a target board. MPLAB ICD 3 In-Circuit Debugger On-line Help File A comprehensive help file for the debugger is included with MPLAB IDE. Usage, troubleshooting and hardware specifications are covered. This may be more up-to-date than the printed documentation. Also, debugger reserved resources and limitations are listed for various devices. Header Board Specification (DS51292) This booklet describes how to install and use MPLAB ICD 3 in-circuit debugger headers. Headers are used to better debug selected devices using special -ICE device versions without the loss of pins or resources. Transition Socket Specification (DS51194) Consult this document for information on transition sockets available for use with MPLAB ICE 2000/4000 device adaptors, MPLAB ICD 2 headers and MPLAB ICD 3 in-circuit debugger headers. DS51766A-page 4 (c) 2008 Microchip Technology Inc. Preface THE MICROCHIP WEB SITE Microchip provides online support via our web site at www.microchip.com. This web site is used as a means to make files and information easily available to customers. Accessible by using your favorite Internet browser, the web site contains the following information: * Product Support - Data sheets and errata, application notes and sample programs, design resources, user's guides and hardware support documents, latest software releases and archived software * General Technical Support - Frequently Asked Questions (FAQs), technical support requests, online discussion groups, Microchip consultant program member listing * Business of Microchip - Product selector and ordering guides, latest Microchip press releases, listing of seminars and events, listings of Microchip sales offices, distributors and factory representatives DEVELOPMENT SYSTEMS CUSTOMER CHANGE NOTIFICATION SERVICE Microchip's customer notification service helps keep customers current on Microchip products. Subscribers will receive e-mail notification whenever there are changes, updates, revisions or errata related to a specified product family or development tool of interest. To register, access the Microchip web site at www.microchip.com, click on Customer Change Notification and follow the registration instructions. The Development Systems product group categories are: * Compilers - The latest information on Microchip C compilers, assemblers, linkers and other language tools. These include all MPLAB C compilers; all MPLAB assemblers (including MPASMTM assembler); all MPLAB linkers (including MPLINKTM object linker); and all MPLAB librarians (including MPLIBTM object librarian). * Emulators - The latest information on Microchip in-circuit emulators.These include the MPLAB REAL ICETM, MPLAB ICE 2000 and MPLAB ICE 4000 in-circuit emulators * In-Circuit Debuggers - The latest information on the Microchip in-circuit debuggers, the MPLAB ICD 2 in-circuit debugger and PICkitTM 2 debug express. * MPLAB(R) IDE - The latest information on Microchip MPLAB IDE, the Windows(R) Integrated Development Environment for development systems tools. This list is focused on the MPLAB IDE, MPLAB IDE Project Manager, MPLAB Editor and MPLAB SIM simulator, as well as general editing and debugging features. * Programmers - The latest information on Microchip programmers. These include the MPLAB PM3 and PRO MATE II device programmers and the PICSTART(R) Plus and PICkit 1 and 2 development programmers. (c) 2008 Microchip Technology Inc. DS51766A-page 5 MPLAB(R) ICD 3 In-Circuit Debugger User's Guide CUSTOMER SUPPORT Users of Microchip products can receive assistance through several channels: * * * * Distributor or Representative Local Sales Office Field Application Engineer (FAE) Technical Support Customers should contact their distributor, representative or field application engineer (FAE) for support. Local sales offices are also available to help customers. A listing of sales offices and locations is included in the back of this document. Technical support is available through the web site at: http://support.microchip.com. REVISION HISTORY Revision A (September 2008) This is the initial release of this document. DS51766A-page 6 (c) 2008 Microchip Technology Inc. MPLAB(R) ICD 3 IN-CIRCUIT DEBUGGER USER'S GUIDE Part 1 - Getting Started Chapter 1. Overview....................................................................................................... 9 Chapter 2. Theory of Operation .................................................................................. 13 Chapter 3. Installation.................................................................................................. 21 Chapter 4. General Setup ............................................................................................ 25 Chapter 5. Tutorial........................................................................................................ 29 (c) 2008 Microchip Technology Inc. DS51766A-page 7 MPLAB(R) ICD 3 In-Circuit Debugger User's Guide NOTES: DS51766A-page 8 (c) 2008 Microchip Technology Inc. MPLAB(R) ICD 3 IN-CIRCUIT DEBUGGER USER'S GUIDE Chapter 1. Overview 1.1 INTRODUCTION An overview of the MPLAB ICD 3 in-circuit debugger system is given. * * * * 1.2 MPLAB ICD 3 In-Circuit Debugger Defined How the MPLAB ICD 3 In-Circuit Debugger Helps You MPLAB ICD 3 In-Circuit Debugger Kit Components Device and Feature Support MPLAB ICD 3 IN-CIRCUIT DEBUGGER DEFINED The MPLAB ICD 3 in-circuit debugger is an in-circuit debugger that is controlled by a PC running MPLAB IDE (v8.15 or greater) software on a Windows(R) platform. The MPLAB ICD 3 in-circuit debugger is an integral part of the development engineer's toolsuite. The application usage can vary from software development to hardware integration. The MPLAB ICD 3 in-circuit debugger is a complex debugger system used for hardware and software development of Microchip PIC(R) microcontrollers (MCUs) and dsPIC(R) Digital Signal Controllers (DSCs) that are based on In-Circuit Serial ProgrammingTM (ICSPTM) and Enhanced In-Circuit Serial Programming 2-wire serial interfaces. The debugger system will execute code like an actual device because it uses a device with built-in emulation circuitry, instead of a special debugger chip, for emulation. All available features of a given device are accessible interactively, and can be set and modified by the MPLAB IDE interface. The MPLAB ICD 3 debugger was developed for emulating embedded processors with rich debug facilities which differ from conventional system processors in the following aspects: * Processors run at maximum speeds * Capability to incorporate I/O port data input In addition to debugger functions, the MPLAB ICD 3 in-circuit debugger system also may be used as a development programmer. (c) 2008 Microchip Technology Inc. DS51766A-page 9 MPLAB(R) ICD 3 In-Circuit Debugger User's Guide 1.3 HOW THE MPLAB ICD 3 IN-CIRCUIT DEBUGGER HELPS YOU The MPLAB ICD 3 in-circuit debugger system allows you to: * * * * * * * 1.4 Debug your application on your own hardware in real time Debug with hardware breakpoints Debug with software breakpoints Set breakpoints based on internal events Monitor internal file registers Emulate full speed Program your device MPLAB ICD 3 IN-CIRCUIT DEBUGGER KIT COMPONENTS The components of the MPLAB ICD 3 in-circuit debugger system kit are: 1. MPLAB ICD 3 with indicator lights 2. USB cable to provide communications between the debugger and a PC and to provide power to the debugger 3. Cable (also MPLAB ICD 2 compatible) to connect the MPLAB ICD 3 to a header module or target board 4. MPLAB IDE Quick Start Guide (DS51281) 5. CD-ROM with MPLAB IDE software and on-line documentation 6. ICD 3 Test Interface Board FIGURE 1-1: BASIC DEBUGGER SYSTEM Indicator Lights MPLAB(R) ICD 3 Modular Cable to Target Board or Header USB Cable to PC Additional hardware that may be ordered separately: * Transition socket * ICD headers * MPLAB processor extension kits DS51766A-page 10 (c) 2008 Microchip Technology Inc. Overview 1.5 DEVICE AND FEATURE SUPPORT Table 1-1 and Table 1-2 show the current and future support for devices and device features. TABLE 1-1: 32-BIT AND 16-BIT (DATA MEMORY) DEVICES PIC32MX dsPIC33F, PIC24F/H dsPIC30F SMPS(1) dsPIC30F Reset application C C C C Run, Halt C C C C Single Step C C C C Animate C C C C Full Speed Emulation C C C C Hardware Breakpoints C C C C Advanced Breakpoints C C C C Software Breakpoints N C C C Peripheral Freeze(2) C C C C Break on data fetch or write C C C C Break on Stack overflow C C C C Stopwatch C C C N Pass Counter C C C C WDT overflow C C C N Standard Speed Comm. C C C C Processor Pak N F F N Feature Legend: C = Current support D = Support dependent on device F = No support now, but planned in the future N = Support Not Available Note 1: Current Switch Mode Power Supply (SMPS) devices: dsPIC30F1010/2020/2023. 2: This feature operates differently depending on the selected device. (c) 2008 Microchip Technology Inc. DS51766A-page 11 MPLAB(R) ICD 3 In-Circuit Debugger User's Guide TABLE 1-2: 8-BIT (DATA MEMORY) DEVICES PIC18FXXJ PIC18F, PIC18F Enh, PIC18FXXK PIC12F, PIC16F Reset application C C C Run, Halt C C C Single Step C C C Animate C C C Full Speed Emulation C C C Hardware Breakpoints C C C Advanced Breakpoints C C N Software Breakpoints C C N Peripheral Freeze(1) C C C Break on data fetch or write C C N Break on Stack overflow C C N Stopwatch C N N Pass Counter C C N WDT overflow C N N Standard Speed Comm. C C C Processor Pak F F F Feature Legend: C = Current support F = No support now, but planned in the future N = Support Not Available Note 1: This feature operates differently depending on the selected device. DS51766A-page 12 (c) 2008 Microchip Technology Inc. MPLAB(R) ICD 3 IN-CIRCUIT DEBUGGER USER'S GUIDE Chapter 2. Theory of Operation 2.1 INTRODUCTION A simplified description of how the MPLAB ICD 3 in-circuit debugger system works is provided here. It is intended to provide enough information so a target board can be designed that is compatible with the debugger for both emulation and programming operations. The basic theory of in-circuit emulation and programming is described so that problems, if encountered, are quickly resolved. * MPLAB ICD 3 In-Circuit Debugger vs. MPLAB ICE 2000/4000 In-Circuit Emulators * MPLAB ICD 3 In-Circuit Debugger vs. MPLAB ICD 2 Debugger * Debugger To Target Communication * Communication Connections * Debugging with the Debugger * Requirements For Debugging * Programming with the Debugger * Resources Used by the Debugger 2.2 MPLAB ICD 3 IN-CIRCUIT DEBUGGER VS. MPLAB ICE 2000/4000 IN-CIRCUIT EMULATORS The MPLAB ICD 3 in-circuit debugger system is a next generation In-Circuit Debugger (ICD) system. It differs from classical in-circuit emulator systems (e.g., MPLAB ICE 2000/4000) in a single, but important way: the production device and emulation device are the same. This is a great benefit since differences (errata) between the production silicon and emulation silicon are eliminated. Additionally, as devices continue to operate at faster speeds, traditional emulator systems present bottlenecks caused by internal busses that must be carried off-chip to external memories and cannot offer full speed emulation. Another significant benefit is that there is no lead time between production silicon and emulation silicon. Further, a problem encountered on a production board can be easily debugged without having to install transition sockets and dealing with complicated cabling systems and setups to have access to the application. 2.3 MPLAB ICD 3 IN-CIRCUIT DEBUGGER VS. MPLAB ICD 2 DEBUGGER The MPLAB ICD 3 in-circuit debugger system is similar in function to the MPLAB ICD 2 in-circuit debugger system, but surpasses it in speed and functionality. The MPLAB ICD 3 also: * * * * * * Features USB high speed Is USB powered Is a hardware accelerator Provides a programmable voltage power supply Eliminates the RS-232 port Includes a diagnostic self-test interface board (c) 2008 Microchip Technology Inc. DS51766A-page 13 MPLAB(R) ICD 3 In-Circuit Debugger User's Guide 2.4 DEBUGGER TO TARGET COMMUNICATION The debugger system configurations are discussed in the following sections. CAUTION Do not connect the hardware before installing the software and USB drivers. Also, do not change hardware connections when the pod or target is powered. Standard ICSP Device Communication The debugger system can be configured to use standard ICSP communication for both programming and debugging functions. This 6-pin connection is the same one used by the MPLAB ICD 2 in-circuit debugger. The modular cable can be either (1) inserted into a matching socket at the target, where the target device is on the target board (Figure 2-1), or (2) inserted into a standard adapter/header board combo (available as a Processor Pak), which in then plugged into the target board (Figure 2-2). Note: Older header boards used a 6-pin (RJ-11) connector instead of an 8-pin connector, so these headers may be connected directly to the debugger. For more on standard communication, see Chapter 10. "Hardware Specification". FIGURE 2-1: STANDARD DEBUGGER SYSTEM - DEVICE WITH ON-BOARD ICE CIRCUITRY MPLAB(R) ICD 3 Target Device or PIM Target Board Power DS51766A-page 14 (c) 2008 Microchip Technology Inc. Theory of Operation FIGURE 2-2: STANDARD DEBUGGER SYSTEM - ICE DEVICE MPLAB(R) ICD 3 Processor Pak Standard Adapter Header Device-ICE OR ICD Header Transition Socket Device-ICE Target Board Power 2.5 COMMUNICATION CONNECTIONS 2.5.1 Standard Communication Target Connection Using the RJ-11 connector, the MPLAB ICD 3 in-circuit debugger is connected to the target device with the modular interface (six conductor) cable. The pin numbering for the connector is shown from the bottom of the target PC board in Figure 2-3. Note: Cable connections at the debugger and target are mirror images of each other, i.e., pin 1 on one end of the cable is connected to pin 6 on the other end of the cable. See Section 10.6.2.3 "Modular Cable Specification". FIGURE 2-3: STANDARD CONNECTION AT TARGET Target Connector VDD VPP/MCLR 2.5.2 PGD LVP 2 4 6 PGC 1 3 5 Target Vss PC Board Bottom Side Target Connection Circuitry Figure 2-4 shows the interconnections of the MPLAB ICD 3 in-circuit debugger to the connector on the target board. The diagram also shows the wiring from the connector to a device on the target PC board. A pull-up resistor (usually around 10 k) is recommended to be connected from the VPP/MCLR line to VDD so that the line may be strobed low to reset the device. (c) 2008 Microchip Technology Inc. DS51766A-page 15 MPLAB(R) ICD 3 In-Circuit Debugger User's Guide FIGURE 2-4: STANDARD CONNECTION TARGET CIRCUITRY User Reset Application PC Board VDD Device 4.7K-10K VPP/MCLR 1 PGC 5 PGD 4 VSS 3 AVDD AVSS 2.5.3 2 Interface Connector Target Powered In the following descriptions, only three lines are active and relevant to core debugger operation: pins 1 (VPP/MCLR), 5 (PGC) and 4 (PGD). Pins 2 (VDD) and 3 (VSS) are shown on Figure 2-4 for completeness. MPLAB ICD 3 has two configurations for powering the target device: internal debugger and external target power. The recommended source of power is external and derived from the target application. In this configuration, target VDD is sensed by the debugger to allow level translation for the target low voltage operation. If the debugger does not sense voltage on its VDD line (pin 2 of the interface connector), it will not operate. 2.5.4 Debugger Powered The internal debugger power is limited in two aspects: (1) the voltage range is not as wide (3-5V); and (2) the amount of current it can supply is limited to 100 mA. This may be of benefit for very small applications that have the device VDD separated from the rest of the application circuit for independent programming, but is not recommended for general usage as it imposes more current demands from the USB power system derived from the PC. Be aware that the target VDD is sensed by the debugger to allow level translation for target low-voltage operation. If the debugger does not sense voltage on its VDD line (pin 2 of the interface connector), it will not operate. Not all devices have the AVDD and AVSS lines, but if they are present on the target device, all must be connected to the appropriate levels in order for the debugger to operate. In general, it is recommended that all VDD/AVDD and VSS/AVSS lines be connected to the appropriate levels. Also, devices with a VCAP line (PIC18FXXJ for example) should be connected to the appropriate capacitor or level. Note: DS51766A-page 16 The interconnection is very simple. Any problems experienced are often caused by other connections or components on these critical lines that interfere with the operation of the MPLAB ICD 3 in-circuit debugger system, as discussed in the following section. (c) 2008 Microchip Technology Inc. Theory of Operation 2.5.5 Circuits That Will Prevent the Debugger From Functioning Figure 2-5 shows the active debugger lines with some components that will prevent the MPLAB ICD 3 in-circuit debugger system from functioning. FIGURE 2-5: IMPROPER CIRCUIT COMPONENTS 1 VPP/MCLR No! No! No! 5 PGC 4 PGD No! Interface Connector Specifically, these guidelines must be followed: * Do not use pull-ups on PGC/PGD - they will disrupt the voltage levels, since these lines have 4.7 k pull-down resistors in the debugger. * Do not use capacitors on PGC/PGD - they will prevent fast transitions on data and clock lines during programming and debug communications. * Do not use capacitors on MCLR - they will prevent fast transitions of VPP. A simple pull-up resistor is generally sufficient. * Do not use diodes on PGC/PGD - they will prevent bidirectional communication between the debugger and the target device. 2.6 DEBUGGING WITH THE DEBUGGER There are two steps to using the MPLAB ICD 3 in-circuit debugger system as a debugger. The first requires that an application be programmed into the target device. The second uses the internal in-circuit debug hardware of the target Flash device to run and test the application program. These two steps are directly related to the MPLAB IDE operations: 1. Programming the code into the target and activating special debug functions (see the next section for details). 2. Using the debugger to set breakpoints and run. If the target device cannot be programmed correctly, the MPLAB ICD 3 in-circuit debugger will not be able to debug. Figure 2-6 shows the basic interconnections required for programming. Note that this is the same as Figure 2-4, but for the sake of clarity, the VDD and VSS lines from the debugger are not shown. (c) 2008 Microchip Technology Inc. DS51766A-page 17 MPLAB(R) ICD 3 In-Circuit Debugger User's Guide FIGURE 2-6: PROPER CONNECTIONS FOR PROGRAMMING VDD Programming Voltage +5V 1 Internal Circuits 4.7 k 5 4 VPP/MCLR PGC PGD 4.7 k VSS A simplified diagram of some of the internal interface circuitry of the MPLAB ICD 3 in-circuit debugger is shown. For programming, no clock is needed on the target device, but power must be supplied. When programming, the debugger puts programming levels on VPP/MCLR, sends clock pulses on PGC and serial data via PGD. To verify that the part has been programmed correctly, clocks are sent to PGC and data is read back from PGD. This conforms to the ICSP protocol of the device under development. 2.7 REQUIREMENTS FOR DEBUGGING To debug (set breakpoints, see registers, etc.) with the MPLAB ICD 3 in-circuit debugger system, there are critical elements that must be working correctly: * The debugger must be connected to a PC. It must be powered by the PC via the USB cable, and it must be communicating with the MPLAB IDE software via the USB cable. See Chapter 3. "Installation" for details. * The debugger must be connected as shown to the VPP, PGC and PGD pins of the target device with the modular interface cable (or equivalent). VSS and VDD are also required to be connected between the debugger and target device. * The target device must have power and a functional, running oscillator. If the target device does not run, for any reason, the MPLAB ICD 3 in-circuit debugger cannot debug. * The target device must have its configuration words programmed correctly: - The oscillator Configuration bits should correspond to RC, XT, etc., depending upon the target design. - For some devices, the Watchdog Timer is enabled by default and needs to be disabled. - The target device must not have code protection enabled. - The target device must not have table read protection enabled. * LVP should be disabled. Once the above conditions are met, you may proceed to the following: * Sequence of Operations Leading to Debugging * Debugging Details 2.7.1 Sequence of Operations Leading to Debugging Given that the Requirements For Debugging are met, these actions can be performed when the MPLAB ICD 3 in-circuit debugger is set as the current debugger from the MPLAB IDE menu (Debugger>Select Tool>MPLAB ICD 3): * The application code is compiled/assembled by selecting Project>Build DS51766A-page 18 (c) 2008 Microchip Technology Inc. Theory of Operation Configuration>Debug. * When Debugger>Program is selected, the application code is programmed into the device's memory via the ICSP protocol as described above. * A small "debug executive" program is loaded into the high area of program memory of the target device. Since the debug executive must reside in program memory, the application program must not use this reserved space. Some devices have special memory areas dedicated to the debug executive. Check your device data sheet for details. * Special "in-circuit debug" registers in the target device are enabled. These allow the debug executive to be activated by the debugger. * The target device is held in Reset by keeping the VPP/MCLR line low. 2.7.2 Debugging Details Figure 2-7 illustrates the MPLAB ICD 3 in-circuit debugger system when it is ready for debugging. FIGURE 2-7: MPLAB(R) ICD 3 IN-CIRCUIT DEBUGGER READY FOR DEBUGGING VDD +12V 1 +5V VPP/MCLR Internal Circuits 4.7 k 4.7 k Internal Debug Registers Debug Executive PGC 5 Program Memory 4 Target must be Running for Debug Executive to Function Area Reserved for Debug Executive PGD Hardware Stack Shared by Debug Exec Area Used by Debug Exec File Registers Typically, in order to find out if an application program will run correctly, a breakpoint is set early in the program code. When a breakpoint is set from the user interface of MPLAB IDE, the address of the breakpoint is stored in the special internal debug registers of the target device. Commands on PGC and PGD communicate directly to these registers to set the breakpoint address. Next, the Debugger>Run function or the Run icon (forward arrow) is usually pressed from MPLAB IDE. The debugger will then tell the debug executive to run. The target will start from the Reset vector and execute until the Program Counter reaches the breakpoint address previously stored in the internal debug registers. After the instruction at the breakpoint address is executed, the in-circuit debug mechanism of the target device "fires" and transfers the device's Program Counter to the debug executive (much like an interrupt) and the user's application is effectively halted. The debugger communicates with the debug executive via PGC and PGD, gets the breakpoint status information and sends it back to MPLAB IDE. MPLAB IDE then sends a series of queries to the debugger to get information about the target device, such as file register contents and the state of the CPU. These queries are ultimately performed by the debug executive. (c) 2008 Microchip Technology Inc. DS51766A-page 19 MPLAB(R) ICD 3 In-Circuit Debugger User's Guide The debug executive runs just like an application in program memory. It uses some locations on the stack for its temporary variables. If the device does not run, for whatever reason, such as no oscillator, a faulty power supply connection, shorts on the target board, etc., then the debug executive cannot communicate to the MPLAB ICD 3 in-circuit debugger and MPLAB IDE will issue an error message. Another way to get a breakpoint is to press the MPLAB IDE's Halt button (the "pause" symbol to the right of the Run arrow). This toggles the PGC and PGD lines so that the in-circuit debug mechanism of the target device switches the Program Counter from the user's code in program memory to the debug executive. Again, the target application program is effectively halted, and MPLAB IDE uses the debugger communications with the debug executive to interrogate the state of the target device. 2.8 PROGRAMMING WITH THE DEBUGGER Use the MPLAB ICD 3 in-circuit debugger as a programmer to program an actual (non -ICE/-ICD) device, i.e., a device not on a header board. Select "MPLAB ICD 3" from Programmer>Select Programmer and compile/assemble your application code with the "Build Configuration" list box on the MPLAB IDE toolbar set to "Release". Also, it may be set by selecting Project>Build Configuration>Release. All debug features are turned off or removed when the debugger is used as a programmer. When using the Programmer>Program selection to program a device, MPLAB IDE will disable the in-circuit debug registers so the MPLAB ICD 3 in-circuit debugger will program only the target application code and the Configuration bits (and EEPROM data, if available and selected) into the target device. The debug executive will not be loaded. As a programmer, the debugger can only toggle the MCLR line to reset and start the target. A breakpoint cannot be set, and register contents cannot be seen or altered. The MPLAB ICD 3 in-circuit debugger system programs the target using ICSP. VPP, PGC and PGD lines should be connected as described previously. No clock is required while programming, and all modes of the processor can be programmed, including code protect, Watchdog Timer enabled and table read protect. 2.9 RESOURCES USED BY THE DEBUGGER For a complete list of resources used by the debugger for your device, please see the on-line help file in MPLAB IDE for the MPLAB ICD 3 in-circuit debugger. DS51766A-page 20 (c) 2008 Microchip Technology Inc. MPLAB(R) ICD 3 IN-CIRCUIT DEBUGGER USER'S GUIDE Chapter 3. Installation 3.1 INTRODUCTION How to install the MPLAB ICD 3 in-circuit debugger system is discussed. * * * * * 3.2 Installing the Software Installing the USB Device Drivers Connecting the Target Setting Up the Target Board Setting Up MPLAB IDE INSTALLING THE SOFTWARE To install the MPLAB IDE software, first acquire the latest MPLAB IDE installation executable (MPxxxxx.exe, where xxxxx represents the version of MPLAB IDE) from either the Microchip web site (www.microchip.com) or the MPLAB IDE CD-ROM (DS51123). Then run the executable and follow the screens to install MPLAB IDE. Note: 3.3 MPLAB IDE v8.15 or greater is required to use the MPLAB ICD 3 in-circuit debugger. INSTALLING THE USB DEVICE DRIVERS Installing MPLAB IDE will preinstall the USB device drivers for the MPLAB ICD 3 in-circuit debugger. Therefore, once you have installed MPLAB IDE, connect the debugger to the PC with a USB cable and follow the Windows "New Hardware Wizard" to automatically install the drivers. Expanded USB device driver installation instructions may found at: MPLAB IDE installation directory\ICD 3\Drivers\ddri.htm Note: (c) 2008 Microchip Technology Inc. If a new MPLAB ICD 3 is connected to your PC, you will need to reinstall the drivers for the new unit. DS51766A-page 21 MPLAB(R) ICD 3 In-Circuit Debugger User's Guide 3.4 CONNECTING THE TARGET A connection is built-in to select the type of communication with the target. See Section 2.4 "Debugger To Target Communication" for more details and a diagram. 1. Plug in the USB/power cable if not already connected. 2. Attach the communication cable(s) between debugger and target. FIGURE 3-1: INSERT COMMUNICATIONS AND USB/POWER CABLES MPLAB(R) ICD 3 Communications Cable 1 From Target 2 USB/Power From PC 3.5 SETTING UP THE TARGET BOARD The target must be set up for the type of target device to be used. 3.5.1 Using Production Devices For production devices, the debugger may be connected directly to the target board. The device on the target board must have built-in debug circuitry in order for the MPLAB ICD 3 in-circuit debugger to perform emulation with it. Consult the device data sheet to see if the device has the needed debug circuitry, i.e., it should have a "Background Debugger Enable" Configuration bit. Note: In the future, devices with circuitry that support ICD may be used. The target board must have a connector to accommodate the communications chosen for the debugger. For connection information, see Section 2.4 "Debugger To Target Communication", "Standard ICSP Device Communication". 3.5.2 Using ICE Devices For ICE devices, an ICE header board is required. The header board contains the hardware necessary to emulate a specific device or family of devices. For more information on ICE headers, see the "Header Board Specification" (DS51292). Note: DS51766A-page 22 In the future, ICD header boards with ICD devices (Device-ICD) may be used. (c) 2008 Microchip Technology Inc. Installation A transition socket is used with the ICE header to connect the header to the target board. Transition sockets are available in various styles to allow a common header to be connected to one of the supported surface mount package styles. For more information on transition sockets, see the "Transition Socket Specification" (DS51194). Header board layout will be different for headers or processor extension packs. For connection information, see Section 2.4 "Debugger To Target Communication", "Standard ICSP Device Communication". 3.5.3 Powering the Target There are a couple of configurations for powering MPLAB ICD 3 and the target. These are configuration essentials: * When using the USB connection, MPLAB ICD 3 can be powered from the PC but it can only provide a limited amount of current, up to 100 mA, at VDD from 3-5V to a small target board. * The desired method is for the target to provide VDD as it can provide a wider voltage range from 2-5V. The additional benefit is that plug-and-play target detection facility is inherited, i.e., MPLAB IDE will let you know in the Output window when it has detected the target and has detected the device. Note: The target voltage is only used for powering up the drivers for the ICSP interface; the target voltage does not power up the MPLAB ICD 3. The MPLAB ICD 3 system power is derived strictly from the USB port. If you have not already done so, connect the MPLAB ICD 3 to the target using the appropriate cables (see Section 3.4 "Connecting the Target"). Then power the target. If you are powering the target through the MPLAB ICD 3, see Section 9.5.8 "Settings Dialog, Power Tab" for instructions. 3.6 SETTING UP MPLAB IDE Once the hardware is connected and powered, MPLAB IDE may be set up for use with the MPLAB ICD 3 in-circuit debugger. On some devices, you must select the communications channel in the Configuration bits, e.g., PGC1/EMUC1 and PGD1/EMUD1. Make sure the pins selected here are the same ones physically connected to the device. For more on setting up a project and getting started with MPLAB ICD 3, see Chapter 4. "General Setup". To walk through the process of programming and debugging a device with the MPLAB ICD 3, see Chapter 5. "Tutorial". (c) 2008 Microchip Technology Inc. DS51766A-page 23 MPLAB(R) ICD 3 In-Circuit Debugger User's Guide NOTES: DS51766A-page 24 (c) 2008 Microchip Technology Inc. MPLAB(R) ICD 3 IN-CIRCUIT DEBUGGER USER'S GUIDE Chapter 4. General Setup 4.1 INTRODUCTION How to get started using the MPLAB ICD 3 in-circuit debugger is discussed. * * * * * * * 4.2 Starting the MPLAB IDE Software Creating a Project Viewing the Project Building the Project Setting Configuration Bits Setting the Debugger as the Debugger or Programmer Debugger/Programmer Limitations STARTING THE MPLAB IDE SOFTWARE After installing the MPLAB IDE software (Section 3.2 "Installing the Software"), invoke it by using any of these methods: * Select Start>Programs>Microchip>MPLAB IDE vx.xx>MPLAB IDE, where vx.xx is the version number. * Double click the MPLAB IDE desktop icon. * Execute the file mplab.exe in the \core subdirectory of the MPLAB IDE installation directory. For more information on using the software, see: * "MPLAB IDE User's Guide" (DS51519) - Comprehensive guide for using MPLAB IDE. * "MPLAB IDE Quick Start Guide" (DS51281) - Chapters 1 and 2 of the user's guide. * The on-line help files - Contains the most up-to-date information on MPLAB IDE and MPLAB ICD 3 in-circuit debugger. * Readme files - Last minute information on each release is included in Readme for MPLAB IDE.txt and Readme for MPLAB ICD 3 Debugger.txt. Both files are found in the Readmes subdirectory of the MPLAB IDE installation directory. (c) 2008 Microchip Technology Inc. DS51766A-page 25 MPLAB(R) ICD 3 In-Circuit Debugger User's Guide 4.3 CREATING A PROJECT The easiest way to create a new project is to select Project>Project Wizard. With the help of the Project Wizard, a new project and the language tools for building that project can be created. The wizard will guide you through the process of adding source files, libraries, linker scripts, etc., to the various "nodes" on the project window. See MPLAB IDE documentation for more detail on using this wizard. The basic steps are provided here: * * * * Select your device (e.g., PIC24FJ128GA010) Select a language toolsuite (e.g., Microchip C30 Toolsuite) Name the project Add application files (e.g., program.c, support.s, counter.asm) Note: 4.4 If you do not have a custom linker script in your project, the Project Manager will select the appropriate linker script for you. VIEWING THE PROJECT After the Project Wizard has created a project, the project and its associated files are visible in the Project window. Additional files can be added to the project using the Project window. Right click on any line in the project window tree to pop up a menu with additional options for adding and removing files. See MPLAB IDE documentation for more detail on using the Project window. 4.5 BUILDING THE PROJECT After the project is created, the application needs to be built. This will create object (hex) code for the application that can be programmed into the target by the MPLAB ICD 3 in-circuit debugger. To set build options, select Project>Build Options>Project. Note: On the Project Manager toolbar (View>Toolbars>Project Manager), select "Debug" from the drop-down list when using the MPLAB ICD 3 as a debugger, or select "Release" when using it as a programmer. When done, choose Project>Build All to build the project. DS51766A-page 26 (c) 2008 Microchip Technology Inc. General Setup 4.6 SETTING CONFIGURATION BITS Although device Configuration bits may be set in code, they also may be set in the MPLAB IDE Configuration window. Select Configure>Configuration Bits. By clicking on the text in the "Settings" column, these can be changed. Some Configuration bits of interest are: * Watchdog Timer Enable - On most devices, the Watchdog Timer is enabled initially. It is usually a good idea to disable this bit. * Comm Channel Select - For some devices, you will need to select the communcations channel for the device, e.g., PGC1/EMUC1 and PGD1/EMUD1. Make sure the pins selected here are the same ones physically connected to the device. * Oscillator - Select the configuration setting that matches the target oscillator. 4.7 SETTING THE DEBUGGER AS THE DEBUGGER OR PROGRAMMER Select Debugger>Select Tool>MPLAB ICD 3 to choose the MPLAB ICD 3 in-circuit debugger as the debug tool. The Debugger menu and MPLAB IDE toolbar will change to display debug options once the tool is selected. Also, the Output window will open and messages concerning MPLAB ICD 3 status and communications will be displayed on the MPLAB ICD 3 tab. For more information, see Section 9.2 "Debugging Functions" and Section 9.3 "Debugging Dialogs/Windows". Select Programmer>Select Programmer>MPLAB ICD 3 to choose the MPLAB ICD 3 in-circuit debugger as the programmer tool. The Programmer menu and MPLAB IDE toolbar will change to display programmer options once the tool is selected. Also, the Output window will open and messages concerning ICE status and communications will be displayed on the MPLAB ICD 3 tab. For more information, see Section 9.4 "Programming Functions". Select Debugger>Settings or Programmer>Settings to open the Settings dialog (Section 9.5 "Settings Dialog") and set up options as needed. If errors occurs, see: * Chapter 7. "Error Messages" * Chapter 6. "Frequently Asked Questions (FAQs)" * Section 10.7 "ICD 3 Test Interface Board" 4.8 DEBUGGER/PROGRAMMER LIMITATIONS For a complete list of debugger limitations for your device, please see the MPLAB ICD 3 on-line help file in MPLAB IDE by selecting Help>Topics>MPLAB ICD 3 and click OK. (c) 2008 Microchip Technology Inc. DS51766A-page 27 MPLAB(R) ICD 3 In-Circuit Debugger User's Guide NOTES: DS51766A-page 28 (c) 2008 Microchip Technology Inc. MPLAB(R) ICD 3 IN-CIRCUIT DEBUGGER USER'S GUIDE Chapter 5. Tutorial 5.1 INTRODUCTION This tutorial walks you through the process of developing a simple project using the sample programs counter.c and timer.c. This is an implementation of the PIC24FJ128GA010 device using the Explorer 16 Demo Board (DM240001). The program counter.c is a simple counting program. The incremental count, delayed by using Timer 1 (timer.c), is displayed via Port A on the demo board's LEDs. Topics covered in this chapter: * * * * * * * * * * * Setting Up the Environment and Selecting the Device Creating the Application Code Running the Project Wizard Viewing the Project Viewing Debug Options Setting Up the Demo Board Setting Up the Demo Board Loading Program Code For Debugging Running Debug Code Debugging Code Using Breakpoints Programming the Application (c) 2008 Microchip Technology Inc. DS51766A-page 29 MPLAB(R) ICD 3 In-Circuit Debugger User's Guide 5.2 SETTING UP THE ENVIRONMENT AND SELECTING THE DEVICE Before beginning this tutorial, follow the steps in Chapter 3. "Installation" to set up the MPLAB IDE software and MPLAB ICD 3 system hardware. Double click on the MPLAB IDE icon to launch the application. Once launched, the MPLAB IDE desktop should appear. FIGURE 5-1: MPLAB(R) IDE DESKTOP Selecting the Device To select the device for this tutorial: 1. Select Configure>Select Device. 2. In the Device Selection dialog, choose "PIC24FJ128GA010" from the Device list box. The light icon next to "MPLAB ICD 3" in the "Microchip Tool Programmer/Debugger Tool Support" sections should be green. 3. Click OK. 5.3 CREATING THE APPLICATION CODE For this tutorial, two C programs (counter.c and timer.c) will be used. The code for each is shown below. 1. Using Windows(R) Explorer, create a project folder and directory, for example, C:\Projects\ICD3Tut. 2. Open an editor window by selecting File>New. Enter the code for the first program (see text for counter.c) in this window and save to the project\directory folder. 3. Open another editor window by selecting File>New. Enter the code for the second program (see text for timer.c) in this window and save to the project\directory folder. DS51766A-page 30 (c) 2008 Microchip Technology Inc. Tutorial counter.c /***************************************************************************** * MPLAB ICD 3 In-Circuit Debugger Tutorial * Counting program * ***************************************************************************** * Demo Board: Explorer 16 * Processor: PIC24FJ128GA010 * Compiler: MPLAB C30 * Linker: MPLAB LINK30 * Company: Microchip Technology Incorporated * *****************************************************************************/ #include "p24FJ128GA010.h" // Set up configuration bits _CONFIG1( JTAGEN_OFF & GCP_OFF & GWRP_OFF & COE_OFF & FWDTEN_OFF & ICS_PGx2) _CONFIG2( FCKSM_CSDCMD & OSCIOFNC_ON & POSCMOD_HS & FNOSC_PRI ) void TimerInit(void); unsigned char TimerIsOverflowEvent(void); // Set up user-defined variables #define INIT_COUNT 0 unsigned int counter; int main(void) { // Set up PortA IOs as digital output AD1PCFG = 0xffff; TRISA = 0x0000; // Set up Timer1 TimerInit(); // Initialize variables counter = INIT_COUNT; while (1) { // Wait for Timer1 overflow if (TimerIsOverflowEvent()){ counter++; //increment counter PORTA = counter; //display on port LEDs }// End of if... }// End of while loop... }// End of main()... (c) 2008 Microchip Technology Inc. DS51766A-page 31 MPLAB(R) ICD 3 In-Circuit Debugger User's Guide timer.c /***************************************************************************** * MPLAB ICD 3 In-Circuit Debugger Tutorial * Timer program * ***************************************************************************** * Demo Board: Explorer 16 * Processor: PIC24FJ128GA010 * Compiler: MPLAB C30 * Linker: MPLAB LINK30 * Company: Microchip Technology Incorporated * *****************************************************************************/ #include "p24FJ128GA010.h" //declare functions extern void TimerInit(void); extern unsigned char TimerIsOverflowEvent(void); /********************************************************************* * Function: TimerInit * * PreCondition: None. * * Input: None. * * Output: None. * * Overview: Initializes Timer1 for use. * ********************************************************************/ void TimerInit(void) { PR1 = 0xFFFF; IPC0bits.T1IP = 5; T1CON = 0b1000000000010000; IFS0bits.T1IF = 0; } /********************************************************************* * Function: TimerIsOverflowEvent * * PreCondition: None. * * Input: None. * * Output: Status. * * Overview: Checks for an overflow event, returns TRUE if * an overflow occured. * * Note: This function should be checked at least twice * per overflow period. ********************************************************************/ unsigned char TimerIsOverflowEvent(void) { if (IFS0bits.T1IF) { DS51766A-page 32 (c) 2008 Microchip Technology Inc. Tutorial IFS0bits.T1IF = 0; TMR1 = 0; return(1); } return(0); } /********************************************************************* * EOF ********************************************************************/ 5.4 RUNNING THE PROJECT WIZARD The MPLAB C30 C compiler will be used in this project. You may either purchase the full compiler or download a free student version from the Microchip website. 1. To set up this project, select Project>Project Wizard. A Welcome screen will appear. 2. Proceed to the second dialog of the wizard. The PIC24FJ128GA010 should be selected. 3. Proceed to the next dialog of the wizard to set up the language tools. In the "Active Toolsuite" pull-down, select "Microchip C30 Toolsuite." Make sure that the tools are set to the proper executables, by default located in the directory C:\Program Files\Microchip\MPLAB C30\bin. MPLAB C30 should be pointing to pic30-gcc.exe and MPLAB LINK30 should be pointing to pic30-ld.exe. FIGURE 5-2: PROJECT WIZARD - TOOLSUITE SELECTION 4. Proceed to the next dialog of the wizard to give a name and location to your project. You may Browse to find a location. (c) 2008 Microchip Technology Inc. DS51766A-page 33 MPLAB(R) ICD 3 In-Circuit Debugger User's Guide FIGURE 5-3: PROJECT WIZARD - PROJECT NAME 5. Proceed to the next dialog of the wizard where project files can be added. Files can also be added later if something is missed. For this example, browse to your project directory to find both files. Click on counter.c to highlight it and then click on ADD>> to add it to the right pane. Click on timer.c to highlight it and then click on ADD>> to add it to the right pane. Leave the "A" next to the file name. For more information on what this and other letters mean, click the Help button on the dialog. FIGURE 5-4: PROJECT WIZARD - ADD FILES 6. Proceed to the Summary screen. If you have made any errors, click Configuration Bits and unchecking "Configuration bits set in code". Do not change any values for this tutorial. FIGURE 5-6: 5.6.2 CONFIGURATION BITS WINDOW Selecting the Debugger as a Debugger To select MPLAB ICD 3 in-circuit debugger as a debugger, select Debugger>Select Tool>ICD 3. Then: 1. The Output window will open to display connection information. Depending on the version of MPLAB IDE or the device selected, a message box may appear indicating that the firmware needs to be updated. Select OK in the message box to allow MPLAB IDE to install the new firmware. Also, since different MPLAB ICD 3 firmware is used for different families of devices, this message box may appear when switching to a different device. 2. The Output window will display information about the firmware update and will shen when the MPLAB ICD 3 is connected to the target. 3. The Debugger menu will show available debugger debug options. 4. A Debug toolbar will appear. Mouse over a button to see a pop-up of its function. 5.6.3 Programming Options To set program options, select Debugger>Settings and click on the Program Memory tab. DS51766A-page 36 (c) 2008 Microchip Technology Inc. Tutorial FIGURE 5-7: DEBUGGER PROGRAM MEMORY TAB Here you may allow the debugger to automatically choose the programming ranges (recommended) or you may select ranges manually. * The "Memories" section should have "Program" checked, and "EEPROM" and "ID" unchecked. When using the MPLAB ICD 3 in-circuit debugger as a debugger, Configuration bits will always be programmed and the "Configuration" box will be checked and grayed out. * For the PIC24FJ devices, all memory will be erased each time the chip is programmed. Therefore, in the "Program Options" section, "Erase all before Program" will have no effect. * The "Program Memory" addresses ("Start" and "End" address) set the range of program memory that will be read, programmed or verified. When debugging code, you will frequently repeat the edit, rebuild, reprogram and run sequence. To automate this, there are checkboxes "Program after successful build" and "Run after successful program". Leave these unchecked for now. 5.7 CREATING A HEX FILE To create a hex file for debugging: * On the Project toolbar, select "Debug" from the Build Configuration drop-down list. * Select Project>Build All or right click on the project name in the project window and select "Build All" from the popup menu. The project will build (Figure 5-8), and the resulting .hex file will have the same name as the project (Figure 5-9). The hex file is the code that will be programmed into the target device. Note: (c) 2008 Microchip Technology Inc. Depending on the build options selected, your Output window may look different from Figure 5-8 (Project>Build Options>Project, MPLAB C30 and MPLAB LINK30 tabs.) DS51766A-page 37 MPLAB(R) ICD 3 In-Circuit Debugger User's Guide DS51766A-page 38 FIGURE 5-8: OUTPUT WINDOW FIGURE 5-9: WINDOWS EXPLORER - PROJECT FILES (c) 2008 Microchip Technology Inc. Tutorial 5.8 SETTING UP THE DEMO BOARD Before beginning to debug, make sure the Explorer 16 Demo Board is set up properly. For more information, see the "Explorer 16 Development Board User's Guide" (DS51589). Settings for this tutorial should be as follows: * PIC24FJ128GA010 PIM (Plug-In Module) plugged into the board. * S2: "PIM" selected; "PIC" selection for devices soldered onto the board. * J7: "PIC24" selected; the debugger will communicate directly with the PIC24FJ128GA010 and not the on-board PIC18LF4550 USB device. * JP2: LEDs have been enabled by connecting Jumper 2. * D1 on: Power being supplied to board. 5.9 LOADING PROGRAM CODE FOR DEBUGGING Select Debugger>Program to program RITut.hex into the PIC24FJ128GA010 on the Explorer 16 demo board. Note: The debug executive code is automatically programmed in upper program memory for MPLAB ICD 3 debug functions. Debug code must be programmed into the target device to use the in-circuit debugging capabilities of the MPLAB ICD 3 in-circuit debugger. During programming, the ICD 3 tab of the Output dialog shows the current phase of operation. When programming is complete, the dialog should look similar to Figure 5-10. FIGURE 5-10: Note: (c) 2008 Microchip Technology Inc. OUTPUT WINDOW - MPLAB(R) ICD 3 TAB If you have trouble programming your device or communicating with the debugger, unplug the Explorer 16 board and use the self-test board (Section 10.7 "ICD 3 Test Interface Board") to verify communications. For additional help, see Chapter 6. "Frequently Asked Questions (FAQs)". DS51766A-page 39 MPLAB(R) ICD 3 In-Circuit Debugger User's Guide 5.10 RUNNING DEBUG CODE The MPLAB ICD 3 in-circuit debugger executes in Real Time or in Step mode. * Real Time execution occurs when the device is put in the MPLAB IDE's Run mode. * Step mode execution can be accessed after the processor is halted. These toolbar buttons can be used for quick access to commonly-used debug operations. Debugger Menu Run Halt Animate Step Into Step Over Step Out Reset Toolbar Buttons Begin in Real-Time mode: 1. Open the source files counter.c and timer.c (double click on the file names in the Project window or use File>Open). 2. Select Debugger>Run (or click the Run toolbar button). 3. Observe the LEDs. They will be counting up in binary. 4. Select Debugger>Halt (or click the Halt toolbar button) to stop the program execution. 5. When the debugger halts, one of the open source code windows will pop to the front and a green arrow will indicate where the program halted. To use Step mode: 1. Select Debugger>Step Into (or click the Step Into toolbar button) to execute one instruction and then halt. The green arrow in the code listing will move accordingly. 2. Repeat as needed. The step functions "Step Over" and "Step Out" are used with functions and discussed in the MPLAB IDE documentation. 5.11 DEBUGGING CODE USING BREAKPOINTS The example code in this tutorial has already been debugged and works as expected. However, this code is still useful to demonstrate the debugging features of the MPLAB ICD 3 in-circuit debugger. The first debug feature to be discussed are breakpoints. Breakpoints stop code execution at a selected line of code. * Setting Software Breakpoints 5.11.1 Choosing a Breakpoint Type For the device used in this tutorial, you have the choice of using either hardware or software breakpoints. To set breakpoint options, select Debugger>Settings and click on the Configuration tab. Select the type of breakpoint that best suits your application needs. For this tutorial, we will begin using the default breakpoint type (hardware breakpoints.) DS51766A-page 40 (c) 2008 Microchip Technology Inc. Tutorial 5.11.2 Setting a Single Hardware Breakpoint To set a single breakpoint: 1. Select Debugger>Reset>Processor Reset (or click the Reset toolbar button) to reset the example program. 2. Highlight or place the cursor on the following line of code from counter.c: counter++; //increment counter 3. Double click on the line, or right click on the line and then select Set Breakpoint from the shortcut menu. This line is now marked as a breakpoint (B in red stop sign) as shown in Figure 5-11. FIGURE 5-11: SET BREAKPOINT 4. Select Debugger>Run (or click the Run toolbar button) to run the program once again in Real-Time mode. The program will halt at the line marked by the breakpoint, but now there will be a green arrow over the breakpoint symbol. FIGURE 5-12: (c) 2008 Microchip Technology Inc. PROGRAM HALTED DS51766A-page 41 MPLAB(R) ICD 3 In-Circuit Debugger User's Guide 5. Open a new Watch window to watch the counter variable change value as the program executes. Select View>Watch. The Watch dialog opens with the Watch 1 tab selected. Select "counter" from the list next to Add Symbol, and then click the button. counter is added to the Watch window. Select "PORTA" from the list next to Add SFR, and then click the button. PORTA is added to the Watch window. The selected symbols should now be visible in the Watch window as shown in Figure 5-13. FIGURE 5-13: WATCH WINDOW 6. Select Debugger>Run (or click the Run toolbar button) to run the program once again. The program will halt at the breakpoint and you will notice that the value of both variables has incremented by 1. 7. Run again as desired to see the values increase. When done, use Debugger>Reset>Processor Reset (or click the Reset toolbar button) to reset the processor. 5.11.3 Setting Multiple Hardware Breakpoints To set multiple breakpoints, either set numerous single breakpoints as specified in the previous section, or use the Breakpoints dialog (see Section 9.3.1 "Breakpoints Dialog"). The Breakpoints dialog also allows you to control breakpoint interaction. Note: If you exceed the maximum allowed number of breakpoints for your device, MPLAB IDE will warn you. 1. Select Debugger>Breakpoints to open the Breakpoints dialog. The breakpoint set in the previous section will be displayed in this dialog. Click the Add Breakpoint button to add another breakpoint. 2. On the Program Memory tab of the Set Breakpoint dialog, enter "2e6" as the hex Address and click OK. FIGURE 5-14: DS51766A-page 42 SET BREAKPOINTS DIALOG (c) 2008 Microchip Technology Inc. Tutorial The additional breakpoint will appear below the previous breakpoint in the Breakpoints dialog and also as a breakpoint symbol next to the following line of code: PORTA = counter; //display on port LEDs The breakpoint symbol is yellow in this case because it was set based on an address. FIGURE 5-15: TWO BREAKPOINTS 3. Run the program to see it halt at the first breakpoint. The values in the Watch window will not change. Then run again to see it stop at the second breakpoint. (The program may skid past this breakpoint.) Now the values in the Watch window will change. 5.11.4 Using the Stopwatch with Breakpoints To determine the time between the breakpoints, use the Stopwatch. 1. Click Stopwatch (on the Breakpoints dialog) to open the Stopwatch dialog. FIGURE 5-16: (c) 2008 Microchip Technology Inc. STOPWATCH DIALOG DS51766A-page 43 MPLAB(R) ICD 3 In-Circuit Debugger User's Guide 2. Under "Start Condition", select the first breakpoint from the list. Then uncheck "Start condition will cause the target device to halt". 3. Under "Stop Condition", select the second breakpoint from the list. Then check "Stop condition will cause the target device to halt". 4. Check "Reset stopwatch on run". 5. Click OK. FIGURE 5-17: STOPWATCH DIALOG 6. Run the program until it halts. In the Output window, on the ICD 3 tab, the number of cycles between the two instructions should be shown as: Stopwatch cycle count = 4(decimal) 7. Clear both breakpoints from the code by deleting them from the Breakpoints dialog, double clicking on each line to remove them, or right clicking on each line and selecting "Remove Breakpoint". You can also right click and select Breakpoints>Remove All Breakpoints to remove both at once. 5.11.5 Setting Software Breakpoints To change the breakpoint type from hardware to software: * Select Debugger>Settings and click on the Configuration tab. * Click the radio button next to "Use Software Breakpoints". * Click OK. You will now use software breakpoints instead of the hardware breakpoints used previously. Note: Using software breakpoints for debug impacts device endurance. Therefore, it is recommended that devices used in this manner not be used as production parts. 1. To set a single software breakpoint, follow the instructions in Section 5.11.2 "Setting a Single Hardware Breakpoint". - When you set a software breakpoint, you will see the following in the Output window: Programming software breakpoint(s)... Software breakpoint(s) set. - If you have already set a hardware breakpoint in this tutorial, the variables will already be added to the Watch window for use with the software breakpoint. DS51766A-page 44 (c) 2008 Microchip Technology Inc. Tutorial 2. To set multiple software breakpoints, follow the instructions in Section 5.11.3 "Setting Multiple Hardware Breakpoints". - There is no breakpoint skidding with software breakpoints, i.e., the program halts on the breakpoint. This may affect how you see values change in the Watch window. - There is a maximum number of breakpoints with software breakpoints, i.e, although this tutorial only uses two, the number of software breakpoints is 999. 3. The stopwatch is meant to be used with hardware breakpoints. However, you can use the stopwatch with software breakpoints, but they will be converted to hardware breakpoints as you select them. In the Output window, you will see: Converting breakpoint types... Breakpoint type conversion complete. Follow the steps as specified in Section 5.11.4 "Using the Stopwatch with Breakpoints". 4. Set the breakpoints to hardware again for the remainder of the tutorial. Select Debugger>Settings, click on the Configuration tab, click the radio button next to "Use Hardware Breakpoints" and then click OK. 5.12 PROGRAMMING THE APPLICATION When the program is successfully debugged and running, the next step is to program the device for stand-alone operation in the finished design. When doing this, the resources reserved for debug are released for use by the application. To program the application follow these steps: 1. Disable the MPLAB ICD 3 in-circuit debugger as the debug tool by selecting Debugger>Select Tool>None. 2. Enable the MPLAB ICD 3 in-circuit debugger as the programmer by selecting Programmer>Select Programmer>ICD 3. 3. Optional: Set up the ID in Configure>ID Memory (for devices that support ID memory.) 4. Set up the parameters for programming on the Programmer>Settings, Program Memory tab. 5. On the Project toolbar, select "Release" from the Build Configuration drop-down list. Then select Project>Build All. 6. Select Programmer>Program. The application should now be running on its own. Press the Reset (MCLR) button on the demo board to restart the count. You can modify the program code to wait for a button press before beginning or to terminate the program. Modifying the program will require you to select the debugger as a debug tool. 1. Disable the MPLAB ICD 3 in-circuit debugger as the programmer by selecting Programmer>Select Programmer>None. 2. Enable the MPLAB ICD 3 in-circuit debugger as the debug tool by selecting Debugger>Select Tool>ICD 3. 3. Edit the counter.c code as desired. (This is left as an exercise for you.) 4. On the Project toolbar, select "Debug" from the Build Configuration drop-down list. Then select Project>Build All. 5. Select Debugger>Program. 6. Run, step and debug your program as required. (c) 2008 Microchip Technology Inc. DS51766A-page 45 MPLAB(R) ICD 3 In-Circuit Debugger User's Guide NOTES: DS51766A-page 46 (c) 2008 Microchip Technology Inc. MPLAB(R) ICD 3 IN-CIRCUIT DEBUGGER USER'S GUIDE Part 2 - Troubleshooting Chapter 6. Frequently Asked Questions (FAQs) ....................................................... 49 Chapter 7. Error Messages.......................................................................................... 53 (c) 2008 Microchip Technology Inc. DS51766A-page 47 MPLAB(R) ICD 3 In-Circuit Debugger User's Guide NOTES: DS51766A-page 48 (c) 2008 Microchip Technology Inc. MPLAB(R) ICD 3 IN-CIRCUIT DEBUGGER USER'S GUIDE Chapter 6. Frequently Asked Questions (FAQs) 6.1 INTRODUCTION Look here for answers to frequently asked questions about the MPLAB ICD 3 in-circuit debugger system. * How Does It Work * What's Wrong 6.2 HOW DOES IT WORK * What's in the silicon that allows it to communicate with the MPLAB ICD 3 in-circuit debugger? MPLAB ICD 3 in-circuit debugger can communicate with Flash silicon via the ICSP interface. It uses the debug executive located in test memory. * How is the throughput of the processor affected by having to run the debug executive? * The debug executive doesn't run while in Run mode, so there is no throughput reduction when running your code, i.e., the debugger doesn't `steal' any cycles from the target device. How does the MPLAB ICD 3 in-circuit debugger compare with other in-circuit emulators/debuggers? Please refer to Section 2.2 "MPLAB ICD 3 In-Circuit Debugger vs. MPLAB ICE 2000/4000 In-Circuit Emulators" and Section 2.3 "MPLAB ICD 3 In-Circuit Debugger vs. MPLAB ICD 2 Debugger". * How does MPLAB IDE interface with the MPLAB ICD 3 in-circuit debugger to allow more features than MPLAB ICD 2? MPLAB ICD 3 in-circuit debugger communicates using the debug executive located in the test area. The debug exec is streamlined for more efficient communication. The debugger contains an FPGA, large SRAM Buffers (1Mx8) and a High Speed USB interface. Program memory image is downloaded and is contained in the SRAM to allow faster programming. The FPGA in the debugger serves as an accelerator for interfacing with the device in-circuit debugger modules. * On the MPLAB ICE 2000/4000 debuggers, the data must come out on the bus in order to perform a complex trigger on that data. Is this also required on the MPLAB ICD 3 in-circuit debugger? For example, could I halt based on a flag going high? The MPLAB ICE 2000/4000 debuggers use a special debugger chip (-ME) for monitoring. There is no -ME with the MPLAB ICD 3 in-circuit debugger so there are no busses to monitor externally. With the MPLAB ICD 3 in-circuit debugger, rather than using external breakpoints, the built-in breakpoint circuitry of the debug engine is used - the busses and breakpoint logic are monitored inside the part. (c) 2008 Microchip Technology Inc. DS51766A-page 49 MPLAB(R) ICD 3 In-Circuit Debugger User's Guide * Does the MPLAB ICD 3 in-circuit debugger have complex breakpoints like MPLAB ICE 2000/4000? Yes. You can break based on a value in a data memory location. You can also do sequenced breakpoints, where several events are happening before it breaks, but you can only do 2 sequences instead of 4, as you can in the MPLAB ICE 2000. You can also do the AND condition and do PASS counts. See Section 9.3.1 "Breakpoints Dialog" for more information. * Are any of the driver boards optoisolated or electrically isolated? They are DC optoisolated, but not AC optoisolated. You cannot apply a floating or high voltage (120V) to the current system. * What limitations are there with the standard cable? The standard ICSP RJ-11 cable does not allow for clock speeds greater than about 15 Mb/sec. dsPIC33F DSCs running at full speed are greater than the 15 Mb/sec limit. * Will this slow down the running of the program? There is no cycle stealing with the MPLAB ICD 3 in-circuit debugger. The output of data is performed by the state machine in the silicon. * Is it possible to debug a dsPIC DSC running at any speed? The MPLAB ICD 3 is capable of debugging at any device speed as specified in the device's data sheet. * What is the function of pin 6, the LVP pin? Pin 6 is reserved for the LVP (Low-Voltage Programming) connection. 6.3 WHAT'S WRONG * My PC went into power-down/hibernate mode, and now my debugger won't work. What happened? When using the debugger for prolonged periods of time, and especially as a debugger, be sure to disable the Hibernate mode in the Power Options Dialog window of your PC's operating system. Go to the Hibernate tab and clear or uncheck the "Enable hibernation" check box. This will ensure that all communication is maintained across all the USB subsystem components. * I set my peripheral to NOT freeze on halt, but it is suddenly freezing. What's going on? For dsPIC30F/33F and PIC24F/H devices, a reserved bit in the peripheral control register (usually either bit 14 or 5) is used as a Freeze bit by the debugger. If you have performed a write to the entire register, you may have overwritten this bit. (The bit is user-accessible in Debug mode.) To avoid this problem, write only to the bits you wish to change for your application (BTS, BTC) instead of to the entire register (MOV). DS51766A-page 50 (c) 2008 Microchip Technology Inc. Frequently Asked Questions (FAQs) * When using a 16-bit device, an unexpected reset occurred. How do I determine what caused it? Some things to consider: - To determine a reset source, check the RCON register. - Handle traps/interrupts in an Interrupt Service Routine (ISR). You should include trap.c style code, i.e., void __attribute__((__interrupt__)) _OscillatorFail(void); : void __attribute__((__interrupt__)) _AltOscillatorFail(void); : void __attribute__((__interrupt__)) _OscillatorFail(void) { INTCON1bits.OSCFAIL = 0; //Clear the trap flag while (1); } : void __attribute__((__interrupt__)) _AltOscillatorFail(void) { INTCON1bits.OSCFAIL = 0; while (1); } : - Use ASSERTs. * I have finished debugging my code. Now I've programmed my part, but it won't run. What's wrong? Some things to consider are: - Have you selected the debugger as a programmer and then tried to program a header board? A header board contains an -ICE/-ICD version of the device and may not function like the actual device. Only program regular devices with the debugger as a programmer. Regular devices include devices that have on-board ICE/ICD circuitry, but are not the special -ICE/-ICD devices found on header boards. - Have you selected the debugger as a debugger and then tried to program a production device? Programming a device when the debugger is a debugger will program a debug executive into program memory and set up other device features for debug (see Section 2.7.1 "Sequence of Operations Leading to Debugging"). To program final (release) code, select the debugger as a programmer. - Have you selected "Release" from the Build Configuration drop-down list or Project menu? You must do this for final (release) code. Rebuild your project, reprogram the device, and try to run your code again. * I didn't set a software breakpoint, yet I have one in my code. What's going on? What you are seeing is a phantom breakpoint. Occasionally, a breakpoint can become enabled when it shouldn't be. Simply disable or delete the breakpoint. (c) 2008 Microchip Technology Inc. DS51766A-page 51 MPLAB(R) ICD 3 In-Circuit Debugger User's Guide * I don't see my problem here. Now what? Try the following resources: - Chapter 10. "Limitations" - Section 2.9 "Resources Used by the Debugger" - Section 7.2 "Specific Error Messages" - Section 7.3 "General Corrective Actions" DS51766A-page 52 (c) 2008 Microchip Technology Inc. MPLAB(R) ICD 3 IN-CIRCUIT DEBUGGER USER'S GUIDE Chapter 7. Error Messages 7.1 INTRODUCTION The MPLAB ICD 3 in-circuit debugger produces many different error messages; some are specific and others can be resolved with general corrective actions. * Specific Error Messages * General Corrective Actions 7.2 SPECIFIC ERROR MESSAGES MPLAB ICD 3 in-circuit debugger error messages are listed below in numeric order. Note: Numbers may not yet appear in displayed messages. Use the Search tab on the Help viewer to find your message and highlight it below. Text in error messages listed below of the form %x (a variable) will display as text relevant to your particular situation in the actual error message. ICD3Err0001: Failed while writing to program memory. ICD3Err0002: Failed while writing to EEPROM. ICD3Err0003: Failed while writing to configuration memory. See Section 7.3.1 "Read/Write Error Actions". ICD3Err0005: ICD 3 is currently busy and cannot be unloaded at this time. If you receive this error when attempting to deselect the debugger as a debugger or programmer: 1. Wait - give the debugger time to finish any application tasks. Then try to deselect the debugger again. 2. Select Halt to stop any running applications. Then try to deselect the debugger again. 3. Unplug the debugger from the PC. Then try to deselect the debugger again. 4. Shut down MPLAB IDE. ICD3Err0006: Failed while writing to user ID memory. ICD3Err0007: Failed while reading program memory. ICD3Err0008: Failed while reading EEPROM. ICD3Err0009: Failed while reading configuration memory. ICD3Err0010: Failed while reading user ID memory. See Section 7.3.1 "Read/Write Error Actions". ICD3Err0011: Bulk erase failed. See Section 7.3.1 "Read/Write Error Actions". If these do not work, try another device. (c) 2008 Microchip Technology Inc. DS51766A-page 53 MPLAB(R) ICD 3 In-Circuit Debugger User's Guide ICD3Err0012: Download debug exec failed If you receive this error while attempting to program from the Debugger menu: 1. 2. 3. 4. Deselect the debugger as the debug tool. Close your project and then close MPLAB IDE. Restart MPLAB IDE and re-open your project. Reselect the debugger as your debug tool and attempt to program your target device again. If this does not work, see Section 7.3.4 "Corrupted Installation Actions". ICD3Err0013: NMMR register write failed. ICD3Err0014: File register write failed. See Section 7.3.2 "Debugger-to-Target Communication Error Actions". ICD3Err0015: Data transfer was unsuccessful. %d byte(s) expected, %d byte(s) transferred. See Section 7.3.3 "Debugger-to-PC Communication Error Actions". ICD3Err0016: Cannot transmit. ICD 3 not found. The debugger is not connected to the PC. ICD3Err0017: File register read failed. ICD3Err0018: NMMR register read failed. ICD3Err0019: Failed while reading emulation registers. ICD3Err0020: Failed while writing emulation registers. See Section 7.3.2 "Debugger-to-Target Communication Error Actions". ICD3Err0021: Command not echoed properly. Sent %x, received %x. ICD3Err0022: Failed to get ICD 3 version information. ICD3Err0023: Download FPGA failed. ICD3Err0024: Download RS failed. ICD3Err0025: Download AP failed. See Section 7.3.3 "Debugger-to-PC Communication Error Actions". ICD3Err0026: Download program exec failed. If you receive this error while attempting to program from the Debugger menu: 1. 2. 3. 4. Deselect the debugger as the debug tool. Close your project and then close MPLAB IDE. Restart MPLAB IDE and re-open your project. Reselect the debugger as your debug tool and attempt to program your target device again. If this does not work, see Section 7.3.4 "Corrupted Installation Actions". ICD3Err0027: Bulk transfer failed due to invalid checksum See Section 7.3.3 "Debugger-to-PC Communication Error Actions". Also, ensure that the cables used are the correct length. ICD3Err0028: Download device database failed If you receive this error: 1. Try downloading again. It may be a one-time error. 2. Try manually downloading. Select Debugger>Settings, Configuration tab, and click Manual Download. Select the highest number .jam file and click Open. ICD3Err0029: Communication failure. Unexpected command echo response %x received from ICD 3. See Section 7.3.3 "Debugger-to-PC Communication Error Actions". DS51766A-page 54 (c) 2008 Microchip Technology Inc. Error Messages ICD3Err0030: Unable to read/find firmware File %s. If the Hex file exists: * Reconnect and try again. * If this does not work, the file may be corrupted. Reinstall MPLAB IDE. If the Hex file does not exist: * Reinstall MPLAB IDE. ICD3Err0031: Failed to get PC. ICD3Err0032: Failed to set PC. See Section 7.3.2 "Debugger-to-Target Communication Error Actions". ICD3Err0033: %d bytes expected, %d bytes received. See Section 7.3.3 "Debugger-to-PC Communication Error Actions". ICD3Err0034: This version of MPLAB IDE does not support hardware revision %06x. Please upgrade to the latest version of MPLAB IDE before continuing. Find the latest MPLAB IDE at www.microchip.com. ICD3Err0035: Failed to get Device ID. See Section 7.3.1 "Read/Write Error Actions". ICD3Err0036: MPLAB IDE has lost communication with ICD 3. See Section 7.3.3 "Debugger-to-PC Communication Error Actions". ICD3Err0037: Timed out waiting for response from ICD 3. ICD3Err0038: Failed to initialize ICD 3. ICD3Err0039: ICD 3 self-test failed. For this error, the debugger is not responding: 1. Unplug and plug in the debugger. 2. Reconnect to the debugger in MPLAB IDE. 3. If the problem persists contact Microchip. ICD3Err0040: The target device is not ready for debugging. Please check your configuration bit settings and program the device before proceeding. You will receive this message when you have not programmed your device for the first time and try to Run. If you receive this message after this, or immediately after programming your device, please refer to Section 7.3.6 "Debug Failure Actions". ICD3Err0041: While receiving streaming data, ICD 3 has gotten out-of-sync with MPLAB IDE. To correct this you must reset the target device. First try to Halt, Reset and then Run again. If this does not work: 1. 2. 3. 4. Unplug and plug in the debugger. Reconnect to the debugger in MPLAB IDE. Check that the target speed is entered on the Clock tab of the Settings dialog. Run again. ICD3Err0045: You must connect to a target device to use MPLAB ICD 3. No power has been found. 1. Ensure VDD and GND are connected between the debugger and target. 2. Ensure that the target is powered. 3. Ensure that the target power is sufficient to be detected by the debugger (see Chapter 10. "Hardware Specification".) (c) 2008 Microchip Technology Inc. DS51766A-page 55 MPLAB(R) ICD 3 In-Circuit Debugger User's Guide ICD3Err0046: An error occurred while trying to read the stopwatch count. The stopwatch count may not be accurate. See Section 7.3.2 "Debugger-to-Target Communication Error Actions". ICD3Err0047: Bootloader download failed. See Section 7.3.3 "Debugger-to-PC Communication Error Actions". ICD3Err0052: The current ICD 3 hardware version %x, is out of date. This version of MPLAB IDE will support only version %x or higher. Did you click Cancel when asked to download the latest firmware? If so, you will need to download it now. Select Debugger>Settings, Configuration tab, and click Manual Download. Select the highest number .jam file and click Open. If you cannot find any files to download or if this does not work (corrupted file), you will need to get the latest version of MPLAB IDE and install it. Find the latest MPLAB IDE at www.microchip.com. ICD3Err0053: Unable to get ICD 3 protocol versions. See Section 7.3.3 "Debugger-to-PC Communication Error Actions". ICD3Err0054: MPLAB IDE's ICD 3 protocol definitions are out of date. You must upgrade MPLAB IDE to continue. Find the latest MPLAB IDE at www.microchip.com. ICD3Err0055: Unable to set firmware suite version. ICD3Err0056: Unable to get voltages from ICD 3. See Section 7.3.3 "Debugger-to-PC Communication Error Actions". ICD3Err0057: Self-test could not be completed. Ensure that you are using the ICD3 self-test board. Also, see Section 7.3.2 "Debugger-to-Target Communication Error Actions". ICD3Err0063: Test interface clock write failure. Please ensure that the tester is properly connected. ICD3Err0064: Test interface data write failure. ICD3Err0065: Test interface clock read failure. ICD3Err0066: Test interface data read failure. Clock/data not being output from the debugger. Check your connections and try again. ICD3Err0067: Failed to set/clear software breakpoint. Reprogram and try again. ICD3Err0068: Failed while writing to boot FLASH memory. ICD3Err0069: Failed while reading boot FLASH memory. ICD3Err0070: Failed while writing peripheral memory. ICD3Err0071: Failed while reading peripheral memory. See Section 7.3.1 "Read/Write Error Actions". ICD3Err0072: Unable to send freeze peripheral information. See Section 7.3.3 "Debugger-to-PC Communication Error Actions". ICD3Err0073: Device is code protected. The device on which you are attempting to operate (read, program, blank check or verify) is code protected, i.e., the code cannot be read or modified. Check your Configuration bits setting for code protection. To disable code protection, set or clear the appropriate Configuration bits in code or in the Configuration Bits window (Configure>Configuration Bits), according to the device data sheet. Then erase and reprogram the entire device. ICD3Err0082: Test interface LVP failure. ICD3Err0083: Test interface MCLR failure DS51766A-page 56 (c) 2008 Microchip Technology Inc. Error Messages 7.3 GENERAL CORRECTIVE ACTIONS These general corrective actions may solve your problem: * * * * * * * Read/Write Error Actions Debugger-to-Target Communication Error Actions Debugger-to-PC Communication Error Actions Corrupted Installation Actions USB Port Communication Error Actions Debug Failure Actions Internal Error Actions 7.3.1 Read/Write Error Actions If you receive a read or write error: 1. Did you hit Abort? This may produce read/write errors. 2. Try the action again. It may be a one-time error. 3. Ensure that the target is powered and at the correct voltage levels for the device. See the device data sheet for required device voltage levels. 4. Ensure that the debugger-to-target connection is correct (PGC and PGD are connected.) 5. For write failures, ensure that "Erase all before Program" is checked on the Program Memory tab of the Settings dialog. 6. Ensure that the cables used are of the correct length. 7.3.2 Debugger-to-Target Communication Error Actions The MPLAB ICD 3 in-circuit debugger and the target device are out-of-sync with each other. 1. Select Reset and then try the action again. 2. Ensure that the cable(s) used are the correct length. 7.3.3 Debugger-to-PC Communication Error Actions The MPLAB ICD 3 in-circuit debugger and MPLAB IDE are out-of-sync with each other. 1. 1. 2. 3. Unplug and then plug in the debugger. Reconnect to the debugger. Try the operation again. It is possible the error was a one time glitch. The version of MPLAB IDE installed may be incorrect for the version of firmware loaded on the MPLAB ICD 3 in-circuit debugger. Follow the steps outlined in Section 7.3.4 "Corrupted Installation Actions". 7.3.4 Corrupted Installation Actions The problem is most likely caused by a incomplete or corrupted installation of MPLAB IDE. 1. Uninstall all versions of MPLAB IDE from the PC. 2. Reinstall the desired MPLAB IDE version. 3. If the problem persists contact Microchip. (c) 2008 Microchip Technology Inc. DS51766A-page 57 MPLAB(R) ICD 3 In-Circuit Debugger User's Guide 7.3.5 USB Port Communication Error Actions The problem is most likely caused by a faulty or non-existent communications port. 1. Reconnect to the MPLAB ICD 3 in-circuit debugger 2. Make sure the debugger is physically connected to the PC on the appropriate USB port. 3. Make sure the appropriate USB port has been selected in the debugger Settings. 4. Make sure the USB port is not in use by another device. 5. If using a USB hub, make sure it is powered. 6. Make sure the USB drivers are loaded. 7.3.6 Debug Failure Actions The MPLAB ICD 3 in-circuit debugger was unable to perform a debugging operation. There are numerous reasons why this might occur. Top Reasons Why You Can't Debug 1. The oscillator is not working. Check your Configuration bits setting for the oscillator. 2. The target board is not powered. Check the power cable connection. 3. The MPLAB ICD 3 in-circuit debugger has somehow become physically disconnected from the PC. Check the USB communication cable connection. 4. The debugger has somehow become physically disconnected from the target board. Check the communications cable connection. 5. The device is code-protected. Check your Configuration bits setting for code protection. 6. You are trying to rebuild the project while in Release mode. Select Debug in the Build Configuration drop-down list on the project toolbar, then rebuild the project. 7. The debugger is selected as a programmer, and not as a debugger, in MPLAB IDE. 8. Debugger to PC communications has somehow been interrupted. Reconnect to the debugger in MPLAB IDE. 9. The target application has somehow become corrupted or contains errors. For example, the regular linker script was used in the project instead of the debugger version of the linker script (e.g., 18F8722.lkr was used instead of 18F8722i.lkr). Try rebuilding and reprogramming the target application. Then initiate a Power-on Reset of the target. 10. Other configuration settings are interfering with debugging. Any configuration setting that would prevent the target from executing code will also prevent the debugger from putting the code into debug mode. 11. The debugger cannot always perform the action requested. For example, the debugger cannot set a breakpoint if the target application is currently running. DS51766A-page 58 (c) 2008 Microchip Technology Inc. Error Messages Other Things to Consider 1. It is possible the error was a one time glitch. Try the operation again. 2. There may be a problem programming in general. As a test, switch to programmer mode and program the target with the simplest application possible (e.g., a program to blink an LED.) If the program will not run, then you know that something is wrong with the target setup. 3. It is possible that the target device has been damaged in some way (e.g., over current.) Development environments are notoriously hostile to components. Consider trying another target device. 4. Microchip Technology Inc. offers myriad demonstration boards to support most of its microcontrollers. Consider using one of these applications, which are known to work, to verify correct MPLAB ICD 3 in-circuit debugger functionality. Or, use the self-test board to verify the debugger itself (Section 10.7 "ICD 3 Test Interface Board".) 5. Review debugger debug operation to ensure proper application setup (Chapter 2. "Theory of Operation".) 6. If the problem persists contact Microchip. 7.3.7 Internal Error Actions Internal errors are unexpected and should not happen. They are primarily used for internal Microchip development. The most likely cause is a corrupted installation (Section 7.3.4 "Corrupted Installation Actions"). Another likely cause is exhausted system resources. 1. Try rebooting your system to free up memory. 2. Make sure you have a reasonable amount of free space on your hard drive (and that it is not overly fragmented.) If the problem persists contact Microchip. (c) 2008 Microchip Technology Inc. DS51766A-page 59 MPLAB(R) ICD 3 In-Circuit Debugger User's Guide NOTES: DS51766A-page 60 (c) 2008 Microchip Technology Inc. MPLAB(R) ICD 3 IN-CIRCUIT DEBUGGER USER'S GUIDE Part 3 - Reference Chapter 8. Basic Debug Functions............................................................................. 63 Chapter 9. Debugger Function Summary .................................................................. 65 Chapter 10. Hardware Specification ........................................................................... 79 (c) 2008 Microchip Technology Inc. DS51766A-page 61 MPLAB(R) ICD 3 In-Circuit Debugger User's Guide NOTES: DS51766A-page 62 (c) 2008 Microchip Technology Inc. MPLAB(R) ICD 3 IN-CIRCUIT DEBUGGER USER'S GUIDE Chapter 8. Basic Debug Functions 8.1 INTRODUCTION Basic MPLAB ICD 3 in-circuit debugger debug functions of breakpoints and stopwatch are discussed. 8.2 BREAKPOINTS Use breakpoints to halt code execution at specified lines in your code. Breakpoints and triggers use the same resources. Therefore, the available number of breakpoints is actually the available number of combined breakpoints/triggers. To select hardware or software breakpoints: 1. Select Debugger>Settings and click the Configuration tab. 2. Select the desired type of breakpoints for your application. A list of features for each breakpoint type, hardware or software, is shown under that type. (See Section 9.5.2 "Settings Dialog, Configuration Tab" for more information.) Note: 8.3 Using software breakpoints for debug impacts device endurance. Therefore, it is recommended that devices used in this manner not be used as production parts. STOPWATCH Use the stopwatch with breakpoints to time code execution. To set a breakpoint in code, do one of the following: * Double click or right click on a line of code to set up an individual breakpoint. * Select Debugger>Breakpoints to open the Breakpoints dialog and set up multiple breakpoints and breakpoint conditions. See Section 9.3.1 "Breakpoints Dialog" for more information. To determine the time between the breakpoints, use the stopwatch: 1. Open the Breakpoints dialog (Debugger>Breakpoints). 1. Click Stopwatch on the Breakpoints dialog to open the Stopwatch dialog. 2. Under "Start Condition", select a breakpoint from the drop-down list. Also decide if "Start condition will cause the target device to halt". 3. Under "Stop Condition", select another breakpoint from the drop-down list. Also decide if "Stop condition will cause the target device to halt". 4. Decide if there will be a "Reset stopwatch on run". 5. Click OK. (c) 2008 Microchip Technology Inc. DS51766A-page 63 MPLAB(R) ICD 3 In-Circuit Debugger User's Guide NOTES: DS51766A-page 64 (c) 2008 Microchip Technology Inc. MPLAB(R) ICD 3 IN-CIRCUIT DEBUGGER USER'S GUIDE Chapter 9. Debugger Function Summary 9.1 INTRODUCTION A summary of the MPLAB ICD 3 in-circuit debugger functions on menus, in windows and on dialogs is listed here. * * * * 9.2 Debugging Functions Debugging Dialogs/Windows Programming Functions Settings Dialog DEBUGGING FUNCTIONS When you select the MPLAB ICD 3 from the Debugger menu, the following items will be added to the MPLAB IDE functions: * Debugger Menu - additional options are added to the drop-down menu * Right Mouse Button Debugger Menu - additional options are added to this menu * Toolbars/Status Bar - a toolbar appears below the menu bar; additional information appears in the status bar 9.2.1 Debugger Menu Run F9 Execute program code until a breakpoint is encountered or until Halt is selected. Execution starts at the current Program Counter (as displayed in the status bar). The current Program Counter location is also represented as a pointer in the Program Memory window. While the program is running, several other functions are disabled. Animate Animate causes the debugger to actually execute single steps while running, updating the values of the registers as it runs. Animate runs slower than the Run function, but allows you to view changing register values in the Special Function Register window or in the Watch window. To Halt Animate, use the menu option Debugger>Halt, the toolbar Halt or . Halt F5 Halt (stop) the execution of program code. When you click Halt, status information is updated. Step Into F7 Single step through program code. For assembly code, this command executes one instruction (single or multiple cycle instructions) and then halts. After execution of one instruction, all the windows are updated. (c) 2008 Microchip Technology Inc. DS51766A-page 65 MPLAB(R) ICD 3 In-Circuit Debugger User's Guide For C code, this command executes one line of C code, which may mean the execution of one or more assembly instruction, and then halts. After execution, all the windows are updated. Note: Do not step into a SLEEP instruction. Step Over F8 Execute the instruction at the current program counter location. At a CALL instruction, Step Over executes the called subroutine and halts at the address following the CALL. If the Step Over is too long or appears to "hang", click Halt. Step Out Not available. Reset F6 Issue a Reset sequence to the target processor. This issues a MCLR to reset the program counter to the Reset vector. Breakpoints Open the Breakpoint dialog (see Section 9.3.1 "Breakpoints Dialog"). Set multiple breakpoints in this dialog. Note: You may also right click or double click on a line of code to set a simple breakpoint. Program Download your code to the target device. Read Read target memory. Information uploaded to MPLAB IDE. Erase Flash Device Erase all Flash memory. Debug Read Reads program memory using the debug executive. Abort Operation Abort any programming operation (e.g., program, read, etc.). Terminating an operation will leave the device in an unknown state. Reconnect Attempt to re-establish communications between the PC and the MPLAB ICD 3 in-circuit debugger. The progress of this connection is shown on the ICD 3 tab of the Output dialog. Settings Open the Programmer dialog (see Section 9.5 "Settings Dialog"). Set up program and firmware options. DS51766A-page 66 (c) 2008 Microchip Technology Inc. Debugger Function Summary 9.2.2 Right Mouse Button Debugger Menu These debugger menu options will appear on the right mouse menus in code displays, such as program memory and source code files. Descriptions of other menu options not listed here can be found in the MPLAB IDE Help or the MPLAB Editor Help. Set Breakpoint Set or remove a breakpoint at the currently selected line. Breakpoints Remove, enable or disable all breakpoints. Run To Cursor Run the program to the current cursor location. Formerly Run to Here. Set PC at Cursor Set the Program Counter (PC) to the cursor location. Center Debug Location Center the current PC line in the window. 9.2.3 Toolbars/Status Bar When the MPLAB ICD 3 in-circuit debugger is selected as a debugger, these toolbars are displayed in MPLAB IDE: * Basic debug toolbar (Run, Halt, Animate, Step Into, Step Over, Step Out, Reset). * Simple program toolbar (Read, Program, Erase Flash Device). The selected debug tool (MPLAB ICD 3), as well as other development information, is displayed in the status bar on the bottom of the MPLAB IDE desktop. Refer to the MPLAB IDE on-line help for information on the contents of the status bar. (c) 2008 Microchip Technology Inc. DS51766A-page 67 MPLAB(R) ICD 3 In-Circuit Debugger User's Guide 9.3 DEBUGGING DIALOGS/WINDOWS Open the following debug dialogs and windows using the menu items mentioned in Section 9.2 "Debugging Functions". * Breakpoints Dialog - Set Breakpoint Dialog - Stopwatch Dialog - Event Breakpoints Dialog - Sequenced Breakpoints Dialog - ANDed Breakpoints Dialog 9.3.1 Breakpoints Dialog To set up breakpoints, select Debugger>Breakpoints. Set up different types of breakpoints in this dialog. Click on Add Breakpoint to add breakpoints to the dialog window. Depending on your selected device, there may be other buttons for more advanced breakpoint options. 9.3.1.1 BREAKPOINT DIALOG WINDOW Information about each breakpoint is visible in this window. TABLE 9-1: BREAKPOINT DIALOG WINDOW Control Breakpoint Type Function Type of breakpoint - program or data Address Hex address of breakpoint location File Line # File name and line number of breakpoint location Enabled Check to enable a breakpoint Once a breakpoint has been added to the window, you may right click on it to open a menu of options: * * * * DS51766A-page 68 Delete - delete selected breakpoint Edit/View - open the Set Breakpoint Dialog Delete All - delete all listed breakpoints Disable All - disable all listed breakpoints (c) 2008 Microchip Technology Inc. Debugger Function Summary 9.3.1.2 BREAKPOINT DIALOG BUTTONS Use the buttons to add a breakpoint and set up additional break conditions. Also, a stopwatch is available for use with breakpoints and triggers. Note: Buttons displayed will depend on the selected device. TABLE 9-2: BREAKPOINT DIALOG BUTTONS Control Function Related Dialog Add Breakpoint Add a breakpoint Section 9.3.2 "Set Breakpoint Dialog" Stopwatch Set up the stopwatch Section 9.3.3 "Stopwatch Dialog" Event Breakpoints Set up break on an event Section 9.3.4 "Event Breakpoints Dialog" Sequenced Breakpoints Set up a sequence until break Section 9.3.5 "Sequenced Breakpoints Dialog" ANDed Breakpoints Set up ANDed condition until break 9.3.2 Section 9.3.6 "ANDed Breakpoints Dialog" Set Breakpoint Dialog Click Add Breakpoint in the Breakpoints Dialog to display this dialog. Select a breakpoint for the Breakpoints dialog here. 9.3.2.1 PROGRAM MEMORY TAB Set up a program memory breakpoint here. TABLE 9-3: Control PROGRAM MEMORY BREAKPOINT Function Address Location of breakpoint in hex Breakpoint Type The type of program memory breakpoint. See the device data sheet for more information on table reads/writes. Program Memory Execution - break on execution of above address TBLRD Program Memory - break on table read of above address TBLWT Program Memory - break on table write to above address Pass Count Break on pass count condition. Always break - always break as specified in "Breakpoint type" Break occurs Count instructions after Event - wait Count (0-255) instructions before breaking after event specified in "Breakpoint type" Event must occur Count times - break only after event specified in "Breakpoint type" occurs Count (0-255) times (c) 2008 Microchip Technology Inc. DS51766A-page 69 MPLAB(R) ICD 3 In-Circuit Debugger User's Guide 9.3.2.2 DATA MEMORY TAB Set up a data memory breakpoint here. TABLE 9-4: DATA MEMORY BREAKPOINT Control Function Address Location of breakpoint in hex Breakpoint Type The type of data memory breakpoint. See the device data sheet for more information on X Bus reads/writes. X Bus Read - break on an X bus read of above address X Bus Read Specific Byte - break on an X bus read of above address for the specific byte value in "Specific Value" X Bus Read Specific Word - break on an X bus read of above address for the specific word value in "Specific Value" X Bus Write - break on an X bus write of above address X Bus Write Specific Byte - break on an X bus write of above address for the specific byte value in "Specific Value" X Bus Write Specific Word - break on an X bus write of above address for the specific word value in "Specific Value" Pass Count Break on pass count condition. Always break - always break as specified in "Breakpoint type" Break occurs Count instructions after Event - wait Count (0-255) instructions before breaking after event specified in "Breakpoint type" Event must occur Count times - break only after event specified in "Breakpoint type" occurs Count (0-255) times 9.3.3 Stopwatch Dialog Click Stopwatch in the Breakpoints Dialog to display this dialog. The stopwatch allows timing from one breakpoint/trigger condition to the next. The stopwatch value is in decimal. TABLE 9-5: STOPWATCH SETUP Control DS51766A-page 70 Function Start Condition Select an available breakpoint or trigger condition to start the stopwatch. Available breakpoints/triggers are those previously added to the breakpoint dialog. Select None to clear the start condition. To halt the program run on this condition, check the check box next to "Start condition will cause the target device to halt". Stop Condition Select an available breakpoint or trigger condition to stop the stopwatch. Available breakpoints/triggers are those previously added to the breakpoint dialog. Select None to clear the stop condition. To halt the program run on this condition, check the check box next to "Stop condition will cause the target device to halt". Reset stopwatch on run Reset the stopwatch values to zero every time the program is run. (c) 2008 Microchip Technology Inc. Debugger Function Summary 9.3.4 Event Breakpoints Dialog Click Event Breakpoints in the Breakpoints Dialog to display this dialog. Select a condition where the program will always break: * Break on Watchdog Timer - Break every time the watchdog timer times out. Make sure the Watchdog Timer is enabled in the Configuration bits. * Break on SLEEP instruction - Break when a SLEEP instruction is encountered in the program. 9.3.5 Sequenced Breakpoints Dialog Click Sequenced Breakpoints in the Breakpoints Dialog to display this dialog. Set up a sequential occurrence of breakpoints. Sequence execution of breakpoints is bottom-up; the last breakpoint in the sequence occurs first. To add a breakpoint to a sequence: * Select a breakpoint from the list of "Available Breakpoints". Available breakpoints/triggers are those previously added to the breakpoint dialog. * Select a sequence for the list of "Sequences". * Click Add. To change the order of breakpoints in a sequence, drag-and-drop the breakpoint in the "Sequences list". To remove a breakpoint from a sequence: * Select the breakpoint in the "Sequences" list. * Click Remove. 9.3.6 ANDed Breakpoints Dialog Click ANDed Breakpoints in the Breakpoints Dialog to display this dialog. Set up an ANDed condition for breaking, i.e., breakpoint 1 AND breakpoint 2 must occur at the same time before a program halt. This can only be accomplished if a data breakpoint and a program memory breakpoint occur at the same time. To add a breakpoint to the AND condition: * Select a breakpoint from the list of "Available Breakpoints". Available breakpoints/triggers are those previously added to the breakpoint dialog. * Click Add. To remove a breakpoint from a sequence: * Select the breakpoint in the "ANDed Breakpoints" list. * Click Remove. Close Close this window. Find Opens the Find dialog. In the Find What field, enter a string of text you want to find, or select text from the drop-down list. You can also select text in the edit window or place the cursor over a word you want to search for, before you open the Find dialog. In the Find dialog you may select any of the available options and the direction you want to search. Up searches backward from the insertion point, Down searches forward. (c) 2008 Microchip Technology Inc. DS51766A-page 71 MPLAB(R) ICD 3 In-Circuit Debugger User's Guide Find Next Find the next instance of Find text. repeats the last Find. + reverses the direction of the last Find. Go To Jump to the specified item: * Trigger - Jump to the location of the trigger. * Top - Jump to the top of the window. * Bottom - Jump to the bottom of the window. Show Source Show/hide the source code listing on the bottom of the window. Refresh Refresh the viewable contents of the window. Properties Set up window properties. DS51766A-page 72 (c) 2008 Microchip Technology Inc. Debugger Function Summary 9.4 PROGRAMMING FUNCTIONS When you select the MPLAB ICD 3 in-circuit debugger from the Programmer menu, program items will be added to the following MPLAB IDE functions: * Programmer Menu * Toolbars/Status Bar 9.4.1 Programmer Menu Program Program specified memory areas: program memory, Configuration bits, ID locations and/or EEPROM data. See the Settings dialog for programming options. Verify Verify programming of specified memory areas: program memory, Configuration bits, ID locations and/or EEPROM data. Read Read specified memory areas: program memory, Configuration bits, ID locations and/or EEPROM data. See the Settings dialog for read options. Blank Check All Check to see that all device memory is erased/blank. Erase Flash Device Erase all Flash memory. Settings Open the Programmer dialog (see Section 9.5 "Settings Dialog"). Set up program and firmware options. 9.4.2 Toolbars/Status Bar When the MPLAB ICD 3 in-circuit debugger is selected as a programmer, these toolbars are displayed in MPLAB IDE: * Basic program toolbar (Blank Check All, Read, Program, Verify, Erase Flash Device). The selected programmer (MPLAB ICD 3), as well as other programming information, is displayed in the status bar on the bottom of the MPLAB IDE desktop. Refer to the MPLAB IDE on-line help for information on the contents of the status bar. (c) 2008 Microchip Technology Inc. DS51766A-page 73 MPLAB(R) ICD 3 In-Circuit Debugger User's Guide 9.5 SETTINGS DIALOG Select either Debugger>Settings or Programmer>Settings to open the Settings dialog and set up the MPLAB ICD 3 in-circuit debugger. Note: * * * * * * * * Tabs displayed will depend on the selected device. Settings Dialog, Program Memory Tab Settings Dialog, Configuration Tab Settings Dialog, Freeze on Halt Tab Settings Dialog, Status Tab Settings Dialog, Clock Tab Settings Dialog, Secure Segment Tab Settings Dialog, Warnings Tab Settings Dialog, Power Tab 9.5.1 Settings Dialog, Program Memory Tab This tab allows you to set up debug/programming options. * Allow MPLAB ICD 3 to select memories and ranges - the debugger uses your selected device and default settings to determine what to program. * Manually select memories and ranges - you select the type and range of memory to program. TABLE 9-6: MANUAL SELECTION OPTIONS Memories Program Check to program Program Memory into target. Configuration Check to program Configuration bits into target. Note: This memory is always programmed when debugger selected as a debugger. EEPROM Check to erase and then program EEPROM memory on target, if available. Uncheck to erase EEPROM memory on target. ID Check to program ID Memory into target. Program Options Erase all before Program Check to erase all memory before programming begins. Unless programming new or already erased devices, it is important to have this box checked. If not checked, the device is not erased and program code will be merged with the code already in the device. Program Memory Start, End The starting and ending hex address range in program memory for programming, reading, or verification. If you receive a programming error due to an incorrect end address, you need to perform a reconnect, correct the end address and program again. Note: The address range does not apply to the Erase function. The Erase function will erase all data on the device. * Set up automatic options - choose to "Program after successful build" and/or "Run after successful program". DS51766A-page 74 (c) 2008 Microchip Technology Inc. Debugger Function Summary 9.5.2 Settings Dialog, Configuration Tab Configure debugger operation on this tab. TABLE 9-7: CONFIGURATION ITEMS Download Firmware Set up firmware download options. Auto Download Latest Firmware Check to allow automatic download of the latest version of firmware for the target device (recommended). Manual Download Manually select a firmware file to download to the target device. Breakpoints Depending on your selected device, you may be able to use software breakpoints. Review the text beneath each type of breakpoint to determine which is best for your current needs. Use Hardware Breakpoints This is the default/classic mode for breakpoint behavior. Using hardware breakpoints means: * Number of breakpoints: limited * Breakpoints are written to debug registers * Time to set breakpoints: minimal * Skidding: yes Use Software Breakpoints Using software breakpoints means: * Number of breakpoints: unlimited * Breakpoints are written to program memory * Time to set breakpoints: oscillator speed dependent - can take minutes * Skidding: no Note: Using software breakpoints for debug impacts device endurance. Therefore, it is recommended that devices used in this manner not be used as production parts. (c) 2008 Microchip Technology Inc. DS51766A-page 75 MPLAB(R) ICD 3 In-Circuit Debugger User's Guide 9.5.3 Settings Dialog, Freeze on Halt Tab Select peripherals to freeze on halt on this tab. PIC18 MCU Devices To freeze/unfreeze all device peripherals on halt, check/uncheck the "Freeze on Halt" checkbox. If this does not halt your desired peripheral, be aware that some peripherals have no freeze on halt capability and cannot be controlled by the debugger. dsPIC30F/33F, PIC24F/H and PIC32MX Devices For peripherals in the list "Peripherals to Freeze on Halt", check to freeze that peripheral on a halt. Uncheck the peripheral to let it run while the program is halted. If you do not see a peripheral on the list, check "All Other Peripherals". If this does not halt your desired peripheral, be aware that some peripherals have no freeze on halt capability and cannot be controlled by the debugger. To select all peripherals, including "All Other Peripherals", click Check All. To deselect all peripherals, including "All Other Peripherals", click Uncheck All. 9.5.4 Settings Dialog, Status Tab View the status of your MPLAB ICD 3 system on this tab. TABLE 9-8: STATUS ITEMS Versions Firmware Suite Version Debugger firmware suite version. The firmware suite consists of the three items specified below. FPGA Version Internal FPGA chip firmware version. Algorithm Plug-in Version Debugger algorithm plug-in version. For your selected device, an algorithm is used to support the device plugged into the target. OS Version Debugger operating system version. Voltages DS51766A-page 76 ICD 3 VPP Debugger VPP. ICD 3 VDD Debugger VDD. Target VDD VDD sensed at target. Refresh Voltages Sensing of Status tab items occurs when the tab is achieved. To see updates otherwise, click this button. (c) 2008 Microchip Technology Inc. Debugger Function Summary 9.5.5 Settings Dialog, Clock Tab Enter the run-time clock (instruction) speed on this tab. This does not set the speed, but informs the debugger of its value. TABLE 9-9: CLOCK OPTIONS Target Run-Time Instruction Speed Speed value Enter a value for the "Speed unit" selected. Example 1: For a PIC24 MCU and a target clock oscillator at 32 MHz (HS), instruction speed = 32 MHz/2 = 16 MIPS. Example 2: For a PIC18F8722 MCU and a target clock oscillator at 10 MHz (HS) making use of the PLL (x4 = 40 MHz), instruction speed = 40 MHz/4 = 10 MIPS. Speed unit Select either: KIPS - Thousands (103) of instructions per second MIPS - Millions (106) of instructions per second Debug Mode Clock Use FRC in Debug mode Select the checkbox if you want to use the fast internal oscillator on the device. If selected any non-frozen peripherals will operate at the FRC during debugging (see Section 9.5.3 "Settings Dialog, Freeze on Halt Tab"). 9.5.6 Settings Dialog, Secure Segment Tab For CodeGuardTM Security devices, set up secure segment properties on this tab. For more details on CodeGuard Security functionality, please refer to the CodeGuard Security reference manual for 16-bit devices (DS70180) and dsPIC33F/PIC24H and dsPIC30F device programming specifications found on our website. TABLE 9-10: SECURE SEGMENT OPTIONS Full Chip Programming Click to select to program all program memory segments. Segment Programming Click to select segment programming. Select from: - Boot, secure and general segments - Secure and general segments - General segment only 9.5.7 Settings Dialog, Warnings Tab A list of all MPLAB ICD 3 in-circuit debugger warnings are displayed on this tab. * Check a warning to enable it. The warning will be displayed in the Output window. * Uncheck a warning to disable it. Warnings are not errors and will not stop your project from building. If you receive error messages, please see Chapter 7. "Error Messages". 9.5.8 Settings Dialog, Power Tab Set up the power options on this tab. Click in the checkbox to enable/disable "Power target circuit from MPLAB ICD 3". Adjust the slide bar to select the voltage. The value in the field changes according to your adjustments. (c) 2008 Microchip Technology Inc. DS51766A-page 77 MPLAB(R) ICD 3 In-Circuit Debugger User's Guide NOTES: DS51766A-page 78 (c) 2008 Microchip Technology Inc. MPLAB(R) ICD 3 IN-CIRCUIT DEBUGGER USER'S GUIDE Chapter 10. Hardware Specification 10.1 INTRODUCTION The hardware and electrical specifications of the MPLAB ICD 3 in-circuit debugger system are detailed. 10.2 HIGHLIGHTS This chapter discusses: * * * * * * 10.3 Declaration of Conformity USB Port/Power MPLAB ICD 3 Debugger Standard Communication Hardware ICD 3 Test Interface Board Target Board Considerations DECLARATION OF CONFORMITY We Microchip Technology, Inc. 2355 W. Chandler Blvd. Chandler, Arizona 85224-6199 USA hereby declare that the product: MPLAB(R) ICD 3 In-Circuit Debugger complies with the following standards, provided that the restrictions stated in the operating manual are observed: Standards: EN61010-1 Laboratory Equipment Microchip Technology, Inc. Date: August 2006 Important Information Concerning the Use of the MPLAB ICD 3 In-Circuit Debugger Due to the special nature of the MPLAB ICD 3 in-circuit debugger, the user is advised that it can generate higher than normal levels of electromagnetic radiation which can interfere with the operation of all kinds of radio and other equipment. To comply with the European Approval Regulations therefore, the following restrictions must be observed: 1. The development system must be used only in an industrial (or comparable) area. 2. The system must not be operated within 20 meters of any equipment which may be affected by such emissions (radio receivers, TVs etc.). (c) 2008 Microchip Technology Inc. DS51766A-page 79 MPLAB(R) ICD 3 In-Circuit Debugger User's Guide 10.4 USB PORT/POWER The MPLAB ICD 3 in-circuit debugger is connected to the host PC via a Universal Serial Bus (USB) port, version 2.0 compliant. The USB connector is located on the side of the pod. The system is capable of reloading the firmware via the USB interface. System power is derived from the USB interface. The debugger is classified as a high power system per the USB specification, and requires 300 mA of power from the USB to function in all operational modes (debugger/programmer). Note: The MPLAB ICD 3 in-circuit debugger is powered through its USB connection. The target board is powered from its own supply. Alternatively, the MPLAB ICD 3 can power it only if the target consumes less than 100 mA. Cable Length - The PC-to-debugger cable length for proper operation is shipped in the debugger kit. Powered Hubs - If you are going to use a USB hub, make sure it is self-powered. Also, USB ports on PC keyboards do not have enough power for the debugger to operate. PC Hibernate/Power-Down Modes - Disable the hibernate or other power saver modes on your PC to ensure proper USB communications with the debugger. 10.5 MPLAB ICD 3 DEBUGGER The debugger consists of a main board enclosed in the casing with a USB connector and an RJ-11 connector. On the debugger enclosure are indicator lights (LEDs). 10.5.1 Main Board This component has the interface processor (dsPIC DSC), the USB 2.0 interface capable of USB speeds of 480 Mb/sec, a Field Programmable Gate Array (FPGA) for general system control and increased communication throughput, an SRAM for holding the program code image for programming into the emulation device on-board Flash and LED indicators. 10.5.2 Indicator Lights (LEDs) The indicator lights have the following significance. LED DS51766A-page 80 Color Description Active Blue Lit when power is first applied or when target is connected. Status Green Lit when the debugger is operating normally - standby. Red Lit when an operation has failed. Orange Lit when the debugger is busy. (c) 2008 Microchip Technology Inc. Hardware Specification 10.6 STANDARD COMMUNICATION HARDWARE For standard debugger communication with a target (Section 2.4 "Debugger To Target Communication", "Standard ICSP Device Communication"), use the RJ-11 connector. To use this type of communication with a header board, you may need a device-specific Processor Pak, which includes an 8-pin connector header board containing the desired ICE/ICD device and a standard adapter board. Note: Older header boards used a 6-pin (RJ-11) connector instead of an 8-pin connector, so these headers may be connected directly to the debugger. For more on available header boards, see the "Header Board Specification" (DS51292). 10.6.1 Standard Communication The standard communication is the main interface to the target processor. It contains the connections to the high voltage (VPP), VDD sense lines, and clock and data connections required for programming and connecting with the target devices. The VPP high-voltage lines can produce a variable voltage that can swing from 0 to 14 volts to satisfy the voltage requirements for the specific emulation processor. The VDD sense connection draws very little current from the target processor. The actual power comes from the MPLAB ICD 3 in-circuit debugger system as the VDD sense line is used as a reference only to track the target voltage. The VDD connection is isolated with an optical switch. The clock and data connections are interfaces with the following characteristics: * Clock and data signals are in high-impedance mode (even when no power is applied to the MPLAB ICD 3 in-circuit debugger system) * Clock and data signals are protected from high voltages caused by faulty targets systems, or improper connections * Clock and data signals are protected from high current caused from electrical shorts in faulty target systems FIGURE 10-1: 6-PIN STANDARD PINOUT Pin Standard Socket 2 4 6 Bottom of Target Board 1 (c) 2008 Microchip Technology Inc. 3 5 1 2 3 4 5 6 Name VPP VDD_TGT GND PGD (ICSPDAT) PGC (ICSPCLK) LVP Function Power Power on target Ground Standard Com Data Standard Com Clock Low Voltage Programming DS51766A-page 81 MPLAB(R) ICD 3 In-Circuit Debugger User's Guide 10.6.2 Modular Cable and Connector For standard communications, a modular cable connects the debugger and the target application. The specifications for this cable and its connectors are listed below. 10.6.2.1 MODULAR CONNECTOR SPECIFICATION * Manufacturer, Part Number - AMP Incorporated, 555165-1 * Distributor, Part Number - Digi-Key, A9031ND The following table shows how the modular connector pins on an application correspond to the microcontroller pins. This configuration provides full ICD functionality. FIGURE 10-2: MODULAR CONNECTOR PINOUT OF TARGET BOARD 1 6 Modular Connector Pin Microcontroller Pin 6 LVP 5 RB6 4 RB7 3 Ground 2 VDD Target 1 VPP Front view of Modular Connector on Target Board 6 1 Bottom view of Modular Connector Pinout on Target Board 10.6.2.2 MODULAR PLUG SPECIFICATION * Manufacturer, Part Number - AMP Incorporated, 5-554710-3 * Distributor, Part Number - Digi-Key, A9117ND 10.6.2.3 MODULAR CABLE SPECIFICATION * Manufacturer, Part Number - Microchip Technology, 07-00024 8.00" Pin 1 10.7 Pin 6 ICD 3 TEST INTERFACE BOARD This board can be used to verify that the debugger is functioning properly. To use this board: DS51766A-page 82 (c) 2008 Microchip Technology Inc. Hardware Specification 1. Disconnect the debugger from the target and the PC. 2. Connect the ICD 3 test interface board to the debugger using the modular cable. MPLAB(R) ICD 3 ICD 3 Test Interface Board Modular Cable USB/Power From PC 3. Connect the debugger to the PC. 4. Select the MPLAB ICD 3 in-circuit debugger as either a debugger or programmer in MPLAB IDE. 5. MPLAB IDE will invoke and run the complete self-test and give you a status (pass/fail). 10.8 TARGET BOARD CONSIDERATIONS The target board should be powered according to the requirements of the selected device (2.0V-5.5V) and the application. The debugger does sense target power. There is a 10K load on VDD_TGT. Depending on the type of debugger-to-target communications used, there will be some considerations for target board circuitry: * Section 2.5.2 "Target Connection Circuitry" * Section 2.5.5 "Circuits That Will Prevent the Debugger From Functioning" (c) 2008 Microchip Technology Inc. DS51766A-page 83 MPLAB(R) ICD 3 In-Circuit Debugger User's Guide NOTES: DS51766A-page 84 (c) 2008 Microchip Technology Inc. MPLAB(R) ICD 3 IN-CIRCUIT DEBUGGER USER'S GUIDE Glossary Absolute Section A section with a fixed (absolute) address that cannot be changed by the linker. Access Memory (PIC18 Only) Special registers on PIC18 devices that allow access regardless of the setting of the Bank Select Register (BSR). Address Value that identifies a location in memory. Alphabetic Character Alphabetic characters are those characters that are letters of the arabic alphabet (a, b, ..., z, A, B, ..., Z). Alphanumeric Alphanumeric characters are comprised of alphabetic characters and decimal digits (0,1, ..., 9). ANSI American National Standards Institute is an organization responsible for formulating and approving standards in the United States. Application A set of software and hardware that may be controlled by a PIC microcontroller. Archive A collection of relocatable object modules. It is created by assembling multiple source files to object files, and then using the archiver to combine the object files into one library file. A library can be linked with object modules and other libraries to create executable code. Archiver A tool that creates and manipulates libraries. ASCII American Standard Code for Information Interchange is a character set encoding that uses 7 binary digits to represent each character. It includes upper and lower case letters, digits, symbols and control characters. Assembler A language tool that translates assembly language source code into machine code. Assembly Language A programming language that describes binary machine code in a symbolic form. Asynchronous Stimulus Data generated to simulate external inputs to a simulator device. (c) 2008 Microchip Technology Inc. DS51766A-page 85 MPLAB(R) ICD 3 In-Circuit Debugger User's Guide Bookmarks Use bookmarks to easily locate specific lines in a file. Under the Edit menu, select Bookmarks to manage bookmarks. Toggle (enable / disable) a bookmark, move to the next or previous bookmark, or clear all bookmarks. Breakpoint, Hardware An event whose execution will cause a halt. Breakpoint, Software An address where execution of the firmware will halt. Usually achieved by a special break instruction. Build Compile and link all the source files for an application. C A general-purpose programming language which features economy of expression, modern control flow and data structures, and a rich set of operators. Calibration Memory A special function register or registers used to hold values for calibration of a PIC microcontroller on-board RC oscillator or other device peripherals. Clean Under the MPLAB IDE Project menu, Clean removes all intermediary project files, such as object, hex and debug files, for the active project. These files are recreated from other files when a project is built. COFF Common Object File Format. An object file of this format contains machine code, debugging and other information. Command Line Interface A means of communication between a program and its user based solely on textual input and output. Compiler A program that translates a source file written in a high-level language into machine code. Configuration Bits Special-purpose bits programmed to set PIC microcontroller modes of operation. A Configuration bit may or may not be preprogrammed. Control Directives Directives in assembly language code that cause code to be included or omitted based on the assembly-time value of a specified expression. Cross Reference File A file that references a table of symbols and a list of files that references the symbol. If the symbol is defined, the first file listed is the location of the definition. The remaining files contain references to the symbol. Data Directives Data directives are those that control the assembler's allocation of program or data memory and provide a way to refer to data items symbolically; that is, by meaningful names. DS51766A-page 86 (c) 2008 Microchip Technology Inc. Glossary Data Memory On Microchip MCU and DSC devices, data memory (RAM) is comprised of General Purpose Registers (GPRs) and Special Function Registers (SFRs). Some devices also have EEPROM data memory. Debugging Information Compiler and assembler options that, when selected, provide varying degrees of information used to debug application code. See compiler or assembler documentation for details on selecting debug options. Device Programmer A tool used to program electrically programmable semiconductor devices such as microcontrollers. Digital Signal Controller A microcontroller device with digital signal processing capability, i.e., Microchip dsPIC DSC devices. Directives Statements in source code that provide control of the language tool's operation. Download Download is the process of sending data from a host to another device, such as an debugger, programmer or target board. DSC See Digital Signal Controller. EEPROM Electrically Erasable Programmable Read Only Memory. A special type of PROM that can be erased electrically. Data is written or erased one byte at a time. EEPROM retains its contents even when power is turned off. Emulation The process of executing software loaded into emulation memory as if it were firmware residing on a microcontroller device. Emulation Memory Program memory contained within the debugger. Debugger Hardware that performs emulation. Debugger System The MPLAB ICE 2000 and MPLAB ICE 4000 debugger systems include the pod, processor module, device adapter, target board, cables, and MPLAB IDE software. The MPLAB ICD 3 system consists of a pod, a driver (and potentially a receiver) card, target board, cables, and MPLAB IDE software. Environment - IDE The particular layout of the desktop for application development. Environment - MPLAB PM3 A folder containing files on how to program a device. This folder can be transferred to a SD/MMC card. EPROM Erasable Programmable Read Only Memory. A programmable read-only memory that can be erased usually by exposure to ultraviolet radiation. (c) 2008 Microchip Technology Inc. DS51766A-page 87 MPLAB(R) ICD 3 In-Circuit Debugger User's Guide Event A description of a bus cycle which may include address, data, pass count, external input, cycle type (fetch, R/W), and time stamp. Events are used to describe triggers, breakpoints and interrupts. Export Send data out of the MPLAB IDE in a standardized format. Extended Microcontroller Mode In extended microcontroller mode, on-chip program memory as well as external memory is available. Execution automatically switches to external if the program memory address is greater than the internal memory space of the PIC17 or PIC18 device. External Label A label that has external linkage. External Linkage A function or variable has external linkage if it can be referenced from outside the module in which it is defined. External Symbol A symbol for an identifier which has external linkage. This may be a reference or a definition. External Symbol Resolution A process performed by the linker in which external symbol definitions from all input modules are collected in an attempt to resolve all external symbol references. Any external symbol references which do not have a corresponding definition cause a linker error to be reported. External Input Line An external input signal logic probe line (TRIGIN) for setting an event based upon external signals. External RAM Off-chip Read/Write memory. File Registers On-chip data memory, including General Purpose Registers (GPRs) and Special Function Registers (SFRs). Filter Determine by selection what data is included/excluded in a trace display or data file. Flash A type of EEPROM where data is written or erased in blocks instead of bytes. FNOP Forced No Operation. A forced NOP cycle is the second cycle of a two-cycle instruction. Since the PIC microcontroller architecture is pipelined, it prefetches the next instruction in the physical address space while it is executing the current instruction. However, if the current instruction changes the program counter, this prefetched instruction is explicitly ignored, causing a forced NOP cycle. GPR General Purpose Register. The portion of device data memory (RAM) available for general use. Halt A stop of program execution. Executing Halt is the same as stopping at a breakpoint. DS51766A-page 88 (c) 2008 Microchip Technology Inc. Glossary Hex Code Executable instructions stored in a hexadecimal format code. Hex code is contained in a hex file. Hex File An ASCII file containing hexadecimal addresses and values (hex code) suitable for programming a device. High Level Language A language for writing programs that is further removed from the processor than assembly. ICD In-Circuit Debugger. MPLAB ICD 2 is Microchip's in-circuit debugger. ICE In-Circuit Debugger. MPLAB ICE 2000, MPLAB ICE 4000 and MPLAB ICD 3 system are Microchip's in-circuit debuggers. ICSP In-Circuit Serial Programming. A method of programming Microchip embedded devices using serial communication and a minimum number of device pins. IDE Integrated Development Environment. MPLAB IDE is Microchip's integrated development environment. Import Bring data into the MPLAB IDE from an outside source, such as from a hex file. Instruction Set The collection of machine language instructions that a particular processor understands. Instructions A sequence of bits that tells a central processing unit to perform a particular operation and can contain data to be used in the operation. Internal Linkage A function or variable has internal linkage if it can not be accessed from outside the module in which it is defined. International Organization for Standardization An organization that sets standards in many businesses and technologies, including computing and communications. Interrupt A signal to the CPU that suspends the execution of a running application and transfers control to an Interrupt Service Routine (ISR) so that the event may be processed. Upon completion of the ISR, normal execution of the application resumes. Interrupt Handler A routine that processes special code when an interrupt occurs. Interrupt Request An event which causes the processor to temporarily suspend normal instruction execution and to start executing an interrupt handler routine. Some processors have several interrupt request events allowing different priority interrupts. (c) 2008 Microchip Technology Inc. DS51766A-page 89 MPLAB(R) ICD 3 In-Circuit Debugger User's Guide Interrupt Service Routine User-generated code that is entered when an interrupt occurs. The location of the code in program memory will usually depend on the type of interrupt that has occurred. IRQ See Interrupt Request. ISO See International Organization for Standardization. ISR See Interrupt Service Routine. Librarian See Archiver. Library See Archive. Linker A language tool that combines object files and libraries to create executable code, resolving references from one module to another. Linker Script Files Linker script files are the command files of a linker. They define linker options and describe available memory on the target platform. Listing Directives Listing directives are those directives that control the assembler listing file format. They allow the specification of titles, pagination and other listing control. Listing File A listing file is an ASCII text file that shows the machine code generated for each C source statement, assembly instruction, assembler directive, or macro encountered in a source file. Local Label A local label is one that is defined inside a macro with the LOCAL directive. These labels are particular to a given instance of a macro's instantiation. In other words, the symbols and labels that are declared as local are no longer accessible after the ENDM macro is encountered. Logic Probes Up to 14 logic probes can be connected to some Microchip debuggers. The logic probes provide external trace inputs, trigger output signal, +5V, and a common ground. Machine Code The representation of a computer program that is actually read and interpreted by the processor. A program in binary machine code consists of a sequence of machine instructions (possibly interspersed with data). The collection of all possible instructions for a particular processor is known as its "instruction set". Machine Language A set of instructions for a specific central processing unit, designed to be usable by a processor without being translated. Macro Macro instruction. An instruction that represents a sequence of instructions in abbreviated form. DS51766A-page 90 (c) 2008 Microchip Technology Inc. Glossary Macro Directives Directives that control the execution and data allocation within macro body definitions. Makefile Export to a file the instructions to Make the project. Use this file to Make your project outside of MPLAB IDE, i.e., with a make. Under Project>Build Options>Project, Directories tab, you must have selected "Assemble/Compile/Link in the project directory" under "Build Directory Policy" for this feature to work. Make Project A command that rebuilds an application, recompiling only those source files that have changed since the last complete compilation. MCU Microcontroller Unit. An abbreviation for microcontroller. Also C. Message Text displayed to alert you to potential problems in language tool operation. A message will not stop operation. Microcontroller A highly integrated chip that contains a CPU, RAM, program memory, I/O ports and timers. Microcontroller Mode One of the possible program memory configurations of PIC17 and PIC18 microcontrollers. In microcontroller mode, only internal execution is allowed. Thus, only the on-chip program memory is available in microcontroller mode. Microprocessor Mode One of the possible program memory configurations of PIC17 and PIC18 microcontrollers. In microprocessor mode, the on-chip program memory is not used. The entire program memory is mapped externally. Mnemonics Text instructions that can be translated directly into machine code. Also referred to as opcodes. MPASMTM Assembler Microchip Technology's relocatable macro assembler for PIC microcontroller devices, KeeLoq(R) devices and Microchip memory devices. MPLAB ASM30 Microchip's relocatable macro assembler for dsPIC digital signal controller and PIC24 PIC devices. MPLAB C17 Obsoleted along with PIC17 MCU devices. See the MPLAB C18 C compiler. Refers to the MPLAB C17 C compiler from Microchip. MPLAB C17 is the C compiler for PIC17 MCU devices. MPLAB C18 Refers to the MPLAB C18 C compiler from Microchip. MPLAB C18 is the C compiler for PIC18 MCU devices. MPLAB C30 Microchip's C compiler for dsPIC digital signal controller and PIC24 PIC devices. (c) 2008 Microchip Technology Inc. DS51766A-page 91 MPLAB(R) ICD 3 In-Circuit Debugger User's Guide MPLAB ICD 2 Microchip's in-circuit debugger that works with MPLAB IDE. The ICD supports Flash devices with built-in debug circuitry. The main component of each ICD is the pod. A complete system consists of a pod, header board (with a device-ICD), target board, cables, and MPLAB IDE software. MPLAB ICE 2000 Microchip's in-circuit debugger that works with MPLAB IDE. MPLAB ICE 2000 supports 8-bit PIC MCUs. The main component of each ICE is the pod. A complete system consists of a pod, processor module, cables, and MPLAB IDE software. MPLAB ICE 4000 Not recommended for new designs. See the MPLAB ICD 3 in-circuit debugger. Microchip's in-circuit debugger that works with MPLAB IDE. MPLAB ICE 4000 supports PIC18F and PIC24 MCUs and dsPIC DSCs. The main component of each ICE is the pod. A complete system consists of a pod, processor module, cables, and MPLAB IDE software. MPLAB IDE Microchip's Integrated Development Environment. MPLAB LIB30 MPLAB LIB30 archiver/librarian is an object librarian for use with object modules created using either MPLAB ASM30 or MPLAB C30 C compiler. MPLAB LINK30 MPLAB LINK30 is an object linker for the Microchip MPLAB ASM30 assembler and the Microchip MPLAB C30 C compiler. MPLAB PM3 A device programmer from Microchip. Programs PIC18 microcontrollers and dsPIC digital signal controllers. Can be used with MPLAB IDE or stand-alone. Will obsolete PRO MATE II. MPLAB ICD 3 In-Circuit Debugger Microchip's in-circuit debuggers that works with MPLAB IDE. The MPLAB ICD 3 debugger supports PIC18F and PIC24 MCUs and dsPIC DSCs. The main component of each ICE is the pod. A complete system consists of a pod, a driver (and potentially a receiver) card, cables, and MPLAB IDE software. MPLAB SIM Microchip's simulator that works with MPLAB IDE in support of PIC MCU and dsPIC DSC devices. MPLIBTM Object Librarian Microchip's librarian that can work with MPLAB IDE. MPLIB librarian is an object librarian for use with COFF object modules created using either MPASM assembler (mpasm or mpasmwin v2.0) or MPLAB C17/C18 C compilers. MPLINKTM Object Linker MPLINK linker is an object linker for the Microchip MPASM assembler and the Microchip MPLAB C17 or C18 C compilers. MPLINK linker also may be used with the Microchip MPLIB librarian. MPLINK linker is designed to be used with MPLAB IDE, though it does not have to be. MRU Most Recently Used. Refers to files and windows available to be selected from MPLAB IDE main pull down menus. DS51766A-page 92 (c) 2008 Microchip Technology Inc. Glossary Nesting Depth The maximum level to which macros can include other macros. Node MPLAB IDE project component. Non Real Time Refers to the processor at a breakpoint or executing single-step instructions or MPLAB IDE being run in simulator mode. Non-Volatile Storage A storage device whose contents are preserved when its power is off. NOP No Operation. An instruction that has no effect when executed except to advance the program counter. Object Code The machine code generated by an assembler or compiler. Object File A file containing machine code and possibly debug information. It may be immediately executable or it may be relocatable, requiring linking with other object files, e.g., libraries, to produce a complete executable program. Object File Directives Directives that are used only when creating an object file. Off-Chip Memory Off-chip memory refers to the memory selection option for the PIC17 or PIC18 device where memory may reside on the target board, or where all program memory may be supplied by the debugger. The Memory tab accessed from Options>Development Mode provides the Off-Chip Memory selection dialog box. One-to-One Project-Workspace Model The most common configuration for application development in MPLAB IDE to is have one project in one workspace. Select Configure>Settings, Projects tab and check "Use one-to-one project-workspace model". Opcodes Operational Codes. See Mnemonics. Operators Symbols, like the plus sign `+' and the minus sign `-', that are used when forming well-defined expressions. Each operator has an assigned precedence that is used to determine order of evaluation. OTP One Time Programmable. EPROM devices that are not in windowed packages. Since EPROM needs ultraviolet light to erase its memory, only windowed devices are erasable. Pass Counter A counter that decrements each time an event (such as the execution of an instruction at a particular address) occurs. When the pass count value reaches zero, the event is satisfied. You can assign the Pass Counter to break and trace logic, and to any sequential event in the complex trigger dialog. PC Personal Computer or Program Counter. (c) 2008 Microchip Technology Inc. DS51766A-page 93 MPLAB(R) ICD 3 In-Circuit Debugger User's Guide PC Host Any PC running a supported Windows operating system. PIC MCUs PIC microcontrollers (MCUs) refers to all Microchip microcontroller families. PICSTART Plus A developmental device programmer from Microchip. Programs 8-, 14-, 28-, and 40-pin PIC microcontrollers. Must be used with MPLAB IDE software. Plug-ins The MPLAB IDE has both built-in components and plug-in modules to configure the system for a variety of software and hardware tools. Several plug-in tools may be found under the Tools menu. Pod MPLAB ICD 3 system: The box that contains the emulation control circuitry for the ICE device on the header or target board. An ICE device can be a production device with built-in ICE circuitry or a special ICE version of a production device (i.e., device-ICE). MPLAB ICD 2: The box that contains the debug control circuitry for the ICD device on the header or target board. An ICD device can be a production device with built-in ICD circuitry or a special ICD version of a production device (i.e., device-ICD). MPLAB ICE 2000/4000: The external debugger box that contains emulation memory, trace memory, event and cycle timers, and trace/breakpoint logic. Power-on-Reset Emulation A software randomization process that writes random values in data RAM areas to simulate uninitialized values in RAM upon initial power application. PRO MATE II No longer in Production. See the MPLAB PM3 device programmer. A device programmer from Microchip. Programs most PIC microcontrollers as well as most memory and KEELOQ devices. Can be used with MPLAB IDE or stand-alone. Profile For MPLAB SIM simulator, a summary listing of executed stimulus by register. Program Counter The location that contains the address of the instruction that is currently executing. Program Memory The memory area in a device where instructions are stored. Also, the memory in the debugger or simulator containing the downloaded target application firmware. Project A project contains the files needed to build an application (source code, linker script files, etc.) along with their associations to various build tools and build options. Prototype System A term referring to a user's target application, or target board. PWM Signals Pulse-Width Modulation Signals. Certain PIC MCU devices have a PWM peripheral. Qualifier An address or an address range used by the Pass Counter or as an event before another operation in a complex trigger. DS51766A-page 94 (c) 2008 Microchip Technology Inc. Glossary Radix The number base, hex, or decimal, used in specifying an address. RAM Random Access Memory (Data Memory). Memory in which information can be accessed in any order. Raw Data The binary representation of code or data associated with a section. Read Only Memory Memory hardware that allows fast access to permanently stored data but prevents addition to or modification of the data. Real Time When an in-circuit debugger or debugger is released from the halt state, the processor runs in Real-Time mode and behaves exactly as the normal chip would behave. In Real-Time mode, the real time trace buffer of an debugger is enabled and constantly captures all selected cycles, and all break logic is enabled. In an in-circuit debugger or debugger, the processor executes in real time until a valid breakpoint causes a halt, or until the user halts the execution. In the simulator, real time simply means execution of the microcontroller instructions as fast as they can be simulated by the host CPU. Real-Time Watch A Watch window where the variables change in real-time as the application is run. See individual tool documentation to determine how to set up a real-time watch. Not all tools support real-time watches. Recursion The concept that a function or macro, having been defined, can call itself. Great care should be taken when writing recursive macros; it is easy to get caught in an infinite loop where there will be no exit from the recursion. ROM Read Only Memory (Program Memory). Memory that cannot be modified. Run The command that releases the debugger from halt, allowing it to run the application code and change or respond to I/O in real time. Scenario For MPLAB SIM simulator, a particular setup for stimulus control. SFR See Special Function Registers. Shell The MPASM assembler shell is a prompted input interface to the macro assembler. There are two MPASM assembler shells: one for the DOS version and one for the Windows version. Simulator A software program that models the operation of devices. (c) 2008 Microchip Technology Inc. DS51766A-page 95 MPLAB(R) ICD 3 In-Circuit Debugger User's Guide Single Step This command steps though code, one instruction at a time. After each instruction, MPLAB IDE updates register windows, watch variables, and status displays so you can analyze and debug instruction execution. You can also single step C compiler source code, but instead of executing single instructions, MPLAB IDE will execute all assembly level instructions generated by the line of the high level C statement. Skew The information associated with the execution of an instruction appears on the processor bus at different times. For example, the executed opcodes appears on the bus as a fetch during the execution of the previous instruction, the source data address and value and the destination data address appear when the opcodes is actually executed, and the destination data value appears when the next instruction is executed. The trace buffer captures the information that is on the bus at one instance. Therefore, one trace buffer entry will contain execution information for three instructions. The number of captured cycles from one piece of information to another for a single instruction execution is referred to as the skew. Skid When a hardware breakpoint is used to halt the processor, one or more additional instructions may be executed before the processor halts. The number of extra instructions executed after the intended breakpoint is referred to as the skid. Source Code The form in which a computer program is written by the programmer. Source code is written in a formal programming language which can be translated into machine code or executed by an interpreter. Source File An ASCII text file containing source code. Special Function Registers The portion of data memory (RAM) dedicated to registers that control I/O processor functions, I/O status, timers or other modes or peripherals. Stack, Hardware Locations in PIC microcontroller where the return address is stored when a function call is made. Stack, Software Memory used by an application for storing return addresses, function parameters, and local variables. This memory is typically managed by the compiler when developing code in a high-level language. Static RAM or SRAM Static Random Access Memory. Program memory you can read/write on the target board that does not need refreshing frequently. Status Bar The Status Bar is located on the bottom of the MPLAB IDE window and indicates such current information as cursor position, development mode and device, and active tool bar. Step Into This command is the same as Single Step. Step Into (as opposed to Step Over) follows a CALL instruction into a subroutine. DS51766A-page 96 (c) 2008 Microchip Technology Inc. Glossary Step Over Step Over allows you to debug code without stepping into subroutines. When stepping over a CALL instruction, the next breakpoint will be set at the instruction after the CALL. If for some reason the subroutine gets into an endless loop or does not return properly, the next breakpoint will never be reached. The Step Over command is the same as Single Step except for its handling of CALL instructions. Step Out Step Out allows you to step out of a subroutine which you are currently stepping through. This command executes the rest of the code in the subroutine and then stops execution at the return address to the subroutine. Stimulus Input to the simulator, i.e., data generated to exercise the response of simulation to external signals. Often the data is put into the form of a list of actions in a text file. Stimulus may be asynchronous, synchronous (pin), clocked and register. Stopwatch A counter for measuring execution cycles. Symbol A symbol is a general purpose mechanism for describing the various pieces which comprise a program. These pieces include function names, variable names, section names, file names, struct/enum/union tag names, etc. Symbols in MPLAB IDE refer mainly to variable names, function names and assembly labels. The value of a symbol after linking is its value in memory. System Window Control The system window control is located in the upper left corner of windows and some dialogs. Clicking on this control usually pops up a menu that has the items "Minimize," "Maximize," and "Close." Target Refers to user hardware. Target Application Software residing on the target board. Target Board The circuitry and programmable device that makes up the target application. Target Processor The microcontroller device on the target application board. Template Lines of text that you build for inserting into your files at a later time. The MPLAB Editor stores templates in template files. Tool Bar A row or column of icons that you can click on to execute MPLAB IDE functions. Trace An debugger or simulator function that logs program execution. The debugger logs program execution into its trace buffer which is uploaded to MPLAB IDE's trace window. Trace Memory Trace memory contained within the debugger. Trace memory is sometimes called the trace buffer. (c) 2008 Microchip Technology Inc. DS51766A-page 97 MPLAB(R) ICD 3 In-Circuit Debugger User's Guide Trigger Output Trigger output refers to an debugger output signal that can be generated at any address or address range, and is independent of the trace and breakpoint settings. Any number of trigger output points can be set. Uninitialized Data Data which is defined without an initial value. In C, int myVar; defines a variable which will reside in an uninitialized data section. Upload The Upload function transfers data from a tool, such as an debugger or programmer, to the host PC or from the target board to the debugger. USB Universal Serial Bus. An external peripheral interface standard for communication between a computer and external peripherals over a cable using bi-serial transmission. USB 1.0/1.1 supports data transfer rates of 12 Mbps. Also referred to as high-speed USB, USB 2.0 supports data rates up to 480 Mbps. Warning An alert that is provided to warn you of a situation that would cause physical damage to a device, software file, or equipment. Watch Variable A variable that you may monitor during a debugging session in a Watch window. Watch Window Watch windows contain a list of watch variables that are updated at each breakpoint. Watchdog Timer A timer on a PIC microcontroller that resets the processor after a selectable length of time. The WDT is enabled or disabled and set up using Configuration bits. WDT See Watchdog Timer. Workbook For MPLAB SIM stimulator, a setup for generation of SCL stimulus. WorkSpace A workspace contains MPLAB IDE information on the selected device, selected debug tool and/or programmer, open windows and their location, and other IDE configuration settings. DS51766A-page 98 (c) 2008 Microchip Technology Inc. MPLAB(R) ICD 3 IN-CIRCUIT DEBUGGER USER'S GUIDE Index A E Abort Operation........................................................ 66 Animate .................................................................... 65 AVdd ........................................................................ 16 AVss......................................................................... 16 Erase........................................................................ 73 Erase All Before Programming................................. 37 Erase Flash Device .................................................. 66 Explorer 16 Demo Board.......................................... 29 B F Blank Check ............................................................. 73 Breakpoints Dialog................................................................ 68 Enabling............................................................ 67 Hardware ...............................................41, 63, 75 Setup .....................................................41, 63, 66 Software.................................................44, 63, 75 Build Configuration..............................................20, 58 Feature Support ....................................................... 11 Firmware Downloads ............................................... 75 Freeze on Halt.......................................................... 50 C Cables Length ..........................................................80, 82 Capacitors ...........................................................16, 17 CD-ROM .................................................................. 10 Circuits That Will Prevent the Debugger From Functioning ................................................. 17 Code Protect ............................................................ 18 CodeGuard Security ................................................ 77 Configuration Bits..........................................18, 27, 36 Creating a Hex File .................................................. 37 Customer Notification Service.................................... 5 Customer Support ...................................................... 6 D Debug Executive .......................................................... 19 Registers........................................................... 20 Debug Mode Sequence of Operations ................................... 18 Debug Read............................................................. 66 Debugger Menu ....................................................... 40 Debugging................................................................ 40 Demo Board............................................................. 39 Device and Feature Support .................................... 11 Documentation Conventions ........................................................ 3 Layout ................................................................. 1 Download Firmware ................................................. 75 Driver Board Standard ........................................................... 81 Durability, Card Guide.............................................. 80 (c) 2008 Microchip Technology Inc. G General Corrective Actions ...................................... 57 H Halt........................................................................... 65 Hardware Breakpoints.............................................. 41 Header Board Specification........................................................ 4 Hex File .................................................................... 37 Hibernate mode.............................................50, 51, 80 Hubs, USB ............................................................... 80 I ICD 3 Test Interface Board ................................ 10, 82 ICD Headers ............................................................ 10 ICD3Err0001 ............................................................ 53 ICD3Err0002 ............................................................ 53 ICD3Err0003 ............................................................ 53 ICD3Err0005 ............................................................ 53 ICD3Err0006 ............................................................ 53 ICD3Err0007 ............................................................ 53 ICD3Err0008 ............................................................ 53 ICD3Err0009 ............................................................ 53 ICD3Err0010 ............................................................ 53 ICD3Err0011 ............................................................ 53 ICD3Err0012 ............................................................ 54 ICD3Err0013 ............................................................ 54 ICD3Err0014 ............................................................ 54 ICD3Err0015 ............................................................ 54 ICD3Err0016 ............................................................ 54 ICD3Err0017 ............................................................ 54 ICD3Err0018 ............................................................ 54 ICD3Err0019 ............................................................ 54 ICD3Err0020 ............................................................ 54 ICD3Err0021 ............................................................ 54 ICD3Err0022 ............................................................ 54 ICD3Err0023 ............................................................ 54 ICD3Err0024 ............................................................ 54 ICD3Err0025 ............................................................ 54 ICD3Err0026 ............................................................ 54 ICD3Err0027 ............................................................ 54 DS51766A-page 99 MPLAB(R) ICD 3 In-Circuit Debugger User's Guide ICD3Err0028 ............................................................ 54 ICD3Err0029 ............................................................ 54 ICD3Err0030 ............................................................ 55 ICD3Err0031 ............................................................ 55 ICD3Err0032 ............................................................ 55 ICD3Err0033 ............................................................ 55 ICD3Err0034 ............................................................ 55 ICD3Err0035 ............................................................ 55 ICD3Err0036 ............................................................ 55 ICD3Err0037 ............................................................ 55 ICD3Err0038 ............................................................ 55 ICD3Err0039 ............................................................ 55 ICD3Err0040 ............................................................ 55 ICD3Err0041 ............................................................ 55 ICD3Err0045 ............................................................ 55 ICD3Err0046 ............................................................ 56 ICD3Err0047 ............................................................ 56 ICD3Err0052 ............................................................ 56 ICD3Err0053 ............................................................ 56 ICD3Err0054 ............................................................ 56 ICD3Err0055 ............................................................ 56 ICD3Err0056 ............................................................ 56 ICD3Err0057 ............................................................ 56 ICD3Err0063 ............................................................ 56 ICD3Err0064 ............................................................ 56 ICD3Err0065 ............................................................ 56 ICD3Err0066 ............................................................ 56 ICD3Err0067 ............................................................ 56 ICD3Err0068 ............................................................ 56 ICD3Err0069 ............................................................ 56 ICD3Err0070 ............................................................ 56 ICD3Err0071 ............................................................ 56 ICD3Err0072 ............................................................ 56 ICD3Err0073 ............................................................ 56 ICSP ........................................................18, 19, 20, 81 ICSPCLK .................................................................. 81 ICSPDAT.................................................................. 81 Indicator Lights ......................................................... 80 Internet Address ......................................................... 5 K Kit Components........................................................ 10 L LEDs .................................................................. 29, 80 Light Icons ................................................................ 30 Loading Program and Debug Code.......................... 39 M Microchip Internet Web Site ....................................... 5 Modular Interface Cable ........................................... 18 MPLAB C30 ............................................................. 33 MPLAB ICD 3 Defined................................................ 9 MPLAB IDE .............................................................. 21 DS51766A-page 100 P PC, Power Down .......................................... 50, 51, 80 PGC................................................... 15, 16, 17, 18, 19 PGD................................................... 15, 16, 17, 18, 19 PIC24FJ128GA010, Tutorial .................................... 29 PIM ........................................................................... 14 Port A ....................................................................... 29 Power-Down mode....................................... 50, 51, 80 Processor Extension Kits ......................................... 10 Program.............................................................. 66, 73 Program after successful build ................................. 74 Program Memory Tab .............................................. 37 Programming............................................................ 45 Programming Options .............................................. 36 Project Wizard .................................................... 26, 33 Pull-ups .................................................................... 17 R Read................................................................... 66, 73 Reading, Recommended............................................ 4 Readme...................................................................... 4 Reconnect ................................................................ 66 Reserved Resources by Device ............................... 20 Reset Processor .......................................................... 66 Resistors .................................................................. 17 Run........................................................................... 65 Run after successful program .................................. 74 Running code ........................................................... 40 S Secure Segments..................................................... 77 Selecting Device and Development Mode ............... 30 Set a Breakpoint....................................................... 41 Setting Program and Debug Options ....................... 38 Setting Up Hardware and Software.......................... 30 SMPS ....................................................................... 11 Software Breakpoints ............................................... 44 Standard Communication Connections ...................................................... 15 Driver Board ...................................................... 81 Standard ICSP Device Communication ................... 14 Step .......................................................................... 65 Stopwatch........................................................... 43, 63 T Table Read Protect .................................................. 18 Target Connection Circuitry ............................................................. 15 Improper Circuits............................................... 17 Standard............................................................ 15 Target Device ........................................................... 18 Timer1 ...................................................................... 29 Toolbar Buttons ........................................................ 40 Transition Socket...................................................... 10 Specification.................................................. 4, 23 Tutorial ..................................................................... 29 (c) 2008 Microchip Technology Inc. Index U USB.....................................................................80, 98 Cables............................................................... 10 Device Drivers .................................................. 21 Hubs ................................................................. 80 V Vcap ......................................................................... 16 Vdd.......................................................... 15, 16, 17, 18 Verify ........................................................................ 73 Vpp.................................................... 15, 16, 17, 18, 19 Vss .......................................................... 15, 16, 17, 18 W Warranty Registration ................................................ 4 Watch Window ......................................................... 42 Watchdog Timer..................................................18, 98 WWW Address........................................................... 5 (c) 2008 Microchip Technology Inc. DS51766A-page 101 WORLDWIDE SALES AND SERVICE AMERICAS ASIA/PACIFIC ASIA/PACIFIC EUROPE Corporate Office 2355 West Chandler Blvd. Chandler, AZ 85224-6199 Tel: 480-792-7200 Fax: 480-792-7277 Technical Support: http://support.microchip.com Web Address: www.microchip.com Asia Pacific Office Suites 3707-14, 37th Floor Tower 6, The Gateway Harbour City, Kowloon Hong Kong Tel: 852-2401-1200 Fax: 852-2401-3431 India - Bangalore Tel: 91-80-4182-8400 Fax: 91-80-4182-8422 India - New Delhi Tel: 91-11-4160-8631 Fax: 91-11-4160-8632 Austria - Wels Tel: 43-7242-2244-39 Fax: 43-7242-2244-393 Denmark - Copenhagen Tel: 45-4450-2828 Fax: 45-4485-2829 India - Pune Tel: 91-20-2566-1512 Fax: 91-20-2566-1513 France - Paris Tel: 33-1-69-53-63-20 Fax: 33-1-69-30-90-79 Japan - Yokohama Tel: 81-45-471- 6166 Fax: 81-45-471-6122 Germany - Munich Tel: 49-89-627-144-0 Fax: 49-89-627-144-44 Atlanta Duluth, GA Tel: 678-957-9614 Fax: 678-957-1455 Boston Westborough, MA Tel: 774-760-0087 Fax: 774-760-0088 Chicago Itasca, IL Tel: 630-285-0071 Fax: 630-285-0075 Dallas Addison, TX Tel: 972-818-7423 Fax: 972-818-2924 Detroit Farmington Hills, MI Tel: 248-538-2250 Fax: 248-538-2260 Kokomo Kokomo, IN Tel: 765-864-8360 Fax: 765-864-8387 Los Angeles Mission Viejo, CA Tel: 949-462-9523 Fax: 949-462-9608 Santa Clara Santa Clara, CA Tel: 408-961-6444 Fax: 408-961-6445 Toronto Mississauga, Ontario, Canada Tel: 905-673-0699 Fax: 905-673-6509 Australia - Sydney Tel: 61-2-9868-6733 Fax: 61-2-9868-6755 China - Beijing Tel: 86-10-8528-2100 Fax: 86-10-8528-2104 China - Chengdu Tel: 86-28-8665-5511 Fax: 86-28-8665-7889 Korea - Daegu Tel: 82-53-744-4301 Fax: 82-53-744-4302 China - Hong Kong SAR Tel: 852-2401-1200 Fax: 852-2401-3431 Korea - Seoul Tel: 82-2-554-7200 Fax: 82-2-558-5932 or 82-2-558-5934 China - Nanjing Tel: 86-25-8473-2460 Fax: 86-25-8473-2470 Malaysia - Kuala Lumpur Tel: 60-3-6201-9857 Fax: 60-3-6201-9859 China - Qingdao Tel: 86-532-8502-7355 Fax: 86-532-8502-7205 Malaysia - Penang Tel: 60-4-227-8870 Fax: 60-4-227-4068 China - Shanghai Tel: 86-21-5407-5533 Fax: 86-21-5407-5066 Philippines - Manila Tel: 63-2-634-9065 Fax: 63-2-634-9069 China - Shenyang Tel: 86-24-2334-2829 Fax: 86-24-2334-2393 Singapore Tel: 65-6334-8870 Fax: 65-6334-8850 China - Shenzhen Tel: 86-755-8203-2660 Fax: 86-755-8203-1760 Taiwan - Hsin Chu Tel: 886-3-572-9526 Fax: 886-3-572-6459 China - Wuhan Tel: 86-27-5980-5300 Fax: 86-27-5980-5118 Taiwan - Kaohsiung Tel: 886-7-536-4818 Fax: 886-7-536-4803 China - Xiamen Tel: 86-592-2388138 Fax: 86-592-2388130 Taiwan - Taipei Tel: 886-2-2500-6610 Fax: 886-2-2508-0102 China - Xian Tel: 86-29-8833-7252 Fax: 86-29-8833-7256 Thailand - Bangkok Tel: 66-2-694-1351 Fax: 66-2-694-1350 Italy - Milan Tel: 39-0331-742611 Fax: 39-0331-466781 Netherlands - Drunen Tel: 31-416-690399 Fax: 31-416-690340 Spain - Madrid Tel: 34-91-708-08-90 Fax: 34-91-708-08-91 UK - Wokingham Tel: 44-118-921-5869 Fax: 44-118-921-5820 China - Zhuhai Tel: 86-756-3210040 Fax: 86-756-3210049 01/02/08 DS51766A-page 102 (c) 2008 Microchip Technology Inc. Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: Microchip: DV164035