T-51750GD065J-FW-AB (AB) No. 2003-0198 OPTREX CORPORATION Page 1/20
LCD Module Technical Specification
T-51750GD065J-FW-AB
Table of Contents
1. Overview........................................................................................................................................................2
2. Absolute Maximum Ratings.................................................................................................................3
3. Electrical Characteristics ......................................................................................................................3
4. Interface Pin Connection .....................................................................................................................6
5. Interface Timing ........................................................................................................................................ 7
6. Block Diaglam..........................................................................................................................................10
7. Optical Characteristics.........................................................................................................................11
8. Inverted Scan Capability....................................................................................................................13
9. Mechanical Specifications..................................................................................................................14
10. Reliability Test Condition................................................................................................................... 16
11. Inspection Standards ...........................................................................................................................17
12. Code System of Production Lot ...................................................................................................18
13. Type Number ...........................................................................................................................................18
14. Applying Precautions ...........................................................................................................................18
15. Precautions Relating Product Handling..................................................................................... 19
16. Warranty .....................................................................................................................................................20
Revision History
Rev. Date Page Comment
Type No.
Oct 24, 2003
First Edition
Final Revision
******
Checked by (ACI Engineering Division)
Approved by (Quality Assurance Division)
Prepared by (Module Coordination Group)
T-51750GD065J-FW-AB (AB) No. 2003-0198 OPTREX CORPORATION Page 2/20
1. Overview
T-51750GD065J-FW-AB is 6.5” color TFT-LCD (Thin Film Transistor Liquid Crystal Display) module
composed of LCD panel, driver ICs, control circuit, and backlight unit.
By applying 6 bit digital data, 640 × 480, 260 K-color images are displayed on the 6.5” diagonal screen.
Input power voltage is 3.3 V or 5V for LCD driving.
Inverter for backlight is not included in this module. General specifications are summarized in the
following table:
ITEM SPECIFICATION
Display Area (mm) 132.5 (H) ×99.4 (V)
(6.5-inch diagonal)
Number of Dots 640 × 3 (H) ×480 (V)
Pixel Pitch (mm) 0.207 (H) × 0.207 (V)
Color Pixel Arrangement RGB vertical stripe
Display Mode Normally white
Number of Color 6bit, 262,144 colors
Contrast ratio 300
Optimum Viewing Angle(Contrast ratio) 6 o’clock
Brightness (cd/m2) 400
Module Size (mm) 158.0 (W) ×120.36 (H) ×11.55 (D)
Module Mass (g) 190(Typ)
Backlight Unit CCFL, 2-tubes, replaceable
Surface Treatment Anti-reflection and hard-coating (over 2H)
Attached Drawing Dimensional Outline UE-311848
Characteristic value without any note is typical value.
The LCD product described in this specification is designed and manufactured for the standard use
in OA equipment and consumer products, such as computers, communication equipment, industrial
robots, AV equipment and so on.
Do not use the LCD product for the equipment that require the extreme high level of reliability,
such as aerospace applications, submarine cables, nuclear power control systems and medical or
other equipment for life support.
OPTREX assumes no responsibility for any damage resulting from the use of the LCD product in
disregard of the conditions and handling precautions in this specification.
If customers intend to use the LCD product for the above items or other no standard items,
please contact our sales persons in advance.
T-51750GD065J-FW-AB (AB) No. 2003-0198 OPTREX CORPORATION Page 3/20
2. Absolute Maximum Ratings
ITEM SYMBOL MIN. MAX. UNIT
Power Supply Voltage for LCD VCC 0 5.5 V
Logic Input Voltage VI 0 7 V
Lamp Current IL 0 7.0 mArms
Lamp Frequency FL 40 80 kHz
Operation Temperature *1) Top 060°C
Storage Temperature *1) Tstg -25 70 °C
[Note]
*1) Top, Tstg 40°C: 90%RH max. without condensation
Top, Tstg > 40°C: Absolute humidity shall be less than the value of 90%RH at 40°C without
condensation.
3. Electrical Characteristics
(1) TFT- LCD Ambient Temperature : Ta = 25°C
ITEM SYMBOL MIN. TYP. MAX. UNIT Remarks
3.0 3.3 3.6 V for 3.3V system
Power Supply Voltages for LCD
Note A) VCC
4.5 5.0 5.5 V for 5V system
-- 240 -- mA for 3.3V system
Power Supply Currents for LCD
Note B) ICC
-- 180 -- mA for 5V system
-- -- 100 mVp-p VCC=+3.3V
Permissive input ripple Voltage VRP -- -- 100 mVp-p VCC=+5.0V
Logic Input Voltage High VIH 2.4 -- 5.5 V VCC=MAX
Low VIL 0 -- 0.8 V VCC=MIN
(2) Backlight Ta=25°C
ITEM SYMBOL MIN. TYP. MAX. UNIT Remarks
Lamp Voltage VL -- 320 -- Vrms IL=6.0mArms
Lamp Current IL -- 6.0 Note C) -- mArms *1)
Lamp Frequency FL 40 -- 80 kHz *2)
Starting Lamp Voltage VS -- -- 520 Vrms
Lamp Life Time LT 30000 -- -- h *3), IL=6.0mArms,
Continuous Operation
T-51750GD065J-FW-AB (AB) No. 2003-0198 OPTREX CORPORATION Page 4/20
*1) Lamp Current measurement method (The current meter is inserted in low voltage line.)
CTL
CTH
CTL
CTH
LCD
Module
A
Inverter Power
Supply
A
*2) Lamp frequency of inverter may produce interference with horizontal synchronous frequency, and
this may cause horizontal beat on the display. Therefore, please adjust lamp frequency, and keep
inverter as far from module as possible or use electronic shielding between inverter and module to
avoid the interference.
*3) Lamp life time is defined as the time either when the brightness becomes 50% of the initial value, or
when the starting lamp voltage does not meet the value specified in this table.
T-51750GD065J-FW-AB (AB) No. 2003-0198 OPTREX CORPORATION Page 5/20
[Note]
A) Power and signals sequence:
t1 10 ms 200 ms < t6
0 < t2 50 ms 0 t7
0 < t3 50 ms
0 < t4 50 ms
500 ms < t5
t1 t2 t3
data
3.0V or 4.5V
3.0V or 4.5V
0.3V
VCC
t4 t5
t6 t7
Backlight
data
: R
G
B DATA
,
D
C
LK
,
HD
,
VD
,
DENA
0.3V 0.3V
VCC-dip conditions:
1) When 2.4 V VCC < 3.0 V, td 10 ms
2) When VCC < 2.4 V
VCC-dip conditions should also follow the power and signals sequence.
td
2.4 V
3.0 V or 4.5V
VCC
B) Typical current condition:
64- gray- bar-pattern
480 line mode
VCC = +3.3 V, fH=31.5kHz, fV=60Hz, fCLK= 25MHz
VCC = +5.0 V, fH=31.5kHz, fV=60Hz, fCLK= 25MHz
C) For typical luminance of 400 cd/m2
T-51750GD065J-FW-AB (AB) No. 2003-0198 OPTREX CORPORATION Page 6/20
4. Interface Pin Connection
CN 1(INTERFACE SIGNAL)
Used connector: DF9B-31P-1V (Hirose)
Corresponding connector: DF9B-31S-1V (Hirose)
Pin No. S
y
mbol Function
1 GND
2 DCLK Clock signal for sampling catch data signal
3 HD Horizontal sync signal
4VD
Vertical sync signal
5 GND
6 R0 Red data signal(LSB)
7 R1 Red data signal
8 R2 Red data signal
9 R3 Red data signal
10 R4 Red data si
g
nal
11 R5 Red data signal(MSB)
12 GND
13 G0 Green data signal(LSB)
14 G1 Green data signal
15 G2 Green data signal
16 G3 Green data signal
17 G4 Green data signal
18 G5 Green data signal(MSB)
19 GND
20 B0 Blue data signal(LSB)
21 B1 Blue data signal
22 B2 Blue data signal
23 B3 Blue data signal
24 B4 Blue data signal
25 B5 Blue data signal(MSB)
26 GND
27 DENA Data enable signal(to settle the viewing area)
28 VCC Power Supply (DC 3.3V or 5V)
29 VCC Power Supply (DC 3.3V or 5V)
30 TEST This pin should be open. Test signal output for only internal test use.
31 REV Reverse scan control. L = Normal, H = Reverse
*) The shielding case is connected with GND
CN 2, CN 3 (BACKLIGHT)
Backlight-side connector: BHR-02(8.0)VS-1N(JST)
Inverter-side connector: SM02(8.0)B-BHS(JST)
Pin No. S
y
mbol Function
1 CTH VBLHHi
g
h Volta
g
e
3 CTL VBLLLow Voltage
     [Note] VBLH-VBLL = VL
T-51750GD065J-FW-AB (AB) No. 2003-0198 OPTREX CORPORATION Page 7/20
5. Interface Timing
(1) Timing Specifications
ITEM SYMBOL MIN. TYP. MAX. UNIT
Frequency fCLK 20 25 30 MHz
Period tCLK 33.3 40 50 ns
Low Width tWCL 10 -- -- ns
DCLK
High Width tWCH 10 -- -- ns
Set up time tDS 5 ----ns
DATA
(R,G,B,DENA,
HD, VD) Hold time tDH 5 ----ns
Horizontal Active Time tHA 640 640 640 tCLK
Horizontal Front Porch tHFP 0----t
CLK
Horizontal Back Porch tHBP 7----t
CLK
Vertical Active Time tVA 480 480 480 tH
Vertical Front Porch tVFP 120-- t
H
DENA
Vertical Back Porch tVBP 820-- t
H
Frequency fH27 31.5 38 kHz
Period tH26.3 31.7 37.0 µsHD
Low Width tWHL 5----t
CLK
Frequency fV55 60 70 Hz
Period tV14.3 16.7 18.2 msVD
Low Width tWVL 3----t
H
[Note]
1) DATA is latched at fall edge of DCLK in this timing specification.
2) Polarities of HD and VD are negative in this specification.
3) DENA (Data Enable) should always be positive polarity as shown in the timing specification.
4) DCLK should appear during all invalid period, and HD should appear during invalid period of
frame cycle.
5) Accepted only 640 data and 480 lines.
6) Both HREV and VREV should be stable during operation.
T-51750GD065J-FW-AB (AB) No. 2003-0198 OPTREX CORPORATION Page 8/20
(2) Timing Chart
(3) Color Data Assignment
a. Pixel Timing Chart
0.7VCC
0.3VCC
tWCH tWCL
tCLK
tDtD
DCLK
DATA(R,G,B),
DENA, HD, VD
0.3VCC
0.7VCC
DCLK
DATA
(R,G,B) 1 2 639 6403Invalid Data Invalid Data
tHA
tHFP tHBP
tWHL
tH=1/fH
First Data
L
ast
D
ata
DENA
HD
b. Horizontal Timing Chart
c. Vertical Timing Chart
1 2 479 4803Invalid Data Invalid Data
tWVL
tVFP tVBP
tV=1/fV
LINE DATA
D
DENA
HD
tVA
T-51750GD065J-FW-AB (AB) No. 2003-0198 OPTREX CORPORATION Page 9/20
R DATA G DATA B DATA
COLOR INPUT R5 R4 R3 R2 R1 R0 G5 G4 G3 G2 G1 G0 B5 B4 B3 B2 B1 B0
DATA MS
B
LSB MS
B
LSB MS
B
LSB
BLACK 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
RED(63) 1 1 1 1 1 1 0 0 0 0 0 0 0 0 0 0 0 0
GREEN(63) 0 0 0 0 0 0 1 1 1 1 1 1 0 0 0 0 0 0
BASIC BLUE(63) 0 0 0 0 0 0 0 0 0 0 0 0 1 1 1 1 1 1
COLOR CYAN 0 0 0 0 0 0 1 1 1 1 1 1 1 1 1 1 1 1
MAGENTA 1 1 1 1 1 1 0 0 0 0 0 0 1 1 1 1 1 1
YELLOW 1 1 1 1 1 1 1 1 1 1 1 1 0 0 0 0 0 0
WHITE 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
RED(0) 000000000000000000
RED (1) 0 0 0 0 0 1 0 0 0 0 0 0 0 0 0 0 0 0
RED(2) 000010000000000000
RED
RED (62) 1 1 1 1 1 0 0 0 0 0 0 0 0 0 0 0 0 0
RED(63) 1 1 1 1 1 1 0 0 0 0 0 0 0 0 0 0 0 0
GREEN(0) 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
GREEN (1) 0 0 0 0 0 0 0 0 0 0 0 1 0 0 0 0 0 0
GREEN(2) 0 0 0 0 0 0 0 0 0 0 1 0 0 0 0 0 0 0
GREEN
GREEN(62) 0 0 0 0 0 0 1 1 1 1 1 0 0 0 0 0 0 0
GREEN(63) 0 0 0 0 0 0 1 1 1 1 1 1 0 0 0 0 0 0
BLUE(0) 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
BLUE(1) 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1
BLUE(2) 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 0
BLUE
BLUE(62) 0 0 0 0 0 0 0 0 0 0 0 0 1 1 1 1 1 0
BLUE(63) 0 0 0 0 0 0 0 0 0 0 0 0 1 1 1 1 1 1
[Note]
1) Definition of gray scale
Color (n) --- n indicates gray scale level.
Higher n means brighter level.
2) Data 1:High, 0: Low
T-51750GD065J-FW-AB (AB) No. 2003-0198 OPTREX CORPORATION Page 10/20
6. Block Diaglam
I/F Connector
Timing
Converter
Driver(source)
TFT-LCD
Driver(gate)
Power
Supply
Circuit
BACKLIGHT
CCFL
1
3
CN2, 3
G1
G2
G480
Timing signal
Display data
S1
S2
S1919
S1920
Power
CN1
T-51750GD065J-FW-AB (AB) No. 2003-0198 OPTREX CORPORATION Page 11/20
7. Optical Characteristics
Ta=25°C, VCC=3.3V, Input Signals: Typ. Values shown in Section 5
ITEM SYMBOL CONDITION MIN. TYP. MAX. UNIT Remarks
Contrast Ratio CR Best viewing -- 300 -- -- *1)*3)
Luminance Lw θ = φ = 0° -- 400 -- cd/m2*2)*3)
Response Time tr θ = φ = 0° -- 15 -- ms *3)*4)
tf θ = φ = 0° -- 16 -- ms *3)*4)
Viewing Horizontal φCR 10 -- -5555 -- ° *3)
Angle Vertical θ-- -6030 -- ° *3)
Image Sticking tis 2 h -- -- 2 s *5)
Red Rx -- 0.55 --
Ry -- 0.34 --
Color Green Gx -- 0.31 --
Coordinates Gy θ = φ = 0° -- 0.56 -- -- *3)
Blue Bx -- 0.15 --
By -- 0.17 --
White Wx -- 0.31 --
Wy -- 0.36 --
[Note]
These items are measured using BM-5A (TOPCON) or LCD-7000 (Otsuka Electronic) under the dark
room condition (no ambient light).
Condition: IL = 6.0 mArms, FL=58kHz
*1) Definition of Contrast Ratio
CR=ON (White) Luminance / OFF (Black) Luminance: average of 5 points
*2) Definition of Luminance
Lw= ON (White) Luminance: average of 5 points
(1,1) 160 320 480
120
240
360
(640,480)
2
4
5
3
1
MEASUREMENT POINT
T-51750GD065J-FW-AB (AB) No. 2003-0198 OPTREX CORPORATION Page 12/20
*3) Definition of Viewing Angle(θ , φ)
*4) Definition of Response Time
White
90%90%
10%10% Black tf
tr
Luminance
*5) Image Sticking
Continuously display the test pattern shown in the figure below for two-hours. Then display a
completely white screen. The previous image shall not persist more than two seconds at 25°C.
TEST PATTERN FOR IMAGE STICKING TEST
Black
Lines
White
Area
Cols 318-322
Rows 238-242
T-51750GD065J-FW-AB (AB) No. 2003-0198 OPTREX CORPORATION Page 13/20
8. Inverted Scan Capability
This module has the capability of inverting scan direction by signaling from controller.
Both horizontal and vertical scan direction can be selected independently. Note that scan direction
cannot be changed during operation.
The following figure shows the relation between the display position and the scan direction.
DISPLAY POSITION
Normal scan: REV = “L
D( 1, 1) D( 2, 1) --- D( X, 1) --- D(639, 1) D(640, 1)
D( 1, 2) D( 2, 2) --- D( X, 2) --- D(639, 2) D(640, 2)
¦ ¦ +++¦ ¦
D( 1, Y) D( 2, Y) --- D( X, Y) --- D(639, Y) D(640, Y)
¦ ¦ +++¦ ¦
D( 1,479) D( 2,479) --- D( X,479) --- D(639,479) D(640,479)
D( 1,480) D( 2,480) --- D( X,480) --- D(639,480) D(640,480)
Reverse scan: REV = H
D(640,480) D(639,480) --- D( X,480) --- D( 2,480) D( 1,480)
D(640,479) D(639,479) --- D( X,479) --- D( 2,479) D( 1,479)
¦ ¦ +++¦ ¦
D(640, Y) D(639, Y) --- D( X, Y) --- D( 2, Y) D( 1, Y)
¦ ¦ +++¦ ¦
D(640, 2) D(639, 2) --- D( X, 2) --- D( 2, 2) D( 1, 2)
D(640, 1) D(639, 1) --- D( X, 1) --- D( 2, 1) D( 1, 1)
The following drawing shows the relationship between the viewing direction and the scan direction.
Normal scan Reverse scan
D(1,1) D(640,1)
D(1,480) D(640,480)
      
D(1,1) D(640,1)
D(1,480) D(640,480)