Page 1 of 2
The information contained herein does not form part of a
contract and is subject to change without notice. ARCOL
operate a policy of continual product development, therefore,
specifications may change.
It is the responsibility of the customer to ensure that the
component selected from our range is suitable for the intended
application. If in doubt please ask ARCOL.
ARCOL UK Limited,
Threemilestone Ind. Estate,
Truro, Cornwall, TR4 9LG, UK.
T +44 (0) 1872 277431
F +44 (0) 1872 222002
E sales@arcolresistors.com
www.arcolresistors.com
12/14.08
HS Aluminium Housed Resistors
Manufactured in line with the requirements of MIL 18546 and
IEC 115, designed for direct heatsink mounting with thermal
compound to achieve maximum performance.
High Power to volume
Wound to maximise High Pulse Capability
Values from R005 to 100K
Custom designs welcome
RoHS Compliant
Characteristics
Tolerance (Code):
Tolerance for low Ω values:
Temperature coefficients:
Insulation resistance (Dry):
Power dissipation:
Ohmic values:
Low inductive (NHS):
NHS ohmic value:
NHS working volts:
Standard ±5% (J) and ±10% (K). Also available ±1% (F), ±2% (G) and ±3% (H)
Typically ≥ R05 ±5% ≤ R047 ±10%
Typical values < 1K 100ppm Std. > 1K 25ppm Std. For lower TCRs please contact Arcol
10,000 MΩ minimum
At high ambient temperature dissipation derates linearly to zero at 200°C
From R005 to 100K depending on wattage size
Specify by adding N before HS Series code, e.g. NHS50
Divide standard HS maximum value by 4
Divide standard HS maximum working voltage by 1.414
Ordering Procedure
Standard Resistor. To specify standard: Series, Watts, Ohmic
Value, Tolerance Code, e.g.: HS25 2R2 J
Non Inductive Resistor. To specify add N, e.g.: NHS100 10R J
Heat Dissipation
Heat dissipation: Whilst the use of proprietary heat sinks
with lower thermal resistances is acceptable, uprating is not
recommended. For maximum heat transfer it is recommended
that a heat sink compound be applied between the resistor
base and heat sink chassis mounting surface. It is essential that
the maximum hot spot temperature of 200°C is not exceeded,
therefore, the resistor must be mounted on a heat sink of
correct thermal resistance for the power being dissipated.
Temp. Rise & Power Dissipation
Surface temperature of resistor related to power dissipation.
The resistor is standard heatsink mounted using a proprietary
heatsink compound.
HS300
HS250
HS200
HS150
HS50
HS75
HS25
HS15
HS10
HS100
0 20 50 75 100 150 200 250 300
POWER DISSIPATION (WATTS)
200
100
5
SURFACE TEMPERATURE RISE(˚C)
Page 2 of 2 12/14.08
HS Aluminium Housed Resistors
Electrical Specifications
Size
Style
MIL-R
18546
Power
rating
on std.
heatsink
@25°C
Watts
with no
heatsink
@25°C
Resis-
tance
range
Limiting
element
voltage
Voltage
proof AC
Peak
Voltage
proof AC
rms.
Approx
weight
gms
Typical
surface
rise HS
mounted
Standard heatsink
cm2Thickness
mm
HS10 RE 60 10 5 R005-10K 160 1400 1000 4 5.8 415 1
HS15 RE 65 15 7 R005-10K 265 1400 1000 7 5.1 415 1
HS25 RE 70 25 9 R005-36K 550 3500 2500 14 4.2 535 1
HS50 RE 75 50 14 R01-86K 1250 3500 2500 32 3.0 535 1
HS75 75 24 R01-50K 1400 6363 4500 85 1. 1 995 3
HS100 100 30 R01-70K 1900 6363 4500 115 1. 0 995 3
HS150 150 45 R01-10 0K 2500 6363 4500 175 1. 0 995 3
HS200 200 50 R01-50K 1900 7070 5000 475 0.7 3750 3
HS250 250 55 R01-50K 2200 7070 5000 600 0.6 4765 3
HS300 300 60 R01-68K 2500 7070 5000 700 0.6 5780 3
HS10-HS300 Standard Resistor
HS 200, 250, 300
6mm
AG
J
L
F
B
Ø 2.0
±
0.25
2. 0.1
HS 10, 15, 25, 50
D
H
K
C
HS 75, 100, 150
=
Ø 3.2
max.
3.0 ±
0.1
*
=
Centre hole in
150 Watts only
E
B
F
J
L
A
==
B
F
EE
M
J
L
A
D
H
K
C
D
H
K
C
GG
Dimensions (mm)
Size A Max B Max C Max D Max E Max F±0.3 G±0.3 H Max J Max K Max L ±0.25* M Max
HS10 16.5 30.0 8.8 8.5 15.9 11. 3 12.4 4.5 2.4 1. 8 2.4
HS15 21.0 36.5 11. 0 11. 2 19.9 14.3 15.9 5.5 2.8 1. 8 2.4
HS25 28.0 51.0 14.8 14.2 27.3 18.3 19.8 7. 7 5.2 2.6 3.2
HS50 28.0 72.5 14.8 14.2 49.1 39.7 21.4 8.4 5.2 2.6 3.2
HS75 47.5 72.0 24.1 27.3 48.7 29.0 37.0 11. 8 10.4 3.7 4.4
HS100 47.5 88.0 24.1 27.3 65.2 35.0 37.0 11. 8 15.4 3.7 4.4
HS150 47.5 121.0 24.1 27.3 97.7 58.0 37.0 11. 8 20.4 3.7 4.4
HS200 72.5 145.7 41.8 45.5 89.7 70.0 57.2 20.5 10.4 5.5 5.1 103.4
HS250 72.5 167.0 41.8 45.5 109.7 89.0 57.2 20.5 10.4 5.5 5.1 122.4
HS300 72.5 184.4 41.8 45.5 127.7 104.0 59.0 20.5 12.4 5.5 6.6 141.4
* HS200-HS300 Watts is ± 0.45