95
GT11 Series
GT 5 GT 13 GT 16 PO5G GT 11 GT 14 GT 17 GT 19 GT 3 GT 6W GT 7 GT 10 GT 18W GT 15 GT 8 GT 9 GT 25
Coaxial cable connection of Antennas, Sensors, and Communication Trunk Lines
Strip the cable.
Cut the shield and expose the wire.
Cut back the shield above the sheath and wrap with
conductive tape.
Strip the wire and form it.
Crimp the wire to the internal terminal.
Jig used: Automatic crimping machine.
(Refer to Page 103 for detail.)
Insert the internal terminals into the Outer terminals.
Crimp the Outer terminal.
Jig used: Outside tube caulking jig.
(Refer to Page 103 for detail.)
Insert the terminal into the housing.
(Please insert until the terminal is stopped by the lance.)
Mount the retainer to complete the task.
Refer to Page 96 for information
about the retainer mounting
method.
BTermination sequence
Cable
Shield
Wire
Conductor
1mm max.
The shield must be visible.
The joined side of the crimp portion faces upward
(for both male and female).
The product information in this catalog is for reference only. Please request the Engineering Drawing for the most current and accurate design information.
All non-RoHS products have been discontinued, or will be discontinued soon. Please check the products status on the Hirose website RoHS search at www.hirose-connectors.com, or contact your Hirose sales representative.