Series ZSE30/ISE30
2-Color Display High-Precision Digital Pressure Switch
®
Abnormal conditions can be detected at a glance!
SET
kPa
PRESSURE
OUT
SET
kPa
PRESSURE
OUT
SET
kPa
PRESSURE
OUT
SET
kPa
PRESSURE
OUT
SET
kPa
PRESSURE
OUT
With One-touch fitting (ø4, ø6, ø5/32", ø1/4")
Reduced dimensions in piping direction
2-color digital display allows you to choose the setting according to your application
requirements. 4 different display settings are available.
17.8 mm reduction
Straight type
12.4 mm reduction
Elbow type
Comparison when One-touch fittings (KQ2H06-M5 / KQ2L06-M5) are connected to the piping ports (M5 x 0.8)
14.4
32.2
22.4
34.8
12.4 mm17.8 mm
KQ2H06-M5 KQ2L06-M5
Red GreenRed Green
Red RedRed Red
Green RedGreen Red
Green GreenGreen Green
This photo shows 2 display
colors simultaneously for
product presentation
purposes. In actual
application, only one color is
displayed at a time.
695
ZSP
PS
ISA
PSE
IS
ISG
ZSM
ZSE
ISE
P0694-P0755-E.qxd 08.8.27 6:29 PM Page 695
This function allows uniformity in the numbers displayed.
Vacuum/Low pressure (ZSE30) Positive pressure (ISE30)
Blue Gray
Space-saving improvement
Economical use of space
High-precision
resolution: 1/1000
Switches for vacuum and positive
pressure can be easily distinguished.
The different display panel frame colors easily tell them apart.
Variations
Applicable
panel thickness is
up to 6 mm.
(Panel mounting)
With analog output
Display calibration
Old Model
ZSE4E
ISE4E
Old Model
New Model
New Model
ZSE30
ISE30
126
40
Rated pressure
range
Setting/Display resolution
0.2 kPa 0.001 MPa
Output
Switch output
NPN/PNP open collector (1 output)
Analog output
Voltage output: 1 to 5 V; Current output: 4 to 20 mA
Current consumption
45 mA or less (70 mA or less for current output)
Option Panel mount/Bracket
Vacuum/Low pressure
ZSE30
Positive pressure
ISE30
100 kPa
–100 kPa
0
1 MPa
0
More user-friendly controls
103.5
34.5
Each display required its own panel opening.
Just one panel opening is
required for stackable
displays, which can be
mounted either horizontally
or vertically.
Compact profile
Plug-type
connectors take the
burden out of
wiring work and
maintenance.
Raised rubber
button controls are
clearly set apart,
simple to operate,
soft to the touch.
In addition to the conventional voltage output
type (1 to 5 V)
Current output type
(4 to 20 mA)
is now available.
• Convenient when longer wiring is required
• Excellent noise resistance
696
P0694-P0755-E.qxd 08.8.27 6:29 PM Page 696
ZSE30 01
ISE30 01
25 M
25 M
How to Order
Option Part No.
When optional parts are required separately, use the following part
numbers to place an order.
Option Part no.
ZS-27-A
ZS-27-B
ZS-27-C
ZS-27-D
ZS-27-01
Note
Lead wire length: 2 m
With mounting screws
(M3 x 5L: 2 pcs.)
With M3 x 8L (2 pcs.)
With M3 x 8L (2 pcs.)
1 pc.
Lead wire with connector
Bracket
Panel mount adapter
Panel mount adater + Front protective cover
Front protective cover
For vacuum/low pressure
For positive pressure
Unit specifications
Nil
M
With unit switching function
Fixed SI unit (International System of Units) Note)
Note) Fixed unit:
For vacuum/Low pressure: kPA
For positive pressure: MPa
NPN output
PNP output
1 to 5 V output
4 to 20 mA output
Output specifications
25
65
26
28
Option 2
Nil
A
None
Bracket
B
D
Panel mount
Panel mount adapter +
Front protective
cover
Without lead wire
Lead wire with connector
(Lead wire length: 2 m)
Option 1
Nil
L
R 1/8
(With M5 female thread)
NPT 1/8
(With M5 female thread)
ø4 One-touch fitting
ø5/32" One-touch fiting
ø6 One-touch fitting
ø1/4" One-touch fitting
ø4 One-touch fitting
ø5/32" One-touch fitting
ø6 One-touch fitting
ø1/4" One-touch fitting
01
T1
C4H
C6H
N7H
C4L
C6L
N7L
Piping specifications
Elbow type
Straight type
697
®®
2-Color Display
High-Precision Digital Pressure Switch
Series ZSE30/ISE30
ZSP
PS
ISA
PSE
IS
ISG
ZSM
ZSE
ISE
P0694-P0755-E.qxd 08.8.27 6:29 PM Page 697
Specifications
Model
Rated pressure range
Regulating pressure range
Extended analog output range
Proof pressure
Min. regulating unit
Fluid
Power supply voltage
Current consumption
Switch output Note 1)
Repeatability
Analog
output
Hysteresis
Display
Max. load current
Max. applied voltage
Residual voltage
Response time
Short circuit protection
Voltage output
Current output
Hysteresis mode
Window comparator mode
ZSE30 (Vacuum/Low pressure)
–100.0 to 100.0 kPa
–101.0 to 101.0 kPa
500 kPa
0.2 kPa
±0.2% F.S. ±2 digit or less
ISE30 (Positive pressure)
0.000 to 1.000 MPa
–0.100 to 1.000 MPa
–0.100 to 0 Mpa
1.5 MPa
0.001 MPa
±0.2% F.S. ±1 digit or less
Air, Inert gas, Non-flammable gas
12 to 24 VDC±10%, Ripple (p-p) 10% or less (With power supply polarity protection)
45 mA or less (at no load)
NPN or PNP open collector output: 1 output
80 mA
30 V (With NPN output)
1 V or less (With load current of 80 mA)
2.5 ms or less (Response time selections with anti-chattering function: 20, 160, 640, 1280 ms)
Ye s
Output voltage: 1 to 5 V ±2.5% F.S. or less (With rated pressure range)
0.6 to 1 V ±5% F.S. or less (Extended analog output range)
Linearity: ±1% F.S. or less, Output impedance: Approx. 1 kΩ
Output current: 4 to 20 mA ±2.5% F.S. or less (With rated pressure range)
2.4 to 4 mA ±5% F.S. or less (Extended analog output range)
Linearity: ±1% F.S. or less
Maximum load impedance: 300 Ω with power supply voltage of 12 V;
600 Ω with power supply voltage of 24 V
Minimum load impedance: 50 Ω
Adjustable (can be set from 0)
3 1/2 digit, 7-segment indicator, 2-color display (Red and green)
Sampling cycle: 5 times/s
Light up when output is ON (Green)
±2% F.S. or less (based on 25°C)
IP40
Operating: 0 to 50°C, Stored: –10 to 60°C (No freezing or condensation)
Operating and stored: 35 to 85% RH (No condensation)
1000 VAC for 1 min. between live parts and enclosure
50 MΩ or more between live parts and enclosure (at 500 VDC)
10 to 150 Hz, 1.5 mm or 20 m/s2 amplitude in X, Y, Z directions for 2 hours each (De-energized)
100 m/s2 in X, Y, Z directions 3 times each (De-energized)
Oil-resistant vinyl cabtire cable 3 cores ø3.4 2 m
Cross section: 0.2 mm2 Insulator O.D.: 1.12 mm
Compliant with CE Marking and UL (CSA) standards
Note 1) When switch output is selected, analog output is not available.
Note 2)
When voltage output is selected, a simultaneous selection of switch output and current output is not available.
Note 3)
When current output is selected, a simultaneous selection of switch output and voltage output is not available.
Note 4) With lead wire with a connector (ZS-27-A)
Enclosure
Operating temperature range
Operating humidity range
Withstand voltage
Insulation resistance
Vibration resistance
Impact resistance
Environmental
resistance
Piping Specifications
Part no.
Port
size
Wetted part material
Mass
One-touch fitting
Straight type
One-touch fitting
Elbow type
With lead wire with connector (2 m)
Without lead wire with connector
01
R 1/8
M5 x 0.8
81 g
43 g
T1
NPT 1/8
M5 x 0.8
C4H
ø4 mm
ø5/32 inch
C6H
ø6 mm
O-ring: NBR
76 g
38 g
N7H
ø1/4 inch
Sensor pressure receiving area: Silicon, Piping port: C3602 (Electroless nickel plated), O-ring: HNBR
C4L
ø4 mm
ø5/32 inch
C6L
ø6 mm
O-ring: NBR, fitting: PBT
78 g
40 g
N7L
ø1/4 inch
Function
Various additional functions are available for easy measurement, switch operation and confirmation of measured values suitable for the
conditions of the measured fluid.
Anti-chattering function
Key lock function
Peak hold function
Bottom hold function
Zero-out function
Unit conversion
Prevents possible malfunction due to sudden fluctuations in the primary pressure by adjusting the response time.
Key operation can be locked to prevent any incorrect function of the operation switch.
Can retain the maximum pressure value displayed during measurement.
Can retain the minimum pressure value displayed during measurement.
The pressure display can be set at zero when the pressure is open to the atmosphere.
Can convert the display value.
Display accuracy
Indicator light
Temperature characteristics
Lead wire Note 4)
Standard
±2% F.S. ±1 digit (at 25°C ambient temperature)±2% F.S. ±2 digit (at 25°C ambient temperature)
Note 3)
Note 2)
698
Series ZSE30/ISE30
P0694-P0755-E.qxd 08.8.27 6:29 PM Page 698
Error
description
over-
current
error
Residual
pressure
error
Applied
pressure
error
System
error
LCD
display Condition Solution
Take the following corrective solutions when errors occur.
Load current of switch
output is more than 80 mA.
Pressure is applied during the
zero out operation as follows:
When the switch for positive
pressure is used: ±0.071 MPa
or more.
When the switch positive
pressure is used:
±7.1 kPa or more.
After displaying for 3 seconds,
it will return to the measuring
mode.
Supply pressure exceeds
the maximum regulating
pressure.
Supply pressure is below
the minimum regulating
pressure.
Shut off the power
supply. After eliminating
the output factor that
caused the excess
current, turn the power
supply back on.
Bring the pressure
back to atmospheric
pressure and try
using the zero out
function.
Reduce/Increase
supply pressure to
within the regulating
pressure range.
Shut off the power
supply. Turn the
power supply back
on.
If the power should
not come back on,
please contact SMC
for an inspection.
SET
MPa
PRESSURE
OUT
Description
Error Correction Example of Internal Circuit and Wiring
Indication light (Green) LCD display
DOWN button
Displays the switch operation status.
UP button
SET button
-25
NPN open collector output
Maximum 30 V, 80 mA
Residual voltage:
1 V or less
-26
Analog output type
1 to 5 V (±2.5% F.S.)
Output impedance:
1 kΩ
-28
Analog output type
4 to 20 mA (±2.5% F.S.)
Maximum load impedance:
Power supply voltage 12 V: 300 Ω
Power supply voltage 24 V: 600 Ω
Minimum load impedance: 50 Ω
-65
PNP open collector
Maximum 80 mA
Displays the current pressure
condition, setting mode
conditions, selected display unit,
and error codes. A display color
type can be selected from either a
single color display with red or
green, or 2-color display in which
green and red are switched
according to the output.
Use this button to change the
mode or increase the ON/OFF set
value. It also allows you to switch
to the peak value display mode.
Use this button to switch the
mode and set the set value.
Use this button to change the
mode or decrease the ON/OFF
set value. It also allows you to
switch to the bottom value display
mode.
Internal data error
Internal data error
Internal data error
Internal data error
+
+
+
+
Load
Brown DC(+)
Black OUT
Blue DC(–)
Load
Brown DC(+)
Black OUT
(Analog output)
Blue DC(–)
Main circuit
Load
Brown DC(+)
Black OUT
(Analog output)
Blue DC(–)
Brown DC(+)
Black OUT
Blue DC(–)
Load
12
to
24 VDC
Main circuit Main circuitMain circuit
12
to
24 VDC
12
to
24 VDC
12
to
24 VDC
699
High-Precision Digital Pressure Switch
Series ZSE30/ISE30
2-Color Display
ZSP
PS
ISA
PSE
IS
ISG
ZSM
ZSE
ISE
P0694-P0755-E.qxd 08.8.27 6:29 PM Page 699
Dimensions
SET
MPa
PRESSURE
OUT
SMC
1.5
Width across flats 12
8
3.6
9.525
10
30
20 ±0.1
20 ±0.1
01: R 1/8
T1: NPT 1/8
2 x M3 x 0.5
Thread depth 4
Lead wire
with connector
M5 x 0.8
A
øB
C
A
øB
With One-touch fitting
Straight Elbow
One-touch fitting
size
ø4, ø5/32"
ø6
ø1/4"
Straight
A
14.4
B
11.2
A
20
22.4
22.8
B
10.4
12.8
13.2
C
18
20
20.5
(mm)
Elbow
With bracket
20
20
30
35 35
1.8
45
42.5
10
3
22
15
4.2
SMC
25
30
700
Series ZSE30/ISE30
P0694-P0755-E.qxd 08.8.27 6:29 PM Page 700
Dimensions
Panel mount adapter + Front protective cover
R4.5
R4.5
34.5 47.8
21
MADE IN JAPAN
817.87.2
8.75
9.5
Panel thickness 0.5 to 6
SET
MPa
PRESSURE
OUT
11
34.5
42.4
Panel thickness 0.5 to 6
17.8 8 9.5
Panel mount
701
High-Precision Digital Pressure Switch
Series ZSE30/ISE30
2-Color Display
ZSP
PS
ISA
PSE
IS
ISG
ZSM
ZSE
ISE
P0694-P0755-E.qxd 08.8.27 6:29 PM Page 701
SET
MPa
PRESSURE
OUT
SET
MPa
PRESSURE
OUT
SET
MPa
PRESSURE
OUT
SET
MPa
PRESSURE
OUT
SET
MPa
PRESSURE
OUT
SET
MPa
PRESSURE
OUT
Dimensions
Panel fitting dimension
MADE IN JAPAN
MADE IN JAPAN
MADE IN JAPANMADE IN JAPAN
MADE IN JAPAN
MADE IN JAPAN
31 x n pcs. + 3.5 x (n pcs. – 1)
31
24 and up
0
–0.4
31 24 and up
31 x n pcs. + 3.5 x (n pcs. – 1)
0
–0.4
0
0.4
31
1-pc. mounting Multiple (2 pcs. or more) horizontal mounting
Multiple (2 pcs. or more) vertical mounting
702
Series ZSE30/ISE30
P0694-P0755-E.qxd 08.8.27 6:29 PM Page 702
Series ZSE30/ISE30
Specific Product Precautions 1
Be sure to read before handling. Refer to front matters 58 and 59 for Safety Instructions
and pages 687 to 691 for Pressure Switch Precautions.
1. Do not drop, bump, or apply excessive
impacts (980 m/s2) while handling. Although
the body of the sensor may not be damaged,
the internal parts of the sensor could be
damaged and lead to a malfunction.
2.
The tensile strength of the cord is 35 N.
Applying a greater pulling force on it can
cause a malfunction. When handling, hold
the body of the sensor––do not dangle it
from the cord.
3. Do not exceed the screw-in torque of 7 to 9
Nm when installing piping. Exceeding this
value may cause malfunctioning of the
sensor.
4. Do not use pressure sensors with toxic,
corrosive and/or flammable gases.
5. Allow a sufficient margin of tube length in
piping in order to prevent application of
torsional, tensile or moment load to the
tubes and fittings.
6. When a brand of tubing other than SMC is
used, make sure that the tolerance of the
tube’s O.D. satisfies the following
specifications.
1) Nylon tubing: ±0.1 mm or less
2) Soft nylon tubing: ±0.1 mm or less
3) Polyurethane tubing: +0.15 mm or less, –0.2 mm or less
7. The applicable fluid is air. Please consult
with SMC if the switch is to be used with
other types of fluids.
Warning
Handling
1. Incorrect wiring can damage the switch and
cause a malfunction or erroneous switch
output. Connections should be done while
the power is turned off.
2. Do not attempt to insert or pull the
connector when the power is on. A switch
output malfunction may occur.
3. Wire separately from power lines and high
voltage lines, avoiding wiring in the same
conduit with these lines. Malfunctions may
occur due to noise from these other lines.
4. If a commercial switching regulator is used,
make sure that the F.G. terminal is
grounded.
Connection
Warning
1. Our pressure switches are CE marked;
however, they are not equipped with surge
protection against lightning. Lightning surge
countermeasures should be applied directly
to system components as necessary.
2. Our pressure switches do not have an
explosion proof rating. Never use in the
presence of an explosive gas as this may
cause a serious explosion.
3. Do not use in an environment where static
electricity can cause problems, otherwise
system failure or malfunction may result.
Operating Environment
Warning
2. Mounting with bracket
Mount a bracket to the body using two M3 x 5L mounting
screws and install on piping with hexagon socket head cap
screws. The switch can be installed horizontally depending on
the installation location.
Caution
Mounting
Tightening torque for bracket mounting
screw should be 0.5 to 0.7 Nm.
1. Mounting with panel mount adapter
To release push the
clips outward as shown
on the picture, and pull
back towards you.
Panel mount
adapter
Mounting screw
M3 x 5L
Bracket
Panel mount
adapter
Panel
Claw
703
ZSP
PS
ISA
PSE
IS
ISG
ZSM
ZSE
ISE
P0694-P0755-E.qxd 08.8.27 6:29 PM Page 703
Connection/Removal of Connector
Lever
Lead wire (Brown)
Lead wire (Black)
Lead wire (Blue)
DC polarity indicator
To connect the connector, insert it straight while
pinching the lever, and then push the lever into the jack
of the housing and lock it.
To remove the connector, pull it straight out while
applying pressure with your thumb to the lever and
unhooking it from the jack.
Do not attempt to insert or pull the connector when the
power is on. A switch output malfunction may occur.
• Cut the tube perpendicularly.
Hold the tube and insert it into the One-touch fitting
carefully and securely all the way to the bottom.
Piping
Tube
One-touch fitting
Regulating Pressure Range and Rated Pressure Range
Set the pressure within the rated pressure range.
The regulating pressure range is the range of pressure that is possible in setting.
The rated pressure range is the range of pressure that satisfies the specifications (accuracy, linearity, etc.) on the sensor.
Although it is possible to set a value outside the rated pressure range, the specifications will not be guaranteed even if the value stays
within the regulating pressure range.
Switch –100 kPa 0 100 kPa 500 kPa 1 MPa
Pressure range
For vacuum/
low pressure
For positive
pressure
ZSE30
ISE30
Rated pressure range of switch
Regulating pressure range of switch
–100 kPa
–101 kPa
100 kPa
101 kPa
1 MPa
–100 kPa
(–0.1 MPa)
1 MPa
0
Caution
Series ZSE30/ISE30
Specific Product Precautions 2
Be sure to read before handling. Refer to front matters 58 and 59 for Safety Instructions
and pages 687 to 691 for Pressure Switch Precautions.
704