Specifications
Model
Rated pressure range
Regulating pressure range
Extended analog output range
Proof pressure
Min. regulating unit
Fluid
Power supply voltage
Current consumption
Switch output Note 1)
Repeatability
Analog
output
Hysteresis
Display
Max. load current
Max. applied voltage
Residual voltage
Response time
Short circuit protection
Voltage output
Current output
Hysteresis mode
Window comparator mode
ZSE30 (Vacuum/Low pressure)
–100.0 to 100.0 kPa
–101.0 to 101.0 kPa
—
500 kPa
0.2 kPa
±0.2% F.S. ±2 digit or less
ISE30 (Positive pressure)
0.000 to 1.000 MPa
–0.100 to 1.000 MPa
–0.100 to 0 Mpa
1.5 MPa
0.001 MPa
±0.2% F.S. ±1 digit or less
Air, Inert gas, Non-flammable gas
12 to 24 VDC±10%, Ripple (p-p) 10% or less (With power supply polarity protection)
45 mA or less (at no load)
NPN or PNP open collector output: 1 output
80 mA
30 V (With NPN output)
1 V or less (With load current of 80 mA)
2.5 ms or less (Response time selections with anti-chattering function: 20, 160, 640, 1280 ms)
Ye s
Output voltage: 1 to 5 V ±2.5% F.S. or less (With rated pressure range)
0.6 to 1 V ±5% F.S. or less (Extended analog output range)
Linearity: ±1% F.S. or less, Output impedance: Approx. 1 kΩ
Output current: 4 to 20 mA ±2.5% F.S. or less (With rated pressure range)
2.4 to 4 mA ±5% F.S. or less (Extended analog output range)
Linearity: ±1% F.S. or less
Maximum load impedance: 300 Ω with power supply voltage of 12 V;
600 Ω with power supply voltage of 24 V
Minimum load impedance: 50 Ω
Adjustable (can be set from 0)
3 1/2 digit, 7-segment indicator, 2-color display (Red and green)
Sampling cycle: 5 times/s
Light up when output is ON (Green)
±2% F.S. or less (based on 25°C)
IP40
Operating: 0 to 50°C, Stored: –10 to 60°C (No freezing or condensation)
Operating and stored: 35 to 85% RH (No condensation)
1000 VAC for 1 min. between live parts and enclosure
50 MΩ or more between live parts and enclosure (at 500 VDC)
10 to 150 Hz, 1.5 mm or 20 m/s2 amplitude in X, Y, Z directions for 2 hours each (De-energized)
100 m/s2 in X, Y, Z directions 3 times each (De-energized)
Oil-resistant vinyl cabtire cable 3 cores ø3.4 2 m
Cross section: 0.2 mm2 Insulator O.D.: 1.12 mm
Compliant with CE Marking and UL (CSA) standards
Note 1) When switch output is selected, analog output is not available.
Note 2)
When voltage output is selected, a simultaneous selection of switch output and current output is not available.
Note 3)
When current output is selected, a simultaneous selection of switch output and voltage output is not available.
Note 4) With lead wire with a connector (ZS-27-A)
Enclosure
Operating temperature range
Operating humidity range
Withstand voltage
Insulation resistance
Vibration resistance
Impact resistance
Environmental
resistance
Piping Specifications
Part no.
Port
size
Wetted part material
Mass
One-touch fitting
Straight type
One-touch fitting
Elbow type
With lead wire with connector (2 m)
Without lead wire with connector
01
R 1/8
M5 x 0.8
—
—
81 g
43 g
T1
NPT 1/8
M5 x 0.8
—
—
C4H
—
ø4 mm
ø5/32 inch
—
C6H
—
ø6 mm
—
O-ring: NBR
76 g
38 g
N7H
—
ø1/4 inch
—
Sensor pressure receiving area: Silicon, Piping port: C3602 (Electroless nickel plated), O-ring: HNBR
C4L
—
—
ø4 mm
ø5/32 inch
C6L
—
—
ø6 mm
O-ring: NBR, fitting: PBT
78 g
40 g
N7L
—
—
ø1/4 inch
Function
Various additional functions are available for easy measurement, switch operation and confirmation of measured values suitable for the
conditions of the measured fluid.
Anti-chattering function
Key lock function
Peak hold function
Bottom hold function
Zero-out function
Unit conversion
Prevents possible malfunction due to sudden fluctuations in the primary pressure by adjusting the response time.
Key operation can be locked to prevent any incorrect function of the operation switch.
Can retain the maximum pressure value displayed during measurement.
Can retain the minimum pressure value displayed during measurement.
The pressure display can be set at zero when the pressure is open to the atmosphere.
Can convert the display value.
Display accuracy
Indicator light
Temperature characteristics
Lead wire Note 4)
Standard
±2% F.S. ±1 digit (at 25°C ambient temperature)±2% F.S. ±2 digit (at 25°C ambient temperature)
Note 3)
Note 2)
698
Series ZSE30/ISE30
P0694-P0755-E.qxd 08.8.27 6:29 PM Page 698