Mixed Domain Oscilloscopes
MDO4000B Series Datasheet
Introducing the world's first oscilloscope that includes a logic analyzer,
spectrum analyzer and protocol analyzer - all synchronized for an
integrated view. Although you can use the MDO4000B Series simply as a
mixed signal oscilloscope or as a spectrum analyzer, the real power comes
from the integration of the two. For the first time ever, you can see how
your designs perform in both the time and frequency domains on a single
instrument. View the RF spectrum at any point in time to see how it
changes over time or with device state. Solve the most complicated design
issues, quickly and efficiently, with an oscilloscope as integrated as your
design.
Winner of 13 industry awards
Key performance specifications
4 analog channels
1 GHz, 500 MHz, 350 MHz, and 100 MHz bandwidth models
Up to 20 M record length on all channels
>340,000 wfm/s maximum waveform capture rate
16 digital channels
MagniVu high-speed acquisition provides 60.6 ps fine timing
resolution
1 spectrum analyzer channel
9 kHz to 3 GHz or 9 kHz to 6 GHz frequency range models
Ultra-wide capture bandwidth ≥1 GHz
Standard passive voltage probes with 3.9 pF capacitive loading and
500 MHz or 1 GHz analog bandwidth
Key features
Mixed signal design and analysis
Automated triggering, decode, and search on serial and parallel
buses
Per-channel threshold settings
Multichannel setup and hold triggering
Spectral analysis
Dedicated front-panel controls for commonly performed tasks
Automated peak markers identify frequency and amplitude of
spectrum peaks
Manual markers
Trace types include: Normal, Average, Max Hold, and Min Hold
Detection types include: +Peak, -Peak, Average, and Sample
Spectrogram display for insight into slowly changing RF
phenomena
Automated measurements include: Channel Power, Adjacent
Channel Power Ratio (ACPR), and Occupied Bandwidth (OBW)
Trigger on RF power level
Mixed-domain and analysis
Time-correlated analog, digital, and RF signal acquisitions in a
single instrument
Wave Inspector® controls provide easy navigation of time-
correlated data from both the time and frequency domains
Amplitude, frequency, and phase vs. time waveforms derived from
spectrum analyzer input
Selectable spectrum time to see how RF spectrum changes over
time - even on a stopped acquisition
www.tektronix.com 1
Optional serial triggering and analysis - serial protocol trigger, decode,
and search for I2C, SPI, USB, Ethernet, CAN, LIN, FlexRay,
RS-232/422/485/UART, MIL-STD-1553, and I2S/LJ/RJ/TDM
264 mm (10.4 inches) bright XGA color display
Small footprint and lightweight - Only 147 mm (5.8 inches) deep and
5 kg (11 lb.)
Connectivity
Two USB 2.0 host ports on the front panel and two on the rear panel
for quick and easy data storage and connecting a USB keyboard
USB 2.0 device port on the rear panel for easy connection to a PC or
direct printing to a PictBridge®-compatible printer
Integrated 10/100/1000BASE-T Ethernet port for network connection
and video out port to export the oscilloscope display to a monitor or
projector
Optional application support
Advanced RF triggering
Power analysis
Limit and mask testing
HDTV and custom video analysis
Vector signal analysis
Need more performance?
Need more bandwidth or record length?
Need jitter analysis?
Need to make serial bus compliance measurements?
Consider the MSO/DPO5000B Series oscilloscopes, with leading performance and
analysis for more advanced design verification. www.tektronix.com/MSO5000
▪ Up to 2 GHz bandwidth
▪ Up to 250 M record length
▪ Automated jitter measurements standard
▪ Over 20 optional measurement applications available
Introducing the Mixed Domain Oscilloscope
The MDO4000B Series is the world's first oscilloscope with a built in
spectrum analyzer. This integration enables you to continue to use your
debug tool of choice, the oscilloscope, to investigate frequency domain
issues rather than having to find and re-learn a spectrum analyzer.
However, the power of the MDO4000B Series goes well beyond simply
observing the frequency domain as you would on a spectrum analyzer. The
real power is in its ability to correlate events in the frequency domain with
the time domain phenomena that caused them.
When both the spectrum analyzer and any analog or digital channels are
on, the oscilloscope display is split into two views. The upper half of the
display is a traditional oscilloscope view of the Time Domain. The lower half
of the display is a Frequency Domain view of the spectrum analyzer input.
Note that the Frequency Domain view is not simply an FFT of the analog or
digital channels in the instrument, but is the spectrum acquired from the
spectrum analyzer input.
Datasheet
2 www.tektronix.com
Another key difference is that with traditional oscilloscope FFTs, you can
typically either get the desired view of the FFT display, or the desired view
of your other time domain signals of interest, but never both at the same
time. This is because traditional oscilloscopes only have a single
acquisition system with a single set of user settings such as record length,
sample rate, and time per division that drive all data views. But with the
MDO4000B Series, the spectrum analyzer has its own acquisition system
that is independent, but time correlated, to the analog and digital channel
acquisition systems. This allows each domain to be configured optimally,
providing a complete time correlated system view of all analog, digital, and
RF signals of interest.
The spectrum shown in the Frequency Domain view is taken from the
period of time indicated by the short orange bar in the time domain view –
known as the Spectrum Time. With the MDO4000B Series, Spectrum Time
can be moved through the acquisition to investigate how the RF spectrum
changes over time. And this can be done while the oscilloscope is live and
running or on a stopped acquisition.
The upper half of the MDO4000B Series display shows the Time Domain view of the
analog and digital channels, while the lower half shows the Frequency Domain view of
the spectrum analyzer channel. The orange bar - Spectrum Time - shows the period of
time used to calculate the RF spectrum.
Figures 1 through 4 show a simple everyday application – tuning of a PLL.
This application illustrates the powerful connection between the time
domain and the frequency domain that the MDO4000B Series provides.
With its wide capture bandwidth and ability to move Spectrum Time
throughout the acquisition, this single capture includes the same spectral
content as approximately 1,500 unique test setups and acquisitions on a
traditional spectrum analyzer. For the first time ever, correlating events,
observing interactions, or measuring timing latencies between the two
domains is exceptionally easy, giving you quick insight to your design’s
operation.
Figure 1 - Time and Frequency Domain view showing the turn-on of a PLL. Channel
1 (yellow) is probing a control signal that enables the VCO. Channel 2 (cyan) is probing
the VCO tune voltage. The SPI bus which is programming the PLL with the desired
frequency is probed with three digital channels and automatically decoded. Notice
Spectrum Time is placed after the VCO was enabled and coincident with the command
on the SPI bus telling the PLL the desired frequency of 2.400 GHz. Note that the RF is at
2.5564 GHz when the circuit turns on.
Figure 2 - Spectrum Time is moved about 90 μs to the right. At this point, the spectrum
shows that the PLL is in the process of tuning to the correct frequency (2.400 GHz). It
has made it down to 2.4924 GHz.
Mixed Domain Oscilloscopes — MDO4000B Series
www.tektronix.com 3
Figure 3 - Spectrum Time is moved another 160 μs to the right. At this point the spectrum
shows that the PLL has actually overshot the correct frequency and gone all the way
down to 2.3888 GHz.
Figure 4 - The PLL eventually settles on the correct 2.400 GHz frequency about 320 μs
after the VCO was enabled.
Built on the award-winning MSO4000B Series
of Mixed Signal Oscilloscopes
The MDO4000B Series provides you with the same comprehensive set of
features available in the MSO4000B Mixed Signal Oscilloscope Series.
This robust set of tools will help you speed through every stage of
debugging your design - from quickly discovering an anomaly and capturing
it, to searching your waveform record for the event and analyzing its
characteristics and your device's behavior.
Discover
To debug a design problem, first you must know it exists. Every design
engineer spends time looking for problems in their design, a time-
consuming and frustrating task without the right debug tools.
The industry’s most complete visualization of signals provides fast insight
into the real operation of your device. A fast waveform capture rate –
greater than 340,000 waveforms per second with FastAcq – enables you
to see glitches and other infrequent transients within seconds, revealing the
true nature of device faults. A digital phosphor display with color- and
intensity-grading shows the history of a signal’s activity by using color or
intensity in areas of the signal that occur more frequently, providing a visual
display of just how often anomalies occur.
Discover Digital phosphor technology with FastAcq enables greater than
340,000 wfms/s waveform capture rate and real-time color-intensity grading.
Capture
Discovering a device fault is only the first step. Next, you must capture the
event of interest to identify root cause.
Accurately capturing any signal of interest begins with proper probing. Low-
capacitance probes are included with the oscilloscope, one for each analog
channel. These industry-first high-impedance passive voltage probes have
3.9 pF of capacitive loading to minimize the effect of the probe on your
circuit's operation, offering the performance of an active probe with the
flexibility of a passive probe.
Datasheet
4 www.tektronix.com
A complete set of triggers - including runt, timeout, logic, pulse width/glitch,
setup/hold violation, serial packet, and parallel data - help you quickly find
your event. With up to a 20M point record length, you can capture many
events of interest, even thousands of serial packets, in a single acquisition
for further analysis while maintaining high resolution to zoom in on fine
signal details.
From triggering on specific packet content to automatic decode in multiple
data formats, the oscilloscope provides integrated support for the industry's
broadest range of serial buses - I2C, SPI, USB, Ethernet, CAN, LIN,
FlexRay, RS-232/422/485/UART, MIL-STD-1553, and I2S/LJ/RJ/TDM. The
ability to decode up to four serial and/or parallel buses simultaneously
means you gain insight into system-level problems quickly.
To further help troubleshoot system-level interactions in complex
embedded systems, the oscilloscope offers 16 digital channels in addition
to its analog channels. Since the digital channels are fully integrated into
the oscilloscope, you can trigger across all input channels, automatically
time correlating all analog, digital, serial, and RF signals. The MagniVu
high-speed acquisition on these channels enables you to acquire fine signal
detail (up to 60.6 ps resolution) around the trigger point for precision timing
measurements. MagniVu is essential for making accurate timing
measurements for setup and hold, clock delay, signal skew, and glitch
characterization.
Capture Triggering on a specific transmit data packet going across a SPI bus. A
complete set of triggers, including triggers for specific serial packet content, ensures you
quickly capture your event of interest.
Search
Finding your event of interest in a long waveform record can be time
consuming without the right search tools. With today’s record lengths
pushing beyond a million data points, locating your event can mean
scrolling through thousands of screens of signal activity.
The innovative Wave Inspector® controls give you the industry’s most
comprehensive search and waveform navigation capability. These controls
speed panning and zooming through your record. With a unique force-
feedback system, you can move from one end of your record to the other in
just seconds. User marks allow you to mark any location that you may want
to reference later for further investigation. Or, automatically search your
record for criteria you define. Wave Inspector will instantly search your
entire record, including analog, digital, serial-bus, and RF-versus-time data.
Along the way it will automatically mark every occurrence of your defined
event so you can quickly move between events.
Search RS-232 decode showing results from a Wave Inspector search for data value
"n". Wave Inspector controls provide unprecedented efficiency in viewing and navigating
waveform data.
Analyze
Verifying that your prototype’s performance matches simulations and meets
the project’s design goals requires analyzing its behavior. Tasks can range
from simple checks of rise times and pulse widths to sophisticated power
loss analysis and investigation of noise sources.
The MDO4000B Series offers a comprehensive set of integrated analysis
tools including waveform- and screen-based cursors, automated
measurements, advanced waveform math including arbitrary equation
editing, spectral math, FFT analysis, and trend plots for visually determining
how a measurement is changing over time. Specialized application support
for serial bus analysis, power supply design, and video design and
development is also available.
Mixed Domain Oscilloscopes — MDO4000B Series
www.tektronix.com 5
Analyze – Waveform histogram of a falling edge showing the distribution of edge position
(jitter) over time. Included are numeric measurements made on the waveform histogram
data. A comprehensive set of integrated analysis tools speeds verification of your
design's performance.
Digital phosphor technology with FastAcq
Digital phosphor technology with FastAcq provides you with fast insight into
the real operation of your device. Its fast waveform capture rate – greater
than 340,000 wfms/s – gives you a high probability of quickly seeing the
infrequent problems common in digital systems: runt pulses, glitches, timing
issues, and more.
To further enhance the visibility of rarely occurring events, intensity grading
is used to indicate how often rare transients are occurring relative to normal
signal characteristics. There are four waveform palettes available in
FastAcq acquisition mode.
The Temperature palette uses color-grading to indicate frequency of
occurrence with hot colors like red/yellow indicating frequently
occurring events and colder colors like blue/green indicating rarely
occurring events.
The Spectral palette uses color-grading to indicate frequency of
occurrence with colder colors like blue indicating frequently occurring
events and hot colors like red indicating rarely occurring events.
The Normal palette uses the default channel color (like yellow for
channel one) along with gray-scale to indicate frequency of occurrence
where frequently occurring events are bright.
The Inverted palette uses the default channel color along with gray-
scale to indicate frequency of occurrence where rarely occurring events
are bright.
These color palettes quickly highlight the events that over time occur more
often or, in the case of infrequent anomalies, occur less often.
Infinite or variable persistence choices determine how long waveforms stay
on the display, helping you to determine how often an anomaly is occurring.
Digital phosphor technology enables a greater than 340,000 wfm/s waveform capture
rate and real-time intensity grading.
Accurate high-speed probing
The TPP Series probes, included standard with every MDO4000B Series
oscilloscope, provide up to 1 GHz of analog bandwidth, and 3.9 pF of
capacitive loading. The extremely low capacitive loading minimizes adverse
effects on your circuits and is more forgiving of longer ground leads. And,
since the probe bandwidth matches or exceeds your oscilloscope
bandwidth, you can see the high-frequency components in your signal
which is critical for high-speed applications. The TPP Series passive
voltage probes offer all the benefits of general-purpose probes like high
dynamic range, flexible connection options, and robust mechanical design,
while providing the performance of active probes. In addition, a low-
attenuation, 2X version of the TPP probes is available for measuring low
voltages. Unlike other low-attenuation passive probes, the TPP0502 has
high bandwidth (500 MHz) as well as low capacitive loading (12.7 pF).
Mixed signal design and analysis
The MDO4000B provides 16 digital channels which are tightly integrated
into the oscilloscope's user interface. This simplifies operation and makes it
possible to solve mixed-signal issues easily.
Datasheet
6 www.tektronix.com
The MDO4000B Series provides 16 integrated digital channels enabling you to view and
analyze time-correlated analog and digital signals.
Color-coded digital waveform display
This oscilloscope has redefined the way you view digital waveforms. One
common problem shared by both logic analyzers and mixed-signal
oscilloscopes is determining if data is a one or a zero when zoomed in far
enough that the digital trace stays flat all the way across the display. Color-
coded digital traces display ones in green and zeros in blue.
The multiple transition detection hardware shows you a white edge on the
display when the system detects multiple transitions. White edges indicate
that more information is available by zooming in or acquiring at faster
sampling rates. In most cases zooming in will reveal the pulse that was not
viewable with the previous settings. If the white edge is still present after
zooming in as far as possible, this indicates that increasing the sample rate
on the next acquisition will reveal higher frequency information than the
previous settings could acquire.
You can group digital waveforms and enter waveform labels by using a
USB keyboard. By simply placing digital waveforms next to each other, they
form a group.
With color-coded digital waveform display, groups are created by simply placing digital
channels together on the screen, allowing digital channels to be moved as a group. You
can set threshold values for each channel, enabling support for up to 16 different logic
families.
Once a group is formed, you can position all the channels contained in that
group collectively. This greatly reduces the normal setup time associated
with positioning channels individually.
MagniVu® high-speed acquisition
The main digital acquisition mode on the MSO4000B Series will capture up
to 20M points at 500 MS/s (2 ns resolution). In addition to the main record,
the oscilloscope provides an ultra high-resolution record called MagniVu
which acquires 10,000 points at up to 16.5 GS/s (60.6 ps resolution). Both
main and MagniVu waveforms are acquired on every trigger and can be
switched between in the display at any time, running or stopped. MagniVu
provides significantly finer timing resolution than comparable MSOs on the
market, instilling confidence when making critical timing measurements on
digital waveforms.
The MagniVu high-resolution record provides 60.6 ps timing resolution, enabling you to
make critical timing measurements on your digital waveforms.
Mixed Domain Oscilloscopes — MDO4000B Series
www.tektronix.com 7
P6616 MSO probe
This unique probe design offers two eight-channel pods. Each channel
ends with a probe tip featuring a recessed ground for simplified connection
to the device under test. The coax on the first channel of each pod is
colored blue making it easy to identify. The common ground uses an
automotive-style connector making it easy to create custom grounds for
connecting to the device under test. When connecting to square pins, the
P6616 has an adapter that attaches to the probe head extending the probe
ground flush with the probe tip so you can attach to a header. The P6616
offers outstanding electrical characteristics, having only 3 pF of capacitive
loading, a 100 kΩ input resistance, and is capable of acquiring toggle rates
>500 MHz and pulses as short as 1 ns in duration.
The P6616 MSO probe offers two eight-channel pods to simplify connecting to your
device.
Visualizing changes in your RF signal
The time domain graticule on the MDO4000B Series display provides
support for three RF time domain traces that are derived from the
underlying I and Q data of the spectrum analyzer input including:
Amplitude - The instantaneous amplitude of the spectrum analyzer
input vs. time
Frequency - The instantaneous frequency of the spectrum analyzer
input, relative to the center frequency vs. time
Phase - The instantaneous phase of the spectrum analyzer input,
relative to the center frequency vs. time
Each of these traces may be turned on and off independently, and all three
may be displayed simultaneously. RF time domain traces make it easy to
understand what's happening with a time-varying RF signal.
The orange waveform in the Time Domain view is the frequency vs. time trace derived
from the spectrum analyzer input signal. Notice that Spectrum Time is positioned during
a transition from the highest frequency to the lowest frequency, so the energy is spread
across a number of frequencies. With the frequency vs. time trace, you can easily see
the different frequency hops, simplifying characterization of how the device switches
between frequencies.
Datasheet
8 www.tektronix.com
Advanced triggering with analog, digital and
spectrum analyzer channels
In order to deal with the time-varying nature of modern RF applications, the
MDO4000B Series provides a triggered acquisition system that is fully
integrated with the analog, digital and spectrum analyzer channels. This
means that a single trigger event coordinates acquisition across all
channels, allowing you to capture a spectrum at the precise point in time
where an interesting time domain event is occurring. A comprehensive set
of time domain triggers are available, including Edge, Sequence, Pulse
Width, Timeout, Runt, Logic, Setup/Hold Violation, Rise/Fall Time, Video,
and a variety of parallel and serial bus packet triggers. In addition, you can
trigger on the power level of the spectrum analyzer input. For example, you
can trigger on your RF transmitter turning on or off.
The optional MDO4TRIG application module provides advanced RF
triggering. This module enables the RF power level on the spectrum
analyzer to be used as a source for Sequence, Pulse Width, Timeout, Runt,
and Logic trigger types. For example, you can trigger on a RF pulse of a
specific length or use the spectrum analyzer channel as an input to a logic
trigger, enabling the oscilloscope to trigger only when the RF is on while
other signals are active.
Fast and accurate spectral analysis
When using the spectrum analyzer input by itself, the MDO4000B Series
display becomes a full-screen Frequency Domain view.
Key spectral parameters such as Center Frequency, Span, Reference
Level, and Resolution Bandwidth are all adjusted quickly and easily using
the dedicated front-panel menus and keypad.
MDO4000B frequency domain display.
Key spectral parameters are adjusted quickly with the dedicated front-panel menus and
keypad.
Intelligent, efficient markers
In a traditional spectrum analyzer, it can be a very tedious task to turn on
and place enough markers to identify all your peaks of interest. The
MDO4000B Series makes this process far more efficient by automatically
placing markers on peaks that indicate both the frequency and the
amplitude of each peak. You can adjust the criteria that the oscilloscope
uses to automatically find the peaks.
The highest amplitude peak is referred to as the reference marker and is
shown in red. Marker readouts can be switched between Absolute and
Delta readouts. When Delta is selected, marker readouts show each peak's
delta frequency and delta amplitude from the reference marker.
Two manual markers are also available for measuring non-peak portions of
the spectrum. When enabled, the reference marker is attached to one of
the manual markers, enabling delta measurements from anywhere in the
spectrum. In addition to frequency and amplitude, manual marker readouts
also include noise density and phase noise readouts depending on whether
Absolute or Delta readouts are selected. A "Reference Marker to Center"
function instantly moves the frequency indicated by the reference marker to
center frequency.
Mixed Domain Oscilloscopes — MDO4000B Series
www.tektronix.com 9
Automated peak markers identify critical information at a glance. As shown here, the five
highest amplitude peaks that meet the threshold and excursion criteria are automatically
marked along with the peak's frequency and amplitude.
Spectrogram
The MDO4000B Series includes a spectrogram display which is ideal for
monitoring slowly changing RF phenomena. The x-axis represents
frequency, just like a typical spectrum display. However, the y-axis
represents time, and color is used to indicate amplitude.
Spectrogram slices are generated by taking each spectrum and "flipping it
up on its edge" so that it's one pixel row tall, and then assigning colors to
each pixel based on the amplitude at that frequency. Cold colors (blue,
green) are low amplitude and hotter colors (yellow, red) are higher
amplitude. Each new acquisition adds another slice at the bottom of the
spectrogram and the history moves up one row. When acquisitions are
stopped, you can scroll back through the spectrogram to look at any
individual spectrum slice.
Spectrogram display illustrates slowly moving RF phenomena. As shown here, a signal
that has multiple peaks is being monitored. As the peaks change in both frequency and
amplitude over time, the changes are easily seen in the Spectrogram display.
Triggered versus Free Run operation
When both the time and frequency domains are displayed, the spectrum
shown is always triggered by the system trigger event and is time
correlated with the active time-domain traces. However, when only the
frequency domain is displayed, the spectrum analyzer can be set to Free
Run. This is useful when the frequency domain data is continuous and
unrelated to events occurring in the time domain.
Ultra-wide capture bandwidth
Today's wireless communications vary significantly with time, using
sophisticated digital modulation schemes and, often, transmission
techniques that involve bursting the output. These modulation schemes can
have very wide bandwidth as well. Traditional swept or stepped spectrum
analyzers are ill equipped to view these types of signals as they are only
able to look at a small portion of the spectrum at any one time.
The amount of spectrum acquired in one acquisition is called the capture
bandwidth. Traditional spectrum analyzers sweep or step the capture
bandwidth through the desired span to build the requested image. As a
result, while the spectrum analyzer is acquiring one portion of the spectrum,
the event you care about may be happening in another portion of the
spectrum. Most spectrum analyzers on the market today have 10 MHz
capture bandwidths, sometimes with expensive options to extend that to
20, 40, or even 160 MHz in some cases.
In order to address the bandwidth requirements of modern RF, the
MDO4000B Series provides ≥1 GHz of capture bandwidth. At span settings
of 1 GHz and below, there is no requirement to sweep the display. The
spectrum is generated from a single acquisition, thus guaranteeing you'll
see the events you're looking for in the frequency domain.
Datasheet
10 www.tektronix.com
Spectral display of a bursted communication both into a device through Zigbee at
900 MHz and out of the device through Bluetooth at 2.4 GHz, captured with a single
acquisition.
Spectrum traces
The MDO4000B Series spectrum analyzer offers four different traces or
views including Normal, Average, Max Hold, and Min Hold. You can set the
detection method used for each trace type independently or you can leave
the oscilloscope in the default Auto mode that sets the detection type
optimally for the current configuration. Detection types include +Peak, -
Peak, Average, and Sample.
Normal, Average, Max Hold, and Min Hold spectrum traces
RF measurements
The MDO4000B Series includes three automated RF measurements -
Channel Power, Adjacent Channel Power Ratio, and Occupied Bandwidth.
When one of these RF measurements is activated, the oscilloscope
automatically turns on the Average spectrum trace and sets the detection
method to Average for optimal measurement results.
Automated Channel Power measurement
EMI Troubleshooting
EMC testing is expensive regardless of whether you purchase the
equipment to perform in-house testing or you pay an external test facility to
certify your product. And that assumes that your product passes the first
time. Multiple visits to a test house can add significant cost and delay to
your project. The key to minimizing this expense is early identification and
debug of EMI issues. Traditionally, spectrum analyzers with near field
probe sets have been used to identify the location and amplitude of
offending frequencies, but their ability to determine the cause of the issue is
very limited. Designers are increasingly using oscilloscopes and logic
analyzers as EMI issues become more transient due to the complex
interactions of numerous digital circuits in modern designs.
The MDO4000B, with its integrated oscilloscope, logic analyzer, and
spectrum analyzer is the ultimate tool for debugging modern EMI issues.
Many EMI problems are caused from events rooted in the time domain,
such as clocks, power supplies, and serial data links. With its ability to
provide time correlated views of analog, digital, and RF signals, the
MDO4000B is the only instrument available that can discover the
connection between time-domain events and offending spectral emissions.
Mixed Domain Oscilloscopes — MDO4000B Series
www.tektronix.com 11
Advanced RF analysis
When paired with SignalVu-PC and its Live Link option, the MDO4000B
Series becomes the industry's widest bandwidth Vector Signal Analyzer
with up to 1 GHz capture bandwidth. Whether your design validation needs
include Wireless LAN, wideband radar, high data rate satellite links, or
frequency-hopping communications, SignalVu-PC vector signal analysis
software can speed your time-to-insight by showing you the time-variant
behavior of these wideband signals. Available analysis options include Wi-
Fi (IEEE 802.11 a/b/g/j/n/p/ac) signal quality analysis, Bluetooth Tx
compliance, pulse analysis, audio measurements, AM/FM/PM modulation
analysis, general purpose digital modulation and more.
MDO4000B paired with SignalVu-PC to analyze 802.11ac modulation.
RF probing
Signal input methods on spectrum analyzers are typically limited to cabled
connections or antennas. But with the optional TPA-N-VPI adapter, any
active, 50 Ω TekVPI probe can be used with the spectrum analyzer on the
MDO4000B Series. This enables additional flexibility when hunting for
noise sources and enables easier spectral analysis by using true signal
browsing on an RF input.
In addition, an optional preamplifier accessory assists in the investigation of
lower-amplitude signals. The TPA-N-PRE preamplifier provides 12 dB
nominal gain across the 9 kHz - 6 GHz frequency range.
The optional TPA-N-VPI adapter enables any active, 50 Ω TekVPI probe to be
connected to the spectrum analyzer.
The TPA-N-PRE preamplifier provides 12 dB nominal gain across the 9 kHz - 6 GHz
frequency range.
Wave Inspector® navigation and search
With long record lengths, a single acquisition can include thousands of
screens of waveform data. Wave Inspector®, the industry’s best tool for
navigation and search, enables you to find events of interest in seconds.
Datasheet
12 www.tektronix.com
Wave Inspector controls provide unprecedented efficiency in viewing, navigating, and
analyzing waveform data. Zip through your long record by turning the outer pan control
(1). Get details from the beginning to end in seconds. See something of interest and want
to see more details? Just turn the inner zoom control (2).
Zoom and pan
A dedicated, two-tier front-panel control provides intuitive control of both
zooming and panning. The inner control adjusts the zoom factor (or zoom
scale); turning it clockwise activates zoom and goes to progressively higher
zoom factors, while turning it counterclockwise results in lower zoom
factors and eventually turning zoom off. No longer do you need to navigate
through multiple menus to adjust your zoom view. The outer control pans
the zoom box across the waveform to quickly get to the portion of waveform
you are interested in. The outer control also utilizes force-feedback to
determine how fast to pan on the waveform. The farther you turn the outer
control, the faster the zoom box moves. Pan direction is changed by simply
turning the control the other way.
Play/Pause
A dedicated Play/Pause front-panel button scrolls the waveform across the
display automatically while you look for anomalies or an event of interest.
Playback speed and direction are controlled using the intuitive pan control.
Once again, turning the control further makes the waveform scroll faster
and changing direction is as simple as turning the control the other way.
User marks
Press the Set Mark front-panel button to place one or more marks on the
waveform. Navigating between marks is as simple as pressing the
Previous (←) and Next (→) buttons on the front panel.
Search marks
The Search button allows you to automatically search through your long
acquisition looking for user-defined events. All occurrences of the event are
highlighted with search marks and are easily navigated to, using the front-
panel Previous (←) and Next (→) buttons. Search types include edge,
pulse width/glitch, timeout, runt, logic, setup and hold, rise/fall time, parallel
bus, and I2C, SPI, USB, Ethernet, CAN, LIN, FlexRay, RS-232/422/485/
UART, MIL-STD-1553, and I2S/LJ/RJ/TDM packet content. A search mark
table provides a tabular view of the events found during the automated
search. Each event is shown with a time stamp, making timing
measurements between events easy.
Search step 1: You define what you would like to find.
Search step 2: Wave Inspector automatically searches through the record and marks
each event with a hollow white triangle. You can then use the Previous and Next buttons
to jump from one event to the next.
Mixed Domain Oscilloscopes — MDO4000B Series
www.tektronix.com 13
Search step 3: The Search Mark table provides a tabular view of each of the events
found by the automated search. Each event is shown with a time stamp making timing
measurements between events easy.
Serial triggering and analysis (optional)
On a serial bus, a single signal often includes address, control, data, and
clock information. This can make isolating events of interest difficult.
Automatic trigger, decode, and search on bus events and conditions gives
you a robust set of tools for debugging serial buses. The optional serial
protocol triggering and analysis functionality is offered free for a 30-day trial
period. This free trial period starts automatically when the instrument is
powered on for the first time.
Triggering on a specific OUT Token packet on a USB full-speed serial bus. The yellow
waveform is the D+ and the blue waveform is the D-. A bus waveform provides decoded
packet content including Start, Sync, PID, Address, End Point, CRC, Data values, and
Stop.
Serial triggering
Trigger on packet content such as start of packet, specific addresses,
specific data content, unique identifiers, etc. on popular serial interfaces
such as I2C, SPI, USB, Ethernet, CAN, LIN, FlexRay, RS-232/422/485/
UART, MIL-STD-1553, and I2S/LJ/RJ/TDM.
Bus display
Provides a higher-level, combined view of the individual signals (clock,
data, chip enable, etc.) that make up your bus, making it easy to identify
where packets begin and end and identifying sub-packet components such
as address, data, identifier, CRC, etc.
Bus decoding
Tired of having to visually inspect the waveform to count clocks, determine
if each bit is a 1 or a 0, combine bits into bytes, and determine the hex
value? Let the oscilloscope do it for you! Once you've set up a bus, the
MSO/DPO4000B Series will decode each packet on the bus, and display
the value in hex, binary, decimal (USB, Ethernet, MIL-STD-1553, LIN, and
FlexRay only), signed decimal (I2S/LJ/RJ/TDM only), or ASCII (USB,
Ethernet, and RS-232/422/485/UART only) in the bus waveform.
Event table
In addition to seeing decoded packet data on the bus waveform itself, you
can view all captured packets in a tabular view much like you would see in
a software listing. Packets are time stamped and listed consecutively with
columns for each component (Address, Data, etc.). You can save the event
table data in .csv format.
Event table showing decoded identifier, DLC, DATA, and CRC for every CAN packet in a
long acquisition.
Datasheet
14 www.tektronix.com
Technology Trigger, Decode,
Search
Order product
Embedded I2C Yes DPO4EMBD
SPI Yes DPO4EMBD
Computer RS232/422/485,
UART
Yes DPO4COMP
USB USB LS, FS, HS Yes DPO4USB
Ethernet 10Base-T,
100Base-TX
Yes DPO4ENET
Automotive CAN Yes DPO4AUTO or
DPO4AUTOMAX
LIN Yes DPO4AUTO or
DPO4AUTOMAX
FlexRay Yes DPO4AUTOMAX
Military and
Aerospace
MIL-STD-1553 Yes DPO4AERO
Audio I2S Yes DPO4AUDIO
LJ, RJ Yes DPO4AUDIO
TDM Yes DPO4AUDIO
Search (serial triggering)
Serial triggering is very useful for isolating the event of interest, but once
you’ve captured it and need to analyze the surrounding data, what do you
do? In the past, users had to manually scroll through the waveform
counting and converting bits and looking for what caused the event. You
can have the oscilloscope automatically search through the acquired data
for user-defined criteria including serial packet content. Each occurrence is
highlighted by a search mark. Rapid navigation between marks is as simple
as pressing the Previous (←) and Next (→) buttons on the front panel.
Power analysis (optional)
Ever increasing consumer demand for longer battery-life devices and for
green solutions that consume less power require power-supply designers to
characterize and minimize switching losses to improve efficiency. In
addition, the supply’s power levels, output purity, and harmonic feedback
into the power line must be characterized to comply with national and
regional power quality standards. Historically, making these and many
other power measurements on an oscilloscope has been a long, manual,
and tedious process. The optional power analysis tools greatly simplify
these tasks, enabling quick and accurate analysis of power quality,
switching loss, harmonics, safe operating area (SOA), modulation, ripple,
and slew rate (di/dt, dv/dt). Completely integrated into the oscilloscope, the
power analysis tools provide automated, repeatable power measurements
with a touch of a button; no external PC or complex software setup is
required. The optional power analysis functionality is offered free for a 30-
day trial period. This free trial period starts automatically when the
instrument is powered on for the first time.
Safe operating area measurement. Automated power measurements enable quick and
accurate analysis of common power parameters.
Limit/Mask testing (optional)
A common task during the development process is characterizing the
behavior of certain signals in a system. One method, called limit testing, is
to compare a tested signal to a known good or "golden" version of the
same signal with user-defined vertical and horizontal tolerances. Another
common method, called mask testing, is to compare a tested signal to a
mask, looking for where a signal under test violates the mask. The
MDO4000B Series offers both limit and mask testing capability useful for
long-term signal monitoring, characterizing signals during design, or testing
on a production line. A robust set of telecommunications and computer
standards are provided to test for compliance to a standard. Additionally,
custom masks can be created and used for characterizing signals. Tailor a
test to your specific requirements by defining test duration in number of
waveforms or time, a violation threshold that must be met before
considering a test a failure, counting hits along with statistical information,
and actions upon violations, test failure, and test complete. Whether
specifying a mask from a known good signal or from a custom or standard
mask, conducting pass/fail tests in search of waveform anomalies such as
glitches has never been easier. The optional limit/mask test functionality is
offered free for a 30-day trial period. This free trial period starts
automatically when the instrument is powered on for the first time.
Mixed Domain Oscilloscopes — MDO4000B Series
www.tektronix.com 15
Limit Test showing a mask created from a golden waveform and compared against a live
signal. Results showing statistical information about the test are displayed.
Video design and development
Many video engineers have remained loyal to analog oscilloscopes,
believing the intensity gradations on an analog display are the only way to
see certain video waveform details. The fast waveform capture rate,
coupled with its intensity-graded view of the signal, provides the same
information-rich display as an analog oscilloscope, but with much more
detail and all the benefits of digital scopes.
Standard features such as IRE and mV graticules, holdoff by fields, video
polarity, and an Autoset smart enough to detect video signals, make these
the easiest to use oscilloscopes on the market for video applications. And
with high bandwidth and four analog inputs, the oscilloscope provides
ample performance for analog and digital video use.
The video functionality is further extended with an optional video application
module, which provides the industry's most complete suite of HDTV and
custom (nonstandard) video triggers, as well as a video picture mode
enabling you to see the picture of the video signal you are viewing - for
NTSC and PAL signals. The optional video analysis functionality is offered
free for a 30- day trial period. This free trial period starts automatically when
the instrument is powered on for the first time.
Viewing an NTSC video image. Video picture mode contains automatic contrast and
brightness settings as well as manual controls.
Designed to make your work easier
The MDO4000B Series is designed to make your work easier. The large, high-resolution
display shows intricate signal details. Dedicated front-panel controls simplify operation.
Two USB host ports on the front panel allow you to easily transfer screen shots,
instrument settings, and waveform data to a USB mass storage device.
Large, high-resolution display
The MDO4000B Series features a 10.4 in. (264 mm) bright, LED backlit
XGA color display for seeing intricate signal details.
Datasheet
16 www.tektronix.com
Connectivity
The MDO4000B contains a number of ports which can be used to connect
the instrument to a network, directly to a PC, or other test equipment.
Two USB host ports on the front and two USB host ports on the rear
enable easy transfer of screen shots, instrument settings, and
waveform data to a USB mass storage device. A USB keyboard can
also be attached to a USB host port for data entry.
Rear USB device port is useful for controlling the oscilloscope remotely
from a PC or for printing directly to a PictBridge®-compatible printer.
The standard 10/100/1000BASE-T Ethernet port on the rear of the
instrument enables easy connection to networks, provides network and
e-mail printing, and provides LXI Class-C compatibility. The instrument
can also mount network drives for easy storage of screen images,
setup files, or data files.
A video out port on the rear of the instrument allows the display to be
exported to an external monitor or projector.
Compact form factor
With the compact, portable form factor, you can easily move the
oscilloscope between labs. And with a depth of just 5.8 inches (147 mm), it
saves you valuable space on your test bench.
TekVPI® probe interface
The TekVPI probe interface sets the standard for ease of use in probing. In
addition to the secure, reliable connection that the interface provides,
TekVPI probes feature status indicators and controls, as well as a probe
menu button right on the comp box itself. This button brings up a probe
menu on the oscilloscope display with all relevant settings and controls for
the probe. The TekVPI interface enables direct attachment of current
probes without requiring a separate power supply. TekVPI probes can be
controlled remotely through USB, GPIB, or LAN, enabling more versatile
solutions in ATE environments. The instrument provides up to 50 W of
power to the front panel TekVPI connectors from the internal power supply,
giving you the confidence that it can meet any demanding probing
requirements you have.
TekVPI probe interface simplifies connecting your probes to the oscilloscope.
Remote connectivity and instrument control
Exporting data and measurements is as simple as connecting a USB cable
from the oscilloscope to your PC. Key software applications –
OpenChoice® Desktop, and Microsoft Excel and Word toolbars – are
included standard with each oscilloscope to enable fast and easy direct
communication with your Windows PC.
The included OpenChoice Desktop enables fast and easy communication
between the oscilloscope and your PC through USB or LAN for transferring
settings, waveforms, and screen images.
OpenChoice Desktop software enables seamless connection between the oscilloscope
and your PC.
The embedded e*Scope® capability enables fast control of the oscilloscope
over a network connection through a standard web browser. Simply enter
the IP address or network name of the oscilloscope and a web page will be
served to the browser. Transfer and save settings, waveforms,
measurements, and screen images or make live control changes to settings
on the oscilloscope directly from the web browser.
The MDO4000B Series can also be connected to your network using the
LAN port. The included LXI web interface provides information about the
current configuration of your MDO4000B Series oscilloscope, including
network configuration. You can make changes to the network configuration,
control instrument settings, save screen images and instrument data, and
save/load instrument setups of your oscilloscope directly from the web
interface through a password-protected web page.
Mixed Domain Oscilloscopes — MDO4000B Series
www.tektronix.com 17
Specifications
All specifications apply to all models unless noted otherwise.
Model overview
MDO4014B-3 MDO4034B-3 MDO4054B-3 MDO4054B-6 MDO4104B-3 MDO4104B-6
Analog channels 4 4 4 4 4 4
Analog channel bandwidth 100 MHz 350 MHz 500 MHz 500 MHz 1 GHz 1 GHz
Rise time 3.5 ns 1 ns 700 ps 700 ps 350 ps 350 ps
Sample rate (1 ch) 2.5 GS/s 2.5 GS/s 2.5 GS/s 2.5 GS/s 5 GS/s 5 GS/s
Sample rate (2 ch) 2.5 GS/s 2.5 GS/s 2.5 GS/s 2.5 GS/s 5 GS/s 5 GS/s
Sample rate (4 ch) 2.5 GS/s 2.5 GS/s 2.5 GS/s 2.5 GS/s 2.5 GS/s 2.5 GS/s
Record length (1 ch) 20M 20M 20M 20M 20M 20M
Record length (2 ch) 20M 20M 20M 20M 20M 20M
Record length (4 ch) 20M 20M 20M 20M 20M 20M
Digital channels 16 16 16 16 16 16
Spectrum analyzer channels 1 1 1 1 1 1
Spectrum analyzer frequency range 9 kHz - 3 GHz 9 kHz - 3 GHz 9 kHz - 3 GHz 9 kHz - 6 GHz 9 kHz - 3 GHz 9 kHz - 6 GHz
Vertical system analog channels
Hardware bandwidth limits
≥350 MHz models 20 MHz or 250 MHz
100 MHz models 20 MHz
Input coupling AC, DC
Input impedance 1 MΩ ±1%, 50 Ω ±1%
Input sensitivity range
1 MΩ 1 mV/div to 10 V/div
50 Ω 1 mV/div to 1 V/div
Vertical resolution 8 bits (11 bits with Hi Res)
Maximum input voltage
1 MΩ 300 VRMS CAT II with peaks ≤ ±425 V
50 Ω 5 VRMS with peaks ≤ ±20 V (DF ≤ 6.25%)
DC gain accuracy ±1.5%, derated at 0.10%/°C above 30 °C
Channel-to-channel isolation Any two channels at equal vertical scale ≥100:1 at ≤100 MHz and ≥30:1 at >100 MHz up to the rated bandwidth
Datasheet
18 www.tektronix.com
Offset range Volts/div setting Offset range
1 MΩ input 50 Ω
1 mV/div to 50 mV/div ±1 V ±1 V
50.5 mV/div to 99.5 mV/div ±0.5 V ±0.5 V
100 mV/div to 500 mV/div ±10 V ±10 V
505 mV/div to 995 mV/div ±5 V ±5 V
1 V/div to 5 V/div ±100 V ±5 V
5.05 V/div to 10 V/div ±50 V NA
Vertical system digital channels
Input channels 16 digital (D15 to D0)
Thresholds Per-channel thresholds
Threshold selections TTL, CMOS, ECL, PECL, User-defined
User-defined threshold range ±40 V
Threshold accuracy ±[100 mV + 3% of threshold setting]
Maximum input voltage ±42 Vpeak
Input dynamic range 30 Vp-p ≤200 MHz
10 Vp-p >200 MHz
Minimum voltage swing 400 mV
Probe loading 100 kΩ in parallel with 3 pF
Vertical resolution 1 bit
Horizontal system analog channels
Time base range
1 GHz models 400 ps to 1000 s
≤ 500 MHz models 1 ns to 1000 s
Maximum duration at highest
sample rate (all/half channels)
1 GHz models 8/4 ms
≤ 500 MHz models 8/8 ms
Time-base delay time range -10 divisions to 5000 s
Channel-to-channel deskew range ±125 ns
Time base accuracy ±5 ppm over any ≥1 ms interval
Mixed Domain Oscilloscopes — MDO4000B Series
Vertical system analog channels
www.tektronix.com 19
Horizontal system digital channels
Maximum sample rate (Main) 500 MS/s (2 ns resolution)
Maximum record length (Main) 20M points
Maximum sample rate (MagniVu) 16.5 GS/s (60.6 ps resolution)
Maximum record length (MagniVu) 10k points centered around the trigger
Minimum detectable pulse width
(typical)
1 ns
Channel-to-channel skew (typical) 200 ps
Maximum input toggle rate 500 MHz (Maximum frequency sine wave that can accurately be reproduced as a logic square wave. Requires the use of a short
ground extender on each channel. This is the maximum frequency at the minimum swing amplitude. Higher toggle rates can be
achieved with higher amplitudes.)
Spectrum analyzer input
Span 1 kHz - 3 GHz (MDO4XX4B-3 models) or 1 kHz - 6 GHz (MDO4XX4B-6 models)
Span adjustable in a 1-2-5 sequence
Variable resolution = 1% of the next span setting
Resolution bandwidth range The resolution bandwidth range for windowing functions is as follows:
Kaiser (default): 20 Hz - 200 MHz
Rectangular: 10 Hz - 200 MHz
Hamming: 10 Hz - 200 MHz
Hanning: 10 Hz - 200 MHz
Blackman-Harris: 20 Hz - 200 MHz
Flat-top: 30 Hz - 200 MHz
Adjusted in a 1-2-3-5 sequence
RBW shape factor (Kaiser) 60 dB / 3 dB shape factor: ≥ 4:1
Reference level Setting range: -140 dBm to +30 dBm in steps of 1 dB
Input vertical range Vertical measurement range: +30 dBm to DANL
Vertical setting of 1 dB/div to 20 dB/div in a 1-2-5 sequence
Vertical position -100 divs to +100 divs
Vertical units dBm, dBmV, dBµV, dBµW, dBmA, dBµA
Datasheet
20 www.tektronix.com
Displayed average noise level
(DANL)
Frequency range DANL
9 kHz - 50 kHz < -116 dBm/Hz (< -120 dBm/Hz, typical)
50 kHz - 5 MHz < -130 dBm/Hz (< -134 dBm/Hz, typical)
5 MHz - 400 MHz < -146 dBm/Hz (< -148 dBm/Hz, typical)
400 MHz - 3 GHz < -147 dBm/Hz (< -149 dBm/Hz, typical)
3 GHz - 4 GHz (MDO4XX4B-6 models only) < -148 dBm/Hz (< -152 dBm/Hz, typical)
4 GHz - 6 GHz (MDO4XX4B-6 models only) < -140 dBm/Hz (< -144 dBm/Hz, typical)
DANL with TPA-N-PRE preamp
attached
Preamp set to "Auto", and Reference Level set to -40 dBm.
The DANL of the MDO4000B with the preamp in the Bypass state is ≤3 dB higher than the DANL of the MDO4000B without the
preamp.
Frequency range DANL
9 kHz - 50 kHz < -119 dBm/Hz (< -123 dBm/Hz, typical)
50 kHz - 5 MHz < -140 dBm/Hz (< -144 dBm/Hz, typical)
5 MHz - 400 MHz < -156 dBm/Hz (< -158 dBm/Hz, typical)
400 MHz - 3 GHz < -157 dBm/Hz (< -159 dBm/Hz, typical)
3 GHz - 4 GHz (MDO4XXB-6 models only) < -158 dBm/Hz (< -162 dBm/Hz, typical)
4 GHz - 6 GHz (MDO4XXB-6 models only) < -150 dBm/Hz (< -154 dBm/Hz, typical)
Spurious response
2nd and 3rd harmonic
distortion (>100 MHz)
< -60 dBc (< -65 dBc, typical), with auto settings on and signals 10 dB below reference level
2nd and 3rd harmonic
distortion (9 kHz to 100 MHz)
< -60 dBc (< -65 dBc, typical), with auto settings on, signals 10 dB below reference level, and reference level ≤ -15 dBm
2nd order intermodulation
distortion (>100 MHz)
< -60 dBc (< -65 dBc, typical), with auto settings on and signals 10 dB below reference level
2nd order intermodulation
distortion (9 kHz to 100 MHz)
< -60 dBc (< -65 dBc, typical), with auto settings on, signals 10 dB below reference level, and reference level ≤ -15 dBm
3rd order intermodulation
distortion: > 15 MHz
< -62 dBc, (<-65 dBc, typical), with auto settings on and signals 10 dB below reference level
3rd order intermodulation
distortion: 9 kHz to 15 MHz
< -62 dBc (<-65 dBc, typical), with auto settings on and signals 10 dB below reference level, and reference levels < -15 dBm
A/D spurs < -60 dBc (< -65 dBc, typical), with auto settings on and signals 5 dB below reference level. Excludes A/D aliasing spurs
A/D aliasing spurs At (5 GHz - Fin) and (8 GHz - Fin): <-55 dBc (<-60 dBc, typical), with auto settings on and signals 5 dB below reference level
Specifications that only apply
to MDO4XX4-6 models
IF Rejection: (All Input Frequencies except: 1.00 GHz to 1.25 GHz and 2 GHz to 2.4 GHz): < -55 dBc, typical
IF spurs at (5 GHz - Fin) for input frequencies from 1.00 GHz to 1.25 GHz: < -50 dBc, typical
IF spurs at (6.5 GHz -Fin) for input frequencies from 2 GHz to 2.4 GHz: < -50 dBc, typical
Image Rejection: < -50 dBc (for input frequencies from 5.5 GHz to 9.5 GHz)
Residual response < -85 dBm (< -78 dBm at 2.5 GHz, 3.75 GHz, 4.0 GHz, and 5.0 GHz) with ≤ -25 dBm reference level and input terminated with
50 Ω
Mixed Domain Oscilloscopes — MDO4000B Series
Spectrum analyzer input
www.tektronix.com 21
Absolute amplitude accuracy Accuracy of power level measurements at the center frequency. At frequencies away from center frequency, add Channel
Response to the Absolute Amplitude Accuracy. Applies to signal to noise ratios > 40 dB.
< ± 1.0 dB (< ±0.5 dB, typical), 18 °C - 28 °C temperature range, 50 kHz to 6 GHz frequency range, reference levels -25, -20, -15,
-10, -5, 0, 5, 10 dBm
< ± 1.0 dB, typical, 50 kHz to 6 GHz, all other reference levels, 18 °C - 28 °C temperature range
< ±1.5 dB, typical, 50 kHz to 6 GHz, all reference levels, 0 C to 50 C temperature range
< ± 2.0 dB, typical, 9 kHz to 50 kHz, all reference levels, 18 °C to 28 °C temperature range
< ± 3.0 dB, typical, 9 kHz to 50 kHz, all reference levels, 0 °C to 50 °C temperature range
Channel response, typical Valid over 18 - 28 °C temperature range
Specification applies to signal-to-noise ratios > 40 dB
Measurement center
frequency range
Span Amplitude flatness,
pk-pk, typical
Amplitude flatness,
RMS, typical
Phase linearity, RMS,
typical
15 MHz - 6 GHz 10 MHz 0.3 dB 0.15 dB 1.5 °
60 MHz - 6 GHz ≤ 100 MHz 0.75 dB 0.27 dB 1.5 °
170 MHz - 6 GHz ≤ 320 MHz 0.85 dB 0.27 dB 2.5 °
510 MHz - 6 GHz ≤ 1,000 MHz 1.0 dB 0.3 dB 3.0 °
Any, (for start frequency
> 10 MHz)
> 1,000 MHz 1.2 dB N/A N/A
Absolute amplitude accuracy
(AAA) and channel response (CR),
with TPA-N-PRE preamp attached
AAA: ≤ ±1.5 dB (typical), 18 C - 28 C temperature range, either preamp state.
AAA: ≤ ±2.3 dB (typical), over full operating range, either preamp state.
CR: 0.0 dB
Crosstalk to spectrum analyzer
from oscilloscope channels
≤1 GHz input frequencies < -68 dB from reference level
>1 GHz - 2 GHz input
frequencies
< -48 dB from reference level
Phase noise at 1 GHz CW
1 kHz < -104 dBc/Hz (typical)
10 kHz < -108 dBc/Hz, < -111 dBc/Hz (typical)
100 kHz < -110 dBc/Hz, < -113 dBc/Hz (typical)
1 MHz < -120 dBc/Hz, < -123 dBc/Hz (typical)
Reference frequency error
(cumulative)
Cumulative error: 1.6 x 10-6
Includes allowances for aging per year, reference frequency calibration accuracy, and temperature stability
Valid over the recommended one-year calibration interval, from 0 °C to +50 °C
Marker frequency measurement
accuracy
±((1.6 x 10-6 x Marker-Frequency) + (0.001 x span + 2)) Hz
Example: assuming the span is set to 10 kHz and the marker is at 1500 MHz, this would result in a Frequency Measurement
Accuracy of +/-((1.6 x 10-6 x 1500 MHz) + (0.001 x 10 kHz + 2)) = +/- 2.412 kHz.
Marker Frequency with Span/RBW ≤ 1000:1
Reference Frequency Error with Marker level to displayed noise level > 30 dB
Frequency measurement
resolution
1 Hz
Datasheet
Spectrum analyzer input
22 www.tektronix.com
Maximum operating input level
Average continuous power +30 dBm (1 W) for reference levels ≥ -20 dBm
+24 dBm (0.25 W) for reference levels < -20 dBm
DC maximum before damage ±40 VDC
Maximum power before
damage (CW)
+32 dBm (1.6 W) for reference levels ≥ -20 dBm
+25 dBm (0.32 W) for reference levels of < -20 dBm
Maximum power before
damage (pulse)
Peak Pulse Power: +45 dBm (32 W)
Peak Pulse Power defined as <10 μs pulse width, <1% duty cycle, and reference level of ≥ +10 dBm
Maximum operating input level
with TPA-N-PRE preamp attached
Average continuous power +30 dBm (1 W)
DC maximum before damage ±20 VDC
Maximum power before
damage (CW)
+30 dBm (1 W)
Maximum power before
damage (pulse)
+45 dBm (32 W) (<10 μs pulse width, <1% duty cycle, and reference level of ≥ +10 dBm)
RF power level trigger
Frequency range MDO4XX4B-3: 1 MHz to 3 GHz
MDO4XX4B-6: 1 MHz to 3.75 GHz; 2.75 GHz to 4.5 GHz, 3.5 GHz to 6.0 GHz
Amplitude operating level 0 dB to -30 dB from Reference Level
Amplitude range +10 dB to -40 dB from Reference Level and within the range of -65 dBm to +30 dBm
Minimum pulse duration 10 µs On Time with a minimum settling Off Time of 10 µs
Spectrum analyzer to analog
channel skew
<5 ns
RF acquisition length Span Maximum RF acquisition time
>2 GHz 5 ms
>1 GHz - 2 GHz 10 ms
>800 MHz - 1 GHz 20 ms
>500 MHz - 800 MHz 25 ms
>400 MHz - 500 MHz 40 ms
>250 MHz - 400 MHz 50 ms
>200 MHz - 250 MHz 80 ms
>160 MHz - 200 MHz 100 ms
>125 MHz - 160 MHz 125 ms
<125 MHz 158 ms
FFT window types, factors and
RBW accuracy
FFT window Factor RBW Accuracy
Kaiser 2.23 0.90%
Rectangular 0.89 2.25%
Hamming 1.30 1.54%
Hanning 1.44 1.39%
Blackman-Harris 1.90 1.05%
Flat-Top 3.77 0.53%
Mixed Domain Oscilloscopes — MDO4000B Series
Spectrum analyzer input
www.tektronix.com 23
Trigger system
Trigger modes Auto, Normal, and Single
Trigger coupling DC, AC, HF reject (attenuates >50 kHz), LF reject (attenuates <50 kHz), noise reject (reduces sensitivity)
Trigger holdoff range 20 ns to 8 s
Trigger sensitivity
Internal DC coupled Trigger source Sensitivity
1 MΩ path (all models) For 1 mV/div to 4.98 mV/div; 0.75 div from DC to 50 MHz,
increasing to 1.3 div at rated bandwidth
50 Ω path (≤500 MHz models) For ≥5 mV/div; 0.4 div from DC to 50 MHz, increasing to 1 div
at rated bandwidth
50 Ω path (1 GHz models) 0.4 div from DC to 50 MHz, increasing to 1 div at rated
bandwidth
Trigger level ranges
Any input channel ±8 divisions from center of screen, ±8 divisions from 0 V when vertical LF reject trigger coupling is selected
Line The line trigger level is fixed at about 50% of the line voltage.
Trigger frequency readout Provides 6-digit frequency readout of triggerable events.
Trigger types
Edge Positive, negative, or either slope on any channel. Coupling includes DC, AC, HF reject, LF reject, and noise reject.
Sequence (B-trigger) Trigger Delay by Time: 4 ns to 8 s. Or Trigger Delay by Events: 1 to 4,000,000 events.
Pulse Width Trigger on width of positive or negative pulses that are >, <, =, ≠, or inside/outside a specified period of time.
Timeout Trigger on an event which remains high, low, or either, for a specified time period (4 ns to 8 s).
Runt Trigger on a pulse that crosses one threshold but fails to cross a second threshold before crossing the first again.
Logic Trigger when any logical pattern of channels goes false or stays true for specified period of time. Any input can be used as a clock
to look for the pattern on a clock edge. Pattern (AND, OR, NAND, NOR) specified for all input channels defined as High, Low, or
Don’t Care.
Setup and Hold Trigger on violations of both setup time and hold time between clock and data present on any of the analog and digital input
channels.
Rise/Fall Time Trigger on pulse edge rates that are faster or slower than specified. Slope may be positive, negative, or either.
Video Trigger on all lines, odd, even, or all fields on NTSC, PAL, and SECAM video signals.
Extended Video (optional) Trigger on 480p/60, 576p/50, 720p/30, 720p/50, 720p/60, 875i/60, 1080i/50, 1080i/60, 1080p/24, 1080p/24sF, 1080p/25, 1080p/
30, 1080p/50, 1080p/60, and custom bi-level and tri-level sync video standards.
I2C (optional) Trigger on Start, Repeated Start, Stop, Missing ACK, Address (7 or 10 bit), Data, or Address and Data on I2C buses up to 10 Mb/s.
SPI (optional) Trigger on SS active, Start of Frame, MOSI, MISO, or MOSI and MISO on SPI buses up to 50.0 Mb/s.
RS-232/422/485/UART
(optional)
Trigger on Tx Start Bit, Rx Start Bit, Tx End of Packet, Rx End of Packet, Tx Data, Rx Data, Tx Parity Error, and Rx Parity Error up
to 10 Mb/s.
USB: Low speed (optional) Trigger on Sync Active, Start of Frame, Reset, Suspend, Resume, End of Packet, Token (Address) Packet, Data Packet,
Handshake Packet, Special Packet, Error.
Token packet trigger - Any token type, SOF, OUT, IN, SETUP; Address can be specified for Any Token, OUT, IN, and SETUP
token types. Address can be further specified to trigger on ≤, <, =, >, ≥, ≠ a particular value, or inside or outside of a range. Frame
number can be specified for SOF token using binary, hex, unsigned decimal and don't care digits.
Data packet trigger - Any data type, DATA0, DATA1; Data can be further specified to trigger on ≤, <, =, >, ≥, ≠ a particular data
value, or inside or outside of a range.
Handshake packet trigger - Any handshake type, ACK, NAK, STALL.
Special packet trigger - Any special type, Reserved
Error trigger - PID Check, CRC5 or CRC16, Bit Stuffing.
Datasheet
24 www.tektronix.com
USB: Full speed (optional) Trigger on Sync, Reset, Suspend, Resume, End of Packet, Token (Address) Packet, Data Packet, Handshake Packet, Special
Packet, Error.
Token packet trigger - Any token type, SOF, OUT, IN, SETUP; Address can be specified for Any Token, OUT, IN, and SETUP
token types. Address can be further specified to trigger on ≤, <, =, >, ≥, ≠ a particular value, or inside or outside of a range. Frame
number can be specified for SOF token using binary, hex, unsigned decimal and don't care digits.
Data packet trigger - Any data type, DATA0, DATA1; Data can be further specified to trigger on ≤, <, =, >, ≥, ≠ a particular data
value, or inside or outside of a range.
Handshake packet trigger - Any handshake type, ACK, NAK, STALL.
Special packet trigger - Any special type, PRE, Reserved.
Error trigger - PID Check, CRC5 or CRC16, Bit Stuffing.
USB: High speed (optional) 1 Trigger on Sync, Reset, Suspend, Resume, End of Packet, Token (Address) Packet, Data Packet, Handshake Packet, Special
Packet, Error.
Token packet trigger - Any token type, SOF, OUT, IN, SETUP; Address can be specified for Any Token, OUT, IN, and SETUP
token types. Address can be further specified to trigger on ≤, <, =, >, ≥, ≠ a particular value, or inside or outside of a range. Frame
number can be specified for SOF token using binary, hex, unsigned decimal and don't care digits.
Data packet trigger - Any data type, DATA0, DATA1, DATA2, MDATA; Data can be further specified to trigger on ≤, <, =, >, ≥, ≠ a
particular data value, or inside or outside of a range.
Handshake packet trigger - Any handshake type, ACK, NAK, STALL, NYET.
Special packet trigger - Any special type, ERR, SPLIT, PING, Reserved. SPLIT packet components that can be specified include:
▪ Hub Address
▪ Start/Complete - Don't Care, Start (SSPLIT), Complete (CSPLIT)
▪ Port Address
▪ Start and End bits - Don't Care, Control/Bulk/Interrupt (Full-speed Device, Low-speed Device), Isochronous (Data is Middle, Data
is End, Data is Start, Data is All)
▪ Endpoint Type - Don't Care, Control, Isochronous, Bulk, Interrupt
Error trigger - PID Check, CRC5 or CRC16.
Ethernet (optional) 2 10BASE-T and 100BASE-TX: Trigger on Start Frame Delimiter, MAC Addresses, MAC Q-Tag Control Information, MAC Length/
Type, IP Header, TCP Header, TCP/IPv4/MAC Client Data, End of Packet, and FCS (CRC) Error.
100BASE-TX: Idle.
MAC Addresses - Trigger on Source and Destination 48-bit address values.
MAC Q-Tag Control Information - Trigger on Q-Tag 32-bit value.
MAC Length/Type - Trigger on ≤, <, =, >, ≥, ≠ a particular 16-bit value, or inside or outside of a range.
IP Header - Trigger on IP Protocol 8-bit value, Source Address, Destination Address.
TCP Header - Trigger on Source Port, Destination Port, Sequence Number, and Ack Number.
TCP/IPv4/MAC Client Data - Trigger on ≤, <, =, >, ≥, ≠ a particular data value, or inside or outside of a range. Selectable number
of bytes to trigger on from 1-16. Byte offset options of Don't Care, 0-1499.
CAN (optional) Trigger on Start of Frame, Frame Type (data, remote, error, overload), Identifier (standard or extended), Data, Identifier and Data,
End of Frame, Missing ACK, or Bit Stuffing Error on CAN signals up to 1 Mb/s. Data can be further specified to trigger on ≤, <, =,
>, ≥, or ≠ a specific data value. User-adjustable sample point is set to 50% by default.
LIN (optional) Trigger on Sync, Identifier, Data, Identifier and Data, Wakeup Frame, Sleep Frame, Errors such as Sync, Parity, or Checksum
Errors up to 100 kb/s (by LIN definition, 20 kb/s).
FlexRay (optional) Trigger on Start of Frame, Type of Frame (Normal, Payload, Null, Sync, Startup), Identifier, Cycle Count, Complete Header Field,
Data, Identifier and Data, End of Frame or Errors such as Header CRC, Trailer CRC, Null Frame, Sync Frame, or Startup Frame
Errors up to 100 Mb/s.
1High-speed support only available on models with 1 GHz analog channel bandwidth.
2≥350 MHz bandwidth models are recommended for 100BASE-TX
Mixed Domain Oscilloscopes — MDO4000B Series
Trigger system
www.tektronix.com 25
MIL-STD-1553 (optional) Trigger on Sync, Word Type 3 (Command, Status, Data), Command Word (set RT Address, T/R, Sub-address/Mode, Data Word
Count/Mode Code, and Parity individually), Status Word (set RT Address, Message Error, Instrumentation, Service Request Bit,
Broadcast Command Received, Busy, Subsystem Flag, Dynamic Bus Control Acceptance (DBCA), Terminal Flag, and Parity
individually), Data Word (user-specified 16-bit data value), Error (Sync, Parity, Manchester, Non-contiguous data), Idle Time
(minimum time selectable from 2 µs to 100 µs; maximum time selectable from 2 µs to 100 µs; trigger on < minimum, > maximum,
inside range, outside range). RT Address can be further specified to trigger on =, ≠, <, >, ≤, ≥ a particular value, or inside or
outside of a range.
I2S/LJ/RJ/TDM (optional) Trigger on Word Select, Frame Sync, or Data. Data can be further specified to trigger on ≤, <, =, >, ≥, ≠ a specific data value, or
inside or outside of a range. Maximum data rate for I2S/LJ/RJ is 12.5 Mb/s. Maximum data rate for TDM is 25 Mb/s.
Parallel Trigger on a parallel bus data value. Parallel bus can be from 1 to 20 bits (from the digital and analog channels) in size. Binary and
Hex radices are supported.
Acquisition system
Acquisition Modes
Sample Acquire sampled values.
Peak Detect Captures glitches as narrow as 800 ps (1 GHz models) or 1.6 ns (≤500 MHz models) at all sweep speeds
Averaging From 2 to 512 waveforms included in average.
Envelope Min-max envelope reflecting Peak Detect data over multiple acquisitions.
Hi Res Real-time boxcar averaging reduces random noise and increases vertical resolution.
Roll Scrolls waveforms right to left across the screen at sweep speeds slower than or equal to 40 ms/div.
FastAcqFastAcq optimizes the instrument for analysis of dynamic signals and capture of infrequent events, capturing >340,000 wfms/s on
1 GHz models and >270,000 wfms/s on 100 MHz - 500 MHz models.
Waveform measurements
Cursors Waveform and Screen.
Automatic measurements
(time domain)
30, of which up to eight can be displayed on-screen at any one time. Measurements include: Period, Frequency, Delay, Rise Time,
Fall Time, Positive Duty Cycle, Negative Duty Cycle, Positive Pulse Width, Negative Pulse Width, Burst Width, Phase, Positive
Overshoot, Negative Overshoot, Total Overshoot, Peak to Peak, Amplitude, High, Low, Max, Min, Mean, Cycle Mean, RMS, Cycle
RMS, Positive Pulse Count, Negative Pulse Count, Rising Edge Count, Falling Edge Count, Area and Cycle Area.
Automatic measurements
(frequency domain)
3, of which one can be displayed on-screen at any one time. Measurements include Channel Power, Adjacent Channel Power
Ratio (ACPR), and Occupied Bandwidth (OBW)
Measurement statistics Mean, Min, Max, Standard Deviation.
Reference levels User-definable reference levels for automatic measurements can be specified in either percent or units.
Gating Isolate the specific occurrence within an acquisition to take measurements on, using either the screen, or waveform cursors.
Waveform histogram A waveform histogram provides an array of data values representing the total number of hits inside of a user-defined region of the
display. A waveform histogram is both a visual graph of the hit distribution as well as a numeric array of values that can be
measured.
Sources - Channel 1, Channel 2, Channel 3, Channel 4, Ref 1, Ref 2, Ref 3, Ref 4, Math
Types - Vertical, Horizontal
Waveform histogram
measurements
Waveform Count, Hits in Box, Peak Hits, Median, Max, Min, Peak-to-Peak, Mean, Standard Deviation, Sigma 1, Sigma 2, Sigma 3
3Trigger selection of Command Word will trigger on Command and ambiguous Command/Status words. Trigger selection of Status Word will trigger on Status and ambiguous Command/Status words.
Datasheet
Trigger system
26 www.tektronix.com
Waveform math
Arithmetic Add, subtract, multiply, and divide waveforms.
Math functions Integrate, Differentiate, FFT.
FFT Spectral magnitude. Set FFT Vertical Scale to Linear RMS or dBV RMS, and FFT Window to Rectangular, Hamming, Hanning, or
Blackman-Harris.
Spectrum math Add or subtract frequency-domain traces.
Advanced math Define extensive algebraic expressions including waveforms, reference waveforms, math functions (FFT, Intg, Diff, Log, Exp, Sqrt,
Abs, Sine, Cosine, Tangent, Rad, Deg), scalars, up to two user-adjustable variables and results of parametric measurements
(Period, Freq, Delay, Rise, Fall, PosWidth, NegWidth, BurstWidth, Phase, PosDutyCycle, NegDutyCycle, PosOverShoot,
NegOverShoot, PeakPeak, Amplitude, RMS, CycleRMS, High, Low, Max, Min, Mean, CycleMean, Area, CycleArea, and trend
plots), e.g.,(Intg(Ch1 - Mean(Ch1)) × 1.414 × VAR1).
Act on Event
Events None, when a trigger occurs, or when a defined number of acquisitions complete (1 to 1,000,000)
Actions Stop acquisition, save waveform to file, save screen image, print, AUX OUT Pulse, remote interface SRQ, e-mail notification, and
visual notification.
Repeat Repeat the act on event process (1 to 1,000,000 and infinity)
Video Picture Mode (optional)
Sources Channel 1, Channel 2, Channel 3, Channel 4
Video standards NTSC, PAL
Contrast and brightness Manual and automatic
Field selection Odd, Even, Interlaced
Picture location on screen Selectable X and Y location, width and height adjustment, start line and pixel and line-to-line offset control.
Power measurements (optional)
Power Quality Measurements VRMS, VCrest Factor, Frequency, IRMS, ICrest Factor, True Power, Apparent Power, Reactive Power, Power Factor, Phase Angle.
Switching loss measurements
Power loss Ton, Toff, Conduction, Total.
Energy loss Ton, Toff, Conduction, Total.
Harmonics THD-F, THD-R, RMS measurements. Graphical and table displays of harmonics. Test to IEC61000-3-2 Class A and MIL-
STD-1399, Section 300A.
Ripple measurements VRipple and IRipple.
Modulation Analysis Graphical display of +Pulse Width, –Pulse Width, Period, Frequency, +Duty Cycle, and –Duty Cycle modulation types.
Safe operating area Graphical display and mask testing of switching device safe operating area measurements.
dV/dt and dI/dt measurements Cursor measurements of slew rate.
Mixed Domain Oscilloscopes — MDO4000B Series
www.tektronix.com 27
Limit/Mask testing (optional)
Included standard masks 4 ITU-T, ANSI T1.102, USB
Test source Limit test: Any Ch1 - Ch4 or any R1 - R4
Mask test: Any Ch1 - Ch4
Mask creation Limit test vertical tolerance from 0 to 1 division in 1 m division increments; Limit test horizontal tolerance from 0 to 500 m division in
1 m division increments
Load standard mask from internal memory
Load custom mask from text file with up to 8 segments
Mask scaling Lock to Source ON (mask automatically re-scales with source-channel settings changes)
Lock to Source OFF (mask does not re-scale with source-channel settings changes)
Test criteria run until Minimum number of waveforms (from 1 to 1,000,000; Infinity)
Minimum elapsed time (from 1 second to 48 hours; Infinity)
Violation threshold From 1 to 1,000,000
Actions on test failure Stop acquisition, save screen image to file, save waveform to file, print screen image, trigger out pulse, set remote interface SRQ
Actions on test complete Trigger out pulse, set remote interface SRQ
Results display Test status, total waveforms, number of violations, violation rate, total tests, failed tests, test failure rate, elapsed time, total hits for
each mask segment
Software
OpenChoice® Desktop Enables fast and easy communication between a Windows PC and your oscilloscope using USB or LAN. Transfer and save
settings, waveforms, measurements, and screen images. Included Word and Excel toolbars automate the transfer of acquisition
data and screen images from the oscilloscope into Word and Excel for quick reporting or further analysis.
IVI driver Provides a standard instrument programming interface for common applications such as LabVIEW, LabWindows/CVI,
Microsoft .NET, and MATLAB.
e*Scope® Web-based remote
control
Enables control of the oscilloscope over a network connection through a standard web browser. Simply enter the IP address or
network name of the oscilloscope and a web page will be served to the browser. Transfer and save settings, waveforms,
measurements, and screen images or make live control changes to settings on the oscilloscope directly from the web browser.
LXI Class C Web interface Connect to the oscilloscope through a standard Web browser by simply entering the oscilloscope's IP address or network name in
the address bar of the browser. The Web interface enables viewing of instrument status and configuration, status and modification
of network settings, and instrument control through the e*Scope Web-based remote control. All Web interaction conforms to LXI
Class C specification, version 1.3.
4≥350 MHz bandwidth models are recommended for mask testing on telecomm standards >55 Mb/s. 1 GHz bandwidth models are recommended for mask testing on high-speed (HS) USB.
Datasheet
28 www.tektronix.com
Display system
Display type 10.4 in. (264 mm) liquid-crystal TFT color display
Display resolution 1,024 horizontal × 768 vertical pixels (XGA)
Interpolation Sin(x)/x
Waveform styles Vectors, Dots, Variable Persistence, Infinite Persistence.
Graticules Full, Grid, Cross Hair, Frame, IRE and mV.
Format YT and simultaneous XY/YT
Maximum waveform capture rate >340,000 wfms/s in FastAcq acquisition mode on 1 GHz models
>270,000 wfms/s in FastAcq acquisition mode on 100 MHz - 500 MHz models
>50,000 wfms/s in DPO acquisition mode on all models.
Input/output ports
USB 2.0 high-speed host port Supports USB mass storage devices and keyboard. Two ports on front and two ports on rear of instrument.
USB 2.0 device port Rear-panel connector allows for communication/control of oscilloscope through USBTMC or GPIB (with a TEK-USB-488), and
direct printing to all PictBridge-compatible printers.
Printing Print to network printer, PictBridge printer, or to a printer that supports e-mail printing. Note: This product includes software
developed by the OpenSSL Project for use in the OpenSSL Toolkit. (http://www.openssl.org/)
LAN port RJ-45 connector, supports 10/100/1000 Mb/s
Video out port DB-15 female connector, connect to show the oscilloscope display on an external monitor or projector. XGA resolution.
Probe compensator output voltage
and frequency
Front-panel pins
Amplitude 0 to 2.5 V
Frequency 1 kHz
Auxiliary out Rear-panel BNC connector
VOUT (Hi): ≥2.5 V open circuit, ≥1.0 V 50 Ω to ground
VOUT (Lo): ≤0.7 V into a load of ≤4 mA; ≤0.25 V 50 Ω to ground
Output can be configured to provide a pulse out signal when the oscilloscope triggers, the internal oscilloscope reference clock
out, or an event out for limit/mask testing.
External reference input Time-base system can phase lock to an external 10 MHz reference (10 MHz ±1%)
Kensington-style lock Rear-panel security slot connects to standard Kensington-style lock.
VESA mount Standard (MIS-D 100) 100 mm VESA mounting points on rear of instrument.
Mixed Domain Oscilloscopes — MDO4000B Series
www.tektronix.com 29
LAN eXtensions for Instrumentation (LXI)
Class LXI Class C
Version V1.3
Power source
Power source voltage 100 to 240 V ±10%
Power source frequency 50 to 60 Hz ±10% at 100 to 240 V ±10%
400 Hz ±10% at 115 V ±13%
Power consumption 250 W maximum
Physical characteristics
Dimensions mm in.
Height 229 9.0
Width 439 17.3
Depth 147 5.8
Weight kg lb.
Net 5 11
Shipping 10.7 23.6
Rackmount configuration 5U
Cooling clearance 2 in. (51 mm) required on left side and rear of instrument
EMC, environment, and safety
Temperature
Operating 0 ºC to +50 ºC (+32 ºF to 122 ºF)
Nonoperating -20 ºC to +60 ºC (-4 ºF to 140 ºF)
Humidity
Operating High: 40 ºC to 50 ºC, 10% to 60% relative humidity, Low: 0 ºC to 40 ºC, 10% to 90% relative humidity
Nonoperating High: 40 ºC to 60 ºC, 5%to 60% relative humidity, Low: 0 ºC to 40 ºC, 5% to 90% relative humidity
Altitude
Operating 3,000 meters (9,843 feet)
Nonoperating 9,144 meters (30,000 feet)
Regulatory
Electromagnetic compatibility EC Council Directive 2004/108/EC
Safety UL61010-1:2004, CAN/CSA-C22.2 No. 61010.1: 2004, Low Voltage Directive 2006/95/EC and EN61010-1:2001,
IEC 61010-1:2001, ANSI 61010-1-2004, ISA 82.02.01
Datasheet
30 www.tektronix.com
Ordering information
MDO4000B family
MDO4014B-3 Mixed Domain Oscilloscope with (4) 100 MHz analog channels, (16) digital channels, and (1) 3 GHz spectrum analyzer input
MDO4034B-3 Mixed Domain Oscilloscope with (4) 350 MHz analog channels, (16) digital channels, and (1) 3 GHz spectrum analyzer input
MDO4054B-3 Mixed Domain Oscilloscope with (4) 500 MHz analog channels, (16) digital channels, and (1) 3 GHz spectrum analyzer input
MDO4054B-6 Mixed Domain Oscilloscope with (4) 500 MHz analog channels, (16) digital channels, and (1) 6 GHz spectrum analyzer input
MDO4104B-3 Mixed Domain Oscilloscope with (4) 1 GHz analog channels, (16) digital channels, and (1) 3 GHz spectrum analyzer input
MDO4104B-6 Mixed Domain Oscilloscope with (4) 1 GHz analog channels, (16) digital channels, and (1) 6 GHz spectrum analyzer input
Standard accessories
Probes
≤ 500 MHz models TPP0500B, 500 MHz bandwidth, 10X, 3.9 pF. One passive voltage probe per analog channel.
1 GHz models TPP1000, 1 GHz bandwidth, 10X, 3.9 pF. One passive voltage probe per analog channel.
All models One P6616 16-channel logic probe and a logic probe accessory kit (020-2662-xx).
Accessories
200-5130-xx Front cover
103-0045-00 N-to-BNC adapter
063-4367-xx Documentation CD
016-2030-xx Accessory bag
User manual
Power cord
OpenChoice® Desktop Software
Calibration certificate documenting traceability to National Metrology Institute(s) and ISO9001 quality system registration
Warranty
Three-year warranty covering all parts and labor on the MDO4000B instrument. One-year warranty covering parts and labor on included probes.
Mixed Domain Oscilloscopes — MDO4000B Series
www.tektronix.com 31
Application Modules
Application modules have licenses which can be transferred between an application module and an oscilloscope. The license may be contained in the module; allowing the
module to be moved from one instrument to another. Or, the license can be contained in the oscilloscope; allowing the module to be removed and stored for safekeeping.
Transferring the license to an oscilloscope and removing the module permits the use of more than 4 applications simultaneously.
DPO4BND Application bundle module that enables all of the functionality of the DPO4AERO, DPO4AUDIO, DPO4AUTO, DPO4COMP,
DPO4EMBD, DPO4ENET, DPO4LMT, DPO4PWR, DPO4USB and DPO4VID application modules in a single module. Save
money when multiple serial bus debug and analysis application modules are required and easily move the entire set of
functionality from one instrument to another.
DPO4AERO Aerospace Serial Triggering and Analysis Module. Enables triggering on packet-level information on MIL-STD-1553 buses as well
as analytical tools such as digital views of the signal, bus views, packet decoding, search tools, and packet decode tables with
time-stamp information.
Signal Inputs - Any Ch1 - Ch4, Math, Ref1 - Ref4
Recommended Probing - Differential or single ended (only one single-ended signal required)
DPO4AUDIO Audio Serial Triggering and Analysis Module. Enables triggering on packet-level information on I2S, LJ, RJ, and TDM audio buses
as well as analytical tools such as digital views of the signal, bus views, packet decoding, search tools, and packet decode tables
with time-stamp information.
Signal Inputs - Any Ch1 - Ch4, any D0 - D15
Recommended Probing - Single ended
DPO4AUTO Automotive Serial Triggering and Analysis Module. Enables triggering on packet-level information on CAN and LIN buses as well
as analytical tools such as digital views of the signal, bus views, packet decoding, search tools, and packet decode tables with
time-stamp information.
Signal Inputs - LIN: Any Ch1 - Ch4, any D0 - D15; CAN: Any Ch1 - Ch4, any D0 - D15
Recommended Probing - LIN: Single ended; CAN: Single ended or differential
DPO4AUTOMAX Extended Automotive Serial Triggering and Analysis Module. Enables triggering on packet-level information on CAN, LIN, and
FlexRay buses as well as analytical tools such as digital views of the signal, bus views, packet decoding, search tools, packet
decode tables with time-stamp information, and eye diagram analysis software.
Signal Inputs - LIN: Any Ch1 - Ch4, any D0 - D15; CAN: Any Ch1 - Ch4, any D0 - D15; FlexRay: Any Ch1 - Ch4, any D0 - D15
Recommended Probing - LIN: Single ended; CAN, FlexRay: Single ended or differential
DPO4COMP Computer Serial Triggering and Analysis Module. Enables triggering on packet-level information on RS-232/422/485/UART buses
as well as analytical tools such as digital views of the signal, bus views, packet decoding, search tools, and packet decode tables
with time-stamp information.
Signal Inputs - Any Ch1 - Ch4, any D0 - D15
Recommended Probing - RS-232/UART: Single ended; RS-422/485: Differential
DPO4EMBD Embedded Serial Triggering and Analysis Module. Enables triggering on packet-level information on I2C and SPI buses as well as
analytical tools such as digital views of the signal, bus views, packet decoding, search tools, and packet decode tables with time-
stamp information.
Signal Inputs - I2C: Any Ch1 - Ch4, any D0 - D15; SPI: Any Ch1 - Ch4, any D0 - D15
Recommended Probing - Single ended
DPO4ENET Ethernet Serial Triggering and Analysis Module. Enables triggering on packet-level information on 10BASE-T and 100BASE-TX 5
buses as well as analytical tools such as digital views of the signal, bus views, packet decoding, search tools, and packet decode
tables with time-stamp information.
Signal Inputs - Any Ch1 - Ch4, Math, Ref1 - Ref4
Recommended Probing - 10BASE-T: Single ended or differential; 100BASE-TX: Differential
5≥350 MHz bandwidth models are recommended for 100BASE-TX
Datasheet
32 www.tektronix.com
DPO4USB USB Serial Triggering and Analysis Module. Enables triggering on packet-level content for low-speed, full-speed, and high-speed
USB serial buses. Also enables analytical tools such as digital views of the signal, bus views, packet decoding, search tools, and
packet decode tables with time-stamp information for low-speed, full-speed, and high-speed USB serial buses. 6
Signal Inputs - Low-speed and Full-speed: Any Ch1 - Ch4, any D0 - D15; Low-speed, Full-speed, and High-speed: Any Ch1 - Ch4,
Math, Ref1 - Ref4
Recommended Probing - Low-speed and Full-speed: Single ended or differential; High-speed: Differential
DPO4PWR Power Analysis Application Module. Enables quick and accurate analysis of power quality, switching loss, harmonics, safe
operating area (SOA), modulation, ripple, and slew rate (dI/dt, dV/dt).
DPO4LMT Limit and Mask Testing Application Module. Enables testing against limit templates generated from "golden" waveforms and mask
testing using custom or standard telecommunications or computer masks. 7
DPO4VID HDTV and Custom (nonstandard) Video Triggering and Video Picture Module.
MDO4TRIG Advanced RF Power Level Triggering Module. Enables the power level on the spectrum analyzer input to be used as a source in
the following trigger types: Pulse Width, Runt, Timeout, Logic, and Sequence.
Instrument options
Power cord and plug options
Opt. A0 North America power plug (115 V, 60 Hz)
Opt. A1 Universal Euro power plug (220 V, 50 Hz)
Opt. A2 United Kingdom power plug (240 V, 50 Hz)
Opt. A3 Australia power plug (240 V, 50 Hz)
Opt. A5 Switzerland power plug (220 V, 50 Hz)
Opt. A6 Japan power plug (100 V, 50/60 Hz)
Opt. A10 China power plug (50 Hz)
Opt. A11 India power plug (50 Hz)
Opt. A12 Brazil power plug (60 Hz)
Opt. A99 No power cord
Language options
Opt. L0 English manual
Opt. L1 French manual
Opt. L2 Italian manual
Opt. L3 German manual
Opt. L4 Spanish manual
Opt. L5 Japanese manual
Opt. L6 Portuguese manual
Opt. L7 Simplified Chinese manual
Opt. L8 Traditional Chinese manual
6USB high-speed supported only on models with 1 GHz analog channel bandwidth.
7≥350 MHz bandwidth models are recommended for mask testing on telecomm standards >55 Mb/s. 1 GHz bandwidth models are recommended for mask testing on high-speed (HS) USB.
Mixed Domain Oscilloscopes — MDO4000B Series
www.tektronix.com 33
Opt. L9 Korean manual
Opt. L10 Russian manual
Opt. L99 No manual
Language options include translated front-panel overlay for the selected language(s).
Service options
Opt. C3 Calibration Service 3 Years
Opt. C5 Calibration Service 5 Years
Opt. D1 Calibration Data Report
Opt. D3 Calibration Data Report 3 Years (with Opt. C3)
Opt. D5 Calibration Data Report 5 Years (with Opt. C5)
Opt. G3 Complete Care 3 Years (includes loaner, scheduled calibration, and more)
Opt. G5 Complete Care 5 Years (includes loaner, scheduled calibration, and more)
Opt. R5 Repair Service 5 Years (including warranty)
Opt. SILV900 Standard warranty extended to 5 years
Probes and accessories are not covered by the oscilloscope warranty and service offerings. Refer to the datasheet of each probe and accessory model for its unique warranty
and calibration terms.
Recommended accessories
Probes
Tektronix offers over 100 different probes to meet your application needs. For a comprehensive listing of available probes, please visit www.tektronix.com/probes.
TPP0500B 500 MHz, 10X TekVPI® passive voltage probe with 3.9 pF input capacitance
TPP0502 500 MHz, 2X TekVPI® passive voltage probe with 12.7 pF input capacitance
TPP0850 2.5 kV, 800 MHz, 50X TekVPI® passive high-voltage probe
TPP1000 1 GHz, 10X TekVPI® passive voltage probe with 3.9 pF input capacitance
TAP1500 1.5 GHz TekVPI® active single-ended voltage probe
TAP2500 2.5 GHz TekVPI® active single-ended voltage probe
TAP3500 3.5 GHz TekVPI® active single-ended voltage probe
TCP0030 120 MHz TekVPI® 30 Ampere AC/DC current probe
TCP0150 20 MHz TekVPI® 150 Ampere AC/DC current probe
TDP0500 500 MHz TekVPI® differential voltage probe with ±42 V differential input voltage
TDP1000 1 GHz TekVPI® differential voltage probe with ±42 V differential input voltage
TDP1500 1.5 GHz TekVPI® differential voltage probe with ±8.5 V differential input voltage
TDP3500 3.5 GHz TekVPI® differential voltage probe with ±2 V differential input voltage
THDP0200 ±1.5 kV, 200 MHz TekVPI® high-voltage differential probe
THDP0100 ±6 kV, 100 MHz TekVPI® high-voltage differential probe
TMDP0200 ±750 V, 200 MHz TekVPI® high-voltage differential probe
Datasheet
34 www.tektronix.com
P5100A 2.5 kV, 500 MHz, 100X high-voltage passive probe
P5200A 1.3 kV, 50 MHz high-voltage differential probe
Accessories
TPA-N-PRE Preamplifier, 12 dB nominal Gain, 9 kHz - 6 GHz
119-4146-00 Near field probe set, 100 kHz - 1 GHz
119-6609-00 Flexible monopole antenna
TPA-N-VPI N-to-TekVPI adapter
077-0585-xx Service manual (English only)
TPA-BNC TekVPI® to TekProbe BNC adapter
TEK-DPG TekVPI Deskew pulse generator signal source
067-1686-xx Power measurement deskew and calibration fixture
SignalVu-PC-SVE Vector Signal Analysis Software
TEK-USB-488 GPIB-to-USB adapter
ACD4000B Soft transit case
HCTEK54 Hard transit case (requires ACD4000B)
RMD5000 Rackmount kit
Other RF probes
Contact Beehive Electronics to
order:
http://beehive-electronics.com/probes.html
101A EMC probe set
150A EMC probe amplifier
110A Probe cable
0309-0001 SMA probe adapter
0309-0006 BNC probe adapter
Tektronix is registered to ISO 9001 and ISO 14001 by SRI Quality System Registrar.
Product(s) complies with IEEE Standard 488.1-1987, RS-232-C, and with Tektronix Standard Codes and Formats.
Mixed Domain Oscilloscopes — MDO4000B Series
www.tektronix.com 35
Datasheet
ASEAN / Australasia (65) 6356 3900 Austria 00800 2255 4835* Balkans, Israel, South Africa and other ISE Countries +41 52 675 3777
Belgium 00800 2255 4835* Brazil +55 (11) 3759 7627 Canada 1 800 833 9200
Central East Europe and the Baltics +41 52 675 3777 Central Europe & Greece +41 52 675 3777 Denmark +45 80 88 1401
Finland +41 52 675 3777 France 00800 2255 4835* Germany 00800 2255 4835*
Hong Kong 400 820 5835 India 000 800 650 1835 Italy 00800 2255 4835*
Japan 81 (3) 6714 3010 Luxembourg +41 52 675 3777 Mexico, Central/South America & Caribbean 52 (55) 56 04 50 90
Middle East, Asia, and North Africa +41 52 675 3777 The Netherlands 00800 2255 4835* Norway 800 16098
People's Republic of China 400 820 5835 Poland +41 52 675 3777 Portugal 80 08 12370
Republic of Korea 001 800 8255 2835 Russia & CIS +7 (495) 6647564 South Africa +41 52 675 3777
Spain 00800 2255 4835* Sweden 00800 2255 4835* Switzerland 00800 2255 4835*
Taiwan 886 (2) 2722 9622 United Kingdom & Ireland 00800 2255 4835* USA 1 800 833 9200
* European toll-free number. If not accessible, call: +41 52 675 3777 Updated 10 April 2013
For Further Information. Tektronix maintains a comprehensive, constantly expanding collection of application notes, technical briefs and other resources to help engineers working on the cutting edge of technology. Please visit www.tektronix.com.
Copyright © Tektronix, Inc. All rights reserved. Tektronix products are covered by U.S. and foreign patents, issued and pending. Information in this publication supersedes that in all previously published material. Specification and
price change privileges reserved. TEKTRONIX and TEK are registered trademarks of Tektronix, Inc. All other trade names referenced are the service marks, trademarks, or registered trademarks of their respective companies.
04 Feb 2015 48W-26875-11
www.tektronix.com