Technical Data 4401
Effective October 2017
Supersedes June 2017
Product features
•PolyTron™ radial leaded thru-hole PTC device
•Maximum 60 V
•Current ratings from 0.10 A to 3.75 A
•Fast time-to-trip
•Low resistance
•Halogen free, Lead free, RoHS compliant
Applications
•Medical equipment
•White goods
•Industrial power transmission
•Telecommunications
•Computers and peripherals
•Consumer and automotive electronics
•Rechargeable battery packs
Agency information
•cURus: Recognized Card: File E343021 (Ihold 0.1-3.75 A)
•TUV File: J 50194729
PTR060V
60 Volt DC radial leaded, PolyTron™ PTC devices
Pb
HALOGEN
HF
FREE
Ordering information/
part number system PT R 060V 0160 -TR
PolyTron™ PTC Device Series
Radial Leaded
Maximum Voltage
Current Holding (Ihold)
Tape and Reel Packaging and Lead Type Code
Lead Codes: TR & BK - Straight Leads, TR1 & BK1 - Kinked Leads
TR & TR1 On Reels BK & BK1 In Poly Bags
• 0.10-0.25 A - 1000 devices
• 0.30-1.85 A - 500 devices
• 2.50-3.75 A - 250 devices
• 0.10, 0.20-0.40 A - 3000 devices
• 0.17 - 2,500 A devices
• 0.50-0090 A - 2000 devices
• 1.10-1.85 A - 1200 devices
• 2.50-3.75 A - 1000 devices
Specications
Ihold Itrip PdTime to Resistance (Ω) Agency
Catalog Vmax Imax
@+23 °C @+23 °C
Typ. Trip (Max.) Initial (R
i) Post Trip (R
1) Information
Number (Vdc)
(A) (A) (A)
(W)
(A) (sec)
Min. Max. Max. cURus TUV
PTR060V0010 60 40 0.10 0.20 0.38 0.50 4.0 2.500 4.500 7.50 X X
PTR060V0017 60 40 0.17 0.34 0.48 0.85 3.0 3.300 5.210 8.00 X X
PTR060V0020 60 40 0.20 0.40 0.41 1.00 2.2 1.830 2.750 4.40 X X
PTR060V0025 60 40 0.25 0.50 0.45 1.25 2.5 1.250 1.950 3.00 X X
PTR060V0030 60 40 0.30 0.60 0.49 1.50 3.0 0.880 1.330 2.10 X X
PTR060V0040 60 40 0.40 0.80 0.56 2.00 3.8 0.550 0.860 1.29 X X
PTR060V0050 60 40 0.50 1.00 0.77 2.50 4.0 0.500 0.770 1.17 X X
PTR060V0065 60 40 0.65 1.30 0.88 3.25 5.3 0.310 0.480 0.72 X X
PTR060V0075 60 40 0.75 1.50 0.92 3.75 6.3 0.250 0.400 0.60 X X
PTR060V0090 60 40 0.90 1.80 0.99 4.50 7.2 0.200 0.310 0.47 X X
PTR060V0110 60 40 1.10 2.20 1.50 5.50 8.2 0.150 0.250 0.38 X X
PTR060V0135 60 40 1.35 2.70 1.70 6.75 9.6 0.120 0.190 0.30 X X
PTR060V0160 60 40 1.60 3.20 1.90 8.00 11.4 0.090 0.140 0.22 X X
PTR060V0185 60 40 1.85 3.70 2.10 9.25 12.6 0.080 0.120 0.19 X X
PTR060V0250 60 40 2.50 5.00 2.50 12.50 15.6 0.050 0.080 0.13 X X
PTR060V0300 60 40 3.00 6.00 2.80 15.00 19.8 0.040 0.060 0.10 X X
PTR060V0375 60 40 3.75 7.50 3.20 18.75 24.0 0.030 0.050 0.08 X X
Notes: Ihold – Hold current: Maximum current device will pass without interruption in +23 °C still air.
Itrip – Trip current: Minimum current that will switch the device from low resistance to high resistance in +23 °C still air.
Vmax: Maximum continuous voltage device can withstand without damage at rated current.
Imax: Maximum fault current device can withstand without damage at rated voltage.
Pd: Power dissipated from device when in the tripped state in +23 °C still air.
Ri (min.): Minimum resistance of device as supplied at +23 °C unless otherwise specified.
Ri (max.): Maximum resistance of device as supplied at +23 °C unless otherwise specified.
R1(max.): Maximum resistance of device when measured one hour post reflow (SMD) or one hour post trip (radial-leaded device) at +23 °C unless otherwise specified.