Data Sheet October 5, 2009 HC006/010 Series DC-DC Converter Power Modules: 18-36Vdc Input; 3.3V-5Vdc Output; 6.6A-10A Output Current Features RoHS Compliant Compliant to RoHS EU Directive 2002/95/EC (-Z versions) Compliant to ROHS EU Directive 2002/95/EC with lead solder exemption (non-Z versions) Delivers up to 10A Output current High efficiency - 90% at 3.3V full load Low Output voltage- supports migration to future IC supply voltages down to 1.0V Low output ripple and noise Small Size and low profile 5V (6.6A), 3.3V (10A) Applications Wireless Networks Distributed power architectures Optical and Access Network Equipment Enterprise Networks Latest generation IC's (DSP, FPGA, ASIC) and Microprocessor powered applications Options Remote On/Off logic (positive or negative) Surface Mount (-S Suffix) Trimmed leads 47.2mm x 29.5mm x 8.5mm (1.86 x 1.16 x 0.335 in) Surface mount or Through hole (TH) Remote On/Off Output overcurrent/Over voltage protection Over temperature protection Single Tightly regulated output Output voltage adjustment trim 10% Wide operating temperature range (-40C to 85C) Meets the voltage insulation requirements for ETSI 300-132-2 and complies with and is Licensed for Basic Insulation rating per EN 60950 CE mark meets 73/23/EEC and 93/68/EEC directives UL* 60950-1Recognized, CSA C22.2 No. 60950-103 Certified, and VDE 0805:2001-12 (EN60950-1) Licensed ISO** 9001 and ISO 14001 certified manufacturing facilities Description The HC series power modules are isolated dc-dc converters that operate over a wide input voltage range of 18 to 36 Vdc and provide one precisely regulated output. The output is fully isolated from the input, allowing versatile polarity configurations and grounding connections. The modules exhibit high efficiency, e.g. typical efficiency of 90% 3.3/10A, 91% at 5V/6A. Built-in filtering for both input and output minimizes the need for external filtering. These open frame modules are available either in surface-mount (-S) or in through-hole form. * UL is a registered trademark of Underwriters Laboratories, Inc. CSA is a registered trademark of Canadian Standards Association. VDE is a trademark of Verband Deutscher Elektrotechniker e.V. ** ISO is a registered trademark of the International Organization of Standards Document No: DS03-122 ver. 1.45 PDF name: hc006-010_series_ds.pdf Data Sheet October 5, 2009 HC006/010 Series DC-DC Power Module: 18-36Vdc Input; 3.3V & 5Vdc Output; 6.6A - 10A Output Current Absolute Maximum Ratings Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are absolute stress ratings only, functional operation of the device is not implied at these or any other conditions in excess of those given in the operations sections of the data sheet. Exposure to absolute maximum ratings for extended periods can adversely affect the device reliability. Parameter Device Symbol Min Max Unit Input Voltage All VIN Operating Ambient Temperature All TA -0.3 50 Vdc -40 85 C Storage Temperature All Tstg -55 125 C I/O Isolation Voltage (100% factory tested) All 1500 Vdc (see Thermal Considerations section) Electrical Specifications Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature conditions. Parameter Device Symbol Min Typ 18 24 Max Unit Operating Input Voltage HC VIN 36 Vdc Maximum Input Current HC IIN,max 3.2 Adc Inrush Transient All It 2 1 As Input Reflected Ripple Current, peak-to-peak (5Hz to 20MHz, 12H source impedance; VIN=0V to 75V, IO= IOmax ; see Figure 9) All 3 mAp-p Input Ripple Rejection (120Hz) All 50 dB (VIN=0V to 75V, IO=IO, max) EMC, EN55022 2 See EMC Considerations section CAUTION: This power module is not internally fused. An input line fuse must always be used. This power module can be used in a wide variety of applications, ranging from simple standalone operation to an integrated part of a sophisticated power architecture. To preserve maximum flexibility, internal fusing is not included, however, to achieve maximum safety and system protection, always use an input line fuse. The safety agencies require a fast-acting fuse with a maximum rating of 5A (see Safety Considerations section). Based on the information provided in this data sheet on inrush energy and maximum dc input current, the same type of fuse with a lower rating can be used. Refer to the fuse manufacturer's data sheet for further information. LINEAGE POWER 2 Data Sheet October 5, 2009 HC006/010 Series DC-DC Power Module: 18-36Vdc Input; 3.3V & 5Vdc Output; 6.6A - 10A Output Current Electrical Specifications (continued) Parameter Output Voltage Set-point (VIN=VIN,nom, IO=IO, max, Tref=25C) Output Voltage Device Symbol Min Typ Max Unit 3.3V VO, set 3.25 3.3 3.35 Vdc 5.0V VO, set 4.92 5.0 5.08 Vdc All VO -3.0 +3.0 % VO, set All VO -10.0 +10.0 % VO, set % VO, set (Over all operating input voltage, resistive load, and temperature conditions until end of life) Adjustment Range Selected by external resistor Output Regulation Line (VIN=VIN, min to VIN, max) All 0.1 Load (IO=IO, min to IO, max) All 10 mV Temperature (Tref=TA, min to TA, max) All 0.2 % VO, set All 8 20 mVrms mVpk-pk Output Ripple and Noise on nominal output (VIN=VIN, nom and IO=IO, min to IO, max) Measured across 10F tantalum//1F ceramic RMS (5Hz to 20MHz bandwidth) Peak-to-Peak (5Hz to 20MHz bandwidth) External Load Capacitance Output Current (At Io < Io,min the output ripple may exceed the The max specifications. All modules shall Operate at no load without damage and without exceeding 100% of VO, set ) Output Current Limit Inception (Vo = 90% of VO, set) Output Short-Circuit Current (VO250mV) Efficiency VIN=VIN, nom, TA=25C 40 75 3.3V CO, max 0 1000 F 5.0V CO, max 0 470 F 3.3V Io 0.05 10 Adc 5.0V Io 0.05 6.6 Adc 3.3V IO, lim 12 Adc 5.0V IO, lim 8 Adc 3.3V IO, s/c 17 Adc 5.0V IO, s/c 13 Adc 3.3V 90.0 % 5.0V 91.0 % All IO=IO, max , VO= VO,set LINEAGE POWER 3 Data Sheet October 5, 2009 HC006/010 Series DC-DC Power Module: 18-36Vdc Input; 3.3V & 5Vdc Output; 6.6A - 10A Output Current Electrical Specifications (continued) Parameter Device Symbol Min Typ Max Unit All fsw 285 kHz Vpk 200 mV All ts 200 s Peak Deviation All Vpk 200 mV Settling Time (Vo<10% peak deviation) All ts 200 s Switching Frequency Dynamic Load Response (Io/t=0.1A/s; Vin=Vin,nom; TA=25C) Load Change from Io= 50% to 75% of Io,max Peak Deviation Settling Time (Vo<10% peak deviation) (Io/t=0.1A/s; Vin=Vin,nom; TA=25C) Load Change from Io= 75% to 50% of Io,max Isolation Specifications Parameter Symbol Min Typ Max Unit Isolation Capacitance Ciso 1000 pF Isolation Resistance Riso 10 M General Specifications Parameter Min Calculated MTBF (for HC010A0F1 in accordance with Lucent RIN: IO=80% of IO, max, TA=25C, airflow=1m/s) Weight LINEAGE POWER Typ Max > TBD 13 (0.46) Unit Hours Weight 4 Data Sheet October 5, 2009 HC006/010 Series DC-DC Power Module: 18-36Vdc Input; 3.3V & 5Vdc Output; 6.6A - 10A Output Current Feature Specifications Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature conditions. See Feature Descriptions for additional information. Parameter Device Symbol Min Typ Max Unit All Ion/off 0.15 1.0 mA All Von/off -0.7 1.2 V Logic High - (Typ = Open Collector) All Von/off 15 V Logic High maximum allowable leakage current All Ion/off 50 A All Tdelay 20 msec All Tdelay 12 msec Remote On/Off Signal Interface (VIN=VIN, min to VIN, max ; open collector or equivalent, Signal referenced to VIN- terminal) Negative Logic: device code suffix "1" Logic Low = module On, Logic High = module Off Positive Logic: No device code suffix required Logic Low = module Off, Logic High = module On Logic Low Specification Remote On/Off Current - Logic Low On/Off Voltage: Logic Low Turn-On Delay and Rise Times (VIN=VIN, nom, IO=IO, max , VO to within 1% of steady state) Case 1: On/Off input is set to Logic high and then input power is applied (delay from instant at which VI = VI,min until Vo = 10% of Vo, set) Case 2: Input power is applied for at least one second and then the On/Off input is set to logic high (delay from instant at which Von/Off = 0.9V until Vo = 10% of Vo, set) Output voltage Rise time (time for Vo to rise from 10% of Vo, set to 90% of Vo, set) Output voltage overshoot (VIN=VIN, nom, Io = 80% of Io,max, TA=25C) Output Overvoltage Protection Overtemperature Protection All Trise All 5 5 msec %VO, set 3.3V VO, limit 4.0 4.6 5.0V VO, limit 6.1 7.0 V All Tref 125 C V (See Feature Descriptions) Input Undervoltage Lockout Turn-on Threshold HC 16 18 V Turn-off Threshold HC 13 14 V LINEAGE POWER 5 Data Sheet October 5, 2009 HC006/010 Series DC-DC Power Module: 18-36Vdc Input; 3.3V & 5Vdc Output; 6.6A - 10A Output Current Characteristic Curves 94 12 90 10 OUTPUT CURRENT, Io (A) EFFICIENCY, (%) The following figures provide typical characteristics for the HC010A0F (3.3V, 10A) at 25C. The figures are identical for either positive or negative Remote On/Off logic. 86 82 VIN = 18V 78 VIN = 24V 74 VIN = 36V 70 0 2 4 6 8 10 0.5m/s (100 LFM ) 2 1.0m/s (200 LFM ) 0 20 30 40 50 60 70 80 90 AMBIENT TEMPERATURE, TA C OUTPUT VOLTAGE VO (V) (1V/div) TIME, t (20ms/div) Figure 3. Transient Response to Dynamic Load Change from 50% to 75% to 50% of full load. LINEAGE POWER VON/OFF(V) (10V/div) IO (A) (2A/div) TIME, t (100s/div) VO (V) (1V/div) Figure 5. Typical Start-Up with application of Vin (VIN =24Vdc, Io = 10A). VO (V) (200mV/div) Figure 2. Typical Output Ripple and Noise. On/Off VOLTAGE OUTPUT VOLTAGE VIN (V) (20V/div) Figure 4. Derating Output Current versus Local Ambient Temperature and Airflow INPUT VOLTAGE VO (V) (20mV/div) OUTPUT VOLTAGE, NC 4 OUTPUT CURRENT, OUTPUT VOLTAGE TIME, t (1s/div) 6 O OUTPUT CURRENT, IO (A) Figure 1. Converter Efficiency versus Output Current 8 TIME, t (20ms/div) Figure 6. Typical Start-Up Using Remote On/Off, negative logic version shown. 6 Data Sheet October 5, 2009 HC006/010 Series DC-DC Power Module: 18-36Vdc Input; 3.3V & 5Vdc Output; 6.6A - 10A Output Current Characteristic Curves (continued) The following figures provide typical characteristics for the HC006A6A (5.0V,6.6A) at 25C. The figures are identical for either positive or negative Remote On/Off logic. 8 94% OUTPUT CURRENT, Io (A) EFFICIENCY, (%) 90% 86% 82% Vin=18V 78% Vin=24V 74% Vin=36V 70% 0 1 2 3 4 5 6 1.0m/s (200 LFM ) 0 20 30 40 50 60 70 80 90 VO (V) (1V/div) VIN (V) (20V/div) INPUT VOLTAGE, OUTPUT VOLTAGE TIME, t (20ms/div) VO (V) (1V/div) Figure 11. Typical Start-Up with application of Vin (VIN =48Vdc, Io = 6.6A). On/Off VOLTAGE TIME, t (100s/div) Figure 9. Transient Response to Dynamic Load Change from 50% to 75% to 50% of full load. 0.5m/s (100 LFM ) 2 Figure 10. Derating Output Current versus Local Ambient Temperature and Airflow OUTPUT VOLTAGE VO (V) (200mV/div) IO (A) (2A/div) OUTPUT CURRENT, OUTPUT VOLTAGE Figure 8. Typical Output Ripple and Noise (VIN =24Vdc, Io = 6.6A). NC 3 AMBIENT TEMPERATURE, TA C VON/OFF(V) (10V/div) VO (V) (20mV/div) OUTPUT VOLTAGE, TIME, t (1s/div) 5 O OUTPUT CURRENT, IO (A) Figure 7. Converter Efficiency versus Output Current 6 TIME, t (20ms/div) Figure 12. Typical Start-Up Using Remote On/Off, negative logic version shown (VIN =24Vdc, Io = 6.6A). 7 Data Sheet October 5, 2009 HC006/010 Series DC-DC Power Module: 18-36Vdc Input; 3.3V & 5Vdc Output; 6.6A - 10A Output Current Test Configurations Design Considerations CURRENT PROBE TO OSCILLOSCOPE The power module should be connected to a low ac-impedance source. A highly inductive source impedance can affect the stability of the power module. For the test configuration in Figure 13, a 33F electrolytic capacitor (ESR<0.7 at 100kHz), mounted close to the power module helps ensure the stability of the unit. Consult the factory for further application guidelines. LTEST Vin+ BATTERY 12H CS 220F 33F E.S.R.<0.1 @ 20C 100kHz Vin- NOTE: Measure input reflected ripple current with a simulated source inductance (LTEST) of 12H. Capacitor CS offsets possible battery impedance. Measure current as shown above. Figure 13. Input Reflected Ripple Current Test Setup. COPPER STRIP VO (+) RESISTIVE LOAD 1uF . 10uF Input Source Impedance SCOPE V O (-) GROUND PLANE NOTE: All voltage measurements to be taken at the module terminals, as shown above. If sockets are used then Kelvin connections are required at the module terminals to avoid measurement errors due to socket contact resistance. Safety Considerations For safety-agency approval of the system in which the power module is used, the power module must be installed in compliance with the spacing and separation requirements of the end-use safety agency standard, i.e., UL 60950-1-3, CSA C22.2 No. 60950-00, and VDE 0805:2001-12 (IEC60950-1). If the input source is non-SELV (ELV or a hazardous voltage greater than 60 Vdc and less than or equal to 75Vdc), for the module's output to be considered as meeting the requirements for safety extra-low voltage (SELV), all of the following must be true: The input source is to be provided with reinforced insulation from any other hazardous voltages, including the ac mains. One VIN pin and one VOUT pin are to be grounded, or both the input and output pins are to be kept floating. The input pins of the module are not operator accessible. Another SELV reliability test is conducted on the whole system (combination of supply source and subject module), as required by the safety agencies, to verify that under a single fault, hazardous voltages do not appear at the module's output. Figure 14. Output Ripple and Noise Test Setup. Rdistribution Rcontact Rcontact Vin+ RLOAD VO VIN Rdistribution Rcontact Rcontact Vin- Rdistribution Vout+ Rdistribution Vout- NOTE: All voltage measurements to be taken at the module terminals, as shown above. If sockets are used then Kelvin connections are required at the module terminals to avoid measurement errors due to socket contact resistance. Figure 15. Output Voltage and Efficiency Test Setup. VO. IO Efficiency = LINEAGE POWER VIN. IIN x 100 % Note: Do not ground either of the input pins of the module without grounding one of the output pins. This may allow a non-SELV voltage to appear between the output pins and ground. The power module has extra-low voltage (ELV) outputs when all inputs are ELV. For input voltages exceeding -60 Vdc but less than or equal to -75 Vdc, these converters have been evaluated to the applicable requirements of BASIC INSULATION between secondary DC MAINS DISTRIBUTION input (classified as TNV-2 in Europe) and unearthed SELV outputs."All flammable materials used in the manufacturing of these modules are rated 94V-0 and UL60950 A.2 for reduced thicknesses. The input to these units is to be provided with a maximum 3A fastacting fuse in the unearthed lead." 8 Data Sheet October 5, 2009 HC006/010 Series DC-DC Power Module: 18-36Vdc Input; 3.3V & 5Vdc Output; 6.6A - 10A Output Current begin to operate at an input voltage above the undervoltage lockout turn-on threshold. Feature Description Remote On/Off Two remote on/off options are available. Positive logic turns the module on during a logic high voltage on the ON/OFF pin, and off during a logic low. Negative logic remote On/Off, device code suffix "1", turns the module off during a logic high and on during a logic low. VIN(+) VO Ion/off ON/OFF Von/off Over Voltage Protection The output overvoltage protection clamp consists of control circuitry, independent of the primary regulation loop, that monitors the voltage on the output terminals. This control loop has a higher voltage set point than the primary loop (See the overvoltage clamp values in the Feature Specifications Table). In a fault condition, the overvoltage clamp ensures that the output voltage does not exceed Vo,ovsd, max. This provides a redundant voltage-control that reduces the risk of output overvoltage. Over Temperature Protection COM VIN(-) To provide protection in a fault condition, the unit is equipped with a thermal shutdown circuit. The unit will o shutdown if the overtemperature threshold of 125 C is exceeded at the thermal reference point Tref . Once the unit goes into thermal shutdown it will then wait to cool before attempting to restart. Output Voltage Programming Figure 16. Remote On/Off Implementation. To turn the power module on and off, the user must supply a switch (open collector or equivalent) to control the voltage (Von/off) between the ON/OFF terminal and the VIN(-) terminal. Logic low is -0.7V Von/off 1.2V. The maximum Ion/off during a logic low is 1mA, the switch should be maintain a logic low level whilst sinking this current. During a logic high, the maximum Von/off generated by the module is 15V, and the maximum allowable leakage current at Von/off = 15V is 50A. If not using the remote on/off feature: For positive logic, leave the ON/OFF pin open. For negative logic, short the ON/OFF pin to VIN(-). Trimming allows the output voltage set point to be increased or decreased, this is accomplished by connecting an external resistor between the TRIM pin and either the VO(+) pin or the VO(-) pin (COM pin) . VIN(+) VO(+) Rtrim-up ON/OFF LOAD VOTRIM Rtrim-down VIN(-) COM Overcurrent Protection To provide protection in a fault (output overload) condition, the module is equipped with internal current-limiting circuitry, and can endure current limiting continuously. At the instance of current-limit inception, the output current begins to tail-out. When an overcurrent condition exists beyond a few seconds, the module enters a "hiccup" mode of operation, whereby it shuts down and automatically attempts to restart upon cooling. While the fault condition exists, the module will remain in this hiccup mode, and can remain in this mode until the fault is cleared. The unit operates normally once the output current is reduced back into its specified range. Figure 17. Circuit Configuration to Trim Output Voltage. Connecting an external resistor (Rtrim-down) between the TRIM pin and the COM pin decreases the output voltage set point. The following equation determines the value of trim-down resistor needed to decrease the output voltage from Vo,set to Vo: Input Undervoltage Lockout At input voltages below the input undervoltage lockout limit, the module operation is disabled. The module will LINEAGE POWER 9 Data Sheet October 5, 2009 HC006/010 Series DC-DC Power Module: 18-36Vdc Input; 3.3V & 5Vdc Output; 6.6A - 10A Output Current 45.5(100 + 10) - 1690 Rtrim - up = - 73.1k 10 Feature Descriptions (continued) Output Voltage Programming (continued) Rtrim - up = 258.4k A Rtrim - down = - B k % Rtrim-down is the external resistor in k % is the % change in output voltage Values of A & B are provided in Table 1 Table 1 Output Voltage A B 3.3V 1690 73.1 5.0V 1690 73.1 (V) Connecting an external resistor (Rtrim-up) between the TRIM pin and the VO(+) pin increases the output voltage set point. The relationship between the output voltage and the trim resistor value for a % increase in output voltage is: A(100 + % - B Rtrim - up = - C k % Rtrim-up is the external resistor in k % is the % change in output voltage Values of A , B and C are provided in Table 2 Table 2 Output Voltage (V) A B V 3.3 45.5 1690 73.1 5.0 69.0 1690 73.1 Examples: To trim down the output of a nominal 5.0V module (HC006A6A) to 4.90V % = 2 1690 Rtrim - down = - 73.1 k 2 Rtrim - down = 771.9k To trim up the output of a nominal 3.3V module (HC010A0F) to 3.63V % = 10 LINEAGE POWER 10 Data Sheet October 5, 2009 HC006/010 Series DC-DC Power Module: 18-36Vdc Input; 3.3V & 5Vdc Output; 6.6A - 10A Output Current Thermal Considerations The power modules operate in a variety of thermal environments; however, sufficient cooling should be provided to help ensure reliable operation. Considerations include ambient temperature, airflow, module power dissipation, and the need for increased reliability. A reduction in the operating temperature of the module will result in an increase in reliability. The thermal data presented here is based on physical measurements taken in a wind tunnel. The thermal reference point, Tref used in the specifications is shown in Figure 18. For reliable operation this temperature should not exceed 110 oC Figure 19. Suggested Configuration for EN55022 Class B. For further information on designing for EMC compliance, please refer to the FLTR100V10 data sheet (FDS01-043EPS). Layout Considerations Q203 Tref Airflow Figure 18. Tref Temperature Measurement Location. Please refer to the Application Note "Thermal Characterization Process For Open-Frame BoardMounted Power Modules" for a detailed discussion of thermal aspects including maximum device temperatures. The HC power module series are low profile in order to be used in fine pitch system card architectures. As such, component clearance between the bottom of the power module and the mounting board is limited. Avoid placing copper areas on the outer layer directly underneath the power module. Also avoid placing via interconnects underneath the power module. For additional layout guide-lines, refer to FLTR100V10 data sheet. Heat Transfer via Convection Increased airflow over the module enhances the heat transfer via convection. Derating figures showing the maximum output current that can be delivered by each module versus local ambient temperature (TA) for natural convection and up to 3m/s (600 ft./min) are shown in the respective Characteristics Curves section. EMC Considerations The figure 19 shows a suggested configuration to meet the conducted emission limits of EN55022 Class B. LINEAGE POWER 11 Data Sheet October 5, 2009 HC006/010 Series DC-DC Power Module: 18-36Vdc Input; 3.3V & 5Vdc Output; 6.6A - 10A Output Current Mechanical Outline for Surface-Mount Module Dimensions are in millimeters and (inches). Tolerances: x.x mm 0.5 mm (x.xx in. 0.02 in.) [Unless otherwise indicated] x.xx mm 0.25 mm (x.xxx in 0.010 in.) 47.2 (1.86) Top View 18 17 11 2 9 29.5 (1.16) 1 Side View 0.06 x 0.06 chamffer 8.50 (0.335) MAX 2.5 (0.10) min stand-off height 0.5 (.020) max compliance Bottom View 1.7 (0.07) 3.6 (0.14) TRIM VO+ VO- Pin Function 1 Vo(+) 2 Vo(-) 9 Trim 11 On/Off 17 Vin(-) 18 Vin(+) 26.16 (1.030) On/Off VI+ VI5.00 (0.197) 35.00 (1.375) 40.00 (1.575) LINEAGE POWER 12 Data Sheet October 5, 2009 HC006/010 Series DC-DC Power Module: 18-36Vdc Input; 3.3V & 5Vdc Output; 6.6A - 10A Output Current Mechanical Outline for Through Hole Module Dimensions are in millimeters and [inches]. Tolerances: x.x mm 0.5 mm [x.xx in. 0.02 in.] (Unless otherwise indicated) x.xx mm 0.25 mm [x.xxx in 0.010 in.] Top View Side View * Optional pin lengths shown in Table 2 Device Options Bottom View Pin Function 1 Vo(+) 2 Vo(-) 9 Trim 11 On/Off 17 Vin(-) 18 Vin(+) LINEAGE POWER 13 Data Sheet October 5, 2009 HC006/010 Series DC-DC Power Module: 18-36Vdc Input; 3.3V & 5Vdc Output; 6.6A - 10A Output Current Recommended Pad Layout for Surface Mount and Through Hole Module Dimensions are in millimeters and [inches]. Tolerances: x.x mm 0.5 mm [x.xx in. 0.02 in.] (Unless otherwise indicated) x.xx mm 0.25 mm [x.xxx in 0.010 in.] LINEAGE POWER 14 Data Sheet October 5, 2009 HC006/010 Series DC-DC Power Module: 18-36Vdc Input; 3.3V & 5Vdc Output; 6.6A - 10A Output Current Packaging Details The surface mount versions of the HW005 family are also available in tape & reel (suffix -SR) as an option. Detailed of tape dimensions are shown below. Modules are shipped in quantities of 115 per reel. Tape Dimensions Dimensions are in millimeters and (inches). PICK POINT 4.00 (0.157) 9.02 (0.355) 40.00 (1.575) FEED DIRECTION 34.20 (1.346) 72.00 (2.834) 68.40 (2.692) 66.50 (2.692) TOP COVER TAPE EMBOSSED CARRIER NOTE: CONFORMS TO EAI-481 REV. A STANDARD Reel Dimensions Outside diameter: Inside diameter: Tape Width: LINEAGE POWER 330.2 mm (13.00") 177.8 mm (7.00") 72.00 mm (2.834") 15 Data Sheet October 5, 2009 HC006/010 Series DC-DC Power Module: 18-36Vdc Input; 3.3V & 5Vdc Output; 6.6A - 10A Output Current Through-Hole Lead-Free Soldering Information The RoHS-compliant through-hole products use the SAC (Sn/Ag/Cu) Pb-free solder and RoHS-compliant components. They are designed to be processed through single or dual wave soldering machines. The pins have an RoHS-compliant finish that is compatible with both Pb and Pb-free wave soldering processes. A maximum preheat rate of 3C/s is suggested. The wave preheat process should be such that the temperature of the power module board is kept below 210C. For Pb solder, the recommended pot temperature is 260C, while the Pb-free solder pot is 270C max. Not all RoHS-compliant through-hole products can be processed with paste-through-hole Pb or Pb-free reflow process. If additional information is needed, please consult with your Lineage Power representative for more details. Surface Mount Information Packaging Details The surface mount versions of the HC family (suffix - S) are supplied as standard in the plastic tray shown in Figure 21. The tray has external dimensions of 136mm (W) x 322.6mm (L) x 18.4mm (H) or 5.35in (W) x 12.7in (L) x 0.72in (H). Figure 21. Surface Mount Packaging Tray Tray Specification Material Max temperature Antistatic coated PVC o 65 C Max surface resistivity Colour Capacity Min order quantity trays) 10 /sq Clear 15 power modules 45 pcs (1box of 3 full 12 Each tray contains a total of 15 power modules. The trays are self-stacking and each shipping box will contain 3 full trays plus one empty hold down tray giving a total number of 45 power modules. Pick and Place The HC-S series of DC-to-DC power converters use an open-frame construction and are designed for surface mount assembly within a fully automated manufacturing process. The HC-S series modules are fitted with a Kapton label designed to provide a large flat surface for pick and placing. The label is located covering the Centre of Gravity of the power module. The label meets all the requirements for surface-mount processing, as well as meeting UL safety agency standards. The label will withstand reflow temperatures up to 300C. The label also carries product information such as product code, date and location of manufacture. LINEAGE POWER 16 Data Sheet October 5, 2009 HC006/010 Series DC-DC Power Module: 18-36Vdc Input; 3.3V & 5Vdc Output; 6.6A - 10A Output Current Surface Mount Information (continued) damage to the modules, and can adversely affect long-term reliability. The surface mountable modules in the HC family use our newest SMT technology called "Column Pin" (CP) connectors. Fig 23 shows the new CP connector before and after reflow soldering onto the end-board assembly. X HC Board 14mm (0.57in) Insulator Solder Ball 21mm (0.84in) Nozzle Recommendations The module weight has been kept to a minimum by using open frame construction. Even so, they have a relatively large mass when compared with conventional SMT components. Variables such as nozzle size, tip style, vacuum pressure and placement speed should be considered to optimize this process. The minimum recommended nozzle diameter for reliable operation is 6mm. The maximum nozzle outer diameter, which will safely fit within the allowable component spacing, is 9 mm. Oblong or oval nozzles up to 11 x 9 mm may also be used within the space available. For further information please contact your local Lineage Power Technical Sales Representative. Reflow Soldering Information The HC family of power modules is available for either Through-Hole (TH) or Surface Mount (SMT) soldering. These power modules are large mass, low thermal resistance devices and typically heat up slower than other SMT components. It is recommended that the customer review data sheets in order to customize the solder reflow profile for each application board assembly. The following instructions must be observed when SMT soldering these units. Failure to observe these instructions may result in the failure of or cause LINEAGE POWER Figure 23. Column Pin Connector Before and After Reflow Soldering. The CP is constructed from a solid copper pin with an integral solder ball attached, which is composed of tin/lead (Sn/Pb) solder. The CP connector design is able to compensate for large amounts of co-planarity and still ensure a reliable SMT solder joint. Typically, the eutectic solder melts at 183oC, wets the land, and subsequently wicks the device connection. Sufficient time must be allowed to fuse the plating on the connection to ensure a reliable solder joint. There are several types of SMT reflow technologies currently used in the industry. These surface mount power modules can be reliably soldered using natural forced convection, IR (radiant infrared), or a combination of convection/IR. For reliable soldering the solder reflow profile should be established by accurately measuring the modules CP connector temperatures. 300 P eak Temp 235oC 250 REFLOW TEMP (C) Note: All dimensions in mm. Figure 22. Pick and Place Location. Z Plane Height The `Z' plane height of the pick and place location is 7.50mm nominal with an RSS tolerance of +/-0.25 mm. End assembly PCB 200 Co o ling zo ne 1-4oCs -1 Heat zo ne max 4oCs -1 150 100 50 So ak zo ne 30-240s Tlim above 205oC P reheat zo ne max 4oCs -1 0 REFLOW TIME (S) Figure 24. Recommended Reflow Profile 17 Data Sheet October 5, 2009 HC006/010 Series DC-DC Power Module: 18-36Vdc Input; 3.3V & 5Vdc Output; 6.6A - 10A Output Current Surface Mount Information (continued) 240 MSL Rating The HW/HC series SMT modules have a MSL rating of 1. 235 MAX TEMP SOLDER (C) stored at the following conditions: < 40 C, < 90% relative humidity. 230 Post Solder Cleaning and Drying Considerations 225 220 215 210 205 200 0 10 20 30 40 50 60 TIME LIMIT (S) Figure 25. Time Limit Curve Above 205oC Reflow . Post solder cleaning is usually the final circuit-board assembly process prior to electrical board testing. The result of inadequate cleaning and drying can affect both the reliability of a power module and the testability of the finished circuit-board assembly. For guidance on appropriate soldering, cleaning and drying procedures, refer to Lineage Power Board Mounted Power Modules: Soldering and Cleaning Application Note (AP01-056EPS). 300 Per J-STD-020 Rev. C Lead Free Soldering 250 Reflow Temp ( C) Peak Temp 245 C The SMT modules of the HW/HC series are lead-free (Pb-free) and RoHS compliant and are both forward and backward compatible in a Pb-free and a SnPb soldering process. Failure to observe the instructions below may result in the failure of or cause damage to the modules and can adversely affect long-term reliability. Cooling Zone 4 C / second 200 * Min. Time Above 235 C 15 seconds 150 Heating Zone 1 C / second * Time Above 217 C 60 seconds 100 50 Pb-free Reflow Profile 0 Reflow Time (in seconds) Power Systems will comply with J-STD-020 Rev. C (Moisture/Reflow Sensitivity Classification for Nonhermetic Solid State Surface Mount Devices) for both Pb-free solder profiles and MSL classification procedures. This standard provides a recommended forced-air-convection reflow profile based on the volume and thickness of the package (table 4-2). The suggested Pb-free solder paste is Sn/Ag/Cu (SAC). The recommended linear reflow profile using Sn/Ag/Cu solder is shown in Figure. 26. Storage and Handling The recommended storage environment and handling procedures for moisture-sensitive surface mount packages is detailed in J-STD-033 Rev. A (Handling, Packing, Shipping and Use of Moisture/Reflow Sensitive Surface Mount Devices). Moisture barrier bags (MBB) with desiccant are required for MSL ratings of 2 or greater. These sealed packages should not be broken until time of use. Once the original package is broken, the floor life of the product at conditions of 30C and 60% relative humidity varies according to the MSL rating (see J-STD-033A). The shelf life for dry packed SMT packages will be a minimum of 12 months from the bag seal date, when LINEAGE POWER Figure 26. Recommended linear reflow profile using Sn/Ag/Cu solder. Solder Ball and Cleanliness Requirements The open frame (no case or potting) power module will meet the solder ball requirements per J-STD-001B. These requirements state that solder balls must neither be loose nor violate the power module minimum electrical spacing. The cleanliness designator of the open frame power module is C00 (per J specification). 18 Data Sheet October 5, 2009 HC006/010 Series DC-DC Power Module: 18-36Vdc Input; 3.3V & 5Vdc Output; 6.6A - 10A Output Current Ordering Information Please contact your Lineage Power Sales Representative for pricing, availability and optional features. Table 1. Device Codes Input Voltage Output Voltage Output Current 24 (18 - 36) Vdc 3.3 V 10A Remote On/Off Logic Negative 24 (18 - 36) Vdc 3.3 V 10A 24 (18 - 36) Vdc 5.0V 6.6A 24 (18 - 36) Vdc 5.0V 24 (18 - 36) Vdc 24 (18 - 36) Vdc 24 (18 - 36) Vdc Connector Type Product codes Comcodes SMT HC010A0F1-S 108975442 Negative SMT HC010A0F1-SZ 109100220 Negative SMT HC006A6A1-S 108975459 6.6A Negative SMT HC006A6A1-SZ 109100212 5.0V 6.6A Negative TH HC006A6A1 5.0V 6.6A Negative TH HC006A6A1Z CC109107100 5.0V 6.6A Negative TH HC006A6A61Z CC109140266 108994281 Table 2. Device Options Option Negative remote on/off logic Short Pins: 3.68 mm 0.25 mm (0.145 in 0.010 in) Suffix 1 6 Short Pins: 2.79 mm 0.25 mm (0.110 in 0.010 in) 8 Tape & Reel -R Surface mount connections -S RoHS Compliant -Z Asia-Pacific Headquarters Tel: +65 6593 7211 World Wide Headquarters Lineage Power Corporation 601 Shiloh Road, Plano, TX 75074, USA +1-800-526-7819 (Outside U.S.A.: +1-972-244-9428) www.lineagepower.com e-mail: techsupport1@lineagepower.com Europe, Middle-East and Africa Headquarters Tel: +49 898 780 672 80 India Headquarters Tel: +91 80 28411633 Lineage Power reserves the right to make changes to the product(s) or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Lineage Power DC-DC products are protected under various patents. Information on these patents is available at www.lineagepower.com/patents. (c) 2009 Lineage Power Corporation, (Plano, Texas) All International Rights Reserved. Document No: DS03-122 ver. 1.45 PDF name: hc006-010_series_ds.pdf