Specifications are subject to change without notice (01.12.99) 1
Plug Output Time range Supply:
24 VAC/DC & 115-230 VAC
Circular SPDT 0.1 s - 10 h S 103 156 924
Circular DPDT 0.1 s - 10 h S 103 166 924
Timers
• Time ranges: 0.1 s to 10 h
• 4 selectable functions: - Delay on operate
- Interval timer
- Interval timer, delay on release
- Recycler
• Easy time and function setting
• Knob-adjustable time setting
• Automatic and manual start functions
• Repeatability: ≤0.2%
• Output: 5 A SPDT or DPDT relay
• Plug-in module, S-housing
• LED-indication for relay and power supply ON
• 24 VAC/DC and 115 to 230 VAC power supply
• Cadmium-free contacts
• Timer in accordance with IEC 61812-1
Product Description
Multi-function, multi-voltage
timer with 6 selectable time
ranges from 0.1 s up to 10 h
for standard 11-pin circular
sockets. Used as a general
timer in industrial applica-
tions.
Ordering Key
Housing
Type/function
Output
Power supply
Type Selection
Time Specifications
Time ranges
Selectable by DIP-switch 0.1 - 1 s
1 - 10 s
0.1 - 1 m
1 - 10 m
0.1 - 1 h
1 - 10 h
Setting accuracy ≤5%
Repeatability ≤0.2%
Time variation
Within rated power supply ≤0.05%/V
and ambient temperature ≤0.2%/°C
Reset
Manual reset of time and/or relay Interconnect pins 5 & 2
Pulse duration ≥100 ms
Power supply interruption ≥200 ms
Output Specifications
Output S 103 156 924 SPDT relay
S 103 166 924 DPDT relay
Rated insulation voltage
250 VAC (rms) (cont./elect.)
Contact ratings (AgNi) µ (micro gap)
(IEC 60947-5-1/IEC 60337)
Resistive loads
AC 1
5 A/250 VAC
DC 1
5 A/24 VDC
Small inductive loads
AC 15
5 A/250 VAC
DC 13
2 A/24 VDC
Mechanical life ≥30 x 106operations
Electrical life AC 1 ≥105operations
(at max. load)
Operating frequency ≤7200 operations/h
Insulation voltage
Rated insulation voltage ≥2.0 kVAC (rms) (cont./elect.)
Rated impulse withstand volt. 4 kV (1.2/50 µs) (cont./elect.)
(IEC 60664)
Multi-function
Type S 103
S 103 156 924
Supply Specifications
Power supply AC connection
Overvoltage cat. III (IEC 60664)
Rated operational voltage
Through pins 2 & 10 115-230 VAC, -15 to +15%
50/60 Hz, -5/+5 Hz
or pins 2 & 10 24 VAC, -15 to +15%
(interconnect pins 6 & 10)
50/60 Hz, -5/+5 Hz
Voltage interruption ≤40 ms
Rated insulation voltage None
Rated impulse withstand volt. 4 kV (1.2/50 µs) (pin 2 & 10)
Power supply DC connection
Overvoltage cat. III (IEC 60664)
Rated operational voltage
Through pins 2 & 10 924 24 VDC, -15 to +15%
(interconnect pins 6 & 10) (pin 2 positive)
Voltage interruption ≤40 ms
Rated insulation voltage None
Rated impulse withstand volt. 1 kV (1.2/50 µs) (pin 2 & 6)
Rated operational current
AC supply 75 mA @ 230 VAC
40 mA @ 115 VAC
55 mA @ 24 VAC
DC supply 35 mA @ 24 VDC