C3P24D25C 2 SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE © 2010 TELEDYNE RELAYS
C3P24D25C\082010\Q3
Series C3P24D25C
Three-Phase Output to 25A 280 Vac
DC Control
Figure 5
SURGE CURRENT
100101
250
Number of Equal Amplitude Current Pulses at 60Hz
Max On-State Surge Current (Arms)
RECOMMENDED OUTPUT VOLTAGE PROTECTION
OUTPUT (LOAD) SPECIFICATION
Min Max Units
Operating Range 24 280 Vrms
Peak Voltage 600 Vpeak
Load Current Range .05 25 Arms
(See Figure 4)
Maximum Surge Current Rating (Non-Repetitive)
(See Figure 5) 250 A
On-State Voltage Drop 0.81 + (0.018 x I) V
Zero-Cross Window (Typical) ±12 V
O -State Leakage Current (60 Hz) 1 mA
Turn-On Time 8.3 ms
Turn-O Time 8.3 ms
O -State dv/dt 500 V/μs
Operating Frequency Range 47 2000(*) Hz
I2t for Match Fusing (<8.3 ms) 260 A2S
Thermal Resistance (One phase) Rthj/c
Junction-Case 0.85 ºC/W
ENVIRONMENTAL SPECIFICATION
Min Max Units
Operating Temperature -40 100 ºC
Storage Temperature -55 100 ºC
Input-Ouput Isolation 2500 Vi
Output-Case Isolation 2500 Vi
Rated Impulse Voltage 2500 V
NOTES
(*) Relay built with back-to-back thyristors and high performance
optocouplers. Relays have been tested at Teledyne Relays with frequencies
higher than 2000 Hz on a resistive load.
For other loads the user will have to check functionality in nal application.
THERMAL CHARACTERISTICS
Figure 4
0 2 4 6 8 10 12 14 16 18 20 22 240
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
95
0
0 10 20 30 40 50 60 70 80 90 1000
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
95
0
4C/W
2C/W
1.5C/W
1C/W
0.75C/W
3 Phases
2 Phases
1Phase
Load Current (A)
Power Dissipation (W)
An external Voltage Dependent Resistor (VDR) is recommended in case of
voltage spike.
AC
AC
+
-
Rc
Uc
Ic
Load
Ph
voltage
protection
by VDR on
the PCB
Figure 3
DETECTION/
CONTROL
CIRCUIT
DETECTION/
CONTROL
CIRCUIT
VDC
Input
+
–
A1
POLE A
AC
A2
B1
B2
POLE B
AC
DETECTION/
CONTROL
CIRCUIT
C1
POLE C
AC
C2
OPTO
ISOLATED
CONTROL
BLOCK DIAGRAM
NOTES
1. Electrical speci cations at 25 ºC unless otherwise speci ed.
2. See gure 6 for output protection recommendation
3. For additional/custom options, contact factory
Figure 6