Your Contact for Relays
NEW!
*GRAYHILL SSR’s.
*CLASS 6 660 VOLT.
SPST-N.O.
* DUAL OUTPUT
DPST-N.O.
*CLASS 6 CLEAR
SAFETY COVER.
PRODUCT MARKETING BULLETIN 2000 SSR
SOLID STATE RELAYS
CLASS 70S2 MINIATURE SSR’s
CLASS 6 SSR’s
CLASS 70S2 MINIATURE SSR’s
(FORMERLY GRAYHILL)
2.5 Amp to 25 Amp Outputs
CLASS 6 SSR’s
2.5 Amp to 125 Amp Outputs
SOLID STATE RELAYS
2.5 A
3 A
4 A
6 A
6 A
6 A
6 A
10 A
12 A
12 A
25 A
MICRO CUBE RELAY, ONLY 0.500” HIGH
SINGLE IN - LINE PACKAGE, USES ONLY 0.680 SQ. INCHES BOARD AREA
MINI CUBE RELAY, PC MOUNT
USE HEAT SINK OR PANEL MOUNT
USE HEAT SINK OR PANEL MOUNT
MINI PUCK RELAY, PANEL MOUNT, FIT/FUNCTION
REPLACEMENTS FOR LARGER HOCKEY PUCK STYLES, TAP TERMINALS
MINI PUCK RELAY, PANEL MOUNT, FIT/FUNCTION
REPLACEMENTS FOR LARGER HOCKEY PUCK STYLES, SCREW TERMINALS
USE HEAT SINK OR PANEL MOUNT
MINI PUCK RELAY, PANEL MOUNT, FIT/FUNCTION
REPLACEMENTS FOR LARGER HOCKEY PUCK STYLES, TAP TERMINALS
MINI PUCK RELAY, PANEL MOUNT, FIT/FUNCTION
REPLACEMENTS FOR LARGER HOCKEY PUCK STYLES, SCREW TERMINALS
MINI PUCK RELAY, PANEL MOUNT, FIT/FUNCTION
REPLACEMENTS FOR LARGER HOCKEY PUCK STYLES, SCREW TERMINALS
H
V
F
L
M
M
N
S
S
N
S
V
F
SINGLE IN - LINE PACKAGE, USES ONLY 0.680 SQ . INCHES BOARD AREA
MINI CUBE RELA Y, PC MOUNT
MINI PUCK RELA Y, P ANEL MOUNT, FIT/FUNCTION
REPLACEMENTS FOR LARGER HOCKEY PUCK STYLES, TAP TERMINALS
MINI PUCK RELA Y, P ANEL MOUNT, FIT/FUNCTION
REPLACEMENTS FOR LARGER HOCKEY PUCK STYLES, SCREW TERMINALS
3-15 or 9-30 VDC
3-15 or 9-30 VDC
3-15 VDC
3-15 VDC
3 A
3 A
5 A
5 A
DC INPUT-AC OUTPUT
DC INPUT-DC OUTPUT
MAX. LOAD CURRENT CONTROL VOLTAGE NOMINAL LOAD
VOLTAGE DESCRIPTION AND FEA TURES STYLE
24, 120 or 240 VAC
24, 120 or 240 VAC
24, 120 or 240 VAC
120 or 240 VAC
120 or 240 VAC
120 or 240 VAC
120 or 240 VAC
120 or 240 VAC
120 or 240 VAC
120 or 240 VAC
N
S
MAX. LOAD CURRENT CONTROL VOLTAGE NOMINAL LOAD
VOLTAGE DESCRIPTION AND FEA TURES STYLE
3 to 60 VDC
3 to 60 VDC
3 to 60 VDC
3 to 60 VDC
EXCELLENT TRANSIENT PROTECTION
HIGH SURGE CURRENT CAPABILITY
OPTICALLY ISOLATED
HIGH BLOCKING VOLTAGE
EXTREMELY LONG LIFE
MINIATURE BUT MIGHTY; UP TO 25 AMP SWITCHING
*
*
*
*
*
*
BENEFITS -
CLASS 70S2 SSR’s
BENEFITS -
CLASS 70S2 SSR’s
3-30 or 6-30 VDC
3-32 or 6-32 VDC
3-30 or 6-30 VDC
3-30 or 6-30 VDC
3-30 or 6-30 VDC
3-30 or 6-30 VDC
3-30 or 6-30 VDC
3-30 or 6-30 VDC
3-30 or 6-30 VDC
3-30 or 6-30 VDC
3-30 VDC
Optically Isolated Solid State Relay
Control Voltage
01 = 2 - 15 VDC, DC/DC Relays
02 = 9 - 30 VDC, DC/DC Relays
03 = 3 - 30 VDC, 25 A mini - puck
04 = 3 - 30 VDC, DC/AC Relays
05 = 6 - 30 VDC, DC/AC Relays
Nominal Voltage
A = 3-60 VDC B = 120 VAC
C = 240 VAC D = 24 VAC
Max Current Rating
02 = 2.5 A 04 = 4 A 06 = 6 A 12 = 12 A
03 = 3 A 05 = 5 A 10 = 10A 25 = 25 A
Package Style
F, H, L, M, N, S or V. See selection below.
PART NUMBER EXPLANATION 70S2- 04- D- 03- V
3-32 VDC 6-32 VDC
5 VDC 5 VDC
1.0 -19.0 mA 1.0 -6.0 mA
2000 6000
3Amps
24 V=10-50 V,120 V=24-140V, 240 V=24-280 V
65 mA
24 V=4 mA, 120V=6 mA, 240 V=6 mA
1.5 V Peak Max.
3000 V/ microsecond.
25 Hz to 70 Hz
60 Amps Peak Max.(@ 25˚C)
24 V= 200 V, 120 V= 400 V, 240 V= 600 V
8.3 mS Maximum.
8.3 mS Maximum.
Normally Open
3000 V rms. Min.
109
-40°C to +100°C
-40°C to +125°C
19 g.
FIGURE 1 CHART INDICATES CONTINUOUS CURRENT TO LIMIT
THE JUNCTION TEMPERATURES TO 100˚ C. INFORMATION IS
BASED ON STEADY STATE HEAT TRANSFER IN A 2 CUBIC FOOT
SEALED ENCLOSURE.
FIGURE 2 CHART INFORMATION IS BASED ON A SUPPLY
FREQUENCY OF 60 HERTZ SINUSOIDAL AND A RESISTIVE OR
INDUCTIVE LOAD. APPLICATION OF MAXIMUM SURGE CURRENT
MAY NOT BE REPEATED UNTIL THE RELAY TEMPERATURE HAS
RETURNED TO ITS STEADY STATE VALUE.
FIGURE 1: Maximum Continuous Current VS.
Ambient Temperature Figure 2: Maximum Peak Surge Current vs.
Surge Duration
3
2
1
AMBIENT TEMPERATURE (C˚)
10
6
4
3
1
1
300
200
100
80
60
40
30
20
1.700 (43.18)
0.235 ±0.020
5.97 ±0.51
1.000
(25.4)
0.900 (22.86)
1.100 (27.94) OBSERVE POLARITY
ON DC OUTPUT STYLES
0.400 (10.16)
0.300 (7.62)
0.400
(10.16)
0.040 / 0.042 DIA.
(Ø 1.04) TYP. 0.1000
(2.54)
INPUT CHARACTERISTICS
Input voltage range:
Max.Reverse Control voltage:
Input current:
Average Input Impedance:
OUTPUT CHARACTERISTICS
Max. Load Current :
Load Voltage Range (VAC):
Minimum Load Current IT MIN (RMS) to maintain “ON”:
Maximum Off State Leakage current ID (RMS):
Maximum On-State Voltage VT drop:
Maximum off-state dv/dt:
Operating Frequency Range:
One Cycle surge current:
Minimum Peak Blocking voltage:
Turn - On Time (60Hz):
Turn - Off Time (60Hz):
MISCELLANEOUS CHARACTERISTICS
Output configuration:
Dielectric Strength VISO (Input-Output Isolation):
Insulation Resistance :
Operating temperature Range:
Storage temperature Range:
Weight:
1 2 3 4 6 10 20 40 60 100 1000
-40˚ -20˚ 0˚ 20˚ 40˚ 60˚ -80˚ 100˚
SURGE CURRENT DURATION-FULL CYCLES
“ V ” STYLE
STYLE “ V ”
* SINGLE IN LINE PACKAGE RELAY
* OPTICALLY ISOLATED
* PC MOUNT FOR LOADS UP TO 3 AMPS
* MINIMAL BOARD SPACE REQUIRED
* TUV RHEINLAND CERTIFIED TO
EN60947 - 5 - 1 SAFETY REQUIREMENTS
( 24VAC, 120 VAC, 240 VAC STYLES.)
* LIFETIME WARRANTY
FEATURES
OUTLINE DIMENSIONS
Dimensions Shown in Inch and (Millimeter).
GENERAL SPECIFICATIONS
LOAD CURRENT (AMPS )
N”&“S”STYLE
OUTLINE DIMENSIONS
Dimensions shown in Inch and (Millimeter).
(1)
(2)
(4) -
(3) +
AC
SUPPLY
LOAD
DC
INPUT
-
+
NOTE:
STYLE S IS NOT INTENDED
FOR PC BOARD MOUNTING.
CONSULT FACTORY
(1)
(2)
(4)
(3)
2.200 (55.88)
1.870 (47.50)
1.200 (30.48)
0.500
(12.7) 1.000
(25.4)
0.900 (22.86)
2 TERMINALS
0.187 (4.75)
2 TERMINALS
0.187 (4.75) 2 TERMINALS
0.250 (6.35)
0.176
(4.47)
0.400
(10.16)
(1)
(2)
(4)
(3)
2.200 (55.88)
1.870 (47.50)
1.200 (30.48)
0.600
(15.24) 1.000
(25.4)
0.750
(19.05)
0.176
(4.47)
0.400
(10.16)
OBSERVE POLARITY
ON DC OUTPUT STYLES
STYLE NSTYLE S
0.230 MIN
(5.842)
0.864
(21.95)MAX.
0.270 MIN
(6.858)
0.864
(21.95)MAX.
(4)6-32 SCREWS
AND WASHERS
PROVIDED
0.980
(24.89)
MAXIMUM SCREW TORQUE = 9 IN - LBS
FEATURES
* MINI PUCK SOLID RELAYS
* OPTICALLY ISOLATED
* PANEL MOUNT; UP TO 25 AMP LOADS
* MOUNTS ON HOCKEY PUCK RELAY
CENTERS, YET NEEDS 1/2 THE SPACE
* SCREW TERMINALS OR PUSH - ON QC
TERMIN ALS
* LIFETIME WARRANTY
FIGURE 1 CHART INDICATES CONTINUOUS CURRENT TO LIMIT
THE JUNCTION TEMPERATURES TO 100˚ C. INFORMATION IS
BASED ON STEADY STATE HEAT TRANSFER IN A 2 CUBIC FOOT
SEALED ENCLOSURE.
FIGURE 2 CHART INFORMATION IS BASED ON A SUPPLY
FREQUENCY OF 60 HERTZ SINUSOIDAL AND A RESISTIVE OR
INDUCTIVE LOAD. APPLICATION OF MAXIMUM SURGE CURRENT
MAY NOT BE REPEATED UNTIL THE RELAY TEMPERATURE HAS
RETURNED TO ITS STEADY STATE VALUE.
F
IGURE 1: Maximum Continuous Current VS.
Ambient Temperature
Figure
2: Maximum Peak Surge Current vs.
Surge Duration
AMBIENT TEMPERATURE (C˚)
10
6
4
3
1
1
300
200
100
80
60
40
30
20
1 2 3 4 6 10 20 40 60 100 1000
-40˚ -20˚ 0˚ 20˚ 40˚ 60˚ -80˚ 100˚
SURGE CURRENT DURATION-FULL CYCLES
“ V ” & “S” STYLE
INPUT CHARACTERISTICS
Input Voltage Range:
Max. Reverse Control Voltage:
Input Current:
Average Input Impedance @ 24 VDC Typ.:
OUTPUT CHARACTERISTICS
Max. Load Current :
Load Voltage Range (VAC):
Minimum Load Current IT MIN (RMS) to Maintain “ON”:
Maximum Off State Leakage Current ID(RMS):
Maximum On-State Voltage VTDrop:
Maximum Off-State dv/dt:
Operating Frequency Range:
One Cycle Surge Current:
Minimum Peak Blocking Voltage:
Turn - On Time (60Hz):
MTurn - Off Time (60Hz):S
MISCELLANEOUS CHARACTERISTICS
Output Configuration:
Dielectric Strength VISO (Input-Output Isolation):
Insulation Resistance:
Operating Temperature Range:
Storage Temperature Range:
Weight:
3-30 VDC 6-30 VDC
5 VDC 5 VDC
7.0 -16.0 mA 6.0 -10.0 mA
1777 2750
6 , 12 & 25 Amps
120 = 24-140 VAC, 240= 24-280 VAC
6 Amps = 75 mA, 12 & 25 Amps = 100 mA
120 V =6 mA, 240 V =6 mA
1.6 V Peak Max.
3000 V/ microsecond typical.
25 Hz to 70 Hz
60, 150 & 300 Amps Peak Max.
120 = 400 V, 240 = 600 V
8.3 mS Maximum.
8.3 mS Maximum.
Normally Open.
3000 V rms. Min.
109
-40°C to +100°C
-40°C to +125°C
35 g. Style N, 56 g. Style S Appox.
GENERAL SPECIFICATIONS
25
20
15
10
5
STYLE S, 25A
STYLE N & S, 12A
STYLE N & S, 6A
25 AMP
12 AMP
6 AMP
LOAD CURRENT (AMPS )
F
IGURE 1: Maximum Continuous Current VS.
Ambient Temperature
Figure
2: Maximum Peak Surge Current vs.
Surge Duration
AMBIENT TEMPERATURE (C˚)
10
6
4
3
1
1
300
200
100
80
60
40
30
20
1 2 3 4 6 10 20 40 60 100 1000
-40˚ -20˚ 0˚ 20˚ 40˚ 60˚ -80˚ 100˚
SURGE CURRENT DURATION-FULL CYCLES
“ F ” & “ M ” STYLE
GENERAL SPECIFICATIONS
STYLE M, 10A
STYLE M, 6A
STYLE F, 4A
10 AMP
4 & 6 AMP
14
12
10
8
6
4
2
FIGURE 1 CHART INDICATES CONTINUOUS CURRENT TO LIMIT
THE JUNCTION TEMPERATURES TO 100˚ C. INFORMATION IS
BASED ON THE USE OF A 12” X 12” X 1/8” ALUMINUM HEAT SINK
WITH SILICON GREASE IN A 2 CUBIC FOOT SEALED ENCLOSURE.
FIGURE 2 CHART INFORMATION IS BASED ON A SUPPLY FREQUENCY
OF 60 HERTZ SINUSOIDAL AND A RESISTIVE OR INDUCTIVE LOAD.
APPLICATION OF MAXIMUM SURGE CURRENT MAY NOT BE REPEATED
UNTIL THE RELAY TEMPERATURE HAS RETURNED TO ITS STEADY
STATE VALUE.
INPUT CHARACTERISTICS
Input Voltage Range:
Max Reverse Control Voltage:
Input Current:
Average Input Impedance @ 24 VDC Typ.:
OUTPUT CHARACTERISTICS
Max. Load Current :
Load Voltage Range (VAC)
Minimum Load Current IT MIN (RMS) to Maintain “ON”:
Maximum Off State Leakage Current ID(RMS):
Maximum On-State Voltage VTDrop:
Maximum Off-State dv/dt:
Operating Frequency Range:
One Cycle Surge Current:
Minimum Peak Blocking Voltage:
Turn - On Time (60Hz):
MTurn - Off Time (60Hz):S
MISCELLANEOUS CHARACTERISTICS
Output Configuration:
Dielectric Strength VISO (Input-Output Isolation):
Insulation Resistance :
Operating Temperature Range:
Storage Temperature Range:
Weight:
3-30 VDC 6-30 VDC
5 VDC 5 VDC
7.0 -16.0 mA 6.0 -10.0 mA
1777 2750
4, 6 & 10 Amps
24-140 VAC, 24-280 VAC
75 mA
6 mA
1.5 V Peak Max.
3000 V/ microsecond typical.
25 Hz to 70 Hz
4 = 60, 6 = 60, 10 =110 Amps Peak Max.
120=400 V, 240=600 V
8.3 mS Maximum.
8.3 mS Maximum.
Normally Open.
3000 V rms. Min.
109
-40°C to +100°C
-40°C to +125°C
30 g. Style F, 52 g. Style M Appox.
LOAD CURRENT (AMPS )
H”&“L”STYLE
OUTLINE DIMENSIONS
Dimensions shown in Inch and (Millimeter).
(1)
(2)
(4)
(3)
0.600
(15.24) 1.000
(25.4)
4 SQ. PINS
0.025 (0.64) 0.300 MIN.
(7.62)
0.400
(10.16)
STYLE HSTYLE L
0.516
(13.1) MAX.
0.185 MIN.
(4.70)
1.200 (30.48) 2.200 (55.88)
0.520
(13.21) MAX.
(1)
(2)
(4) -
(3) +
AC
SUPPLY
LOAD
DC
INPUT
-
+
OBSERVE POLARITY
ON DC OUTPUT STYLES
0.300
(7.62)
FEATURES
* MICRO CUBE SOLID STATE RELAY
* OPTICALLY ISOLATED
* PC MOUNT ONLY 0.5” ABOVE BOARD
* MINIMAL BOARD SPACE REQUIRED
* LIFETIME WARRANTY
0.185 MIN.
(4.74)
0.450 MIN.
(11.43)
0.200
(5.08)
F
IGURE
1:
Maximum Continuous Current
VS
.
Ambient Temperature
Figure
2: Maximum Peak Surge Current vs.
Surge Duration
AMBIENT TEMPERATURE (C˚)
10
6
4
3
1
1
300
200
100
80
60
40
30
20
1 2 3 4 6 10 20 40 60 100 1000
-40˚ -20˚ 0˚ 20˚ 40˚ 60˚ -80˚ 100˚
SURGE CURRENT DURATION-FULL CYCLES
“ H ” & “ L ” STYLE
GENERAL SPECIFICATIONS
STYLE L, 6A
STYLE H, 2.5A 2.5 & 6 AMP
INPUT CHARACTERISTICS
Input Voltage Range:
Max Reverse Control Voltage:
Input current:
Average Input Impedance @ 24 VDC Typ.:
OUTPUT CHARACTERISTICS
Max. Load Current :
Load Voltage Range (VAC):
Minimum Load Current IT MIN (RMS) to maintain “ON”:
Maximum Off State Leakage current ID (RMS):
Maximum On-State Voltage VT drop:
Maximum off-state dv/dt:
Operating Frequency Range:
One Cycle surge current:
Minimum Peak Blocking voltage:
Turn - On Time (60Hz):
Turn - Off Time (60Hz):
MISCELLANEOUS CHARACTERISTICS
Output configuration:
Dielectric Strength VISO (Input-Output Isolation):
Insulation Resistance :
Operating Temperature Range:
Storage Temperature Range:
Weight:
FIGURE 1 CHART INDICATES CONTINUOUS CURRENT TO LIMIT THE
JUNCTION TEMPERATURES T O 100˚ C. INFORMATION IS B ASED ON THE
USE OF A 12” X 12” X 1/8” ALUMINUM HEAT SINK WITH SILICON GREASE
IN A 2 CUBIC FOOT SEALED ENCLOSURE.
FIGURE 2 CHART INFORMATION IS BASED ON A SUPPLY FREQUENCY
OF 60 HERTZ SINUSOIDAL AND A RESISTIVE OR INDUCTIVE LOAD.
APPLICATION OF MAXIMUM SURGE CURRENT MAY NOT BE REPEATED
UNTIL THE RELAY TEMPERATURE HAS RETURNED TO ITS STEADY
STATE VALUE.
3-32 VDC 6-30 VDC
5 VDC 5 VDC
1.0 -18.0 mA 1.0 -6.0 mA
2777 6000
2.5 & 6.0 Amps
24 V=10-50 V, 120 V=24-140 V, 240 V=24-280 V
75 mA
24V= 4 mA120 V=6 mA, 240 V=6 mA
1.5 V Peak Max.
3000 V/microsecond typical.
25 Hz to 70 Hz
60 Peak Max.
24 V= 200 V, 120 V= 400 V, 240 V= 600 V
8.3 mS Maximum.
8.3 mS Maximum.
Normally Open.
2500 V rms. Min.
10
9
-40°C to +100°C
-40°C to +125°C
20 g. Style H, 22 g. Style L Appox.
8
7
6
5
4
3
2
1
LOAD CURRENT (AMPS )
10 - 50 AC
10 - 50 AC
24 - 140 AC
24 - 140 AC
24 - 280 AC
24 - 280 AC
24 - 140 AC
24 - 140 AC
24 - 280 AC
24 - 280 AC
24 - 140 AC
24 - 140 AC
24 - 140 AC
24 - 140 AC
24 - 280 AC
24 - 280 AC
24 - 280 AC
24 - 280 AC
3-32 VDC
6-32 VDC
3-32 VDC
6-32 VDC
3-32 VDC
6-32 VDC
3-30 VDC
6-30 VDC
3-30 VDC
6-30 VDC
3-30 VDC
6-30 VDC
3-30 VDC
6-30 VDC
3-30 VDC
6-30 VDC
3-30 VDC
6-30 VDC
MAX.
VOLTAGE
50 VAC
50 VAC
140 VAC
140 VAC
280 VAC
280 VAC
140 VAC
140 VAC
280 VAC
280 VAC
140 VAC
140 VAC
140 VAC
140 VAC
280 VAC
280 VAC
280 VAC
280 VAC
3 AMPS
3 AMPS
3 AMPS
3 AMPS
3 AMPS
3 AMPS
6 AMPS
6 AMPS
6 AMPS
6 AMPS
6 AMPS
6 AMPS
10 AMPS
10 AMPS
6 AMPS
6 AMPS
10 AMPS
10 AMPS
NOMINAL
VOLTAGE RANGE MAX. CURRENT
RATING
CONTROL
VOLTAGE RANGE MIN
DROP OUT
1 VDC
1 VDC
1 VDC
1 VDC
1 VDC
1 VDC
1 VDC
1 VDC
1 VDC
1 VDC
1 VDC
1 VDC
1 VDC
1 VDC
1 VDC
1 VDC
1 VDC
1 VDC
STYLE TYPE
OUTPUT (Over Operating Temperature Range)
INPUT (Over Operating Temperature Range)
DC CONTROLLED
AC OUTPUT
70S2-04-D-03-V
70S2-05-D-03-V
70S2-04-B-03-V
70S2-05-B-03-V
70S2-04-C-03-V
70S2-05-C-03-V
70S2-04-B-06-L
70S2-05-B-06-L
70S2-04-C-06-L
70S2-05-C-06-L
V
V
V
V
V
V
L
L
L
L
MAX.
PULL - IN
3 VDC
6 VDC
3 VDC
6 VDC
3 VDC
6 VDC
3 VDC
6 VDC
3 VDC
6 VDC
3 VDC
6 VDC
3 VDC
6 VDC
3 VDC
6 VDC
3 VDC
6 VDC
70S2-04-D-02-H
70S2-05-D-02-H
70S2-04-B-02-H
70S2-05-B-02-H
70S2-04-C-02-H
70S2-05-C-02-H
70S2-04-B-04-F
70S2-05-B-04-F
70S2-04-C-04-F
70S2-05-C-04-F
70S2-04-B-06-M
70S2-05-B-06-M
70S2-04-B-10-M
70S2-05-B-10-M
70S2-04-C-06-M
70S2-05-C-06-M
70S2-04-C-10-M
70S2-05-C-10-M
70S2-04-B-06-S
70S2-05-B-06-S
70S2-04-B-12-S
70S2-05-B-12-S
70S2-03-B-25-S
70S2-04-C-06-S
70S2-05-C-06-S
70S2-04-C-12-S
70S2-05-C-12-S
70S2-03-C-25-S
3-30 VDC
6-30 VDC
3-30 VDC
6-30 VDC
3-30 VDC
6-30 VDC
3 VDC
6 VDC
3 VDC
6 VDC
3 VDC
6 VDC
1 VDC
1 VDC
1 VDC
1 VDC
1 VDC
1 VDC
10 - 50 AC
10 - 50 AC
24 - 140 AC
24 - 140 AC
24 - 280 AC
24 - 280 AC
50 VAC
50 VAC
140 VAC
140 VAC
280 VAC
280 VAC
2.5 AMPS
2.5 AMPS
2.5 AMPS
2.5 AMPS
2.5 AMPS
2.5 AMPS
H
H
H
H
H
H
3-30 VDC
6-30 VDC
3-30 VDC
6-30 VDC
3 VDC
6 VDC
3 VDC
6 VDC
1 VDC
1 VDC
1 VDC
1 VDC
24 - 140 AC
24 - 140 AC
24 - 280 AC
24 - 280 AC
140 VAC
140 VAC
280 VAC
280 VAC
4 AMPS
4 AMPS
4 AMPS
4 AMPS
70S2-04-B-06-N
70S2-05-B-06-N
70S2-04-B-12-N
70S2-05-B-12-N
70S2-04-C-06-N
70S2-05-C-06-N
70S2-04-C-12-N
70S2-05-C-12-N
3-30 VDC
6-30 VDC
3-30 VDC
6-30 VDC
3-30 VDC
6-30 VDC
3-30 VDC
6-30 VDC
3 VDC
6 VDC
3 VDC
6 VDC
3 VDC
6 VDC
3 VDC
6 VDC
3-30 VDC
6-30 VDC
3-30 VDC
6-30 VDC
3-30 VDC
3-30 VDC
6-30 VDC
3-30 VDC
6-30 VDC
3-30 VDC
3 VDC
6 VDC
3 VDC
6 VDC
3 VDC
3 VDC
6 VDC
3 VDC
6 VDC
3 VDC
1 VDC
1 VDC
1 VDC
1 VDC
1 VDC
1 VDC
1 VDC
1 VDC
24 - 140 AC
24 - 140 AC
24 - 140 AC
24 - 140 AC
24 - 280 AC
24 - 280 AC
24 - 280 AC
24 - 280 AC
140 VAC
140 VAC
140 VAC
140 VAC
280 VAC
280 VAC
280 VAC
280 VAC
1 VDC
1 VDC
1 VDC
1 VDC
1 VDC
1 VDC
1 VDC
1 VDC
1 VDC
1 VDC
24 - 140 AC
24 - 140 AC
24 - 140 AC
24 - 140 AC
24 - 140 AC
24 - 280 AC
24 - 280 AC
24 - 280 AC
24 - 280 AC
24 - 280 AC
140 VAC
140 VAC
140 VAC
140 VAC
140 VAC
280 VAC
280 VAC
280 VAC
280 VAC
280 VAC
6 AMPS
6 AMPS
12 AMPS
12 AMPS
25 AMPS
6 AMPS
6 AMPS
12 AMPS
12 AMPS
25 AMPS
6 AMPS
6 AMPS
12 AMPS
12 AMPS
6 AMPS
6 AMPS
12 AMPS
12 AMPS
F
F
F
F
M
M
M
M
M
M
M
M
N
N
N
N
N
N
N
N
S
S
S
S
S
S
S
S
S
S
MAX.
VOLTAGE
NOMINAL
VOLTAGE RANGE MAX. CURRENT
RATING
CONTROL
VOLTAGE RANGE MIN
DROP OUT STYLE TYPE
MAX.
PULL - IN
3-15 VDC
9-30 VDC
3-15 VDC
9-30 VDC
3-15 VDC
3-15VDC
9-30 VDC
3 VDC
9 VDC
3 VDC
9 VDC
3 VDC
3 VDC
9 VDC
1 VDC
1 VDC
1 VDC
1 VDC
1 VDC
1 VDC
1 VDC
3 - 60 VDC
3 - 60 VDC
3 - 60 VDC
3 - 60 VDC
3 - 60 VDC
3 - 60 VDC
3 - 60 VDC
60 VDC
60 VDC
60 VDC
60 VDC
60 VDC
60 VDC
60 VDC
3 AMPS
3 AMPS
3 AMPS
3 AMPS
5 AMPS
5 AMPS
5 AMPS
V
V
F
F
N
S
S
70S2-01-A-03-V
70S2-02-A-03-V
70S2-01-A-03-F
70S2-02-A-03-F
70S2-01-A-05-N
70S2-01-A-05-S
70S2-02-A-05-S
Av ailable from Your Local Magnecraft & Struthers- Dunn Distributors.
PART NUMBERS
FORMERLY GRAYHILL
20
10
30
40
45
60
Mounted on Heat Sink with
C/W thermalresistance.
FreeAir Mounting
6" x 6"x 1/8"
Aluminum Plate
010 20 30 40 50 60 70 80
-90
-95
-100
-105
-110
0
20 40 60 80 100
MAX. AMBIENT TEMPERATURE (˚C)
50
90
70
80
40
30
20
0
10
75 Amp Styles
MAX. AMBIENT TEMPERATURE (˚C)
0
3
1
2
20 40 60 80 100
MAX. AMBIENT TEMPERATURE (˚C)
Free Air Mounting
2.5 Amp Style
20 40 60 80 100
0
10
14
16
8
6
4
2
12
Free Air Mounting
Heat Sink
withC/W
thermal
resistance.
10 Amp Styles
20 40 60 80 100
25
40
30
35
20
15
10
5
0
Free Air Mounting
25 Amp Styles
6" x 6"x 1/8"Aluminum Plate 6" x 6"x 1/8"Aluminum Plate
6" x 6" x 1/8"
Aluminum
Plate
MAX. AMBIENT TEMPERATURE (˚C)
MAX. AMBIENT TEMPERATURE (˚C)
THERMAL DERATING CURVE & LOAD CHARACTERISTICS
All current ratings in the following pages are based on use of suitable thermally conductive compound (e.g. silicone grease
between the SSR mounting base and mounting surface of suitable heat sink).
40 & 50 Amp Styles
Mounted on Heat Sink with
1˚C/W thermal resistance.
(Sink to Ambient)
75
1.5˚C/W
0.1C/W
0.14˚C/W (50A) 6" x 6"x 1/8"
Aluminum Plate
10 20 30 40 50 60 70 80 90
180
160
140
120
100
80
60
40
20
MAX. AMBIENT TEMPERATURE (˚C)
90 & 125 Amp Styles
Heat sink
0.14˚C/W Fan output
70 CFM
With Fan
Without Fan
125 Amp
90 Amp
SOLID STATE RELAY
C US
On selected Models.
BENEFITS-
CLASS 6 SSR’s
BENEFITS
CLASS 6 SSR’s
*
*
*
*
L.E.D. STATUS LAMP
CLEAR SAFETY COVER
SINGLE AND DUAL OUTPUTS
UPTO 660 VOLT OUTPUTS
-
LOAD CURRENT (AMPS RMS)
LOAD CURRENT (AMPS RMS)
LOAD CURRENT (AMPS RMS) LOAD CURRENT (AMPS RMS)
LOAD CURRENT (AMPS RMS)
LOAD CURRENT (AMPS RMS)
MAX. ALLOW ABLE TEMPERA TURE
OUTPUT CHARACTERISTICS
INPUT CHARACTERISTICS
Input Voltage Range:
Power Indicator:
Reverse Polarity Protected:
Input Filtered for Transients less than One Millisecond:
Input Current:
Input Impedence:
Max. Load Current :
Load Voltage Range (VAC)
Maximum Output Voltage (VAC):
Minimum Load Current IT MIN (RMS) to Maintain “ON”
Maximum Off State Leakage Current ID(RMS):
Maximum On-State Voltage Drop VT (RMS):
Maximum Off-State dv/dt:
Turn - On Time (60Hz):
Turn - Off Time (60Hz):
Output Configuration:
Dielectric Strength VISO (Input-Output Isolation):
Insulation Resistance RISO @ 500VDC:
Operating Temperature Range:
Storage Temperature Range:
Life:
Weight:
MISCELLANEOUS CHARACTERISTICS
3-32 VDC, 90 - 280 VAC and 3.5 to 32 VDC (DDX)
L.E.D. Indicator.
Yes: DC Input with AC output styles only.
Yes
8mA@ 3VDC, 25mA @32 VDC.
ASX-13K Min., DSX-1.5K Min., DTX and DDX-1K Min.,
2.5 Amps to 125 Amps
W62 Models: 24-240 VAC, W64 Models: 48-480 VAC,W66 Models: 48-600 VAC
W62: 280 VAC, W64: 560 VAC, W66: 660
Up to 10 Amp Models: 50 mA, 25 Amp Models: 120 mA,
40 to 75 Amp Models: 250mA ,90 to 125 Amp, 500 mA, DDX 20 mA.
10 mA Max.
Up to 50 Amp Models: 1.6 V, 75 to 125 Amp Models: 1.8 V, DDX 2.83 V.
Up to 500 V/usec.
ASX, DSX & DTX, 1/2 Cycle, (DDX) 600 uS Max.
ASX, DSX & DTX, 1/2 Cycle, (DDX) 2.6 mS Max.
(ASX, DSX & DDX) SPST-NO. (DTX) DPST-NO.
4000 VAC, DDX Models 2500 VAC.
1010
-40°C to +80°C
-40°C to +100°C
Greater than 100 Million Operations
2.5 to 50 Amp Models: 4 oz. (110 g) 75 Amp to 125 Amp Models: 6.8 oz.
(192 g), 12 Amps, 25 Amps & 40 Amps, DDX Models: 4.76 oz. (135 g).
CONSULT FACTORY FOR SPECIALS
UP T O 40 AMP
INPUT OUTPUT
3.5 mm
ABOVE 40 AMP
INPUT & OUTPUT SCREW SIZE
(Shown in Millimeters)
6 mm
3.5 mm
4 mm
0.187”
(4.74) QC
0.250”
(6.35) QC
RED LED
LAMP
2.250
(57.2)
RED
L.E.D.
1.750
(44.5)
0.996 max. (25.3) for 75 & 50-40 Amp
DDX models & for 75 to 125 Amps DSX & ASX models.
0.800 max (20.32) for models ASX, DSX & DTX models
up to 50 Amps & DDX 12 Amps models.
INPUT OUTPUT
RED LED
LAMP
SPST-N.O.
2.665 (67.691)
1.945
(49.403)
0.475
(12.065)
SAFETY COVER
2.250
(57.2)
RED
L.E.D.
1.750
(44.5)
0.800 max (20.32)
INPUT OUTPUT
DPST-N.O.
GENERAL SPECIFICATIONS
DPS
T
-
N
.
O
.
SPS
T
-N.O.
OUTLINE DIMENSIONS
Dimensions Shown in Inch and (Millimeter).
LIFETIME WARRANTY
0.800
(20.32)
24-240 VAC
24-240 VAC
24-240 VAC
24-240 VAC
24-240 VAC
24-240 VAC
48-480 VAC
48-480 VAC
48-480 VAC
48-480 VAC
48-480 VAC
3-32 VDC
3-32 VDC
3-32 VDC
3-32 VDC
3-32 VDC
3-32 VDC
3-32 VDC
3-32 VDC
3-32 VDC
3-32 VDC
3-32 VDC
MAX.
VOLTAGE
280 VAC
280 VAC
280 VAC
280 VAC
280 VAC
280 VAC
560 VAC
560 VAC
560 VAC
560 VAC
560 VAC
2.5 AMPS
10 AMPS
25 AMPS
40 AMPS
50 AMPS
75 AMPS
10 AMPS
25 AMPS
40 AMPS
50 AMPS
75 AMPS
IDECCRYDOM POTTER &
BRUMFIELD
D2402
D2410
D2425
D2440
D2450
D2475
-
-
-
HD4850
HD6075
-
RSSD-10A
RSSD-25A
RSSD-40A
-
-
-
-
-
-
-
-
EOM1DA44-4-32
SSR240D25
-
SSR240D50
-
-
SSR480D25
-
SSR480D50
-
NOMINAL
VOLTAGE RANGE MAX. CURRENT
RATING
W6202DSX-1
W6210DSX-1
*W6225DSX-1
W6240DSX-1
W6250DSX-1
W6275DSX-1
90 -280 VAC
90 -280 VAC
90 -280 VAC
90 -280 VAC
90 -280 VAC
90 -280 VAC
90 -280 VAC
90 -280 VAC
90 -280 VAC
90 -280 VAC
90 -280 VAC
280 VAC
280 VAC
280 VAC
280 VAC
280 VAC
280 VAC
560 VAC
560 VAC
560 VAC
560 VAC
560 VAC
2.5 AMPS
10 AMPS
25 AMPS
40 AMPS
50 AMPS
75 AMPS
10 AMPS
25 AMPS
40 AMPS
50 AMPS
75 AMPS
-
-
SSR240A25
-
SSR240A50
-
-
SSR480A25
-
SSR480A50
-
W6202ASX-1
W6210ASX-1
*W6225ASX-1
W6240ASX-1
W6250ASX-1
W6275ASX-1
24-240 VAC
24-240 VAC
24-240 VAC
24-240 VAC
24-240 VAC
24-240 VAC
48-480 VAC
48-480 VAC
48-480 VAC
48-480 VAC
48-480 VAC
A2402
A2410
A2425
A2440
A2450
A2475
-
HA4825
-
HA4850
HA4875
-
RSSA-10A
RSSA-25A
RSSA-40A
-
-
-
-
-
-
-
W6210DTX-3 3.5-32 VDC 280 VAC24-240 VAC 10 AMPS
MAX.
VOLTAGE
CONTROL
VOLTAGE RANGE 3 VDC
3 VDC
3 VDC
3 VDC
3 VDC
3 VDC
3 VDC
3 VDC
3 VDC
3 VDC
3 VDC
90 VAC
90 VAC
90 VAC
90 VAC
90 VAC
90 VAC
90 VAC
90 VAC
90 VAC
90 VAC
90 VAC
10 VAC
10 VAC
10 VAC
10 VAC
10 VAC
10 VAC
10 VAC
10 VAC
10 VAC
10 VAC
10 VAC
3VDC 1 VDC
MAX
PULL-IN MIN
DROP OUT
MAX
PULL-IN MIN
DROP OUT
W6410DSX-1
W6425DSX-1
W6440DSX-1
W6450DSX-1
W6475DSX-1
1 VDC
1 VDC
1 VDC
1 VDC
1 VDC
1 VDC
1 VDC
1 VDC
1 VDC
1 VDC
1 VDC
W6410ASX-1
W6425ASX-1
W6440ASX-1
W6450ASX-1
W6475ASX-1
W6212DDX-1
W6225DDX-1
W6240DDX-1
3.5 - 32 VDC
3.5 - 32 VDC
3.5 - 32 VDC
0 -200 VDC
0 -200 VDC
0 -200 VDC
12 AMPS
25 AMPS
40 AMPS
D2D12
D1D20*
D1D40*
W6210DTX-1
W6225DTX-1
W6410DTX-1
3-32 VDC
3-32 VDC
3-32 VDC
280 VAC
280 VAC
500 VAC
10 AMPS
25 AMPS
10 AMPS
SSRT240D10
-
-
24-240 VAC
24-240 VAC
48-480 VAC
TD2410
-
-
CRYDOM
3 VDC
3 VDC
3 VDC
1 VDC
1 VDC
1 VDC
3.5VDC
3.5VDC
3.5VDC
1 VDC
1 VDC
1 VDC
MAX
PULL-IN MIN
DROP OUT
DC CONTROLLED
DC OUTPUT
DC CONTROLLED
AC OUTPUT
OUTPUT(Over Operating Temperature Range)
INPUT(Over Operating Temperature Range)
OUTPUT
(Over Operating Temperature Range)
CROSS REFERENCE
CROSS REFERENCE
Av ailable from Your Local Magnecraft & Struthers- Dunn Distributors.
PART NUMBERS
MAX.
VOLTAGE CRYDOM POTTER &
BRUMFIELD
MAX
PULL-IN MIN
DROP OUT
OUTPUT(Over Operating Temperature Range)INPUT (Over Operating Temperature Range)
CROSS REFERENCEPART NUMBERS
OUTPUT(Over Operating Temperature Range)
INPUT (Over Operating Temperature Range)
CROSS REFERENCE
PART NUMBERS
DC CONTROLLED
AC OUTPUT DPST NO
DC CONTROLLED
AC TRIAC OUTPUT
OUTPUT(Over Operating Temperature Range)
INPUT(Over Operating Temperature Range)
PART NUMBERS
*Certified
*Certified
*Crydom relays only rated at 0-100 VDC
W6690DSX-1
W66125DSX-1 3-32 VDC
3-32 VDC 660 VAC
660 VAC 90 AMPS
125 AMPS
-
-
48-600 VAC
48-600 VAC HD6090
HD60125
3 VDC
3 VDC 1 VDC
1 VDC
MAX.
VOLTAGE CRYDOM POTTER &
BRUMFIELD
NOMINAL
VOLTAGE RANGE MAX.
CURRENT RATING
CONTROL
VOLTAGE RANGE MAX
PULL-IN MIN
DROP OUT
OUTPUT(Over Operating Temperature Range)INPUT (Over Operating Temperature Range)
CROSS REFERENCEPART NUMBERS
DC CONTROLLED
AC OUTPUT
W6690ASX-1
W66125ASX-1 90-280 VAC
90-280 VAC 660 VAC
660 VAC 90 AMPS
125 AMPS
-
-
48-600 VAC
48-600 VAC HA6090
HA60125
90 VDC
90 VDC 10 VDC
10 VDC
OUTPUT(Over Operating Temperature Range)INPUT (Over Operating Temperature Range)
CROSS REFERENCEPART NUMBERS
AC CONTROLLED
AC OUTPUT
OUTPUT(Over Operating Temperature Range)INPUT(Over Operating Temperature Range)
CROSS REFERENCEPART NUMBERS
MAX.
VOLTAGE IDEC
CRYDOM POTTER &
BRUMFIELD
NOMINAL
VOLTAGE RANGE MAX. CURRENT
RATING
CONTROL
VOLTAGE RANGE MAX
PULL-IN MIN
DROP OUT
AC CONTROLLED
AC OUTPUT
MAX.
VOLTAGE CRYDOM POTTER &
BRUMFIELD
NOMINAL
VOLTAGE RANGE MAX.
CURRENT RATING
CONTROL
VOLTAGE RANGE MAX
PULL-IN MIN
DROP OUT
NOMINAL
VOLTAGE RANGE MAX.
CURRENT RATING
CONTROL
VOLTAGE RANGE
NOMINAL
VOLTAGE RANGE MAX.
CURRENT RATING
CONTROL
VOLTAGE RANGE
NOMINAL
VOLTAGE RANGE MAX.
CURRENT RATING
CONTROL
VOLTAGE RANGE