Your Contact for Relays SOLID STATE RELAYS CLASS 70S2 MINIATURE SSR's (FORMERLY GRAYHILL) 2.5 Amp to 25 Amp Outputs CLASS 6 SSR's 2.5 Amp to 125 Amp Outputs ! W E . N SR's S HILL T. Y A VOL GR 0 6 6 S6 S . A CL -N.O T S SP PUT T U LO DUA .O. N T DPS EAR L C SS 6 ER. V CLA O C ETY F A S * * * * PRODUCT MARKETING BULLETIN 2000 SSR SOLID STATE RELAYS PART NUMBER EXPLANATION 70S2- 04- D- 03- V Optically Isolated Solid State Relay Control Voltage 01 = 2 - 15 VDC, DC/DC Relays 02 = 9 - 30 VDC, DC/DC Relays 03 = 3 - 30 VDC, 25 A mini - puck 04 = 3 - 30 VDC, DC/AC Relays 05 = 6 - 30 VDC, DC/AC Relays Nominal Voltage A = 3-60 VDC B = 120 VAC C = 240 VAC D = 24 VAC Max Current Rating 02 = 2.5 A 04 = 4 A 06 = 6 A 12 = 12 A 03 = 3 A 05 = 5 A 10 = 10A 25 = 25 A Package Style F, H, L, M, N, S or V. See selection below. BENEFITS CLASS 70S2 SSR's * EXCELLENT TRANSIENT PROTECTION * HIGH SURGE CURRENT CAPABILITY * OPTICALLY ISOLATED * HIGH BLOCKING VOLTAGE * EXTREMELY LONG LIFE * MINIATURE BUT MIGHTY; UP TO 25 AMP SWITCHING DC INPUT-AC OUTPUT MAX. LOAD CURRENT CONTROL VOLTAGE NOMINAL LOAD VOLTAGE DESCRIPTION AND FEATURES 2.5 A 3A 4A 3-30 or 6-30 VDC 24, 120 or 240 VAC MICRO CUBE RELAY, ONLY 0.500" HIGH 3-32 or 6-32 VDC 24, 120 or 240 VAC SINGLE IN - LINE PACKAGE, USES ONLY 0.680 SQ. INCHES BOARD AREA 3-30 or 6-30 VDC 3-30 or 6-30 VDC 24, 120 or 240 VAC 120 or 240 VAC MINI CUBE RELAY, PC MOUNT 6A 6A 6A 6A 3-30 or 6-30 VDC 3-30 or 6-30 VDC 120 or 240 VAC 120 or 240 VAC USE HEAT SINK OR PANEL MOUNT USE HEAT SINK OR PANEL MOUNT MINI PUCK RELAY, PANEL MOUNT, FIT/FUNCTION REPLACEMENTS FOR LARGER HOCKEY PUCK STYLES, TAP TERMINALS 3-30 or 6-30 VDC 120 or 240 VAC MINI PUCK RELAY, PANEL MOUNT, FIT/FUNCTION 3-30 or 6-30 VDC 120 or 240 VAC USE HEAT SINK OR PANEL MOUNT 3-30 or 6-30 VDC 120 or 240 VAC MINI PUCK RELAY, PANEL MOUNT, FIT/FUNCTION 12 A 3-30 or 6-30 VDC 120 or 240 VAC REPLACEMENTS FOR LARGER HOCKEY PUCK STYLES, TAP TERMINALS MINI PUCK RELAY, PANEL MOUNT, FIT/FUNCTION REPLACEMENTS FOR LARGER HOCKEY PUCK STYLES, SCREW TERMINALS 25 A H V F L M N S REPLACEMENTS FOR LARGER HOCKEY PUCK STYLES, SCREW TERMINALS 12 A 10 A STYLE MINI PUCK RELAY, PANEL MOUNT, FIT/FUNCTION 3-30 VDC M N S S REPLACEMENTS FOR LARGER HOCKEY PUCK STYLES, SCREW TERMINALS DC INPUT-DC OUTPUT MAX. LOAD CURRENT CONTROL VOLTAGE NOMINAL LOAD VOLTAGE DESCRIPTION AND FEATURES STYLE 3A 3-15 or 9-30 VDC 3 to 60 VDC SINGLE IN - LINE PACKAGE, USES ONLY 0.680 SQ . INCHES BOARD AREA V 3A 3 to 60 VDC MINI CUBE RELAY, PC MOUNT F 5A 3-15 or 9-30 VDC 3-15 VDC 3 to 60 VDC MINI PUCK RELAY, PANEL MOUNT, FIT/FUNCTION REPLACEMENTS FOR LARGER HOCKEY PUCK STYLES, TAP TERMINALS N 5A 3-15 VDC 3 to 60 VDC MINI PUCK RELAY, PANEL MOUNT, FIT/FUNCTION REPLACEMENTS FOR LARGER HOCKEY PUCK STYLES, SCREW TERMINALS S STYLE "V" "V" STYLE Figure 2: Maximum Peak Surge Current vs. FIGURE 1: Maximum Continuous Current VS . LOAD CURRENT (AMPS ) Ambient Temperature Surge Duration 300 200 100 80 60 3 2 40 30 1 20 10 -40 -20 0 20 40 60 -80 100 AMBIENT TEMPERATURE (C) OUTLINE DIMENSIONS 6 4 3 1 Dimensions Shown in Inch and (Millimeter). 1 1 2 3 4 6 10 20 40 60 100 1000 SURGE CURRENT DURATION-FULL CYCLES 1.700 (43.18) FIGURE 1 CHART INDICATES CONTINUOUS CURRENT TO LIMIT THE JUNCTION TEMPERATURES TO 100 C. INFORMATION IS BASED ON STEADY STATE HEAT TRANSFER IN A 2 CUBIC FOOT SEALED ENCLOSURE. 1.000 (25.4) 0.235 0.020 5.97 0.51 0.300 (7.62) 0.400 (10.16) 0.900 (22.86) 1.100 (27.94) OBSERVE POLARITY ON DC OUTPUT STYLES FIGURE 2 CHART INFORMATION IS BASED ON A SUPPLY FREQUENCY OF 60 HERTZ SINUSOIDAL AND A RESISTIVE OR INDUCTIVE LOAD. APPLICATION OF MAXIMUM SURGE CURRENT MAY NOT BE REPEATED UNTIL THE RELAY TEMPERATURE HAS RETURNED TO ITS STEADY STATE VALUE. 0.400 (10.16) 0.040 / 0.042 DIA. (O 1.04) TYP. FEATURES * SINGLE IN LINE PACKAGE RELAY * OPTICALLY ISOLATED * PC MOUNT FOR LOADS UP TO 3 AMPS * MINIMAL BOARD SPACE REQUIRED * TUV RHEINLAND CERTIFIED TO EN60947 - 5 - 1 SAFETY REQUIREMENTS ( 24VAC, 120 VAC, 240 VAC STYLES.) * LIFETIME WARRANTY 0.1000 (2.54) GENERAL SPECIFICATIONS INPUT CHARACTERISTICS Input voltage range: Max.Reverse Control voltage: Input current: Average Input Impedance: OUTPUT CHARACTERISTICS Max. Load Current : Load Voltage Range (VAC): Minimum Load Current IT MIN (RMS) to maintain "ON": Maximum Off State Leakage current ID (RMS): Maximum On-State Voltage VT drop: Maximum off-state dv/dt: Operating Frequency Range: One Cycle surge current: Minimum Peak Blocking voltage: Turn - On Time (60Hz): Turn - Off Time (60Hz): MISCELLANEOUS CHARACTERISTICS Output configuration: Dielectric Strength VISO (Input-Output Isolation): Insulation Resistance : Operating temperature Range: Storage temperature Range: Weight: 3-32 VDC 5 VDC 1.0 -19.0 mA 2000 6-32 VDC 5 VDC 1.0 -6.0 mA 6000 3 Amps 24 V=10-50 V, 120 V=24-140 V, 240 V=24-280 V 65 mA 24 V=4 mA, 120 V=6 mA, 240 V=6 mA 1.5 V Peak Max. 3000 V/ microsecond. 25 Hz to 70 Hz 60 Amps Peak Max.(@ 25C) 24 V= 200 V, 120 V= 400 V, 240 V= 600 V 8.3 mS Maximum. 8.3 mS Maximum. Normally Open 3000 V rms. Min. 109 -40C to +100C -40C to +125C 19 g. " N " & " S " STYLE STYLE S STYLE N OUTLINE DIMENSIONS Dimensions shown in Inch and (Millimeter). 0.230 MIN (5.842) 0.270 MIN (6.858) (4)6-32 SCREWS AND WASHERS PROVIDED 0.864 (21.95)MAX. 0.864 (21.95)MAX. 0.980 (24.89) MAXIMUM SCREW TORQUE = 9 IN - LBS NOTE: STYLE S IS NOT INTENDED FOR PC BOARD MOUNTING. 2.200 (55.88) CONSULT FACTORY 1.870 (47.50) 1.200 (30.48) 0.176 (4.47) (1) (4) 0.500 1.000 (12.7) (25.4) 0.400 (10.16) (2) 2 TERMINALS 0.187 (4.75) (3) 0.900 (22.86) DC INPUT (1) + (2) (4) AC SUPPLY (3) + LOAD OBSERVE POLARITY ON DC OUTPUT STYLES 2 TERMINALS 0.250 (6.35) 2.200 (55.88) 1.870 (47.50) 1.200 (30.48) FEATURES * MINI PUCK SOLID RELAYS * OPTICALLY ISOLATED * PANEL MOUNT; UP TO 25 AMP LOADS * MOUNTS ON HOCKEY PUCK RELAY CENTERS, YET NEEDS 1/2 THE SPACE * SCREW TERMINALS OR PUSH - ON QC TERMINALS * LIFETIME WARRANTY 0.176 (4.47) (1) (4) 0.600 1.000 (15.24) (25.4) 0.400 (10.16) (2) (3) 0.750 (19.05) "V" &"S" STYLE Figure 2: Maximum Peak Surge Current vs. FIGURE 1: Maximum Continuous Current VS . Surge Duration Ambient Temperature 300 25 AMP LOAD CURRENT (AMPS ) 200 STYLE S, 25A 25 20 15 STYLE N & S, 12A 10 STYLE N & S, 6A 5 100 80 60 12 AMP 40 30 6 AMP 20 10 6 -40 -20 0 20 40 60 -80 100 AMBIENT TEMPERATURE (C) 4 3 1 1 1 FIGURE 1 CHART INDICATES CONTINUOUS CURRENT TO LIMIT THE JUNCTION TEMPERATURES TO 100 C. INFORMATION IS BASED ON STEADY STATE HEAT TRANSFER IN A 2 CUBIC FOOT SEALED ENCLOSURE. FIGURE 2 CHART INFORMATION IS BASED ON A SUPPLY FREQUENCY OF 60 HERTZ SINUSOIDAL AND A RESISTIVE OR INDUCTIVE LOAD. APPLICATION OF MAXIMUM SURGE CURRENT MAY NOT BE REPEATED UNTIL THE RELAY TEMPERATURE HAS RETURNED TO ITS STEADY STATE VALUE. GENERAL SPECIFICATIONS INPUT CHARACTERISTICS Input Voltage Range: Max. Reverse Control Voltage: Input Current: Average Input Impedance @ 24 VDC Typ.: OUTPUT CHARACTERISTICS Max. Load Current : Load Voltage Range (VAC): Minimum Load Current IT MIN (RMS) to Maintain "ON": Maximum Off State Leakage Current ID (RMS): Maximum On-State Voltage V T Drop: Maximum Off-State dv/dt: Operating Frequency Range: One Cycle Surge Current: Minimum Peak Blocking Voltage: Turn - On Time (60Hz): MTurn - Off Time (60Hz):S MISCELLANEOUS CHARACTERISTICS Output Configuration: Dielectric Strength VISO (Input-Output Isolation): Insulation Resistance: Operating Temperature Range: Storage Temperature Range: Weight: 3-30 VDC 2 3 4 6 10 20 40 60 100 1000 SURGE CURRENT DURATION-FULL CYCLES 6-30 VDC 5 VDC 5 VDC 7.0 -16.0 mA 6.0 -10.0 mA 1777 2750 6 , 12 & 25 Amps 120 = 24-140 VAC, 240= 24-280 VAC 6 Amps = 75 mA, 12 & 25 Amps = 100 mA 120 V =6 mA, 240 V =6 mA 1.6 V Peak Max. 3000 V/ microsecond typical. 25 Hz to 70 Hz 60, 150 & 300 Amps Peak Max. 120 = 400 V, 240 = 600 V 8.3 mS Maximum. 8.3 mS Maximum. Normally Open. 3000 V rms. Min. 109 -40C to +100C -40C to +125C 35 g. Style N, 56 g. Style S Appox. " F " & " M" STYLE OUTLINE DIMENSIONS Dimensions shown in Inch and (Millimeter). 2.200 (55.88) 1.200 (30.48) 0.830 (21.08)MAX. 0.850 (21.59)MAX. 0.250 MIN. (6.35) 0.250 MIN. (6.35) DC INPUT (1) + (2) (4) AC SUPPLY (3) + LOAD OBSERVE POLARITY ON DC OUTPUT STYLES 2.200 (55.88) STYLE F STYLE M 1.870 (47.50) 1.200 (30.48) 0.176 (4.47) (4) (1) 0.600 1.000 (15.24) (25.4) 0.400 (10.16) (2) (3) 0.300 (7.62) 0.300 (7.62) 4 SQ. PINS 0.025 (0.64) FEATURES * CUBE RELAYS WITH EXTENDED CURRENT RATINGS * PC MOUNT OPTICALLY ISOLATED * INTEGRAL HEAT SINK ACCOMMODATES PANEL MOUNT OR ADD-ON HEAT SINK * SWITCHES UP TO 4 , 6 OR 10 AMP LOADS * LIFETIME WARRANTY "F" &"M" STYLE Figure 2: Maximum Peak Surge Current vs. FIGURE 1: Maximum Continuous Current VS . Surge Duration Ambient Temperature 300 LOAD CURRENT (AMPS ) 200 14 12 STYLE M, 10A 10 8 6 STYLE M, 6A STYLE F, 4A 4 2 100 80 60 10 AMP 40 30 4 & 6 AMP 20 10 6 -40 -20 0 20 40 60 -80 100 AMBIENT TEMPERATURE (C) 4 3 1 1 1 2 3 4 6 10 20 40 60 100 1000 SURGE CURRENT DURATION-FULL CYCLES FIGURE 1 CHART INDICATES CONTINUOUS CURRENT TO LIMIT THE JUNCTION TEMPERATURES TO 100 C. INFORMATION IS BASED ON THE USE OF A 12" X 12" X 1/8" ALUMINUM HEAT SINK WITH SILICON GREASE IN A 2 CUBIC FOOT SEALED ENCLOSURE. FIGURE 2 CHART INFORMATION IS BASED ON A SUPPLY FREQUENCY OF 60 HERTZ SINUSOIDAL AND A RESISTIVE OR INDUCTIVE LOAD. APPLICATION OF MAXIMUM SURGE CURRENT MAY NOT BE REPEATED UNTIL THE RELAY TEMPERATURE HAS RETURNED TO ITS STEADY STATE VALUE. GENERAL SPECIFICATIONS INPUT CHARACTERISTICS Input Voltage Range: Max Reverse Control Voltage: Input Current: Average Input Impedance @ 24 VDC Typ.: OUTPUT CHARACTERISTICS Max. Load Current : Load Voltage Range (VAC) Minimum Load Current IT MIN (RMS) to Maintain "ON": Maximum Off State Leakage Current ID (RMS): Maximum On-State Voltage V T Drop: Maximum Off-State dv/dt: Operating Frequency Range: One Cycle Surge Current: Minimum Peak Blocking Voltage: Turn - On Time (60Hz): MTurn - Off Time (60Hz):S MISCELLANEOUS CHARACTERISTICS Output Configuration: Dielectric Strength VISO (Input-Output Isolation): Insulation Resistance : Operating Temperature Range: Storage Temperature Range: Weight: 3-30 VDC 6-30 VDC 5 VDC 5 VDC 7.0 -16.0 mA 6.0 -10.0 mA 1777 2750 4, 6 & 10 Amps 24-140 VAC, 24-280 VAC 75 mA 6 mA 1.5 V Peak Max. 3000 V/ microsecond typical. 25 Hz to 70 Hz 4 = 60, 6 = 60, 10 =110 Amps Peak Max. 120=400 V, 240=600 V 8.3 mS Maximum. 8.3 mS Maximum. Normally Open. 3000 V rms. Min. 109 -40C to +100C -40C to +125C 30 g. Style F, 52 g. Style M Appox. " H " & " L " STYLE OUTLINE DIMENSIONS Dimensions shown in Inch and (Millimeter). 2.200 (55.88) 1.200 (30.48) 0.520 (13.21) MAX. 0.516 (13.1) MAX. 0.185 MIN. (4.74) 0.185 MIN. (4.70) DC INPUT (1) + (2) (4) AC SUPPLY (3) + LOAD OBSERVE POLARITY ON DC OUTPUT STYLES STYLE L STYLE H 0.200 (5.08) (4) (1) 0.600 (15.24) 0.400 (10.16) (2) (3) 0.300 (7.62) 4 SQ. PINS 0.025 (0.64) FEATURES * MICRO CUBE SOLID STATE RELAY * OPTICALLY ISOLATED * PC MOUNT ONLY 0.5" ABOVE BOARD * MINIMAL BOARD SPACE REQUIRED * LIFETIME WARRANTY 0.450 MIN. (11.43) 0.300 MIN. (7.62) 1.000 (25.4) "H" &"L" STYLE Figure 2: Maximum Peak Surge Current vs. FIGURE 1: Maximum Continuous Current VS . Surge Duration LOAD CURRENT (AMPS ) Ambient Temperature 8 7 6 5 4 3 2 1 300 200 STYLE L, 6A 100 80 60 40 30 STYLE H, 2.5A 2.5 & 6 AMP 20 10 6 -40 -20 0 20 40 60 -80 100 AMBIENT TEMPERATURE (C) 4 3 1 1 1 2 3 4 6 10 20 40 60 100 1000 SURGE CURRENT DURATION-FULL CYCLES FIGURE 1 CHART INDICATES CONTINUOUS CURRENT TO LIMIT THE JUNCTION TEMPERATURES TO 100 C. INFORMATION IS BASED ON THE USE OF A 12" X 12" X 1/8" ALUMINUM HEAT SINK WITH SILICON GREASE IN A 2 CUBIC FOOT SEALED ENCLOSURE. FIGURE 2 CHART INFORMATION IS BASED ON A SUPPLY FREQUENCY OF 60 HERTZ SINUSOIDAL AND A RESISTIVE OR INDUCTIVE LOAD. APPLICATION OF MAXIMUM SURGE CURRENT MAY NOT BE REPEATED UNTIL THE RELAY TEMPERATURE HAS RETURNED TO ITS STEADY STATE VALUE. GENERAL SPECIFICATIONS INPUT CHARACTERISTICS Input Voltage Range: Max Reverse Control Voltage: Input current: Average Input Impedance @ 24 VDC Typ.: OUTPUT CHARACTERISTICS Max. Load Current : Load Voltage Range (VAC): Minimum Load Current IT MIN (RMS) to maintain "ON": Maximum Off State Leakage current ID (RMS): Maximum On-State Voltage VT drop: Maximum off-state dv/dt: Operating Frequency Range: One Cycle surge current: Minimum Peak Blocking voltage: Turn - On Time (60Hz): Turn - Off Time (60Hz): MISCELLANEOUS CHARACTERISTICS Output configuration: Dielectric Strength VISO (Input-Output Isolation): Insulation Resistance : Operating Temperature Range: Storage Temperature Range: Weight: 3-32 VDC 5 VDC 1.0 -18.0 mA 2777 6-30 VDC 5 VDC 1.0 -6.0 mA 6000 2.5 & 6.0 Amps 24 V=10-50 V, 120 V=24-140 V, 240 V=24-280 V 75 mA 24V= 4 mA120 V=6 mA, 240 V=6 mA 1.5 V Peak Max. 3000 V/microsecond typical. 25 Hz to 70 Hz 60 Peak Max. 24 V= 200 V, 120 V= 400 V, 240 V= 600 V 8.3 mS Maximum. 8.3 mS Maximum. Normally Open. 2500 V rms. Min. 109 -40C to +100C -40C to +125C 20 g. Style H, 22 g. Style L Appox. Available from Your Local Magnecraft & Struthers- Dunn Distributors. PART NUMBERS DC CONTROLLED AC OUTPUT INPUT (Over Operating Temperature Range) CONTROL VOLTAGE RANGE MAX. PULL - IN MIN DROP OUT FORMERLY GRAYHILL OUTPUT (Over Operating Temperature Range) NOMINAL VOLTAGE RANGE MAX. VOLTAGE MAX. CURRENT RATING STYLE TYPE 70S2-04-D-03-V 70S2-05-D-03-V 70S2-04-B-03-V 70S2-05-B-03-V 70S2-04-C-03-V 70S2-05-C-03-V 3-32 VDC 6-32 VDC 3-32 VDC 6-32 VDC 3-32 VDC 6-32 VDC 3 VDC 6 VDC 3 VDC 6 VDC 3 VDC 6 VDC 1 VDC 1 VDC 1 VDC 1 VDC 1 VDC 1 VDC 10 - 50 AC 10 - 50 AC 24 - 140 AC 24 - 140 AC 24 - 280 AC 24 - 280 AC 50 VAC 50 VAC 140 VAC 140 VAC 280 VAC 280 VAC 3 AMPS 3 AMPS 3 AMPS 3 AMPS 3 AMPS 3 AMPS V V V V V V 70S2-04-D-02-H 70S2-05-D-02-H 70S2-04-B-02-H 70S2-05-B-02-H 70S2-04-C-02-H 70S2-05-C-02-H 3-30 VDC 6-30 VDC 3-30 VDC 6-30 VDC 3-30 VDC 6-30 VDC 3 VDC 6 VDC 3 VDC 6 VDC 3 VDC 6 VDC 1 VDC 1 VDC 1 VDC 1 VDC 1 VDC 1 VDC 10 - 50 AC 10 - 50 AC 24 - 140 AC 24 - 140 AC 24 - 280 AC 24 - 280 AC 50 VAC 50 VAC 140 VAC 140 VAC 280 VAC 280 VAC 2.5 AMPS 2.5 AMPS 2.5 AMPS 2.5 AMPS 2.5 AMPS 2.5 AMPS H H H H H H 70S2-04-B-06-L 70S2-05-B-06-L 70S2-04-C-06-L 70S2-05-C-06-L 3-30 VDC 6-30 VDC 3-30 VDC 6-30 VDC 3 VDC 6 VDC 3 VDC 6 VDC 1 VDC 1 VDC 1 VDC 1 VDC 24 - 140 AC 24 - 140 AC 24 - 280 AC 24 - 280 AC 140 VAC 140 VAC 280 VAC 280 VAC 6 AMPS 6 AMPS 6 AMPS 6 AMPS L L L L 70S2-04-B-04-F 70S2-05-B-04-F 70S2-04-C-04-F 70S2-05-C-04-F 3-30 VDC 6-30 VDC 3-30 VDC 6-30 VDC 3 VDC 6 VDC 3 VDC 6 VDC 1 VDC 1 VDC 1 VDC 1 VDC 24 - 140 AC 24 - 140 AC 24 - 280 AC 24 - 280 AC 140 VAC 140 VAC 280 VAC 280 VAC 4 AMPS 4 AMPS 4 AMPS 4 AMPS F F F F 70S2-04-B-06-M 70S2-05-B-06-M 70S2-04-B-10-M 70S2-05-B-10-M 70S2-04-C-06-M 70S2-05-C-06-M 70S2-04-C-10-M 70S2-05-C-10-M 3-30 VDC 6-30 VDC 3-30 VDC 6-30 VDC 3-30 VDC 6-30 VDC 3-30 VDC 6-30 VDC 3 VDC 6 VDC 3 VDC 6 VDC 3 VDC 6 VDC 3 VDC 6 VDC 1 VDC 1 VDC 1 VDC 1 VDC 1 VDC 1 VDC 1 VDC 1 VDC 24 - 140 AC 24 - 140 AC 24 - 140 AC 24 - 140 AC 24 - 280 AC 24 - 280 AC 24 - 280 AC 24 - 280 AC 140 VAC 140 VAC 140 VAC 140 VAC 280 VAC 280 VAC 280 VAC 280 VAC 6 AMPS 6 AMPS 10 AMPS 10 AMPS 6 AMPS 6 AMPS 10 AMPS 10 AMPS M M M M M M M M 70S2-04-B-06-N 70S2-05-B-06-N 70S2-04-B-12-N 70S2-05-B-12-N 70S2-04-C-06-N 70S2-05-C-06-N 70S2-04-C-12-N 70S2-05-C-12-N 3-30 VDC 6-30 VDC 3-30 VDC 6-30 VDC 3-30 VDC 6-30 VDC 3-30 VDC 6-30 VDC 3 VDC 6 VDC 3 VDC 6 VDC 3 VDC 6 VDC 3 VDC 6 VDC 1 VDC 1 VDC 1 VDC 1 VDC 1 VDC 1 VDC 1 VDC 1 VDC 24 - 140 AC 24 - 140 AC 24 - 140 AC 24 - 140 AC 24 - 280 AC 24 - 280 AC 24 - 280 AC 24 - 280 AC 140 VAC 140 VAC 140 VAC 140 VAC 280 VAC 280 VAC 280 VAC 280 VAC 6 AMPS 6 AMPS 12 AMPS 12 AMPS 6 AMPS 6 AMPS 12 AMPS 12 AMPS N N N N N N N N 70S2-04-B-06-S 70S2-05-B-06-S 70S2-04-B-12-S 70S2-05-B-12-S 70S2-03-B-25-S 70S2-04-C-06-S 70S2-05-C-06-S 70S2-04-C-12-S 70S2-05-C-12-S 70S2-03-C-25-S 3-30 VDC 6-30 VDC 3-30 VDC 6-30 VDC 3-30 VDC 3-30 VDC 6-30 VDC 3-30 VDC 6-30 VDC 3-30 VDC 3 VDC 6 VDC 3 VDC 6 VDC 3 VDC 3 VDC 6 VDC 3 VDC 6 VDC 3 VDC 1 VDC 1 VDC 1 VDC 1 VDC 1 VDC 1 VDC 1 VDC 1 VDC 1 VDC 1 VDC 24 - 140 AC 24 - 140 AC 24 - 140 AC 24 - 140 AC 24 - 140 AC 24 - 280 AC 24 - 280 AC 24 - 280 AC 24 - 280 AC 24 - 280 AC 140 VAC 140 VAC 140 VAC 140 VAC 140 VAC 280 VAC 280 VAC 280 VAC 280 VAC 280 VAC 6 AMPS 6 AMPS 12 AMPS 12 AMPS 25 AMPS 6 AMPS 6 AMPS 12 AMPS 12 AMPS 25 AMPS S S S S S S S S S S NOMINAL VOLTAGE RANGE MAX. VOLTAGE MAX. CURRENT RATING STYLE TYPE CONTROL VOLTAGE RANGE 70S2-01-A-03-V 70S2-02-A-03-V 70S2-01-A-03-F 70S2-02-A-03-F 70S2-01-A-05-N 70S2-01-A-05-S 70S2-02-A-05-S 3-15 VDC 9-30 VDC 3-15 VDC 9-30 VDC 3-15 VDC 3-15VDC 9-30 VDC MAX. PULL - IN 3 VDC 9 VDC 3 VDC 9 VDC 3 VDC 3 VDC 9 VDC MIN DROP OUT 1 VDC 1 VDC 1 VDC 1 VDC 1 VDC 1 VDC 1 VDC 3 - 60 VDC 3 - 60 VDC 3 - 60 VDC 3 - 60 VDC 3 - 60 VDC 3 - 60 VDC 3 - 60 VDC 60 VDC 60 VDC 60 VDC 60 VDC 60 VDC 60 VDC 60 VDC 3 AMPS 3 AMPS 3 AMPS 3 AMPS 5 AMPS 5 AMPS 5 AMPS V V F F N S S SOLID STATE RELAY C US On selected Models. BENEFITSCLASS 6 SSR's * * * * 3 2 1 Free Air Mounting 0 20 40 60 80 100 10 Amp Styles 16 14 6" x 6" x 1/8" Aluminum Plate Heat Sink with 1C/W thermal resistance. 10 8 6 4 Free Air Mounting 2 0 20 40 60 25 Amp Styles 40 12 MAX. AMBIENT TEMPERATURE (C) UP TO 660 VOLT OUTPUTS LOAD CURRENT (AMPS RMS) 6" x 6" x 1/8" Aluminum Plate LOAD CURRENT (AMPS RMS) LOAD CURRENT (AMPS RMS) 2.5 Amp Style L.E.D. STATUS LAMP CLEAR SAFETY COVER SINGLE AND DUAL OUTPUTS 80 100 Mounted on Heat Sink with 1C/W thermal resistance. (Sink to Ambient) 35 30 25 20 15 6" x 6" x 1/8" 10 Aluminum Plate 1.5C/W 5 Free Air Mounting 0 20 MAX. AMBIENT TEMPERATURE (C) 40 60 80 100 MAX. AMBIENT TEMPERATURE (C) THERMAL DERATING CURVE & LOAD CHARACTERISTICS 1C/W thermal resistance. 70 0.14C/W (50A) 50 6" x 6" x 1/8" Aluminum Plate 40 30 20 10 ree Air Mounting 0 F 20 40 60 80 100 MAX. AMBIENT TEMPERATURE (C) -90 60 6" x 6" x 1/8" Aluminum Plate 45 0.14C/W 40 -95 -100 30 -105 20 -110 10 0 90 & 125 Amp Styles 180 LOAD CURRENT (AMPS RMS) 80 Mounted on Heat Sink with LOAD CURRENT (AMPS RMS) LOAD CURRENT (AMPS RMS) 90 MAX. ALLOWABLE TEMPERATURE 75 Amp Styles 75 40 & 50 Amp Styles 160 140 Heat sink 0.14C/W 125 Amp 120 Fan output 70 CFM With Fan 100 90 Amp 80 60 40 Without Fan 20 10 20 30 40 50 60 70 80 10 20 30 40 50 60 70 80 90 MAX. AMBIENT TEMPERATURE (C) MAX. AMBIENT TEMPERATURE (C) 0 All current ratings in the following pages are based on use of suitable thermally conductive compound (e.g. silicone grease between the SSR mounting base and mounting surface of suitable heat sink). OUTLINE DIMENSIONS Dimensions Shown in Inch and (Millimeter). SPST-N.O. INPUT & OUTPUT SCREW SIZE (Shown in Millimeters) 2.250 (57.2) UP TO 40 AMP INPUT 3.5 mm ABOVE 40 AMP 3.5 mm RED LED LAMP . .O -N 1.750 (44.5) T PS RED L.E.D. OUTPUT 4 mm 6 mm LIFETIME WARRANTY S OUTPUT INPUT S AFE TY COV E R 2.665 (67.691) 0.475 (12.065) 0.800 (20.32) DPST-N.O. 2.250 (57.2) 0.996 max. (25.3) for 75 & 50-40 Amp DDX models & for 75 to 125 Amps DSX & ASX models. 0.800 max (20.32) for models ASX, DSX & DTX models up to 50 Amps & DDX 12 Amps models. 1.945 (49.403) 1.750 (44.5) RED L.E.D. RED LED LAMP 0.250" (6.35) QC 0.187" (4.74) QC DP -N ST INPUT .O. 0.800 max (20.32) GENERAL SPECIFICATIONS INPUT CHARACTERISTICS Input Voltage Range: Power Indicator: Reverse Polarity Protected: Input Filtered for Transients less than One Millisecond: Input Current: Input Impedence: OUTPUT CHARACTERISTICS Max. Load Current : Load Voltage Range (VAC) Maximum Output Voltage (VAC): Minimum Load Current IT MIN (RMS) to Maintain "ON" Maximum Off State Leakage Current I D (RMS): Maximum On-State Voltage Drop VT (RMS): Maximum Off-State dv/dt: Turn - On Time (60Hz): Turn - Off Time (60Hz): MISCELLANEOUS CHARACTERISTICS Output Configuration: Dielectric Strength VISO (Input-Output Isolation): Insulation Resistance RISO @ 500VDC: Operating Temperature Range: Storage Temperature Range: Life: Weight: CONSULT FACTORY FOR SPECIALS 3-32 VDC, 90 - 280 VAC and 3.5 to 32 VDC (DDX) L.E.D. Indicator. Yes: DC Input with AC output styles only. Yes 8mA@ 3VDC, 25mA @32 VDC. ASX-13K Min., DSX-1.5K Min., DTX and DDX-1K Min., 2. 5 Amps to 125 Amps W62 Models: 24-240 VAC, W64 Models: 48-480 VAC,W66 Models: 48-600 VAC W62: 280 VAC, W64: 560 VAC, W66: 660 Up to 10 Amp Models: 50 mA, 25 Amp Models: 120 mA, 40 to 75 Amp Models: 250mA ,90 to 125 Amp, 500 mA, DDX 20 mA. 10 mA Max. Up to 50 Amp Models: 1.6 V, 75 to 125 Amp Models: 1.8 V, DDX 2.83 V. Up to 500 V/usec. ASX, DSX & DTX, 1/2 Cycle, (DDX) 600 uS Max. ASX, DSX & DTX, 1/2 Cycle, (DDX) 2.6 mS Max. (ASX, DSX & DDX) SPST-NO. (DTX) DPST-NO. 4000 VAC, DDX Models 2500 VAC. 1010 -40C to +80C -40C to +100C Greater than 100 Million Operations 2.5 to 50 Amp Models: 4 oz. (110 g) 75 Amp to 125 Amp Models: 6.8 oz. (192 g), 12 Amps, 25 Amps & 40 Amps, DDX Models: 4.76 oz. (135 g). OUTPUT Available from Your Local Magnecraft & Struthers- Dunn Distributors. * PART NUMBERS INPUT (Over Operating Temperature Range) OUTPUT (Over Operating Temperature Range) DC CONTROLLED AC OUTPUT CONTROL VOLTAGE RANGE W6202DSX-1 W6210DSX-1 *W6225DSX-1 W6240DSX-1 W6250DSX-1 W6275DSX-1 W6410DSX-1 W6425DSX-1 W6440DSX-1 W6450DSX-1 W6475DSX-1 Certified 3-32 VDC 3-32 VDC 3-32 VDC 3-32 VDC 3-32 VDC 3-32 VDC 3-32 VDC 3-32 VDC 3-32 VDC 3-32 VDC 3-32 VDC PART NUMBERS 3 VDC 3 VDC 3 VDC 3 VDC 3 VDC 3 VDC 3 VDC 3 VDC 3 VDC 3 VDC 3 VDC MIN DROP OUT 1 VDC 1 VDC 1 VDC 1 VDC 1 VDC 1 VDC 1 VDC 1 VDC 1 VDC 1 VDC 1 VDC NOMINAL VOLTAGE RANGE MAX. VOLTAGE 24-240 VAC 24-240 VAC 24-240 VAC 24-240 VAC 24-240 VAC 24-240 VAC 48-480 VAC 48-480 VAC 48-480 VAC 48-480 VAC 48-480 VAC 280 VAC 280 VAC 280 VAC 280 VAC 280 VAC 280 VAC 560 VAC 560 VAC 560 VAC 560 VAC 560 VAC CROSS REFERENCE MAX. CURRENT CRYDOM RATING 2.5 AMPS 10 AMPS 25 AMPS 40 AMPS 50 AMPS 75 AMPS 10 AMPS 25 AMPS 40 AMPS 50 AMPS 75 AMPS CONTROL VOLTAGE RANGE W6202ASX-1 W6210ASX-1 *W6225ASX-1 W6240ASX-1 W6250ASX-1 W6275ASX-1 W6410ASX-1 W6425ASX-1 W6440ASX-1 W6450ASX-1 W6475ASX-1 90 -280 VAC 90 -280 VAC 90 -280 VAC 90 -280 VAC 90 -280 VAC 90 -280 VAC 90 -280 VAC 90 -280 VAC 90 -280 VAC 90 -280 VAC 90 -280 VAC MAX PULL-IN MIN DROP OUT NOMINAL VOLTAGE RANGE MAX. VOLTAGE 90 VAC 90 VAC 90 VAC 90 VAC 90 VAC 90 VAC 90 VAC 90 VAC 90 VAC 90 VAC 90 VAC 10 VAC 10 VAC 10 VAC 10 VAC 10 VAC 10 VAC 10 VAC 10 VAC 10 VAC 10 VAC 10 VAC 24-240 VAC 24-240 VAC 24-240 VAC 24-240 VAC 24-240 VAC 24-240 VAC 48-480 VAC 48-480 VAC 48-480 VAC 48-480 VAC 48-480 VAC 280 VAC 280 VAC 280 VAC 280 VAC 280 VAC 280 VAC 560 VAC 560 VAC 560 VAC 560 VAC 560 VAC D2402 D2410 RSSD-10A EOM1DA44-4-32 D2425 RSSD-25A SSR240D25 D2440 RSSD-40A D2450 SSR240D50 D2475 SSR480D25 HD4850 SSR480D50 HD6075 CROSS REFERENCE MAX. CURRENT CRYDOM RATING 2.5 AMPS 10 AMPS 25 AMPS 40 AMPS 50 AMPS 75 AMPS 10 AMPS 25 AMPS 40 AMPS 50 AMPS 75 AMPS POTTER & BRUMFIELD IDEC INPUT (Over Operating Temperature Range) OUTPUT (Over Operating Temperature Range) AC CONTROLLED AC OUTPUT * MAX PULL-IN POTTER & BRUMFIELD IDEC A2402 A2410 RSSA-10A A2425 RSSA-25A A2440 RSSA-40A A2450 A2475 HA4825 HA4850 HA4875 SSR240A25 SSR240A50 SSR480A25 SSR480A50 - Certified PART NUMBERS INPUT (Over Operating Temperature Range) DC CONTROLLED AC OUTPUT CONTROL VOLTAGE RANGE W6690DSX-1 W66125DSX-1 3-32 VDC 3-32 VDC PART NUMBERS 3 VDC 3 VDC MIN DROP OUT NOMINAL VOLTAGE RANGE MAX. VOLTAGE 1 VDC 1 VDC 48-600 VAC 48-600 VAC 660 VAC 660 VAC INPUT (Over Operating Temperature Range) AC CONTROLLED AC OUTPUT CONTROL VOLTAGE RANGE W6690ASX-1 W66125ASX-1 90-280 VAC 90-280 VAC PART NUMBERS MAX PULL-IN MAX PULL-IN 90 VDC 90 VDC NOMINAL VOLTAGE RANGE 10 VDC 10 VDC 48-600 VAC 48-600 VAC INPUT (Over Operating Temperature Range) CONTROL VOLTAGE RANGE MAX PULL-IN MIN DROP OUT W6210DTX-1 W6225DTX-1 W6410DTX-1 3-32 VDC 3-32 VDC 3-32 VDC 3 VDC 3 VDC 3 VDC 1 VDC 1 VDC 1 VDC DC CONTROLLED DC OUTPUT W6212DDX-1 W6225DDX-1 W6240DDX-1 INPUT (Over Operating Temperature Range) CONTROL VOLTAGE RANGE 3.5 - 32 VDC 3.5 - 32 VDC 3.5 - 32 VDC MAX PULL-IN MIN DROP OUT 3.5VDC 3.5VDC 3.5VDC 1 VDC 1 VDC 1 VDC 90 AMPS 125 AMPS POTTER & BRUMFIELD CROSS REFERENCE MAX. MAX. CRYDOM VOLTAGE CURRENT RATING 660 VAC 660 VAC NOMINAL MAX. VOLTAGE RANGE VOLTAGE 90 AMPS 125 AMPS CROSS REFERENCE MAX. CURRENT RATING 12 AMPS 25 AMPS 40 AMPS POTTER & BRUMFIELD TD2410 SSRT240D10 - 10 AMPS 25 AMPS 10 AMPS OUTPUT (Over Operating Temperature R ange) 0 -200 VDC 0 -200 VDC 0 -200 VDC - HA6090 HA60125 OUTPUT (Over Operating Temperature Range) NOMINAL VOLTAGE RANGE POTTER & BRUMFIELD MAX. CURRENT RATING CRYDOM 280 VAC 280 VAC 500 VAC - HD6090 HD60125 OUTPUT (Over Operating Temperature Range) 24-240 VAC 24-240 VAC 48-480 VAC CROSS REFERENCE MAX. CURRENT RATING CRYDOM OUTPUT (Over Operating Temperature Range) MIN DROP OUT DC CONTROLLED AC TRIAC OUTPUT PART NUMBERS OUTPUT (Over Operating Temperature Range) CROSS CROSS REFERENCE REFERENCE CRYDOM D2D12 D1D20* D1D40* *Crydom relays only rated at 0-100 VDC PART NUMBERS DC CONTROLLED AC OUTPUT DPST NO W6210DTX-3 INPUT (Over Operating Temperature Range) CONTROL VOLTAGE RANGE MAX PULL-IN 3.5-32 VDC 3VDC MIN DROP OUT 1 VDC OUTPUT (Over Operating Temperature Range) NOMINAL VOLTAGE RANGE MAX. VOLTAGE MAX. CURRENT RATING 24-240 VAC 280 VAC 10 AMPS