HL
SPECIFICATIONS
15A (1C), 10 A (2C)
SPACE SAVING
POWER RELAY
HL RELAYS
mm inch
27.2
1.071
35.4
1.394
20.8
.819
FEATURES
• High switching capacity in a compact size
1 Form C (15 A 125 V AC), 2 Form C (10 A 250 V AC)
• Rugged construction for tough applications
• Long life
Mechanical: Min. 108 operations (DC),
Min. 5 × 107 operations (AC)
Electrical: Min. 5 × 105 operations
Contacts
#1 This value can change due to the switching frequency, environmental conditions,
and desired reliability level, therefore it is recommended to check this with the
actual load.
Remarks
* Specifications will vary with foreign standards certification ratings.
*1Measurement at same location as “Initial breakdown voltage” section
*2Detection current: 10 mA
*3Excluding contact bounce time
*4Half-wave pulse of sine wave: 11ms; detection time: 10µs
*5Half-wave pulse of sine wave: 6ms
*6Detection time: 10µs
*7Refer to 6. Conditions for operation, transport and storage mentioned in
AMBIENT ENVIRONMENT
Characteristics (at 25°C 77°F, 50% Relative humidity)
Arrangement 1 Form C 2 Form C
Initial contact resistance, max.
(By voltage drop 6 V DC 1 A) 50 mΩ
Contact material Silver alloy
Rating
(resistive)
Nominal switching
capacity
15 A 125 V AC,
10 A 250 V AC 10 A 250 V AC
Max. switching power AC: 2,500 VA
DC: 90 W
AC: 2,500 VA
DC: 90 W
Max. switching voltage 250 V AC
30 V DC
250 V AC
30 V DC
Max. switching current 15 A 10 A
Min. switching capacity#1 100 mA, 5 V DC
Expected
life
Mechanical (at 180 cpm) 5×107 (AC), 106 (DC)
Electrical
(resistive)
15 A 125 V
AC 5×105—
10 A 250 V
AC 5×1055×105
3 A 30 V DC 5×1055×105
Max. operating speed 20 cpm
Initial insulation resistance*1Min. 100 MΩ (at 500 V DC)
Initial
breakdown
voltage*2
Between contact sets 1,500 Vrms for 1 min.
Between open contacts 1,000 Vrms for 1 min.
Between contacts and coil 2,000 Vrms for 1 min.
Operate time (at nominal voltage) Max. 25 ms (DC type)
Max. 25 ms (AC type)
Release time*3 (without diode)
(at nominal voltage)
Max. 25 ms (DC type)
Max. 25 ms (AC type)
Temperature rise, max.
(at nominal voltage) Max. 80°C
Shock resistance Functional*4Min. 196 m/s2 {20 G}
Destructive*5Min. 980 m/s2 {100 G}
Vibration resistance
Functional*610 to 55 Hz
at double amplitude of 1 mm
Destructive 10 to 55 Hz
at double amplitude of 2 mm
Conditions for operation,
transport and storage*7
(Not freezing and
condensing at low
temperature)
Ambient
temperature
–50°C to +70°C
–58°F to +158°F
Humidity 5 to 85% R.H.
Unit weight Approx. 35 g 1.25 oz
TYPICAL APPLICATIONS
Power station control equipment,
refrigerators, building control equipment,
office machines, and medical equipment.
ORDERING INFORMATION
2HHLEx.
Contact arrangement
AC240V
Terminal arrangement Coil voltage
Note: Standard packing Carton: 20 pcs., Case: 200 pcs.
UL/CSA approved type is standard.
1: 1 Form C
2: 2 Form C
H: Plug-in
HP: PC board
HTM: Top mounting
L: Light emitting diode wired, plug-in
PL: Light emitting diode wired, PC board
AC 6, 12, 24, 48,
120, 240 V
DC 6, 12, 24, 48,
110 V
All Rights Reserved © COPYRIGHT Matsushita Electric Works, Ltd.