220W AC-DC High Reliability Industrial Adaptor GST220A ser ie s















File Name:GST220A-SPEC 2016-03-16



















{

 
SPECIFICATION
GST220A ser ie s
ORDER NO.
DC VOLTAGE Note.2
SAFETY MODEL NO.
RATED CURRENT
CURRENT RANGE
RATED POWER (max.)
RIPPLE & NOISE (max.) Note.3
OUTPUT
VOLTAGE RANGE Note.7
FREQUENCY RANGE
POWER FACTOR (Typ.)
EFFICIENCY (Typ.)
AC CURRENT (Typ.)
INPUT
ENVIRONMENT
INRUSH CURRENT (max.)
LEAKAGE CURRENT(max.)
SAFETY STANDARDS
SAFETY &
EMC
(Note. 8)
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
MTBF
DIMENSION
OTHERS
NOTE
PACKING
PROTECTION
GST220A15
GST220A15-R7B
GST220A12
GST220A12-R7B
GST220A20
GST220A20-R7B
GST220A24
GST220A24-R7B
GST220A48
GST220A48-R7B
15V12V 20V 24V 48V
100mVp-p80mVp-p 150mVp-p 180mVp-p 240mVp-p
VOLTAGE TOLERANCE Note.4
LINE REGULATION Note.5
LOAD REGULATION
±5.0%±5.0% ±4.0% ±3.0% ±2.0%
±1.0%±1.0% ±1.0% ±1.0% ±1.0%
±5.0%±5.0% ±4.0% ±3.0% ±2.0%
85 ~ 264VAC 120 ~ 370VDC
47 ~ 63Hz
PF>0.91 / 230VAC PF>0.98 / 115VAC at full load
90%90% 92% 93.5% 94.5%
4A / 115VAC 2A / 230VAC
120A / 230VAC
0.75mA / 240VAC
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
I/P-O/P: 3KVAC I/P-FG: 2KVAC O/P-FG:SHORT
I/P-O/P:100M Ohms / 500VDC / 25/ 70% RH
209.4K hrs min. MIL-HDBK-217F(25)
-30 ~ +70 (Refer to "Derating Curve")
20% ~ 90% RH non-condensing
-40 ~ +85, 10 ~ 95% RH
±0.03% / (0~50)
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
210*85*46mm (L*W*H)
1.1Kg; 12pcs/14.2Kg/0.96CUFT
CONNECTOR
PLUG
CABLE See page 3 ; Other type available by customer requested
See page 3 ; Other type available by customer requested








For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.
(as available on http://www.meanwell.com)
Compliance to EN61000-4-2,3,4,5,6,8,11, light industry level, criteria A
OVERLOAD
OVER VOLTAGE
105 ~ 135% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
105 ~ 135% rated output voltage
13.4A15A 11A 9.2A 4.6A
0 ~ 13.4A0 ~ 15A 0 ~ 11A 0 ~ 9.2A
0 ~ 4.6A
201W180W 220W 221W 221W
SETUP, RISE TIME Note.6
HOLD UP TIME (Typ.)
2000ms, 50ms / 230VAC 2000ms, 50ms / 115VAC at full load
20ms / 230VAC 20ms / 115VAC at full load
OVER TEMPERATURE Shut down o/p voltage, recovers automatically after temperature goes down
EMC IMMUNITY
EMC EMISSION
220W AC-DC High Reliability Industrial Adaptor
Protection type : H mode iccup @ 10%load
File Name:GST220A-SPEC 2016-03-16
UL60950-1, CSA C22.2, TUV EN60950-1, BSMI CNS14336, CCC GB4943, PSE J60950-1,AS/NZS 60950.1 approved
Compliance to EN55022 class B, EN61000-3-2,3, FCC PART 15 / CISPR22 class B, CAN ICES-3(B)/NMB-3(B),CNS13438 class B, GB9254, GB17625.1
Derating Curve Static Characteristics
Mechanical Specification
Installation Manual
Please refer to : http://www.meanwell.com/webnet/search/InstallationSearch.html
Plug Assignment
POWER LED
46
85
210
30±3mm
UL2464 16AWGx4C 1000±50mm
1
2
4
3
AMBIENT TEMPERATURE ()
LOAD (%)
0-30 2010 30 40
20
40
80
60
100
6050 70
INPUT VOLTAGE (VAC) 60Hz
85 10090 120110 160140 200180 240220 264
LOAD (%)
90
100
80
70
60
50
40
(HORIZONTAL)
50
230VAC
100VAC for others
110VAC for 12~15V For 12~15V
For others
GST220A ser ie s
Case No. 961A Unit:mm
220W AC-DC High Reliability Industrial Adaptor
R7B
PIN NO.
1,4
2,3
OUTPUT
+V
-V
23
14
AC FG
-V connected to AC FG
Output plug (Power DIN 4 pin with lock type) : KYCON KPPX-4P equivalent
Mating plug (customer side , not provide with power supply) : KYCON KPJX-CM-4S equivalent
File Name:GST220A-SPEC 2016-03-16
Mouser Electronics
Authorized Distributor
Click to View Pricing, Inventory, Delivery & Lifecycle Information:
Mean Well:
GST220A15-R7B GST220A20-R7B GST220A24-R7B GST220A12-R7B GST220A48-R7B