AIM & THURLBY THANDAR INSTRUMENTS
6GHz RF signal generator - CW with sweep
TGR6000
10MHz to 6,000MHz at -110Bm to +7dBm
High purity output with low phase noise
Custom level trim of up to 100 points
Fast full-range sweep using step or list modes
Remote control via RS232, USB, GPIB and LAN interfaces
aimtti.com
aimtti.co.uk | aimtti.us
TGR6000 - 6GHz RF signal generator for CW and swept/stepped CW applications
10MHz to 6000MHz frequency range
Accuracy better than 1ppm over 15oC to 30oC
Ageing better than 1 ppm over one year
External frequency reference input
Low phase noise and low leakage
-110dBm to +7dBm amplitude, 0.1dB steps
Amplitude entry in dBm, µV / mV, or dBµV
User compensation tables for specific test set-ups
Fast stepping sweep with dwell times down to 10ms
Internal or externally triggered sweep, lin or log, up or down
List sweep of up to 1000 points of amplitude vs frequency
Storage for 12 generator set-ups and 16 sweep lists
Compact half-rack 2U casing uses minimum bench space
Full remote control through RS232, USB, LAN or GPIB
Significantly lower cost than other 6GHz generators
Cost Effective Solution
The TGR6000 is a low-cost RF signal generator with a maximum frequency of
6GHz. It is intended for CW (carrier wave) applications where modulation is
not required, and avoids the costs associated with adding modulations.
Low phase noise is matched by low leakage, low residual FM and spurii. The
internal timebase has a 1ppm stability, and an external frequency reference
can be used for higher precision.
Flexible Sweep Modes
The TGR6000 incorporates an advanced stepped sweep system which allows
both frequency and amplitude to be swept.
The sweep can be defined in terms of start and stop frequency/amplitude
points with linear or logarithmic interpolation between them. The total
number of points can be set from 2 to 1000 and the dwell time between points
can be set from 10ms up to 10s.
Sweeps can be triggered manually, from an internal timer or from the remote
interfaces. If required, each point within the sweep can be stepped via a
trigger event rather than a fixed time.
In List Sweep mode, the sweep is defined by a table of up to 1000 frequency/
amplitude points which can be stepped between either by trigger events or by
an individual dwell time for each point.
This system provides the flexibility to generate changes in frequency and
amplitude to match virtually any required test pattern.
Lists can be generated within the instrument, or on a PC and downloaded
via the interfaces. Up to 16 user lists can be stored permanently within the
instrument’s memory.
User Compensation Table (Trim)
The Trim function enables the output level to be adjusted in order to calibrate
an entire test set up.
The Trim function consists of a user programmable list of up to 100 amplitude
adjustment /frequency pairs. When turned on, it adjusts the output level by an
amount linearly interpolated between the frequencies specified in the list.
Ease of Use
The TGR6000 is both simple and intuitive to use.
Frequency and level can be entered directly from the keyboard in whichever
units are preferred. Alternatively values can be changed in user defined
increments using the spin wheel or up/down keys.
The four line display has
soft key functionality for
setting up more complex
functions such as sweep
lists.
Set-up and Sweep List Storage
The generator has internal storage for up to 12 complete instrument
set-ups and up to 16 sweep lists.
Set-ups and sweep lists can be given user defined names if required.
Full Remote Control
The TGR6000 incorporates full remote control using USB, RS-232, GPIB and
LAN (Ethernet) interfaces.
Compact for Bench or Rack
The generator is housed in
a 2U high half-rack width
case the uses the minimum
of bench space.
A rack mounting kit is
available.
TGR6000 - Technical Specifications
Designed and built in Europe by:
Thurlby Thandar Instruments Ltd.
Glebe Road, Huntingdon, Cambridgeshire. PE29 7DR United Kingdom
Tel: +44 (0)1480 412451 Fax: +44 (0)1480 450409
Email: sales@aimtti.com Web: www.aimtti.com
Brochure Part No. 82100-1430 Iss.1A
FREQUENCY SPECIFICATION
Frequency Setting
Frequency Range: 10MHz to 6000MHz
Setting Resolution: 10Hz
Accuracy/Stability: See Reference Frequency section.
Phase Noise
500MHz Carrier: <-110dBc/Hz (typ) @ 20kHz offset
<-120dBc/Hz (typ) @ 100kHz offset
3GHz Carrier: <-95dBc/Hz (typ) @ 20kHz offset
<-110dBc/Hz (typ) @ 100kHz offset
6GHz Carrier: <-89dBc/Hz (typ) @ 20kHz offset
<-104dBc/Hz (typ) @ 100kHz offset
Residual FM
Residual FM: 12 Hz @ 500MHz
Equivalent peak deviation in a 300Hz to 3.4kHz bandwidth.
Switching Speed
Settling Time: <8ms to settle within 100Hz or 0.1ppm of final frequency, if greater.
FREQUENCY REFERENCE
Internal Reference
Reference Accuracy: <± 1ppm, 15ºC to 30ºC
<± 2ppm, 5ºC to 40ºC
Reference Stability: <1ppm/year
10MHz Reference In/Out
Rear panel BNC that can be disabled when not required for input or output.
Ext. Reference In: 10MHz, 50W input impedance, 2 to 5Vpp
Automatic detection and selection when external reference signal is
present and Reference IN is selected from front panel.
Front panel indicator shows when External Reference is active.
Int. Reference Out: 10MHz, 50W output impedance, >2Vpp into 50W
Signal present when Reference OUT is selected from front panel.
OUTPUT LEVEL
Level Setting
Level Range: –110dBm to +7dBm
Setting Parameters: dBm, dBµV or µV/mV
Setting Resolution: 0.1dB, 0.01uV to 1mV
Setting Accuracy: ± 2dBm
Signal Purity
Harmonically Related: <-25dBc @ +7dBm, <-30dBc@levels <=0dBm 30 to 6000MHz
<-25dBc@levels <=0dBm 10 to 30MHz
Sub-harmonic: <3000MHz : None. >3000MHz :<–40dBc (typ) @ +7dBm
Non-harmonic Spurii: <–50dBc >10kHz offset 10 to 3000MHz (Note 1)
<-44dBc >10kHz offset 3000MHz to 6000MHz (Note 2)
Note 1 - <-45dBc >10kHz offset 1900–2150MHz
Note 2 - <-39dBc >10kHz offset 3800–4300MHz.
Output Connection
Output Impedance: 50W
Output Connector: Type N
Reverse Protection: 50V DC
Output Switch: RF OUT On/Off switch with indication of ON status
FREQUENCY and AMPLITUDE SWEEP
Step Sweep
Step frequency and/or amplitude according to a formula over a specified number of points.
Max Points: 1000
Formula Specifies: Frequency start/stop. Amplitude start/stop.
Dwell time at each step – programmable 0.01 to 10.000sec
Sweep Run: Continuous or single. Sweep up or down
Step Spacing: Linear or logarithmic
Sweep Triggering: Manual, Ext. signal, timed (0.1 – 999.9sec) or via remote interface.
Sync Signal: (Output Stable) available during dwell time.
Programmable to be high or low
List Sweep
As for Step Sweep except that a user defined table of frequency, amplitude and dwell time values
defines the steps. The table can be created within the instrument or downloaded via the remote
interfaces.
Max Points: 1000
List Storage: Up to 16 Sweep Lists can be stored permanently within the instrument
Point Trigger
Each point in a sweep (step or list) can be subject to a trigger event rather than a dwell time.
Point Triggering: Manual, Ext. signal or via remote interface.
TRIM (User Level Compensation Tables)
A table of frequency/gain pairs allows the user to modify the generator output level with respect to
frequency to calibrate an entire test set up or improve the calibration of the generator alone. The
table can be created within the instrument or downloaded via the remote interfaces.
Max. Points: 100
OTHER INPUTS/OUTPUTS
TRIG IN
DC coupled External Trigger Input signal used for step Sweep changes in Point Trigger mode.
Input Threshold: 1.65V nominal.
Trigger polarity can be set to Negative Edge or Postive Edge.
Input Protection: Maximum/minimum external applied voltage is +6V or –1V.
SYNC Out
Rear panel output SYNC signal goes to its active state when generator output frequency & level have
settled within specification after a step change during Sweep. SYNC returns to inactive state at end
of specified dwell period.
Active Output Level: +5V (Active state set to ‘Pos’) or 0V (Active state set to ‘Neg’)
Output Impedance: 50W Minimum load impedance is also 50W.
Output Protection: Output will withstand accidental short circuit to ground and applied
external voltages up to +5V.
DIGITAL INTERFACES
Full digital remote control facilities are available through the RS232, USB, LAN and GPIB interfaces.
RS-232
9-pin D connector. Variable Baud rate can be set between 1200 and 115200 Baud maximum.
USB
USB 2.0 connection (backwards compatible with USB 1.x). Operates as a virtual COM port.
GPIB (IEEE-488)
The interface conforms with IEEE-488.1 and IEEE-488.2.
Ethernet (LAN)
Standard 10/100 base-T hardware connection. ICMP and TCP/IP Protocol for connection to Local
Area Network or direct connection to a single PC.
GENERAL SPECIFICATIONS
Input
AC Input: 110-240VAC ±10% 50/60Hz; 100-120VAC ±10% 400Hz; 60VA max.
Installation Category II.
Temperature & Environmental
Operating Range: +5ºC to +40ºC, 20% to 80% RH
Storage Range: -20ºC to + 60ºC
Environmental: Indoor use at altitudes up to 2000m, Pollution Degree 2.
Safety & EMC
Safety: Complies with EN61010-1
EMC: Complies with EN61326
Front Panel Display and Setting
Display: 20 character x 4 row backlit alphanumeric LCD
Data Entry: Keyboard selection of all major parameters. Value entry by character scroll
using rotary control or up/down keys, or value stepping in user-selected
increment values using rotary control or up/down keys
Stored Settings: Up to 12 complete set-ups. Up to 16 sweep lists
Physical
Location: Built-in tilt feet for bench-top use. Rack mountable with optional mount.
Size: 86.5mm (2U) height; 213.5mm (½-rack) width; 350mm long .
Weight: 3.65kg (8lb).
OPTIONS
Rack Mount
19 inch rack mount for one or two instruments.
Thurlby Thandar Instruments Ltd. operates a policy of continuous development and reserves the right to
alter specifications without prior notice.
Thurlby Thandar Instruments Ltd.
Glebe Road, Huntingdon, Cambridgeshire PE29 7DR England (United Kingdom)
Tel: +44 (0)1480 412451 Fax: +44 (0)1480 450409
Email: info@aimtti.com Web: www.aimtti.com
Designed and built in Europe by:
Company name and product brands
Thurlby Thandar Instruments Ltd. (TTi) is one of Europe’s leading
manufacturers of test and measurement instruments.
Products have been sold under two brand names:
TTi and Aim.
In the future, however, the full product range will be branded Aim-TTi.
This changeover will be gradual and many products will continue to carry
the TTi or Aim brands for some time to come.
Web Addresses (URLs)
The preferred URL for obtaining information concerning Aim-TTi products
is:
www.aimtti.com (international customers)
Customers in the UK should use the URL:
www.aimtti.co.uk
Customers in the USA should use the URL:
www.aimtti.us
Note that previous URLs such as www.tti-test.com will continue to operate
for the time being.
Product Summary
Laboratory Power Supplies
Bench and system power supplies from 30 watts up to
1200 watts using linear, mixed-mode and PowerFlex
regulation technologies.
Waveform Generators
Analog and digital (DDS) function generators, true
arbitrary generators, arbitrary/function generators and
pulse generators.
Precision Measurement Instruments
Benchtop DMMs, frequency counters, component
measurement instruments (LCR), electronic dc loads,
current probes.
RF and EMC Test Equipment
Spectrum analyzers, signal generators, frequency counters,
power meters, emc measurement instruments.