PHOENIX CONTACT Deutschland GmbH Page 1 / 5
http://www.phoenixcontact.de Feb 2, 2011
Extract from the online
catalog
CN-LAMBDA/4-5.9-SB
Order No.: 2800023
http://eshop.phoenixcontact.de/phoenix/treeViewClick.do?UID=2800023
Attachment plug with Lambda/4 technology as surge protection for
coaxial signal interfaces. Connection: N connectors male/female
connector
Commercial data
GTIN (EAN)
4 046356 410083
sales group J401
Pack 1 pcs.
Customs tariff 85363010
Catalog page information Page 171 (TT-2009)
Product notes
WEEE/RoHS-compliant since:
04/09/2008
http://
www.download.phoenixcontact.com
Please note that the data given
here has been taken from the
online catalog. For comprehensive
information and data, please refer
to the user documentation. The
General Terms and Conditions of
Use apply to Internet downloads.
Technical data
General
Housing material Brass (CuZn)
Color nickel
Total surge current (8/20) µs 60 kA
Total surge current (10/350) µs 20 kA
CN-LAMBDA/4-5.9-SB Order No.: 2800023
http://eshop.phoenixcontact.de/phoenix/treeViewClick.do?UID=2800023
PHOENIX CONTACT Deutschland GmbH Page 2 / 5
http://www.phoenixcontact.de Feb 2, 2011
Ambient temperature (operation) -40 °C ... 90 °C
Mounting type Connection-specific intermediate plugging
Design Attachment plug
Degree of protection IP68
Direction of action Line-Shield/Earth Ground
Width 26.10 mm
Height 65.00 mm
Length 38.00 mm
Protective circuit
IEC category C2
C3
D1
VDE requirement class C2
C3
D1
Nominal current IN5 A (25°C)
Nominal discharge surge current In (8/20) µs
(Core-Earth)
50 kA
Nominal discharge surge current In (8/20) µs
(Core-Shield)
50 kA
Total surge current (8/20) µs 60 kA
Max. discharge surge current Imax (8/20) µs
maximum (Core-Earth)
60 kA
Max. discharge surge current Imax (8/20) µs
maximum (Core-Shield)
60 kA
Lightning test current (10/350) µs, peak value limp ≤ 20 kA
Output voltage limitation at 1 kV/µs (Core-Earth)
spike
≤ 11 V (6 kV/3 kA)
Output voltage limitation at 1 kV/µs (Core-Shield)
spike
≤ 11 V (6 kV/3 kA)
Output voltage limitation at 1 kV/µs (Core-Earth)
static
≤ 11 V (6 kV/3 kA)
Output voltage limitation at 1 kV/µs (Core-Shield)
static
≤ 11 V (6 kV/3 kA)
Protection level UP (Core-Earth) ≤ 11 V (6 kV/3 kA)
Protection level UP (Core-Shield) ≤ 11 V (6 kV/3 kA)
Input attenuation aE, asym. Typ. 0.05 dB (≤ 0.15 dB)
Frequency range 2.4 GHz ... 5.9 GHz
CN-LAMBDA/4-5.9-SB Order No.: 2800023
http://eshop.phoenixcontact.de/phoenix/treeViewClick.do?UID=2800023
PHOENIX CONTACT Deutschland GmbH Page 3 / 5
http://www.phoenixcontact.de Feb 2, 2011
Standing wave ratio SWR in a 50 Ω system Typ. 1.1 (≤ 1.20 (2.4 GHz...5.9 GHz))
Permissible HF power Pmax. at SWR=xx (50 Ohm
system)
≤ 500 W
≤ 4 kW (peak)
Surge carrying capacity in acc. with IEC 61643-21
(Core-Earth)
C2 (10 kV/5 kA)
D1 (2.5 kA)
Surge carrying capacity in acc. with IEC 61643-21
(Core-Shield)
C2 (10 kV/5 kA)
D1 (2.5 kA)
Connection data
Type of connection N Connector
Connection type IN N connector, male
Connection type OUT N connector, female
Connection, protective circuit
Standards/regulations IEC 61643-21
Certificates / Approvals
Certification GOST
Accessories
Item Designation Description
Assembly
2818135 CN-UB/MP Tongue for attaching the CN-UB..., to housing panels, for
example.
2803137 CN-UB/MP-90DEG-50 Angled bracket for individually fixing CN-UB... to housing panels,
for example.
CN-LAMBDA/4-5.9-SB Order No.: 2800023
http://eshop.phoenixcontact.de/phoenix/treeViewClick.do?UID=2800023
PHOENIX CONTACT Deutschland GmbH Page 4 / 5
http://www.phoenixcontact.de Feb 2, 2011
Additional products
Item Designation Description
Assembly
2818135 CN-UB/MP Tongue for attaching the CN-UB..., to housing panels, for
example.
Diagrams/Drawings
Circuit diagram
CN-LAMBDA/4-5.9-SB Order No.: 2800023
http://eshop.phoenixcontact.de/phoenix/treeViewClick.do?UID=2800023
PHOENIX CONTACT Deutschland GmbH Page 5 / 5
http://www.phoenixcontact.de Feb 2, 2011
Address
PHOENIX CONTACT Deutschland GmbH
Flachsmarktstr. 8
32825 Blomberg,Germany
Phone +49 5235 3 12000
Fax +49 5235 3 41200
http://www.phoenixcontact.de
© 2010 Phoenix Contact
Technical modifications reserved;