Controlled by microprocessor
2/8 stage charging selectable on output panel
Universal AC input / Full range
Built-in active PFC function PF>0.95
Protection: Reverse Polarity / Short circuit / Over voltage / Over temperature
Charger for lead-acid batteries
3 color LED loading indicator
2-Bank charger
Temperature compensation function
FAN on/off control (depends on charging current)
3 years warranty
Built-in remote ON-OFF control
Features :
SPECIFICATION
PB-1000-12 PB-1000-24 PB-1000-48
MODEL
BOOSTCHARGEVOLTAGE
FLOATCHARGEVOLTAGE
BATTERY TYPE
LEAKAGECURRENTFROM
BATTERY (Typ.)
RECOMMENDEDBATTERY
CAPACITY(AMP HOURS)(Note3)
OUTPUT
VOLTAGERANGE
FREQUENCY RANGE
EFFICIENCY (Typ.)
POWERFACTOR(Typ.)
INPUT
ENVIRONMENT
INRUSHCURRENT (Typ.)
LEAKAGECURRENT
OVERTEMPERATURE
SHORTCIRCUIT
REVERSEPOLARITY
SAFETY STANDARDS
HARMONICCURRENT
EMICONDUCTION&RADIATION
SAFETY &
EMSIMMUNITY
EMC
(Note2)
WITHSTANDVOLTAGE
ISOLATIONRESISTANCE
WORKINGTEMP.
WORKINGHUMIDITY
STORAGETEMP.,HUMIDITY
TEMP.COEFFICIENT
VIBRATION
OVERVOLTAGE
PROTECTION
ACCURRENT (Typ.)
14.4V 28.8V 57.6V
13.8V
Open&SealedLead Acid
<1mA
200~600Ah
27.6V 55.2V
34.7A 17.4A
120~350Ah 60~175Ah
90~264VAC127~370VDC
47~63Hz
85%
0.95/230VAC0.98/115VACatfullload
88% 89%
12A/115VAC5.2A/230VAC
25A/115VAC50A/230VAC
<3.5mA /240VAC
16~18V 32~35V 64.5~69.5V
Protectiontype:Shutdowno/pvoltage,re-powerontorecover
80 5 (12V),85 5 (24V,48V)(TSW1:detectonheatsinkofpowertransistor)
85 5 (12V),75 5 (24V,48V)(TSW2:detectonheatsinkofo/pdiode)
Protectiontype:Shutdowno/pvoltage,recoversautomaticallyaftertemperaturegoesdown
YES,protectedbyinternalcircuit
YES,protectedbyinternalcircuit
UL60950-1, TUVEN60950-1approved
CompliancetoEN55022(CISPR22)
Complianceto EN61000-3-2,-3
CompliancetoEN61000-4-2,3,4,5,6,8,11;ENV50204,EN55024,lightindustrylevel,criteria A
I/P-O/P:3KVACI/P-FG:1.5KVACO/P-FG:0.5KVAC
I/P-O/P,I/P-FG,O/P-FG:100MOhms/500VDC /25 /70%RH
-20~+60 (Refertooutputloadderatingcurve)
20~90%RHnon-condensing
-40~+85 ,10~95%RH
0.05%/ (0~50 )
10~500Hz,2G10min./1cycle,60min.eachalongX, Y,Zaxes
MTBF 127.4Khrsmin.MIL-HDBK-217F(25 )
300*184*70mm(L*W*H)
DIMENSIONOTHERS
NOTE
PACKING 3.5Kg;4pcs/15Kg/1.83CUFT
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
3. This is Mean Well's suggested range. Please consult your battery manufacturer for their suggestions about maximum charging current limitation.
PB-1000 series
1000WIntelligentSingleOutputBatteryCharger
FUNCTION
REMOTECONTROL
BATTERBANKS
FASTCHARGE
OUTPUTOK
TEMPERATURECOMPENSATION
CHARGEROK
Open:NormalworkShort:StopCharging
2banks(A &B)
2/8stageselectable
Relaycontactrating(max.):30V/1A resistive;"Short"whenthebatteryisfull,"Open"whenthebatteryisstillcharging
Relaycontactrating(max.):30V/1A resistive;"Short"whentheunitisworkingproperly,"Open"whentheunitisfailureortheprotectionfunctionisactivating
ByNTC,compensatebothbanksatthesametime
FileName:PB-1000-SPEC2009-04-09
..
OUTPUTCURRENT 60A
MechanicalSpecification
FileName:PB-1000-SPEC2009-04-09
CaseNo.804BUnit:mm
ChargingCurve
ChargeCurrent
ChargeCurrent
ConstantCurrent
stage1
stage1 stage2 stage3 stage4 stage5 stage6 stage7 stage8
stage2 BatteryFull
ConstantVoltage
Start
2Stage
ChargeVoltage
ChargeVoltage
100%
10%
boostV
PinNo. PinNo.
5,6
7
9
10
3,4
RY13:Bank A OKNTC/GND: Temperaturesense
RY14:BankBOK
RY15:ChargerOK
RC+/RC-:RemoteON/OFF
1,2 8
Assignment Assignment
RY15
GND
RY14
RY13
MatingHousing Terminal
orequivalent orequivalent
ControlPinNo. Assignment(CN100):HRSDF11-10DP-2DS orequivalent
HRSDF11-10DS
HRSDF11-**SC
RC-
RC+
NTC(5K )
8Stage
Pulse SoftStart ConstantCurrent ConstantVoltage Analysis Recondition Float Maintain
Airflow
direction
ACINPUT
INLET
ON
OFF
72.6
10
155
7
300
70
A
48
26.5
A
70 22 22
184
SWITCH
ON/OFF
A
BA
B
1
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
9
9
1
1
0
0
8Stage
8Stage
2Stage
2Stage
Orange
Orange
Green
Green
ColorofLED
ColorofLED
PB-1000 series
1000WIntelligentSingleOutputBatteryCharger
FileName:PB-1000-SPEC2009-04-09
PB-1000 series
BlockDiagram
CONTROL
CONTROL
DETECTION
DETECTION
SWITCHING
POWER
ACTIVE
INRUSH
CURRENT
LIMITING
RECTIFIER
&
PFC
PFC
CONTROL
AUX
POWER
MCU
FAN
OTP
PWM
REMOTE
Bank A OK
BankBOK
ChargerOK
REVERSE
CURRENT
FILTER
&
RECTIFIER BANK A (+V)
BANKB(+V)
2/8
STAGE
SELECT
RC
RY13
RY14
RY15
I/P FILTER
EMI
PFC:95KHz
PWM fosc:60KHz
FunctionDescriptionofCN100
PinNo. Function Description
1,2
3,4
5,6
7,8
9,10
RY13 Relaycontactrating(max.):30V/1A resistive.;"Short"whenthebattery A isfull, "Open"whenthebattery A isstillcharging.
Relaycontactrating(max.):30V/1A resistive.;"Short"whenthebatteryBisfull, "Open"whenthebatteryBisstillcharging.
Relaycontactrating(max.):30V/1A resistive.;"Short"whentheunitisworkingproperly, "Open"whentheunitisfailureor
Temperaturesensorcomesalongwiththechargercanbeconnectedtotheunittoallow temperaturecompensationofthe
Turntheoutputonandoffbyelectricalordrycontactbetweenpin10(RC+)andpin9(RC-),"Open":Normalwork,
"Short":Stopcharging
theprotectionfunctionisactivating.
chargingvoltage.
Ifthetemperaturesensorisnotused,thechargerstillworksnormally.
RY14
RY15
GND/RTH
RC-/RC+
1000WIntelligentSingleOutputBatteryCharger
TheFunctionofLEDs
Battery ColorofLED
Fail
Charging
BatteryFull
Red
Orange
Green
DeratingCurve
AMBIENTTEMPERATURE( )
LOAD(%)
20
40
60
80
100
-20 0 10 20 30 40 50 60 70 (HORIZONTAL)
BetweenRC+(pin10)andRC-(pin9)
SWOpen
SWShort
Charger
ON
OFF
ThechargercanbeturnedON/OFFbyusingthe
Thechargermaybehookeduptwobatterybanks(A and/orB).Connectthebatterybank(s)asbelow.Ifyouareconnecting2batterybanksinthe
sametime,keepinmindthattheymustshareacommonground.
"RemoteControl"function.
SW
910
CN100
RY13
RY14
RY15
GND
RC-
RY13
RY14
RY15
RTH
RC+
12
FileName:PB-1000-SPEC2009-04-09
PB-1000 series
FunctionManual
1.RemoteControl
2.TwoBatteryBanks
A
A A
B
B B
8Stage
8Stage 8Stage
++
+ +
Battery ABatteryB
Battery A BatteryB
--
- -
2Stage
2Stage 2Stage
AB
8Stage
++
Battery ABatteryB
--
2Stage
1000WIntelligentSingleOutputBatteryCharger
A
AA
A
B
BB
B
1
11
1
2
22
2
3
33
3
4
44
4
5
55
5
6
66
6
7
77
7
8
88
8
9
99
9
1
11
1
0
00
0
Switch
Turnright
Turnleft
Chargingmode
2stagecharging
8stagecharging
Thechargerfeaturesuserselectable2or8stagecharging.
Thechargingprofileisselectedbymovingtheslideswitch
onthebackpanel.
3.2or8stageChargingSelect
Charger
Bank A
BankB
1.Bank A OK(RY13)
2.BankBOK(RY14)
Normalwork
Failureortheprotection
functionisactivating
Betweenpin5andpin6(RY15)
Betweenpin1andpin2(RY13) ColorofLED A
ColorofLEDBBetweenpin3andpin4(RY14)
ON(Short)
ON(Short) Green
GreenON(Short)
OFF(Open)
OFF(Open) Orange
OrangeOFF(Open)
4.ChargerOKRelay(RY15)
5.OutputOKRelay(RY13&RY14)
9
9
9
10
10
10
CN100
CN100
CN100
RY13
RY13
RY13
RY14
RY14
RY14
RY15
RY15
RY15
GND
GND
GND
RC-
RC-
RC-
RY13
RY13
RY13
RY14
RY14
RY14
RY15
RY15
RY15
RY14
RY13
RY15
RTH
RTH
RTH
RC+
RC+
RC+
1
1
1
2
2
2
FileName:PB-1000-SPEC2009-04-09
PB-1000 series
AB
8Stage
++
Battery ABatteryB
--
2Stage
AB
8Stage
++
Battery ABatteryB
--
2Stage
AB
8Stage
++
Battery ABatteryB
--
2Stage
AB
8Stage
++
Battery ABatteryB
--
2Stage
Temperaturesensorcomesalongwiththechargercan
6.TemperatureCompensation
beconnectedtotheunittoallowtemperaturecompensation
ofthechargingvoltage.
Ifthetemperaturesensorisnotused,thechargerstill
worksnormally.
CN100
NTC
Thetemperaturesensorcaneitherbeattachedtothe
batteryorplacedinitssurroundingenvironment.
RY13
RY14
RY15
GND
RC-
RY13
RY14
RY15
RTH
RC+
12
910
Battery A Full
Charging
BatteryBFull
Charging
1000WIntelligentSingleOutputBatteryCharger
A
A
A
A
B
B
B
B
1
1
1
1
2
2
2
2
3
3
3
3
4
4
4
4
5
5
5
5
6
6
6
6
7
7
7
7
8
8
8
8
9
9
9
9
1
1
1
1
0
0
0
0
8Stage 2Stage