Rated Voltage (max): 250 VAC
Operating Frequency: 50/60 Hz
Rated Current: 10 to 300A
Test Voltage (two seconds): 5000 VDC
Capacitor Class (EN133200): Designed to meet Y2
Pulse Test (EN133200): 5000V Peak
Insulation Resistance (within 1 minute):
For C < 0.33F, R> 15000M
For C > 0.33F, RC(M*F)>5000s
Operating Ambient Temperature Range
(at rated current Ir):
10 to 100A: -40°C to +60°C
200A: -40°C to +50°C
250 & 300A: -40°C to +40°C
Category Temperature Range: -40°C to +85°C
Current Derating Above Ambient:
10-100A: For temperature,
= R (85-)/25
200A: For temperature,
= R (85-)/35
250 & 300A: For temp.,
= R (85-)/45
Climatic Category: 40/85/21
MTBF: > 5 million hours typical
Insulating Materials Flammability Rating: UL94V-0
Case & Terminal Material: Nickel Plated Brass
Corcom Product Guide
FFA Series
228
FFA Series
AC Feedthrough Filters – Class Y2
Dimensions are in inches and millimeters unless otherwise specified. Values in italics
are metric equivalents. Dimensions are shown for reference purposes only.
Specifications subject to change.
Catalog: 1654001
Issue Date: 06.2011
For email, phone or live chat, please go to
te.com/help
corcom.com
Component Recognized by
UL to US and Canadian Requirements
• AC feedthrough filters
• Current Ratings from 10 to 300A
• Designed to meet the very stringent safety
requirements of EN133200 class Y2 including
the 5000V pulse test
• Custom versions available
Ordering Information
10 FFA6 – BA
Filter ID
See Table
FFA Series Screw Terminals
Current Rating (in A)
Specifications
Electrical Schematic
Filter
ID Value (nF)
Inductance
(nH)
Max.
Leakage
Current
(mA)*
DC
Resistance
(m) Max.
BA 2 x 4.7 70 0.9 6
CA 2 x 10 70 1.9 4
CE 2 x 10 140 1.9 7
DG 2 x 22 170 4.2 4
DH 2 x 22 180 4.2 4
GB 2 x 47 80 8.9 3
GJ 2 x 47 210 8.9 9
HC 2 x 100 90 19 2
HD 2 x 100 120 19 1
HF 2 x 100 160 19 < 1
HN 2 x 100 250 19 6
JK 2 x 150 240 29 3
NP 2 x 470 330** 89 < 2
PP 2 x 1000 330 188 < 2
Filter Options / Specifications