154N Compensated
PERFORMANCE SPECIFICATIONS
Supply Current: 1.5mA
Ambient Temperature: 25°C (unless otherwise specified)
≤005PSI ≥015PSI
PARAMETERS MIN TYP MAX MIN TYP MAX UNITS NOTES
Span 50 100 150 75 100 150 mV 1
Zero Pressure Output -2.0 0 2.0 -1.0 0 1.0 mV 2
Pressure Non Linearity 1psi: -0.30 to 0.30
5psi: -0.20 to 0.20 -0.10 0.10 %Span 3
Pressure Hysteresis -0.10 ±0.02 0.10 -0.05 ±0.02 0.05 %Span
Repeatability ±0.02 ±0.02 %Span
Input Resistance 2.0 3.5 6.5 2.0 3.5 5.8 KΩ
Output Resistance 4.0 7.0 4.0 6.0 KΩ
Temperature Error – Span -1.0 1.0 -0.75 0.75 %Span 4
Temperature Error – Offset -1.0 1.0 15psi: -0.75 to 0.75
>15psi: -0.50 to 0.50 %Span 4
Thermal Hysteresis – Span -0.25 ±0.05 0.25 -0.25 ±0.05 0.25 %Span 4
Thermal Hysteresis – Offset -0.25 ±0.05 0.25 -0.25 ±0.05 0.25 %Span 4
Long Term Stability – Span ±0.10 ±0.10 %Span/Year
Long Term Stability – Offset ±0.25 ±0.10 %Span/Year
Supply Current 0.5 1.5 2.0 0.5 1.5 2.0 mA 5
Output Load Resistance 5 5 MΩ 6
Insulation Resistance (50Vdc) 50 50 MΩ 7
Output Noise (10Hz to 1KHz) 1.0 1.0 uV p-p
Response Time (10% to 90%) 0.1 0.1 ms
Pressure Overload 1psi: 10X max
5psi: 3X max 3X Rated
Pressure Burst 1psi: 12X max
5psi: 4X max 4X Rated 8
Compensated Temperature 1psi: 0 to 50
5psi: 0 to 70
-20 +85 °C
Operating Temperature -20 +70 -40 +125 ºC 9
Storage Temperature -50 +125 -50 +125 ºC 9
Media – Pressure Port Liquids and Gases compatible with 316/316L Stainless Steel
Media – Reference Port Compatible with Silicon, Pyrex, Gold, Fluorosilicone Rubber, and 316/316L
Stainless Steel
Notes
1. For amplified output circuits, 3.012V ±1% interchangeability with gain set resistor. See application schematic.
2. Measured at vacuum for absolute (A), ambient for gage (G).
3. Best fit straight line.
4. Over the compensated temperature range with respect to 25°C.
5. Guarantees output/input ratiometricity.
6. Load resistance to reduce measurement errors due to output loading.
7. Between case and sensing element.
8. The maximum pressure that can be applied to a transducer without rupture of either the sensing element or transducer.
9. Maximum temperature range for product with standard cable and connector is -20°C to +105°C.
154N Compensated www.meas-spec.com March 2011