High Performance Signal Conditioners DSCA
For information call 800-444-7644
150
DSCA45
Frequency Input Signal Conditioners
Description
Each DSCA45 frequency input module provides a single channel of frequency
input which is isolated and converted to a standard analog voltage or current
output (Figure 1).
The frequency input signal can be a TTL level or zero-crossing signal. Terminal
7 (-IN) on the field-side terminal block is the common or ground connection
for input signals. A TTL signal is connected from terminal 6 (+IN) to terminal 7
(-IN), while a zero-crossing signal is connected from terminal 5 (+EXC) to
terminal 7 (-IN). Input circuitry for each of the signal types has hysteresis built
in. An input signal must cross entirely through the hysteresis region in order to
trigger the threshold comparator.
A +5.1V excitation is available for use with magnetic pick-up or contact-closure
type sensors. The excitation is available on terminal 8 (-EXC) with return at
terminal 7 (-IN).
Module output is either voltage or current. For current output models a dedicated
loop supply is provided at terminal 3 (+OUT) with loop return located at terminal
4 (-OUT). The system-side load may be either floating or grounded.
Special input circuits provide protection against accidental connection of power-
line voltages up to 480VAC and against transient events as defined by ANSI/
IEEE C37.90.1-1989. Protection circuits are also present on the signal output
and power input terminals to guard against transient events and power reversal.
Signal and power lines are secured to the module using screw terminals which
are pluggable terminal blocks for ease of system assembly and reconfiguration.
DSCA45 modules have excellent stability over time and do not require
recalibration, however, both zero and span settings are adjustable to accom-
Figure 1: DSCA45 Block Diagram
Features
Accepts Frequency Inputs of 0 to 100kHz
Industry Standard Output of Either 0-10V,
0-20mA, or 4-20mA
±0.05% Factory Calibrated Accuracy
Adjustable Zero (±5%) and Span (±5%)
1500Vrms Transformer Isolation
Input Overload Protected to 240VAC
Continuous
ANSI/IEEE C37.90.1-1989 Transient
Protection
Mounts on Standard DIN Rail
CSA and FM Approvals Pending
CE Compliant
modate situations where fine tuning is desired. The adjustments are made using
potentiometers located under the front panel label and are non-interactive for
ease of use.
High Performance Signal Conditioners DSCA
Visit our website www.dataforth.com 151
Specifications
Input
Range 0 to 100kHz max
Threshold Zero Crossing
Minimum Input 60mVp-p
Maximum Input 350Vp-p
Minimum Pulse Width 4µs
TTL Input Low 0.8V max
TTL Input High 2.4V min
Hysteresis
Zero Crossing 40mV
TTL 1.5V
Resistance 100k
Protection
Continuous 240Vrms max
Transient ANSI/IEEE C37.90.1-1989
Output Range See Ordering Information
Adjustability ±5% Zero & Span
Load Resistance (IOUT) 600 max.
Current Limit 8mA (VOUT), 30mA (IOUT)
Output Protection
Short to Ground Continuous
Transient ANSI/IEEE C37.90.1-1989
Ripple <0.20% Span at input >2% Span
Accuracy(1) ±0.05% Span
vs. Temperature ±40ppm/°C (Zero & Span)
Nonlinearity ±0.02% Span
Isolation (Common Mode)
Input to Output, Input to Power
Continuous 1500Vrms max
Transient ANSI/IEEE C37.90.1-1989
Output to Power
Continuous 50VDC max
Rejection (50-60Hz Common Mode) 120dB
Response Time (0 to 90%)
DSCA45-01, -02, -03 310ms, 175ms, 50ms
DSCA45-04, -05, -06 30ms, 30ms, 10ms
DSCA45-07, -08 5ms, 1.5ms
Field Excitation +5.1V ±5% at 8mA max
Power Supply
Voltage 19 to 29VDC
Current 60mA (VOUT), 80mA (IOUT)
Sensitivity ±0.0002%/%
Protection
Reverse Polarity Continuous
Transient ANSI/IEEE C37.90.1-1989
Environmental
Operating & Storage Temp. Range -40°C to +80°C
Relative Humidity 0 to 95% noncondensing
Emissions EN50081-1, ISM Group 1,
Class A (Radiated, Conducted)
Immunity EN50082-1, ISM Group 1,
Class A (ESD, RF, EFT)
Mechanical Dimensions 2.95" x 0.89" x 4.13"
(h)(w)(d) (75mm x 22.5mm x 105mm)
Mounting DIN EN50022-35x7.5
or -35x15 rail
Module
Typical at TA=+25°C and +24V supply voltage
DSCA45
Ordering Information
Available
Model Input Range Output Range
DSCA45-01 0-500Hz 2, 3, 4
DSCA45-02 0-1kHz 2, 3, 4
DSCA45-03 0-2.5kHz 2, 3, 4
DSCA45-04 0-5kHz 2, 3, 4
DSCA45-05 0-10kHz 2, 3, 4
DSCA45-06 0-25kHz 2, 3, 4
DSCA45-07 0-50kHz 2, 3, 4
DSCA45-08 0-100kHz 2, 3, 4
NOTES:
(1) Includes nonlinearity, hysteresis and repeatability.
Output Range Part No. Suffix Example
1. -10V to +10V NONE N/A
2. 0V to +10V NONE DSCA45-01
3. 4 to 20mA C DSCA45-01C
4. 0 to 20mA E DSCA45-01E
Output Ranges Available